Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 537
Filtrar
1.
J Clin Med ; 13(14)2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-39064110

RESUMO

Dual-Energy computed tomography (DECT) with its various advanced techniques, including Virtual Non-Contrast (VNC), effective atomic number (Z-eff) calculation, Z-maps, Iodine Density Index (IDI), and so on, holds great promise in the diagnosis and management of urogenital tumours. In this narrative review, we analyze the current status of knowledge of this technology to provide better lesion characterization, improve the staging accuracy, and give more precise treatment response assessments in relation to urological tumours.

2.
Insights Imaging ; 15(1): 173, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38981953

RESUMO

OBJECTIVES: To develop and validate a dual-energy CT (DECT)-based model for noninvasively differentiating between benign and malignant breast lesions detected on DECT. MATERIALS AND METHODS: This study prospectively enrolled patients with suspected breast cancer who underwent dual-phase contrast-enhanced DECT from July 2022 to July 2023. Breast lesions were randomly divided into the training and test cohorts at a ratio of 7:3. Clinical characteristics, DECT-based morphological features, and DECT quantitative parameters were collected. Univariate analyses and multivariate logistic regression were performed to determine independent predictors of benign and malignant breast lesions. An individualized model was constructed. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic ability of the model, whose calibration and clinical usefulness were assessed by calibration curve and decision curve analysis. RESULTS: This study included 200 patients (mean age, 49.9 ± 11.9 years; age range, 22-83 years) with 222 breast lesions. Age, lesion shape, and the effective atomic number (Zeff) in the venous phase were significant independent predictors of breast lesions (all p < 0.05). The discriminative power of the model incorporating these three factors was high, with AUCs of 0.844 (95%CI 0.764-0.925) and 0.791 (95% CI 0.647-0.935) in the training and test cohorts, respectively. The constructed model showed a preferable fitting (all p > 0.05 by the Hosmer-Lemeshow test) and provided enhanced net benefits than simple default strategies within a wide range of threshold probabilities in both cohorts. CONCLUSION: The DECT-based model showed a favorable diagnostic performance for noninvasive differentiation between benign and malignant breast lesions detected on DECT. CRITICAL RELEVANCE STATEMENT: The combination of clinical and morphological characteristics and DECT-derived parameter have the potential to identify benign and malignant breast lesions and it may be useful for incidental breast lesions on DECT to decide if further work-up is needed. KEY POINTS: It is important to characterize incidental breast lesions on DECT for patient management. DECT-based model can differentiate benign and malignant breast lesions with good performance. DECT-based model is a potential tool for distinguishing breast lesions detected on DECT.

3.
Neuroradiology ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38985319

RESUMO

PURPOSE: To develop thrombus radiomics models based on dual-energy CT (DECT) for predicting etiologic cause of stroke. METHODS: We retrospectively enrolled patients with occlusion of the middle cerebral artery who underwent computed tomography (NCCT) and DECT angiography (DECTA). 70 keV virtual monoenergetic images (simulate conventional 120kVp CTA images) and iodine overlay maps (IOM) were reconstructed for analysis. Five logistic regression radiomics models for predicting cardioembolism (CE) were built based on the features extracted from NCCT, CTA and IOM images. From these, the best one was selected to integrate with clinical information for further construction of the combined model. The performance of the different models was evaluated and compared using ROC curve analysis, clinical decision curves (DCA), calibration curves and Delong test. RESULTS: Among all the radiomic models, model NCCT+IOM performed the best, with AUC = 0.95 significantly higher than model NCCT, model CTA, model IOM and model NCCT+CTA in the training set (AUC = 0.88, 0.78, 0.90,0.87, respectively, P < 0.05), and AUC = 0.92 in the testing set, significantly higher than model CTA (AUC = 0.71, P < 0.05). Smoking and NIHSS score were independent predictors of CE (P < 0.05). The combined model performed similarly to the model NCCT+IOM, with no statistically significant difference in AUC either in the training or test sets. (0.96 vs. 0.95; 0.94 vs. 0.92, both P > 0.05). CONCLUSION: Radiomics models constructed based on NCCT and IOM images can effectively determine the source of thrombus in stroke without relying on clinical information.

4.
Int J Med Sci ; 21(9): 1640-1648, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39006836

RESUMO

Objective: Our study aims to evaluate the value of 256-slice dual-energy computed tomography (DECT) in supporting prostatic artery embolization (PAE) under digital subtraction angiography (DSA) for benign prostatic hyperplasia (BPH). Methods: The study was conducted on 88 patients who underwent PAE to treat BPH from January 2022 to November 2023. Of these, 38 patients who had PAE without DECT were placed in group 1, while the other 50 patients with pre-interventional DECT were assigned to group 2. The results of DECT imaging of the prostate artery (PA) were compared with the results of DSA imaging. Test for statistically significant differences between the variables of the two research groups using the T - student test and Mann-Whitney test algorithms with p < 0.05 corresponding to a 95% confidence interval. The data were analyzed according to medical statistical methods using SPSS 20.0 software. Results: DECT can detect the PA origin in 96.1% of cases, identify atherosclerosis at the root of the artery with a sensitivity of 66.7% and a specificity of 89.5%, and present anastomosis with a sensitivity of 72.7% and a specificity of 72.2%. There is no statistically significant difference in PA diameter on DECT compared to DSA with 95% confidence. Group 2 used DECT for 3D rendering of the PA before PAE had procedure time reduced by 25.8%, fluoroscopy time reduced by 23.2%, dose-area product (DAP) reduced by 25.6%, contrast medium volume reduced by 33.1% compared to group 1 not using DECT, statistically significant with 95% confidence. Conclusion: DECT is a valuable method for planning before PAE to treat BPH. 3D rendering DECT of PA provides anatomical information that minimizes procedure time, fluoroscopy time, dose-area product, and contrast medium volume.


Assuntos
Angiografia Digital , Embolização Terapêutica , Próstata , Hiperplasia Prostática , Humanos , Hiperplasia Prostática/diagnóstico por imagem , Hiperplasia Prostática/terapia , Masculino , Embolização Terapêutica/métodos , Idoso , Próstata/diagnóstico por imagem , Próstata/irrigação sanguínea , Próstata/patologia , Angiografia Digital/métodos , Pessoa de Meia-Idade , Artérias/diagnóstico por imagem , Resultado do Tratamento , Tomografia Computadorizada por Raios X/métodos
5.
Front Physiol ; 15: 1399407, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39050483

RESUMO

Background: The effects of obesity on pulmonary gas and blood distribution in patients with acute respiratory failure remain unknown. Dual-energy computed tomography (DECT) is a X-ray-based method used to study regional distribution of gas and blood within the lung. We hypothesized that 1) regional gas/blood mismatch can be quantified by DECT; 2) obesity influences the global and regional distribution of pulmonary gas and blood; 3) regardless of ventilation modality (invasive vs. non-invasive ventilation), patients' body mass index (BMI) has an impact on pulmonary gas/blood mismatch. Methods: This single-centre prospective observational study enrolled 118 hypoxic COVID-19 patients (92 male) in need of respiratory support and intensive care who underwent DECT. The cohort was divided into three groups according to BMI: 1. BMI<25 kg/m2 (non-obese), 2. BMI = 25-40 kg/m2 (overweight to obese), and 3. BMI>40 kg/m2 (morbidly obese). Gravitational analysis of Hounsfield unit distribution of gas and blood was derived from DECT and used to calculate regional gas/blood mismatch. A sensitivity analysis was performed to investigate the influence of the chosen ventilatory modality and BMI on gas/blood mismatch and adjust for other possible confounders (i.e., age and sex). Results: 1) Regional pulmonary distribution of gas and blood and their mismatch were quantified using DECT imaging. 2) The BMI>40 kg/m2 group had less hyperinflation in the non-dependent regions and more lung collapse in the dependent regions compared to the other BMI groups. In morbidly obese patients, gas and blood were more evenly distributed; therefore, the mismatch was lower than in other patients (30% vs. 36%, p < 0.05). 3) An increase in BMI of 5 kg/m2 was associated with a decrease in mismatch of 3.3% (CI: 3.67% to -2.93%, p < 0.05). Neither the ventilatory modality nor age and sex affected the gas/blood mismatch (p > 0.05). Conclusion: 1) In a hypoxic COVID-19 population needing intensive care, pulmonary gas/blood mismatch can be quantified at a global and regional level using DECT. 2) Obesity influences the global and regional distribution of gas and blood within the lung, and BMI>40 kg/m2 improves pulmonary gas/blood mismatch. 3) This is true regardless of the ventilatory mode and other possible confounders, i.e., age and sex. Trial Registration: Clinicaltrials.gov, identifier NCT04316884, NCT04474249.

6.
Quant Imaging Med Surg ; 14(7): 4567-4578, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39022257

RESUMO

Background: Thyroid nodules (TNs) cytologically defined as category Bethesda III and IV pose a major diagnostic challenge before surgery, demanding new methods to reduce unnecessary diagnostic thyroid lobectomies for patients with benign TNs. This study aimed to assess whether a model combining dual-energy computed tomography (DECT) quantitative parameters with morphologic features could reliably differentiate between benign and malignant lesions in Bethesda III and IV TNs. Methods: Data from 77 patients scheduled for thyroid surgery for Bethesda III and IV TNs (malignant =48; benign =29) who underwent DECT scans were reviewed. DECT quantitative parameters including normalized iodine concentration (NIC), attenuation on the slope of spectral Hounsfield unit (HU) curve, and normalized effective atomic number (Zeff) were measured in the arterial phase (AP) and venous phase (VP). DECT quantitative parameters and morphologic features were compared between the malignant and benign cohorts. The receiver operating characteristic curve was performed to compare the performances of significant DECT quantitative parameters, morphologic features, or the models combining the DECT parameters, respectively, with morphologic features. A nomogram was constructed from the optimal performance model, and the performance was evaluated via the calibration curve and decision curve analysis. Results: The areas under the receiver operating characteristic curve with 95% confidence interval (CI) of the NIC in the AP (AP-NIC), slope of spectral HU curve in the AP, and NZeff in the AP were 0.749 (95% CI: 0.641-0.857), 0.654 (95% CI: 0.530-0.778), and 0.722 (95% CI: 0.602-0.842), respectively. The model combining AP-NIC with enhanced blurring showed the highest diagnostic performance, with an area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of 0.808, 0.854, and 0.655, respectively; it was then used to construct a nomogram. The calibration curve showed that the discrepancy between the prediction of the nomogram and actual observations was less than 5%. The decision curve analysis indicated the nomogram had a positive net benefit in threshold risk ranges of 14% to 58% or 60% to 91% for malignant Bethesda III and IV TNs. Conclusions: The model combining AP-NIC with enhanced blurring could reliably differentiate between benign and malignant lesions in Bethesda III and IV TNs.

7.
Quant Imaging Med Surg ; 14(7): 5084-5098, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39022275

RESUMO

Background: Whether to perform prophylactic central lymph node dissection for cN0 papillary thyroid carcinoma (PTC) patients is still controversial. This retrospective study aimed to develop and validate a nomogram based on ultrasound and dual-energy computed tomography (DECT) for the risk stratification of central lymph node metastasis (CLNM) in patients with PTC. Methods: A total of 525 patients from 2017 to 2019 [Tianjin First Central Hospital (Hospital A)] were retrospectively analyzed to form the training cohort and to conduct internal validation. Another group of 204 patients in 2020 (Hospital A) formed the temporal validation cohort. A total of 107 patients in 2020 [Binzhou Medical University Hospital (Hospital B)] formed the geographic validation cohort, which was a retrospective cohort study. The area under the curve (AUC), calibration curve, and decision curve were used to evaluate the performance of the nomogram. The locally weighted regression curve was used for risk stratification. Results: Diameter, taller-than-wide, calcification, capsular invasion, and iodine concentration in the arterial and venous phases were independent risk predictors of CLNM. The AUC of the nomogram was 0.922 (95% confidence interval: 0.895-0.943) in the training cohort. Two external validation cohorts demonstrated the good performance of the nomogram in predicting CLNM, with AUCs of 0.912 and 0.861. The significantly improved net reclassification index and integrated discriminatory improvement index indicated that DECT was a powerful supplement to ultrasound for predicting CLNM. The risk stratification system divided all patients into low-risk (0-50 points), intermediate-risk (51-100 points), and high-risk groups (>100 points). Conclusions: The nomogram and risk stratification system estimated the utility of CLNM to guide individualized treatment of patients with PTC.

8.
BMC Musculoskelet Disord ; 25(1): 557, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39020351

RESUMO

BACKGROUND: This meta-analysis assessed the efficacy of dual-energy computed tomography (DECT) in the diagnosis of anterior cruciate ligament (ACL) injuries. METHODS: The literature search was performed up to December 8, 2023, and included a comprehensive examination of several databases: PubMed, Embase, Cochrane Library, Web of Science, China National Knowledge Infrastructure (CNKI), Wanfang, and VIP. Diagnostic metrics sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and a summary receiver operating characteristic (SROC) were determined using a bivariate model analysis. Heterogeneity within the data was explored through subgroup analyses, which considered variables including geographical region, use of magnetic resonance imaging (MRI), arthroscopy, and study design. RESULTS: The analysis included ten studies encompassing 544 patients. DECT demonstrated substantial diagnostic utility for ACL injuries of the knee, with a sensitivity of 0.91 (95% confidence interval [CI]: 0.88-0.94), a specificity of 0.90 (95% CI: 0.81-0.95), a PLR of 9.20 (95% CI: 4.50-19.00), a NLR of 0.10 (95% CI: 0.06-0.14), a DOR of 97.00 (95% CI: 35.00-268.00), and an area under the curve (AUC) of 0.95 (95% CI: 0.93-0.97). The subgroup analyses consistently showed high diagnostic precision for ACL injuries across Asian population (sensitivity: 0.91, specificity: 0.91, PLR: 9.90, NLR: 0.09, DOR: 105.00, AUC: 0.96), in MRI subgroup (sensitivity: 0.85, specificity: 0.94, PLR: 9.57, NLR: 0.18, DOR: 56.00, AUC: 0.93), in arthroscopy subgroup (sensitivity: 0.92, specificity: 0.89, PLR: 8.40, NLR: 0.09, DOR: 94.00, AUC: 0.95), for prospective studies (sensitivity: 0.92, specificity: 0.88, PLR: 7.40, NLR: 0.09, DOR: 78.00, AUC: 0.95), and for retrospective studies (sensitivity: 0.91, specificity: 0.93, AUC: 0.93). CONCLUSION: DECT exhibits a high value in diagnosing ACL injuries. The significant diagnostic value of DECT provides clinicians with a powerful tool that enhances the accuracy and efficiency of diagnosis and optimizes patient management and treatment outcomes.


Assuntos
Lesões do Ligamento Cruzado Anterior , Tomografia Computadorizada por Raios X , Humanos , Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Traumatismos do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade
9.
Cureus ; 16(6): e62811, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39036172

RESUMO

INTRODUCTION: This study aimed to evaluate the potential of dual-energy computed tomography (CT) to distinguish postoperative ascites, pancreatic fistula, and abscesses. MATERIALS AND METHOD: Patients who underwent biliary and pancreatic surgery performed at our institution between June 2021 and February 2022 were included in the study. Postoperative body fluid samples were collected through a drain or percutaneous drainage. These samples were set in a phantom, and imaging data were obtained using dual-energy CT. Image analysis was performed to obtain CT values at each energy in virtual monoenergetic images (VMIs), effective atomic number, iodine map, and virtual non-contrast (VNC) images. VMIs were calculated from 80 and 140 kVp tube data at 10 kV each from 40-140 kV. Additionally, the effective atomic number, iodine map, and VNC images were reconstructed from the material decomposition process using water and iodine as the base material pair. RESULTS: In this study, 25 patients (eight with abscess and 17 with ascites) were included. No significant association was observed between the presence or absence of abscess and malignancy or surgical procedure. The intervention was performed in six of the eight patients with abscesses. In contrast, five of the 17 patients with postoperative ascites required intervention. A significant relationship was observed between the intervention and the presence of an abscess. Significant differences in C-reactive protein values and the incidence of fever were observed between the groups. Only VNC showed a significant difference between the groups. CONCLUSIONS: VNC using dual-energy CT could differentiate abscesses from postoperative fluid.

10.
Eur Radiol ; 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834786

RESUMO

OBJECTIVES: We aimed to develop and validate a radiomics nomogram based on dual-energy computed tomography (DECT) images and clinical features to classify the time since stroke (TSS), which could facilitate stroke decision-making. MATERIALS AND METHODS: This retrospective three-center study consecutively included 488 stroke patients who underwent DECT between August 2016 and August 2022. The eligible patients were divided into training, test, and validation cohorts according to the center. The patients were classified into two groups based on an estimated TSS threshold of ≤ 4.5 h. Virtual images optimized the visibility of early ischemic lesions with more CT attenuation. A total of 535 radiomics features were extracted from polyenergetic, iodine concentration, virtual monoenergetic, and non-contrast images reconstructed using DECT. Demographic factors were assessed to build a clinical model. A radiomics nomogram was a tool that the Rad score and clinical factors to classify the TSS using multivariate logistic regression analysis. Predictive performance was evaluated using receiver operating characteristic (ROC) analysis, and decision curve analysis (DCA) was used to compare the clinical utility and benefits of different models. RESULTS: Twelve features were used to build the radiomics model. The nomogram incorporating both clinical and radiomics features showed favorable predictive value for TSS. In the validation cohort, the nomogram showed a higher AUC than the radiomics-only and clinical-only models (AUC: 0.936 vs 0.905 vs 0.824). DCA demonstrated the clinical utility of the radiomics nomogram model. CONCLUSIONS: The DECT-based radiomics nomogram provides a promising approach to predicting the TSS of patients. CLINICAL RELEVANCE STATEMENT: The findings support the potential clinical use of DECT-based radiomics nomograms for predicting the TSS. KEY POINTS: Accurately determining the TSS onset is crucial in deciding a treatment approach. The radiomics-clinical nomogram showed the best performance for predicting the TSS. Using the developed model to identify patients at different times since stroke can facilitate individualized management.

11.
Quant Imaging Med Surg ; 14(6): 4155-4176, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38846275

RESUMO

Background: Dual-energy computed tomography (DECT) is a promising technique, which can provide unique capability for material quantification. The iterative reconstruction of material maps requires spectral information and its accuracy is affected by spectral mismatch. Simultaneously estimating the spectra and reconstructing material maps avoids extra workload on spectrum estimation and the negative impact of spectral mismatch. However, existing methods are not satisfactory in image detail preservation, edge retention, and convergence rate. The purpose of this paper was to mine the similarity between the reconstructed images and the material images to improve the imaging quality, and to design an effective iteration strategy to improve the convergence efficiency. Methods: The material-image subspace decomposition-based iterative reconstruction (MISD-IR) with spectrum estimation was proposed for DECT. MISD-IR is an optimized model combining spectral estimation and material reconstruction with fast convergence speed and promising noise suppression capability. We proposed to reconstruct the material maps based on extended simultaneous algebraic reconstruction techniques and estimation of the spectrum with model spectral. To stabilize the iteration and alleviate the influence of errors, we introduced a weighted proximal operator based on the block coordinate descending algorithm (WP-BCD). Furthermore, the reconstructed computed tomography (CT) images were introduced to suppress the noise based on subspace decomposition, which relies on non-local regularization to prevent noise accumulation. Results: In numerical experiments, the results of MISD-IR were closer to the ground truth compared with other methods. In real scanning data experiments, the results of MISD-IR showed sharper edges and details. Compared with other one-step iterative methods in the experiment, the running time of MISD-IR was reduced by 75%. Conclusions: The proposed MISD-IR can achieve accurate material decomposition (MD) without known energy spectrum in advance, and has good retention of image edges and details. Compared with other one-step iterative methods, it has high convergence efficiency.

12.
Quant Imaging Med Surg ; 14(6): 4041-4053, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38846294

RESUMO

Background: The technological innovation of fast kilovoltage (KV)-switching dual-energy computed tomography (DECT) has enabled the accurate measurement of vertebral bone density; however, it does not account for the effects of abdominal fat and ribs on the vertebral body. In our study, a European spine phantom (ESP) was used to establish an abdominal phantom for normal weight and obese people, and to explore the best scanning parameters for DECT to measure the bone mineral density (BMD) of the human lumbar spine. Methods: Revolution CT was used to conduct energy spectrum scanning for each body mode. A total of 20 sets of energy spectrum scans was conducted and each set of conditions was scanned 10 times. The data conformed to a normal distribution, and the differences between the measured and actual values of ESP L1-3 vertebrae were compared using a one-sample t-test, and quantitative data were described by x ¯ ± s . A P value <0.05 was considered statistically significant. Relative error (RE) and root mean square error (RMSE) of BMD measurements were calculated for different scanning conditions in normal and obese populations. Results: When simulating the upper abdominal condition (L1-2 level, fat area 140 cm2, with rib influence) in a normal weight population, there was no statistical difference (P>0.05) in BMD measurements for each vertebra at 0.8 s/rotation (rot) with different tube currents, the smallest RE at 0.8 s/rot, 190 mA condition, and the smallest RMSE for L1 and 2 vertebral BMD measurements at 190 mA; when simulating the abdominal condition at the L4 level in a normal weight population (fat area of 240 cm2, no rib influence), there were no statistical differences between the measurements at 0.8 s/rot, 190 and 275 mA conditions (P>0.05), and the RE and RMSE in the 190 mA condition was smaller than that in the 275 mA condition. Simulating the upper abdominal condition in the obese population (L1-2 level, fat area 340 cm2, with rib influence), there were no statistical difference between the measurements in the 0.8 s/rot, 315 and 355 mA conditions (P>0.05), the RE and RMSE in the 315 mA condition was less than those in the 355 mA; simulated obese abdominal condition at the L4 level in the population (fat area 450 cm2, no rib influence) resulted in 0.8 s/rot, no statistical difference in measurements between 315 mA (P>0.05), RE in 315 mA conditions were L1: 3.75%, L2: -1.06%, L3: 0.42%, and the RMSE under 315 mA condition were L1: 2.13, L2: 1.21, L3: 1.66. Conclusions: When using Revolution CT to measure lumbar spine bone density, 0.8 s/rot at 190 mA may be the best scanning parameter for a normal weight population, and 0.8 s/rot at 315 mA may be the best scanning parameter for an obese population.

13.
Eur Radiol ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38856781

RESUMO

OBJECTIVES: Our study comprised a single-center retrospective in vitro correlation between spectral properties, namely ρ/Z values, derived from scanning blood samples using dual-energy computed tomography (DECT) with the corresponding laboratory hemoglobin/hematocrit (Hb/Hct) levels and assessed the potential in anemia-detection. METHODS: DECT of 813 patient blood samples from 465 women and 348 men was conducted using a standardized scan protocol. Electron density relative to water (ρ or rho), effective atomic number (Zeff), and CT attenuation (Hounsfield unit) were measured. RESULTS: Positive correlation with the Hb/Hct was shown for ρ (r-values 0.37-0.49) and attenuation (r-values 0.59-0.83) while no correlation was observed for Zeff (r-values -0.04 to 0.08). Significant differences in attenuation and ρ values were detected for blood samples with and without anemia in both genders (p value < 0.001) with area under the curve ranging from 0.7 to 0.95. Depending on the respective CT parameters, various cutoff values for CT-based anemia detection could be determined. CONCLUSION: In summary, our study investigated the correlation between DECT measurements and Hb/Hct levels, emphasizing novel aspects of ρ and Zeff values. Assuming that quantitative changes in the number of hemoglobin proteins might alter the mean Zeff values, the results of our study show that there is no measurable correlation on the atomic level using DECT. We established a positive in vitro correlation between Hb/Hct values and ρ. Nevertheless, attenuation emerged as the most strongly correlated parameter with identifiable cutoff values, highlighting its preference for CT-based anemia detection. CLINICAL RELEVANCE STATEMENT: By scanning multiple blood samples with dual-energy CT scans and comparing the measurements with standard laboratory blood tests, we were able to underscore the potential of CT-based anemia detection and its advantages in clinical practice. KEY POINTS: Prior in vivo studies have found a correlation between aortic blood pool and measured hemoglobin and hematocrit. Hemoglobin and hematocrit correlated with electron density relative to water and attenuation but not Zeff. Dual-energy CT has the potential for additional clinical benefits, such as CT-based anemia detection.

14.
Diagnostics (Basel) ; 14(12)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38928639

RESUMO

The field of computed tomography (CT), which is a basic diagnostic tool in clinical practice, has recently undergone rapid technological advances. These include the evolution of dual-energy CT (DECT) and development of photon-counting computed tomography (PCCT). DECT enables the acquisition of CT images at two different energy spectra, which allows for the differentiation of certain materials, mainly calcium and iodine. PCCT is a recent technology that enables a scanner to quantify the energy of each photon gathered by the detector. This method gives the possibility to decrease the radiation dose and increase the spatial and temporal resolutions of scans. Both of these techniques have found a wide range of applications in radiology, including vascular studies. In this narrative review, the authors present the principles of DECT and PCCT, outline their advantages and drawbacks, and briefly discuss the application of these methods in vascular radiology.

15.
Nanomedicine ; 61: 102765, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38942131

RESUMO

In equine medicine, assisted bone regeneration, including use of biomaterial substitutes like hydroxyapatite (HAP), is crucial for addressing bone defects. To follow-up on the outcome of HAP-based bone defect treatment, the advancement in quantified diagnostic imaging protocols is needed. This study aimed to quantify and compare the radiological properties of the HAP graft and natural equine bone using Magnetic Resonance (MR) and Computed Tomography (CT), both Single (SECT) and Dual Energy (DECT). SECT and DECT, allow for the differentiation of three HAP grain sizes, by progressive increase in relative density (RD). SECT, DECT, and MR enable the differentiation between natural cortical bone and synthetic HAP graft by augmentation in Effective Z and material density (MD) in HAP/Water, Calcium/Water, and Water/Calcium reconstructions, alongside the reduction in T2 relaxation time. The proposed quantification provided valuable radiological insights into the composition of HAP grafts, which may be useful in follow-up bone defect treatment.

16.
Radiol Med ; 129(7): 967-976, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38869829

RESUMO

PURPOSE: To evaluate the efficacy of volumetric CT attenuation-based parameters obtained through automated 3D organ segmentation on virtual non-contrast (VNC) images from dual-energy CT (DECT) for assessing hepatic steatosis. MATERIALS AND METHODS: This retrospective study included living liver donor candidates having liver DECT and MRI-determined proton density fat fraction (PDFF) assessments. Employing a 3D deep learning algorithm, the liver and spleen were automatically segmented from VNC images (derived from contrast-enhanced DECT scans) and true non-contrast (TNC) images, respectively. Mean volumetric CT attenuation values of each segmented liver (L) and spleen (S) were measured, allowing for liver attenuation index (LAI) calculation, defined as L minus S. Agreements of VNC and TNC parameters for hepatic steatosis, i.e., L and LAI, were assessed using intraclass correlation coefficients (ICC). Correlations between VNC parameters and MRI-PDFF values were assessed using the Pearson's correlation coefficient. Their performance to identify MRI-PDFF ≥ 5% and ≥ 10% was evaluated using receiver operating characteristic (ROC) curve analysis. RESULTS: Of 252 participants, 56 (22.2%) and 16 (6.3%) had hepatic steatosis with MRI-PDFF ≥ 5% and ≥ 10%, respectively. LVNC and LAIVNC showed excellent agreement with LTNC and LAITNC (ICC = 0.957 and 0.968) and significant correlations with MRI-PDFF values (r = - 0.585 and - 0.588, Ps < 0.001). LVNC and LAIVNC exhibited areas under the ROC curve of 0.795 and 0.806 for MRI-PDFF ≥ 5%; and 0.916 and 0.932, for MRI-PDFF ≥ 10%, respectively. CONCLUSION: Volumetric CT attenuation-based parameters from VNC images generated by DECT, via automated 3D segmentation of the liver and spleen, have potential for opportunistic hepatic steatosis screening, as an alternative to TNC images.


Assuntos
Fígado Gorduroso , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Masculino , Feminino , Fígado Gorduroso/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Pessoa de Meia-Idade , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Doadores Vivos , Fígado/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Baço/diagnóstico por imagem , Curva ROC
17.
Br J Radiol ; 97(1160): 1467-1475, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38870535

RESUMO

OBJECTIVES: Microvascular invasion (MVI) is a recognized biomarker associated with poorer prognosis in patients with hepatocellular carcinoma. Dual-energy computed tomography (DECT) is a highly sensitive technique that can determine the iodine concentration (IC) in tumour and provide an indirect evaluation of internal microcirculatory perfusion. This study aimed to assess whether the combination of DECT with laboratory data can improve preoperative MVI prediction. METHODS: This retrospective study enrolled 119 patients who underwent DECT liver angiography at 2 medical centres preoperatively. To compare DECT parameters and laboratory findings between MVI-negative and MVI-positive groups, Mann-Whitney U test was used. Additionally, principal component analysis (PCA) was conducted to determine fundamental components. Mann-Whitney U test was applied to determine whether the principal component (PC) scores varied across MVI groups. Finally, a general linear classifier was used to assess the classification ability of each PC score. RESULTS: Significant differences were noted (P < .05) in alpha-fetoprotein (AFP) level, normalized arterial phase IC, and normalized portal phase IC between the MVI groups in the primary and validation datasets. The PC1-PC4 accounted for 67.9% of the variance in the primary dataset, with loadings of 24.1%, 16%, 15.4%, and 12.4%, respectively. In both primary and validation datasets, PC3 and PC4 were significantly different across MVI groups, with area under the curve values of 0.8410 and 0.8373, respectively. CONCLUSIONS: The recombination of DECT IC and laboratory features based on varying factor loadings can well predict MVI preoperatively. ADVANCES IN KNOWLEDGE: Utilizing PCA, the amalgamation of DECT IC and laboratory features, considering diverse factor loadings, showed substantial promise in accurately classifying MVI. There have been limited endeavours to establish such a combination, offering a novel paradigm for comprehending data in related research endeavours.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Invasividade Neoplásica , Tomografia Computadorizada por Raios X , Humanos , Masculino , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/irrigação sanguínea , Feminino , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/irrigação sanguínea , Estudos Retrospectivos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Iodo , Microvasos/diagnóstico por imagem , Microvasos/patologia , Adulto , alfa-Fetoproteínas/análise , alfa-Fetoproteínas/metabolismo
18.
World J Radiol ; 16(4): 82-93, 2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38690548

RESUMO

BACKGROUND: Currently, the differentiation of jaw tumors is mainly based on the lesion's morphology rather than the enhancement characteristics, which are important in the differentiation of neoplasms across the body. There is a paucity of literature on the enhancement characteristics of jaw tumors. This is mainly because, even though computed tomography (CT) is used to evaluate these lesions, they are often imaged without intravenous contrast. This study hypothesised that the enhancement characteristics of the solid component of jaw tumors can aid in the differentiation of these lesions in addition to their morphology by dual-energy CT, therefore improving the ability to differentiate between various pathologies. AIM: To evaluate the role of contrast enhancement and dual-energy quantitative parameters in CT in the differentiation of jaw tumors. METHODS: Fifty-seven patients with jaw tumors underwent contrast-enhanced dual-energy CT. Morphological analysis of the tumor, including the enhancing solid component, was done, followed by quantitative analysis of iodine concentration (IC), water concentration (WC), HU, and normalized IC. The study population was divided into four subgroups based on histopathological analysis-central giant cell granuloma (CGCG), ameloblastoma, odontogenic keratocyst (OKC), and other jaw tumors. A one-way ANOVA test for parametric variables and the Kruskal-Wallis test for non-parametric variables were used. If significant differences were found, a series of independent t-tests or Mann-Whitney U tests were used. RESULTS: Ameloblastoma was the most common pathology (n = 20), followed by CGCG (n = 11) and OKC. CGCG showed a higher mean concentration of all quantitative parameters than ameloblastomas (P < 0.05). An IC threshold of 31.35 × 100 µg/cm3 had the maximum sensitivity (81.8%) and specificity (65%). Between ameloblastomas and OKC, the former showed a higher mean concentration of all quantitative parameters (P < 0.001), however when comparing unilocular ameloblastomas with OKCs, the latter showed significantly higher WC. Also, ameloblastoma had a higher IC and lower WC compared to "other jaw tumors" group. CONCLUSION: Enhancement characteristics of solid components combined with dual-energy parameters offer a more precise way to differentiate between jaw tumors.

19.
Acad Radiol ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38806373

RESUMO

RATIONALE AND OBJECTIVES: Within global sustainable resource management efforts, reducing healthcare energy consumption is of public concern. This study aims to analyze the energy consumption of three Dual-Energy computed tomography (DECT) scanners and to predict the power consumption based on scan acquisition parameters. MATERIALS AND METHODS: This study consisted of two parts assessing three DECT scanners: one Dual-Source and two Single-Source DECT. In Part A, the energy consumption for various single- and DECT scans with different acquisition parameters using a chest phantom was measured. The measurements were compared to the calculated power consumption. In Part B, the energy consumption baselines during nonutilization states of the DECT devices: idle (ready to scan), low-power (incomplete shutdown), and system-off mode (complete shutdown) were measured. Descriptive statistics were used. RESULTS: The phantom study revealed a positive correlation between measured and calculated energy consumption (r2 =0.82), except for single-source split-filter DECT acquisitions, indicating a relationship between scan parameters and energy consumption. The baseline study results showed a mean energy consumption of 2.6kWh/hour ± 1.34kWh in idle, 0.89kWh/hour ± 0.42kWh in low-power, and < 0.01kWh/hour ± 0.003kWh in the system-off state. The potential total annual CO2 savings for the assessed DECT scanners amounted to 3767kg CO2 (low power) and 5868kg CO2 (system off) compared to the idle state. Time-related calculations indicated energy savings starting after 5 min in low-power- and after 2 min in the system-off state. Therefore, switching off the scanner, even during shorter periods of non-utilization, can be efficient. CONCLUSION: Our results emphasize a positive correlation between scan parameters and energy consumption in DECT. Complete shutdown of DECT devices can have a significant ecological-economic impact.

20.
Radiol Case Rep ; 19(7): 2879-2885, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38706813

RESUMO

We report a case wherein adrenal function remained preserved despite bilateral adrenal infarction, as evidenced by dual-energy computed tomography (DECT) iodine density images. The patient was a 37-year-old man with a history of antiphospholipid syndrome concomitant with systemic lupus erythematosus. The patient underwent contrast-enhanced DECT, which revealed bilateral adrenal infarction. Laboratory tests revealed preserved adrenal function. On the iodine density images, the infarcted and noninfarcted areas in the adrenal glands were visually different. The volume of the non-infarcted area was 8.9 mL, which was 41% of the total adrenal volume. DECT may be a useful complementary tool for assessing the preservation of adrenal function.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA