Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Endosc Int Open ; 12(3): E428-E434, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38504741

RESUMO

Background and study aims Reprocessing reusable endoscopes is challenging due to their non-sterilizable nature. Disinfection has been shown to have a significant risk of failure with serious consequences. Single-use endoscopes can eliminate contamination risk and reduce workflow delays caused by reprocessing. This study evaluated the clinical performance of single-use gastroscopes in patients undergoing esophagogastroduodenoscopy (EGD). Patients and methods In this case series, 60 patients underwent EGD using single-use gastroscopes, with 34 procedures in the endoscopy department and 26 in the intensive care unit. The primary outcome was successful completion of the intended EGD objective. Furthermore, certified endoscopists assessed device performance on a five-point Likert scale (ranging from 1-"much worse" to 5-"much better"), considering their experience with a reusable gastroscope. Results Successful completion of EGDs using only the single-use gastroscope was achieved in 58 of 60 cases (96.7%). In two cases, crossover to an ultra-slim endoscope was necessary to either reach the esophageal stenosis or to transverse the stenosis. Overall satisfaction was rated as comparable to reusable scopes in 51 of 56 cases (91.1%) and inferior in five cases (8.9%). The lower weight of the single-use gastroscope was rated as superior in 42 of 60 cases (70.0%). Drawbacks included reduced image quality (23 of 45 cases; 51.1%). Feedback included the absence of a freeze button, lens cleaning issues, and small image size. Conclusions Single-use gastroscopes exhibited a high EGD completion rate and effectiveness for various indications. Further research should focus on evaluating the implementation of single-use gastroscopes in a comprehensive context, considering clinical effectiveness, costs, and environmental impact.

2.
Gut ; 73(4): 613-621, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38182137

RESUMO

OBJECTIVE: Contaminated duodenoscopes caused several hospital outbreaks. Despite efforts to reduce contamination rates, 15% of patient-ready duodenoscopes are still contaminated with gastrointestinal microorganisms. This study aimed to provide an overview of duodenoscope contamination over time, identify risk factors and study the effects of implemented interventions. DESIGN: Duodenoscope culture sets between March 2015 and June 2022 at a Dutch tertiary care centre were analysed. Contamination was defined as (1) the presence of microorganisms of oral or gastrointestinal origin (MGO) or (2) any other microorganism with ≥20 colony-forming units/20 mL (AM20). A logistic mixed effects model was used to identify risk factors and assess the effect of interventions, such as using duodenoscopes with disposable caps, replacing automated endoscope reprocessors (AER) and conducting audits in the endoscopy department. RESULTS: A total of 404 culture sets were analysed. The yearly contamination rate with MGO showed great variation, ranging from 14.3% to 47.5%. Contamination with AM20 increased up to 94.7% by 2022. For both MGO and AM20, the biopsy and suction channels were the most frequently contaminated duodenoscope components. The studied interventions, including audits, AER replacement and implementation of duodenoscopes with disposable caps, did not show a clear association with contamination rates. CONCLUSION: Duodenoscope contamination remains a significant problem, with high contamination rates despite several interventions. Reprocessing the biopsy and suction channels is especially challenging. Changes in the design of reusable duodenoscopes, such as enabling sterilisation or easily replaceable channels, are necessary to facilitate effective duodenoscope reprocessing and to eliminate the risk of duodenoscope-associated infections.


Assuntos
Infecção Hospitalar , Duodenoscópios , Humanos , Colangiopancreatografia Retrógrada Endoscópica , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/epidemiologia , Óxido de Magnésio , Estudos Retrospectivos , Centros de Atenção Terciária
3.
Endoscopy ; 56(3): 198-204, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37848074

RESUMO

BACKGROUND: Current duodenoscope reprocessing protocols are insufficient to prevent contamination and require adaptations to prevent endoscopy-associated infections (EAIs). This study aimed to investigate the effect of a new endoscope cleaning brush on the contamination rate of ready-to-use duodenoscopes. METHODS: This retrospective before-and-after intervention study collected duodenoscope surveillance culture results from March 2018 to June 2022. Contamination was defined as ≥1 colony-forming unit of a microorganism of gut or oral origin (MGO). In December 2020, an endoscope cleaning brush with a sweeper design was introduced as an intervention in the manual cleaning of duodenoscopes. A logistic mixed-effects model was used to study the effects of this intervention. RESULTS: Data were collected from 176 culture sets before the new brush's introduction and 81 culture sets afterwards. Pre-introduction, culture sets positive with an MGO comprised 45.5% (95%CI 38.3%-52.8%; 80/176), decreasing to 17.3% (95%CI 10.6%-26.9%; 14/81) after implementation of the new brush. Compared with the former brush, duodenoscopes cleaned with the new brush had lower odds of contamination with MGOs (adjusted odds ratio 0.25, 95%CI 0.11-0.58; P=0.001) CONCLUSIONS: Use of the new brush in manual cleaning reduced contamination with MGOs and is expected to prevent EAIs. These findings should be confirmed in future prospective randomized studies.


Assuntos
Duodenoscópios , Óxido de Magnésio , Humanos , Estudos Retrospectivos , Desinfecção/métodos , Contaminação de Equipamentos/prevenção & controle , Endoscopia Gastrointestinal
6.
Scand J Gastroenterol ; 58(8): 900-907, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36762705

RESUMO

BACKGROUND AND AIMS: The clinical course of patients with liver cirrhosis and adherence to hepatocellular carcinoma (HCC) screening guidelines are not well studied in the Netherlands. We investigated this and potential risk factors for decompensation and transplant-free survival (TFS) in a large regional cohort. METHODS: We performed a retrospective cohort study of patients with confirmed liver cirrhosis in Amsterdam, the Netherlands. Clinical parameters, decompensation events, development of HCC, and medication use were extracted from medical records. RESULTS: In total, 681 hospitalized and outpatients were included. Mortality risk was increased by: age (aHR 1.07, p < 0.01), smoking (aHR 1.83, p < 0.01), decompensated initial presentation (aHR 1.43, p = 0.04) and increased MELD (aHR 1.07, p < 0.01). PPI use tended to increase mortality risk (aHR 1.35, p = 0.05). The risk of future decompensation was increased with increased age (aHR 1.02, p < 0.01), decompensated initial presentation (aHR 1.37, p = 0.03) and alcohol misuse as etiology (aHR 1.34, p = 0.04). Adequately screened patients for HCC had a longer TFS compared to patients who were not (48 vs 22 months), p < 0.01). CONCLUSIONS: In patients with cirrhosis, decompensation at initial presentation was associated with an increased risk of future decompensation and mortality. Alcoholic cirrhosis was associated with an increased risk of future decompensation. Adequate HCC surveillance was associated with markedly better survival.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Estudos Retrospectivos , Cirrose Hepática/patologia , Cirrose Hepática Alcoólica/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA