Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 38(2): 519-529, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38112878

RESUMO

This single blinded randomized controlled trial aims to assess whether the application of a Bayesian-adjusted CePROP (effect-site of propofol) advisory tool leads towards a more stringent control of the cerebral drug effect during anaesthesia, using qCON as control variable. 100 patients scheduled for elective surgery were included and randomized into a control or intervention group (1:1 ratio). In the intervention group the advisory screen was made available to the clinician, whereas it was blinded in the control group. The settings of the target-controlled infusion pumps could be adjusted at any time by the clinician. Cerebral drug effect was quantified using processed EEG (CONOX monitor, Fresenius Kabi, Bad Homburg, Germany). The time of qCON between the desired range (35-55) during anaesthesia maintenance was defined as our primary end point. Induction parameters and recovery times were considered secondary end points and coefficient of variance of qCON and CePROP was calculated in order to survey the extent of control towards the mean of the population. The desired range of qCON between 35 and 55 was maintained in 84% vs. 90% (p = 0.15) of the case time in the control versus intervention group, respectively. Secondary endpoints showed similar results in both groups. The coefficient of variation for CePROP was higher in the intervention group. The application of the Bayesian-based CePROP advisory system in this trial did not result in a different time of qCON between 35 and 55 (84 [21] vs. 90 [18] percent of the case time). Significant differences between groups were hard to establish, most likely due to a very high performance level in the control group. More extensive control efforts were found in the intervention group. We believe that this advisory tool could be a useful educational tool for novices to titrate propofol effect-site concentrations.


Assuntos
Propofol , Humanos , Propofol/farmacologia , Anestésicos Intravenosos/farmacologia , Teorema de Bayes , Anestesia Intravenosa , Alemanha , Eletroencefalografia
2.
Health Informatics J ; 28(3): 14604582221112855, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35801667

RESUMO

The credibility of threshold-based alarms in anesthesia monitors is low and most of the warnings they produce are not informative. This study aims to show that Machine Learning techniques have a potential to generate meaningful alarms during general anesthesia without putting constraints on the type of procedure. Two distinct approaches were tested - Complication Detection and Anomaly Detection. The former is a generic supervised learning problem and for this a simple feed-forward Neural Network performed best. For the latter, we used an Encoder-Decoder Long Short-Term Memory architecture that does not require a large manually-labeled dataset. We show this approach to be more flexible and in the spirit of Explainable Artificial Intelligence, offering greater potential for future improvement.


Assuntos
Anestesiologia , Inteligência Artificial , Anestesiologia/métodos , Humanos , Aprendizado de Máquina , Redes Neurais de Computação
3.
Anesthesiology ; 134(1): 35-51, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33064833

RESUMO

BACKGROUND: γ-Aminobutyric acid type A (GABAA) receptor agonists are known to cause involuntary muscle movements. The mechanism of these movements is not known, and its relationship to depth of anesthesia monitoring is unclear. We have explored the effect of involuntary muscle movement on the pharmacokinetic-pharmacodynamic model for the GABAA receptor agonist ABP-700 and its effects on the Bispectral Index (BIS) as well as the Modified Observer's Assessment of Alertness/Sedation (MOAA/S) scores. METHODS: Observations from 350 individuals (220 men, 130 women) were analyzed, comprising 6,312 ABP-700 concentrations, 5,658 ABP-700 metabolite (CPM-acid) concentrations, 25,745 filtered BIS values, and 6,249 MOAA/S scores, and a recirculatory model developed. Various subject covariates and pretreatment with an opioid or a benzodiazepine were explored as covariates. Relationships between BIS and MOAA/S models and involuntary muscle movements were examined. RESULTS: The final model shows that the pharmacokinetics of ABP-700 are characterized by small compartmental volumes and rapid clearance. The BIS model incorporates an effect-site for BIS suppression and a secondary excitatory/disinhibitory effect-site associated with a risk of involuntary muscle movements. The secondary effect-site has a threshold that decreases with age. The MOAA/S model did not show excitatory effects. CONCLUSIONS: The GABAA receptor agonist ABP-700 shows the expected suppressive effects for BIS and MOAA/S, but also disinhibitory effects for BIS associated with involuntary muscle movements and reduced by pretreatment. Our model provides information about involuntary muscle movements that may be useful to improve depth of anesthesia monitoring for GABAA receptor agonists.


Assuntos
Anestesia , Monitores de Consciência , Etomidato/análogos & derivados , Agonistas de Receptores de GABA-A/farmacologia , Imidazóis/farmacologia , Adulto , Algoritmos , Analgésicos Opioides , Benzodiazepinas , Sedação Consciente , Etomidato/farmacocinética , Feminino , Agonistas de Receptores de GABA-A/farmacocinética , Humanos , Imidazóis/farmacocinética , Masculino , Monitorização Intraoperatória , Músculo Liso/efeitos dos fármacos , Medicação Pré-Anestésica
4.
Anesth Analg ; 131(4): 1173-1183, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32925338

RESUMO

BACKGROUND: In the University Medical Center Groningen in Groningen, the Netherlands, moderate-to-deep sedation is provided by nursing staff trained and supervised by the anesthesia department using protocol-based target-controlled infusions (TCIs) of propofol and remifentanil. The aim of this retrospective cohort study was to investigate the incidence of events with potential adverse health consequences within this service model and the risk factors for the occurrence of these events. METHODS: We retrospectively interrogated a database containing the computerized anesthetic records of 2937 procedures where moderate-to-deep sedation was provided using TCI administration of propofol and remifentanil between May 2014 and October 2017. The primary outcome measures were the incidence of sedation-related events with potential adverse health consequences and risk factors for the occurrence of such events. The events under investigation were unplanned intensive care unit (ICU) admission, need for cardiopulmonary resuscitation (CPR), death on the day of the procedure due to sedation-related events, cardiovascular events (arrhythmias, hypertension, and hypotension), pulmonary events (aspiration, desaturation, unplanned tracheal intubation), anaphylactic or allergic reactions, and the termination of the procedure due to sedation-related events. Cardiovascular and pulmonary events were classified as severe, significant, or moderate. Events were identified by using computer algorithms to search the computerized records from all included procedures. RESULTS: Data from 2937 procedures were analyzed. No patients suffered catastrophic events (death, need for CPR, or unplanned ICU admission). Thirty-two severe sedation-related events occurred in 32 procedures. Severe desaturation (0.6%; 95% confidence interval [CI], 0.4-0.9) and severe hypertension (0.2%; 95% CI, 0.04-0.37) were the most common severe events. Significant hypotension (8.8%; 95% CI, 7.73-9.77) and significant desaturation (1.6%; 95% CI, 1.12-2.02) were found to be the most common events with potential adverse health consequences. No patient suffered lasting health consequences. Average mean and maximum targeted effect-site concentrations (Cet) for propofol were 2.6 ± 0.83 and 3.3 ± 1.09 µg·mL, respectively, and for remifentanil 0.84 ± 0.18 and 0.99 ± 0.22 ng·mL, respectively. Maximum Cets of propofol were lower among patients with higher body mass index (BMI) and were higher among patients of younger age. Higher BMI was a risk factor for desaturation. Increased age and lower BMI were risk factors for hypotension. Longer procedure time was a risk factor for both desaturation and hypotension. CONCLUSIONS: Moderate-to-deep sedation by propofol and remifentanil TCI has a low incidence of catastrophic and severe events.


Assuntos
Sedação Profunda/métodos , Hipnóticos e Sedativos , Propofol , Remifentanil , Idoso , Índice de Massa Corporal , Reanimação Cardiopulmonar , Estudos de Coortes , Cuidados Críticos , Sedação Profunda/efeitos adversos , Feminino , Cardiopatias/epidemiologia , Mortalidade Hospitalar , Humanos , Hipnóticos e Sedativos/administração & dosagem , Hipnóticos e Sedativos/efeitos adversos , Infusões Intravenosas , Pneumopatias/epidemiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Propofol/administração & dosagem , Propofol/efeitos adversos , Remifentanil/administração & dosagem , Remifentanil/efeitos adversos , Fatores de Risco
5.
Anesth Analg ; 129(2): 409-415, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30138170

RESUMO

BACKGROUND: Pulse oximetry-derived oxygen saturation is typically >97% in normoxia and hyperoxia, limiting its clinical use. The new Oxygen Reserve Index (ORi), a relative indicator of the partial pressure of oxygen dissolved in arterial blood (PaO2) in the range of 100-200 mm Hg, may allow additional monitoring of oxygen status. METHODS: In this prospective validation intervention study, 20 healthy volunteers were breathing standardized oxygen concentrations ranging from mild hypoxia (fraction of inspired oxygen = 0.14) to hyperoxia (fraction of inspired oxygen = 1.0) via a tight-fitting face mask. ORi was measured noninvasively by multiwavelength pulse co-oximetry using 2 finger sensors. These ORi values (unitless scale, 0.00-1.00) were compared with measured PaO2 values. Repeated-measurements correlation analysis was performed to assess the ORi/PaO2 relationship. ORi trending ability was assessed using a 4-quadrant plot. The area under the receiver operating characteristics curve was calculated to assess the prediction of hypoxia (low-ranged PaO2, <100 mm Hg). RESULTS: Within the ORi-sensitive range, a strong positive correlation was found between ORi and PaO2 for both sensors (R = 0.78 and 0.83; P < .0001). ORi trending of PaO2 was good within this range (concordance rate = 94%). The prediction of PaO2 <100 mm Hg was also good, with an area under the receiver operating characteristics curve of 0.91 and 99% sensitivity and 82% specificity. CONCLUSIONS: In this prospective volunteer validation study, a strong and positive correlation between PaO2 and ORi was found, together with a good trending ability. Based on these data, the future use of ORi as a continuous noninvasive monitoring tool for assessing oxygenation status in patients receiving supplemental oxygen might be supported.


Assuntos
Dedos/irrigação sanguínea , Oximetria , Oxigênio/sangue , Adolescente , Adulto , Biomarcadores/sangue , Feminino , Voluntários Saudáveis , Humanos , Masculino , Ensaios Clínicos Controlados não Aleatórios como Assunto , Pressão Parcial , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
6.
Anesthesiology ; 127(1): 20-35, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28459733

RESUMO

BACKGROUND: Cyclopropyl-methoxycarbonylmetomidate (ABP-700) is a new "soft" etomidate analog. The primary objectives of this first-in-human study were to describe the safety and efficacy of ABP-700 and to determine its maximum tolerated dose. Secondary objectives were to characterize the pharmacokinetics of ABP-700 and its primary metabolite (cyclopropyl-methoxycarbonyl acid), to assess the clinical effects of ABP-700, and to investigate the dose-response and pharmacokinetic/pharmacodynamic relationships. METHODS: Sixty subjects were divided into 10 cohorts and received an increasing, single bolus of either ABP-700 or placebo. Safety was assessed by clinical laboratory evaluations, infusion-site reactions, continuous monitoring of vital signs, physical examination, adverse event monitoring, and adrenocorticotropic hormone stimulation testing. Clinical effects were assessed with modified observer's assessment of alertness/sedation and Bispectral Index monitoring. Pharmacokinetic parameters were calculated. RESULTS: Stopping criteria were met at 1.00 mg/kg dose. No serious adverse events were reported. Adverse events were dose-dependent and comprised involuntary muscle movement, tachycardia, and ventilatory effects. Adrenocorticotropic hormone stimulation evoked a physiologic cortisol response in all subjects, no different from placebo. Pharmacokinetics were dose-proportional. A three-compartment pharmacokinetic model described the data well. A rapid onset of anesthesia/sedation after bolus administration and also a rapid recovery were observed. A quantitative concentration-effect relationship was described for the modified observer's assessment of alertness/sedation and Bispectral Index. CONCLUSIONS: This first-in-human study of ABP-700 shows that ABP-700 was safe and well tolerated after single-bolus injections up to 1.00 mg/kg. Bolus doses of 0.25 and 0.35 mg/kg were found to provide the most beneficial clinical effect versus side-effect profile.


Assuntos
Etomidato/análogos & derivados , Etomidato/farmacologia , Hipnóticos e Sedativos/farmacologia , Adolescente , Adulto , Relação Dose-Resposta a Droga , Método Duplo-Cego , Etomidato/administração & dosagem , Feminino , Humanos , Hipnóticos e Sedativos/administração & dosagem , Infusões Intravenosas , Masculino , Dose Máxima Tolerável , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
7.
Can J Anaesth ; 62(11): 1153-60, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26335905

RESUMO

BACKGROUND: Pulse pressure variation (PPV) and stroke volume variation (SVV) are dynamic preload variables that can be measured noninvasively to assess fluid responsiveness (FR) in anesthetized patients with mechanical ventilation. Few studies have examined the effectiveness of predicting FR according to the definition of FR, and assessment of inconclusive values of PPV and SVV around the cut-off value (the "grey zone") might improve individual FR prediction. We explored the ability of noninvasive volume clamp derived measurements of PPV and SVV to predict FR using the grey zone approach, and we assessed the influence of multiple thresholds on the predictive ability of the numerical definition of FR. METHODS: Ninety patients undergoing general surgery were included in this prospective observational study and received a 500 mL fluid bolus as deemed clinically required by the attending anesthesiologist. A minimal relative increase in stroke volume index (↑SVI) was used to define FR with different thresholds from 10-25%. The PPV, SVV, and SVI were measured using the Nexfin® device that employs noninvasive volume clamp plethysmography. RESULTS: The area under the receiver operator characteristic curve gradually increased for PPV / SVV with higher threshold values (from 0.818 / 0.760 at 10% ↑SVI to 0.928 / 0.944 at 25% ↑SVI). The grey zone limits of both PPV and SVV changed from 9-16% (PPV) and 5-13% (SVV) at the 10% ↑SVI threshold to 18-21% (PPV) and 14-16% (SVV) at the 25% ↑SVI threshold. CONCLUSION: Noninvasive PPV and SVV measurements allow an acceptable FR prediction, although the reliability of both variables is dependent on the intended increase in SVI, which improves substantially with concomitant smaller grey zones at higher ↑SVI thresholds.


Assuntos
Pressão Sanguínea/fisiologia , Hidratação , Volume Sistólico/fisiologia , Anestesia Geral , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Respiração Artificial , Procedimentos Cirúrgicos Operatórios
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA