Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Neth Heart J ; 32(3): 130-139, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38214880

RESUMO

AIM: To evaluate changes in healthcare utilisation and comprehensive packages of care activities and procedures (referred in the Netherlands to as 'diagnose-behandelcombinatie (DBC) care products) during the implementation of the TeleCheck-AF approach (teleconsultation supported by app-based heart rate/rhythm monitoring) in a Dutch atrial fibrillation (AF) clinic. METHODS AND RESULTS: In the Maastricht University Medical Centre+ AF Clinic, data on healthcare utilisation and DBC care products for patients consulted by both a conventional approach in 2019 and the TeleCheck-AF approach in 2020 were analysed. A patient experience survey was performed. Thirty-seven patients (median age 68 years; 40% women) were analysed. With the conventional approach, 35 face-to-face consultations and 0 teleconsultations were conducted. After the implementation of TeleCheck-AF, the number of face-to-face consultations dropped by 80% (p < 0.001) and teleconsultations increased to 45 (p < 0.001). While 42 electrocardiograms (ECGs) and 25 Holter ECGs or echocardiograms were recorded when using the conventional approach, the number of ECGs decreased by 71% (p < 0.001) and Holter ECGs or echocardiograms by 72% (p < 0.001) with the TeleCheck-AF approach. The emergency department patient presentations showed no statistically significant change (p = 0.33). Overall, 57% of medium-weight DBC care products were changed to light-weight ones during implementation of the TeleCheck-AF approach. Patient satisfaction with the TeleCheck-AF approach was high. CONCLUSION: The implementation of TeleCheck-AF led to a change in healthcare utilisation, a change from medium-weight to light-weight DBC care products and a reduction in patient burden. These results created the basis for a new reimbursement code for the TeleCheck-AF approach in the Netherlands.

2.
Heart ; 110(9): 626-634, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38182278

RESUMO

OBJECTIVE: To evaluate adherence and adherence consistency to the handheld ECG device-based screening protocol and their association with adverse cerebral and cardiovascular outcomes in two systematic atrial fibrillation (AF) screening programmes. METHODS: In 2012 (Systematic ECG Screening for Atrial Fibrillation Among 75-Year Old Subjects in the Region of Stockholm and Halland, Sweden (STROKESTOP) study) and 2016 (Stepwise mass screening for atrial fibrillation using N-terminal pro b-type natriuretic peptide (STROKESTOP II) study), half of all 75- and 76-year-old inhabitants of up to two Swedish regions were invited to participate in a systematic AF screening programme. Participants were instructed to perform 30-second measurements twice daily in STROKESTOP and four times daily in STROKESTOP II for 2 weeks. Adherence was defined as the number of measurements performed divided by the number of measurements asked, whereas adherence consistency was defined as the number of days with complete registrations. RESULTS: In total, 6436 participants (55.7% female) from STROKESTOP and 3712 (59.8% female) from STROKESTOP II were included. Median adherence and adherence consistency were 100 (92-100)% and 12 (11-13) days in STROKESTOP and 90 (75-98)% and 8 (3-11) days in STROKESTOP II. Female sex and lower education were factors associated with both optimal adherence and adherence consistency in both studies. In STROKESTOP, low adherence and adherence consistency were associated with higher risk of adverse cerebral and cardiovascular outcomes (HR for composite primary endpoint 1.30 (1.11 to 1.51), p=0.001), including stroke (HR 1.68 (1.22 to 2.32), p=0.001) and dementia (1.67 (1.27 to 2.19), p<0.001). CONCLUSIONS: Adherence to twice daily handheld ECG measurements in STROKESTOP was higher than to four times daily measurements in STROKESTOP II. Female sex and lower educational attainment were associated with ≥100% adherence and adherence consistency. Low adherence and adherence consistency were associated with a higher risk of adverse outcomes.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Feminino , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Suécia/epidemiologia , Programas de Rastreamento/métodos , Escolaridade , Eletrocardiografia
3.
Clin Cardiol ; 47(1): e24161, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37872853

RESUMO

BACKGROUND: In the Rate Control versus Electrical Cardioversion Trial 7-Acute Cardioversion versus Wait and See, patients with recent-onset atrial fibrillation (AF) were randomized to either early or delayed cardioversion. AIM: This prespecified sub-analysis aimed to evaluate heart rate during AF recurrences after an emergency department (ED) visit identified by an electrocardiogram (ECG)-based handheld device. METHODS: After the ED visit, included patients (n = 437) were asked to use an ECG-based handheld device to monitor for recurrences during the 4-week follow-up period. 335 patients used the handheld device and were included in this analysis. Recordings from the device were collected and assessed for heart rhythm and rate. Optimal rate control was defined as a target resting heart rate of <110 beats per minute (bpm). RESULTS: In 99 patients (29.6%, mean age 67 ± 10 years, 39.4% female, median 6 [3-12] AF recordings) a total of 314 AF recurrences (median 2 [1-3] per patient) were identified during follow-up. The average median resting heart rate at recurrence was 100 ± 21 bpm in the delayed vs 112 ± 25 bpm in the early cardioversion group (p = .011). Optimal rate control was seen in 68.4% [21.3%-100%] and 33.3% [0%-77.5%] of recordings (p = .01), respectively. Randomization group [coefficient -12.09 (-20.55 to -3.63, p = .006) for delayed vs. early cardioversion] and heart rate on index ECG [coefficient 0.46 (0.29-0.63, p < .001) per bpm increase] were identified on multivariable analysis as factors associated with lower median heart rate during AF recurrences. CONCLUSION: A delayed cardioversion strategy translated into a favorable heart rate profile during AF recurrences.


Assuntos
Fibrilação Atrial , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Eletrocardiografia , Frequência Cardíaca , Recidiva , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
Int J Cardiol Heart Vasc ; 49: 101305, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38053981

RESUMO

Background: In atrial fibrillation (AF) patients, presence of expiratory airflow limitation may negatively impact treatment outcomes. AF patients are not routinely screened for expiratory airflow limitation, but existing examinations can help identify at-risk individuals. We aimed to assess the diagnostic value of repurposing existing assessments from the pre-ablation work-up to identify and understand the characteristics of affected patients. Methods: We screened 110 consecutive AF patients scheduled for catheter ablation with handheld spirometry. Routine pre-ablation work-up included cardiac computed tomographic angiography (CCTA), transthoracic echocardiography and polygraphy. CCTA was analyzed qualitatively for emphysema and airway abnormalities. Multivariate logistic regression analysis was performed to determine predictors of expiratory airflow limitation. Results: We found that 25 % of patients had expiratory airflow limitation, which was undiagnosed in 86 % of these patients. These patients were more likely to have pulmonary abnormalities on CCTA, including emphysema (odds ratio [OR] 4.2, 95 % confidence interval [CI] 1.12-15.1, p < 0.05) and bronchial wall thickening (OR 2.6, 95 % CI 1.0-6.5, p < 0.05). The absence of pulmonary abnormalities on CCTA accurately distinguished patients with normal lung function from those with airflow limitation (negative predictive value: 85 %). Echocardiography and polygraphy did not contribute significantly to identifying airflow limitation. Conclusions: In conclusion, routine pre-ablation CCTA can detect pulmonary abnormalities in AF patients with airflow limitation, guiding further pulmonary assessment. Future studies should investigate its impact on ablation procedure success.

5.
Europace ; 25(7)2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37421318

RESUMO

AIMS: Chronic obstructive pulmonary disease (COPD) negatively impacts the efficacy of heart rhythm control treatments in patients with atrial fibrillation (AF). Although COPD is recognized as a risk factor for AF, practical guidance about how and when to screen for COPD is not available. Herein, we describe the implementation of an integrated screening and management pathway for COPD into the existing pre-ablation work-up in an AF outpatient clinic infrastructure. METHODS AND RESULTS: Consecutive unselected patients accepted for AF catheter ablation in the Maastricht University Medical Center+ were prospectively screened for airflow limitation using handheld (micro)spirometry at the pre-ablation outpatient clinic supervised by an AF nurse. Patients with results suggestive of airflow limitation were offered referral to the pulmonologist. Handheld (micro)spirometry was performed in 232 AF patients, which provided interpretable results in 206 (88.8%) patients. Airflow limitation was observed in 47 patients (20.3%). Out of these 47 patients, 29 (62%) opted for referral to the pulmonologist. The primary reason for non-referral was low perceived symptom burden. Using this screening strategy 17 (out of 232; 7.3%) ultimately received a diagnosis of chronic respiratory disease, either COPD or asthma. CONCLUSION: A COPD care pathway can successfully be embedded in an existing AF outpatient clinic infrastructure, using (micro)spirometry and remote analysis of results. Although one out of five patients had results suggestive of an underlying chronic respiratory disease, only 62% of these patients opted for a referral. Pre-selection of patients as well as patient education might increase the diagnostic yield and requires further research.


Assuntos
Fibrilação Atrial , Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/terapia , Pulmão , Fatores de Risco
6.
Clin Res Cardiol ; 112(6): 834-845, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36773038

RESUMO

BACKGROUND: Sleep-disordered breathing (SDB) is prevalent in up to 50% of patients referred for atrial fibrillation (AF) catheter ablation (CA). Currently, it remains unclear how to improve pre-selection for SDB screening in patients with AF. AIM: We aimed to (1) assess the accuracy of the STOP-Bang screening questionnaire for detection of SDB within an AF population referred for CA; (2) derive a refined, AF-specific SDB score to improve pre-selection. METHODS: Consecutive AF patients referred for CA without a history of SDB and/or SDB screening were included. Patients were digitally referred to the previously implemented Virtual-SAFARI SDB screening and management pathway including a home sleep test. An apnoea-hypopnoea index (AHI) of  ≥ 15 was interpreted as moderate-to-severe SDB. Logistic regression analysis was used to assess characteristics associated with moderate-to-severe SDB to refine pre-selection for SDB screening. RESULTS: Of 206 included patients, 51% were diagnosed with moderate-to-severe SDB. The STOP-Bang questionnaire performed poorly in detecting SDB, with an area under the receiver operating characteristic curve (AUROC) of 0.647 (95% Confidence-Interval (CI) 0.573-0.721). AF-specific refinement resulted in the BOSS-GAP score. Therein, BMI with cut-off point ≥ 27 kg/m2 and previous stroke or transient ischaemic attack (TIA) were added, while tiredness and neck circumference were removed. The BOSS-GAP score performed better with an AUROC of 0.738 (95% CI 0.672-0.805) in the overall population. CONCLUSION: AF-specific refinement of the STOP-Bang questionnaire moderately improved detection of SDB in AF patients referred for CA. Whether questionnaires bring benefits for pre-selection of SDB compared to structural screening in patients with AF requires further studies. TRIAL REGISTRATION NUMBER: ISOLATION was registered NCT04342312, 13-04-2020.


Assuntos
Fibrilação Atrial , Síndromes da Apneia do Sono , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/epidemiologia , Inquéritos e Questionários , Polissonografia/métodos , Curva ROC
8.
Europace ; 25(3): 835-844, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36748247

RESUMO

AIMS: Although mobile health tools using photoplethysmography (PPG) technology have been validated for the detection of atrial fibrillation (AF), their utility for heart rate assessment during AF remains unclear. Therefore, we aimed to evaluate the accuracy of continuous PPG-based 1 min mean heart rate assessment during AF. METHODS AND RESULTS: Persistent AF patients were provided with Holter electrocardiography (ECG) (for ≥24 h) simultaneously with a PPG-equipped smartwatch. Both the PPG-based smartwatch and Holter ECG automatically and continuously monitored patients' heart rate/rhythm. ECG and PPG recordings were synchronized and divided into 1 min segments, from which a PPG-based and an ECG-based average heart rate estimation were extracted. In total, 47 661 simultaneous ECG and PPG 1 min heart rate segments were analysed in 50 patients (34% women, age 73 ± 8 years). The agreement between ECG-determined and PPG-determined 1 min mean heart rate was high [root mean squared error (RMSE): 4.7 bpm]. The 1 min mean heart rate estimated using PPG was accurate within ±10% in 93.7% of the corresponding ECG-derived 1 min mean heart rate segments. PPG-based 1 min mean heart rate estimation was more often accurate during night-time (97%) than day-time (91%, P < 0.001) and during low levels (96%) compared to high levels of motion (92%, P < 0.001). A neural network with a 10 min history of the recording did not further improve the PPG-based 1 min mean heart rate assessment [RMSE: 4.4 (95% confidence interval: 3.5-5.2 bpm)]. Only chronic heart failure was associated with a lower agreement between ECG-derived and PPG-derived 1 min mean heart rates (P = 0.040). CONCLUSION: During persistent AF, continuous PPG-based 1 min mean heart rate assessment is feasible in 60% of the analysed period and shows high accuracy compared with Holter ECG for heart rates <110 bpm.


Assuntos
Fibrilação Atrial , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Fibrilação Atrial/diagnóstico , Frequência Cardíaca , Fotopletismografia/métodos , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial , Algoritmos
9.
Eur J Cardiovasc Nurs ; 22(4): 412-424, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-35932189

RESUMO

AIMS: The aim of this TeleCheck-AF sub-analysis was to evaluate motivation and adherence to on-demand heart rate/rhythm monitoring app in patients with atrial fibrillation (AF). METHODS AND RESULTS: Patients were instructed to perform 60 s app-based heart rate/rhythm recordings 3 times daily and in case of symptoms for 7 consecutive days prior to teleconsultation. Motivation was defined as number of days in which the expected number of measurements (≥3/day) were performed per number of days over the entire prescription period. Adherence was defined as number of performed measurements per number of expected measurements over the entire prescription period.Data from 990 consecutive patients with diagnosed AF [median age 64 (57-71) years, 39% female] from 10 centres were analyzed. Patients with both optimal motivation (100%) and adherence (≥100%) constituted 28% of the study population and had a lower percentage of recordings in sinus rhythm [90 (53-100%) vs. 100 (64-100%), P < 0.001] compared with others. Older age and absence of diabetes were predictors of both optimal motivation and adherence [odds ratio (OR) 1.02, 95% coincidence interval (95% CI): 1.01-1.04, P < 0.001 and OR: 0.49, 95% CI: 0.28-0.86, P = 0.013, respectively]. Patients with 100% motivation also had ≥100% adherence. Independent predictors for optimal adherence alone were older age (OR: 1.02, 95% CI: 1.00-1.04, P = 0.014), female sex (OR: 1.70, 95% CI: 1.29-2.23, P < 0.001), previous AF ablation (OR: 1.35, 95% CI: 1.03-1.07, P = 0.028). CONCLUSION: In the TeleCheck-AF project, more than one-fourth of patients had optimal motivation and adherence to app-based heart rate/rhythm monitoring. Older age and absence of diabetes were predictors of optimal motivation/adherence.


Assuntos
Fibrilação Atrial , Diabetes Mellitus , Aplicativos Móveis , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Frequência Cardíaca , Motivação
10.
Heart ; 109(1): 26-33, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-36322782

RESUMO

OBJECTIVE: The Rate Control versus Electrical Cardioversion Trial 7-Acute Cardioversion versus Wait and See trial compared early to delayed cardioversion for patients with recent-onset symptomatic atrial fibrillation (AF). This study aims to evaluate the adherence to a 4-week mobile health (mHealth) prescription to detect AF recurrences after an emergency department visit. METHODS: After the emergency department visit, the 437 included patients, irrespective of randomisation arm (early or delayed cardioversion), were asked to record heart rate and rhythm for 1 min three times daily and in case of symptoms by an electrocardiography-based handheld device for 4 weeks (if available). Adherence was appraised as number of performed measurements per number of recordings asked from the patient and was evaluated for longitudinal adherence consistency. All patients who used the handheld device were included in this subanalysis. RESULTS: 335 patients (58% males; median age 67 (IQR 11) years) were included. The median overall adherence of all patients was 83.3% (IQR 29.9%). The median number of monitoring days was 27 out of 27 (IQR 5), whereas the median number of full monitoring days was 16 out of 27 (IQR 14). Higher age and a previous paroxysm of AF were identified as multivariable adjusted factors associated with adherence. CONCLUSIONS: In this randomised trial, a 4-week mHealth prescription to monitor for AF recurrences after an emergency department visit for recent-onset AF was feasible with 85.7% of patients consistently using the device with at least one measurement per day. Older patients were more adherent. TRIAL REGISTRATION NUMBER: NCT02248753.


Assuntos
Fibrilação Atrial , Telemedicina , Masculino , Humanos , Idoso , Feminino , Fibrilação Atrial/terapia , Fibrilação Atrial/tratamento farmacológico , Antiarrítmicos/uso terapêutico , Frequência Cardíaca , Cardioversão Elétrica , Recidiva
11.
Int J Cardiol ; 367: 29-37, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-35963443

RESUMO

BACKGROUND: The assessment of symptom-rhythm correlation (SRC) in patients with persistent atrial fibrillation (AF) is challenging. Therefore, we performed a novel mobile app-based approach to assess SRC in persistent AF. METHODS: Consecutive persistent AF patients planned for electrical cardioversion (ECV) used a mobile app to record a 60-s photoplethysmogram (PPG) and report symptoms once daily and in case of symptoms for four weeks prior and three weeks after ECV. Within each patient, SRC was quantified by the SRC-index defined as the sum of symptomatic AF recordings and asymptomatic non-AF recordings divided by the sum of all recordings. RESULTS: Of 88 patients (33% women, age 68 ± 9 years) included, 78% reported any symptoms during recordings. The overall SRC-index was 0.61 (0.44-0.79). The study population was divided into SRC-index tertiles: low (<0.47), medium (0.47-0.73) and high (≥0.73). Patients within the low (vs high) SRC-index tertile had more often heart failure and diabetes mellitus (both 24.1% vs 6.9%). Extrasystoles occurred in 19% of all symptomatic non-AF PPG recordings. Within each patient, PPG recordings with the highest (vs lowest) tertile of pulse rates conferred an increased risk for symptomatic AF recordings (odds ratio [OR] 1.26, 95% coincidence interval [CI] 1.04-1.52) and symptomatic non-AF recordings (OR 2.93, 95% CI 2.16-3.97). Pulse variability was not associated with reported symptoms. CONCLUSIONS: In patients with persistent AF, SRC is relatively low. Pulse rate is the main determinant of reported symptoms. Further studies are required to verify whether integrating mobile app-based SRC assessment in current workflows can improve AF management.


Assuntos
Fibrilação Atrial , Aplicativos Móveis , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Cardioversão Elétrica , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
12.
Int J Cardiol Heart Vasc ; 42: 101086, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35873859

RESUMO

Atrial fibrillation (AF) is the most common sustained heart rhythm disorder and is often associated with symptoms that can significantly impact quality of life and daily functioning. Palpitations are the cardinal symptom of AF and many AF therapies are targeted towards relieving this symptom. However, up to two-third of patients also complain of dyspnea as a predominant self-reported symptom. In clinical practice it is often challenging to ascertain whether dyspnea represents an AF-related symptom or a symptom of concomitant cardiovascular and non-cardiovascular comorbidities, since common AF comorbidities such as heart failure and chronic obstructive pulmonary disease share similar symptoms. In addition, therapeutic approaches specifically targeting dyspnea have not been well validated. Thus, assessing and treating dyspnea can be difficult. This review describes the latest knowledge on the burden and pathophysiology of dyspnea in AF patients. We discuss the role of heart rhythm control interventions as well as the management of AF risk factors and comorbidities with the goal to achieve maximal relief of dyspnea. Given the different and often complex mechanistic pathways leading to dyspnea, dyspneic AF patients will likely profit from an integrated multidisciplinary approach to tackle all factors and mechanisms involved. Therefore, we propose an interdisciplinary and integrated care pathway for the work-up of dyspnea in AF patients.

14.
Clin Res Cardiol ; 111(5): 479-491, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34549333

RESUMO

AIM: We aimed to systematically review the available literature on mobile Health (mHealth) solutions, including handheld and wearable devices, implantable loop recorders (ILRs), as well as mobile platforms and support systems in atrial fibrillation (AF) detection and management. METHODS: This systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. The electronic databases PubMed (NCBI), Embase (Ovid), and Cochrane were searched for articles published until 10 February 2021, inclusive. Given that the included studies varied widely in their design, interventions, comparators, and outcomes, no synthesis was undertaken, and we undertook a narrative review. RESULTS: We found 208 studies, which were deemed potentially relevant. Of these studies included, 82, 46, and 49 studies aimed at validating handheld devices, wearables, and ILRs for AF detection and/or management, respectively, while 34 studies assessed mobile platforms/support systems. The diagnostic accuracy of mHealth solutions differs with respect to the type (handheld devices vs wearables vs ILRs) and technology used (electrocardiography vs photoplethysmography), as well as application setting (intermittent vs continuous, spot vs longitudinal assessment), and study population. CONCLUSION: While the use of mHealth solutions in the detection and management of AF is becoming increasingly popular, its clinical implications merit further investigation and several barriers to widespread mHealth adaption in healthcare systems need to be overcome. Mobile health solutions for atrial fibrillation detection and management: a systematic review.


Assuntos
Fibrilação Atrial , Telemedicina , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Eletrocardiografia , Humanos
15.
Europace ; 24(4): 565-575, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34718525

RESUMO

AIMS: In atrial fibrillation (AF) patients, untreated sleep-disordered breathing (SDB) is associated with lower success rates of rhythm control strategies and as such structured SDB testing is recommended. Herein, we describe the implementation of a virtual SDB management pathway in an AF outpatient clinic and examine the utility and feasibility of this new approach. METHODS AND RESULTS: Prospectively, consecutive AF patients accepted for AF catheter ablation procedures without previous diagnosis of SDB were digitally referred to a virtual SDB management pathway and instructed to use WatchPAT-ONE (ITAMAR) for one night. Results were automatically transferred to a virtual sleep laboratory, upon which a teleconsultation with a sleep physician was planned. Patient experience was measured using surveys. SDB testing was performed in 119 consecutive patients scheduled for AF catheter ablation procedures. The median time from digital referral to finalization of the sleep study report was 18 [11-24] days. In total, 65 patients (55%) were diagnosed with moderate-to-severe SDB. Patients with SDB were prescribed more cardiovascular drugs and had higher body mass indices (BMI, 29 ± 3.3 vs. 27 ± 4.4kg/m2, P < 0.01). Patients agreed that WatchPAT-ONE was easy to use (91%) and recommended future use of this virtual pathway in AF outpatient clinics (86%). Based on this remote SDB testing, SDB treatment was recommended in the majority of patients. CONCLUSION: This novel virtual AF management pathway allowed remote SDB testing in AF outpatient clinics with a short time to diagnosis and high patient satisfaction. Structured SDB testing results in a high detection of previously unknown SDB in AF patients scheduled for AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Síndromes da Apneia do Sono , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Humanos , Polissonografia , Sono , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/terapia
16.
Europace ; 23(7): 1003-1015, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33822029

RESUMO

AIMS: TeleCheck-AF is a multicentre international project initiated to maintain care delivery for patients with atrial fibrillation (AF) during COVID-19 through teleconsultations supported by an on-demand photoplethysmography-based heart rate and rhythm monitoring app (FibriCheck®). We describe the characteristics, inclusion rates, and experiences from participating centres according the TeleCheck-AF infrastructure as well as characteristics and experiences from recruited patients. METHODS AND RESULTS: Three surveys exploring centre characteristics (n = 25), centre experiences (n = 23), and patient experiences (n = 826) were completed. Self-reported patient characteristics were obtained from the app. Most centres were academic (64%) and specialized public cardiology/district hospitals (36%). Majority of the centres had AF outpatient clinics (64%) and only 36% had AF ablation clinics. The time required to start patient inclusion and total number of included patients in the project was comparable for centres experienced (56%) or inexperienced in mHealth use. Within 28 weeks, 1930 AF patients were recruited, mainly for remote AF control (31% of patients) and AF ablation follow-up (42%). Average inclusion rate was highest during the lockdown restrictions and reached a steady state at a lower level after easing the restrictions (188 vs. 52 weekly recruited patients). Majority (>80%) of the centres reported no problems during the implementation of the TeleCheck-AF approach. Recruited patients [median age 64 (55-71), 62% male] agreed that the FibriCheck® app was easy to use (94%). CONCLUSION: Despite different health care settings and mobile health experiences, the TeleCheck-AF approach could be set up within an extremely short time and easily used in different European centres during COVID-19.


Assuntos
Fibrilação Atrial , COVID-19 , Aplicativos Móveis , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Controle de Doenças Transmissíveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Avaliação de Resultados da Assistência ao Paciente , SARS-CoV-2
17.
Cardiology ; 146(3): 392-396, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33735889

RESUMO

Recently, we introduced the TeleCheck-AF approach, an on-demand mobile health (mHealth) infrastructure using app-based heart rate and rhythm monitoring for 7 days, to support long-term atrial fibrillation (AF) management through teleconsultation. Herein, we extend the mHealth approach to patients with recent-onset AF at the emergency department (ED). In the proposed TeleWAS-AF approach, on-demand heart rate and rhythm monitoring are used to support a wait-and-see strategy at the ED. All stable patients who present to the ED with recent-onset symptomatic AF and who are able to use mHealth solutions for heart rate and rhythm monitoring are eligible for this approach. Patients will receive both education on AF and instructions on the use of the mHealth technology before discharge from the ED. A case coordinator will subsequently check whether patients are able to activate the mHealth solution and to perform heart rate and rhythm measurements. Forty hours after AF onset, the first assessment teleconsultation with the physician will take place, determining the need for delayed cardioversion. After maximal 7 days of remote monitoring, a second assessment teleconsultation may occur, in which the rhythm can be reassessed and further treatment strategy can be discussed with the patients. This on-demand mHealth prescription increases patient involvement in the care process and treatment decision-making by encouraging self-management, while avoiding excess data-load requiring work-intensive and expensive data management. Implementation of the TeleWAS-AF approach may facilitate the management of AF in the ED and reduce the burden on the ED system, which enhances the capacity for health care utilization.


Assuntos
Fibrilação Atrial , Telemedicina , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Serviço Hospitalar de Emergência , Frequência Cardíaca , Humanos
18.
Europace ; 23(3): 345-352, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-32887994

RESUMO

During the coronavirus 2019 (COVID-19) pandemic, outpatient visits in the atrial fibrillation (AF) clinic of the Maastricht University Medical Centre (MUMC+) were transferred into teleconsultations. The aim was to develop anon-demand app-based heart rate and rhythm monitoring infrastructure to allow appropriatmanagement of AF through teleconsultation. In line with the fundamental aspects of integrated care, including actively involving patients in the care process and providing comprehensive care by a multidisciplinary team, we implemented a mobile health (mHealth) intervention to support teleconsultations with AF patients: TeleCheck-AF. The TeleCheck-AF approach guarantees the continuity of comprehensive AF management and supports integrated care through teleconsultation during COVID-19. It incorporates three important components: (i) a structured teleconsultation ('Tele'), (ii) a CE-marked app-based on-demand heart rate and rhythm monitoring infrastructure ('Check'), and (iii) comprehensive AF management ('AF'). In this article, we describe the components and implementation of the TeleCheck-AF approach in an integrated and specialized AF-clinic through teleconsultation. The TeleCheck-AF approach is currently implemented in numerous European centres during COVID-19.


Assuntos
Fibrilação Atrial/diagnóstico , COVID-19 , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Aplicativos Móveis , Consulta Remota/instrumentação , Smartphone , Potenciais de Ação , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Prestação Integrada de Cuidados de Saúde , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
19.
Front Cardiovasc Med ; 8: 757587, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35127847

RESUMO

INTRODUCTION: The TeleCheck-AF approach is an on-demand mobile health (mHealth) infrastructure incorporating mobile app-based heart rate and rhythm monitoring through teleconsultation. We evaluated feasibility and accuracy of self-reported mHealth-based AF risk factors and CHA2DS2-VASc-score in atrial fibrillation (AF) patients managed within this approach. MATERIALS AND METHODS: Consecutive patients from eight international TeleCheck-AF centers were asked to complete an app-based 10-item questionnaire related to risk factors, associated conditions and CHA2DS2-VASc-score components. Patient's medical history was retrieved from electronic health records (EHR). RESULTS: Among 994 patients, 954 (96%) patients (38% female, median age 65 years) completed the questionnaire and were included in this analysis. The accuracy of self-reported assessment was highest for pacemaker and anticoagulation treatment and lowest for heart failure and arrhythmias. Patients who knew that AF increases the stroke risk, more often had a 100% or ≥80% correlation between EHR- and app-based results compared to those who did not know (27 vs. 14% or 84 vs. 77%, P = 0.001). Thromboembolic events were more often reported in app (vs. EHR) in all countries, whereas higher self-reported hypertension and anticoagulant treatment were observed in Germany and heart failure in the Netherlands. If the app-based questionnaire alone was used for clinical decision-making on anticoagulation initiation, 26% of patients would have been undertreated and 6.1%-overtreated. CONCLUSION: Self-reported mHealth-based assessment of AF risk factors is feasible. It shows high accuracy of pacemaker and anticoagulation treatment, nevertheless, displays limited accuracy for some of the CHA2DS2-VASc-score components. Direct health care professional assessment of risk factors remains indispensable to ensure high quality clinical-decision making.

20.
Eur Heart J Digit Health ; 2(3): 363-373, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36713592

RESUMO

Aims: Within the TeleCheck-AF project, numerous centres in Europe used on-demand photoplethysmography (PPG) technology to remotely assess heart rate and rhythm in conjunction with teleconsultations. Based on the TeleCheck-AF investigator experiences, we aimed to develop an educational structured stepwise practical guide on how to interpret PPG signals and to introduce typical clinical scenarios how on-demand PPG was used. Methods and results: During an online conference, the structured stepwise practical guide on how to interpret PPG signals was discussed and further refined during an internal review process. We provide the number of respective PPG recordings (FibriCheck®) and number of patients managed within a clinical scenario during the TeleCheck-AF project. To interpret PPG recordings, we introduce a structured stepwise practical guide and provide representative PPG recordings. In the TeleCheck-AF project, 2522 subjects collected 90 616 recordings in total. The majority of these recordings were classified by the PPG algorithm as sinus rhythm (57.6%), followed by AF (23.6%). In 9.7% of recordings, the quality was too low to interpret. The most frequent clinical scenarios where PPG technology was used in the TeleCheck-AF project was a follow-up after AF ablation (1110 patients) followed by heart rate and rhythm assessment around (tele)consultation (966 patients). Conclusion: We introduce a newly developed structured stepwise practical guide on PPG signal interpretation developed based on presented experiences from TeleCheck-AF. The present clinical scenarios for the use of on-demand PPG technology derived from the TeleCheck-AF project will help to implement PPG technology in the management of AF patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA