Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
MHSalud ; 19(2)dic. 2022.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1405521

RESUMO

Abstract The quantification of training load has become mandatory for coaches and team staff. Within the analyzed variables, distance covered at different speed zones is one of the most studied. However, there is no consensus in the definition of speed zones in the published articles about each team sport, so it makes difficult a comparison between them. Therefore, the purposes of this article were to establish a criteria standard in the classification of speed zones in team sports and to analyze its practical application in basketball. Five speed categories were established for basketball following the methodology described above: 0-10km/h, >10-13.8 km/h, >13.8-17.6 km/h, >17.6-21.5 km/h, and >21.5 km/h. The results showed differences between periods in high-speed displacements and sprints, maximum speed, total decelerations, and accelerations. In conclusion, the categorization of workload based on standard deviation according to maximum speed could be a viable option to individualize the analysis of distance covered per speeds in team sports such as basketball. Its use may lead to a better understanding and contextualization of the locomotion data in specific sports and teams.


Resumen La cuantificación de la carga de entrenamiento se ha convertido en una obligación para el personal entrenador y el personal técnico en los deportes de equipo. Dentro de las variables analizadas, la distancia recorrida en distintas zonas de velocidad es una de las más estudiadas. Sin embargo, no existe consenso en la definición de zonas de velocidad en los artículos publicados sobre cada uno de estos deportes, por lo que dificulta la comparación entre ellos. Por tanto, los objetivos de este artículo fueron establecer un criterio estándar en la clasificación de zonas de velocidad en los deportes de equipo y analizar su aplicación práctica en baloncesto. Se establecieron cinco categorías de velocidad para el baloncesto siguiendo la metodología descrita anteriormente: 0-10 km/h, >10-13,8 km/h, >13,8-17,6 km/h, >17,6-21,5 km/h y >21,5 km/h. Los resultados muestran entre períodos en desplazamientos de alta velocidad y esprints, velocidad máxima, desaceleraciones y aceleraciones totales. En conclusión, la categorización de las demandas basadas en la desviación estándar, según la velocidad máxima, podría ser una opción viable para individualizar el análisis de la distancia recorrida por velocidades en deportes de equipo como el baloncesto. Su utilización puede ayudar a una mejor comprensión y contextualización de los datos de desplazamientos en deportes y equipos específicos.


Resumo A quantificação da carga de treinamento se tornou uma obrigação para treinadores e pessoal técnico em esportes coletivos. Entre as variáveis analisadas, a distância percorrida em diferentes zonas de velocidade é uma das mais estudadas. Entretanto, não há consenso na definição de zonas de velocidade nos artigos publicados sobre cada esporte coletivo, o que torna difícil a comparação entre eles. Portanto, os objetivos deste artigo eram estabelecer um critério padrão na classificação das zonas de velocidade nos esportes coletivos e analisar sua aplicação prática no basquetebol. Foram estabelecidas cinco categorias de velocidade para o basquetebol seguindo a metodologia descrita acima: 0-10 km/h, >10-13,8 km/h, >13,8-17,6 km/h, >17,6-21,5 km/h, >21,5 km/h. Os resultados mostram entre períodos de alta velocidade e sprints, velocidade máxima, desacelerações e acelerações totais. Em conclusão, a categorização das demandas com base no desvio padrão de acordo com a velocidade máxima poderia ser uma opção viável para individualizar a análise da distância percorrida pelas velocidades em esportes coletivos como o basquetebol. Seu uso pode ajudar a compreender e contextualizar melhor os dados de movimento em esportes e equipes específicas.


Assuntos
Humanos , Basquetebol/educação , Treinamento Intervalado de Alta Intensidade/classificação
2.
Arch Bronconeumol (Engl Ed) ; 57(3): 186-194, 2021 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32253119

RESUMO

INTRODUCTION: Primary ciliary dyskinesia (PCD) is characterized by an alteration in the ciliary structure causing difficulty in the clearance of respiratory secretions. Diagnosis is complex and based on a combination of techniques. The objective of this study was to design a gene panel including all known causative genes, and to corroborate their diagnostic utility in a cohort of Spanish patients. METHODS: This was a multicenter cross-sectional study of patients with a high suspicion of PCD, according to European Respiratory Society criteria, designed around a gene panel for massive sequencing using SeqCap EZ capture technology that included 44 genes associated with PCD. RESULTS: We included 79 patients, 53 of whom had a diagnosis of confirmed or highly probable PCD. The sensitivity of the gene panel was 81.1%, with a specificity of 100%. Candidate variants were found in some of the genes of the panel in 43 patients with PCD, 51.2% (22/43) of whom were homozygotes and 48.8% (21/43) compound heterozygotes. The most common causative genes were DNAH5 and CCDC39. We found 52 different variants, 36 of which were not previously described in the literature. CONCLUSIONS: The design and implementation of a tailored gene panel produces a high yield in the genetic diagnosis of PCD. This panel provides a better understanding of the causative factors involved in these patients and lays down the groundwork for future therapeutic approaches.


Assuntos
Síndrome de Kartagener , Estudos Transversais , Homozigoto , Humanos , Síndrome de Kartagener/diagnóstico , Mutação
3.
J. oral res. (Impresa) ; 8(4): 325-330, nov. 5, 2019. graf
Artigo em Inglês | LILACS | ID: biblio-1145355

RESUMO

The aim of the study was to quantify and compare apical debris extrusion in two systems of continuous and reciprocating rotary instrumentation with, and without, the use of a patency file. An experimental study was carried out in 120 mesial roots of lower first molars, which were randomized in the following 4 groups: Group A. Reciproc (VDW) R25 without a patency file, Group B Mtwo (VDW) without a patency file, Group C Reciproc (VDW) R25 with a patency file and Group D Mtwo with a patency file. Groups A, B and C presented statistically significant differences in comparison to group D, Mtwo with the use of a patency file (p<0.008 to 95% reliability). In conclusion, the greater amount of debris extruded through the apex occurred in roots instrumented with the reciprocating rotary system; this difference was statistically significant in relation to teeth treated with the Mtwo continuous rotary system with the use of a patency file.


El objetivo del estudio fue cuantificar y comparar la extrusión de residuos apicales en dos sistemas de instrumentación endodónticos rotativos, continuo y recíproco, con y sin el uso de una lima de pasaje apical. Se realizó un estudio experimental en 120 raíces mesiales de primeros molares inferiores, que se aleatorizaron en los siguientes 4 grupos: Grupo A. Reciproc (VDW) R25 sin lima de pasaje apical, Grupo B Mtwo (VDW) sin lima de pasaje apical, Grupo C Reciproc (VDW) R25 con lima de pasaje apical y Grupo D Mtwo con lima de pasaje apical. Los grupos A, B y C presentaron diferencias estadísticamente significativas encomparación con el grupo D, Mtwo con el uso de una lima de pasaje apical (p<0.008 a 95% de confiabilidad). En conclusión, la mayor cantidad de residuos extruidos a través del ápice ocurrió en raíces preparadas con el sistema rotativo recíproco; Esta diferencia fue estadísticamente significativa en relación a los dientes tratados con el sistema rotativo continuo Mtwo con el uso de una lima de pasaje apical.


Assuntos
Humanos , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Ápice Dentário , Instrumentos Odontológicos , Cavidade Pulpar
4.
Lima; Instituto Nacional de Salud; oct. 2019.
Não convencional em Espanhol | BRISA/RedTESA | ID: biblio-1129783

RESUMO

INTRODUCCIÓN: Este documento técnico se realiza a solicitud del Instituto Nacional de Salud del Niño - San Borja. A. Cuadro clínico: La craneotomía es un procedimiento neuroquirúrgico con el objetivo de lograr una amplia abertura craneal con el propósito final de realizar una maniobra terapéutica quirúrgica dentro del espacio intracraneal. La craneotomía generalmente se realiza bajo anestesia general, pero también se puede hacer con el paciente despierto usando un anestésico local. La cantidad de cráneo que debe extraerse depende del tipo de cirugía que se realice. El colgajo óseo se extrae principalmente con la ayuda de un taladro craneal y un craneótomo. B. Tecnología sanitaria: El craneótomo de alta velocidad es un dispositivo que se utiliza para realizar una craneotomía, trazando líneas de fresado entre los agujeros de craneotomía con el fin de elevar el colgajo óseo. La velocidad de corte y las revoluciones por minuto de un equipo estándar es de 6.53 m/min y de 10000 rpm aproximadamente, mientras que el craneótomo de alta velocidad puede llegar a 140 m/min y 40000rpm respectivamente. Se postula que esta propiedad disminuiría el tiempo operatorio, entre otras ventajas. OBJETIVO: Evaluar la eficacia y seguridad, así como documentos relacionados a la decisión de cobertura de craneótomo de alta velocidad para craneotomías. METODOLOGÍA: Se realizó una búsqueda en las principales bases de datos bibliográficas: MEDLINE, LILACS, COCHRANE, así como en buscadores genéricos de Internet incluyendo Google Scholar y TRIPDATABASE. Adicionalmente, se hizo una búsqueda dentro de la información generada por las principales instituciones internacionales de ginecología y agencias de tecnologías sanitarias que realizan revisiones sistemáticas (RS), evaluación de tecnologías sanitarias (ETS) y guías de práctica clínica (GPC). RESULTADOS: No se identificaron ensayos clínicos aleatorizados, revisiones sistemáticas o estudios observacionales que proporcionaran datos comparativos de la tecnología de interés versus el comparador. Además, no se encontraron guías de práctica clínica, evaluaciones de tecnología sanitaria ni revisiones sistemáticas. Se identificaron tres estudios observacionales que describen la experiencia del uso de la tecnología. CONCLUSIONES: La evidencia con respecto al uso del craneótomo de alta velocidad para craneotomía es escasa. Si bien no se identificó estudios comparativos del uso de esta tecnología, existen reportes de casos que evidencian el alto uso del dispositivo, la seguridad de éste sin presentar eventos adversos y la disminución en la duración del tiempo operatorio para el procedimiento de craneotomía. No se identificaron guías de práctica clínica, evaluaciones de tecnología sanitaria ni evaluaciones económicas que evalúen a la tecnología de interés.


Assuntos
Humanos , Craniotomia/instrumentação , Equipamentos e Provisões/provisão & distribuição , Peru , Avaliação da Tecnologia Biomédica , Análise Custo-Benefício
5.
Rev. ADM ; 76(5): 261-266, sept.-oct. 2019. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1052989

RESUMO

Los profesionales de la salud están expuestos a una gran variedad de microorganismos desde esporas, bacterias, hongos, virus y protozoarios que pueden encontrarse en la sangre y/o saliva de los pacientes. Cualquiera de estos microorganismos puede causar una enfermedad infectocontagiosa a través de pinchazos y/o salpicaduras producidas por el aerosol durante la práctica dental. Objetivo: Determinar la presencia bacteriana en las piezas de alta velocidad utilizadas en la práctica clínica. Material y métodos: Es un estudio experimental, observacional y transversal en el que se evaluó la contaminación de 30 piezas de alta velocidad utilizadas en la práctica clínica. Previo al estudio se efectuó una estandarización obteniendo una kappa del 0.85. Se realizó una base de datos en el programa SPSS versión 22, con el que se llevó a cabo el análisis descriptivo para determinar medidas de tendencia central. Resultados: 73.3% de las muestras analizadas tuvieron crecimiento bacteriano, entre las bacterias que se encontraron resultó que 54.5% de ellas fueron bacterias Gram positivas y el resto Gram negativas. La bacteria con mayor presencia en la muestra fue el Bacillus en 45.5% seguida del Streptococcus en 27.3%, el restante 27.2% fue Staphylococcus, Coccus y Streptobacillus. Conclusiones: El uso correcto de las piezas de alta, así como su desinfección en la consulta dental es de suma importancia, ya que nos ayudan a evitar contaminaciones cruzadas y a prevenir que dentro del área de trabajo se formen focos de infección (AU)


Health professionals are exposed to a wide variety of microorganisms from spores, bacteria, fungi, viruses and protozoa that can be found in the blood and/or saliva of patients. Any of these microorganisms can cause an infectious disease through punctures and / or splashes produced by the aerosol during dental practice.1,2 Objective: To determine the bacterial presence in the high-speed pieces used in clinical practice. Material and methods: It are an experimental, observational and transversal study; where the contamination of 30 high-speed pieces used in clinical practice was evaluated. Prior to the study, a standardization was made obtaining a kappa of 0.85. A database was made in the program SPSS version 22, with which the descriptive analysis was carried out to determine measures of central tendency. Results: 73.3% of the analyzed samples showed bacterial growth, among the bacteria that were found, 54.5% of them were gram-positive bacteria and the rest were gram-negative. The bacterium with the highest presence in the sample was for Bacillus in 45.5% followed by Streptococcus in 27.3%, the remaining 27.2% was for Staphylococcus, Coccus and Streptobacillus. Conclusions: The correct use of the discharging parts, as well as their disinfection in the dental practice is of the utmost importance as they help us to avoid cross contamination and to prevent foci of infection from forming within the work area (AU)


Assuntos
Equipamentos Odontológicos de Alta Rotação/microbiologia , Contaminação Biológica , Controle de Infecções Dentárias/métodos , Contagem de Colônia Microbiana , Estudos Transversais , Meios de Cultura , Clínicas Odontológicas/normas , Estudo Observacional
6.
J Optom ; 12(2): 84-91, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30037645

RESUMO

PURPOSE: To evaluate the temperature rise of human cornea during trans-epithelial photorefractive keratectomy (trans-PRK) with a 750Hz excimer laser employing Intelligent Thermal Effect Control (ITEC) software. METHODS: In this observational case series, trans-PRK ablation was performed on 5 eyes of 3 patients using an aspheric profile of a 750Hz excimer laser system. A high-resolution infrared camera with a frame-rate of 350 images per second was used to determine the corneal surface temperature. Images were taken sequentially, starting a few seconds prior to and ending a few seconds after the ablation. The maximum temperature of any pixel of a given image were recorded and graphed against time. RESULTS: The baseline ocular surface temperature, immediately prior to the beginning of excimer laser, ranged from 32 to 34.9°C. The maximum ocular surface temperature until the epithelium was ablated ranged from 35.2 to 39.7°C. The maximum ocular surface temperature during stromal ablation with high and low fluence laser ranged from 32.9 to 36.5 and from 34.4 to 37.7°C respectively. CONCLUSION: The ITEC software is effective in controlling the maximum temperature rise during laser ablation in the extremely challenging situation of trans-PRK involving high ablation volumes of almost 6000nl, potentially improving the outcomes. The ITEC system limited the maximum temperature to 39.7°C in the epithelium, and 37.7°C in the stroma. The epithelial temperature was always higher than stromal temperature (regardless of high or low fluence irradiation). Safety limit of 40°C found in the literature was never reached.


Assuntos
Temperatura Corporal/fisiologia , Córnea/fisiologia , Terapia a Laser/métodos , Lasers de Excimer/uso terapêutico , Miopia/terapia , Ceratectomia Fotorrefrativa/métodos , Termografia/métodos , Adulto , Feminino , Humanos , Terapia a Laser/efeitos adversos , Lasers de Excimer/efeitos adversos , Masculino , Pessoa de Meia-Idade
7.
Rev. ADM ; 75(2): 92-97, mar.-abr. 2018. ilus
Artigo em Espanhol | LILACS | ID: biblio-907051

RESUMO

Introducción: La cirugía de los terceros molares es el procedimiento quirúrgico más frecuentemente realizado por los cirujanos orales y maxilofaciales, que a pesar de contar con una vasta experiencia y entrenamiento en el área quirúrgica pueden presentarse complicaciones transoperatorias y postoperatorias. Cuando éste es realizado por un cirujano dentista de práctica general las complicaciones pueden aumentar. Presentación de caso clínico: Se trata de un paciente de 25 años de edad sometido a extracción quirúrgica de terceros molares por un dentista de práctica general, el cual realiza procedimiento quirúrgico con uso de pieza de mano de alta velocidad. Tres días posteriores al evento quirúrgico el paciente acude al Departamento de Cirugía Oral y Maxilofacial del Instituto de Seguridad y Servicios Sociales de los Trabajadores del Estado por presentar edema, infl amación y crepitación en región bucal, maseterina y submandibular derecha, así como limitación a la apertura bucal de 25 mm. En tomografía computarizada contrastada se obs erva desviación de la vía aérea hacia el lado izquierdo. Se decide manejó del proceso infeccioso y de enfi sema subcutáneo con farmacoterapia y drenaje del mismo. Una vez remitido el enfi sema subcutáneo, en la cuarta semana de evolución el paciente refi ere limitación a la abducción del hombro derecho, observándose atrofi a del músculo trapecio y esternocleidomastoideo ipsilateral, correspondiente a lesión del XI par craneal. Discusión: La lesión del nervio accesorio (XI par craneal) ocasiona parálisis del músculo trapecio, principal estabilizador de la escápula que contribuye en los movimientos de fl exión, rotación y abducción del hombro. El trayecto del XI par craneal es superfi cial en el triángulo posterior del cuello presentando susceptibilidad a ser lesionado de manera iatrogénica, en este caso la utilización de pieza de mano de alta velocidad durante la extracción quirúrgica de los terceros molares generó enfi sema subcutáneo que condicionó la posible compresión del nervio accesorio, lesionando al mismo (AU)


Introduction: The third molar surgery is the most frequent surgical procedure performed by oral and maxillofacial surgeons, who despite their vast experience and training in the surgical area can present transoperatory and postoperative complications. When the oral surgery is done by a general practice dentist the complications can be increased. Case presentation: A 25-year-old male patient undergoing third molar surgery by a general practice dentist who performs a surgical procedure using a high-speed handpiece. Three days after the surgical procedure patient comes to the Department of Oral and Maxillofacial Surgery Institute for Social Security and Services for State Workers by present edema, swelling and crepitus in buccal space, masseteric and right submandibular region and limitation of mouth opening of 25 mm. Contrast computed tomography shows airway deviation to the left side. We decided to manage the infectious process and subcutaneous emphysema with antibiotic therapy and drainage. After subcutaneous emphysema was in remission, in the fourth week of evolution, the patient reported limitation of abduction of the right shoulder, with atrophy of the trapezius muscle and ipsilateral sternocleidomastoid, corresponding to a lesion of the XI cranial nerve. Discussion: Accessory nerve injury (XI cranial nerve) causes palsy of the trapezius muscle, the major stabilizer of the scapula that contributes to the fl exion, rotation and abduction movements of the shoulder. The trajectory of the XI cranial nerve is superfi cial in the posterior triangle of the neck presenting susceptibility to iatrogenic injury, in this case, the use of high-speed handpiece during the surgical extraction of the third molars, caused subcutaneous emphysema that conditioned the possible compression of the spinal nerve (AU)


Assuntos
Humanos , Feminino , Adulto , Nervo Acessório , Equipamentos Odontológicos de Alta Rotação , Dente Serotino , Paralisia , Enfisema Subcutâneo , Extração Dentária , Unidade Hospitalar de Odontologia , Infecção Focal Dentária , Complicações Intraoperatórias , México
8.
Rev. ADM ; 74(4): 185-188, jul.-ago. 2017. ilus, graf
Artigo em Espanhol | LILACS | ID: biblio-908020

RESUMO

Introducción: en los procedimientos odontológicos se está expuestoa gran cantidad de microorganismos y las intervenciones clínicas provocan un contacto directo o indirecto con éstos, ya sea a través del instrumental, equipo odontológico contaminado con saliva, sangre, exudados, etcétera. Por esta razón debe tomarse en cuenta el tipo de contaminación de las piezas de mano por ser parte del equipo de uso cotidiano para realizar tratamientos odontológicos. Objetivos generales:Determinar la carga bacteriana en las piezas de alta velocidad antes y después de su uso en diferentes clínicas de la Facultad de Odontologíade la UV Región Veracruz. Metodología: Investigación transversal, descriptiva y observacional. Material y métodos: Se seleccionaron al azar 30 piezas de mano de los estudiantes de la Universidad Veracruzana Facultad de Odontología Región Veracruz, a las cuales se tomó una muestra con un hisopo de algodón antes y después de su uso en la práctica dental. Se realizaron cultivos con las muestras obtenidas que se observaron durante tres días seguidos bajo microscopio para comprobar la presencia de colonias bacterianas. Resultados: De las30 piezas antes de ser utilizadas se detectó Bacillus grampositivos en24 por ciento de las muestras; en 20 por ciento Bacillus gramnegativos, en 6 por ciento Streptobacillus gram-positivos; en 20 por ciento Staphylococcus grampositivos; en 3 por ciento Cocobacillus gramnegativos y en 22 por ciento Actinomyces gramnegativos. El restante 2 por ciento no reveló unidades formadoras de colonias (UFC). En un segundo muestreo, 33 por ciento desarrolló Bacillus grampositivos, 10 por cientoBacillus gramnegativos, 20 por ciento adquirió Sthapylococcus grampositivos, 3 por ciento Sthapylococcus gramnegativo y 34 por ciento no reveló UFC. Conclusión:En el primer muestreo se detectaron microorganismos en 98% de laspiezas de mano, mientras que en el segundo muestreo 66% se contaminócon microorganismos y en 34% no se observó contaminación.


Introduction: dental activity is exposed to a lot of microorganisms,and clinical interventions have a direct or indirect contact with them.Whether through the instruments, dental equipment contaminatedwith saliva, blood, etc; so you should take into account the type ofcontamination of handpieces for being the most widely used equipmentfor dental treatment. General Objectives: Determine the bacterialload in high-speed parts before and after being used in diff erentclinical uses in Dentistry School at UV, Veracruz. Methodology:Cross-sectional, descriptive and observational research. Materialand methods: 30 pieces of students from the Universidad VeracruzanaSchool of Dentistry, Veracruz region, which a sample was takenwith a swab to pieces before and after use in dental practice wererandomly selected. Cultures with samples obtained observedduring three days in a row microscope to determine the presenceof bacterial colonies were made. Results: Of the 30 pieces beforebeing used 24% of Bacillus Gram-positive samples were found; 20%Bacillus Gram-negative, Gram-positive Streptobacillus 6%; 20%Gram-positive Staphylococcus, 3% developed Coccobacillus Gramnegativeand 22% Gram negative Actinomyces. The remaining 2%no colony forming units development (UFC). In a second sampling;33% developed Bacillus Gram-positive, Gram-negative Bacillus10%, 20% obtained Sthapylococcus Gram-positive, Gram-negativeSthapylococcus 3% and 34% did not develop colony forming unit(CFU). Conclusion: In the first sampling 98% of the pieces were microorganism growth, while in the second 66% and the presence ofmicroorganisms obtained 34% no development.


Assuntos
Humanos , Equipamentos Odontológicos de Alta Rotação/microbiologia , Equipamentos Odontológicos de Alta Rotação/normas , Controle de Infecções Dentárias/métodos , Tratamento do Canal Radicular/instrumentação , Faculdades de Odontologia , Estudos Transversais , Meios de Cultura , Contagem de Colônia Microbiana/métodos , Epidemiologia Descritiva , Contaminação de Equipamentos/prevenção & controle , Bacilos e Cocos Aeróbios Gram-Negativos/isolamento & purificação , Bacilos Gram-Positivos/isolamento & purificação , México
9.
Univ. odontol ; 36(77)2017. ilus, tab
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-996481

RESUMO

Antecedentes: Los hallazgos reportados en la literatura no relacionan directamente la efectividad de corte de las fresas de diamante de alta velocidad con la cantidad y calidad de diamantes en la superficie, ni su vida media después de un determinado número de usos. Objetivo: Evaluar la durabilidad de los diamantes de corte de la superficie activa de las fresas después de realizar desgastes en dientes naturales. Métodos: Este estudio ex vivo comparó 4 marcas comerciales de fresas de diamante con granos de 64-126 |zm, de forma troncocónica y punta redonda (norma ISO 850): MDT", Swisstech*, Pointech* y Jota". Se realizaron 5 cortes de 0,16 mm con cada fresa en la corona del diente. Luego se analizaron las fresas en microscopio electrónico de barrido para observar: a) adhesión de diamantes al sustrato en cabeza y cuerpo; b) estado de los diamantes en el sustrato en cabeza y cuerpo, tras los 5 cortes; y c) estadofinal de las fresas. Se realizó un análisis cualitativo y cuantitativo. Resultados: Todas las fresas de las 4 marcas presentaron similar desgaste después de los 5 usos, tanto en la cabeza como el cuerpo. Pese a que todas las muestras presentaban variaciones, en algunas fue más evidente el desalojo y fractura de los diamantes. Conclusión: El estudio sugiere que las fresas deberían cambiarse después de 5 usos clínicos para garantizar un desgaste adecuado y evitar daños pulpares ocasionados por la fricción.


Background: Outcomes reported in the literature do not relate cutting effectiveness of high-speed diamond drills directly to the diamond surface amount and quality, not either their average life after a specific number of uses. Objective: To evaluate the durability of diamond burrs in the drill active surface after doing removal in natural teeth. Methods: This ex vivo study compared dental drills of four different brand names with 64-126 pm, round tip, conical-trunk diamond grit (ISO 850): MDT", Swisstech", Pointech* and Jota". Five 0.16 mm cuts were carried out using each dental drill on a tooth crown. The dental drills were then analyzed under the scanning electron microscope in order to observe: a) any adhesion of diamond to substrate in the head and body; b) condition of the diamonds in the substrate, in head and body, after 5 cuts; and c) final condition of the dental drills. Then a qualitative and quantitative analysis was carried out. ResuJts: The four different dental drills showed a similar worn condition after five uses, both in the head and body. Despite all the samples showed variations, some of them had greater evidence of diamond fracture and displacement. Conclusion: This study suggests that the dental drills should be changed over after 5 clinical uses in order to ensure a desirable worn condition and prevent pulpal damage due to the friction.


Assuntos
Microscopia Eletrônica de Varredura , Preparo da Cavidade Dentária , Instrumentos Odontológicos/classificação , Instrumentos Odontológicos/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA