Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Nucl Med ; 65(4): 600-606, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38485272

RESUMO

Because of the limited axial field of view of conventional PET scanners, the internal carotid arteries are commonly used to obtain an image-derived input function (IDIF) in quantitative brain PET. However, time-activity curves extracted from the internal carotids are prone to partial-volume effects due to the limited PET resolution. This study aimed to assess the use of the internal carotids for quantifying brain glucose metabolism before and after partial-volume correction. Methods: Dynamic [18F]FDG images were acquired on a 106-cm-long PET scanner, and quantification was performed with a 2-tissue-compartment model and Patlak analysis using an IDIF extracted from the internal carotids. An IDIF extracted from the ascending aorta was used as ground truth. Results: The internal carotid IDIF underestimated the area under the curve by 37% compared with the ascending aorta IDIF, leading to Ki values approximately 17% higher. After partial-volume correction, the mean relative Ki differences calculated with the ascending aorta and internal carotid IDIFs dropped to 7.5% and 0.05%, when using a 2-tissue-compartment model and Patlak analysis, respectively. However, microparameters (K 1, k 2, k 3) derived from the corrected internal carotid curve differed significantly from those obtained using the ascending aorta. Conclusion: These results suggest that partial-volume-corrected internal carotids may be used to estimate Ki but not kinetic microparameters. Further validation in a larger patient cohort with more variable kinetics is needed for more definitive conclusions.


Assuntos
Artéria Carótida Interna , Tomografia por Emissão de Pósitrons , Humanos , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/metabolismo , Fluordesoxiglucose F18/metabolismo , Glucose/metabolismo , Artérias Carótidas/diagnóstico por imagem
3.
Med Phys ; 51(1): 139-155, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38047554

RESUMO

BACKGROUND: The use of computed tomography (CT) for attenuation correction (AC) in whole-body PET/CT can result in a significant contribution to radiation exposure. This can become a limiting factor for reducing considerably the overall radiation exposure of the patient when using the new long axial field of view (LAFOV) PET scanners. However, recent CT technology have introduced features such as the tin (Sn) filter, which can substantially reduce the CT radiation dose. PURPOSE: The purpose of this study was to investigate the ultra-low dose CT for attenuation correction using the Sn filter together with other dose reduction options such as tube current (mAs) reduction. We explore the impact of dose reduction in the context of AC-CT and how it affects PET image quality. METHODS: The study evaluated a range of ultra-low dose CT protocols using five physical phantoms that represented a broad collection of tissue electron densities. A long axial field of view (LAFOV) PET/CT scanner was used to scan all phantoms, applying various CT dose reduction parameters such as reducing tube current (mAs), increasing the pitch value, and applying the Sn filter. The effective dose resulting from the CT scans was determined using the CTDIVol reported by the scanner. Several voxel-based and volumes of interest (VOI)-based comparisons were performed to compare the ultra-low dose CT images, the generated attenuation maps, and corresponding PET images against those images acquired with the standard low dose CT protocol. Finally, two patient datasets were acquired using one of the suggested ultra-low dose CT settings. RESULTS: By incorporating the Sn filter and adjusting mAs to the lowest available value, the radiation dose in CT images of PBU-60 phantom was significantly reduced; resulting in an effective dose of nearly 2% compared to the routine low dose CT protocols currently in clinical use. The assessment of PET images using VOI and voxel-based comparisons indicated relative differences (RD%) of under 6% for mean activity concentration (AC) in the torso phantom and patient dataset and under 8% for a source point in the CIRS phantom. The maximum RD% value of AC was 14% for the point source in the CIRS phantom. Increasing the tube current from 6 mAs to 30 mAs in patients with high BMI, or with arms down, can suppress the photon starvation artifact, whilst still preserving a dose reduction of 90%. CONCLUSIONS: Introducing a Sn filter in CT imaging lowers radiation dose by more than 90%. This reduction has minimal effect on PET image quantification at least for patients without Body Mass Index (BMI) higher than 30. Notably, this study results need validation using a larger clinical PET/CT dataset in the future, including patients with higher BMI.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Tomógrafos Computadorizados , Tomografia por Emissão de Pósitrons/métodos , Imagens de Fantasmas
4.
Cancers (Basel) ; 15(21)2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37958347

RESUMO

The latest technical development in the field of positron emission tomography/computed tomography (PET/CT) imaging has been the extension of the PET axial field-of-view. As a result of the increased number of detectors, the long axial field-of-view (LAFOV) PET systems are not only characterized by a larger anatomical coverage but also by a substantially improved sensitivity, compared with conventional short axial field-of-view PET systems. In clinical practice, this innovation has led to the following optimization: (1) improved overall image quality, (2) decreased duration of PET examinations, (3) decreased amount of radioactivity administered to the patient, or (4) a combination of any of the above. In this review, novel applications of LAFOV PET in oncology are highlighted and future directions are discussed.

5.
J Nucl Med ; 64(11): 1815-1820, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37536740

RESUMO

The purpose of this study was to quantify any differences between the SUVs of 89Zr immuno-PET scans obtained using a PET/CT system with a long axial field of view (LAFOV; Biograph Vision Quadra) compared to a PET/CT system with a short axial field of view (SAFOV; Biograph Vision) and to evaluate how LAFOV PET scan duration affects image noise and SUV metrics. Methods: Five metastatic breast cancer patients were scanned consecutively on SAFOV and LAFOV PET/CT scanners. Four additional patients were scanned using only LAFOV PET/CT. Scans on both systems lasted approximately 30 min and were acquired 4 d after injection of 37 MBq of 89Zr-trastuzumab. LAFOV list-mode data were reprocessed to obtain images acquired using shorter scan durations (15, 10, 7.5, 5, and 3 min). Volumes of interest were placed in healthy tissues, and tumors were segmented semiautomatically to compare coefficients of variation and to perform Bland-Altman analysis on SUV metrics (SUVmax, SUVpeak, and SUVmean). Results: Using 30-min images, 2 commonly used lesion SUV metrics were higher for SAFOV than for LAFOV PET (SUVmax, 16.2% ± 13.4%, and SUVpeak, 10.1% ± 7.2%), whereas the SUVmean of healthy tissues showed minimal differences (0.7% ± 5.8%). Coefficients of variation in the liver derived from 30-min SAFOV PET were between those of 3- and 5-min LAFOV PET. The smallest SUVmax and SUVpeak differences between SAFOV and LAFOV were found for 3-min LAFOV PET. Conclusion: LAFOV 89Zr immuno-PET showed a lower SUVmax and SUVpeak than SAFOV because of lower image noise. LAFOV PET scan duration may be reduced at the expense of increasing image noise and bias in SUV metrics. Nevertheless, SUVpeak showed only minimal bias when reducing scan duration from 30 to 10 min.


Assuntos
Neoplasias da Mama , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Feminino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Trastuzumab , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Mama/diagnóstico por imagem
6.
Clin Transl Imaging ; 11(3): 297-306, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37275950

RESUMO

Purpose: We report the findings of four critically ill patients who underwent an [18F]FDG-PET/CT because of persistent inflammation during the late phase of their COVID-19. Methods: Four mechanically ventilated patients with COVID-19 were retrospectively discussed in a research group to evaluate the added value of [18F]FDG-PET/CT. Results: Although pulmonary PET/CT findings differed, bilateral lung anomalies could explain the increased CRP and leukocytes in all patients. This underscores the limited ability of the routine laboratory to discriminate inflammation from secondary infections. Based on PET/CT findings, a secondary infection/inflammatory focus was suspected in two patients (pancreatitis and gastritis). Lymphadenopathy was present in patients with a detectable SARS-CoV-2 viral load. Muscle uptake around the hips or shoulders was observed in all patients, possibly due to the process of heterotopic ossification. Conclusion: This case series illustrates the diagnostic potential of [18F]FDG-PET/CT imaging in critically ill patients with persistent COVID-19 for the identification of other causes of inflammation and demonstrates that this technique can be performed safely in mechanically ventilated critically ill patients.

7.
Cancer Imaging ; 22(1): 69, 2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36527149

RESUMO

This review describes the main benefits of using long axial field of view (LAFOV) PET in clinical applications. As LAFOV PET is the latest development in PET instrumentation, many studies are ongoing that explore the potentials of these systems, which are characterized by ultra-high sensitivity. This review not only provides an overview of the published clinical applications using LAFOV PET so far, but also provides insight in clinical applications that are currently under investigation. Apart from the straightforward reduction in acquisition times or administered amount of radiotracer, LAFOV PET also allows for other clinical applications that to date were mostly limited to research, e.g., dual tracer imaging, whole body dynamic PET imaging, omission of CT in serial PET acquisition for repeat imaging, and studying molecular interactions between organ systems. It is expected that this generation of PET systems will significantly advance the field of nuclear medicine and molecular imaging.


Assuntos
Elétrons , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos
8.
Diagnostics (Basel) ; 12(11)2022 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-36359537

RESUMO

The clinical presentation of giant cell arteritis (GCA) is often nonspecific. Differentiating GCA from infectious, malignant, or other autoimmune pathology based on signs, symptoms, and laboratory parameters may therefore be difficult. Fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) imaging is an established tool in the diagnostic workup of GCA. An advantage of 18F-FDG-PET/CT is its ability to assist in the differential diagnosis by being able to demonstrate infection, inflammation, and malignancy when used in conjunction with clinical and laboratory data. Downsides to the use of 18F-FDG-PET/CT include its relatively low spatial resolution, associated radiation exposure, and the relatively long duration of imaging, causing limited availability and patient inconvenience. The advent of long axial field-of-view (LAFOV) PET/CT systems allows for PET imaging at a reduced imaging time or reduced tracer dose while maintaining high image quality. Here, we provide the first reported case of a patient with GCA and polymyalgia rheumatica (PMR) diagnosed using LAFOV PET/CT imaging. The patient presented in this case report had already been experiencing nonspecific symptoms for several years for which no cause was found. Lab investigations showed increased inflammatory parameters as well as persistent anemia. 18F-FDG LAFOV PET/CT attained high-quality images with clear signs of GCA and PMR even at 1 min of scan duration.

9.
EJNMMI Phys ; 9(1): 74, 2022 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-36308568

RESUMO

BACKGROUND: Excellent performance characteristics of the Vision Quadra PET/CT, e.g. a substantial increase in sensitivity, allow for precise measurements of image-derived input functions (IDIF) and tissue time activity curves. Previously we have proposed a method for a reduced 30 min (as opposed to 60 min) whole body 18F-FDG Patlak PET imaging procedure using a previously published population-averaged input function (PIF) scaled to IDIF values at 30-60 min post-injection (p.i.). The aim of the present study was to apply this method using the Vision Quadra PET/CT, including the use of a PIF to allow for shortened scan durations. METHODS: Twelve patients with suspected lung malignancy were included and received a weight-based injection of 18F-FDG. Patients underwent a 65-min dynamic PET acquisition which were reconstructed using European Association of Nuclear Medicine Research Ltd. (EARL) standards 2 reconstruction settings. A volume of interest (VOI) was placed in the ascending aorta (AA) to obtain the IDIF. An external PIF was scaled to IDIF values at 30-60, 40-60, and 50-60 min p.i., respectively, and parametric 18F-FDG influx rate constant (Ki) images were generated using a t* of 30, 40 or 50 min, respectively. Herein, tumour lesions as well as healthy tissues, i.e. liver, muscle tissue, spleen and grey matter, were segmented. RESULTS: Good agreement between the IDIF and corresponding PIF scaled to 30-60 min p.i. and 40-60 min p.i. was obtained with 7.38% deviation in Ki. Bland-Altman plots showed excellent agreement in Ki obtained using the PIF scaled to the IDIF at 30-60 min p.i. and at 40-60 min p.i. as all data points were within the limits of agreement (LOA) (- 0.004-0.002, bias: - 0.001); for the 50-60 min p.i. Ki, all except one data point fell in between the LOA (- 0.021-0.012, bias: - 0.005). CONCLUSIONS: Parametric whole body 18F-FDG Patlak Ki images can be generated non-invasively on a Vision Quadra PET/CT system. In addition, using a scaled PIF allows for a substantial (factor 2 to 3) reduction in scan time without substantial loss of accuracy (7.38% bias) and precision (image quality and noise interference).

10.
Eur J Nucl Med Mol Imaging ; 49(13): 4652-4660, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35876867

RESUMO

PURPOSE: Current European Association of Nuclear Medicine (EANM) Research Ltd. (EARL) guidelines for the standardisation of PET imaging developed for conventional systems have not yet been adjusted for long axial field-of-view (LAFOV) systems. In order to use the LAFOV Siemens Biograph Vision Quadra PET/CT (Siemens Healthineers, Knoxville, TN, USA) in multicentre research and harmonised clinical use, compliance to EARL specifications for 18F-FDG tumour imaging was explored in the current study. Additional tests at various locations throughout the LAFOV and the use of shorter scan durations were included. Furthermore, clinical data were collected to further explore and validate the effects of reducing scan duration on semi-quantitative PET image biomarker accuracy and precision when using EARL-compliant reconstruction settings. METHODS: EARL compliance phantom measurements were performed using the NEMA image quality phantom both in the centre and at various locations throughout the LAFOV. PET data (maximum ring difference (MRD) = 85) were reconstructed using various reconstruction parameters and reprocessed to obtain images at shorter scan durations. Maximum, mean and peak activity concentration recovery coefficients (RC) were obtained for each sphere and compared to EARL standards specifications. Additionally, PET data (MRD = 85) of 10 oncological patients were acquired and reconstructed using various reconstruction settings and reprocessed from 10 min listmode acquisition into shorter scan durations. Per dataset, SUVs were derived from tumour lesions and healthy tissues. ANOVA repeated measures were performed to explore differences in lesion SUVmax and SUVpeak. Wilcoxon signed-rank tests were performed to evaluate differences in background SUVpeak and SUVmean between scan durations. The coefficient of variation (COV) was calculated to characterise noise. RESULTS: Phantom measurements showed EARL compliance for all positions throughout the LAFOV for all scan durations. Regarding patient data, EARL-compliant images showed no clinically meaningful significant differences in lesion SUVmax and SUVpeak or background SUVmean and SUVpeak between scan durations. Here, COV only varied slightly. CONCLUSION: Images obtained using the Vision Quadra PET/CT comply with EARL specifications. Scan duration and/or activity administration can be reduced up to a factor tenfold without the interference of increased noise.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Imagens de Fantasmas , Biomarcadores
12.
Clin Nucl Med ; 44(8): 612-619, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31274606

RESUMO

PURPOSE: Neuroendocrine tumors (NETs) can produce neuroendocrine amines resulting in symptoms. Selecting the most active amine-producing tumor lesions for local treatment might be beneficial for patients with metastatic small intestinal NET. Tumor burden correlates with catecholamine pathway activity. We analyzed interlesional heterogeneity with F-DOPA PET scans in patients with small intestinal NET and investigated if lesions with substantially higher F-DOPA uptake could be identified. METHODS: In this retrospective, observational study, the F-DOPA uptake was calculated by dividing SUVpeak of the lesion by the SUVmean of the background organ. The magnitude of heterogeneity between lesions within a patient was calculated by dividing the lesion with the highest by the one with the lowest F-DOPA uptake. Lesions with a higher F-DOPA uptake than the upper inner or outer fence (>1.5 or 3 times the interquartile range above the third quartile) were defined as lesions with mild or extreme high F-DOPA uptake, respectively, and presence of these was determined in patients with 10 lesions or more. RESULTS: F-DOPA was detected over 680 lesions in 38 patients, of which 35 were serotonin producing. F-DOPA uptake varied with a median of 8-fold up to 44-fold between lesions within a patient. In 12 of 20 evaluable patients, lesions with mild high F-DOPA uptake were found, and in 5, lesions with extreme high F-DOPA uptake. CONCLUSIONS: F-DOPA-PET showed considerable heterogeneity in F-DOPA uptake between tumor lesions and identified lesions within patients with mild or extreme high F-DOPA uptake.


Assuntos
Di-Hidroxifenilalanina , Radioisótopos de Flúor , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS