Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.093
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Rev. Flum. Odontol. (Online) ; 1(66): 144-154, jan-abr.2025. ilus
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1570750

RESUMO

O avanço da tecnologia de digitalização de imagens e desenvolvimento de dispositivos de fresagem possibilitaram a otimização de diversos processos na Odontologia. O emprego do escaneamento intraoral e do sistema CAD-CAM (CAD - Computer Aided Design; CAM - Computer Aided Manufacturing) aprimorou a realização de reabilitações protéticas, permitindo a obtenção de peças de alta qualidade em tempo reduzido. O objetivo deste trabalho é relatar um caso de reabilitação de um incisivo central inferior a partir de escaneamento intraoral, com scanner Omnicam (DentsplySirona Charlotte, NC, EUA) e aplicação do sistema CAD-CAM.


The advancement of image digitization technology and the development of milling devices have made it possible to optimize various processes in Dentistry. The use of intraoral scanning and the CAD-CAM system (CAD - Computer Aided Design; CAM - Computer Aided Manufacturing) has improved the performance of prosthetic rehabilitations, allowing the obtaining of high quality parts in a reduced time. The objective of this work is to report a case of rehabilitation of a lower central incisor using intraoral scanning, with an Omnicam scanner (Dentsply Sirona) and application of the CAD-CAM system.

2.
Artigo em Inglês | MEDLINE | ID: mdl-39350584

RESUMO

INTRODUCTION: Implant-supported removable complete overdentures (IODs) are a common treatment in case of edentulism and malfunctioning of the conventional denture. Manufacturing IODs in a conventional way (C-IODs) is time-consuming, but in a digital workflow, this can be done in three sessions. Digitally produced IODs (3D-IODs) are also more advantageous than C-IODs because lost or broken 3D-IODs can be swiftly reproduced as the digital design is always available. PURPOSE: To prove in a non-inferiority study, with a margin of 0.3 point per Oral Health Impact Profile-20 (OHIP-20) question, that IODs made according to a fully digital workflow (3D-IODs), function as good as C-IODs with respect to patient-reported outcome measures (PROMs). MATERIALS AND METHODS: This randomized crossover study included 36 fully edentulous patients who showed extreme resorption of the maxillary alveolar process, making denture retention difficult. After a maxillary bone augmentation and the installation of 4-6 implants, each patient wore both types of IOD for 1 year each, with the order reversed in two subsets of patients. The 3D-IODs and C-IODs were fabricated in advance for both jaws (at least two mandibular implants were already present). The OHIP-20 survey was performed at baseline, after 1 year (before the IOD switch), and after 2 years to determine patient satisfaction scores using a visual analog scale (VAS). The general health status was assessed using the Short Form (SF-36) questionnaire. RESULTS: Regarding the PROMs, patients preferred the 3D-IOD: the improvement on the overall OHIP scale (0-4), expressed as a mean, was 0.26 points greater than for the C-IOD (p < 0.001). This applied also to the VAS scale (1-100) with an increase of 7.37 points (p < 0.001). Regarding the SF-36 scale, only for the item "emotional well-being," the 3D-IOD scored significantly better (p = 0.033). CONCLUSION: Compared with conventionally fabricated C-IODs, fully digitally produced 3D-IODs resulted in significantly higher OHIP-20 and satisfaction scores.

3.
Cureus ; 16(8): e68280, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39350816

RESUMO

INTRODUCTION: The hen's egg test on chorioallantoic membrane (HET-CAM) assay is a cost-effective and well-validated, non-animal-based ex vivo method for evaluating the irritant potential and eye toxicity of substances. A colloidal dispersion of a surfactant and a cosurfactant with a nanosize range is called a nanoemulsion (NE), which is formed by mixing immiscible liquids and stabilized by surfactants. Patients with glaucoma are commonly prescribed Brimonidine (BR), an alpha-2 adrenergic agonist, to lower their intraocular pressure. MATERIALS AND METHODS: In this study, surfactant-cosurfactant blends were prepared by mixing Tween 80 (surfactant) and propylene glycol (cosurfactant) in a 4:1(v/v) ratio. Triacetin served as the oil phase, while deionized water was used as the aqueous phase. Using the drop method, a range of NE formulations (F1, F2, F3, FB1, FB2, and FB3) were developed and subsequently evaluated for their potential to irritate, and then the results were compared to those of a commercially available BR eye drop formulation. RESULTS: According to the average cumulative HET-CAM test scores (IS), from excipients, propylene glycol caused moderate irritation by causing slight damage to blood vessels. The formulations FB1 and F1 were found to have the highest level of irritation among other formulations in the investigation, recording 1.05 ±0.07 and 1.2 ±0.10, respectively. All other NE formulations exhibited non-irritating potential, as confirmed by the HET-CAM test, and were comparable to the marketed BR eye drop formulation. CONCLUSION: The NE formulations created for BR were determined to be safe and non-irritating. The findings indicate that the prepared NE could be a beneficial solution for addressing problems with conventional eye drops and delivering BR effectively to the eyes.

4.
J Histotechnol ; : 1-10, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39351917

RESUMO

Gliomas are malignant tumors of neuronal support cells within the central nervous system (CNS) and are characterized by poor overall prognoses and limited treatment options due to their infiltrative growth patterns. The neural tumor microenvironment, composed of benign neurons, neuroglia, endothelial cells, and intravascular white blood cells, is a target-rich site for potential chemotherapeutic agents. This study assessed cell proliferation rates, white blood cell components, and a limited number of nuclear, cytoplasmic, and membrane markers using immunohistochemistry (IHC) assays on formalin-fixed and paraffin-embedded benign and glial tumor tissue samples from the CNS. It was observed that glioma tissues had increased rates of glial cell proliferation and significant increases in the number of observed T-lymphocytes and granulocytes but decreased expression of markers Somatostatin receptor 2 (SSTR2), L1 cell adhesion molecule (L1CAM), and GATA binding protein 3 (GATA3) when compared to benign tissue samples. Understanding the lack of protein expression and population expansion potential of the glioma microenvironment in greater detail could help identify valuable therapeutic target combinations for future treatments.

5.
BMC Oral Health ; 24(1): 1168, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39354422

RESUMO

BACKGROUND: Occlusal veneer had been evaluated for mechanical properties using lithium disillicate. However, studies evaluating the mechanical properties of occlusal veneer with different preparation designs and ceramic materials are lacking. So, this in vitro study aimed to evaluate the fracture resistance of occlusal veneers with two designs fabricated from two different ceramic materials. MATERIAL AND METHODS: Fourty mandibular third molars were distributed to 2 groups (n = 20) according to preparation design: group (O) anatomical occlusal reduction and group (OA) anatomical occlusal and 1 mm axial reduction. Each group was additionally subdivided into two subgroups (n = 10) according to ceramic materials; in subgroup X, lithium disilicate (e.max CAD, Ivoclar AG, Schaan, Liechtenstein) was used, and in subgroup S, zirconia-reinforced lithium silicate (ZLS) (Vita Suprinity, VitaZahnfabrik, Bad Säckingen, Germany) was used. All specimens were cemented with a light-cure resin cement (Choice 2, Bisco, Schaumburg, USA). 5000 thermocycles were applied to all specimens with both temperatures of 5 °C and 55 °C in two water baths; the dwell time was 30s at each bath, and the transfer time was 10s. Then all specimens were subjected to a fatigue simulation under dynamic loading of 200 N for 250,000 cycles. A universal testing machine (5500R/1123, Instron, Norwood, USA) was used to evaluate the fracture strength with a crosshead speed of 1 mm/min. All data were analyzed statistically by using a two-way ANOVA, and for some violations of assumptions, these results were compared with those obtained by the nonparametric test (Scheirer Ray Hare) (α = 0.05). RESULTS: A statistically significantly higher fracture resistance in the 'OA' (3389 N) compared to the 'O' (2787 N) group regardless of the ceramic material (P < .001) and a statistically significantly higher fracture resistance in the 'X' (3295 N) compared to the 'S' (2881 N) regardless of the preparation design (P = .015). CONCLUSIONS: For occlusal veneers, all preparation designs and materials (such as Vita Suprinity and e.max CAD) had clinically acceptable fracture resistance values that were greater than the maximal biting forces. On the other hand, the e.max CAD with occlusal veneer, including axial reduction design, demonstrated the maximum fracture resistance value. Finally, no relationship between fracture strength and mode of failure was found.


Assuntos
Desenho Assistido por Computador , Porcelana Dentária , Análise do Estresse Dentário , Facetas Dentárias , Humanos , Porcelana Dentária/química , Técnicas In Vitro , Fraturas dos Dentes/prevenção & controle , Zircônio/química , Cerâmica/química , Teste de Materiais , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Dente Molar , Dente Serotino
6.
Prenat Diagn ; 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39218781

RESUMO

Recent advances in gene therapy, particularly for single-gene disorders (SGDs), have led to significant progress in developing innovative precision medicine approaches that hold promise for treating conditions such as primary hydrocephalus (CH), which is characterized by increased cerebrospinal fluid (CSF) volumes and cerebral ventricular dilation as a result of impaired brain development, often due to genetic causes. CH is a significant contributor to childhood morbidity and mortality and a driver of healthcare costs. In many cases, prenatal ultrasound can readily identify ventriculomegaly as early as 14-20 weeks of gestation, with severe cases showing poor neurodevelopmental outcomes. Postnatal surgical approaches, such as ventriculoperitoneal shunts, do not address the underlying genetic causes, have high complication rates, and result in a marginal improvement of neurocognitive deficits. Prenatal somatic cell gene therapy (PSCGT) promises a novel approach to conditions such as CH by targeting genetic mutations in utero, potentially improving long-term outcomes. To better understand the pathophysiology, genetic basis, and molecular pathomechanisms of CH, we conducted a scoping review of the literature that identified over 160 published genes linked to CH. Mutations in L1CAM, TRIM71, MPDZ, and CCDC88C play a critical role in neural stem cell development, subventricular zone architecture, and the maintenance of the neural stem cell niche, driving the development of CH. Early prenatal interventions targeting these genes could curb the development of the expected CH phenotype, improve neurodevelopmental outcomes, and possibly limit the need for surgical approaches. However, further research is needed to establish robust genotype-phenotype correlations and develop safe and effective PSCGT strategies for CH.

7.
Skin Res Technol ; 30(9): e70040, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39221858

RESUMO

BACKGROUND: Skin cancer is one of the highly occurring diseases in human life. Early detection and treatment are the prime and necessary points to reduce the malignancy of infections. Deep learning techniques are supplementary tools to assist clinical experts in detecting and localizing skin lesions. Vision transformers (ViT) based on image segmentation classification using multiple classes provide fairly accurate detection and are gaining more popularity due to legitimate multiclass prediction capabilities. MATERIALS AND METHODS: In this research, we propose a new ViT Gradient-Weighted Class Activation Mapping (GradCAM) based architecture named ViT-GradCAM for detecting and classifying skin lesions by spreading ratio on the lesion's surface area. The proposed system is trained and validated using a HAM 10000 dataset by studying seven skin lesions. The database comprises 10 015 dermatoscopic images of varied sizes. The data preprocessing and data augmentation techniques are applied to overcome the class imbalance issues and improve the model's performance. RESULT: The proposed algorithm is based on ViT models that classify the dermatoscopic images into seven classes with an accuracy of 97.28%, precision of 98.51, recall of 95.2%, and an F1 score of 94.6, respectively. The proposed ViT-GradCAM obtains better and more accurate detection and classification than other state-of-the-art deep learning-based skin lesion detection models. The architecture of ViT-GradCAM is extensively visualized to highlight the actual pixels in essential regions associated with skin-specific pathologies. CONCLUSION: This research proposes an alternate solution to overcome the challenges of detecting and classifying skin lesions using ViTs and GradCAM, which play a significant role in detecting and classifying skin lesions accurately rather than relying solely on deep learning models.


Assuntos
Algoritmos , Aprendizado Profundo , Dermoscopia , Neoplasias Cutâneas , Humanos , Dermoscopia/métodos , Neoplasias Cutâneas/diagnóstico por imagem , Neoplasias Cutâneas/classificação , Neoplasias Cutâneas/patologia , Interpretação de Imagem Assistida por Computador/métodos , Bases de Dados Factuais , Pele/diagnóstico por imagem , Pele/patologia
8.
J Esthet Restor Dent ; 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39228138

RESUMO

OBJECTIVE: This in vitro study aimed to evaluate the effectiveness of a printed surgical guide for root sectioning in the socket-shield technique. MATERIALS AND METHODS: A typodont model of the maxilla with augmented filler was used for the upper right central incisor, and CBCT images were obtained. Two types of vertical root sectioning guides were tested: one with a buccal sleeve (Group A, n = 10) and another with a buccal orientation slit (Group B, n = 10). Control group (n = 10) performed freehand cuts on printed models. After crown cutting with diamond burs, root sectioning was conducted using an ultrasonic tip with the guides. Mean and standard deviation were calculated for the remaining root length, width, and volume. Data were analyzed using the Kruskal-Wallis test and Dunn's post hoc test. RESULTS: Statistical analysis showed significant differences in root width between the control group (2.0 mm) and both Groups A (2.655 mm; p < 0.0001) and B (2.460 mm; p < 0.0001). Group B (5.585 mm) also showed a significant difference in root remnant compared with the control (13.880 mm; p < 0.0043). Groups A and B did not differ significantly from each other. CONCLUSIONS: The socket shield technique is safe and effective, this study aimed to add improvements through the introduction of surgical guides, facilitating the root section, which is the critical phase so that the parameters that are requisite for success are achieved in terms of width, length, and volume of the root remnant. Both guided techniques effectively facilitated root sectioning, maintaining satisfactory root thickness and length. CLINICAL SIGNIFICANCE: Sectioning the root is challenging for the correct angulation to remove the palatal portion in the socket shield technique. Therefore, modifying this technique with the use of the presented guides, it is possible to prevent damage to the soft tissues and to plan the surgery with the help of cone beam computed tomography (CBCT) scans to remove the root apex and maintain the root remnant with a thickness greater than 1.5 mm, making the socket-shield technique more predictable.

9.
J Prosthodont ; 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39233435

RESUMO

PURPOSE: To analyze the microstructural and mechanical properties of various commercial trademarks of lithium disilicate ceramics for CAD-CAM systems. MATERIALS AND METHODS: Specimens of different lithium disilicate ceramics were obtained and randomized into 5 groups (n = 14): EM: e.max CAD; RT: Rosetta SM; EV: Evolith; PM: Smile-Lithium CAD; and, HS: HaHaSmile. The microstructural analysis was performed by X-ray diffraction (XRD) and scanning electron microscopy (SEM); for flexural strength, the three-point bending flexure test was used. XRD and SEM data were qualitatively evaluated. Data from flexural strength were assessed with one-way ANOVA test (α = 0.05) and Weibull analysis. RESULTS: High peaks corresponding to the lithium metasilicate and lithium disilicate pattern with similar intensities were observed in all ceramics in the XRD analysis. SEM images showed similar patterns of crystalline structure in the EM and RT ceramics, while the other three groups presented different crystal morphologies than the previous ones and were similar to each other. No differences were found in flexural strength among the groups (p = 0.28). CONCLUSIONS: The CAD-CAM lithium disilicate ceramics showed comparable crystalline intensities. The microstructure of the EM and RT ceramics were different from the other groups. Flexural strength was similar among all ceramics.

10.
J Prosthodont ; 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39233444

RESUMO

PURPOSE: This systematic review aimed to provide comprehensive insights on the accuracy, fit, and mechanical characteristics of implant-supported computer-aided design and computer-aided manufacturing (CAD-CAM) prostheses, with a focus on milled and 3D-printed approaches. METHODS: The research question focused on implant-supported dental prostheses, comparing different manufacturing techniques (conventional, milled, and 3D-printed) to determine the different factors affecting the mechanical properties and fit of the CAD-CAM implant-supported prosthesis. The eligibility criteria encompassed studies involving implant-supported restorations, clear reporting of manufacturing techniques, and English-language publications from the last decade. The search was conducted across three main databases, MEDLINE, Scopus, and Web of Science in September 2023. Publication details, study characteristics, and methodological details of each included study were described. RESULTS: Of the initial 1964 articles, 581 met the inclusion criteria, and 104 studies were included in the final qualitative analysis. The majority of studies were conducted in the United States, Turkey, and Brazil. Fourteen studies evaluated accuracy parameters, while four studies focused on mechanical characteristics. The studies revealed variability in mechanical properties and marginal and internal fit, with fabrication methods impacting the structural integrity and stress distribution of the prostheses. CONCLUSIONS: The findings suggest that digital manufacturing workflows, both milling and 3D printing, yield acceptable properties for implant-supported restorations with minimal variations in fit and accuracy. Notably, 3D printing and hybrid techniques demonstrate advantages in specific aspects like marginal fit and stress distribution. However, the milled prosthesis provided superior results in flexural strength and fracture resistance compared to conventional methods. Further research is needed to confirm these findings in clinical settings.

11.
Trials ; 25(1): 589, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39238023

RESUMO

BACKGROUND: Nowadays, stabilization splints for the management of bruxism and temporomandibular disorders (TMD) can be produced utilizing a digital workflow comprising a digital impression of the teeth, digital splint design, and computer-aided manufacturing of the splints. The latter is usually a milling process, however, more recently 3D printing gained popularity due to its better cost and time efficiency. It remains unknown whether 3D printed stabilization splints are inferior to milled splints regarding clinical outcomes. METHODS: This clinical trial assesses the non-inferiority of 3D printed occlusal splints compared to milled occlusal splints in a monocentric prospective randomized single-blinded crossover trial with two cohorts. One cohort includes 20 participants with bruxism, the other 20 participants with pain-related TMD, i.e., myalgia, myofascial pain, or arthralgia of the jaw muscles/the temporomandibular joint(s) diagnosed according to the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD). Michigan-type stabilization splints are fabricated in a digital workflow by milling or 3D printing using CE-marked materials within their intended purpose. The participants wear a milled and a 3D printed splint in a randomized order for 3 months each, with follow-up visits after 2 weeks and 3 months. Investigated outcome parameters are oral health-related quality of life (OHRQoL) evaluated by the Oral Health Impact Profile (OHIP-G14), participant satisfaction as rated on a visual analog scale, therapeutic efficacy, and technical result of the splints. In this context, therapeutic efficacy means antagonist wear and-in the TMD group-reduction of pain/disability assessed by the Graded Chronic Pain Scale (GCPS v2.0) and clinical assessment following the DC/TMD standard, while technical outcome measures splint fit, wear and fracture rate. DISCUSSION: The trial will provide important information on the clinical outcome of 3D printed stabilization splints in comparison to milled splints and will, therefore, enable an evidence-based decision in favor of or against a manufacturing process. This, in turn, will guarantee for a maximum of the patient's OHRQoL during splint therapy, therapeutic efficacy, and longevity of the splints. TRIAL REGISTRATION: German Clinical Trials Register (DRKS) DRKS00033904. Registered on March 15, 2024.


Assuntos
Bruxismo , Estudos Cross-Over , Placas Oclusais , Impressão Tridimensional , Transtornos da Articulação Temporomandibular , Humanos , Transtornos da Articulação Temporomandibular/terapia , Transtornos da Articulação Temporomandibular/diagnóstico , Método Simples-Cego , Estudos Prospectivos , Resultado do Tratamento , Bruxismo/terapia , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos de Equivalência como Asunto , Medição da Dor , Adulto
12.
Chin J Dent Res ; 27(3): 253-262, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39221986

RESUMO

OBJECTIVE: To examine the increased use of chairside CAD/CAM among Chinese dental practitioners, and to explore the existing barriers influencing its further application and satisfaction levels. METHODS: A semi-structured questionnaire was developed to gather respondents' demographic information, as well as their experiences and behaviours regarding the implementation of chairside CAD/CAM. A specialised web-based survey system and WeChat were used to display and distribute the final questionnaire. Then, the data were analysed with Chi-square tests and regression analyses to determine the effects of various demographic variables on chairside CAD/ CAM applications. RESULTS: A total of 1,969 questionnaire responses were included in the analyses. Chairside CAD/ CAM systems were used by 36.9% of participants, with a higher usage rate observed among prosthodontists (60.0%) and dental practitioners holding a PhD degree (57.7%). Chairside CAD/ CAM-fabricated prostheses were most commonly used in the posterior maxilla (83.3%) and mandible (86.0%), followed by the anterior maxilla and mandible (63.8% and 48.6%, respectively). Major barriers to further application included high initial investment, frequent updates of equipment and software programs, and a lack of expertise in chairside CAD/CAM usage. CONCLUSION: Most dental practitioners did not use chairside CAD/CAM systems. The application rate was significantly influenced by sex, location, educational background, department and type of healthcare facility. Chairside CAD/CAM users showed limited satisfaction with the aesthetic performance of the fabricated prostheses. To improve the popularity of chairside CAD/CAM systems, especially among dental practitioners lacking advanced academic degrees, it is highly advisable to optimise CAD software programs and offer comprehensive training opportunities.


Assuntos
Desenho Assistido por Computador , Odontólogos , Humanos , Masculino , Feminino , Estudos Transversais , Adulto , Inquéritos e Questionários , Pessoa de Meia-Idade , China , Planejamento de Prótese Dentária , Adulto Jovem , População do Leste Asiático
13.
BMC Oral Health ; 24(1): 1033, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39227885

RESUMO

BACKGROUND: The accuracy of intraoral scanning is critical for computer-aided design/computer-aided manufacturing workflows in dentistry. However, data regarding the scanning accuracy of various adjacent restorative materials and intraoral scanners are lacking. This in vitro study aimed to evaluate the effect of adjacent restorative material type and CEREC's intraoral scanners on the accuracy of intraoral digital impressions for inlay cavities. METHODS: The artificial tooth was prepared with an occlusal cavity depth of 2 mm, a proximal box width at the gingival floor of 1.5 mm, and an equi-gingival margin extended disto-occlusally at the transition line angle on both the lingual and buccal sides for an inlay restoration. The adjacent teeth were veneered with crowns made of gold and zirconia, and an artificial tooth (resin) was utilized as the control group. The inlay cavity and adjacent teeth (Gold, Zirconia, and resin) were scanned 10 times using Chairside Economical Restoration of Esthetic Ceramics (CEREC) Primescan (PS), Omnicam (OC), and Bluecam (BC). A reference scan was obtained using a laboratory scanner (3-shape E3). Scanning was performed according to the manufacturer's instructions, including powder application for the BC group. Standard tesselation language files were analyzed using a three-dimensional analysis software program. Experimental data were analyzed using a two-way analysis of variance and the Tukey's post-hoc comparison test. RESULTS: The restorative materials of the adjacent teeth significantly affected the accuracy of the intraoral digital impressions (p < .05). The zirconia group exhibited the highest trueness deviation, followed by the resin and gold groups, with each demonstrating a statistically significant difference (p < .05). The resin group demonstrated the highest maximum positive deviation and deviation in precision. Gold exhibited the lowest average deviation value for trueness compared with those of the other adjacent restorative materials. Intraoral scanner type significantly influenced the trueness and precision of the scan data (p < .05). The average deviation of trueness according to the intraoral scanner type increased in the following order: BC > PS > OC. The average deviation in precision increased in the following order: PS>OC>BC (p < .05). CONCLUSION: The restorative materials of the adjacent tooth and the type of intraoral scanner affect the accuracy of the intraoral digital impression. The trueness of the digital images of the BC group, obtained by spraying the powder, was comparable to that of the PS group. Among the adjacent restorative materials, zirconia exhibited the lowest trueness. In contrast, PS demonstrated the highest precision among the intraoral scanners, while resin displayed the lowest precision among the adjacent restorative materials.


Assuntos
Desenho Assistido por Computador , Restaurações Intracoronárias , Zircônio , Humanos , Técnica de Moldagem Odontológica , Técnicas In Vitro , Materiais Dentários , Coroas , Cerâmica , Planejamento de Prótese Dentária/métodos , Restauração Dentária Permanente/métodos
14.
Semin Arthritis Rheum ; 69: 152539, 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39241663

RESUMO

OBJECTIVES: To determine the association between baseline cam morphology and self-reported hip pain assessed at annual visits over a 10-year follow-up period stratified by biological sex. The secondary aim was to study the association between the magnitude of cam morphology and the severity of pain in symptomatic hips. METHODS: The nationwide prospective Cohort Hip and Cohort Knee (CHECK) study includes 1,002 participants aged 45-65 years. Logistic regression with generalized estimating equations were used to determine the strength of the associations between (1) baseline cam morphology (both alpha angle ≥60° and as a continuous measure) and the presence of hip pain at 10 annual follow-up visits and (2) the alpha angle (continuous) and the severity of pain as classified by Numerical Rating Scale at 5-,8-, 9-, and 10-years. The results are expressed as odds ratios (OR), adjusted for age, biological sex (only in the sex-combined group), body mass index, and follow-up Kellgren and Lawrence grade. RESULTS: In total, 1,658 hips were included at baseline (1,335 female hips (79.2%)). The prevalence of cam morphology was 11.1% among all hips (29.1% in males; 6.4% in females). No association was found between cam morphology at baseline and the presence of hip pain at any follow-up in the female or sex-combined group. In males, only at 5-year follow-up, significant adjusted ORs were observed for the presence of cam morphology (1.77 (95%CI: 1.01-3.09)) and the alpha angle (1.02 (95%CI:1.00-1.04)). No evidence of associations was found between the alpha angle and the severity of hip pain in any of three groups. CONCLUSION: Within this study, no consistent associations were found between cam morphology and hip pain at multiple follow-ups. There might be a weak relationship between cam morphology and hip pain in males, while no such relation was found in females. We did not identify an association between the alpha angle and severity of hip pain.

15.
Artigo em Inglês | MEDLINE | ID: mdl-39242267

RESUMO

This prospective study aimed to compare ultra-high molecular weight polyethylene (UHMWPE) with polyetheretherketone (PEEK) in computer-designed patient-specific implants (PSIs) for cranial defect reconstruction, in terms of complications and aesthetic outcomes. Primary or secondary cranioplasty-eligible patients were included, while patients with active infection or hydrocephalus, or unfit for general anesthesia, were excluded from the study. All the implants were designed and fabricated by the same maxillofacial surgeon using CAD/CAM technology. UHMWPE PSIs were used in group 1 and PEEK PSIs in group 2. Technically, UHMWPE could be milled to a thinner margin thickness than PEEK, which resulted in better handling properties and a smoother end finish. All patients were evaluated over a period of 6 months in terms of overall complications or implant failure as the primary outcome, according to Clavien-Dindo (CVD) grading, and cosmetic satisfaction with the aesthetic results, using a Likert scale, as the secondary outcome. In total, 22 cranioplasty patients were included, with a mean age of 30.8 years (SD = 16.3). Across both groups, 17 patients (77.3%) did not develop postoperative complications. These occurred in three patients in group 1 (CVD grade I, II, and IIIb) (27.3%) and in two patients in group 2 (CVD grade II, IIIa, and IIIb) (18.2%), with no statistical difference (p = 0.6). None of the cases in both groups developed any clinical or radiographic signs of infection, or suffered implant failure. The mean satisfaction score was 4.8 in group 1 and 4.5 in group 2 (SD = 0.6). The difference in satisfaction scores between the two was not statistically significant (p = 0.23). Although UHMWPEE was comparable to PEEK in terms of overall complication rates and cosmesis after craniectomy, UHMWPEE as a material exhibited greater resiliency in technically challenging cases with large, complex/midline-crossing designs, previously fitted meshes, or single-stage resection-reconstruction, allowing better marginal adaptation.

16.
BMC Med Imaging ; 24(1): 230, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39223507

RESUMO

Breast cancer is a leading cause of mortality among women globally, necessitating precise classification of breast ultrasound images for early diagnosis and treatment. Traditional methods using CNN architectures such as VGG, ResNet, and DenseNet, though somewhat effective, often struggle with class imbalances and subtle texture variations, leading to reduced accuracy for minority classes such as malignant tumors. To address these issues, we propose a methodology that leverages EfficientNet-B7, a scalable CNN architecture, combined with advanced data augmentation techniques to enhance minority class representation and improve model robustness. Our approach involves fine-tuning EfficientNet-B7 on the BUSI dataset, implementing RandomHorizontalFlip, RandomRotation, and ColorJitter to balance the dataset and improve model robustness. The training process includes early stopping to prevent overfitting and optimize performance metrics. Additionally, we integrate Explainable AI (XAI) techniques, such as Grad-CAM, to enhance the interpretability and transparency of the model's predictions, providing visual and quantitative insights into the features and regions of ultrasound images influencing classification outcomes. Our model achieves a classification accuracy of 99.14%, significantly outperforming existing CNN-based approaches in breast ultrasound image classification. The incorporation of XAI techniques enhances our understanding of the model's decision-making process, thereby increasing its reliability and facilitating clinical adoption. This comprehensive framework offers a robust and interpretable tool for the early detection and diagnosis of breast cancer, advancing the capabilities of automated diagnostic systems and supporting clinical decision-making processes.


Assuntos
Neoplasias da Mama , Ultrassonografia Mamária , Humanos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Ultrassonografia Mamária/métodos , Interpretação de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Inteligência Artificial
17.
Cancers (Basel) ; 16(17)2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39272798

RESUMO

The microtubule-disrupting agent 2-methoxyestradiol (2-ME) displays anti-tumor and anti-angiogenic properties, but its clinical development is halted due to poor pharmacokinetics. We therefore designed two 2-ME analogs in silico-an ESE-15-one and an ESE-16 one-with improved pharmacological properties. We investigated the effects of these compounds on the cytoskeleton in vitro, and their anti-angiogenic and anti-metastatic properties in ovo. Time-lapse fluorescent microscopy revealed that sub-lethal doses of the compounds disrupted microtubule dynamics. Phalloidin fluorescent staining of treated cervical (HeLa), metastatic breast (MDA-MB-231) cancer, and human umbilical vein endothelial cells (HUVECs) displayed thickened, stabilized actin stress fibers after 2 h, which rearranged into a peripheral radial pattern by 24 h. Cofilin phosphorylation and phosphorylated ezrin/radixin/moesin complexes appeared to regulate this actin response. These signaling pathways overlap with anti-angiogenic, extra-cellular communication and adhesion pathways. Sub-lethal concentrations of the compounds retarded both cellular migration and invasion. Anti-angiogenic and extra-cellular matrix signaling was evident with TIMP2 and P-VEGF receptor-2 upregulation. ESE-15-one and ESE-16 exhibited anti-tumor and anti-metastatic properties in vivo, using the chick chorioallantoic membrane assay. In conclusion, the sulfamoylated 2-ME analogs displayed promising anti-tumor, anti-metastatic, and anti-angiogenic properties. Future studies will assess the compounds for myeloproliferative effects, as seen in clinical applications of other drugs in this class.

18.
Plants (Basel) ; 13(17)2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39274013

RESUMO

Most of the aquatic vegetation produces organic substances via the C3 photosynthetic pathway (mosses, isoetids-Lobelia dortmanna L., Luronium natans (L.) Raf., and vascular plants) or Crassulacean acid metabolism (CAM, e.g., Littorella uniflora (L.) Asch. and Isoëtes lacustris L.) or by their ability to use HCO3- via carbon concentration mechanisms (CCMs-some elodeids and charophytes). Differentiating these predominant photosynthetic pathways in aquatic vegetation based on their organic matter (OM) carbon stable isotopes (δ13CORG) is a complex task, in contrast to terrestrial plants. This study investigates the OM deposition, characterized by δ13CORG values in 10 macrophyte species with different photosynthetic pathways (C3, CAM, and CCM) collected from 14 softwater Lobelia lakes in northern Poland. The higher δ13CORG values distinguish the CCM group, indicating their use of 13C-enriched HCO3¯ in photosynthesis. CAM species show slightly higher δ13CORG values than C3, particularly in lower pH lakes. Principal component analysis of isotopic and environmental data did not yield clear distinctions by the groups, but still, they significantly differ in light of analyzed parameters and isotopic signals (PRMANOVA = 5.08, p < 0.01; K-W H = 27.01, p < 0.001). The first two PCA dimensions showed that the water pH and Ca2+ concentration positively influenced δ13C values. The influence of light conditions on δ13CORG values revealed by third PCA components seems to also be important. In summary, northern Polish Lobelia lakes serve as a key differentiation point between vegetation employing CCMs and those relying on C3/CAM photosynthesis without HCO3- utilization, providing insights into transitions in plant communities within these ecosystems.

19.
J Clin Med ; 13(17)2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39274470

RESUMO

Background: Treatment methods for mandibular head fractures are controversial, although effective techniques for open reduction and rigid fixation (ORIF) have been known since the late 1990s. Notably, some forms of posttraumatic comminution of the mandibular head can be reduced or fixed. Methods: This study presents a personalized treatment to cure patients with nonreduced comminuted fractures of the mandibular head: total temporomandibular joint alloplastic replacement (18 patients). The reference group included patients who underwent ORIF (11 patients). Results: Personalized alloplastic joint replacements resulted in a more stable mandibular ramus after three months compared with ORIF. Conclusions: The authors recommend not performing osteosynthesis when the height of the mandibular ramus cannot be stably restored or when periosteal elevation from most of the mandibular head is necessary for ORIF. Personalized TMJ replacement should be considered in such patients. Personalized medicine allows patients to maintain a normal mandibular ramus height for a long period of time.

20.
J Clin Med ; 13(17)2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39274484

RESUMO

Background/Objectives: The purpose of this study was to analyze relevant areas in acute-stage fluorescein angiography (FA) images, predicting the long-term visual prognosis of branch retinal vein occlusion (BRVO) based on gradient-weighted class activation mapping (Grad-CAM). Methods: This retrospective observational study included 136 eyes with BRVO that were followed up for more than a year post-FA. Cropped grayscale images centered on the fovea (200 × 200 pixels) were manually pre-processed from early-phase FA at the acute phase. Pairs of the cropped FA images and the best-corrected visual acuity (BCVA) in remission at least one year post-FA were used to train a 38-layer ResNet with five-fold cross-validation. Correlations between the ResNet-predicted and true (actually measured) logMAR BCVAs in remission, and between the foveal avascular zone (FAZ) area measured by ImageJ (version 1.52r) from FA images and true logMAR BCVA in remission were evaluated. The heat maps generated by Grad-CAM were evaluated to determine which areas were consumed as computational resources for BCVA prediction. Results: The correlation coefficient between the predicted and true logMAR BCVAs in remission was 0.47, and that between the acute-stage FAZ area and true logMAR BCVA in remission was 0.42 (p < 0.0001 for both). The Grad-CAM-generated heat maps showed that retinal vessels adjacent to the FAZ and the FAZ per se had high selectivity (95.7% and 62.2%, respectively). Conclusions: The Grad-CAM-based analysis demonstrated FAZ-neighboring vessels as the most relevant predictor for the long-term visual prognosis of BRVO.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA