Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(12)2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38931744

RESUMO

This research proposes a miniature circular polarization antenna used in a wireless capsule endoscopy system at 2.45 GHz for industrial, scientific, and medical bands. We propose a method of cutting a chamfer rectangular slot on a circular radiation patch and introducing a curved radiation structure into the centerline position of the chamfer rectangular slot, while a short-circuit probe is added to achieve miniaturization. Therefore, we significantly reduced the size of the antenna and made it exhibit circularly polarized radiation characteristics. A cross-slot is cut in the GND to enable the antenna to better cover the operating band while being able to meet the complex human environment. The effective axis ratio bandwidth is 120 MHz (2.38-2.50 GHz). Its size is π × 0.032λ02 × 0.007λ0 (where λ0 is the free-space wavelength of at 2.4 GHz). In addition, the effect of different organs such as muscle, stomach, small intestine, and big intestine on the antenna when it was embedded into the wireless capsule endoscopy (WCE) system was further discussed, and the results proved that the WCE system has better robustness in different organs. The antenna's specific absorption rate can follow the IEEE Standard Safety Guidelines (IEEE C95.1-1999). A prototype is fabricated and measured. The experimental results are consistent with the simulation results.


Assuntos
Endoscopia por Cápsula , Desenho de Equipamento , Tecnologia sem Fio , Endoscopia por Cápsula/instrumentação , Endoscopia por Cápsula/métodos , Humanos , Tecnologia sem Fio/instrumentação , Cápsulas Endoscópicas
2.
Sensors (Basel) ; 24(5)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38475232

RESUMO

Aseptic loosening is the dominant failure mechanism in contemporary knee replacement surgery, but diagnostic techniques are poorly sensitive to the early stages of loosening and poorly specific in delineating aseptic cases from infections. Smart implants have been proposed as a solution, but incorporating components for sensing, powering, processing, and communication increases device cost, size, and risk; hence, minimising onboard instrumentation is desirable. In this study, two wireless, battery-free smart implants were developed that used passive biotelemetry to measure fixation at the implant-cement interface of the tibial components. The sensing system comprised of a piezoelectric transducer and coil, with the transducer affixed to the superior surface of the tibial trays of both partial (PKR) and total knee replacement (TKR) systems. Fixation was measured via pulse-echo responses elicited via a three-coil inductive link. The instrumented systems could detect loss of fixation when the implants were partially debonded (+7.1% PKA, +32.6% TKA, both p < 0.001) and fully debonded in situ (+6.3% PKA, +32.5% TKA, both p < 0.001). Measurements were robust to variations in positioning of the external reader, soft tissue, and the femoral component. With low cost and small form factor, the smart implant concept could be adopted for clinical use, particularly for generating an understanding of uncertain aseptic loosening mechanisms.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Falha de Prótese , Reoperação/métodos , Tíbia/cirurgia , Articulação do Joelho/cirurgia , Desenho de Prótese
3.
IEEE Trans Antennas Propag ; 70(11): 10132-10140, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36407055

RESUMO

We present a biocompatible high-contrast low-loss antenna (HCLA) designed for efficient into-body radiation for applications as diverse as medical telemetry, sensing, and imaging. The HCLA is wearable with a compact size of 2.62 cm3 and operates across the 1 to 5 GHz bandwidth. The quasi-bowtie antenna is loaded with a high-contrast (i.e., alternating layers of high and low permittivity materials) and low-loss dielectric to improve directivity and gain into the biological tissues. Measurement results at 2.4 GHz are in good agreement with simulations and show 5.72 dB improvement in transmission loss over the most efficient into-body radiator reported in the past. At the high end of the frequency bandwidth, simulation results for two antennas placed across each other with tissue in between show ~12.5 dB improvement in transmission loss. The HCLA is fabricated with stable, low-loss materials that allow for repeatability and consistency in the fabrication process, thus, addressing limitations of the current state-of-the-art. It is also made from biocompatible materials that enable it to be placed directly on the skin for real-world implementation. In this paper, we discuss the operation principle and design of the HCLA, its transmission performance, radiation patterns, and specific absorption rate.

4.
Biosens Bioelectron ; 213: 114455, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35738215

RESUMO

Electrical activity recordings are critical for evaluating and understanding brain function. We present a novel wireless, implantable, and battery-free device, namely the Wireless Neurosensing System (WiNS), and for the first time, we evaluate multichannel recording capabilities in vivo. For a preliminary evaluation, we performed a benchtop experiment with emulated sinusoidal signals of varying amplitude and frequency, representative of neuronal activity. We later performed and analyzed electrocortical recordings in rats of evoked somatosensory activity in response to three paradigms: hind/fore limb and whisker stimulation. Wired recordings were used for comparison and validation of WiNS. We found that through the channel multiplexing element of WiNS, it is possible to perform multichannel recordings with a maximum sampling rate of ∼10 kHz for a total of eight channels. This sampling rate is appropriate for monitoring the full range of neuronal signals of interest, from low-frequency population recordings of electrocorticography and local field potentials to high-frequency individual neuronal spike recordings. These in vivo experiments demonstrated that the evoked neuronal activity recorded with WiNS is comparable to that recorded with a wired system under identical circumstances. Analysis of critical parameters for interpreting the somatosensory evoked activity showed no statistically significant difference between the parameters obtained by a wired system versus those obtained using WiNS. Therefore, WiNS can match the performance of more invasive recording systems. WiNS is a groundbreaking technology with potential applications throughout neuroscience as it offers a simple alternative to address the pitfalls of battery-powered neuronal implants.


Assuntos
Técnicas Biossensoriais , Tecnologia sem Fio , Animais , Eletrocorticografia , Desenho de Equipamento , Neurônios , Ratos
5.
Bioelectromagnetics ; 42(7): 583-592, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34424566

RESUMO

A major challenge in developing robust wireless links to implanted/ingestible antennas is the potential for rotational misalignment. In this paper, we present an artificially anisotropic quarter-wave plate (QWP) capable of developing a circularly polarized wave from a linearly polarized wave. Without loss of generality, our QWP is composed of plastic and hydrogel, while the linearly polarized wave is developed by a bio-matched antenna-a high gain, broadband antenna with a dielectric engineered to match to biological tissues. Using a basic implanted patch antenna, we demonstrate a 1.00 dB (1.26) variance in transmission coefficient over a 90° variance, with a remarkable average measured transmission coefficient of -34.4 dB (3.63 × 10-4 ) at 2.4 GHz. Without the QWP, the rotational variance is 12.52 dB (17.9). Notably, the QWP increases the maximum input power to comply with specific absorption rate limitations. In our case, this allows for -15.0 dBm (31.6 µW) of power to be received by the implant, which is comparable to the -15.7 dBm (26.9 µW) received without the QWP. Additionally, we demonstrate that with the QWP, the standard deviation from the mean transmission for rotational misalignments remains below 3 dB (2.00) from 2 to 3.62 GHz, resulting in a simulated 57.7% fractional bandwidth. © 2021 Bioelectromagnetics Society.


Assuntos
Próteses e Implantes , Telemetria , Desenho de Equipamento
6.
Sensors (Basel) ; 20(24)2020 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-33371238

RESUMO

Photoplethysmography is an extensively-used, portable, and noninvasive technique for measuring vital parameters such as heart rate, respiration rate, and blood pressure. The deployment of this technology in veterinary medicine has been hindered by the challenges in effective transmission of light presented by the thick layer of skin and fur of the animal. We propose an injectable capsule system to circumvent these limitations by accessing the subcutaneous tissue to enable reliable signal acquisition even with lower light brightness. In addition to the reduction of power usage, the injection of the capsule offers a less invasive alternative to surgical implantation. Our current prototype combines two application-specific integrated circuits (ASICs) with a microcontroller and interfaces with a commercial light emitting diode (LED) and photodetector pair. These ASICs implement a signal-conditioning analog front end circuit and a frequency-shift keying (FSK) transmitter respectively. The small footprint of the ASICs is the key in the integration of the complete system inside a 40-mm long glass tube with an inner diameter of 4 mm, which enables its injection using a custom syringe similar to the ones used with microchip implants for animal identification. The recorded data is transferred wirelessly to a computer for post-processing by means of the integrated FSK transmitter and a software-defined radio. Our optimized LED duty cycle of 0.4% at a sampling rate of 200 Hz minimizes the contribution of the LED driver (only 0.8 mW including the front-end circuitry) to the total power consumption of the system. This will allow longer recording periods between the charging cycles of the batteries, which is critical given the very limited space inside the capsule. In this work, we demonstrate the wireless operation of the injectable system with a human subject holding the sensor between the fingers and the in vivo functionality of the subcutaneous sensing on a pilot study performed on anesthetized rat subjects.


Assuntos
Fotopletismografia/instrumentação , Fotopletismografia/veterinária , Próteses e Implantes , Processamento de Sinais Assistido por Computador , Tecnologia sem Fio , Animais , Desenho de Equipamento , Projetos Piloto , Ratos , Telemetria
7.
Healthc Technol Lett ; 6(5): 147-152, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31839971

RESUMO

Venous leg ulcerations are a common problem, with high prevalence in the middle-aged and elderly population, and more attention on research of their physical activities has been paid, as they have great effects on the blood circulation of the lower limb. With enough, appropriate training, the chronic venous ulcerations in the lower limb can be avoided and alleviated, and venous hypertension can be reduced effectively. The study deals with a physical activity tracking system for the patients based on a three-axis accelerometer. The system uses a three-axis accelerometer, a microcontroller, and a wireless Bluetooth module to form a data acquisition platform to acquire accelerations of the lower limb movement, and sends it to a smart mobile phone via the wireless Bluetooth module. The system takes advantages of the smart mobile phone to guide the chronic venous leg ulcers to do prescribed rehabilitation exercises for the lower limb muscles, perform acceleration data preprocessing, wavelet transform and reconstruction, denoising and feature extraction, obtain the results of the rehabilitation exercises, and then give reasonable evaluation and judgment. It is helpful to treat underlying venous reflux, create such an environment that allows skin to grow across an ulcer, and accelerate ulcer healing process consequently.

8.
Healthc Technol Lett ; 5(4): 113-117, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30155262

RESUMO

A wireless body-centric nano-network consists of various nano-sized sensors with the purpose of healthcare application. One of the main challenges in the network is caused by the very limited power that can be stored in nano-batteries in comparison with the power required to drive the device for communications. Recently, novel rectifying antennas (rectennas) based on carbon nanotubes (CNTs), metal and graphene have been proposed. At the same time, research on simultaneous wireless information and power transfer (SWIPT) schemes has progressed apace. Body-centric nano-networks can overcome their energy bottleneck using these mechanisms. In this Letter, a nano-rectenna energy harvesting model is developed. The energy harvesting is realised by a nano-antenna and an ultra-high-speed rectifying diode combined as a nano-rectenna. This device can be used to power nanosensors using part of the terahertz (THz) information signal without any other system external energy source. The broadband properties of nano-rectennas enable them to generate direct current (DC) electricity from inputs with THz to optical frequencies. The authors calculate the output power generated by the nano-rectenna and compare this with the power required for nanosensors to communicate in the THz band. The calculation and analysis suggest that the nano-rectenna can be a viable approach to provide power for nanosensors in body-centric nano-networks.

9.
Sensors (Basel) ; 17(8)2017 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-28767090

RESUMO

When using the conventional two-coil inductive link for the simultaneous wireless power and data transmissions in implantable biomedical sensor devices, the strong power carrier could overwhelm the uplink data signal and even saturate the external uplink receiver. To address this problem, we propose a new magnetic-balanced inductive link for our implantable glaucoma treatment device. In this inductive link, an extra coil is specially added for the uplink receiving. The strong power carrier interference is minimized to approach zero by balanced canceling of the magnetic field of the external power coil. The implant coil is shared by the wireless power harvesting and the uplink data transmitting. Two carriers (i.e., 2-MHz power carrier and 500-kHz uplink carrier) are used for the wireless power transmission and the uplink data transmission separately. In the experiments, the prototype of this link achieves as high as 65.72 dB improvement of the signal-to-interference ratio (SIR) compared with the conventional two-coil inductive link. Benefiting from the significant improvement of SIR, the implant transmitter costs only 0.2 mW of power carrying 50 kbps of binary phase shift keying data and gets a bit error rate of 1 × 10 - 7 , even though the coupling coefficient is as low as 0.005. At the same time, 5 mW is delivered to the load with maximum power transfer efficiency of 58.8%. This magnetic-balanced inductive link is useful for small-sized biomedical sensor devices, which require transmitting data and power simultaneously under ultra-weak coupling.

10.
Sensors (Basel) ; 17(6)2017 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-28604610

RESUMO

The inductive link is widely used in implantable biomedical sensor systems to achieve near-field communication (NFC) and wireless power transfer (WPT). However, it is tough to achieve reliable NFC on an inductive WPT link when the coupling coefficient is ultra-low (0.01 typically), since the NFC signal (especially for the uplink from the in-body part to the out-body part) could be too weak to be detected. Traditional load shift keying (LSK) requires strong coupling to pass the load modulation information to the power source. Instead of using LSK, we propose a dual-carrier NFC scheme for the weak-coupled inductive link; using binary phase shift keying (BPSK) modulation, its downlink data are modulated on the power carrier (2 MHz), while its uplink data are modulated on another carrier (125 kHz). The two carriers are transferred through the same coil pair. To overcome the strong interference of the power carrier, dedicated circuits are introduced. In addition, to minimize the power transfer efficiency decrease caused by adding NFC, we optimize the inductive link circuit parameters and approach the receiver sensitivity limit. In the prototype experiments, even though the coupling coefficient is as low as 0.008, the in-body transmitter costs only 0.61 mW power carrying 10 kbps of data, and achieves a 1 × 10 - 7 bit error rate under the strong interference of WPT. This dual-carrier NFC scheme could be useful for small-sized implantable biomedical sensor applications.


Assuntos
Próteses e Implantes , Amplificadores Eletrônicos , Fontes de Energia Elétrica , Desenho de Equipamento , Telemetria , Tecnologia sem Fio
11.
Biomed Microdevices ; 18(5): 75, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27492638

RESUMO

We present in-vivo study related to the use of our implantable RF telemetry system for pressure-volume (PV) cardiac monitoring in a animal subject. We implant a commercial MEMS PV sensor into the subject's heart left-ventricle (LV), while the telemetry system is implanted outside of the heart and connected to the sensor with a 7-microwires tether. The RF telemetry system is suitable for commercial application in medium sized subjects, its total volume of 2.475cm(3) and a weight of 4.0g. Our designed system is 58 % smaller in volume, 44 % in weight and has a 55 % reduction in sampling power over the last reported research in PV telemetry. In-vivo data was captured in both an acute and a freely moving setting over a 24 hour period. We experimentally demonstrated viability of the methodology that includes the surgical procedure and real-time monitoring of the in-vivo data in a freely moving subject. Further improvements in catheter design will improve the data quality and safety of the subject. This real-time implantable technology allows for researchers to quantify cardiac pathologies by extracting real-time pressure-volume loops, wirelessly from within freely moving subjects.


Assuntos
Ventrículos do Coração , Pressão , Telemetria/instrumentação , Animais , Calibragem , Movimento , Imagens de Fantasmas , Próteses e Implantes , Suínos , Fatores de Tempo , Tecnologia sem Fio
12.
Healthc Technol Lett ; 3(2): 124-8, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27382481

RESUMO

Analysis of thoracic electrical bio-impedance (TEB) facilitates heart stroke volume in sudden cardiac arrest. This Letter proposes several efficient and computationally simplified adaptive algorithms to display high-resolution TEB component. In a clinical environment, TEB signal encounters with various physiological and non-physiological phenomenon, which masks the tiny features that are important in identifying the intensity of the stroke. Moreover, computational complexity is an important parameter in a modern wearable healthcare monitoring tool. Hence, in this Letter, the authors propose a new signal conditioning technique for TEB enhancement in remote healthcare systems. For this, the authors have chosen higher order adaptive filter as a basic element in the process of TEB. To improve filtering capability, convergence speed, to reduce computational complexity of the signal conditioning technique, the authors apply data normalisation and clipping the data regressor. The proposed implementations are tested on real TEB signals. Finally, simulation results confirm that proposed regressor clipped normalised higher order filter is suitable for a practical healthcare system.

14.
Healthc Technol Lett ; 2(1): 22-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26609400

RESUMO

The use of wearable biomedical sensors for the continuous monitoring of physiological signals will facilitate the involvement of the patients in the prevention and management of chronic diseases. The fabrication of small biomedical sensors transmitting physiological data wirelessly is possible as a result of the tremendous advances in ultra-low power electronics and radio communications. However, the widespread adoption of these devices depends very much on their ability to operate for long periods of time without the need to frequently change, recharge or even use batteries. In this context, energy harvesting (EH) is the disruptive technology that can pave the road towards the massive utilisation of wireless wearable sensors for patient self-monitoring and daily healthcare. Radio-frequency (RF) transmissions from commercial telecommunication networks represent reliable ambient energy that can be harvested as they are ubiquitous in urban and suburban areas. The state-of-the-art in RF EH for wearable biomedical sensors specifically targeting the global system of mobile 900/1800 cellular and 700 MHz digital terrestrial television networks as ambient RF energy sources are showcased. Furthermore, guidelines for the choice of the number of stages for the RF energy harvester are presented, depending on the requirements from the embedded system to power supply, which is useful for other researchers that work in the same area. The present authors' recent advances towards the development of an efficient RF energy harvester and storing system are presented and thoroughly discussed too.

15.
Artif Organs ; 39(10): 897-902, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26471141

RESUMO

Multichannel bio-signal recording in undisturbed in vivo conditions is a frequent demand in experimental work for development of methodology and associated equipment for functional electrical stimulation (FES) application, limb prosthesis, and diagnostic tools in contemporary rehabilitation efforts. Intramuscular electromyogram (EMG) recordings can provide comprehensive insight in complex interactions of agonistic and antagonistic muscles during movement tasks and in contrast act as reliable control signals for both neuroprosthesis and mechanical prosthesis. We fabricated a fully implantable device, which is capable of recording electromyography signals from inside a body and transmit these signals wirelessly to an external receiver. The developed analog front end uses only two electrodes per channel, provides a gain of 60 dB, and incorporates a band pass filter with lower cut-off frequency of 4 Hz and upper cut-off frequency of 480 Hz. The bidirectional wireless data link, which operates in the 2.4 GHz Industrial, Scientific and Medical band, is designed for transmission distances of 10 m using an application data rate of 1 kSps for each of the two channels. Performed in vitro tests with the devices coated in epoxy resin and inserted into a phantom with tissue-equivalent characteristics confirmed the functionality of our concept and the measurement results are consistent with those from preceding simulations.


Assuntos
Eletrodos Implantados , Eletromiografia/métodos , Telemetria/métodos , Animais , Terapia por Estimulação Elétrica/métodos , Eletromiografia/instrumentação , Técnicas In Vitro , Músculo Esquelético/fisiologia
16.
Healthc Technol Lett ; 1(1): 37-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26609374

RESUMO

An ultra-low-power wireless transmitter for embedded bionic systems is proposed, which achieves 40 pJ/b energy efficiency and delivers 500 kb/s data using the medical implant communication service frequency band (402-405 MHz). It consumes a measured peak power of 200 µW from a 1.2 V supply while occupying an active area of 0.0016 mm(2) in a 130 nm technology. A modified pulse position modulation technique called saturated amplified signal is proposed and implemented, which can reduce the overall and per bit transferred power consumption of the transmitter while reducing the complexity of the transmitter architectures, and hence potentially shrinking the size of the implemented circuitry. The design is capable of being fully integrated on single-chip solutions for surgically implanted bionic systems, wearable devices and neural embedded systems.

17.
IEEE J Transl Eng Health Med ; 1: 2700109, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-27170854

RESUMO

Obstructive sleep apnea (OSA) is a common sleep disorder found in 24% of adult men and 9% of adult women. Although continuous positive airway pressure (CPAP) has emerged as a standard therapy for OSA, a majority of patients are not tolerant to this treatment, largely because of the uncomfortable nasal air delivery during their sleep. Recent advances in wireless communication and advanced ("bigdata") preditive analytics technologies offer radically new point-of-care treatment approaches for OSA episodes with unprecedented comfort and afforadability. We introduce a Dirichlet process-based mixture Gaussian process (DPMG) model to predict the onset of sleep apnea episodes based on analyzing complex cardiorespiratory signals gathered from a custom-designed wireless wearable multisensory suite. Extensive testing with signals from the multisensory suite as well as PhysioNet's OSA database suggests that the accuracy of offline OSA classification is 88%, and accuracy for predicting an OSA episode 1-min ahead is 83% and 3-min ahead is 77%. Such accurate prediction of an impending OSA episode can be used to adaptively adjust CPAP airflow (toward improving the patient's adherence) or the torso posture (e.g., minor chin adjustments to maintain steady levels of the airflow).

18.
IEEE J Transl Eng Health Med ; 1: 3700207, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-27170858

RESUMO

Contaminated water is a serious concern in many developing countries with severe health consequences particularly for children. Current methods for monitoring waterborne pathogens are often time consuming, expensive, and labor intensive, making them not suitable for these regions. Electrochemical detection in a microfluidic platform offers many advantages such as portability, minimal use of instrumentation, and easy integration with electronics. In many parts of the world, however, the required equipment for pathogen detection through electrochemical sensors is either not available or insufficiently portable, and operators may not be trained to use these sensors and interpret results, ultimately preventing its wide adoption. Counterintuitively, these same regions often have an extensive mobile phone infrastructure, suggesting the possibility of integrating electrochemical detection of bacterial pathogens with a mobile platform. Toward a solution to water quality interventions, we demonstrate a microfluidic electrochemical sensor combined with a mobile interface that detects the sequences from bacterial pathogens, suitable for rapid, affordable, and point-of-care water monitoring. We employ the transduction of DNA hybridization into a readily detectable electric signal by means of a conformational change of DNA stem-loop structure. Using this platform, we successfully demonstrate the detection of as low as 100 nM E. coli sequences and the automatic interpretation and mapping of the detection results via a mobile application.

19.
Sensors (Basel) ; 12(9): 11544-58, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23112669

RESUMO

Intraoral devices for bite-force sensing have several applications in odontology and maxillofacial surgery, as bite-force measurements provide additional information to help understand the characteristics of bruxism disorders and can also be of help for the evaluation of post-surgical evolution and for comparison of alternative treatments. A new system for measuring human bite forces is proposed in this work. This system has future applications for the monitoring of bruxism events and as a complement for its conventional diagnosis. Bruxism is a pathology consisting of grinding or tight clenching of the upper and lower teeth, which leads to several problems such as lesions to the teeth, headaches, orofacial pain and important disorders of the temporomandibular joint. The prototype uses a magnetic field communication scheme similar to low-frequency radio frequency identification (RFID) technology (NFC). The reader generates a low-frequency magnetic field that is used as the information carrier and powers the sensor. The system is notable because it uses an intra-mouth passive sensor and an external interrogator, which remotely records and processes information regarding a patient's dental activity. This permits a quantitative assessment of bite-force, without requiring intra-mouth batteries, and can provide supplementary information to polysomnographic recordings, current most adequate early diagnostic method, so as to initiate corrective actions before irreversible dental wear appears. In addition to describing the system's operational principles and the manufacture of personalized prototypes, this report will also demonstrate the feasibility of the system and results from the first in vitro and in vivo trials.


Assuntos
Força de Mordida , Bruxismo/diagnóstico , Equipamentos para Diagnóstico , Campos Magnéticos , Humanos , Dente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA