Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
1.
J Hist Neurosci ; : 1-42, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38921955

RESUMO

The foundation by Jean-Martin Charcot (1825-1893) of the Salpêtrière School in Paris had an influential role in the development of neurology during the late-nineteenth century. The international aura of Charcot attracted neurologists from all parts of the world. We here present the most representative European, American, and Russian young physicians who learned from Charcot during their tutoring or visit in Paris or Charcot's travels outside France. These include neurologists from Great Britain and Ireland, the United States, Germany and Austria, Switzerland, Russia, Italy, Spain, Belgium and the Netherlands, Scandinavia and Finland, Poland, Bohemia, Hungary, and Romania. Particularly emblematic among the renowned foreign scientists who met and/or learned from Charcot were Charles-Edouard Brown-Séquard, who had interactions with Paris University and contributed to the early development of British and American neurological schools; John Hughlings Jackson, who was admired by Charcot and influenced French neurology similarly as Charcot did on British neurology; Silas Weir Mitchell, the pioneer in American neurology; Sigmund Freud, who was trained by Charcot to study patients with hysteria and then, back in Vienna, founded a new discipline called psychoanalysis; Aleksej Yakovlevich Kozhevnikov and almost all the founders of the Russian institutes of neurology who were instructed in Paris; and Georges Marinesco, who established the Romanian school of neurology and did major contributions thanks to his valuable relation with Charcot and French neurology.

2.
Front Neurol ; 15: 1335795, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38895696

RESUMO

Brown-Séquard Syndrome (BSS) is a rare neurological condition caused by a unilateral spinal cord injury (SCI). Upon initial ipsilesional hemiplegia, patients with BSS typically show substantial functional recovery over time. Preclinical studies on experimental BSS demonstrated that spontaneous neuroplasticity in descending motor systems is a key mechanism promoting functional recovery. The reticulospinal (RS) system is one of the main descending motor systems showing a remarkably high ability for neuroplastic adaptations after incomplete SCI. In humans, little is known about the contribution of RS plasticity to functional restoration after SCI. Here, we investigated RS motor drive to different muscles in a subject with Brown-Séquard-plus Syndrome (BSPS) five months post-injury using the StartReact paradigm. RS drive was compared between ipsi- and contralesional muscles, and associated with measures of functional recovery. Additionally, corticospinal (CS) drive was investigated using transcranial magnetic stimulation (TMS) in a subset of muscles. The biceps brachii showed a substantial enhancement of RS drive on the ipsi- vs. contralesional side, whereas no signs of CS plasticity were found ipsilesionally. This finding implies that motor recovery of ipsilesional elbow flexion is primarily driven by the RS system. Results were inversed for the ipsilesional tibialis anterior, where RS drive was not augmented, but motor-evoked potentials recovered over six months post-injury, suggesting that CS plasticity contributed to improvements in ankle dorsiflexion. Our findings indicate that the role of RS and CS plasticity in motor recovery differs between muscles, with CS plasticity being essential for the restoration of distal extremity motor function, and RS plasticity being important for the functional recovery of proximal flexor muscles after SCI in humans.

3.
Am J Emerg Med ; 80: 229.e5-229.e7, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38664103

RESUMO

Brown-Séquard Syndrome (BSS) is a rare form of incomplete spinal cord injury and is characterized by ipsilateral motor deficit and contralateral sensory loss. BSS is commonly associated with traumatic etiologies, but non-traumatic causes should be considered as well. A 38-year-old woman presented with a 3-week history of weakness in her right upper extremity, and she has developed numbness and tingling in her left upper and lower extremities over the past week and a half, along with some motor difficulty. Imaging showed a large right paracentral disc protrusion at the C3-C4 level causing severe spinal canal narrowing and resulting in abnormal cord signal. The patient subsequently underwent a C3-4 cervical total disk replacement. Hemovac placed during surgery was removed on post-op day one, and she was re-evaluated by PT/OT and recommended for outpatient therapies on post-op day two. Our case, along with a review of the literature, highlights those non-traumatic causes of BSS should be considered as a cause of BSS. BSS produced by a herniated cervical disc is extremely rare and is often misdiagnosed.


Assuntos
Síndrome de Brown-Séquard , Vértebras Cervicais , Deslocamento do Disco Intervertebral , Humanos , Síndrome de Brown-Séquard/etiologia , Síndrome de Brown-Séquard/diagnóstico , Feminino , Adulto , Vértebras Cervicais/diagnóstico por imagem , Deslocamento do Disco Intervertebral/complicações , Deslocamento do Disco Intervertebral/diagnóstico , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Deslocamento do Disco Intervertebral/cirurgia , Imageamento por Ressonância Magnética
4.
Arch. argent. pediatr ; 122(1): e202202978, feb. 2024. ilus, tab
Artigo em Inglês, Espanhol | LILACS, BINACIS | ID: biblio-1525840

RESUMO

El síndrome de Brown-Séquard es el conjunto de signos y síntomas causado por hemisección medular de diversos orígenes. Puede generarse por múltiples causas; las traumáticas son las más frecuentes. Las causas menos frecuentes son patología inflamatoria, isquémica, tumoral o infecciosa. Se presenta un niño de 12 años, con instauración aguda y progresiva de un síndrome de hemisección medular derecho, con parálisis hipo/arrefléctica homolateral y afectación de sensibilidad termoalgésica contralateral. En la resonancia magnética de médula espinal, se observó compromiso inflamatorio en hemimédula derecha a nivel de segunda y tercera vértebras torácicas. Con diagnóstico de mielitis transversa idiopática, inició tratamiento con corticoide intravenoso a altas dosis con evolución clínica favorable y restitución de las funciones neurológicas.


Brown-Séquard syndrome refers to a set of signs and symptoms caused by hemisection of the spinal cord from various sources. It may have multiple causes; traumatic injuries are the most frequent ones. The less common causes include inflammation, ischemia, tumors, or infections. This report is about a 12-year-old boy with an acute and progressive course of right hemisection of the spinal cord, with ipsilateral hypo/areflexic paralysis and contralateral loss of thermalgesic sensation. The MRI of the spinal cord showed inflammation in the right side of the spinal cord at the level of the second and third thoracic vertebrae. The patient was diagnosed with idiopathic transverse myelitis and was started on intravenous high-dose corticosteroids; he showed a favorable clinical course and recovered neurological functions.


Assuntos
Humanos , Masculino , Criança , Traumatismos da Medula Espinal/complicações , Síndrome de Brown-Séquard/diagnóstico , Síndrome de Brown-Séquard/etiologia , Mielite , Imageamento por Ressonância Magnética , Inflamação/complicações
5.
Arch Argent Pediatr ; 122(1): e202202978, 2024 02 01.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37594647

RESUMO

Brown-Séquard syndrome refers to a set of signs and symptoms caused by hemisection of the spinal cord from various sources. It may have multiple causes; traumatic injuries are the most frequent ones. The less common causes include inflammation, ischemia, tumors, or infections. This report is about a 12-year-old boy with an acute and progressive course of right hemisection of the spinal cord, with ipsilateral hypo/areflexic paralysis and contralateral loss of thermalgesic sensation. The MRI of the spinal cord showed inflammation in the right side of the spinal cord at the level of the second and third thoracic vertebrae. The patient was diagnosed with idiopathic transverse myelitis and was started on intravenous high-dose corticosteroids; he showed a favorable clinical course and recovered neurological functions.


El síndrome de Brown-Séquard es el conjunto de signos y síntomas causado por hemisección medular de diversos orígenes. Puede generarse por múltiples causas; las traumáticas son las más frecuentes. Las causas menos frecuentes son patología inflamatoria, isquémica, tumoral o infecciosa. Se presenta un niño de 12 años, con instauración aguda y progresiva de un síndrome de hemisección medular derecho, con parálisis hipo/arrefléctica homolateral y afectación de sensibilidad termoalgésica contralateral. En la resonancia magnética de médula espinal, se observó compromiso inflamatorio en hemimédula derecha a nivel de segunda y tercera vértebras torácicas. Con diagnóstico de mielitis transversa idiopática, inició tratamiento con corticoide intravenoso a altas dosis con evolución clínica favorable y restitución de las funciones neurológicas.


Assuntos
Síndrome de Brown-Séquard , Mielite , Traumatismos da Medula Espinal , Masculino , Humanos , Criança , Síndrome de Brown-Séquard/diagnóstico , Síndrome de Brown-Séquard/etiologia , Imageamento por Ressonância Magnética , Inflamação/complicações , Traumatismos da Medula Espinal/complicações
6.
Clin Case Rep ; 11(12): e8246, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38111513

RESUMO

Key clinical message: Spinal cord herniation is an uncommon diagnosis. There should be a high index of suspicion to diagnose spinal cord herniation when a patient presents with incomplete neurological deficits. Surgical repair of the hernia can have postoperative complications with new neurological deficits and they should be considered during the treatment. Abstract: A 37-year-old male presented with insidious onset upper back pain and altered sensations of pain and temperature over the right half of the body below the nipple for 2 months. MRI of the thoracic spine showed an anterolateral defect (left) at the level of T2-T3 vertebra. The defect was covered by a dural graft and the wound was closed with a drain On the 3rd postoperative day, neurological weakness progressed to paraplegia. Patient was treated by exploration and decompression of the hematoma. The deficits were completely recovered at one-month follow-up. Patients with spinal cord herniation and neurologic deficits when treated timely have good outcomes.

7.
J Med Case Rep ; 17(1): 510, 2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38017566

RESUMO

BACKGROUND: Thoracic disc herniation is relatively uncommon, accounting for less than 1% of all spinal herniations. Although most often asymptomatic, they may represent a rare cause of spinal cord ischemia. CASE REPORT: We report the case of a healthy 43-year-old North African male who presented with a Brown-Sequard syndrome revealing a spinal cord ischemia caused by a thoracic disc extrusion. The initial MRI revealed a calcified disc extrusion at the level of T5-T6 without significant spinal cord compression or signal abnormality. A pattern consistent with a medullary ischemia only appeared 48 h later. The patient was treated conservatively with Aspirin and Heparin, which were discontinued later because of a negative cardiovascular work-up. The calcified disc extrusion, which was later recognized as the cause of the ischemia, decreased spontaneously over time and the patient recovered within a few months. CONCLUSIONS: Our case highlights the challenge in diagnosing and managing this uncommon condition. We propose a literature review showing the different therapeutic strategies and their corresponding clinical outcomes.


Assuntos
Síndrome de Brown-Séquard , Deslocamento do Disco Intervertebral , Isquemia do Cordão Espinal , Humanos , Masculino , Adulto , Síndrome de Brown-Séquard/diagnóstico por imagem , Síndrome de Brown-Séquard/etiologia , Hérnia , Deslocamento do Disco Intervertebral/complicações , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Imageamento por Ressonância Magnética , Isquemia do Cordão Espinal/complicações , Isquemia
8.
Cureus ; 15(10): e46917, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37954796

RESUMO

Nonmissile penetrating spine injury represents a small percentage of spinal cord injuries (SCIs), estimated at 0.8% in Western countries. This paper presents a detailed case report of a 28-year-old man with a history of substance use who suffered multiple injuries following a violent incident. The patient was found with a knife embedded in his thoracic spine, prompting immediate medical intervention. Computed tomography and postoperative magnetic resonance imaging revealed the extent of spinal cord and anatomical involvement. A thorough physical medicine and rehabilitation evaluation was conducted post-surgery, leading to a diagnosis of Brown-Séquard syndrome with associated sensorimotor deficits. This paper highlights the challenges posed by penetrating SCIs while reviewing the literature.

9.
Brain Spine ; 3: 101785, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38021003

RESUMO

Introduction: Chronic Idiopathic Spinal Cord Herniation (ISCH) is a very rare spinal cord deformation occurring predominantly in thoracic levels. ISCH lead to progressive myelopathy, spastic paraparesis and Brown Séquard syndrome. Research question: We want to hypothesize that a) the herniated segment can regain its function after untethering despite long-term and complete neurologic dysfunction. b) Intraoperative Electrophysiologic Monitoring (IOEPM) may identify intraoperative changes by monitoring specific neural pathways confirming the efficacy of the intervention in the forthcoming cases. Material & method: It is a retrospective review of data of two cases prospectively collected showing improvement of neurological deficit in cases of ISCH in thoracic levels. We describe two patients with progressive neurological deficits due to ISCH who underwent surgery using electrophysiologic monitoring and have been followed to reach remarkable clinical improvement. Results: The spastic paraparesis of the first case improved remarkably after surgery. Complete foot drop of the other case, persistent for 7 months before intervention, improved after the release of the herniated segment of the cord. Peroperative electrophysiological monitoring did not show changes during surgery. Conclusion: We want to hypothesize that the herniated segment can regain its function after untethering despite long-term and complete neurologic dysfunction. Intraoperative Electrophysiologic Monitoring (IOEPM) may confirm the efficacy of the intervention in the forthcoming cases.

10.
J Surg Case Rep ; 2023(9): rjad514, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37727223

RESUMO

Spinal extradural arachnoid cysts are rare benign lesions occurring along the cerebrospinal axis. They may be associated with pain or varying degrees of neurological compressive symptoms. Brown-Sequard syndrome is a rare sequalae, where there is ipsilateral upper motor neuron paralysis with loss of proprioception as well as contralateral loss of pain and temperature sensation below the lesion. We present a 33-year-old female with a 6-month history of worsening right lower limb weakness and a 2-month history of right lower limb pain. Motor examination revealed right lower limb weakness as well as exaggerated knee and ankle jerk reflexes. A magnetic resonance imaging (MRI) was done, which showed an eccentrically located T4-7 cystic extradural mass causing severe cord compression. She had T4-7 laminectomies with total excision of the cyst and disconnection of the fistulous tract between the cyst and the subarachnoid space. She made full neurologic recovery with no complications.

11.
BMC Musculoskelet Disord ; 24(1): 722, 2023 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-37697343

RESUMO

BACKGROUND: There are some cases of Klippel-Feil syndrome with spinal cord injury in clinical work. However, there is no literature report on Brown-Sequard syndrome after trauma. We report a case of Brown-Sequard syndrome following minor trauma in a patient with KFS type III. Her Brown-Sequard syndrome is caused by Klippel-Feil syndrome. CASE PRESENTATION: We found a 38-year-old female patient with KFS in our clinical work. She was unconscious on the spot following a minor traumatic episode. After treatment, her whole body was numb and limb activity was limited. Half an hour later, she felt numb and weak in the right limb and weak in the left limb. She had no previous hypertension, diabetes, or coronary heart disease. After one-month treatment of medication, hyperbaric oxygen, rehabilitation, and acupuncture in our hospital, her muscle strength partially recovered, but the treatment effect was still not satisfactory. Then, she underwent surgical treatment and postoperative comprehensive treatment, and rehabilitation training. She was able to take care of herself with assistance, and her condition improved from grade B to grade D according to the ASIA (ASIA Impairment Scale) classification. CONCLUSION: KFS, also known as short neck deformity, is a kind of congenital deformity characterized by impaired formation and faulty segmentation of the cervical spine, often associated with abnormalities of other organs. The cervical deformity in patients with KFS can alter the overall mechanical activity of the spine, as well as the compensatory properties of the spine for decelerating and rotatory forces, thus increasing the chance of spinal cord injury (SCI) following trauma. Many mechanisms can make patients more susceptible to injury. Increased range of motion of the segment adjacent to the fused vertebral body may lead to slippage of the adjacent vertebral body and altered disc stress, as well as cervical instability. SCI can result in complete or incomplete impairment of motor, sensory and autonomic nervous functions below the level of lesion. This woman presented with symptoms of BSS, a rare neurological disorder with incomplete SCI. Judging from the woman's symptoms, we concluded that previously she had KFS, which resulted in SCI without fracture and dislocation following minor trauma, with partial BSS. After the comprehensive treatment of surgery, hyperbaric oxygen, rehabilitation therapy, and neurotrophic drugs, two years later, we found her symptoms significantly improved, with ASIA Impairment Scale from grade B to grade D, and her ability to perform activities of daily living with aids.


Assuntos
Síndrome de Brown-Séquard , Síndrome de Klippel-Feil , Traumatismos da Medula Espinal , Humanos , Feminino , Adulto , Síndrome de Klippel-Feil/complicações , Síndrome de Brown-Séquard/diagnóstico por imagem , Síndrome de Brown-Séquard/etiologia , Síndrome de Brown-Séquard/cirurgia , Atividades Cotidianas , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia
12.
J Pak Med Assoc ; 73(8): 1732-1734, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37697774

RESUMO

Spinal cord injury without radiographic abnormality (SCIWORA) is a term that denotes clinical symptoms of traumatic myelopathy without radiographic or computed tomographic features of vertebral fracture or instability. However, SCIWORA in adults is very rare, especially that involving the thoracic spine. We describe the case of a 38-year-old man who complained of weakness in the right lower extremity for two hours. The injury occurred due to rapid spinal cord rotation-stretching. The patient was diagnosed with SCIWORA at the T4 level, manifesting as Brown-Sequard syndrome (BBS). Finally, he was able to walk independently without assistance after two-month treatment. SCIWORA due to spinal cord rotation-stretching injury, manifesting as BSS, is a very rare mechanism of injury. When X-ray and CT scans rule out the diagnosis of spinal fractures, SCIWORA should be suspected. We recommend that clinicians should have a comprehensive and systematic understanding of this disease to greatly reduce misdiagnosis and improve the level of treatment.


Assuntos
Síndrome de Brown-Séquard , Traumatismos da Medula Espinal , Fraturas da Coluna Vertebral , Adulto , Masculino , Humanos , Síndrome de Brown-Séquard/diagnóstico por imagem , Síndrome de Brown-Séquard/etiologia , Rotação , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/diagnóstico por imagem , Perna (Membro)
13.
Front Surg ; 10: 1238448, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37614664

RESUMO

Objective: The pathophysiology of idiopathic spinal cord herniation remains unknown. However, several different factors have been postulated, such as congenital causes (ventral dura mater duplication, preexisting pseudomeningocele, or other congenital dural defects), inflammation, remote spinal trauma, or thoracic disc herniation. Herein, the diagnosis and surgical treatment of a patient with spinal cord herniation caused by an intraspinal bone spur is presented along with a relevant literature review. Case presentation: A 56-year-old male patient presented with a non-traumatic Brown-Sequard syndrome persisting for over 1 year. A magnetic resonance imaging of the spinal axis revealed a ventral spinal cord displacement in the level of T 6/7. A supplementary thin-sliced computed tomography of the spine revealed a bone spur at the same level. For neurosurgical intervention, T 6 and T 7 laminectomy was performed. The cranial and caudal end of the right paramedian ventral dural defect was visualized and enlarged. Following extradural spinal cord mobilization by denticulate ligament transection, the spinal cord was finally released. The spinal cord was rotated and the ventral closure of the dural defect was performed by continuous suture. The patient recovered from surgery without additional deficits. The patient's postoperative gait, sensory, and motor function deficits improved, and further neurological deterioration was prevented. Conclusion: Since the first description of spinal cord herniation by Wortzman et al. in 1974, approximately 260 cases have been reported in the literature. In addition to other causes, intraspinal bone spur is a possible cause of spinal cord herniation.

14.
AME Case Rep ; 7: 28, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37492794

RESUMO

Background: Intradural disc herniations (IDH) are uncommon and can be found in the cervical spine. It is commonly associated with Brown-Sequard syndrome (BSS). The case report describes cervical spine magnetic resonance imaging (MRI) findings that assists in identifying IDH pre-operatively and discusses surgical management. Case Description: This is a case report regarding a 42-year-old obese male who developed atraumatic spontaneous bilateral upper extremity numbness, right upper extremity weakness and right lower extremity weakness. MRI showed a C6-7 herniated nucleus pulposus that focally protruded through the posterior longitudinal ligament with a beak-like projection similar to what has been described in previous reports. Clinical exam revealed an incomplete spinal cord injury (SCI) most consistent with BSS. He underwent anterior cervical discectomy and fusion at the level of C6-7. Intra-operatively, a disc fragment was found to be embedded in the dura. Three months post-operatively, the patient had persistent weakness in his right lower extremity but no longer had any bilateral upper extremity weakness. Conclusions: An anterior cervical decompression and fusion was performed shortly after the patient presented, with adequate neurological recovery after 3 months. Advanced imaging with an MRI could lead to the diagnosis of an IDH and surgical intervention via the anterior approach could facilitate removal of the disc and adequate dura repair.

15.
J Neurosurg Case Lessons ; 5(22)2023 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-37249142

RESUMO

BACKGROUND: Intraspinal juxta-facet cysts of the spine are known to predominate at the lumbar level and is relatively rare at the cervical level. Most cervical spinal lesions are found incidentally, but they sometimes cause myelopathy or radiculopathy in a chronic course. OBSERVATIONS: The authors present a rare case of hemorrhagic cervical juxta-facet cyst presenting with Brown-Séquard syndrome. An 86-year-old woman presented with acute-onset right hemiparesis following neck pain and was admitted to the local hospital. She was started on antithrombotic therapy with a suspected diagnosis of cerebral infarction, but quadriplegia progressed 2 days later. Cervical magnetic resonance imaging revealed an intraspinal mass at the C4-5 level and she was referred to the authors' hospital. Her neurological findings on admission revealed right Brown-Séquard syndrome. In emergency surgery, the mass was resected with a posterior approach. Pathological findings showed hemosiderin deposition and fibroblast proliferation, consistent with a juxta-facet cyst with intracystic hemorrhage. The patient recovered well and returned to an independent daily life. LESSONS: Rarely, juxta-facet cyst of the cervical spine can cause acute Brown-Séquard syndrome due to intraspinal hemorrhage. In a case of hemiparesis that develops following neck pain, hemorrhagic cervical juxta-facet cyst should be taken into consideration as a differentiation.

16.
J Spinal Cord Med ; 46(6): 986-990, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37010847

RESUMO

CONTEXT: Brown-Séquard Syndrome (BSS) is a rare neurological condition associated with Spinal Cord Injury (SCI). Hemisection of the spinal cord causes paralysis of the homolateral side, and thermoalgesic dysfunction on the opposite side. Cardiopulmonary and metabolic alterations have been reported. For all these patients, regular physical activity is highly recommended and functional electrical stimulation (FES) may be a good option, especially for those with paraplegia. However, to our knowledge, the effects of FES have primarily been studied in those with complete SCI and data regarding application and effects in patients with incomplete lesions (with sensory feedback) is lacking. The present case report therefore evaluated the feasibility and effectiveness of a 3-month FES-rowing program in a patient with BSS. METHODS: Knee extensor muscle strength and thickness, walking and rowing capacities as well as quality of life were evaluated before and after 3 months of FES-rowing (two sessions per week) in a 54 year old patient with BSS. RESULTS: The individual had excellent tolerance and adherence to the training protocol. All measured parameters were greatly improved after 3 months: on average, + 30% rowing capacity, + 26% walking capacity, + 24.5% isometric strength, + 21.9% quadriceps muscle thickness, + 34.5% quality of life. CONCLUSION: FES-rowing appears to be well tolerated and highly beneficial for a patient with incomplete SCI and could therefore be considered as an appealing exercise option for these patients.


Assuntos
Síndrome de Brown-Séquard , Terapia por Estimulação Elétrica , Traumatismos da Medula Espinal , Esportes Aquáticos , Humanos , Lactente , Traumatismos da Medula Espinal/complicações , Síndrome de Brown-Séquard/etiologia , Síndrome de Brown-Séquard/terapia , Terapia por Exercício/métodos , Qualidade de Vida , Terapia por Estimulação Elétrica/métodos , Exercício Físico/fisiologia , Estimulação Elétrica
17.
Int J Surg Case Rep ; 105: 108068, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37011461

RESUMO

INTRODUCTION AND IMPORTANCE: Brown-Séquard syndrome (BSS) is a rare syndrome consequence of interruption in the spinal cord following traumatic or non-traumatic injuries. Although, based on the previous literature, BSS has a good prognosis, some reports do not complete recovery following BSS. CASES PRESENTATION: In this current survey, we present two aggressive BSSs with complete recovery. One case involved a man aged 23 years without any underlying disease with multiple traumas with a knife who was transferred to the level 1 trauma center knife. Case two was a man 36 years with a gun shutting in C6 level. CLINICAL DISCUSSION: C5 total laminectomy and C4 and C6 partial laminectomy were done due to the sharp knife. Three months later, the patient achieved full recovery. After C6 total laminectomy in case 2, the patient was discharged without defect. CONCLUSION: Incomplete spinal cord injuries are challenging to diagnose and treat. Due to esophageal rupture and late debridement, full recovery was not expected. Despite neurological impairments, full recovery was achieved over three months in two cases. Also, many factors can aggravate the initial trauma in gunshot spine injury patients.

18.
J Neurosurg Case Lessons ; 4(23)2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36471576

RESUMO

BACKGROUND: Spinal hematomas are a rare entity with broad etiologies, which stem from idiopathic, tumor-related, and vascular malformation etiologies. Less common causes include traumatic blunt nonpenetrating spinal hematomas with very few cases being reported. In the present manuscript presents a case report and review of the literature of a rare traumatic entity of a cervical subarachnoid hematoma in association with Brown-Séquard syndrome in a patient on anticoagulants. Searches were performed on PubMed and Embase for specific terms related. OBSERVATIONS: A well-documented case of an 83-year-old female taking anticoagulants with traumatic cervical subarachnoid hematoma presenting as Brown-Séquard syndrome was reported. Six similar cases were identified, scrutinized, and analyzed in the literature review. LESSONS: Traumatic blunt nonpenetrating cervical spine subarachnoid hematomas are a rare entity that can happen more specifically in anticoagulant users and in patients with arthritic changes and stenosis of the spinal canal. Rapid neurological deterioration and severe disability warrant early aggressive surgical treatment. This report has the intention to record this case in the medical literature for registry purposes.

19.
Surg Neurol Int ; 13: 520, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36447879

RESUMO

Background: Nonmissile penetrating spine injury (NMPSI) represents a small percent of spinal cord injuries (SCIs), estimated at 0.8% in Western countries. Regarding the causes, an NMPSI injury caused by a screwdriver is rare. This study reports a case of a retained double-headed screwdriver in a 37-year-old man who sustained a stab injury to the back of the neck, leaving the patient with a C4 Brown-Sequard syndrome (BSS). We discuss the intricacies of the surgical management of such cases with a literature review. Methods: PubMed database was searched by the following combined formula of medical subjects headings, (MESH) terms, and keywords: (((SCIs [MeSH Terms]) OR (nmpsi [Other Term]) OR (nonmissile penetrating spinal injury [Other Term]) OR (nonmissile penetrating spinal injury [Other Term])) AND (BSS [MeSH Terms])) OR (BSS [MeSH Terms]). Results: A total of 338 results were found; 258 were case reports. After excluding nonrelated cases, 16 cases were found of BSS induced by spinal cord injury by a retained object. The male-to-female ratio in these cases is 11:5, and ages ranged from 11 to 72. The causes of spinal cord injury included screwdrivers in three cases, knives in five cases, and glass in three cases. The extracted data were analyzed. Conclusion: Screwdriver stabs causing cervical SCIs are extremely rare. This is the first case from Iraq where the assault device is retained in situ at the time of presentation. Such cases should be managed immediately to carefully withdraw the object under direct vision and prevent further neurological deterioration.

20.
Rinsho Shinkeigaku ; 62(10): 797-800, 2022 Oct 22.
Artigo em Japonês | MEDLINE | ID: mdl-36184414

RESUMO

A 50-year-old man was referred to our hospital with myelitis associated with a 10-months history of progressive muscle weakness in the left leg. Neurological examinations demonstrated diffuse muscle weakness of the left leg, touch hypoesthesia of the right leg, reduced pain sensation below the right nipple, left pyramidal sign, and urinary incontinence. On the basis of thoracic spinal MRI and thoracic CT myelography, revealing anterior displacement of the spinal cord and enlargement of the posterior subarachnoid space at the Th4 vertebral level, we diagnosed the patient as having idiopathic spinal cord herniation with incomplete Brown-Séquard syndrome. After microsurgical release of the spinal cord and subsequent covering of the anterior dural defect with an artificial dura mater, the symptoms improved without progression. Clinicians should consider spinal cord herniation as a cause of slowly progressive thoracic myelopathy with Brown-Séquard syndrome.


Assuntos
Síndrome de Brown-Séquard , Doenças da Medula Espinal , Masculino , Humanos , Pessoa de Meia-Idade , Síndrome de Brown-Séquard/diagnóstico por imagem , Síndrome de Brown-Séquard/etiologia , Debilidade Muscular/complicações , Hérnia/complicações , Hérnia/diagnóstico por imagem , Doenças da Medula Espinal/diagnóstico por imagem , Doenças da Medula Espinal/etiologia , Medula Espinal/diagnóstico por imagem , Imageamento por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA