Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 252
Filtrar
1.
J Foot Ankle Surg ; 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39147359

RESUMO

Fixation methods for posterior malleolar fracture (PMF) are a source of great controversy. This study aims to compare complications, clinical and radiological outcomes between PA screws and posterior plate in PMF using current literature. A systematic search strategy was conducted following the PRISMA protocol. Medline (PubMed), Embase (Elsevier), and Lilacs databases were used to identify complication rates (infection, non-union, loss of reduction, osteoarthrosis, and sural nerve injury) and to compare reported functional outcomes. The level of evidence in the articles was assessed using the GRADE tool. The studies eligible for meta-analysis were processed using The Review Manager version 5.4.1 software. Twelve articles met the inclusion criteria; five articles were included for subgroup meta-analysis. Overall infection rate, loss of reduction and sural nerve injury were each 2%. Osteoarthritis rate was 10%. There was no difference in risk reduction for infection rate (RD= 0.01; 95% CI: -0.03 - 0.06; p= 0.50), loss of reduction (RD= - 0.00; 95 CI: -0.03 - 0.03; p= 0.88), sural nerve injury (RD= 0.01; 95% CI:-0.03 - 0.04; p= 0.70), osteoarthrosis (RD= -0.00; 95% CI: -0.09 - 0.09; p= 0.97), functional (MD= 0.70; 95% CI: -1.06 - 2.45; p= 0.44) or pain scores (MD= 0.12; 95% CI: -0.31 - 0.55; p= 0.58), nor deficit in dorsiflexion (MD= -0.26; 95% CI: -1.64 - 1.12; p= 0.71). There were no clinical nor radiological significant differences when comparing fixation of PMF with plates or PA screws. With current literature it is not possible to establish the superiority of either fixation.

2.
Rev Bras Ortop (Sao Paulo) ; 59(Suppl 1): e34-e38, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39027185

RESUMO

The most frequent skeletal injuries are hand fractures, which constitute around 20% of all fractures. Fractures of the phalanx are usual, comprising 6% of all fractures. Proximal phalanx fractures arise more often. The main goals of the care are to repair the anatomy, reduce the damage to soft tissue, and mobilize the damaged fingers as soon as stabilization of the fracture allows it. The present report is intended to examine the clinical and radiation effects of proximal phalanx fractures in patients treated with intramedullary screw fixation who underwent closed reduction. We report three consecutive cases of proximal phalanx fracture: two basal fractures and one simple shaft fracture. They were treated surgically with closed reduction with intramedullary headless compression screws. The preoperative magnitude of the angulation of the proximal phalanx averaged 30.3° (range: 13° to 42°). Two patients presented rotational deformity. The clinical findings were measured using the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (Quick-DASH) questionnaire, and the range of motion and functional results were assessed. Complications were observed over a span of at least 3 months. The patients displayed complete active flexion-extension proximal interphalangeal joint and flexion-extension metacarpophalangeal joint without rotative deformity. The scores on the QuickDASH were satisfactory (mean: 2.3; range: 0 to 4.5). No secondary surgeries were performed, and complications were not observed. Intramedullary fixation of proximal phalanx fractures with cannulated tension screws has been shown to be a safe operation, resulting in outstanding functional performance and an early recovery. The fracture is minimized and properly consolidated by the patients.

3.
Foot Ankle Surg ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38824055

RESUMO

PURPOSE: There are two main surgical fixation methods for the posterior malleolar fractures (PMFs), the anterior-to-posterior (AP) screws or via the posterolateral (PL) approach utilizing a buttress plate. This review aims to compare the clinical outcome between the AP screw fixation and the PL plate fixation for treating PMFs. METHODS: We searched all relevant publications about PMFs treated with AP screws or PL plates through electronic databases including the PubMed, the Cochrane Library, the Embase, the Wiley online library and the Web of Science. The meta-analysis was conducted to evaluated clinical outcomes including reduction quality, post-operative function and complications. RESULTS: Six studies (one single randomized controlled trial and five retrospective cohort studies) were enrolled. 172 patients underwent AP screw fixation and 214 patients underwent PL plate fixation with a total of 386 patients (169 males and 217 females). The PL plating group yielded better AOFAS scores(MD = 6.97, 95 % CI=[4.68, 9.27], P<0.00001, I2 =0 %) and was more likely to achieve excellent anatomical reduction(OR=5.49, 95 % CI=[1.06, 28.42], P = 0.04, I2 =80 %). No differences were found in the bad reduction quality, incidences of complications (arthritis, neuralgia, superficial wound healing problems and implant failure), the walking VAS scores and the dorsiflexion restriction degrees. CONCLUSION: We suggest that the PL plate fixation method has the clinical benefit of achieving anatomical reduction and better AOFAS scores over the AP screw fixation for treating PMFs. No differences were found in the incidences of complications ( arthritis, neuralgia, superficial wound healing problems and implant failure), the walking VAS scores and the dorsiflexion restriction degrees. The posterior approach and the direct reduction are recommended for the treatment of the PMFs. LEVEL OF CONFIDENCE: Ⅱb.

4.
Cir Cir ; 92(2): 141-149, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38782391

RESUMO

BACKGROUND: Clavicle fractures represent 2.5-4% of all fractures observed in emergency services. 80% occurs in the middle third. Treatment by plating requires a higher level of evidence. OBJECTIVE: To compare the functional outcomes of mid-shaft clavicle fractures managed with superior plating compared to anteroinferior plating. TRIAL DESIGN: A randomized, double-blind, parallel, superiority clinical trial. PATIENTS AND METHODS: Patients with fractures of the clavicles AO15B1 and AO15B2 were studied. Patients were randomized to be treated with either 3.5 mm superior or anteroinferior plating. A rehabilitation program was designed for both groups. The primary outcome measure was the Disability of Arm, Shoulder, and Hand (DASH) score; secondary outcomes included pain, union rate, and complication rates. RESULTS: Twenty-eight patients were studied and were eligible for analysis. Significant differences were found in the function assessed with the DASH score at 30 days for the superior plating compared with anteroinferior (43.74 vs. 29.26, respectively, p = 0.027), 60 days (23.97 vs. 11.18, p = 0.021), and 90 days (9.52 vs. 3.5, p = 0.016). One loosening with superficial infection was found with superior plating. CONCLUSIONS: Using an anteroinferior reconstruction plate in diaphyseal fractures offers better functional results than the upper plate in patients with fractures of the middle third of the clavicle.


ANTECEDENTES: Las fracturas de clavícula comprenden el 2.5-4% de todas las fracturas observadas en los servicios de emergencia. El 80% se presentan en el tercio medio. La posición de la placa como tratamiento requiere mayor nivel de evidencia. OBJETIVO: Comparar los resultados funcionales de las fracturas diafisarias de clavícula manejadas con placa superior versus placa anteroinferior. MÉTODO: Ensayo clínico aleatorizado, doble ciego, paralelo, de superioridad. Se estudiaron pacientes con fractura diafisaria de clavícula AO15B1 y AO15B2. Se manejaron con placa de reconstrucción de 3.5 mm colocada en forma superior o anteroinferior. Se diseñó un programa de rehabilitación para ambos grupos. El resultado primario fue medido con el cuestionario DASH y los resultados secundarios incluyeron dolor, presencia de consolidación y complicaciones. RESULTADOS: Fueron elegibles para análisis 28 pacientes. Se encontraron diferencias significativas de la escala DASH a los 30 días para la maniobra superior comparada con la inferior (43.74 vs. 29.26, respectivamente; p = 0.027), a los 60 días (23.97 vs. 11.18; p = 0.021) y a los 90 días (9.52 vs. 3.5; p = 0.016). CONCLUSIONES: El uso de placa de reconstrucción anteroinferior en las fracturas diafisarias ofrece mejores resultados funcionales en comparación con la placa superior en pacientes con fracturas de tercio medio de clavícula.


Assuntos
Placas Ósseas , Clavícula , Fixação Interna de Fraturas , Fraturas Ósseas , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Clavícula/lesões , Clavícula/cirurgia , Método Duplo-Cego , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento
5.
Biopolymers ; : e23600, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38808736

RESUMO

Distal ulna locking bone plates (DLBPs) are commonly employed in the treatment of distal ulna fractures. However, commercially available metallic bone plates experience stress shielding and lack corrosion resistance. Poly lactic acid (PLA) is highly favored biopolymer due to its biocompatible and bioabsorbable nature with human tissues. The use of additive layer manufacturing (ALM) is gaining attention for creating customized implants with intricate structures tailored to patient autonomy. ALM-based PLA bone plates must provide high resistance against impact and torsional forces, necessitating the adjustment of printing process parameters. This study focuses on examining the influence of key printing parameters, on the impact strength and torque-withstanding capability of DLBPs. Experimental results, along with microscopic images, reveal that an increase in infill density (IF) and wall thickness imparts strong resistance to layers against crack propagation under impact and torsional loads. On the contrary, an increase in layer height and printing speed leads to delamination and early fracture of layers during impact and torsional testing. IF significantly contributes to improving the impact strength and torque-withstanding capability of DLBPs by 70.53% and 80.65%, respectively. The study highlights the potential of the ALM technique in developing DLBPs with sufficient mechanical strength for biomedical applications.

7.
Trauma Case Rep ; 51: 101018, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38628458

RESUMO

The surgical management of patellar fractures typically yielded satisfactory results; however, in situations involving multifragmented patellar fractures or those affecting the inferior pole, it became imperative to employ alternative osteosynthesis techniques that enhanced stability, enabled early rehabilitation initiation, prevented implant failure, and avoided reduction loss before fracture consolidation. In this context, an unconventional osteosynthesis alternative was presented, utilizing an anatomically designed hook plate originally intended for the fifth metatarsal. This technique was successfully applied in three patients with multifragmentary patellar fractures, allowing stable fixation of small or marginal fragments through the plate's hooks without compromising vascularity. Fracture consolidation was achieved without reduction loss, and owing to its low profile, patient discomfort and irritation were minimized compared to traditional tension band or wiring techniques. This approach suggested the potential to forego early plate removal, thereby contributing to a more effective management of patellar fractures. Level of evidence: IV.

8.
Injury ; 55(6): 111532, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38614015

RESUMO

BACKGROUND: Fixation of sustentaculum tali fractures is important to maintain the biomechanical function of the subtalar joint. A common method of fixation is securing the sustentacular fragment by way of a laterally based locking plate (LP). A medial approach with a single screw (MS) has been proposed as an alternative method of fixation. METHODS: Five pairs of formalin-preserved cadaveric ankles with the subtalar joint and interosseous ligaments intact ("osseous cadavers") and four pairs of fresh-frozen cadaveric ankles with soft-tissue preserved dissected from mid-tibia down ("soft tissue cadavers") were used in the study. The left ankle was randomly assigned to one of the two fixation methods (LP or MS), while the right ankle was the opposite. These same steps for fixation were repeated for six synthetic ankle models. All models were loaded with a body mass of 80 kg. Statistical differences between LP and MS stiffness were determined using a paired t-test in cadavers and un-paired t-tests in synthetic ankles. RESULTS: For osseous cadaveric ankles, LP demonstrated a mean stiffness of 232.95(SD: 59.96) N/mm, while MS was 239.72(SD:131.09) N/mm (p = 0.9293). For soft tissue cadaveric ankles, LP mean stiffness was 133.58(SD:37.84) N/mm, while MS was 134.88(SD:20.75) N/mm (p = 0.9578). For synthetic ankles, LP mean stiffness was 220.40(SD:81.93) N/mm, while MS was 261.50(SD:100.21) N/mm (p = 0.6116). CONCLUSIONS: Across all three models, there was no significant difference between LP and MS methods. Retrospective observational studies are recommended to assess patient outcomes from each of the methods.


Assuntos
Placas Ósseas , Parafusos Ósseos , Cadáver , Fixação Interna de Fraturas , Humanos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Fenômenos Biomecânicos , Fraturas Ósseas/cirurgia , Articulação Talocalcânea/cirurgia , Articulação Talocalcânea/fisiopatologia , Tálus/cirurgia , Tálus/lesões , Fraturas do Tornozelo/cirurgia , Fraturas do Tornozelo/fisiopatologia , Masculino
9.
Rev Bras Ortop (Sao Paulo) ; 59(1): e107-e118, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38524703

RESUMO

Objective: The present study compared the difference in load and pressure distribution behavior of the blade plate and locked plate for varus osteotomy of the proximal femur per the finite element method. Methods: Modeling was performed by scanning a medium-sized left femur with medial valgus deformity made of polyurethane. Results: The stiffness of the locked plate is higher compared with that of the blade plate. However, this difference was not significant. In addition, the locked plate has proximal locking screws to ensure that the bending moments on the screws are smaller during loading. Conclusion: In summary, both plates are well-established and effective. However, the study using the finite element method plays a fundamental role in understanding the load and pressure distribution of the implant. Moreover, it opens up new possibilities for further studies, including surgical proposals and customized implant materials.

10.
Cureus ; 16(1): e53120, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38420078

RESUMO

Extension of existing spinal fusions may necessitate the removal of or linkage to prior constructs. Knowledge of previously placed instrumentation is critical to success in these revision scenarios. The Luque spinal instrumentation system, developed in the late 1980s, is a legacy pedicle screw and plate system that may be encountered during revision operations today. A 67-year-old male with a remote history of L4-S1 fusion with Luque instrumentation presented with bilateral lower extremity neurogenic claudication due to adjacent segment disease at L3-4. Decompression and extension of fusion to the L3-4 level were performed using minimally invasive techniques. Of note, posterior instrumentation was extended by removing prior L4 pedicle screws with a 7 mm female hexagonal driver through tubular retractors, leaving the Luque plates in place, placing modern pedicle screws at L4 (through the plates) and L3, and linking these with standard rods. The surgery and post-operative course were uncomplicated, and the patient experienced complete resolution of his pre-operative claudication symptoms. Extension of prior Luque plate instrumented fusion can be accomplished minimally invasively without removing the plates themselves, resulting in greater operative efficiency and less surgical morbidity.

11.
Rev. bras. ortop ; 59(1): 107-118, 2024. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1559606

RESUMO

Abstract Objective: The present study compared the difference in load and pressure distribution behavior of the blade plate and locked plate for varus osteotomy of the proximal femur per the finite element method. Methods: Modeling was performed by scanning a medium-sized left femur with medial valgus deformity made of polyurethane. Results: The stiffness of the locked plate is higher compared with that of the blade plate. However, this difference was not significant. In addition, the locked plate has proximal locking screws to ensure that the bending moments on the screws are smaller during loading. Conclusion: In summary, both plates are well-established and effective. However, the study using the finite element method plays a fundamental role in understanding the load and pressure distribution of the implant. Moreover, it opens up new possibilities for further studies, including surgical proposals and customized implant materials.


Resumo Objetivo: Testar a diferença do comportamento de distribuição de cargas e pressões da placa lâmina comparativamente com a placa bloqueada para osteotomia varizante do fêmur proximal através do método de elementos finitos. Métodos: A modelagem foi realizada através do escaneamento de um fêmur esquerdo com deformidade medial em valgo fabricado em poliuretano de tamanho médio. Resultados: Como resultados, pode-se inferir que a rigidez da placa bloqueada é maior do que a da placa lâmina. No entanto, essa diferença não foi significativa e, além disso, a placa bloqueada possui parafusos de travamento proximal para garantir que os momentos de flexão que agem nos parafusos sejam ainda menores durante o carregamento. Conclusão: Em síntese, ambos os materiais são consagrados e eficazes para serem utilizados, porém o estudo pelo método de elementos finitos apresenta papel importante para compreendermos a situação de distribuição de cargas e pressões do implante e abre novas possibilidades para novos estudos, como, por exemplo, o estudo da proposta cirúrgica e materiais a serem implantados de forma individual e personalizada.


Assuntos
Humanos , Medição da Dor , Entrevistas como Assunto , Inquéritos e Questionários , Síndromes da Dor Regional Complexa , Fixação de Fratura
12.
Adv Biomed Res ; 12: 206, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38073722

RESUMO

Background: Tibial plateau fractures have become more frequent in recent years. The most prevalent Schatzker classification is type II, which is a lateral tibial plateau fracture with depression. Our null hypothesis was that the 3.5 T-plate and the 4.5 T-plate have no difference in the management of patients with Schatzker type II tibial plateau fractures. Materials and Methods: The current study is a clinical trial that was conducted on patients with tibial plateau fractures. The Knee Society Score (KSS) was this study's main outcome. Tourniquet time (TT) and patient quality of life using the 36-item Short Form Survey Instrument (SF-36) were secondary goals of the outcomes measurement study. VAS measured pain. Among 176 patients, 89 and 87 of cases underwent surgical treatment with 3.5-mm (group A) and 4.5-mm (group B) T-plate, respectively. The data were entered into SPSS software (version 25, IBM Corporation, Armonk, NY) and analyzed. Results: In our study, we evaluated 176 patients with a mean age of 34.8 ± 15.2 years. Functional and clinical KSS scores were similar between the two groups throughout follow-up (P > 0.05). Regarding the other variables of VAS, TT, SF-36 physical function, and SF-36 mental health, no significant difference was observed between the two groups, and the two groups had similar averages in terms of these indicators (P > 0.05). Conclusion: According to the results, both plates had the appropriate functional outcomes in patients with split depression tibial plateau fracture.

13.
Rev Bras Ortop (Sao Paulo) ; 58(6): e896-e904, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38077774

RESUMO

Objective Various modalities have been suggested to manage mallet fractures; however, inappropriate treatment can lead to extension lag, a swan neck deformity, or arthritis of the distal interphalangeal joint (DIPJ). The current study aimed to evaluate the results (functional, radiological, and complications) of open reduction and internal fixation (ORIF) of mallet fractures using low-cost hook plates fabricated from low-profile titanium mini plates. Methods A prospective case series of 17 consecutive patients (average age of 32.3 years) with mallet fractures (six were Wehbe Type IB and 11 were Wehbe Type IIB). Eleven (64.7%) were males. The affected hand was dominant in all patients, and the affected digit was the index in 6 (35.3%), the ring in 5 (29.4%), the small in 3 (17.65%), and the middle in 3 (17.65%) patients. The same fellowship-trained hand surgeon performed all surgeries. Results The average operative time was 37.65 minutes. After an average follow-up of 10.94 months (range 6-27), the average DIPJ motion was 50° ° (range 20°-70°), the extensor lag was noted in 4 (23.5%) patients, and complications were reported in 6 (35.29%) patients. According to Crawford criteria, 6 (35.3%) patients achieved excellent results, 7 (41.2%) achieved good results, and 4 (23.5%) achieved fair results. Conclusion The modified hook plate technique for fixation of mallet fractures is a beneficial, economical, yet demanding technique that adequately provides stable fixation to allow early DIPJ motion with acceptable functional outcomes.

14.
Odontol. vital ; (39): 27-39, jul.-dic. 2023. tab, graf
Artigo em Espanhol | LILACS, SaludCR | ID: biblio-1550585

RESUMO

RESUMEN Introducción: Los tratamientos para fracturas de órbita se basan en la corrección del defecto de las lesiones orbitarias de tipo blow in y blow out (o de estallido), mediante diversas placas y mallas biocompatibles con el organismo, dándose una cicatrización de primera generación evitando un callo óseo y una fijación más rígida. Para el diagnóstico de este tipo de lesiones tenemos inflamación periorbitaria, enoftalmos, diplopía, equimosis, hemorragia subconjuntival. Existen diversos materiales reconstructivos siendo estos compuestos por distintas materias primas, como son los aloplásticos y autógenos; donde encontramos varios tipos como placas de titanio y las placas reabsorbibles siendo estas las más comunes y usadas actualmente, por su bajo estímulo a reabsorciones óseas y evitando efectos secundarios a largo plazo. Estas placas presentan diversos grados de ductilidad y resistencia. Se informó sobre varias complicaciones según el tipo de placas como es la cicatrización, las cirugías postquirúrgicas en caso de placas de titanio, etc. El objetivo de esta revisión es la evaluación de la eficacia las placas reabsorbibles versus placas de titanio en fracturas de órbita. Materiales y métodos: La investigación es de carácter documental, descriptivo y no experimental. En el cual se emplea una metodología de identificación e inclusión de artículos científicos tipo prisma. Resultados y conclusiones: Se verificaron las ventajas y desventajas tanto de las placas reabsorbibles como las de titanio siendo estas similares en la biocompatibilidad con el organismo humano, así como también varias diferencias como el soporte, fuerzas, resistencia de estas, concluyendo que es debatible el material ideal para tratar fracturas de órbita. Se seleccionaron artículos tomando en cuenta el título y objetivos; considerando estudios comparativos, revisiones sistemáticas, revisiones de literatura, los cuales comprendían criterios con respecto a fracturas de órbita y tratamientos quirúrgicos. La búsqueda arrojó 55 artículos en PubMed, 65 en Google, 4 en Scielo y 29 en Science direct, de los cuales se excluyeron libros, monografías, estudios experimentales, dando como resultado 21 artículos para el desarrollo de esta revisión bibliográfica. Y que fueron leídos y analizados en su totalidad, estudiando los objetivos, metodología y conclusión de cada uno de ellos para la posterior comparación.


ABSTRACT Introduction: Treatments for orbit fractures are based on the correction of the defect of blow in and blow out orbital injuries, by means of various plates and meshes biocompatible with the organism, giving a first-generation healing avoiding a bony callus and a more rigid fixation. For the diagnosis of this type of lesions we have periorbital inflammation, enophthalmos, diplopia, ecchymosis, subconjunctival hemorrhage. There are several reconstructive materials being these composed of different raw materials, such as alloplastic and autogenous, where we find several types such as titanium plates and resorbable plates being these the most common and currently used, for its low stimulus to bone resorption and avoiding long-term side effects. These plates have different degrees of ductility and resistance. Several complications have been reported depending on the type of plates, such as scarring, post-surgical surgeries in the case of titanium plates, etc. The objective of this review is to evaluate the efficacy of resorbable versus titanium plates in orbital fractures. Materials and methods: This research are a documentary, descriptive and non-experimental nature. A prism-type methodology of identification and inclusion of scientific articles was used. Results and conclusions: The advantages and disadvantages of both resorbable and titanium plates were verified, being these similar in biocompatibility with the human organism, as well as several differences such as support, forces, resistance of the same, concluding that it is debatable. The ideal material to treat orbital fractures. Articles were selected considering the title and objectives; considering comparative studies, systematic reviews, literature reviews, which included criteria regarding orbital fractures and surgical treatments. The search yielded 55 articles in PubMed, 65 in Google, 4 in Scielo and 29 in Science direct, from which books, monographs, experimental studies were excluded, resulting in 21 articles for the development of this bibliographic review. The 21 articles were read and analyzed in their entirety, studying the objectives, methodology and conclusion of each one of them for subsequent comparison.


Assuntos
Humanos , Órbita/lesões , Placas Ósseas , Titânio , Materiais Biocompatíveis/uso terapêutico , Fraturas Ósseas/cirurgia
15.
Clin Orthop Surg ; 15(5): 843-852, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37811514

RESUMO

Background: Surgery of the medial end of the clavicle remains a challenge for orthopedic surgeons. Moreover, there is no standard surgical procedure for treating displaced fractures or dislocation of the medial clavicle. Thus, the present study aimed to evaluate the safety and efficacy of using a hook plate for treating medial-end clavicular fractures and present functional outcomes. Methods: We retrospectively investigated 18 patients who underwent surgery with a hook plate from July 2016 to December 2021. There were 14 men and 4 women with a mean age of 57.4 years. Fracture union was assessed at follow-up by computed tomography (CT). Other outcome parameters were complications, including implant failure, infection, nonunion, osteolysis of sternal manubrium, and migration of the hook portion. Range of motion (ROM), visual analog scale (VAS), Quick Disabilities of the Arm, Shoulder and Hand (Quick DASH), and American Shoulder and Elbow Society (ASES) scores were evaluated 6 months postoperatively and at the last follow-up. Results: The mean operation time was 43.8 minutes (range, 35-50 minutes) and the mean follow-up was 22.8 months (range, 12-42 months). Bone union was confirmed in all cases. The mean union time was 6.2 months (range, 6-7 months). Implant removal was performed routinely according to the clinical course in 17 cases. The mean implant removal time was 10.0 months (range, 6-14 months). Clinical and functional outcomes measured at the last follow-up were significantly improved compared to those at 6 months postoperatively (p < 0.05). Regarding complications, there were 6 cases (33.3%) of osteolysis of the sternal manubrium. Although the anteroposterior length of the manubrium and hook depth showed significant differences between the non-osteolysis group and the osteolysis group (p = 0.024), ROM, VAS, Quick DASH, and ASES scores were not significantly different between the two groups (all p > 0.05). Conclusions: Clavicle hook plating can be a safe and effective method that can be easily applied with good outcomes if it is used with appropriate surgical planning and technique for medial-end clavicle fracture. CT scans are useful for preoperative planning and postoperative evaluation of bone union or complications.


Assuntos
Fraturas Ósseas , Osteólise , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Resultado do Tratamento , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos , Placas Ósseas
16.
J Dent ; 137: 104650, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37544353

RESUMO

OBJECTIVES: Surgeons often encounter challenges when treating maxillofacial fractures using conventional methods that involve trimming or bending ready-made titanium plates for open reduction and internal fixation (ORIF) since it can be time-consuming, imprecise, and inconvenient. This retrospective case series aimed to introduce a novel bone reduction method that utilizes virtual planning, patient-specific surgical guides, and titanium plates. METHODS: Seven patients with mandibular symphysis or subcondylar fractures resulting from facial trauma underwent cone-beam computed tomography (CBCT) or facial CT scans, and their medical histories were documented. Virtual surgery was conducted based on three-dimensional (3D) stereolithography images derived from CT scans using the FaceGide software (MegaGen, Daegu, Korea). ORIF was performed using patient-specific surgical guides and plates that were designed, printed, and milled. Radiographic, clinical, and occlusal evaluations were conducted at two weeks and six weeks postoperatively. Subsequently, 3D images from virtual surgery and postoperative CT scans were compared. RESULTS: The comparison of 3D virtual surgery and postoperative images revealed minimal surface differences of less than 1 mm. T-scan evaluations indicated that there were no statistically significant differences between the two- and six-week postoperative assessments. Favorable clinical outcomes were observed. CONCLUSION: This novel method demonstrated stable outcomes in terms of occlusion and healing, with no notable complications. Consequently, this approach may serve as a viable alternative to conventional methods. CLINICAL SIGNIFICANCE: Facial fracture surgery that utilizes patient-specific surgical guides and plates within a digital workflow can facilitate meticulous surgical planning, reducing the risk of complications and minimizing operation time.


Assuntos
Fixação Interna de Fraturas , Fraturas Ósseas , Humanos , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Titânio , Fraturas Ósseas/cirurgia , Tomografia Computadorizada por Raios X
17.
Br J Oral Maxillofac Surg ; 61(5): 362-367, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37263889

RESUMO

The aim of this study was to comparatively analyse osseointegration after the implantation of self-tapping screws (STS) and self-drilling screws (SDS). Thus, 24 four-month-old male Wistar rats, received SDS and STS screws in their left and right tibias, respectively. Sample collection was performed immediately at 0 hours (0h), two, seven, and 21 days after implantation (2d, 7d, 21d). Samples from immediately and 21 days after were analysed by micro computed tomography (MicroCT). All time points were evaluated by histology (Haematoxylin and Eoisin and Goldner's Trichrome) and immunohistochemistry for tartrate-acid resistant phosphatase positive (TRAP+) osteoclasts. MicroCT images revealed an intimate contact between bone and each type of screw at 0h. However, SDS group presented decreased bone volume (BV, mm3) at 21 days in comparison with STS. Both SDS and STS post implantation presented areas of suitable new bone formation surrounding screw threads from seven days, and inflammation decreased from two to 21 days. Also, TRAP+ osteoclasts were mainly identified at seven days in both STS and SDS groups, particularly surrounding areas of pressure, with significant differences between groups. In conclusion, differences in shape and insertion technique for SDS and STS screws did not affect immediate and late inflammatory and bone healing response post implantation in this animal model. Both osteosynthesis screws allowed satisfactory post-surgical outcomes.


Assuntos
Parafusos Ósseos , Osso e Ossos , Animais , Ratos , Masculino , Ratos Wistar , Microtomografia por Raio-X , Fixação Interna de Fraturas
18.
J Mech Behav Biomed Mater ; 143: 105929, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37263171

RESUMO

The metallic biomaterials have been proclaimed to exhibit stress shielding with discharge of toxic ions, leading to polymeric implants attracting interest in 3D Printing domain. In this study, Poly Lactic Acid based 336 bone plates are fabricated using Fused Filament Fabrication with printing parameters being varied. Polydopamine, being biocompatible, is deposited on fabricated bone plates at varying submersion time, shaker speed and coating solutions concentration. The study involves witnessing the effect of printing and coating parameters on biological behavior of bone plates upon preservation in Simulated Body Fluid and Hank's Balanced Salt Solution. The findings propose the close relation of degradation with apatite growth. The highest degradation rate with significant reduction in mechanical characteristics are shown by uncoated bone plates. These bone plates have porous structure at 20% infill density, 0.5 mm layer height, 0.4 mm wall thickness and 100 mm/s print speed which could result in complete degradation with partial healing of bone fracture. The study suggests the preservation of bone plates coated at 120 h' submersion time and 120 RPM shaker speed in 3 mg/ml concentrated solution which showed lower apatite formation. Thus, the coating would slow down degradation of PLA bone plates, resulting in complete healing of bone fracture.


Assuntos
Placas Ósseas , Fraturas Ósseas , Humanos , Poliésteres/química , Apatitas/química , Ácido Láctico/química , Impressão Tridimensional , Atenção à Saúde
19.
Rev Bras Ortop (Sao Paulo) ; 58(2): 326-330, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37252299

RESUMO

Objective Medial open wedge high tibial osteotomy (MOWHTO) significantly relieves pain in the medial joint line in medial compartment osteoarthritis of the knee. But some patients complain of pain over the pes anserinus even 1 year after the osteotomy, which may require implant removal for relief. This study aims to define the implant removal rate after MOWHTO due to pain over the pes anserinus. Methods One hundred and three knees of 72 patients who underwent MOWHTO for medial compartment osteoarthritis between 2010 and 2018 were enrolled in the study. Knee injury and osteoarthritis outcome score (KOOS), Oxford knee score (OKS), and visual analogue score (VAS) were assessed for pain in the medial knee joint line (VAS-MJ) preoperatively, 12 months postoperatively, and yearly thereafter; adding VAS for pain over the pes anserinus (VAS-PA). Patients with VAS-PA ≥ 40 and adequate bony consolidation after 12 months were recommended implant removal. Results Thirty-three (45.8%) of the patients were male and 39 (54.2%) were female. The mean age was 49.4 ± 8.0 and the mean body mass index was 27.0 ± 2.9. The Tomofix medial tibial plate-screw system (DePuy Synthes, Raynham, MA, USA) was used in all cases. Three (2.8%) cases with delayed union requiring revision were excluded. The KOOS, OKS, and VAS-MJ significantly improved 12 months after MOWHTO. The mean VAS-PA was 38.3 ± 23.9. Implant removal for pain relief was needed in 65 (63.1%) of the103 knees. The mean VAS-PA decreased to 4.5 ± 5.6 3 months after implant removal ( p < 0.0001). Conclusion Over 60% of the patients may need implant removal to relieve pain over the pes anserinus after MOWHTO. Candidates for MOWHTO should be informed about this complication and its solution.

20.
Front Surg ; 10: 1170760, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37228760

RESUMO

We reported 2 cases of patellar tendon rupture at the lower pole of the patella. For patellar tendon rupture, simple suture fixation has been proved to be inadequate in strength. Our center uses custom-made anchor-like plate and suture to treat proximal patellar fracture. The fixation strength is reliable, no additional bone tunnel is required, and the fixation of the lower patellar fracture can be achieved at the same time. After the operation, the patient starts functional exercise of the knee joint at an early stage, The function of the knee joint of the patient recovered well after 1 year, without other complications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA