Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 188
Filtrar
1.
J Vasc Surg ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38604322

RESUMO

OBJECTIVE: The aim of this study was to update our earlier experience and to evaluate long-term outcomes of chimney endovascular aortic repair performed for selected cases with complex abdominal aortic aneurysm. METHODS: A single-center retrospective cohort study was conducted on 51 consecutive patients who underwent chimney endovascular aortic repair procedure, deemed unfit for open surgical repair and fenestrated endovascular aneurysm repair, from October 2009 to November 2019. Kaplan-Meier analyses were used to assess the estimated overall survival, freedom from aneurysm related mortality, freedom from reintervention, freedom from target vessel instability, and freedom from type Ia endoleaks. RESULTS: Fifty-one patients (mean age, 77.1 ± 7.5 years) with a mean preoperative maximum aneurysm diameter of 74.2 ± 20.1 mm were included. Mean follow-up duration was 48.6 months (range, 0-136 months). Estimated overall survival at 5 and 7 years was 36.3% ± 7.1% and 18.3% ± 6.0%, respectively. Freedom from aneurysm-related mortality was 88.6% ± 4.9% at 7 years. Estimated freedom from type Ia endoleaks at 7 years was 91.8% ± 3.9%. A total of 21 late reinterventions were performed in 17 patients (33%). Most of them were performed to treat type II endoleaks with sac growth (47.6%; n = 10) and type Ib endoleak (23.8%; n = 5). Estimated freedom from reintervention at 7 years was 56.3% ± 7.9%. Estimated freedom from target vessel instability at 7 years was 91.5% ± 4.1%. CONCLUSIONS: The 7-year results of chimney endovascular aortic repair procedures performed in our center confirm the long-term safety and effectiveness of this technique in a series of high-risk patients with large aneurysms. The present study has, to the best of our knowledge, the longest follow-up for patients treated with chimney endovascular aortic repair, and it provides data to the scarce literature on the long-term outcomes of this procedure, showing acceptable to good long-term results.

2.
J Vasc Surg ; 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38431064

RESUMO

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) for blunt thoracic aortic injury (BTAI) at high-volume hospitals has previously been associated with lower perioperative mortality, but the impact of annual surgeon volume on outcomes following TEVAR for BTAI remains unknown. METHODS: We analyzed Vascular Quality Initiative (VQI) data from patients with BTAI that underwent TEVAR between 2013 and 2023. Annual surgeon volumes were computed as the number of TEVARs (for any pathology) performed over a 1-year period preceding each procedure and were further categorized into quintiles. Surgeons in the first volume quintile were categorized as low volume (LV), the highest quintile as high volume (HV), and the middle three quintiles as medium volume (MV). TEVAR procedures performed by surgeons with less than 1-year enrollment in the VQI were excluded. Using multilevel logistic regression models, we evaluated associations between surgeon volume and perioperative outcomes, accounting for annual center volumes and adjusting for potential confounders, including aortic injury grade and severity of coexisting injuries. Multilevel models accounted for the nested clustering of patients and surgeons within the same center. Sensitivity analysis excluding patients with grade IV BTAI was performed. RESULTS: We studied 1321 patients who underwent TEVAR for BTAI (28% by LV surgeons [0-1 procedures per year], 52% by MV surgeons [2-8 procedures per year], 20% by HV surgeons [≥9 procedures per year]). With higher surgeon volume, TEVAR was delayed more (in <4 hours: LV: 68%, MV: 54%, HV: 46%; P < .001; elective (>24 hours): LV: 5.1%; MV: 8.9%: HV: 14%), heparin administered more (LV: 80%, MV: 81%, HV: 87%; P = .007), perioperative mortality appears lower (LV: 11%, MV: 7.3%, HV: 6.5%; P = .095), and ischemic/hemorrhagic stroke was lower (LV: 6.5%, MV: 3.6%, HV: 1.5%; P = .006). After adjustment, compared with LV surgeons, higher volume surgeons had lower odds of perioperative mortality (MV: 0.49; 95% confidence interval [CI], 0.25-0.97; P = .039; HV: 0.45; 95% CI, 0.16-1.22; P = .12; MV/HV: 0.50; 95% CI, 0.26-0.96; P = .038) and ischemic/hemorrhagic stroke (MV: 0.38; 95% CI, 0.18-0.81; P = .011; HV: 0.16; 95% CI, 0.04-0.61; P = .008). Sensitivity analysis found lower adjusted odds for perioperative mortality (although not significant) and ischemic/hemorrhagic stroke for higher volume surgeons. CONCLUSIONS: In patients undergoing TEVAR for BTAI, higher surgeon volume is independently associated with lower perioperative mortality and postoperative stroke, regardless of hospital volume. Future studies could elucidate if TEVAR for non-ruptured BTAI might be delayed and allow stabilization, heparinization, and involvement of a higher TEVAR volume surgeon.

3.
Eur J Vasc Endovasc Surg ; 67(2): 192-331, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38307694

RESUMO

OBJECTIVE: The European Society for Vascular Surgery (ESVS) has developed clinical practice guidelines for the care of patients with aneurysms of the abdominal aorta and iliac arteries in succession to the 2011 and 2019 versions, with the aim of assisting physicians and patients in selecting the best management strategy. METHODS: The guideline is based on scientific evidence completed with expert opinion on the matter. By summarising and evaluating the best available evidence, recommendations for the evaluation and treatment of patients have been formulated. The recommendations are graded according to a modified European Society of Cardiology grading system, where the strength (class) of each recommendation is graded from I to III and the letters A to C mark the level of evidence. RESULTS: A total of 160 recommendations have been issued on the following topics: Service standards, including surgical volume and training; Epidemiology, diagnosis, and screening; Management of patients with small abdominal aortic aneurysm (AAA), including surveillance, cardiovascular risk reduction, and indication for repair; Elective AAA repair, including operative risk assessment, open and endovascular repair, and early complications; Ruptured and symptomatic AAA, including peri-operative management, such as permissive hypotension and use of aortic occlusion balloon, open and endovascular repair, and early complications, such as abdominal compartment syndrome and colonic ischaemia; Long term outcome and follow up after AAA repair, including graft infection, endoleaks and follow up routines; Management of complex AAA, including open and endovascular repair; Management of iliac artery aneurysm, including indication for repair and open and endovascular repair; and Miscellaneous aortic problems, including mycotic, inflammatory, and saccular aortic aneurysm. In addition, Shared decision making is being addressed, with supporting information for patients, and Unresolved issues are discussed. CONCLUSION: The ESVS Clinical Practice Guidelines provide the most comprehensive, up to date, and unbiased advice to clinicians and patients on the management of abdominal aorto-iliac artery aneurysms.

4.
Catheter Cardiovasc Interv ; 103(3): 490-498, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38329195

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has changed the landscape of aortic stenosis (AS) management. AIM: To describe and evaluate geographic variation in AS treatment and outcomes among a sample of Medicare beneficiaries. METHODS: A retrospective analysis of administrative claims data was conducted on a 20% sample of Medicare fee-for-service beneficiaries aged 65 and older with a diagnosis of AS (2015-2018). Estimates of demographic, comorbidity, and healthcare resources were obtained from Medicare claims and the Dartmouth Atlas of Health Care at the hospital referral region (HRR), which represents regional tertiary medical care markets. Linear regression was used to explain HRR-level variation in rates of surgical aortic valve replacement (SAVR) and TAVR, and 1-year mortality and readmission rates. RESULTS: A total of 740,899 beneficiaries with AS were identified with a median prevalence of AS of 39.9 per 1000 Medicare beneficiary years. The average HRR-level rate of SAVR was 26.3 procedures per 1000 beneficiary years and the rate of TAVR was 20.3 procedures per 1000 beneficiary years. HRR-level comorbidities and number of TAVR centers were associated with a lower SAVR rate. Demographics and comorbidities explained most of the variation in HRR-level 1-year mortality (15.2% and 18.8%) and hospitalization rates (20.5% and 16.9%), but over half of the variation remained unexplained. CONCLUSION: Wide regional variation in the treatment and outcomes of AS was observed but were largely unexplained by patient factors and healthcare utilization. Understanding the determinants of AS treatment and outcomes can inform population health efforts for these patients.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Estados Unidos/epidemiologia , Medicare , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Constrição Patológica , Fatores de Risco
5.
JTCVS Open ; 17: 37-46, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420559

RESUMO

Objective: The relationship among increased aortic arch angulation, aortic flow dynamics, and vessel wall stiffness remains unclear. This experimental ex vivo study investigated how increased aortic arch angulation affects aortic stiffness and stent-graft induced aortic stiffening, assessed by pulse wave velocity (PWV). Methods: Porcine thoracic aortas were connected to a circulatory mock loop in a Type I and Type III aortic arch configuration. Baseline characteristics and blood pressures were measured. Proximal and distal flow curves were acquired to calculate PWV in both arch configurations. After that, a thoracic stent-graft (VAMF2626C100TU) was deployed in aortas with adequate proximal landing zone diameters to reach 10% t0 20% oversizing. Acquisitions were repeated for both arch configurations after stent-graft deployment. Results: Twenty-four aortas were harvested, surgically prepared, and mounted. Cardiac output was kept constant for both arch configurations (Type I: 4.74 ± 0.40 and Type III: 4.72 ± 0.38 L/minute; P = .703). Compared with a Type I arch, aortic PWV increased significantly in the Type III arch (3.53 ± 0.40 vs 3.83 ± 0.40 m/second; P < .001), as well as blood pressures. A stent-graft was deployed in 15 aortas. After deployment, Type I arch PWV increased (3.55 ± 0.39 vs 3.81 ± 0.44 m/second; P < .001) and Type III arch PWV increased although not significantly (3.86 ± 0.42 vs 4.03 ± 0.46 m/second; P = .094). Type III arch PWV resulted the highest and significantly higher compared with the Type I arch after stent-graft deployment (3.81 ± 0.44 vs 4.03 ± 0.46 m/second; P = .023). Conclusions: Increased aortic arch angulation-as in a Type III arch-is associated with higher aortic PWV and blood pressures and this may negatively influence cardiovascular health.

6.
Eur J Vasc Endovasc Surg ; 67(4): 594-600, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37925100

RESUMO

OBJECTIVE: The increasing number of endovascular procedures has resulted in an increasing radiation burden, particularly for the treatment team. Fiber Optic RealShape (FORS) technology uses laser light instead of fluoroscopy to visualise the endovascular guidewire and catheters. These devices can be used during the navigational part of procedures, such as cannulation of the contralateral limb (CL) in endovascular aneurysm repair (EVAR). The aim of this study was to describe the effect of using FORS on radiation dose during CL cannulation in standard EVAR. METHODS: This was a non-randomised, retrospective comparison study of prospectively collected, single centre data from FORS guided EVAR compared with a conventional fluoroscopy only guided EVAR cohort. A total of 27 FORS guided cases were matched 1:1 based on sex, age, and body mass index (BMI) with 27 regular (fluoroscopy only) EVARs. This study primarily focused on (1) technical success of FORS and (2) navigation time and radiation dose (cumulative air kerma [CAK], air kerma area product [KAP], and fluoroscopy time [FT]) during cannulation of the CL. In addition, overall procedure time and radiation dose of the complete EVAR procedure were studied. RESULTS: In 22 (81%) of the 27 FORS guided cases the CL was successfully cannulated using FORS. All radiation dose parameters were significantly lower in the FORS group (CAK, p < .001; KAP, p = .009; and FT, p < .001) for an equal navigation time (p = .95). No significant differences were found when comparing outcomes of the complete procedure. CONCLUSION: Use of FORS technology significantly reduces radiation doses during cannulation of the CL in standard EVAR.

7.
Ann Vasc Surg ; 98: 115-123, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37356660

RESUMO

BACKGROUND: To investigate associations between patient characteristics, intraprocedural complexity factors, and radiation exposure to patients during endovascular abdominal aortic aneurysm repair (EVAR). METHODS: Elective standard EVAR procedures between January 2015 and December 2020 were retrospectively analyzed. Patient characteristics and intraprocedural data (i.e., type of device, endograft configuration, additional procedures, and contralateral gate cannulation time [CGCT]) were collected. Dose area product (DAP) and fluoroscopy time were considered as measurements of radiation exposure. Furthermore, effective dose (ED) and doses to internal organs were calculated using PCXMC 2.0 software. Descriptive statistics, univariable, and multivariable linear regression were applied to investigate predictors of increased radiation exposure. RESULTS: The 99 patients were mostly male (90.9%) with a mean age of 74 ± 7 years. EVAR indications were most frequently abdominal aortic aneurysm (93.9%), penetrating aortic ulceration (2.0%), focal dissection (2.0%), or subacute rupture of infrarenal abdominal aortic aneurysm (2.0%). Median fluoroscopy time was 19.6 minutes (interquartile range [IQR], 14.1-29.4) and median DAP was 86,311 mGy cm2 (IQR, 60,160-130,385). Median ED was 23.2 mSv (IQR, 17.0-34.8) for 93 patients (93.9%). DAP and ED were positively correlated with body mass index (BMI) and CGCT. Kidneys, small intestine, active bone marrow, colon, and stomach were the organs that received the highest equivalent doses during EVAR. Higher DAP and ED values were observed using the Excluder endograft, other bi- and tri-modular endografts, and EVAR with ≥2 additional procedures. Multivariable linear regression analysis revealed that BMI, ≥2 additional procedures during EVAR, and CGCT were independent positive predictors of DAP and ED levels after accounting for endograft type. CONCLUSIONS: Patient-related and procedure-related factors such as BMI, ≥2 additional procedures during EVAR, and CGCT resulted predictors of radiation exposure for patients undergoing EVAR, as quantified by higher DAP and ED levels. The main intraprocedural factor that increased radiation exposure was CGCT. These data can be of importance for better managing radiation exposure during EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Exposição à Radiação , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Exposição à Radiação/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Implante de Prótese Vascular/efeitos adversos , Doses de Radiação , Fatores de Risco
8.
J Endovasc Ther ; : 15266028231210228, 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37936418

RESUMO

OBJECTIVE: In many studies on aortic disease, women are underrepresented. The present study aims to assess sex-specific morphometric differences and gain more insight into endovascular treatment of the ascending aorta (AA) and arch. METHODS: Electrocardiogram-gated cardiac computed tomography scans of 116 consecutive patients who were evaluated for transcatheter aortic valve replacement were retrospectively reviewed. Measurements of the AA and aortic arch were made in multiplanar views, perpendicular to the semi-automatic centerline. Multiple linear regression analysis was performed to identify predictors affecting AA and aortic arch diameter in men and women. Propensity score matching was used to investigate whether sex influences aortic morphology. RESULTS: In both sexes, body surface area (BSA) was identified as a positive predictor and diabetes as a negative predictor for aortic diameters. In men, age was identified as a positive predictor and smoking as a negative predictor for aortic diameters. Propensity score matching identified 40 pairs. Systolic and diastolic mean diameters and AA length were significantly wider in men. On average, male aortas were 7.4% wider than female aortas, both in systole and diastole. CONCLUSIONS: The present analysis demonstrates that, in women, increased BSA is associated with increased aortic arch diameters, while diabetes is associated with decreased AA and arch diameters. In men, increased BSA and age are associated with increased AA and arch diameters, while smoking and diabetes are associated with decreased AA and arch diameters. Men were confirmed to have 7.4% greater AA and arch diameters than women. CLINICAL IMPACT: Men had 7.4% greater ascending aorta and arch diameters than women in a retrospective cohort, gated computed tomography-based study of 116 patients. Sex-specific differences in ascending aortic and arch size should be considered by aortic endovascular device manufacturers and physicians when developing ascending and arch endografts and planning aortic interventions.

9.
Nat Genet ; 55(11): 1831-1842, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37845353

RESUMO

Abdominal aortic aneurysm (AAA) is a common disease with substantial heritability. In this study, we performed a genome-wide association meta-analysis from 14 discovery cohorts and uncovered 141 independent associations, including 97 previously unreported loci. A polygenic risk score derived from meta-analysis explained AAA risk beyond clinical risk factors. Genes at AAA risk loci indicate involvement of lipid metabolism, vascular development and remodeling, extracellular matrix dysregulation and inflammation as key mechanisms in AAA pathogenesis. These genes also indicate overlap between the development of AAA and other monogenic aortopathies, particularly via transforming growth factor ß signaling. Motivated by the strong evidence for the role of lipid metabolism in AAA, we used Mendelian randomization to establish the central role of nonhigh-density lipoprotein cholesterol in AAA and identified the opportunity for repurposing of proprotein convertase, subtilisin/kexin-type 9 (PCSK9) inhibitors. This was supported by a study demonstrating that PCSK9 loss of function prevented the development of AAA in a preclinical mouse model.


Assuntos
Aneurisma da Aorta Abdominal , Estudo de Associação Genômica Ampla , Humanos , Animais , Camundongos , Pró-Proteína Convertase 9/genética , Pró-Proteína Convertase 9/metabolismo , Subtilisina , Pró-Proteína Convertases , Aneurisma da Aorta Abdominal/genética
10.
Ann Vasc Surg ; 94: 22-31, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37534575

RESUMO

BACKGROUND: This review aims to comprehensively summarize access challenges in thoracic endovascular aortic repair (TEVAR) by describing vascular access routes, associated risks, outcomes, and complications. METHODS: A literature search was conducted utilizing the PubMed (Medline), Scopus, and Web of Science databases. Qualitative and quantitative data from selected studies are extracted and discussed according to available standards for narrative reviews. RESULTS: In total, there were 109 eligible studies based on predefined inclusion- and exclusion criteria. There were 39 original articles or reviews and 57 case series or case reports. This article summarizes the evidence from these studies and discusses traditional retrograde access routes and techniques for TEVAR via a femoral or iliac route, with or without the use of conduits. Next, alternative antegrade access routes and techniques via a brachial, axillary, carotid, ascending aorta, transapical, transcaval, or another route are discussed. Vascular access complications are presented with specific attention to the importance of gender and alternative antegrade access routes. CONCLUSIONS: Multiple access routes and techniques are currently available to overcome access challenges associated with TEVAR, based on low grade evidence from heterogeneous studies. Future research that compares different access routes and techniques might help in the development of a tailored access protocol for specific patients with challenging TEVAR access.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Correção Endovascular de Aneurisma , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Aorta/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Estudos Retrospectivos
11.
J Vasc Surg Cases Innov Tech ; 9(3): 101269, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37635740

RESUMO

Numerical simulations of thoracic endovascular aortic repair (TEVAR) may be implemented in the preoperative workflow if credible and reliable. We present the application of a TEVAR simulation methodology to an 82-year-old woman with a penetrating atherosclerotic ulcer in the left hemiarch, that underwent a left common carotid artery to left subclavian artery bypass and consequent TEVAR in zone 2. During the intervention, kinking of the distal thoracic stent graft occurred and the simulation was able to reproduce this event. This report highlights the potential and reliability of TEVAR simulations to predict perioperative adverse events and short-term postoperative technical results.

12.
Eur J Vasc Endovasc Surg ; 66(5): 620-631, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37331424

RESUMO

OBJECTIVE: To assess which ultrasound (US) method of maximum anteroposterior (AP) abdominal aortic diameter measurement can be considered most reproducible. DATA SOURCES: MEDLINE, Scopus, and Web of Science were searched (PROSPERO ID: 276694). Eligible studies reported intra- and or interobserver agreement according to Bland-Altman analysis (mean ± standard deviation [SD]) for abdominal aortic diameter AP US evaluations with an outer to outer (OTO), inner to inner (ITI), and or leading edge to leading edge (LELE) calliper placement. REVIEW METHODS: The Preferred Reporting Items for a Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies statement was followed. The QUADAS-2 tool and QUADAS-C extension were used for risk of bias assessment and the GRADE framework to rate the certainty of evidence. Pooled estimates (fixed effects meta-analysis, after a test of homogeneity of means) for each US method were compared with pairwise one sided t tests. Sensitivity analyses (for studies published in 2010 or later) and meta-regression were also performed. RESULTS: 21 studies were included in the qualitative analysis. Twelve were eligible for quantitative analysis. Studies showed heterogeneity in the US model and transducer used, sex of participants, and observer professions, expertise, and training. Included studies shared a common mean for each US method (OTO: p = 1.0, ITI: p = 1.0, and LELE: p = 1.0). A pooled estimate of interobserver reproducibility for each US method was obtained, combining the mean ± SD (Bland-Altman analysis) from each study: OTO: 0.182 ± 0.440; ITI: 0.170 ± 0.554; and LELE: 0.437 ± 0.419. There were no statistically significant differences between the methods (OTO vs. ITI: p = .52, OTO vs. LELE: p = .069, ITI vs. LELE: p = .17). Considering studies published in 2010 and later, the pooled estimate for LELE was the smallest, without statistically significant differences between the methods. Despite the low risk of bias, the certainty of the evidence for both meta-analysed outcomes remained low. CONCLUSION: The interobserver reproducibility for OTO and ITI was 2.5 times smaller (indicating better reproducibility) than LELE; however, without statistically significant differences between the methods and low GRADE evidence certainty. Additional data are needed to validate these findings, while inherent differences between the methods need to be emphasised.

13.
Eur J Vasc Endovasc Surg ; 66(6): 784-796, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37330201

RESUMO

OBJECTIVE: Pre-procedural planning of thoracic endovascular aortic repair (TEVAR) may implement computational adjuncts to predict technical and clinical outcomes. The aim of this scoping review was to explore the currently available TEVAR procedure and stent graft modelling options. DATA SOURCES: PubMed (MEDLINE), Scopus, and Web of Science were systematically searched (English language, up to 9 December 2022) for studies presenting a virtual thoracic stent graft model or TEVAR simulation. REVIEW METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews (PRISMA-ScR) was followed. Qualitative and quantitative data were extracted, compared, grouped, and described. Quality assessment was performed using a 16 item rating rubric. RESULTS: Fourteen studies were included. Among the currently available in silico simulations of TEVAR, severe heterogeneity exists in study characteristics, methodological details, and evaluated outcomes. Ten studies (71.4%) were published during the last five years. Eleven studies (78.6%) included heterogeneous clinical data to reconstruct patient specific aortic anatomy and disease (e.g., type B aortic dissection, thoracic aortic aneurysm) from computed tomography angiography imaging. Three studies (21.4%) constructed idealised aortic models with literature input. The applied numerical methods consisted of computational fluid dynamics analysing aortic haemodynamics in three studies (21.4%) and finite element analysis analysing structural mechanics in the others (78.6%), including or excluding aortic wall mechanical properties. The thoracic stent graft was modelled as two separate components (e.g., graft, nitinol) in 10 studies (71.4%), as a one component homogenised approximation (n = 3, 21.4%), or including nitinol rings only (n = 1, 7.1%). Other simulation components included the catheter for virtual TEVAR deployment and numerous outcomes (e.g., Von Mises stresses, stent graft apposition, drag forces) were evaluated. CONCLUSION: This scoping review identified 14 severely heterogeneous TEVAR simulation models, mostly of intermediate quality. The review concludes there is a need for continuous collaborative efforts to improve the homogeneity, credibility, and reliability of TEVAR simulations.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Correção Endovascular de Aneurisma , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Stents , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Reprodutibilidade dos Testes , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Complicações Pós-Operatórias/cirurgia , Resultado do Tratamento , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Estudos Retrospectivos
14.
J Vis Exp ; (194)2023 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-37154545

RESUMO

Vascular surgeons and interventional radiologists face chronic exposure to low-dose radiation during endovascular procedures, which may impact their health in the long term due to their stochastic effects. The presented case shows the feasibility and efficacy of combining Fiber Optic RealShape (FORS) technology and intravascular ultrasound (IVUS) to reduce operator exposure during the endovascular treatment of obstructive peripheral arterial disease (PAD). FORS technology enables real-time, three-dimensional visualization of the full shape of guidewires and catheters, embedded with optical fibers that use laser light instead of fluoroscopy. Hereby, radiation exposure is reduced, and spatial perception is improved while navigating during endovascular procedures. IVUS has the capacity to optimally define vessel dimensions. Combining FORS and IVUS in a patient with iliac in-stent restenosis, as shown in this case report, enables passage of the stenosis and pre- and post-percutaneous transluminal angioplasty (PTA) plaque assessment (diameter improvement and morphology), with a minimum dose of radiation and zero contrast agent. The aim of this article is to describe the method of combining FORS and IVUS stepwise, to show the potential of merging both techniques in view of reducing radiation exposure and improving navigation tasks and treatment success during the endovascular procedure for the treatment of PAD.


Assuntos
Angioplastia com Balão , Arteriopatias Oclusivas , Procedimentos Endovasculares , Doença Arterial Periférica , Exposição à Radiação , Humanos , Ultrassonografia de Intervenção/métodos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Tecnologia , Stents
15.
EJVES Vasc Forum ; 59: 8-14, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37213485

RESUMO

Objective: Little is known about the cardiovascular changes after TEVAR and regarding the impact on aortic stiffness for different stent graft generations specifically, following changes in device design. The present study evaluated the stent graft induced aortic stiffening of two generations of the Valiant thoracic aortic stent graft. Methods: This was an ex vivo porcine investigation using an experimental mock circulatory loop. Thoracic aortas of young healthy pigs were harvested and connected to the mock circulatory loop. At a 60 bpm heart rate and stable mean arterial pressure, baseline aortic characteristics were obtained. Pulse wave velocity (PWV) was calculated before and after stent graft deployment. Paired and independent sample t tests or their non-parametric alternatives were performed to test for differences where appropriate. Results: Twenty porcine thoracic aortas were divided into two equal subgroups, in which a Valiant Captivia or a Valiant Navion stent graft was deployed. Both stent grafts were similar in diameter and length. Baseline aortic characteristics did not differ between the subgroups. Mean arterial pressure values did not change after either stent graft, while pulse pressures increased statistically significantly after Captivia (mean 44 ± 10 mmHg to 51 ± 13 mmHg, p = .002) but not after Navion. Mean baseline PWV increased after both Captivia (4.4 ± 0.6 m/s to 4.8 ± 0.7 m/s, p = .007) and Navion (4.6 ± 0.7 m/s to 4.9 ± 0.7 m/s, p = .002). There was no statistically significant difference in the mean percentage increase in PWV for either subgroup (8 ± 4% vs. 6 ± 4%, p = .25). Conclusion: These experimental findings showed no statistically significant difference in the percentage increase of aortic PWV after either stent graft generation and confirm that TEVAR increases aortic PWV. As a surrogate for aortic stiffness, this calls for further improvements in future thoracic aortic stent graft designs regarding device compliance.

16.
PLoS One ; 18(4): e0281811, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37036876

RESUMO

IMPORTANCE: Aortic stenosis (AS) is one of the most common heart valve conditions and its incidence and prevalence increases with age. With the introduction of transcatheter aortic valve replacement (TAVR), racial and ethnic disparities in AS diagnosis, treatment and outcomes is poorly understood. OBJECTIVE: In this study we assessed racial and ethnic disparities in AS diagnosis, treatment, and outcomes among Medicare beneficiaries. DESIGN: We conducted a population-based cohort study of inpatient, outpatient, and professional claims from a 20% sample of Medicare beneficiaries. MAIN OUTCOMES AND MEASURES: Incidence and Prevalence was determined among Medicare Beneficiaries. Outcomes in this study included management; the number of (non)-interventional cardiology and cardiothoracic surgery evaluation and management (E&M) visits, and number of transthoracic echocardiograms (TTE) performed. Treatment, which was defined as Surgical Aortic Valve Replacement and Transthoracic Aortic Valve Replacement. And outcomes described as All-cause Hospitalizations, Heart Failure Hospitalization and 1-year mortality. RESULTS: A total of 1,513,455 Medicare beneficiaries were diagnosed with AS (91.3% White, 4.5% Black, 1.1% Hispanic, 3.1% Asian and North American Native) between 2010 and 2018. Annual prevalence of AS diagnosis was lower for racial and ethnic minorities compared with White patients, with adjusted rate ratios of 0.66 (95% CI 0.65 to 0.68) for Black patients, 0.67 (95% CI 0.64 to 0.70) for Hispanic patients and 0.75 (95% CI 0.73 to 0.77) for Asian and North American Native patients as recent as 2018. After adjusting for age, sex and comorbidities, cardiothoracic surgery E&M visits and treatment rates were significantly lower for Black, Hispanic and Asian and North American Native patients compared with White patients. All-cause hospitalization rate was higher for Black and Hispanic patients compared with White patient. 1-year mortality was higher for Black patients, while Hispanic and Asian and North American Native patients had lower 1-year mortality compared with White patients. CONCLUSIONS AND RELEVANCE: We demonstrated significant racial and ethnic disparities in the diagnosis, management and outcomes of AS. The factors driving the persistence of these disparities in AS care need to be elucidated to develop an equitable health care system.


Assuntos
Estenose da Valva Aórtica , Etnicidade , Disparidades em Assistência à Saúde , Grupos Raciais , Idoso , Humanos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Medicare , Estados Unidos/epidemiologia
18.
Diagnostics (Basel) ; 13(3)2023 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-36766601

RESUMO

To what extent the stentgraft design of iliac branch devices (IBDs) relates to dynamic deformation is currently unknown. Therefore, this study aimed to quantify and compare displacement and geometry changes during the cardiac cycle of two common IBDs. This paper presents a two-center trial with patients treated with a Zenith bifurcated iliac side (ZBIS) or Gore iliac branch endoprosthesis (IBE). All patients underwent a retrospective electrocardiogram (ECG)-gated computed tomographic angiography (CTA) during follow-up. Cardiac-pulsatility-induced displacement was quantified for the following locations: (neo) bifurcation of the aorta, IBD flow divider, distal markers of the internal iliac artery (IIA) component and first IIA bifurcation. Geometrical parameters (length, tortuosity index, curvature and torsion) were quantified over centerlines. Displacement was more pronounced for the IBE than the ZBIS, e.g., craniocaudal displacement of 0.91 mm (0.91-1.13 mm) vs. 0.57 mm (0.40-0.75 mm, p = 0.004), respectively. The IBDs demonstrated similar geometrical parameters in the neo-common iliac artery and distal IIA, except for the larger dynamic curvature and torsion of the distal IIA in IBEs. The IBEs showed more dynamic length and curvature change compared to the ZBIS in the stented IIA. The IIA trajectory showed more pronounced deformation during the cardiac cycle after placement of an IBE than a ZBIS, suggesting the IBE is more conformable than the ZBIS.

19.
Semin Thorac Cardiovasc Surg ; 35(1): 19-30, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35091051

RESUMO

We performed a contemporary assessment of clinical and radiographic factors of stroke after thoracic endovascular aortic repair (TEVAR). Patients undergoing TEVAR from 2006 to 2017 were identified. We assessed clinical and radiographic data, including preoperative head and neck computed tomography, Doppler ultrasonography, and intraoperative angiography. Our primary outcome was stroke after TEVAR. Four hundred seventy-nine patients underwent TEVAR, mean age 68.1 ± 19.5 years, 52.6% male. Indications for TEVAR included aneurysms (n = 238, 49.7%) or dissections (n = 152, 31.7%). Ishimaru landing zones were Zone 2 (n = 225, 47.0%), Zone 3 (n = 151, 31.5%), or Zone 4 (n = 103, 21.5%). Stroke occurred in 3.8% (n = 18) of patients, with 1.9% (8) major events (modified Rankin Scale >3). Pathophysiology was predominantly embolic (n = 14), and occurred in posterior (n = 6), anterior (n = 6), or combined circulation (n = 4), and in the left hemisphere (n = 10) or bilateral (n = 6). Univariate analysis suggested use of lumbar drain (33.3% versus 57.2%, P = 0.04), inability to revascularize the left subclavian artery (16.7% vs 5.2%, P = 0.04) and number of implanted components (2.5 ± 1.2 vs 2.0 ± 0.97, P = 0.03) were associated with stroke. Multivariable analysis identified number of implanted components (OR 1.7, 95%CI 1.17-2.67 P = 0.00) and inability to revascularize the left subclavian artery as independent predictors of stroke. Stroke was associated with a higher perioperative mortality (27.8% vs 3.9%, P < 0.01). Stroke after TEVAR is primarily embolic in nature and related to both anatomic and procedural factors. This may have important implications for device development in the era of endovascular arch repair.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Aorta Torácica/cirurgia , Acidente Vascular Cerebral/etiologia , Aortografia/métodos , Estudos Retrospectivos , Aneurisma da Aorta Torácica/cirurgia
20.
J Endovasc Ther ; 30(3): 419-432, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35311414

RESUMO

PURPOSE: Octogenarians are known to have less-favorable outcomes following ruptured abdominal aortic aneurysm (rAAA) repair compared with their younger counterparts. Accurate information regarding perioperative outcomes following rAAA-repair is important to evaluate current treatment practice. The aim of this study was to evaluate perioperative outcomes of octogenarians and to identify factors associated with mortality and major complications after open surgical repair (OSR) or endovascular aneurysm repair (EVAR) of a rAAA using nationwide, real-world, contemporary data. METHODS: All patients that underwent EVAR or OSR of an infrarenal or juxtarenal rAAA between January 1, 2013, and December 31, 2018, were prospectively registered in the Dutch Surgical Aneurysm Audit (DSAA) and included in this study. The primary outcome was the comparison of perioperative outcomes of octogenarians versus non-octogenarians, including adjustment for confounders. Secondary outcomes were the identification of factors associated with mortality and major complications in octogenarians. RESULTS: The study included 2879 patients, of which 1146 were treated by EVAR (382 octogenarians, 33%) and 1733 were treated by OSR (410 octogenarians, 24%). Perioperative mortality of octogenarians following EVAR was 37.2% versus 14.8% in non-octogenarians (adjusted OR=2.9, 95% CI=2.8-3.0) and 50.0% versus 29.4% following OSR (adjusted OR=2.2, 95% CI=2.2-2.3). Major complication rates of octogenarians were 55.4% versus 31.8% in non-octogenarians following EVAR (OR=2.7, 95% CI=2.1-3.4), and 68% versus 49% following OSR (OR=2.2, 95% CI=1.8-2.8). Following EVAR, 30.6% of the octogenarians had an uncomplicated perioperative course (UPC) versus 49.5% in non-octogenarians (OR=0.5, 95% CI=0.4-0.6), while following OSR, UPC rates were 20.7% in octogenarians versus 32.6% in non-octogenarians (OR=0.5, 95% CI=0.4-0.7). Cardiac or pulmonary comorbidity and loss of consciousness were associated with mortality and major complications in octogenarians. Interestingly, female octogenarians had lower mortality rates following EVAR than male octogenarians (adjusted OR=0.7, 95% CI=0.6-0.8). CONCLUSION: Based on this nationwide study with real-world registry data, mortality rates of octogenarians following ruptured AAA-repair were high, especially after OSR. However, a substantial proportion of these octogenarians following OSR and EVAR had an uneventful recovery. Known preoperative factors do influence perioperative outcomes and reflect current treatment practice.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Feminino , Fatores de Risco , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Ruptura Aórtica/etiologia , Complicações Pós-Operatórias/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA