1.
Toxics ; 12(8)2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39195646

RESUMO

Firefighters are exposed to hazardous chemicals at fire scenes, including polycyclic aromatic hydrocarbons (PAHs) among many others, which pose significant health risks. Current laundering practices are ineffective at removing persistent contaminants from turnout gear, necessitating further research to optimize cleaning methods. This study explores the impact of presoaking prior to the laundering process and the factors that can affect its effectiveness, including the presoaking duration and detergent concentration, in PAH removal when laundering. For this, contaminated fabric swatches were subjected to various presoaking durations (1, 3, and 12 h) and detergent concentrations (99:1 and 90:10 water-to-detergent ratios) before undergoing bench-scale washing. The cleaning efficacy was assessed for 16 PAH compounds, including both low-molecular-weight (LMW) PAHs and high-molecular-weight (HMW) PAHs. Moreover, the removal mechanisms of PAHs from turnout gear were fundamentally explained using partition coefficients and standard affinities with different parameters during washing. The results demonstrate that 3 h and 12 h of presoaking lead to 2.8 and 4.3 times greater HMW PAH removal, respectively. After 12 h of presoaking in a 90:10 water-to-detergent ratio, 97% of the LMW PAHs and 78% of the HMW PAHs were removed, compared to only an 11% removal of the HMW PAHs with a 99:1 ratio. Additionally, direct washing with a 90:10 ratio achieved comparable efficacy to that of presoaking with the same water-to-detergent ratio, indicating the crucial role of detergent concentration during laundering. These findings offer valuable insights for optimizing firefighter safety practices, emphasizing the role of presoaking and the appropriate methods to perform presoaking to mitigate firefighters' occupational exposure risks to toxic substances and ensure gear reliability.

2.
J Conserv Dent Endod ; 27(5): 498-502, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38939537

RESUMO

Aim: To evaluate cleaning efficacy and debris extrusion of supplementary file systems XP Endo Finisher (XPEF) and XP Endo Finisher R (XPEFR) in endodontic retreatment. Materials and Methods: Thirty single-rooted teeth with single canals were selected, canal preparation done till file #30 6% and obturation completed using lateral condensation technique with AH Plus sealer. The samples were stored at 37°C in a 100% humidity incubator for 7 days. The samples were distributed across the three groups according to the method of retreatment (n = 10): Group I: Neo Endo retreatment (NER) files, Group II: NER files + XPEF, and Group III: NER files + XPEFR. Removal of gutta percha using each file system according to the distributed groups was performed. The extruded debris was collected in an Eppendorf tube, dried in a hot air oven, and weighed. Teeth were sliced longitudinally using carborundum discs. Coronal, middle, and apical thirds were assessed for cleaning efficacy under a stereomicroscope. Results were tabulated and subjected to the statistical analysis using the Kruskal-Wallis H-test followed by post hoc turkey HSD test. All statistical tests were carried out at significance level P < 0.05. Results: It was seen that Group II (NER files + XPEF) exhibited better cleaning efficacy than Group III (NER files + XPEFR), although the results were not statistically significant. Greater debris extrusion was seen with Group III when compared to Group II. Conclusion: Supplementary files XPEF/XPEFR enhance the cleaning efficacy in endodontic retreatment, but the debris extrusion of XPEFR is more than XPEF.

3.
BMC Oral Health ; 24(1): 404, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38553668

RESUMO

BACKGROUND: Up to date, interdental brushes (IDB) are the first choice for interdental cleaning because of their cleaning efficacy. Cylindrical ones must be selected individually according to the size/morphology of the interdental area (IDR), whereas conical ones cover a larger variability of IDR. However, there is a trend on the part of patients towards interdental rubber picks (IRP) which are in general conically shaped, and which seem to be linked with lower cleaning efficacy. A new IRP with an Archimedes´ screw design was developed to overcome this limitation. Therefore, the in vitro study aimed to measure the experimental cleaning efficacy (ECE) and force (ECF) during interdental use of IDBs versus the new IRP type. METHODS: Three IRPs with different tapers (PHB angled: 0.039, PHB straight S: 0.027, Vitis straight M: 0.045; all Flexipicks, Dentaid, Cerdanyola del Vallès, Spain) were compared to one IDB (Interprox micro PHD 0.9, Dentaid, Cerdanyola del Vallès, Spain). IDR were reproduced by a 3D-printer (Form2, Formlabs Sommerville, MA, USA) according to human teeth and matched to equivalent pairs (isosceles triangle, concave, convex) in three different diameters (1.0 mm,1.1 mm,1.3 mm). Covered with simulated biofilm, pre-/ post-brushing situations of IDR (standardized, computer-aided ten cycles) were photographed and quantified by digital image subtraction to calculate ECE [%]. ECF were registered with a load cell [N]. Statistically significant differences were detected using the Mann-Whitney-U-test and the Kruskal-Wallis-test with Bonferroni correction for multiple testing. RESULTS: Overall, the ECE (mean ± SD) was higher for IDB micro 0.9 (45.95 ± 11.34%, p < 0.001) compared to all IRPs (PHB angled: 25.37 ± 15.29%; PHB straight: 22.28 ± 16.75%; Vitis straight: 25.24 ± 12.21%; p ≤ 0.001), whereat best ECE was achieved in isosceles triangle IDR of 1.0-1.1 mm (IDB micro 0.9: 70.7 ± 7.7%; PHB angled S: 57.30 ± 4.43%; p < 0.001). The highest ECF occurred for Vitis straight M with 2.11 ± 0.46 N, while IDB micro 0.9 showed lowest ECF values (0.64 ± 0.14 N; p < 0.001). CONCLUSIONS: IRP with an Archimedes´ screw design and a higher taper were associated with advanced ECE but also higher ECF, nevertheless, ECE didn't reach the cleaning efficacy of conventional IDBs.


Assuntos
Dispositivos para o Cuidado Bucal Domiciliar , Placa Dentária , Humanos , Borracha , Escovação Dentária/métodos , Parafusos Ósseos
4.
Cont Lens Anterior Eye ; 47(2): 102104, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38161140

RESUMO

PURPOSE: The purpose of this study was to explore the impact of several contact lens (CL) care solutions on the removal of proteins and lipids, and how deposit removal impacts bacterial adhesion and solution disinfection. METHODS: Lysozyme and lipid deposition on three ortho-k (rigid) and two soft CL materials were evaluated using an ELISA kit and gas chromatography respectively. Bacterial adhesion to a fluorosilicone acrylate material using Pseudomonas aeruginosa with various compositions of artificial tear solutions (ATS), including with denatured proteins, was also investigated. The impact of deposition of the different formulations of ATS on biofilm formation was explored using cover slips. Finally, the lysozyme and lipid cleaning efficacy and disinfection efficacy against P. aeruginosa and Staphylococcus aureus of four different contact lens care solutions were studied using qualitative analysis. RESULTS: While maximum lysozyme deposition was observed with the fluorosilicone acrylate material (327.25 ± 54.25 µg/lens), the highest amount of lipid deposition was recorded with a fluoro-siloxanyl styrene material (134.71 ± 19.87 µg/lens). Adhesion of P. aeruginosa to fluorosilicone acrylate lenses and biofilm formation on cover slips were significantly greater with the addition of denatured proteins and lipids. Of the four contact lens care solutions investigated, the solution based on povidone-iodine removed both denatured lysozyme and lipid deposits and could effectively disinfect against P. aeruginosa and S. aureus when contaminated with denatured proteins and lipids. In contrast, the peroxide-based solution was able to inhibit P. aeruginosa growth only, while the two multipurpose solutions were unable to disinfect lenses contaminated with denatured proteins and lipids. CONCLUSION: Bacterial adhesion and biofilm formation is influenced by components within artificial tear solutions depositing on lenses, including denatured proteins and lipids, which also affects disinfection. The ability of different solutions to remove these deposits should be considered when selecting systems to clean and disinfect ortho-k lenses.


Assuntos
Lentes de Contato Hidrofílicas , Muramidase , Humanos , Lubrificantes Oftálmicos , Aderência Bacteriana , Staphylococcus aureus , Proteínas , Soluções para Lentes de Contato/farmacologia , Lipídeos/análise , Acrilatos
5.
Int Endod J ; 57(1): 87-99, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37947444

RESUMO

AIM: To investigate the influence of pulse energy, tip geometry and tip position in simulated 3D-printed root canals with multiple side canals at different levels in all directions on the cleaning performance of laser-activated irrigation (LAI) compared to sonic activation (EDDY) and conventional needle irrigation (NI). METHODOLOGY: 3D-printed root canal models (25/.06, length 20 mm, curvature 60°, radius 5 mm) with side canals (diameter 0.2 mm) at 2, 5 and 8 mm from the apex were filled with coloured biofilm-mimicking hydrogel. LAI (Morita AdvErL Evo, Kyoto, Japan) was performed with six settings (n = 20; pulse-energy, pulses per second [PPS], tip position): LAI1 (50 mJ, 25 PPS, P400FL, canal entrance [CE]), LAI2 (same as LAI1, but insertion depth 9 mm before the apical endpoint [AE] [corresponding to 1 mm above the first lateral canals]), LAI3 (80 mJ, 25 PPS, P400FL, 9 mm before AE), LAI4 (same as LAI 3, but at CE) for 3 × 20 s each, LAI5 (50 mJ, 25 PPS, P400FL 2 × 20 s, CE & R200T (30 mJ, 25 PPS, 1 × 20 s, 9 mm before AE), LAI6 (30 mJ, 25 PPS, R200T, 9 mm before AE, 3 × 20 s). A continuous irrigation (3 mL/20 s) using distilled water accompanied the irrigation cycles. NI and EDDY (3 × 20 s each; 3 mL/20 s irrigation, insertion AE minus 1 mm, amplitude 4 mm) served as control groups. Biofilm-mimicking hydrogel removal (ImageJ, NIH) was assessed for the entire system, the central canal and the lateral canals using standardized photographs with a microscope (Expert DN, Müller-Optronic) and statistically analysed was performed using Kruskal-Wallis and Dunn tests (p = .05). Irrigant extrusion beyond the foramina was also recorded. RESULTS: LAI2 (99.08%; interquartile range [IQR]: 96.85-100.00) and LAI3 (97.50%; 96.24-100.00) achieved the significantly best and LAI6 (80.08%; 73.41-84.69) the significantly worst removal of hydrogel from the entire root canal system amongst all LAI configurations (p < .05). There were no significant differences between LAI6, EDDY (72.89%; 67.49-76.22) and manual irrigation (54.39%; 51.01-56.94) (p > .05). R200T laser tip caused significantly more often irrigant extrusion than all other techniques (p < .05). CONCLUSION: Tip design, energy settings, and the positioning of the laser tip below the canal entrance caused an improvement in cleaning performance of the LAI. However, the small R200T tip created significantly more procedural errors (irrigant extrusion) due to higher concentrated energy.


Assuntos
Cavidade Pulpar , Lasers de Estado Sólido , Preparo de Canal Radicular/métodos , Lasers de Estado Sólido/uso terapêutico , Irrigantes do Canal Radicular , Hidrogéis , Irrigação Terapêutica/métodos
6.
Textiles (Basel) ; 3(2): 201-218, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37786877

RESUMO

The National Fire Protection Association (NFPA) 1851 document provides guidelines for firefighters on the care and maintenance of their PPE, including decontamination practices. Firefighters are exposed to various toxic chemicals during fire suppression activities, making effective decontamination crucial for their safety. This study evaluated the efficacy of different washing parameters, including temperature, time, and surfactants, on cleaning outer-shell material contaminated with nine targeted compounds from three different functional groups: phenols, polycyclic aromatic hydrocarbons (PAHs), and phthalates. The study was conducted on both bench-scale and full-scale levels, with contaminated swatches washed in a water shaker bath in the bench-scale evaluation and full-sized washer extractors used in the full-scale evaluation. The results showed that bench-scale washing demonstrated similar trends in contaminant removal to full-scale washing. Importantly, the study highlighted the complexity of removing fireground contaminants from the personal protective ensemble (PPE). The findings of this study have practical implications for the firefighting industry as they provide insight into the effectiveness of different washing parameters for PPE decontamination. Future studies could explore the impact of repeated washing on PPE and investigate the potential for developing more efficient decontamination strategies. Ultimately, the study underscores the importance of ongoing efforts to ensure the safety of firefighters, who face significant occupational hazards.

7.
Oral Health Prev Dent ; 21(1): 153-162, 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37195331

RESUMO

PURPOSE: This study investigated the effect of toothbrush bristle stiffness and brushing force on the cleaning efficacy in vitro. MATERIALS AND METHODS: Eighty bovine dentin samples were allocated to eight groups (n=10). Two custom-made toothbrushes of different bristle stiffness (soft and medium) were tested at four different brushing forces (1, 2, 3 and 4 N). Dentin samples were stained in black tea and brushed (60 strokes/min) for a total of 25 min in a brushing machine with an abrasive solution (RDA 67). Photographs were taken after 2 and 25 min of brushing time. Cleaning efficacy was measured planimetrically. RESULTS: After 2 min of brushing, the soft-bristle toothbrush did not cause statistically significantly different cleaning efficacy at different brushing forces, while the medium-bristle toothbrush cleaned statistically significantly less efficaceously only at 1 N. Comparing the two different toothbrushes, higher cleaning efficacy was observed only at 1 N for the soft-bristle brush. At 25 min brushing time, the soft-bristle cleaned statistically significantly better at 4 N compared to 1 N and 2 N and at 3 N compared to 1 N. Using the medium-bristle, cleaning efficacy increased with increasing brushing force. After 25 min of brushing, no statistically significant difference was observed between the two different toothbrushes. CONCLUSION: Irrespective the brushing force, the use of a soft or medium toothbrush results in comparable cleaning efficacy. At 2 min brushing time, increasing the brushing force does not increase the cleaning efficacy.


Assuntos
Acidente Vascular Cerebral , Escovação Dentária , Humanos , Animais , Bovinos , Chá , Desenho de Equipamento
8.
BMC Oral Health ; 22(1): 225, 2022 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-35676648

RESUMO

BACKGROUND: Toothbrushes require flexibility to access all dental surfaces and remove plaque effectively, but they should also aim to prevent or limit overbrushing and consequent damage to teeth and gums. In two studies, the physical properties and cleaning performance of specialist test toothbrushes with flexible necks were compared to a reference rigid-necked toothbrush. METHODS: In Study 1, a universal testing machine (Instron E 10,000) with a specially designed setup was used to test the deflection behaviour of toothbrush head and neck. Untufted toothbrushes were fixed in a custom holder and force was applied to the head while the deflection was measured. In Study 2, one control and five test toothbrushes were assessed using a robot system to simulate the cleaning of artificial plaque from defined surfaces of artificial replicated human teeth in a model oral cavity (typodonts). RESULTS: Study 1 showed that the flexible-neck toothbrush deflected 2 to 2.5 times more than the rigid-neck reference toothbrush when same force was applied to the toothbrush head. Study 2 revealed that all five test toothbrushes showed statistically superior simulated plaque removal to the reference toothbrush. This superiority was observed for all test toothbrushes employing horizontal and rotating brushing action (all p = 0.001) but only three of the five toothbrushes when vertical brushing was employed (all p = 0.001). Cleaning efficacy of the test toothbrushes was demonstrated both interdentally and at the gumline locations. The Complete Protection toothbrush showed the most effective cleaning performance followed by the Repair and Protect and Rapid Relief toothbrushes. CONCLUSION: The addition of a flexible-neck component to the toothbrush designs helped to reduce stiffness and may allow more effective cleaning compared to rigid designs with controlled force distribution on the teeth and gums. This may help to provide plaque control at all potential risk areas in an in vitro robot model and could support good oral hygiene in-use.


Assuntos
Placa Dentária , Robótica , Placa Dentária/prevenção & controle , Índice de Placa Dentária , Desenho de Equipamento , Humanos , Testes Mecânicos , Escovação Dentária
9.
Int J Clin Pediatr Dent ; 14(2): 196-200, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34413591

RESUMO

AIM AND OBJECTIVE: Apical extrusion of debris and cleaning efficacy in primary root canal treatment has not been well elucidated by using specialized pediatric rotary endodontic files. The purpose of this study is to compare the amount of apically extruded debris and cleaning efficacy during the preparation of primary molar root canals using Pro AF Baby Gold and Kedo-S pediatric rotary files. MATERIALS AND METHODS: Twenty extracted primary molar teeth were assigned randomly to two groups (n = 10 teeth for each group), injected with Indian Ink and instrumented using Kedo-S and Pro AF Baby Gold pediatric rotary files, respectively. The apically extruded debris was collected and dried in pre-weighed using Eppendorf tubes. The dry weight was calculated by subtracting the preoperative weight from the postoperative weight. The cleaning efficacy was evaluated after the diaphanization process. Statistics: Data were analyzed statistically using the independent sample t-test. RESULTS: The amount of apically extruded debris was significantly less for the Pro AF Baby rotary files group compared to the Kedo-S rotary files group (p < 0.05). Cleaning efficacy was significantly better with Pro AF Baby Gold when compared to Kedo-S rotary files in the apical region of the tooth. CONCLUSION: All instruments caused apically extruded debris in primary teeth. Pro AF baby Gold files can be used with less apical extrusion of debris. Cleaning efficacy was shown to be better with the Pro AF Baby Gold pediatric rotary endodontic file. HOW TO CITE THIS ARTICLE: Rathi N, Jain SA, Thosar N, et al. Comparative Evaluation of Cleaning Efficiency and Apical Extrusion of Debris Using Two Pediatric Rotary Endodontic Files: An In Vitro Study. Int J Clin Pediatr Dent 2021;14(2):196-200.

10.
BMC Oral Health ; 21(1): 194, 2021 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-33853594

RESUMO

BACKGROUND: Interdental brushes (IDB) are according to the actual evidence the first choice for cleaning interdental areas (IDR). Their size should be chosen individually according to the IDR morphology. However, interdental rubber picks (IRP) are appreciated better by the patients and are hence becoming more and more popular but the evidence regarding their efficacy is still limited. The aim of this in vitro study was to measure the experimental cleaning efficacy (ECE) and force (ECF) during the use of interdental brushes versus newer wireless types with rubber filaments (IRP), both fitted and non-fitted for different IDR. METHODS: The medium size of a conical IRP (regular, ISO 2) with elastomeric fingers versus four sizes (ISO 1, 2, 3, 4) of cylindric IDB with nylon filaments (all Sunstar Suisse SA, Etoy, Switzerland) were tested. Interdental tooth surfaces were reproduced by a 3D-printer (Form 2, Formlabs Sommerville, MA, USA) according to human teeth and matched to morphologically equivalent pairs (isosceles triangle, concave, convex) fitting to three different gap sizes (1.0 mm, 1.1 mm, 1.3 mm). The pre-/post brushing situations at IDR (standardized, computer aided ten cycles) were photographically recorded and quantified by digital image subtraction to calculate ECE [%]. ECF were registered with a load cell [N]. RESULTS: Overall, a higher ECE was recorded for IDB compared to IRP (58.3 ± 14.9% versus 18.4 ± 10.1%; p < 0.001). ECE significantly depended on the fitting of the IDB. ECE was significant higher in isosceles triangle compared to concave and convex IDR for both IDB and IRP (p ≤ 0.001). ECF was lower for IDB (0.6 ± 0.4N) compared to IRP (0.8 ± 0.5N; p ≤ 0.001). ECE in relation to ECF increases with smaller IDB. For IRP highest values of ECF were found in the smallest IDR. CONCLUSIONS: Within the limitations of an in vitro study, size fitted IDB cleaned more effectively at lower forces compared to conical IRP.


Assuntos
Dispositivos para o Cuidado Bucal Domiciliar , Placa Dentária , Humanos , Borracha , Suíça , Escovação Dentária
11.
BMC Oral Health ; 20(1): 136, 2020 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-32384897

RESUMO

BACKGROUND: Interdental rubber picks (IRP) have become a frequent and convenient alternative for interdental cleaning. However, only little evidence exists supporting the effectiveness of newer designs available on the market. Therefore, a new in vitro model was evaluated to measure the experimental cleaning efficacy (ECE), as well as the force needed for insertion and during the use of IRP, with high reproducibility. METHODS: Five different sizes of commercially marketed IRP with elastomeric fingers (IRP-F) (GUM SOFT-PICKS® Advanced, Sunstar Deutschland GmbH, Schönau, Germany) or slats (IRP-S) (TePe EasyPick™, TePe D-A-CH GmbH, Hamburg, Germany) were tested. Interdental tooth surfaces were reproduced by a 3D-printer (Form 2, Formlabs Sommerville, MA, USA) according to human teeth and matched to morphologically equivalent pairs (isosceles triangle, concave, convex) fitting to different gap sizes (1.0 mm, 1.1 mm, 1.3 mm). The pre-/post brushing situations at interdental areas (standardized cleaning, computer aided ten cycles) were photographically recorded and quantified by digital image subtraction to calculate ECE [%]. Forces were registered with a load cell [N]. RESULTS: IRP-F have to be inserted with significant higher forces of 3.2 ± 1.8 N compared to IRP-S (2.0 ± 1.6 N; p < 0.001) independent of the size and type of artificial interdental area. During cleaning process IRP-S showed significantly lower values for pushing/pulling (1.0 ± 0.8 N/0.5 ± 0.4 N) compared to IRP-F (1.6 ± 0.8 N/0.7 ± 0.3 N; p < 0.001) concomitant to significantly lower ECE (19.1 ± 9.8 vs. 21.7 ± 10.0%, p = 0.002). Highest ECE was measured with largest size of IRP-F/IRP-S independent the morphology of interdental area. CONCLUSIONS: New interdental cleaning aids can be tested by the new experimental setup supported by 3D printing technology. Within the limitations of an in vitro study, IRP-F cleaned more effectively at higher forces compared to IRP-S.


Assuntos
Dispositivos para o Cuidado Bucal Domiciliar , Placa Dentária/prevenção & controle , Escovação Dentária/instrumentação , Alemanha , Humanos , Fotografia Dentária , Pressão , Reprodutibilidade dos Testes , Escovação Dentária/métodos
12.
Indian J Dent Res ; 30(3): 420-423, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31397419

RESUMO

CONTEXT: The presence of smear layer and debris can prevent the irrigant and sealer from penetrating the dentinal tubules thereby compromising the seal of the root canal filling. AIM: This study aims to evaluate the efficacy of XP-endo Finisher with ProTaper Next and HyFlex in smear layer and debris removal. MATERIALS AND METHODS: : Thirty-two extracted mandibular premolar teeth were selected and sectioned at the cementoenamel junction. The roots were then randomly divided into 4 groups. In group 1 and 2, canals were instrumented with X2 ProTaper Next (25 0.06 taper). In group 3 and 4, canals were instrumented with HyFlex system (25 0.06 taper). The canals in group 2 and 4 were further finished with XP-endo Finisher. Irrigation was carried out using 3% sodium hypochlorite during instrumentation, and 17% ethylenediaminetetraacetic acid was used as the final rinse. The roots were then split longitudinally. The canal wall was observed under the scanning electron microscope in coronal, middle, and apical thirds at a magnification of ×400 and ×1000 for evaluation of debris and smear layer, respectively. Photomicrographs were taken, and qualitative assessment for debris and smear layer removal was done. STATISTICAL ANALYSIS USED: The results were analyzed using Kruskal-Wallis test and Mann-Whitney U-test. RESULTS: Lower debris and smear layer scores were seen in canal thirds instrumented with ProTaper Next and XP-endo Finisher (P < 0.01). CONCLUSION: The use of XP-endo Finisher as an adjuvant during shaping and cleaning produced cleaner root canal walls.


Assuntos
Camada de Esfregaço , Cavidade Pulpar , Elétrons , Humanos , Microscopia Eletrônica de Varredura , Irrigantes do Canal Radicular , Preparo de Canal Radicular
13.
Artigo em Inglês | MEDLINE | ID: mdl-31134160

RESUMO

Given the increasing prevalence of antibiotic resistance among bacterial strains and the side effects caused by synthetic drugs, it is increasingly important to investigate potential herbal alternatives. In the present study, antimicrobial, cell cytotoxicity, and cleaning tests were performed to evaluate the potential of Fufang Bingpeng irrigant as a root canal irrigant, in addition to q-PCR and high-throughput sequencing analyses. Our in vitro results showed a low minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of Fufang Bingpeng irrigant against Porphyromonas gingivalis ATCC 33277 (6.25 and 12.5%, respectively), Prevotella intermedius ATCC 25611 (6.25 and 6.25%, respectively), Fusobacterium nucleatum ATCC 25286 (6.25 and 6.25%, respectively), Enterococcus faecalis ATCC 19433 (25 and 25%, respectively), and Bacteriodes fragilis ATCC 25285 (12.5 and 12.5%, respectively). Furthermore, it effectively removed the remaining debris and increased the number of open dentinal tubules in root canals compared to the NaCl irrigant (p < 0.05). Fufang Bingpeng irrigant also presented low cytotoxicity to L929 cells compared to the NaClO irrigant. The in vivo results indicated that all irrigants used significantly reduced the number of bacteria compared to the number prior to treatment, and only 1/104.95 bacteria remained in the root canal following the use of Fufang Bingpeng irrigant (p < 0.001). Moreover, the high-throughput sequencing results indicated that all irrigants markedly enhanced the α diversity in the root canal compared to the before preparation control group, while Fufang Bingpeng maintained better microbial diversity than other groups. Therefore, Fufang Bingpeng irrigant presents a promising alternative for use as a root canal irrigant in clinical settings.


Assuntos
Anti-Infecciosos/administração & dosagem , Irrigantes do Canal Radicular/administração & dosagem , Hipoclorito de Sódio/administração & dosagem , Ultrassom/métodos , Adolescente , Linhagem Celular/efeitos dos fármacos , Criança , DNA Bacteriano/análise , Cavidade Pulpar/microbiologia , Medicamentos de Ervas Chinesas/administração & dosagem , Enterococcus faecalis/efeitos dos fármacos , Fusobacterium nucleatum/efeitos dos fármacos , Ensaios de Triagem em Larga Escala , Humanos , Testes de Sensibilidade Microbiana , Porphyromonas gingivalis/efeitos dos fármacos , Prevotella/efeitos dos fármacos , Preparo de Canal Radicular , Tratamento do Canal Radicular , Terapia por Ultrassom
14.
J Oral Biol Craniofac Res ; 9(2): 151-155, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30963021

RESUMO

AIM: To compare the timing of instrumentation and cleaning efficacy between manual K files and NiTi rotary files in extracted primary molars. STUDY DESIGN: in-vitro study was conducted in 90 root canals of extracted primary molars which were subdivided in three groups viz. Control (No instrumentation), Manual (K files), Rotary (ProFiles) with 30 canals in each group. Mesiobuccal (MB) and Mesiolingual (ML) canals of mandibular molars, and MB and Distobuccal (DB) canals of maxillary molars were included in the test group whereas Distal canals in mandibular molars and Palatal canals in maxillary molars were included in the control group. METHOD: Teeth were mounted and canals were injected with India ink to stain the canal walls. Canal preparation was done as per the group. After instrumentation, teeth were demounted, decalcified and cleared to make them transparent for scoring according to the extent of removal of India ink. Timing of instrumentation and cleaning efficacy of canals in coronal, middle and apical thirds were assessed in each sample. RESULTS: Mean timing of instrumentation in rotary group was 3.54 ±â€¯1.14 min and 4.32 ±â€¯1.04 min in manual group. Mean cleaning efficacy scores in manual and rotary groups were 2.03 and 1.66 in coronal third, 1.08 and 1.18 in middle third and 0.67 and 1.08 in apical third respectively. Inter-group comparisons showed no statistically significant difference in cleaning efficacy among test groups in all thirds of root canals. CONCLUSION: NiTi rotary technique has comparable cleaning efficacy, with significantly less timing of instrumentation compared to manual K-files.

15.
J Endod ; 42(8): 1268-72, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27339632

RESUMO

INTRODUCTION: This study aimed to evaluate the efficacy of a new irrigation system (EndoIrrigator Plus; Innovations Endo, Nasik, India) using a histologic method ex vivo. METHODS: Mandibular molars with a normal pulp extracted for periodontal reasons (N = 68) were assessed for the presence of an isthmus using cone-beam computed tomographic imaging. Root canals of the included molars (n = 40) were instrumented up to a ProTaper F2 instrument (Dentsply Maillefer, Baillagues, Switzerland) using 3% sodium hypochlorite as irrigant in a closed apical design. Final irrigation delivery/activation was performed as follows (n = 10): group 1, syringe irrigation; group 2, apical negative pressure delivery with continuous warm activated irrigation and evacuation system (CWAIS); group 3, manual dynamic agitation (MDA); and group 4, passive ultrasonic irrigation (PUI). Untreated teeth (n = 5) served as histologic controls. The isthmus regions (1, 3, and 5 mm from the apex) were analyzed by hematoxylin-eosin stain to calculate the percentage of remaining pulp tissue (RPT) relative to the area of the isthmus. Results were analyzed using the Mann-Whitney U test (P = .05). RESULTS: CWAIS showed significantly less RPT than the other groups at all 3 root levels (P < .05). MDA showed significantly less RPT at 1 and 3 mm from the apex compared with PUI and syringe irrigation (P < .05). There was no significant difference between PUI and MDA at the 5-mm level (P > .05). CONCLUSIONS: None of the methods could completely clean the isthmus. CWAIS left behind the least amount of RPT.


Assuntos
Desbridamento/métodos , Dente Molar/cirurgia , Irrigantes do Canal Radicular/uso terapêutico , Preparo de Canal Radicular/instrumentação , Hipoclorito de Sódio/uso terapêutico , Irrigação Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico , Humanos , Técnicas In Vitro , Mandíbula , Ultrassom/instrumentação
16.
Am J Infect Control ; 44(7): e107-11, 2016 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-27040564

RESUMO

BACKGROUND: Following a Clostridium difficile infection outbreak, the Infection Prevention and Control team at our institution queried the risk of transmission via bedpans reprocessed in washer disinfectors (WDs). This study's objective was to determine the effectiveness of the mechanical action, detergent, and temperature on the eradication of C difficile spores in 1 type of WD model. MATERIALS AND METHODS: Three types of reusable bedpans/pots were inoculated with sterile human feces that contained 1 × 10(7) CFU/mL C difficile spores. The 0.3 mL fecal-spore suspension was inoculated in sealed cryovials. These items were reprocessed using the longest wash cycle of WDs in 9 clinical units, and then tested for residual C difficile spores. The number of colonies on each replicate organism detection and counting plate was recorded after anaerobic incubation at 35°C for 48 hours, and the log reduction was calculated. RESULTS: All 9 WDs met the manufacturer's operational specifications. Forty-three (96%) of 45 bedpans had no viable spores (>5.9 log10C difficile spore reduction). Two bedpans had 1 to 2 spores remaining. Viable C difficile spores were isolated from all 9 cryovials. DISCUSSION AND CONCLUSIONS: Results demonstrated that when operating the WD as stipulated, C difficile spores were satisfactorily eliminated from bedpan surfaces. Temperature alone was insufficient to kill C difficile spores. It also suggested the importance of staff training, machine maintenance, and WD purchase specifications.


Assuntos
Aparelho Sanitário/microbiologia , Clostridioides difficile/isolamento & purificação , Desinfecção/métodos , Esporos/isolamento & purificação , Instalações de Saúde , Humanos , Reprodutibilidade dos Testes , Temperatura
17.
Biochem Biophys Rep ; 1: 1-7, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26339684

RESUMO

A thermostable adenylate kinase (tAK) has been used as model protein contaminant on surfaces, so used because residual protein after high temperature wash steps can be detected at extremely low concentrations. This gives the potential for accurate, quantitative measurement of the effectiveness of different wash processes in removing protein contamination. Current methods utilise non-covalent (physisorbtion) of tAK to surfaces, but this can be relatively easily removed. In this study, the covalent binding of tAK to surfaces was studied to provide an alternative model for surface contamination. Kinetic analysis showed that the efficiency of the enzyme expressed as the catalytic rate over the Michaelis constant (kcat/KM) increased from 8.45±3.04 mM-1 s-1 in solution to 32.23±3.20 or 24.46±4.41 mM-1 s-1 when the enzyme was immobilised onto polypropylene or plasma activated polypropylene respectively. Maleic anhydride plasma activated polypropylene showed potential to provide a more robust challenge for washing processes as it retained significantly higher amounts of tAK enzyme than polypropylene in simple washing experiments. Inhibition of the coupled enzyme (luciferase/luciferin) system used for the detection of adenylate kinase activity, was observed for a secondary product of the reaction. This needs to be taken into consideration when using the assay to estimate cleaning efficacy.

18.
Clin Oral Implants Res ; 25(10): 1149-60, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23834327

RESUMO

OBJECTIVE: The objective of this systematic review was to evaluate the ability of mechanical instruments to clean contaminated implant titanium surfaces. MATERIALS AND METHODS: MEDLINE, Cochrane-CENTRAL and EMBASE databases were searched up to May 2013 to identify controlled studies on the cleaning efficacy of mechanical instruments on contaminated titanium surfaces. RESULTS: A comprehensive search identified 1893 unique potential papers. Fourteen studies met the inclusion criteria and were selected for this systematic review. Most of the studies were in vitro studies. Different surfaces and different contamination methods were used. Most studies used titanium discs, strips and cylinders. The air abrasive was the treatment mostly evaluated. The available studies had a high heterogeneity that precluded any statistical analysis of the data. Therefore, the conclusions are not based on quantitative data. Non-metal curettes and rubber cups were found to be ineffective. Positive results were reported for (ultra)sonic scalers with a metal tip on polished surfaces, (ultra)sonic scalers with a non-metal tip on smooth and sand-blasted and acid-etched (SLA) surfaces, metal curettes and rotating titanium brushes on SLA surfaces. The air abrasive was found to be effective in cleaning machined, SLA and titanium plasma-sprayed (TPS) surfaces. CONCLUSION: The available data suggest that the air abrasive may remove plaque effectively from machined, SLA and TPS titanium surfaces. Positive results were also observed for rotating titanium brushes on SLA surfaces and ultrasonic scalers with non-metal tip on polished and SLA surfaces. However, the clinical impact of these findings requires further clarification.


Assuntos
Biofilmes , Descontaminação/instrumentação , Implantes Dentários/microbiologia , Instrumentos Odontológicos , Humanos , Teste de Materiais , Propriedades de Superfície , Titânio
19.
Iran Endod J ; 4(2): 53-7, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-23940486

RESUMO

INTRODUCTION: Pulpectomy of primary teeth is commonly carried out with hand files and broaches; a tricky and time consuming procedure. The purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous molars using hand K-files and Flex Master rotary system. MATERIALS AND METHODS: In this study, 68 canals of 23 extracted primary molars with at least two third intact roots and 7-12 mm length were selected. After preparing an access cavity, K-file size #15 was introduced into the root canal and India ink was injected with an insulin syringe. Sixty samples were randomly divided in to experimental groups in group I (n=30), root canals were prepared with hand K-files; in group II (n=30), rotary Flex Master files were used for instrumentation, and in group III 8 remained samples were considered as negative controls. After clearing and root sectioning, the removal of India ink from cervical, middle, and apical thirds was scored. Data was analyzed using student's T-test and Mann-Whitney U test. RESULTS: There was no significant difference between experimental groups cleaning efficacy at the cervical, middle and apical root canal thirds. Only the coronal third scored higher in the hand instrumented group (P<0.001). Instrumentation with Flex Master rotary files was significantly less time consuming (P<0.001). CONCLUSION: Although there was no difference in cleanliness efficacy at the apical and middle thirds, the coronal third was more effectively cleaned with hand files. Predictably, time efficiency was a significant advantage with rotary technique.