Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
EJNMMI Res ; 13(1): 68, 2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37453996

RESUMO

BACKGROUND: For safe and effective holmium-166 (166Ho) liver radioembolization, dosimetry is crucial and requires accurate healthy liver definition. The current clinical standard relies on manual segmentation and registration of a separately acquired contrast enhanced CT (CECT), a prone-to-error and time-consuming task. An alternative is offered by simultaneous imaging of 166Ho and technetium-99m stannous-phytate accumulating in healthy liver cells (166Ho-99mTc dual-isotope protocol). This study compares healthy liver segmentation performed with an automatic method using 99mTc images derived from a 166Ho-99mTc dual-isotope acquisition to the manual segmentation, focusing on healthy liver dosimetry and corresponding hepatotoxicity. Data from the prospective HEPAR PLuS study were used. Automatic healthy liver segmentation was obtained by thresholding the 99mTc image (no registration step required). Manual segmentation was performed on CECT and then manually registered to the SPECT/CT and subsequently to the corresponding 166Ho SPECT to compute absorbed dose in healthy liver. RESULTS: Thirty-one patients (66 procedures) were assessed. Manual segmentation and registration took a median of 30 min per patient, while automatic segmentation was instantaneous. Mean ± standard deviation of healthy liver absorbed dose was 18 ± 7 Gy and 20 ± 8 Gy for manual and automatic segmentations, respectively. Mean difference ± coefficient of reproducibility between healthy liver absorbed doses using the automatic versus manual segmentation was 2 ± 6 Gy. No correlation was found between mean absorbed dose in the healthy liver and hepatotoxicity. CONCLUSIONS: 166Ho-99mTc dual-isotope protocol can automatically segment the healthy liver without hampering the 166Ho dosimetry assessment. TRIAL REGISTRATION: ClinicalTrials.gov, NCT02067988. Registered 20 February 2014. https://clinicaltrials.gov/ct2/show/NCT02067988.

2.
EJNMMI Phys ; 9(1): 30, 2022 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-35445948

RESUMO

BACKGROUND: Partition modeling allows personalized activity calculation for holmium-166 (166Ho) radioembolization. However, it requires the definition of tumor and non-tumorous liver, by segmentation and registration of a separately acquired CT, which is time-consuming and prone to error. A protocol including 166Ho-scout, for treatment simulation, and technetium-99m (99mTc) stannous phytate for healthy-liver delineation was proposed. This study assessed the accuracy of automatic healthy-liver segmentation using 99mTc images derived from a phantom experiment. In addition, together with data from a patient study, the effect of different 99mTc activities on the 166Ho-scout images was investigated. To reproduce a typical scout procedure, the liver compartment, including two tumors, of an anthropomorphic phantom was filled with 250 MBq of 166Ho-chloride, with a tumor to non-tumorous liver activity concentration ratio of 10. Eight SPECT/CT scans were acquired, with varying levels of 99mTc added to the non-tumorous liver compartment (ranging from 25 to 126 MBq). For comparison, forty-two scans were performed in presence of only 99mTc from 8 to 240 MBq. 99mTc image quality was assessed by cold-sphere (tumor) contrast recovery coefficients. Automatic healthy-liver segmentation, obtained by thresholding 99mTc images, was evaluated by recovered volume and Sørensen-Dice index. The impact of 99mTc on 166Ho images and the role of the downscatter correction were evaluated on phantom scans and twenty-six patients' scans by considering the reconstructed 166Ho count density in the healthy-liver. RESULTS: All 99mTc image reconstructions were found to be independent of the 166Ho activity present during the acquisition. In addition, cold-sphere contrast recovery coefficients were independent of 99mTc activity. The segmented healthy-liver volume was recovered fully, independent of 99mTc activity as well. The reconstructed 166Ho count density was not influenced by 99mTc activity, as long as an adequate downscatter correction was applied. CONCLUSION: The 99mTc image reconstructions of the phantom scans all performed equally well for the purpose of automatic healthy-liver segmentation, for activities down to 8 MBq. Furthermore, 99mTc could be injected up to at least 126 MBq without compromising 166Ho image quality. Clinical trials The clinical study mentioned is registered with Clinicaltrials.gov (NCT02067988) on February 20, 2014.

3.
EJNMMI Phys ; 8(1): 22, 2021 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-33651253

RESUMO

BACKGROUND: High activities of holmium-166 (166Ho)-labeled microspheres are used for therapeutic radioembolization, ideally directly followed by SPECT imaging for dosimetry purposes. The resulting high-count rate potentially impacts dead time, affecting the image quality and dosimetric accuracy. This study assesses gamma camera performance and SPECT image quality at high 166Ho activities of several GBq. To this purpose, the liver compartment, including two tumors, of an anthropomorphic phantom was filled with 166Ho-chloride, with a tumor to non-tumorous liver activity concentration ratio of 10:1. Multiple SPECT/CT scans were acquired over a range of activities up to 2.7 GBq. Images were reconstructed using a commercially available protocol incorporating attenuation and scatter correction. Dead time effects were assessed from the observed count rate in the photopeak (81 keV, 15% width) and upper scatter (118 keV, 12% width) window. Post reconstruction, each image was scaled with an individual conversion factor to match the known total activity in the phantom at scanning time. The resulting activity concentration was measured in the tumors and non-tumorous liver. The image quality as a function of activity was assessed by a visual check of the absence of artifacts by a nuclear medicine physician. The apparent lung shunt fraction (nonzero due to scatter) was estimated on planar and SPECT images. RESULTS: A 20% count loss due to dead time was observed around 0.7 GBq in the photopeak window. Independent of the count losses, the measured activity concentration was up to 100% of the real value for non-tumorous liver, when reconstructions were normalized to the known activity at scanning time. However, for tumor spheres, activity concentration recovery was ~80% at the lowest activity, decreasing with increasing activity in the phantom. Measured lung shunt fractions were relatively constant over the considered activity range. CONCLUSIONS: At high 166Ho count rate, all images, visually assessed, presented no artifacts, even at considerable dead time losses. A quantitative evaluation revealed the possibility of reliable dosimetry within the healthy liver, as long as a post-reconstruction scaling to scanning activity is applied. Reliable tumor dosimetry, instead, remained hampered by the dead time.

4.
World J Nucl Med ; 13(1): 28-33, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25191109

RESUMO

(166)Holmium-1,2-propylene di-amino tetra (methy1enephosphonicacid) ((166) Ho-PDTMP) complex was prepared successfully using an in-house synthesized PDTMP ligand and (166) HoCl 3 . Ho-166 chloride was obtained by thermal neutron irradiation (1 × 10 (13) n/cm (2) /s) of natural Ho (NO 3 ) 3 samples (specific activity = 3-5 GBq/mg), dissolved in acidic media. Radiochemical purity of (166) Ho-PDTMP was checked by instant thin layer chromatography (>99%). Stability studies of the complex in the final preparation and in the presence of human serum were performed up to 72 h. The biodistribution of (166) Ho-PDTMP and (166) HoCl 3 in wild-type rats was checked in animal tissues up to 48 h. The produced (166) Ho-PDTMP properties suggest a possible new bone palliative therapeutic to overcome the metastatic bone pains.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA