1.
Cureus ; 15(11): e48271, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38054161

RESUMO

Background The prevalence of cardiovascular disease and incidence of major adverse cardiovascular events (MACEs) is very high among the abdominal aortic aneurysm (AAA) surveillance population. Formal assessments of and interventions to reduce cardiovascular risk are not a routine part of the surveillance programme at present. However, its potential importance is highlighted by incidental findings during the AAA Get Fit Trial, a randomised controlled trial which included baseline cardiopulmonary exercise testing (CPET). We speculate that CPET can act as an opportunistic screening programme to identify cardiovascular disease in AAA surveillance patients. Methods The AAA Get Fit Trial was a prospective, randomised controlled trial at a tertiary vascular centre, Manchester University NHS Foundation Trust, conducted between November 2017 and August 2019. Patients underwent CPET at baseline, 8, 16, 24 and 36 weeks as well as clinical history and examination and blood tests. We report on incidental cardiovascular abnormalities diagnosed during the trial. Results Of the 59 participants in the trial, four (6.8%) were identified to have abnormal findings suggestive of unstable cardiovascular disease. On subsequent further investigation, two patients were diagnosed and treated for severe coronary artery disease after abnormal ECG findings were noted during CPET. One patient was diagnosed with unstable angina after obtaining a detailed history on baseline assessment which was treated medically before going on to have a successful elective AAA repair. Conclusions There is a high incidence of MACEs among this high-risk population both pre and perioperatively. Identifying and treating cardiovascular disease among the AAA surveillance population must be a focus of the future AAA screening programme.

2.
J Vasc Surg ; 74(5): 1644-1650, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33940074

RESUMO

OBJECTIVE: Conventional two-dimensional ultrasound (2D-US) has been the recommended and preferred modality for the diagnosis and surveillance of abdominal aortic aneurysms (AAAs). Measurement of the aneurysm diameter using three-dimensional ultrasound (3D-US) has shown promising results in a research setting, improving agreement and reproducibility. However, studies evaluating 3D-US in a clinical context are lacking, which could hinder the optimal usage of this new modality. In the present study, we investigated the clinical value of 3D-US for AAA surveillance compared with the current standard 2D-US examination. METHODS: Data from 126 patients with infrarenal AAAs <50 mm and 55 mm (female and male, respectively) were available for analysis. Eligibility was determined using the standard 2D-US anteroposterior (AP) diameter with a dual-plane technique. All the patients had subsequently undergone additional 3D-US and computed tomography angiography (CTA). Using CTA as the reference standard, the maximal standard 2D-US AP diameter was compared with that from 3D-US. RESULTS: All 126 AAAs were, per the inclusion criteria, small, with no intervention indicated. With the addition of 3D-US imaging to the 2D-US-based surveillance program, the AAA diameter threshold (50 and 55 mm) was exceeded for 31 of the 126 patients (25%). These 31 patients were withdrawn from the present study and referred for treatment planning. Compared with the CTA AP diameter (mean, 49 ± 7.2 mm), the mean 3D-US AP diameter (mean, 49 ± 6.7 mm) was significantly more accurate than the standard mean 2D-US AP diameter (45 ± 6.2 mm; kappa value, 0.86 ± 0.05; 95% confidence interval, 0.76-0.96; kappa value, 0.01 ± 0.04; 95% confidence interval, -0.05 to 0.09, respectively). CONCLUSIONS: For clinical use, the AAA diameter assessment using 3D-US was significantly more accurate than that with 2D-US and can substantially change the clinical management, from surveillance to operative treatment, for approximately one fourth of patients with an AAA. Further studies evaluating the clinical consequences of the 2D to 3D paradigm shift in AAA diagnostics are warranted, including sensitivity, specificity, agreement, and reproducibility estimation.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Imageamento Tridimensional , Ultrassonografia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/cirurgia , Aortografia , Tomada de Decisão Clínica , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo
3.
Eur J Vasc Endovasc Surg ; 54(4): 439-445, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28765014

RESUMO

OBJECTIVES: Rupture risk in abdominal aortic aneurysms (AAAs) is assessed using AAA diameter; yet 10% of ruptures occur in a small aneurysm. This underlines the inadequacy of diameter as a standalone parameter. In this prospective follow-up study, ultrasound determined aneurysm diameter was compared with aneurysm volume determined by three dimensional ultrasound (3D-US) in a group of 179 AAAs. DESIGN: This was a prospective cohort study with repeated diameter and volume measurements by 3D-US. MATERIAL AND METHODS: In total, 179 patients with small infrarenal AAAs (diameter 30-55 mm) were enrolled consecutively. At enrolment and at 12 month follow-up, maximum diameter, using dual plane technique, and three dimensional volume were measured. Based on a previous accuracy study, significant change in diameter and volume were defined as an increase exceeding the known range of variability (ROV) of each US technique; ±3.7 mm and ±8.8 mL, respectively. Post-hoc Kaplan-Meier analysis was performed to estimate time to conversion to treatment after the conclusion of the follow-up period between two groups. RESULTS: In total, 125 patients (70%) had an unchanged diameter during follow-up. In this group, 50 patients (40%) had an increasing aortic volume. Forty-five (83%) of the 54 patients with an increasing aortic diameter showed a corresponding volume increase. During a median follow-up of 367 days (364-380 days), a mean increase in diameter of 2.7 mm (±2.6 mm) and a mean increase in volume of 11.6 mL (±9.9 mL) were recorded. In post-hoc analysis, it was found that more AAAs with a stable diameter and a growing volume than AAAs with a stable diameter and volume were undergoing aortic repair during follow-up, based on the maximum diameter. CONCLUSION: In this cohort of small AAAs, 40% of patients with a stable diameter had an increasing volume at 12 month follow-up. From this perspective, 3D-US could have a future supplemental role in AAA surveillance programmes.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Imageamento Tridimensional , Ultrassonografia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/cirurgia , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Prospectivos , Conduta Expectante