Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.249
Filtrar
1.
Anim Sci J ; 95(1): e14002, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39352220

RESUMO

With the development of wearable devices, it is now possible to monitor livestock behavior 24 h a day. In this study, we estimated the genetic parameters of the daily duration of six behaviors (feeding, moving, lying, standing, ruminating while lying, and ruminating while standing) in beef cattle, automatically classified using wearable devices. The devices were attached to 332 Japanese beef cattle at two stations for approximately 5 months. We compared repeatability, Poisson regression, and random regression models using the deviance information criterion. Poisson regression models were selected for all traits at each station, probably because of the non-normal distribution of the phenotypes. The heritability estimates by the Poisson regression models were moderate at each station: 0.67 and 0.68 for feeding, 0.68 and 0.53 for moving, 0.47 and 0.55 for lying, 0.45 and 0.40 for standing, 0.51 and 0.59 for ruminating while lying, and 0.37 and 0.45 for ruminating while standing. The genetic correlations between these traits were all negative at both stations, whereas the residual correlations showed different directions depending on the station. Although validation studies with larger populations are needed to confirm these findings, this study provides fundamental knowledge of the genetic basis of daily behavior in beef cattle.


Assuntos
Comportamento Animal , Dispositivos Eletrônicos Vestíveis , Animais , Bovinos/genética , Característica Quantitativa Herdável , Distribuição de Poisson , Fenótipo , Masculino , Feminino
2.
BMJ Open Sport Exerc Med ; 10(4): e001954, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39381414

RESUMO

Objective: To examine the likelihood of head acceleration events (HAEs) as a function of previously identified risk factors: match time, player status (starter or substitute) and pitch location in elite-level men's and women's rugby union matches. Methods: Instrumented mouthguard data were collected from 179 and 107 players in the men's and women's games and synchronised to video-coded match footage. Head peak resultant linear acceleration (PLA) and peak resultant angular acceleration were extracted from each HAE. Field location was determined for HAEs linked to a tackle, carry or ruck. HAE incidence was calculated per player hour across PLA recording thresholds with 95% CIs estimated. Propensity was calculated as the percentage of contact events that caused HAEs across PLA recording thresholds, with a 95% CI estimated. Significance was assessed by non-overlapping 95% CIs. Results: 29 099 and 6277 HAEs were collected from 1214 and 577 player-matches in the men's and women's games. No significant differences in match quarter HAE incidence or propensity were found. Substitutes had higher HAE incidence than starters at lower PLA recording thresholds for men but similar HAE propensity. HAEs were more likely to occur in field locations with high contact event occurrence. Conclusion: Strategies to reduce HAE incidence need not consider match time or status as a substitute or starter as HAE rates are similar throughout matches, without differences in propensity between starters and substitutes. HAE incidence is proportional to contact frequency, and strategies that reduce either frequency or propensity for contact to cause head contact may be explored.

3.
J Sports Sci ; : 1-9, 2024 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-39383318

RESUMO

The study objectives were 1) to determine the feasibility and acceptability of indoor activities to achieve moderate-to-vigorous physical activity (MVPA) in preschoolers, and 2) compare MVPA estimates between direct observation (DO) and various accelerometry placements. In this cross-sectional study, 35 preschoolers (51% female, 54% 3-year-olds) performed six, 6-minute activities (dancing to video, balloon/bubbles, stationary exergame cycling, circuits, running-in-place, and cleaning up) in sequential order, facilitated by a trained staff member. Triaxial accelerometers (Actigraph Gt3×BT) at the ankle, waist, and wrist measured MVPA using age-specific cut-points. Total activity and MVPA time were quantified via DO of video recordings. Feasibility and acceptability were assessed via parent and child report. Preschoolers contributed 4339, 15-second epochs of accelerometry and DO data (~31.0 minutes/preschooler). Preschoolers achieved MVPA ≥ 50% of the time while engaging in balloon/bubbles, cycling, and circuits; but not while dancing to video (15%), running-in-place (48.5%), or cleaning up (8%). There were no differences in MVPA by age, sex, or between screen and non-screen activities. Parents and preschoolers reported most activities were feasible (≥4.0/5.0). Waist and ankle accelerometry had strong agreement with DO (ICCs range: 0.70-0.84) while wrist had fair to low agreement (ICCs: 0.22-0.58). Multiple indoor activities show promise to increase preschoolers' MVPA.

4.
Front Pediatr ; 12: 1463288, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39363968

RESUMO

Background and objective: Physical activity (PA) is paramount for childhood development and growth. However, children diagnosed with Cerebral Palsy (CP) were often considered sedentary, and their physical inactivity was associated with adverse health conditions and complications. Therefore, this study aimed to objectively describe and compare the PA levels and SB levels of children with and without CP of the same age group. It also studied the factors correlating with PA, SB, and step count per day in children with CP. Subjects and methods: A cross-sectional study using a wrist-worn accelerometer was conducted. PA and SB were measured over seven consecutive days. Results: Eighty-five children aged 6-12 years, consisting of 41 children with CP and 44 TD children, participated in this study with a mean age of 9.18 ± 1.95 and 8.45 ± 1.78 years, respectively. According to the gross functional measures, 53.6% of children with CP were classified as first classification. A significant amount of time was spent in SB and Light PA (LPA) by children with CP compared to TD children, and no significant differences were observed in moderate PA (MPA) or step count. Gender mainly affected MPA as girls spent more time in MPA than boys. The age, height, and weight of children with CP correlate significantly with SB. As children's age, height, and weight increase, SB increases. Additionally, children with higher weights have lower step counts per day. Conclusion: This study showed that children with CP spend more time in LPA and SB than typically developed children. Therefore, concerted efforts are needed to encourage physical activity and reduce the sedentary lifestyle, to take into account the gender and anthropometric measures of children to enhance the quality of life among children with CP, and to consider gender and anthropometric measures of the children.

5.
BMC Sports Sci Med Rehabil ; 16(1): 212, 2024 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-39390591

RESUMO

BACKGROUND: The development of readily available wearable accelerometers has enabled clinicians to objectively monitor physical activity (PA) remotely in the community, a superior alternative to patient self-reporting measures. Critical to the value of these monitors is the ability to reliably detect when patients are undergoing ambulatory activity. Previous studies have highlighted the strength of using mean amplitude deviation (MAD) as a universal measure for analysing raw accelerometery data and defining cut-points between sedentary and ambulatory activities. Currently however there is little evidence surrounding the use of chest-worn accelerometers which can provide simultaneous monitoring of other physiological parameters such as heart rate (HR), RR intervals, and Respiratory Rate alongside accelerometery data. We aimed to calibrate the accelerometery function within the VivaLink ECG patch to determine the cut-point MAD value for differentiating sedentary and ambulatory activities. METHODS: We recruited healthy volunteers to undergo a randomised series of 9 activities that simulate typical free-living behaviours, while wearing a VivaLink ECG Patch (Campbell, California). MAD values were applied to a Generalised Linear Mixed Model to determine cut-points between sedentary and ambulatory activities. We constructed a Receiver Operating Characteristic (ROC) curve to analyse the sensitivity and specificity of the cut-off MAD value. RESULTS: Eighteen healthy adults volunteered to the study and mean MAD values were collected for each activity. The optimal MAD cut-point between sedentary and ambulatory activities was 47.73mG. ROC curve analysis revealed an area under the curve of 0.99 (p < 0.001) for this value with a sensitivity and specificity of 98% and 100% respectively. CONCLUSION: In conclusion, the MAD cut-point determined in our study is very effective at categorising sedentary and ambulatory activities among healthy adults and may be of use in monitoring PA in the community with minimal burden. It will also be useful for future studies aiming to simultaneously monitor PA with other physiological parameters via chest worn accelerometers.

6.
Int J Behav Nutr Phys Act ; 21(1): 107, 2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-39327609

RESUMO

BACKGROUND: Despite the observed associations of personality traits with levels of moderate-to-vigorous physical activity (MVPA) and sedentary behavior (SB), studies exploring whether the personality profiles differ in terms of the pattern of accumulation of physical behavior are lacking. The aim of this study was to identify adults' personality profiles and to characterize and investigate how these profiles differ in physical behavior. METHODS: The study utilized the longitudinal data of the participants of the Jyväskylä Longitudinal Study of Personality and Social Development (n = 141-307). Information on the five-factor model of personality, including the traits of neuroticism, extraversion, conscientiousness, openness, and agreeableness, was collected at ages 33, 42, 50, and 61 years, and used to create latent personality profiles. Physical behavior, operationalized as the amount and accumulation of MVPA and SB bouts, was captured using a triaxial accelerometer worn during waking hours at age 61 years. The differences in the behavior between the personality profiles were analyzed using the Kruskal-Wallis test. RESULTS: Five personality profiles were identified: resilient (20.2%), brittle (14.0%), overcontrolled (9.8%), undercontrolled (15.3%), and ordinary (40.7%). Although there were no statistically significant differences between the personality profiles in the time spent in MVPA relative to SB (MVPA per hour of daily SB), individuals with resilient (low in neuroticism and high in other traits) and ordinary (average in each trait) profiles had MVPA-to-SB ratios of 0.12 (7 min) and those with a brittle (high in neuroticism and low in extraversion) profile had a ratio of 0.09 (5.5 min). The individuals in the resilient group exhibited a longer usual MVPA bout duration than those in the overcontrolled (low in extraversion, openness, and agreeableness) (8 min vs. 2 min) and undercontrolled (high in openness and low in conscientiousness) groups (8 min vs. 3 min). They also exhibited a longer usual SB bout duration than those in the ordinary group (29 min vs. 23 min). CONCLUSIONS: The resilient group displayed the most prolonged MVPA and SB bout patterns. The results suggest that personality characteristics may contribute to how MVPA and SB are accumulated.


Assuntos
Exercício Físico , Personalidade , Comportamento Sedentário , Humanos , Exercício Físico/psicologia , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto , Estudos Longitudinais , Acelerometria , Finlândia , Comportamentos Relacionados com a Saúde
7.
Int J Behav Nutr Phys Act ; 21(1): 106, 2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-39327627

RESUMO

BACKGROUND: The PROMIS® Early Childhood Physical Activity (PROMIS EC PA) scale is a recently developed PROMIS Early Childhood measure to assess PA among children aged 1-5 years. The purpose of this study was to examine test-retest reliability and convergent validity of the PROMIS EC PA scale among toddlers. METHOD: An ancillary study was conducted in the toddler-mother dyad sample of the Child and Mother Physical Activity Study. Mothers completed the 7-item PROMIS EC PA scale twice: during a study visit (test) and on the last day when their child's wore an ActiGraph accelerometer on the hip for 7 days (retest). The PROMIS EC PA summed score was calculated by totaling scores from items 1-5. Test-retest reliability was assessed using intraclass correlation coefficient (ICC) for test and retest PROMIS EC PA. Convergent validity was assessed using rank correlation coefficients (rho) between PROMIS EC PA scores and accelerometer-measured moderate- and vigorous-intensity PA (MVPA). RESULTS: Among 74 participants (56% female; 19 ± 4 months of mean age with range of 12-30 months), average accelerometer-measured MVPA was 76 ± 24 min/day. The median number of days between PROMIS EC PA test and retest was 8 days (IQR = 6 to 8), with an average PROMIS EC PA summed score of 11.0 ± 3.5 at test and 10.5 ± 3.4 at retest. ICC for the test-retest PROMIS EC PA summed scores was 0.72 (95% CI = 0.59-0.82). The rank correlation between the PROMIS EC PA summed score and accelerometer-measured MVPA was 0.13 (95% CI=-0.10 to 0.35; p = 0.28). CONCLUSION: In a sample of children aged 12-30 months, test-retest reliability for the PROMIS EC PA scale was moderate and its convergent validity against accelerometer-measured MVPA was poor. Prior to a widespread use of the PROMIS EC PA scale in large-scale research and clinical practice, the tool should be further refined and validated to elucidate how young children's lived PA experience as measured in the PROMIS EC PA scale is relevant to their health and wellbeing outcomes.


Assuntos
Acelerometria , Exercício Físico , Mães , Humanos , Feminino , Reprodutibilidade dos Testes , Pré-Escolar , Masculino , Acelerometria/métodos , Lactente , Inquéritos e Questionários/normas , Adulto
8.
Proc Inst Mech Eng H ; : 9544119241281976, 2024 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-39344183

RESUMO

An asymmetric windswept posture is often seen in children with severe cerebral palsy (CP). However, it is still unclear how long children with CP remain in the windswept posture in daily life. Thus, we developed a triple-accelerometer system for detecting windswept posture. The aim of this study was to assess the validity of a system for classifying various body postures and movements. We assessed the accuracy of our system in nine healthy young adults (age range, 21-23 years). The participants wore acceleration monitors on the sternum and both thighs, then spent 3 min each in eight different positions and three physical activities. Once accuracy was confirmed, we assessed the posture and movements for 24 h in six healthy young adults (age range, 21-23 years) in their home environments. The body postures and activities were correctly detected: the agreement across the subjects were 100% compatible with the subjects' activity logs at least 68% of the time, and at least 96% of the time for recumbent positions. We concluded that the proposed monitoring system is a reliable and valid approach for assessing windswept hip posture in a free-living setting.

9.
J Sports Sci ; : 1-10, 2024 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-39340399

RESUMO

The aim was to assess concurrent validity and test-retest reliability of spatiotemporal gait parameters from a thoracic-placed inertial measurement unit (IMU) in lab- (Phase One) and field-based (Phase Two) conditions. Spatiotemporal gait parameters were compared (target speeds 3, 5 and 7.5 m·s-1) between a 100 Hz IMU and an optical measurement system (OptoJump Next, 1000 hz) in 14 trained individuals (Phase One). Additionally, 29 English Premier League football players performed weekly 3 × 60 m runs (5 m·s-1; observations = 1227; Phase Two). Mixed effects modelling assessed the effect of speed on agreement between systems (Phase One) and test-retest reliability (Phase Two). IMU step time showed strong agreement (<0.3%) regardless of individual or running speed. Direction of mean biases up to 40 ms for contact and flight time depended on the running speed and individual. Step time, length and frequency were most reliable (coefficient of variation = 1.3-1.4%) but confounded by running speed. Step time, length and frequency derived from a thoracic-placed IMU can be used confidently. Contact time could be used if bias is corrected for each individual. To optimise test-retest reliability, a minimum running distance of 40 m is needed to ensure 10 constant-speed steps is gathered.

10.
Micromachines (Basel) ; 15(9)2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39337791

RESUMO

Temperature exerts a profound influence on the fidelity of photosensors, making the attainment of reliable temperature compensation a formidable task within engineering realms. This research delves into the intricacies of photosensors used in high-precision accelerometers, proposing an innovative, high-precision, adaptive, closed-loop compensation mechanism. Our design stands in stark contrast to traditional open-loop models, demonstrating superior performance by achieving a remarkable reduction in compensation error-nearly 98%. This advancement in consistency and precision marks a significant leap forward for the application of high-precision photosensors in engineering contexts.

11.
Micromachines (Basel) ; 15(9)2024 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-39337833

RESUMO

This paper reports the design, fabrication, and characterization of a MEMS capacitive accelerometer with an asymmetrical comb finger arrangement. By optimizing the ratio of the gaps of a rotor finger to its two adjacent stator fingers, the sensitivity of the accelerometer is maximized for the same comb finger area. With the fingers' length, width, and depth at 120 µm, 4 µm, and 45 µm, respectively, the optimized finger gap ratio is 2.5. The area of the proof mass is 750 µm × 560 µm, which leads to a theoretical thermomechanical noise of 9 µg/√Hz. The accelerometer has been fabricated using a modified silicon-on-glass (SOG) process, in which a groove is pre-etched into the glass to hold the metal electrode. This SOG process greatly improves the silicon-to-glass bonding yield. The measurement results show that the resonant frequency of the accelerometer is about 2.05 kHz, the noise floor is 28 µg/√Hz, and the nonlinearity is less than 0.5%.

12.
BMC Med ; 22(1): 398, 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39289727

RESUMO

BACKGROUND: The liver effects of concentrated vs. more evenly distributed moderate-to-vigorous physical activity (MVPA) patterns remain unclear. We aimed to examine the association of accelerometer-measured MVPA and different MVPA patterns with liver outcomes. METHODS: Eighty-eight thousand six hundred fifty-six participants without prior liver diseases from UK Biobank were included. MVPA was measured by a wrist-worn accelerometer. Based on the guideline-based threshold (≥ 150 min/week), MVPA patterns were defined as inactive (< 150 min/week), active weekend warrior (WW; ≥ 150 min/week with ≥ 50% of total MVPA achieved within 1-2 days), and regularly active (≥ 150 min/week but not active WW) patterns. The primary outcome was incident nonalcoholic fatty liver disease (NAFLD). RESULTS: During a median follow-up of 6.8 years, 562 participants developed NAFLD. Overall, there was a nonlinear inverse association of total MVPA with incident NAFLD (P for nonlinearity = 0.009): the risk of NAFLD rapidly decreased with the increment of MVPA (per 100 min/week increment: HR = 0.68; 95%CI, 0.57-0.81) when MVPA < 208 min/week, while moderately declined (HR = 0.91; 95%CI, 0.84-0.99) when MVPA ≥ 208 min/week. For MVPA patterns, compared with inactive group, both active WW (HR = 0.55, 95%CI, 0.44-0.67) and active regular (HR = 0.49, 95%CI, 0.38-0.63) group were associated with a similar lower risk of NAFLD. Similar results were observed for each secondary outcome, including incident severe liver diseases, incident liver cirrhosis, and liver magnetic resonance imaging-based liver steatosis and fibrosis. CONCLUSIONS: Regardless of whether MVPA was concentrated within 1 to 2 days or spread over most days of the week, more MVPA was associated with a lower risk of incident liver outcomes, including NAFLD, liver cirrhosis, liver steatosis, and fibrosis, to MVPA more evenly distributed.


Assuntos
Acelerometria , Exercício Físico , Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Masculino , Feminino , Pessoa de Meia-Idade , Exercício Físico/fisiologia , Adulto , Idoso , Incidência , Reino Unido/epidemiologia
13.
Front Public Health ; 12: 1412634, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39296832

RESUMO

Background: Physical activity (PA), sedentary behavior (SB), and sleep are collectively referred to as 24-h movement behaviors, which may be linked to cognitive development in children. However, most of the evidence was based on cross-sectional studies and/or solely relied on parent-reported information on children's behaviors, and it remains uncertain whether all domains/contexts of PA and SB are similarly associated with executive function and academic achievement. Objective: We investigated the prospective associations of accelerometer-measured 24 h-movement behaviors and domain-specific PA and SB with executive function and academic achievement among school-aged children in Singapore. Methods: The Growing Up in Singapore Toward healthy Outcomes (GUSTO) cohort used a wrist-worn accelerometer (Actigraph-GT3x+) to measure 24 h-movement behaviors data at ages 5.5 and 8 years. Executive function and academic achievement were assessed using NEuroPSYchology (NEPSY) and Wechsler Individual Achievement Tests at ages 8.5 and 9-years, respectively. Compositional data analyses were conducted to explore the associations of 24 h-movement behavior with outcomes, and multiple linear regression models to examine the associations of domain-specific PA and SB with outcomes (n = 432). Results: Among 432 children whose parents agreed to cognitive assessments (47% girls and 58% Chinese), the composition of 24 h-movement behaviors at ages 5.5 and 8 years was not associated with executive function and academic achievement. However, higher moderate-to-vigorous PA (MVPA) relative to remaining movement behaviors at age 5.5 years was associated with lower academic achievement [Mean difference (95% confidence interval): -0.367 (-0.726, -0.009) z-score], and reallocating MVPA time to sleep showed higher academic achievement scores [30 min from MVPA to sleep: 0.214 (0.023, 0.404) z-score]. Certain domains of PA and SB, notably organized PA/sports, outdoor play, and reading books were favorably associated with outcomes of interest, while indoor play and screen-viewing were unfavorably associated. Conclusion: The associations between movement behaviors and cognitive outcomes are multifaceted, influenced by specific domains of PA and SB. This study underscores the importance of participation in organized PA/sports, outdoor active play, and reading books, while ensuring adequate sleep and limiting screen viewing, to enhance cognitive outcomes. These findings underscore the need for further research into time-use trade-offs. Such studies could have major implications for revising current guidelines or strategies aimed at promoting healthier 24 h-movement behaviors in children. Study registration: https://clinicaltrials.gov/, NCT01174875.


Assuntos
Sucesso Acadêmico , Acelerometria , Função Executiva , Exercício Físico , Comportamento Sedentário , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Função Executiva/fisiologia , Exercício Físico/psicologia , Estudos Prospectivos , Singapura , Sono/fisiologia
14.
Sensors (Basel) ; 24(17)2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39275629

RESUMO

There is limited validation for portable methods in evaluating high-speed running biomechanics, with inertial measurement unit (IMU) systems commonly used as wearables for this purpose. This study aimed to evaluate the validity of an IMU system in high-speed running compared to a 3D motion analysis system (MAS). One runner performed incremental treadmill running, from 12 to 18 km/h, on two separate days. Sagittal angles for the shank, knee, hip and pelvis were measured simultaneously with three IMUs and the MAS at the point of contact (POC), the timing when the foot initially hits the ground, as identified by IMU system acceleration, and compared to the POC identified via force plate. Agreement between the systems was evaluated using intra-class correlation coefficients, Pearson's r, Bland-Altman limits of agreements, root mean square error and paired t-tests. The IMU system reliably determined POC (which subsequently was used to calculate stride time) and measured hip flexion angle and anterior pelvic tilt accurately and consistently at POC. However, it displayed inaccuracy and inconsistency in measuring knee flexion and shank angles at POC. This information provides confidence that a portable IMU system can aid in establishing baseline running biomechanics for performance optimisation, and/or inform injury prevention programs.


Assuntos
Extremidade Inferior , Corrida , Humanos , Corrida/fisiologia , Fenômenos Biomecânicos/fisiologia , Extremidade Inferior/fisiologia , Masculino , Adulto , Dispositivos Eletrônicos Vestíveis
15.
Sensors (Basel) ; 24(17)2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39275628

RESUMO

Overnight sleep staging is an important part of the diagnosis of various sleep disorders. Polysomnography is the gold standard for sleep staging, but less-obtrusive sensing modalities are of emerging interest. Here, we developed and validated an algorithm to perform "proxy" sleep staging using cardiac and respiratory signals derived from a chest-worn accelerometer. We collected data in two sleep centers, using a chest-worn accelerometer in combination with full PSG. A total of 323 participants were analyzed, aged 13-83 years, with BMI 18-47 kg/m2. We derived cardiac and respiratory features from the accelerometer and then applied a previously developed method for automatic cardio-respiratory sleep staging. We compared the estimated sleep stages against those derived from PSG and determined performance. Epoch-by-epoch agreement with four-class scoring (Wake, REM, N1+N2, N3) reached a Cohen's kappa coefficient of agreement of 0.68 and an accuracy of 80.8%. For Wake vs. Sleep classification, an accuracy of 93.3% was obtained, with a sensitivity of 78.7% and a specificity of 96.6%. We showed that cardiorespiratory signals obtained from a chest-worn accelerometer can be used to estimate sleep stages among a population that is diverse in age, BMI, and prevalence of sleep disorders. This opens up the path towards various clinical applications in sleep medicine.


Assuntos
Acelerometria , Algoritmos , Polissonografia , Fases do Sono , Humanos , Pessoa de Meia-Idade , Adulto , Idoso , Acelerometria/instrumentação , Acelerometria/métodos , Masculino , Feminino , Adolescente , Idoso de 80 Anos ou mais , Polissonografia/métodos , Fases do Sono/fisiologia , Adulto Jovem , Tórax
16.
J Appl Biomech ; 40(5): 437-443, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39222917

RESUMO

Smartphones, with embedded accelerometers, may be a viable method to monitor gait variability in the free-living environment. However, measurements estimated using smartphones must first be compared to known quantities to ensure validity. This study assessed the validity and reliability of smartphone-derived gait measures compared to a gold-standard footswitch system during overground walking. Seventeen adults completed three 8-minute overground walking trials during 3 separate visits. The stride time series was calculated as the time difference between consecutive right heel contact events within the footswitch and smartphone-accelerometry signals. Linear (average stride time, stride time standard deviation, and stride time coefficient of variation) and nonlinear (fractal scaling index, approximate entropy, and sample entropy) measures were calculated for each stride time series. Bland-Altman plots with 95% limits of agreement assessed agreement between systems. Intraclass correlation coefficients assessed reliability across visits. Bland-Altman plots revealed acceptable limits of agreement for all measures. Intraclass correlation coefficients revealed good-to-excellent reliability for both systems, except for fractal scaling index, which was moderate. The smartphone system is a valid method and performs similarly to gold-standard research equipment. These findings suggest the development and implementation of an inexpensive, easy-to-use, and ubiquitous telehealth instrument that may replace traditional laboratory equipment for use in the free-living environment.


Assuntos
Acelerometria , Marcha , Smartphone , Caminhada , Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Adulto , Acelerometria/instrumentação , Marcha/fisiologia , Caminhada/fisiologia , Análise da Marcha/instrumentação , Análise da Marcha/métodos
17.
JMIR Hum Factors ; 11: e59659, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39226099

RESUMO

BACKGROUND: Health-related quality of life (HRQoL) reflects an individual's perception of their physical and mental health over time. Despite numerous studies linking physical activity to improved HRQoL, most rely on self-reported data, limiting the accuracy and generalizability of findings. This study leverages objective accelerometer data to explore the association between physical activity and HRQoL in Korean adults. OBJECTIVE: The objective of this study is to analyze the relationship between objectively measured physical activity using accelerometers and HRQoL among Korean adults, aiming to inform targeted interventions for enhancing HRQoL through physical activity. METHODS: This observational study included 1298 participants aged 19-64 years from the Korea National Health and Nutrition Examination Survey (KNHANES) VI, who wore an accelerometer for 7 consecutive days. HRQoL was assessed using the EQ-5D questionnaire, and physical activity was quantified as moderate-to-vigorous physical activity accelerometer-total (MVPA-AT) and accelerometer-bout (MVPA-AB). Data were analyzed using logistic regression to determine the odds ratio (ORs) for low HRQoL, adjusting for socioeconomic variables and mental health factors. RESULTS: Participants with higher HRQoL were younger, more likely to be male, single, highly educated, employed in white-collar jobs, and had higher household incomes. They also reported less stress and better subjective health status. The high HRQoL group had significantly more participants meeting MVPA-AB ≥600 metabolic equivalents (P<.01). Logistic regression showed that participants meeting MVPA-AB ≥600 metabolic equivalents had higher odds of high HRQoL (OR 1.55, 95% CI 1.11-2.17). Adjusted models showed consistent results, although the association weakened when adjusting for mental health factors (OR 1.45, 95% CI 1.01-2.09). CONCLUSIONS: The study demonstrates a significant association between HRQoL and moderate to vigorous physical activity sustained for at least 10 minutes, as measured by accelerometer. These findings support promoting physical activity, particularly sustained moderate to vigorous activity, to enhance HRQoL. Further interventional studies focusing on specific physical activity domains such as occupational, leisure-time, and commuting activities are warranted.


Assuntos
Acelerometria , Exercício Físico , Inquéritos Nutricionais , Qualidade de Vida , Humanos , Masculino , República da Coreia/epidemiologia , Adulto , Qualidade de Vida/psicologia , Exercício Físico/psicologia , Feminino , Pessoa de Meia-Idade , Adulto Jovem , Inquéritos e Questionários
18.
Int J Sports Physiol Perform ; : 1-4, 2024 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-39255956

RESUMO

BACKGROUND: The optimization of athlete training load is not a new concept; however in recent years, the concept of "load management" is one of the most widely studied and divisive topics in sports science and medicine. PURPOSE: Discuss the challenges faced by sports when utilizing training load monitoring and management, with a specific focus on the use of data to inform load management guidelines and policies/mandates, their consequences, and how we move this field forward. CHALLENGES: While guidelines can theoretically help protect athletes, overzealous and overcautious guidelines may restrict an athlete's preparedness, negatively influence performance, and increase injury risk. Poor methods, wrong interpretation of study findings, and faulty logic do not allow for systematic scientific evaluations to inform guidelines. Practical Solutions: Guidelines and mandates should be developed through a systematic research process with stronger research designs and clear research questions. Collaborating with statistical and epidemiological experts is essential. Implementing open science principles and sharing all sports training load data increase transparency and allow for more rapid and valid advancements in knowledge. Practitioners should incorporate multiple data streams and consider individual athlete responses, rather than applying broad guidelines based on average data. CONCLUSION: Many current training load guidelines and mandates in sports come from good intentions; however, they are arbitrary without sound knowledge of the underlying scientific principles or methods. Common sense guidelines are helpful when there is sparse literature, but they should be careful to avoid arbitrarily choosing findings from weak research. Without precise scientific inquiries, implementing training load interventions or guidelines can have negative implications.

19.
Sci Rep ; 14(1): 20854, 2024 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-39242792

RESUMO

Progressive gait impairment is common among aging adults. Remote phenotyping of gait during daily living has the potential to quantify gait alterations and evaluate the effects of interventions that may prevent disability in the aging population. Here, we developed ElderNet, a self-supervised learning model for gait detection from wrist-worn accelerometer data. Validation involved two diverse cohorts, including over 1000 participants without gait labels, as well as 83 participants with labeled data: older adults with Parkinson's disease, proximal femoral fracture, chronic obstructive pulmonary disease, congestive heart failure, and healthy adults. ElderNet presented high accuracy (96.43 ± 2.27), specificity (98.87 ± 2.15), recall (82.32 ± 11.37), precision (86.69 ± 17.61), and F1 score (82.92 ± 13.39). The suggested method yielded superior performance compared to two state-of-the-art gait detection algorithms, with improved accuracy and F1 score (p < 0.05). In an initial evaluation of construct validity, ElderNet identified differences in estimated daily walking durations across cohorts with different clinical characteristics, such as mobility disability (p < 0.001) and parkinsonism (p < 0.001). The proposed self-supervised method has the potential to serve as a valuable tool for remote phenotyping of gait function during daily living in aging adults, even among those with gait impairments.


Assuntos
Acelerometria , Marcha , Aprendizado de Máquina Supervisionado , Humanos , Idoso , Masculino , Feminino , Marcha/fisiologia , Acelerometria/métodos , Acelerometria/instrumentação , Idoso de 80 Anos ou mais , Atividades Cotidianas , Punho , Algoritmos , Dispositivos Eletrônicos Vestíveis , Pessoa de Meia-Idade
20.
Comput Biol Med ; 182: 109090, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39232406

RESUMO

Silent speech interfaces (SSIs) have emerged as innovative non-acoustic communication methods, and our previous study demonstrated the significant potential of three-axis accelerometer-based SSIs to identify silently spoken words with high classification accuracy. The developed accelerometer-based SSI with only four accelerometers and a small training dataset outperformed a conventional surface electromyography (sEMG)-based SSI. In this study, motivated by the promising initial results, we investigated the feasibility of synthesizing spoken speech from three-axis accelerometer signals. This exploration aimed to assess the potential of accelerometer-based SSIs for practical silent communication applications. Nineteen healthy individuals participated in our experiments. Five accelerometers were attached to the face to acquire speech-related facial movements while the participants read 270 Korean sentences aloud. For the speech synthesis, we used a convolution-augmented Transformer (Conformer)-based deep neural network model to convert the accelerometer signals into a Mel spectrogram, from which an audio waveform was synthesized using HiFi-GAN. To evaluate the quality of the generated Mel spectrograms, ten-fold cross-validation was performed, and the Mel cepstral distortion (MCD) was chosen as the evaluation metric. As a result, an average MCD of 5.03 ± 0.65 was achieved using four optimized accelerometers based on our previous study. Furthermore, the quality of generated Mel spectrograms was significantly enhanced by adding one more accelerometer attached under the chin, achieving an average MCD of 4.86 ± 0.65 (p < 0.001, Wilcoxon signed-rank test). Although an objective comparison is difficult, these results surpass those obtained using conventional SSIs based on sEMG, electromagnetic articulography, and electropalatography with the fewest sensors and a similar or smaller number of sentences to train the model. Our proposed approach will contribute to the widespread adoption of accelerometer-based SSIs, leveraging the advantages of accelerometers like low power consumption, invulnerability to physiological artifacts, and high portability.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA