Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Neurol ; : e16433, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39109842

RESUMO

BACKGROUND: Neurobehavioural comorbidities have a detrimental effect on the quality of life of people with epilepsy, yet tracking their impact is challenging as behaviour may vary with seizures and anti-seizure medication (ASM) side effects. Smartphones have the potential to monitor day-to-day neurobehavioural patterns objectively. We present the case of a man in his late twenties with drug-resistant focal epilepsy in whom we ascertained the effects of ASM withdrawal and a convulsive seizure on his touchscreen interactions. METHODS: Using a dedicated app, we recorded over 185 days the timestamps of 718,357 interactions. We divided the various smartphone behaviours according to the next-interval dynamics of the interactions by using a joint interval distribution (JID). During two ASM load transitions, namely before versus during tapering and tapering versus restarting medication, we used cluster-based permutation tests to compare the JIDs. We also compared the JID of the seizure day to the average of the previous 3 days. RESULTS: The cluster-based permutation tests revealed significant differences, with accelerated next-interval dynamics during tapering and a reversal upon medication restart. The day of the convulsion exhibited a marked slowing of next-interval dynamics compared to the preceding 3 days. CONCLUSION: Our findings suggest that the temporal dynamics of smartphone touchscreen interactions may help monitor neurobehavioural comorbidities in neurological care.

2.
Physiol Meas ; 45(5)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38697210

RESUMO

Objective.Electrical impedance tomography (EIT) produces clinical useful visualization of the distribution of ventilation inside the lungs. The accuracy of EIT-derived parameters can be compromised by the cardiovascular signal. Removal of these artefacts is challenging due to spectral overlapping of the ventilatory and cardiovascular signal components and their time-varying frequencies. We designed and evaluated advanced filtering techniques and hypothesized that these would outperform traditional low-pass filters.Approach.Three filter techniques were developed and compared against traditional low-pass filtering: multiple digital notch filtering (MDN), empirical mode decomposition (EMD) and the maximal overlap discrete wavelet transform (MODWT). The performance of the filtering techniques was evaluated (1) in the time domain (2) in the frequency domain (3) by visual inspection. We evaluated the performance using simulated contaminated EIT data and data from 15 adult and neonatal intensive care unit patients.Main result.Each filter technique exhibited varying degrees of effectiveness and limitations. Quality measures in the time domain showed the best performance for MDN filtering. The signal to noise ratio was best for DLP, but at the cost of a high relative and removal error. MDN outbalanced the performance resulting in a good SNR with a low relative and removal error. MDN, EMD and MODWT performed similar in the frequency domain and were successful in removing the high frequency components of the data.Significance.Advanced filtering techniques have benefits compared to traditional filters but are not always better. MDN filtering outperformed EMD and MODWT regarding quality measures in the time domain. This study emphasizes the need for careful consideration when choosing a filtering approach, depending on the dataset and the clinical/research question.


Assuntos
Artefatos , Impedância Elétrica , Processamento de Sinais Assistido por Computador , Tomografia , Humanos , Tomografia/métodos , Razão Sinal-Ruído , Adulto , Análise de Ondaletas , Sistema Cardiovascular , Recém-Nascido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA