1.
Eur J Clin Microbiol Infect Dis ; 43(3): 511-516, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38206519

RESUMO

PURPOSE: Rapid diagnosis and treatment of infectious meningitis and encephalitis (ME) is critical to minimize morbidity and mortality. Recently, Qiagen introduced the CE-IVD QIAstat-Dx ME panel (QS-ME) for syndromic diagnostic testing of meningitis and encephalitis. Some data on the performance of the QS-ME in comparison to the BioFire FilmArray ME panel are available. In this study, the performance of the QS-ME is compared to the current diagnostic workflow in two academic medical centers in the Netherlands. METHODS: A total of 110 cerebrospinal fluid samples were retrospectively tested with the QS-ME. The results obtained were compared to the results of laboratory-developed real-time PCR assays (LDTs), IS-pro, bacterial culture, and cryptococcal antigen (CrAg) testing. In addition, the accuracy of the QS-ME was also investigated using an external quality assessment (EQA) panel consisting of ten samples. RESULTS: Four of the 110 samples tested failed to produce a valid QS-ME result. In the remaining 106 samples, the QS-ME detected 53/53 viral targets, 38/40 bacterial targets, and 7/13 Cryptococcus neoformans targets. The discrepant bacterial results consisted of two samples that were previously tested positive for Listeria monocytogenes (CT 35.8) and Streptococcus pneumoniae (CT 40), respectively. The QS-ME detected one additional result, consisting of a varicella-zoster virus signal (CT 35.9), in a sample in which both techniques detected Streptococcus pyogenes. Finally, 100% concordance was achieved in testing a blinded bacterial ME EQA panel. CONCLUSION: The QS-ME is a relevant addition to the syndromic testing landscape to assist in diagnosing infectious ME.


Assuntos
Cryptococcus neoformans , Encefalite , Encefalite Infecciosa , Meningites Bacterianas , Meningite , Humanos , Estudos Retrospectivos , Fluxo de Trabalho , Reação em Cadeia da Polimerase Multiplex/métodos , Meningite/diagnóstico , Encefalite/líquido cefalorraquidiano , Meningites Bacterianas/diagnóstico , Bactérias
2.
J Virol Methods ; 298: 114291, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34562515

RESUMO

At the time SARS-CoV-2 was identified as the cause of coronavirus disease 2019 (COVID-19) no in vitro diagnostic (IVD) tests were available since it was a new virus. Very shortly after the release of the genomic sequence of SARS-CoV-2, laboratory-developed tests (LDTs) were developed, made available and implemented in several laboratories in the Netherlands and globally. In this study, the performance of an E-gene Sarbeco specific real-time reverse-transcriptase PCR (RT-PCR) was verified on the open modus of the geneLEAD VIII sample-to-answer platform. The results obtained from 134 clinical samples, of which 63 had been tested positive, showed almost complete concordance compared to the same PCR on the routine diagnostic systems and that was validated according to the national reference standard. The only discordant sample tested positive using the routine diagnostic workflow with a cycle threshold (CT) value of 37.7, while the sample tested negative using the geneLEAD VIII workflow. In addition, good performance was achieved in analyzing a blinded SARS-CoV-2 external quality assurance (EQA) panel. Implementation of the geneLEAD VIII platform as routine diagnostic tool resulted in testing 871 clinical samples with 115 positive results. In conclusion, the geneLEAD VIII SARS-CoV-2 workflow presented in this study showed excellent diagnostic performance and with a rapid turnaround time of approximately two hours it proved a valuable option for STAT SARS-CoV-2 testing in the absence of (rapid, CE-IVD) point-of-care testing platforms.


Assuntos
COVID-19 , SARS-CoV-2 , Teste para COVID-19 , Humanos , Testes Imediatos , Padrões de Referência , Sensibilidade e Especificidade
3.
J Clin Virol ; 135: 104720, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33418142

RESUMO

BACKGROUND: Apart from major health concerns associated to the SARS-coronavirus-2 (SARS-CoV-2) pandemic, also the diagnostic workflow encountered serious problems. Limited availability of kit components, buffers and even plastics has resulted in suboptimal testing procedures worldwide. Alternative workflows have been implemented to overcome these difficulties. Recently a liquid based sample prep has been launched as solution to overcome limitations in relation to nucleic acid extraction. OBJECTIVE: Multicenter evaluation of the QIAprep& Viral RNA UM kit (QIA P&A) for rapid sample preparation and real-time PCR detection of SARS-CoV-2 in comparison to standardized laboratory testing methods. STUDY DESIGN: Selected samples of the routine diagnostic workflow at Clinical Microbiology Laboratories of four Dutch hospitals have been subjected to the rapid QIA P&A protocol and the results have been compared to routine diagnostic data. RESULTS: Combining results of manual and automated procedures, a total of 377 clinical samples of which 202 had been tested positive with a wide range of CT values, showed almost complete concordance in the QIA P&A assay for samples up to CT values of 33 with one exception of CT 31. Prospectively 60 samples were tested and also showed 100 % concordance with 5 positives. The method has been automated by two centres. CONCLUSIONS: Despite an input of only 8 µL of clinical sample, the QIA P&A kit showed good performance for sample preparation and amplification of SARS-CoV-2 and can contribute as a rapid molecular testing strategy in managing the CoV-2 pandemic.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/virologia , Programas de Rastreamento/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , SARS-CoV-2/genética , Técnicas de Laboratório Clínico/métodos , Humanos , Técnicas de Diagnóstico Molecular/métodos , Pandemias/prevenção & controle , Estudos Prospectivos , Manejo de Espécimes/métodos , Fluxo de Trabalho