Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Cureus ; 16(7): e65051, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39165436

RESUMO

INTRODUCTION: Ankle fractures associated with disruption of the syndesmotic complex could potentially have poorer outcomes if missed or malreduced at the time of surgery. Favourable results have been reported for the suture button (SB) technique and may provide advantages over standard screw fixation of the syndesmosis, although this remains the gold standard method in many units. AIM: To compare the outcomes of syndesmotic screws (SS) with SB fixation of the syndesmosis during ankle fracture fixation at a high-volume orthopaedic department of a Scotland trauma unit. METHOD:  A cross-sectional, retrospective study looking at ankle fracture fixations was undertaken at the Clyde Trauma Unit, Paisley. Relevant information was obtained from electronic patient records for 457 ankle fracture patients between August 2019 and February 2022 and followed up for six months. The digital patient archive system (PACS) was used for evaluating radiographs. Patients were divided into two groups depending on whether they had an SS or SB fixation of their syndesmosis. We focused on the surgical and radiological outcomes following syndesmotic fixation as no functional scores following surgery were conducted on the patients. RESULT: Out of the entire study group, 26.3% (120/457 patients) required syndesmotic fixation. Within the syndesmotic fixation group, 70.8% (85/120 patients) underwent SS fixation, and 29.2% (35/120 patients) had an SB fixation. Both groups were statistically well-matched. Additionally, 21.1% (18/85) of SS fixation went on to have a second surgical procedure (four fixation failures, five planned removals, five for pain/stiffness, two infections, and two metalwork breakage/migration), whereas 8.6% (3/35) of the SB fixation group had a secondary procedure - two for fixation failures and one for infection. CONCLUSION: We reported a higher incidence of associated syndesmotic injury in our series of 457 ankle fractures than previously described. There were significantly fewer sequelae in the SB group compared to the SS fixation group (P = 0.0464). Although we did not observe a statistically significant difference in the rate of reoperation (P = 0.1184), this is likely due to the small numbers in the SB group. Our study suggests that SB fixation may be associated with a lower rate of reoperation for post-op complications such as metalwork failure, pain, and stiffness (21.1% SS vs 8.6% SB). Regardless of the fixation method used, accurate reduction of the ankle mortice and syndesmosis is a key step to a successful surgical outcome.

2.
Sci Rep ; 14(1): 19214, 2024 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-39160241

RESUMO

In recent years, finite element analysis (FEA) has been instrumental in comparing the biomechanical stability of various implants for femur fracture treatment and in studying the advantages and disadvantages of different surgical techniques. This analysis has proven helpful for enhancing clinical treatment outcomes. Therefore, this study aimed to numerically analyze fixed stability according to location using FEA. In this study, a virtual finite element model was created based on a clinically anatomically reduced patient. It incorporated positive and negative support derived from intramedullary and extramedullary reduction from the anteroposterior (AP) view and neutral support from the lateral view. The generated model was analyzed to understand the biomechanical behavior occurring in each region under applied physiological loads. The simulation results of this study showed that the average von Mises stress (AVMS) of the nail when performing intramedullary reduction for femoral fixation was 187% of the anatomical reduction and 171% of the extramedullary reduction, and individually up to 2.5 times higher. In other words, intramedullary reduction had a very high possibility of fixation failure compared to other reduction methods. This risk is amplified significantly, especially in situations where bone strength is compromised due to factors such as old age or osteoporosis, which substantially affects the stability of fixation. Extramedullary reduction, when appropriately positioned, demonstrates greater stability than anatomical reduction. It exhibits stable fixation even in scenarios with diminished bone strength. In instances in which the bone density was low in the support position, as observed in the lateral view, the AVMS on the nail appeared to be relatively low, particularly in cases of positive support. Additionally, the femur experienced lower equivalent stress only in the extramedullary reduction-negative position. Moreover, by comparing different reduction methods and bone stiffness values using the same femoral shape, this study offers insights into the selection of appropriate reduction methods. These insights could significantly inform decision making regarding surgical strategies for intertrochanteric fractures.


Assuntos
Análise de Elementos Finitos , Fixação Interna de Fraturas , Fraturas do Quadril , Humanos , Fixação Interna de Fraturas/métodos , Fraturas do Quadril/cirurgia , Fraturas do Quadril/fisiopatologia , Fenômenos Biomecânicos , Fixação Intramedular de Fraturas/métodos , Fêmur/cirurgia , Estresse Mecânico , Pinos Ortopédicos , Masculino , Idoso
3.
Arch Orthop Trauma Surg ; 144(1): 121-130, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37698623

RESUMO

BACKGROUND: Surgical treatment of midshaft clavicle fractures is associated with quick recovery and low risk of non-union. However, fixation failure may occur in case of severe comminution fractures. Moreover, clinical outcomes may be affected when clavicle fractures occur in combination with other injuries, particularly those involving the lower extremities, as the use of crutches or walkers may hinder the process of rehabilitation by adding strain on the acromioclavicular (AC) joint, resulting in possible fixation failure. This study aims to identify risk factors for fixation failure of midshaft clavicle fractures and elucidate the role of combined fractures in treatment outcomes. METHODS: This study included patients diagnosed with midshaft clavicle fractures who underwent initial surgery between January 2012 and November 2021 at a designated regional trauma center hospital. Retrospective evaluation of fixation failure was carried out in 352 patients with midshaft clavicle fractures using standard clinical evaluation protocols and conventional radiographs. The prevalence of fixation failure and the effects of several demographic variables on the risk of fixation failure and non-union were examined. Multivariate logistic regression analysis was carried out to identify independent risk factors for fixation failure. RESULTS: Fixation failure occurred in 40 patients (11.4%). Multivariate analysis identified comminution [odds ratio (OR) 3.532, p value = 0.003, 95% confidence interval (CI) 1.55-8.05)] and fewer number of screws (OR 0.223, p value = 0.022, 95% CI 0.06-0.80) as risk factors for fixation failure. Surgical techniques using wire cerclage reduced the chances of fixation failure in comminuted fractures (OR 0.63, p value = 0.033, 95% CI 0.05-0.80). Combined fractures that required rehabilitation using walkers or crutches increased the risk of non-union (OR 19.043, p value = 0.032, 95% CI 1.28-282.46). CONCLUSIONS: Additional fixation of comminuted fractures using cerclage can reduce the risk of treatment failure, while multiple fractures or rehabilitation for ambulation increases the risk of the same. LEVEL OF EVIDENCE: III.


Assuntos
Fraturas Ósseas , Fraturas Cominutivas , Fraturas Múltiplas , Humanos , Estudos Retrospectivos , Fraturas Cominutivas/cirurgia , Fraturas Múltiplas/etiologia , Clavícula/cirurgia , Clavícula/lesões , Fraturas Ósseas/terapia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Placas Ósseas , Resultado do Tratamento
4.
J Hand Surg Eur Vol ; 49(3): 366-371, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37310030

RESUMO

Anterior locking plate fixation of the distal radius is a common procedure with reliable results. Failure of fixation is sometimes seen. The aim of the present study was to identify the reasons for failure. In total, 517 cases met the study inclusion criteria. Of them, 23 cases had failure of fixation (4.4%). Failure analysis generated qualitative data. Subsequent thematic analysis identified the primary mode of failure and contributing factors. Primary modes were identified as failure to support all key fracture fragments (n = 20), wrong choice of implant (n = 1), failure of union (n = 1) and poor bone quality (n = 1). Contributing factors were errors in plate positioning, fracture reduction, implant selection and screw configuration, as well as fracture pattern complexity and poor bone quality. Most failed fixations had a primary mode and two or three contributing factors. Overall anterior plating is reliable with a low rate of surgical failure. Knowledge of failure modes will aid operative planning and prevent failure.Level of evidence: V.


Assuntos
Fraturas do Rádio , Rádio (Anatomia) , Humanos , Rádio (Anatomia)/cirurgia , Fraturas do Rádio/cirurgia , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Placas Ósseas
5.
SICOT J ; 9: 28, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37737668

RESUMO

INTRODUCTION: Lag screw cut-out is a serious complication of dynamic hip screw fixation of trochanteric hip fractures. The lag screw position has been acknowledged as one of the important factors affecting the lag screw cut-out. We propose a modification of the Tip Apex Distance (TAD) and hypothesise that it could improve the reliability of predicting lag screws cut-out in these injuries. MATERIALS AND METHODS: A retrospective study was conducted for hip fracture entries in the period from Jan 2018 to July 2022. A hundred and nine patients were suitable for the final analysis. The modified TAD was measured in millimetres based on the sum of the traditional TAD in the lateral view and the net value of two distances in the AP view, the first distance is from the tip of the lag screw to the opposite point on the femoral head along the axis of the lag screw while the second distance is from that point to the femoral head apex. The first distance is a positive value, whereas the second distance is positive if the lag screw is superior and negative if inferior. A receiver operating characteristic curve was used to evaluate the reliability of the different parameters assessing the lag screw position within the femoral head. RESULTS: Reduction quality, fracture pattern as per the AO/OTA classification, TAD, Calcar Referenced TAD, Axis Blade Angle, Parker's ration in the AP view, Cleveland Zone 1, and modified TAD were statistically associated with lag screw cut-out. Among the tested parameters, the modified TAD had 90.1% sensitivity and 90.9% specificity for lag screw cut-out at a cut-off value of 25 mm with a P-value < 0.001. CONCLUSION: The modified TAD had the highest reliability in the prediction of lag screw cut-out. A value ≤ 25 mm could potentially protect against lag screw cut-out in trochanteric hip fractures.

6.
Cureus ; 15(7): e41349, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37546044

RESUMO

Background For successful internal fixation for femoral neck fracture, the sliding mechanism of the screw is important because it can induce inter-fragmental compression. The thread should penetrate the fracture line and be located within the proximal fragment. If screw thread engagement is incomplete and a part of the thread remains within the distal fragment, the screw sliding can be disturbed, potentially leading to fixation failure. We hypothesized that screw thread in the fracture is a risk of fixation failure. Methods We studied 133 hips that underwent internal fixation for femoral neck fracture using dual sliding and compression screws (DSCS) with 20 mm threads. The existence of incomplete thread engagement and fixation failure (cut out, perforation, pseudoarthrosis, or femoral neck shortening) were evaluated on anteroposterior hip radiography postoperatively. The distances from the thread end to the fracture line, screw head to the femoral head cortex, and femoral head diameter were measured to analyze their relationships with any incomplete thread engagement and fixation failure. Differences in evaluation data were assessed using Fisher's exact test, Student's t-test, and receiver operating characteristic (ROC) analysis. Results Forty-six cases had at least one screw with incomplete thread engagement, and the other 87 hips had a complete engagement. The failure rate in the group of hips with incomplete thread engagement was significantly higher (7/46, 15.2%) than that in the group of hips with complete thread engagement (3/87, 3.4%) (P = 0.032). Incomplete thread engagement was found in 59 out of 266 screws (22.2%), and a femoral head ≤ 43.9 mm in diameter was associated with an increased risk of incomplete thread engagement. Most incomplete thread engagement screws (81.4%) had < 5 mm thread length within the distal fragment. Conclusion A partially threaded screw is a significant risk of fixation failure after internal fixation for a femoral neck fracture. The smaller femoral head diameter increases the possibility of incomplete thread engagement. Shortening the thread length by 5 mm may help to avoid incomplete thread engagement.

7.
BMC Musculoskelet Disord ; 24(1): 674, 2023 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-37620843

RESUMO

OBJECTIVE: Analysis of the risk factors affecting hip function and complications after femoral neck system (FNS) surgery for femoral neck fractures is of great significance for improving the procedure's efficacy. METHODS: The data of patients with femoral neck fractures who underwent FNS surgery in our hospital between October 2019 and October 2020 were retrospectively analyzed. Age, gender, time from injury to operation, fracture classification, operation time, fracture reduction, and postoperative weight-bearing time information were set as potential factors that may affect the results. Hip Harris scores were performed at 12 months postoperatively, and postoperative complication data (e.g., femoral head necrosis, nonunion, and femoral neck shortness) were collected. The risk factors affecting hip function and complications after FNS surgery were predicted using linear and logistic regression analyses. RESULTS: A total of 69 cases of femoral neck fracture were included, with an average age of 56.09 ± 11.50 years. The linear analysis demonstrated that the age and fracture type of the patients were the risk factors affecting the Harris score of the hip joint after FNS surgery. Older patients with displaced femoral neck fractures had an inferior postoperative hip function. In addition, fracture type, reduction of the femoral neck, and postoperative weight-bearing significantly impacted postoperative complications. Displaced fractures, negative fixation, and premature weight-bearing (< 6 weeks) were risk factors for postoperative complications. The Harris score of patients with a shortened femoral neck in the included cases was not significantly different from that of patients without shortening (P = 0.25). CONCLUSIONS: Advanced age and fracture type are important evaluation indicators of the Harris score after FNS internal fixation of femoral neck fractures in young patients. Fracture type, fracture reduction, and postoperative weight-bearing time are risk factors for complications after FNS.


Assuntos
Fraturas do Colo Femoral , Colo do Fêmur , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Fraturas do Colo Femoral/cirurgia , Fatores de Risco , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia
8.
Global Spine J ; : 21925682231195954, 2023 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-37562976

RESUMO

STUDY DESIGN: Retrospective cohort study. OBJECTIVES: This study aimed to investigate the failure of the caudal end of lumbar posterior fixation in terms of pre-operative and post-operative spinopelvic parameters, correction performed, demographic and clinical data. METHODS: The lumbar, thoraco-lumbar and lumbo-sacral posterior fixations performed with pedicle screws and rods in 2017-2019 were retrospectively analyzed. As 81% failures occurred within 4 years, an observational period of 4 years was chosen. The revision surgeries due to the failure in the caudal end were collected in the junctional group. Fixations which have not failed were gathered in the control group. The main spinopelvic parameters were measured for each patient on standing lateral radiographs with the software Surgimap. Demographic and clinical data were extracted for both groups. RESULTS: Among the 457 patients who met the inclusion criteria, the junctional group included 101 patients, who required a revision surgery. The control group collected 356 primary fixations. The two most common causes of revision surgeries were screws pullout (57 cases) and rod breakage (53 cases). SVA, PT, LL, PI-LL and TPA differed significantly between the two groups (P = .021 for LL, P < .0001 for all the others). The interaction between the two groups and the pre-operative and post-operative conditions was significant for PT, SS, LL, TK, PI-LL and TPA (P < .005). Sex and BMI did not affect the failure onset. CONCLUSIONS: Mechanical failure is more likely to occur in patients older than 40 years with a thoraco-lumbar fixation where PT, PI-LL and TPA were not properly restored.

9.
Clin Interv Aging ; 18: 485-493, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37008803

RESUMO

Purpose: Dual-energy X-ray absorptiometry (DXA) is commonly used for evaluation of bone mineral density before spinal surgery, but frequently leads to overestimation in degenerative spinal diseases due to osteoproliferation factors. We introduce a novel method to compare the predictive ability of Hounsfield Units (HU) and DXA methods to predict screw loosening after lumbar interbody fusion surgery in degenerative spinal diseases by measuring HU of pedicle screw trajectory on computed tomography (CT) images preoperatively. Patients and Methods: This retrospective study was conducted on patients who underwent posterior lumbar fusion surgery for degenerative diseases. CT HUs measurement was performed using medical imaging software, including the cancellous region on cross-sections of the vertebral body and three-dimensional pedicle screw trajectory. Receiver operating characteristic (ROC) curve analyses were performed for the risk of pedicle screw loosening in association with the Hounsfield scale and preoperative BMD, and the area under the curve (AUC) and the cutoff values were calculated. Results: A total of 90 patients were enrolled and were divided into loosening (n = 33, 36.7%) and non-loosening groups (n = 57, 63.3%). No significant differences in age, gender, length of fixation and preoperative BMD were found between both groups. The loosening group showed lower CT HU values in the vertebral body and screw trajectory than the non-loosening group. Screw trajectory HU (ST-HU) exhibited a higher AUC value than vertebral body HU (B-HU). The cutoff values of B-HU and ST-HU were 160 and 110 HUs, respectively. Conclusion: Three-dimensional pedicle screw trajectory HU values yields a stronger predictive value than vertebral body HU values and BMD and may provide more guidance for surgery. The risk of screw loosening is significantly increased at ST-HU <110 or B-HU <160 at L5 segment.


Assuntos
Parafusos Pediculares , Doenças da Coluna Vertebral , Fusão Vertebral , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Estudos Retrospectivos , Densidade Óssea , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos
10.
Zhongguo Gu Shang ; 36(3): 242-6, 2023 Mar 25.
Artigo em Chinês | MEDLINE | ID: mdl-36946016

RESUMO

OBJECTIVE: To investigate the relationship between the shape of the lateral wall and the early failure of internal fixation in the fracture of the femoral trochanteric region(FFT). METHODS: Total 295 patients with femoral trochanteric fracture underwent internal fixation from January 2015 to January 2020 were selected. The patients were divided into two groups according to whether there was early internal fixation failure after surgery, 19 patients in the failure group and 276 patients in the normal group. Gender, affected side, age, AO classification, body mass index(BMI), preoperative hemoglobin, X-ray measurement of lower lateral wall thickness, preoperative internal diseases, intraoperative blood loss, postoperative tip apex distance(TAD), postoperative neck shaft angle, operation time and other data were compared between two groups. The shape of the lateral wall was compared between two groups, and the correlation between the shape of the lateral wall and the early internal fixation failure of femoral trochanteric fracture was analyzed. RESULTS: All patients were followed up for more than 1 year. There was no significant difference between two groups in terms of intraoperative blood loss, operation time, postoperative TAD, and postoperative neck shaft angle(P>0.05). At the latest follow-up, the visual anaglue scale (VAS) of the failure group was higher than that of the normal group(P<0.01), and the Harris score of the failure group was lower than that of normal group(P<0.05). The receiver operator characteristic (ROC) curve between shape of lateral wall and failure of early internal fixation of femoral trochanteric fracture was drawn. The critical value of the midpoint lateral wall thickness was 16.5 mm, and the area under the ROC curve was 0.845;The critical value of average sidewall thickness was 16.5 mm, and the area under ROC curve was 0.838;The critical value of the axial area of the sidewall was 7.5 mm, and the area under the ROC curve was 0.826. CONCLUSION: The shape of the lateral femoral wall measured by CT could be used as a predictive factor for the early failure of internal fixation of femoral trochanteric fractures. For patients at risk, more reasonable surgical plans and postoperative preventive measures should be developed.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Resultado do Tratamento , Pinos Ortopédicos , Estudos Retrospectivos , Fraturas do Quadril/cirurgia , Fixação Interna de Fraturas
11.
Med Eng Phys ; 111: 103926, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36792233

RESUMO

BACKGROUND: The optimal technique for managing distal femur fixation failure remains inconclusive. The author studied the efficacy of a combined proximal humerus locking compression plate (LCP-PH) and 3.5 mm reconstruction plate (LCP-RP) by finite element (FE) analysis and retrospectively described the clinical outcomes of the present technique in such difficult circumstances. METHODS: Biomechanical study setting included FE models of the distal femur with remaining holes from previous distal femur LCP (LCP-DF) fixation stabilized with three different constructs i.e., LCP-DF alone, LCP-DF-and-LCP-RP, as well as LCP-PH-and-LCP-RP. All settings were analyzed by using FE under physiological loads. Regarding the clinical series, the outcomes of 8 LCP-DF fixation failures operated on by the present technique were retrospectively reviewed. RESULTS: High Implant stress of 911.2 MPa and elastic strain at fracture site of 200.8 µÉ› were found when stabilized with LCP-DF. The constructs of LCP-DF-and-LCP-RP, and LCP-PH-and-LCP-RP presented lower implant stress compared to LCP-DF, 511.5, and 617.5 MPa, respectively. The elastic strain of both dual plating constructs was also 4-5 times lower than LCP-DF and differed from each other by approximately 10 µÉ›. Regarding the clinical series, bony consolidation was achieved in all cases with a mean duration of 28.5 weeks (range 24-36). An average ROM of the affected knee was 115° (range 105-140). Regarding the KSS, 1 was determined to be excellent and 7 to be good. CONCLUSION: By the biomechanical analysis and the clinical results, the construct of LCP-PH-and-LCP-RP could be an effective technique for revision surgery of LCP-DF fixation failure.


Assuntos
Fêmur , Fixação Interna de Fraturas , Análise de Elementos Finitos , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Fêmur/cirurgia , Placas Ósseas , Fenômenos Biomecânicos
12.
Unfallchirurgie (Heidelb) ; 126(3): 238-243, 2023 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-35476023

RESUMO

Following fixation of a trochanteric femoral fracture with a TFNA© and despite correct fracture reduction and fixation, a 96-year-old patient suffered a complete cut-in, i.e. a medialization of the entire femoral neck blade through the nail into the hip joint. Against the background of implant development and current literature, this increasingly frequent type of complication is described and distinguished from other fixation failures such as the cut-out. Attempts to explain this phenomenon as well as research options are presented and a pragmatic approach to avoid this problem is outlined.


Assuntos
Colo do Fêmur , Fraturas do Quadril , Humanos , Idoso de 80 Anos ou mais , Pinos Ortopédicos , Fraturas do Quadril/diagnóstico por imagem , Fixação Interna de Fraturas , Articulação do Quadril
13.
J Neurosurg Spine ; 38(1): 91-97, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36029261

RESUMO

OBJECTIVE: There is a paucity of literature on pelvic fixation failure after adult spine surgery in the early postoperative period. The purpose of this study was to determine the incidence of acute pelvic fixation failure in a large single-center study and to describe the lessons learned. METHODS: The authors performed a retrospective review of adult (≥ 18 years old) patients who underwent spinal fusion with pelvic fixation (iliac, S2-alar-iliac [S2AI] screws) at a single academic medical center between 2015 and 2020. All patients had a minimum of 3 instrumented levels. The minimum follow-up was 6 months after the index spine surgery. Patients with prior pelvic fixation were excluded. Acute pelvic fixation failure was defined as revision of the pelvic screws within 6 months of the primary surgery. Patient demographics and operative, radiographic, and rod/screw parameters were collected. All rods were cobalt-chrome. All iliac and S2AI screws were closed-headed screws. RESULTS: In 358 patients, the mean age was 59.5 ± 13.6 years, and 64.0% (n = 229) were female. The mean number of instrumented levels was 11.5 ± 5.5, and 79.1% (n = 283) had ≥ 6 levels fused. Three-column osteotomies were performed in 14.2% (n = 51) of patients, and 74.6% (n = 267) had an L5-S1 interbody fusion. The mean diameter/length of pelvic screws was 8.5/86.6 mm. The mean number of pelvic screws was 2.2 ± 0.5, the mean rod diameter was 6.0 ± 0 mm, and 78.5% (n = 281) had > 2 rods crossing the lumbopelvic junction. Accessory rods extended to S1 (32.7%, n = 117) or S2/ilium (45.8%, n = 164). Acute pelvic fixation failure occurred in 1 patient (0.3%); this individual had a broken S2AI screw near the head-neck junction. This 76-year-old woman with degenerative lumbar scoliosis and chronic lumbosacral zone 1 fracture nonunion had undergone posterior instrumented fusion from T10 to pelvis with bilateral S2AI screws (8.5 × 90 mm); i.e., transforaminal lumbar interbody fusion L4-S1. The patient had persistent left buttock pain postoperatively, with radiographically confirmed breakage of the left S2AI screw 68 days after surgery. Revision included instrumentation removal at L2-pelvis and a total of 4 pelvic screws. CONCLUSIONS: The acute pelvic fixation failure rate was exceedingly low in adult spine surgery. This rate may be the result of multiple factors including the preference for multirod (> 2), closed-headed pelvic screw constructs in which large-diameter long screws are used. Increasing the number of rods and screws at the lumbopelvic junction may be important factors to consider, especially for patients with high risk for nonunion.


Assuntos
Escoliose , Fusão Vertebral , Humanos , Adulto , Feminino , Pessoa de Meia-Idade , Idoso , Adolescente , Masculino , Parafusos Ósseos , Pelve/cirurgia , Ílio/cirurgia , Escoliose/cirurgia , Osteotomia , Fusão Vertebral/efeitos adversos , Sacro/diagnóstico por imagem , Sacro/cirurgia
14.
J Neurosurg Spine ; 38(2): 208-216, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36242579

RESUMO

OBJECTIVE: The purpose of this study was to determine the incidence, mechanism, and potential protective strategies for pelvic fixation failure (PFF) within 2 years after adult spinal deformity (ASD) surgery. METHODS: Data for ASD patients (age ≥ 18 years, minimum of six instrumented levels) with pelvic fixation (S2-alar-iliac [S2AI] and/or iliac screws) with a minimum 2-year follow-up were consecutively collected (2015-2019). Patients with prior pelvic fixation were excluded. PFF was defined as any revision to pelvic screws, which may include broken rods across the lumbosacral junction requiring revision to pelvic screws, pseudarthrosis across the lumbosacral junction requiring revision to pelvic screws, a broken or loose pelvic screw, or sacral/iliac fracture. Patient information including demographic data and health history (age, sex, BMI, smoking status, American Society of Anesthesiologists score, osteoporosis), operative (total instrumented levels [TIL], three-column osteotomy [3CO], interbody fusion), screw (iliac, S2AI, length, diameter), rod (diameter, kickstand), rod pattern (number crossing lumbopelvic junction, lowest instrumented vertebra [LIV] of accessory rod[s], lateral connectors, dual-headed screws), and pre- and postradiographic (lumbar lordosis, pelvic incidence, pelvic tilt, major Cobb angle, lumbosacral fractional curve, C7 coronal vertical axis [CVA], T1 pelvic angle, C7 sagittal vertical axis) parameters was collected. All rods across the lumbosacral junction were cobalt-chrome. All iliac and S2AI screws were closed-headed tulips. Both univariate and multivariate analyses were performed to determine risk factors for PFF. RESULTS: Of 253 patients (mean age 58.9 years, mean TIL 13.6, 3CO 15.8%, L5-S1 interbody 74.7%, mean pelvic screw diameter/length 8.6/87 mm), the 2-year failure rate was 4.3% (n = 11). The mechanisms of failure included broken rods across the lumbosacral junction (n = 4), pseudarthrosis across the lumbosacral junction requiring revision to pelvic screws (n = 3), broken pelvic screw (n = 1), loose pelvic screw (n = 1), sacral/iliac fracture (n = 1), and painful/prominent pelvic screw (n = 1). A higher number of rods crossing the lumbopelvic junction (mean 3.8 no failure vs 2.9 failure, p = 0.009) and accessory rod LIV to S2/ilium (no failure 54.2% vs failure 18.2%, p = 0.003) were protective for failure. Multivariate analysis demonstrated that accessory rod LIV to S2/ilium versus S1 (OR 0.2, p = 0.004) and number of rods crossing the lumbar to pelvis (OR 0.15, p = 0.002) were protective, while worse postoperative CVA (OR 1.5, p = 0.028) was an independent risk factor for failure. CONCLUSIONS: The 2-year PFF rate was low relative to what is reported in the literature, despite patients undergoing long fusion constructs for ASD. The number of rods crossing the lumbopelvic junction and accessory rod LIV to S2/ilium relative to S1 alone likely increase construct stiffness. Residual postoperative coronal malalignment should be avoided to reduce PFF.


Assuntos
Lordose , Pseudoartrose , Fusão Vertebral , Humanos , Adulto , Pessoa de Meia-Idade , Adolescente , Pseudoartrose/diagnóstico por imagem , Pseudoartrose/epidemiologia , Pseudoartrose/etiologia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Pelve/cirurgia , Lordose/diagnóstico por imagem , Lordose/cirurgia , Lordose/etiologia , Parafusos Ósseos , Sacro/diagnóstico por imagem , Sacro/cirurgia , Ílio/diagnóstico por imagem , Ílio/cirurgia , Fusão Vertebral/efeitos adversos
15.
Cureus ; 15(12): e50363, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38213375

RESUMO

The aging population is witnessing a steady increase in the incidence of displaced proximal humerus fractures, particularly among elderly patients. Such fractures pose a significant challenge to orthopedic surgeons, given the complex interplay of factors involved, including fracture displacement, comminution, compromised bone quality, and the presence of concurrent medical comorbidities. While open reduction internal fixation (ORIF) remains a viable treatment option for these fractures, it is a technically demanding procedure associated with a high incidence of complications. Recently, reverse total shoulder arthroplasty (RTSA) with tuberosity repair has gained popularity as a successful approach for addressing such fractures. The present case report details a unique and complex case of a chronic four-part proximal humerus fracture, complicated by avascular necrosis of the humeral head, fracture non-union, and hardware penetration. The patient was successfully treated through a reverse shoulder arthroplasty procedure, highlighting the effectiveness of this surgical approach in such challenging scenarios. The advantages of RTSA in this context include the potential to address avascular necrosis, non-union, and hardware complications, as seen in our patient. Additionally, the procedure can restore functional independence and improve the overall quality of life in these challenging cases.

16.
Arch Bone Jt Surg ; 10(10): 863-870, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36452422

RESUMO

Background: The purpose of this study is to compare the incidence of complications associated with tension band wiring (TBW) versus plate osteosynthesis (POS) in the treatment of olecranon fractures. Methods: We performed a retrospective cohort study of operatively treated adult olecranon fractures from an integrated healthcare system by multiple surgeons from January 2008 to December 2011. Patients were divided into two cohorts: fractures fixed using the tension band technique and fractures fixed using plate osteosynthesis. The study was limited to the Orthopedic Trauma Association classification of olecranon fracture type 21-B1, with subtypes 1-3. Outcome measures were loss of fracture fixation requiring revision, postoperative infection, stiffness requiring surgery, and symptomatic hardware removal (HWR). Univariate and multivariable logistic regressions were performed to test the associations between the type of internal fixation and outcomes. Results: A total of 321 olecranon fractures were included (median age: 61 years old, 57 % female); 153 participants were treated with TBW, and 168 patients with POS. There was one failure in the TBW group and two in the POS group (P=0.62). There were no significant differences in the infection rates (TBW 5%, POS 9%, P=0.20) and no reoperations for stiffness. The HWR occurred significantly more often in TBW (29%) than in POS (14%) (OR=0.39, P=0.001). The association between POS and decreased HWR remained highly significant (OR=0.40, P=0.003) after adjusting for clinical variables. Conclusion: In this large study comparing POS and TBW for 21-B1 olecranon fractures, no difference in fixation failure, infection, or postoperative stiffness was noted. A significantly greater risk of symptomatic hardware occurred in TBW. These findings may assist surgeons and patients in considering the risks and benefits of TBW and POS as treatment options for displaced olecranon fractures.

17.
Artigo em Espanhol | LILACS, UY-BNMED, BNUY | ID: biblio-1403140

RESUMO

El método de Ilizarov, con sus diferentes variantes y mediante la utilización de su aparato, desarrollado en la década del 50, continúa vigente, sobre todo en el tratamiento de las complicaciones de fracturas, principalmente aquellas vinculadas a la infección y a las dificultades de la consolidación. Reportamos 2 pacientes adultos con diagnóstico de pseudoartrosis hipertrófica, rígida, con deformidad, sin infección activa y sin dismetría, tratados mediante el método de distracción y compresión realizado con el aparato de Ilizarov. En ambos casos se logró la alineación y consolidación del miembro con escasas complicaciones.


The Ilizarov method, with its different variants and using its apparatus, developed in the 1950s, is still valid, especially in the treatment of fracture complications, mainly those linked to infection and consolidation difficulties. We report 2 adult patients with a diagnosis of hypertrophic, rigid nonunion, with deformity, without active infection and without dysmetria, treated by the distraction and compression method performed with the Ilizarov device. In both cases, the alignment and consolidation of the limb was achieved with few complications.


O método de Ilizarov, com suas diferentes variantes e pelo uso de seu aparato, desenvolvido na década de 1950, ainda é válido, principalmente no tratamento de complicações de fraturas, principalmente aquelas ligadas à infecção e dificuldades de consolidação. Relatamos 2 pacientes adultos com diagnóstico de pseudoartrose hipertrófica, rígida, com deformidade, sem infecção ativa e sem dismetria, tratados pelo método de distração e compressão realizado com o dispositivo de Ilizarov. Em ambos os casos, o alinhamento e a consolidação do membro foram alcançados com poucas complicações.


Assuntos
Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Pseudoartrose/cirurgia , Fraturas da Tíbia/cirurgia , Técnica de Ilizarov , Período Pós-Operatório , Fraturas da Tíbia/complicações , Seguimentos , Resultado do Tratamento , Período Intraoperatório
18.
J Orthop Case Rep ; 12(4): 5-8, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36380991

RESUMO

Introduction: Modified tension band wiring (MTBW) using two cannulated cancellous screws which also achieve a horizontal figure of eight patterns of tension band is established as a superior fixation to using Kirschner wires for type 34-C1 fracture of the patella. We are describing a case where this method was used for failed MTBW using two Kirschner wires where an impending failure in the early post-operative period proceeded to complete bony union without any implant failure or functional deficit following a period of conservative management. Case Presentation: We are describing a 67-year-old man with type 34-C1 fracture of patella treated by MTBW using Kirschner wires and a stainless steel (SS) wire, with fixation failure after around 6 weeks, which was revised by MTBW using two vertically placed cannulated partially threaded cancellous screws and SS wire as a tension band. In the early post-operative period, a routine X-ray of the operated part showed fracture fragment separation with a slight sack in the tension band wire without any signs of implant failure. To our surprise, the fracture proceeded to complete bony union while continuing gradually increased active knee range of motion exercises. Conclusion: This case report presents how an impending failure proceeded to complete fracture healing because of dynamic compression of the fracture provided by the tension band construct.

19.
J Clin Med ; 11(16)2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-36013114

RESUMO

Failed internal fixations for trochanteric fractures have a strong negative impact owing to increased postoperative mortality and high medical costs. However, evidence on the prognostic value of postoperative radiographic findings for failed internal fixations is limited. We aimed to clarify the association between comprehensive immediate postoperative radiographic findings and failed internal fixation using relative and absolute risk measures. We followed the meta-analysis of observational studies in epidemiology guidelines and the Cochrane handbook. We searched specific databases in November 2021. The outcomes of interest were failed internal fixation and cut-out. We pooled the odds ratios and 95% confidence intervals using a random-effects model and calculated the number needed to harm for each outcome. Thirty-six studies involving 8938 patients were included. The certainty of evidence in the association between postoperative radiographic findings and failed internal fixation or cut-out was mainly low or very low except for the association between intramedullary malreduction on the anteromedial cortex and failed internal fixation. Moderate certainty of evidence supported that intramedullary malreduction on the anteromedial cortex was associated with failed internal fixation. Most postoperative radiographic findings on immediate postoperative radiographs for trochanteric fractures were uncertain as prognostic factors for failed internal fixations.

20.
BMC Musculoskelet Disord ; 23(1): 769, 2022 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-35962387

RESUMO

BACKGROUND: To investigate the predictive value of the Singh index for the risk of InterTAN intramedullary fixation failure in elderly patients with intertrochanteric fracture to guide clinical treatment. METHODS: A total of 360 patients were divided into the Singh (I ~ II) (n = 120), Singh (III ~ IV) (n = 120) and Singh (V ~ VI) (n = 120) groups. Visual analog scale (VAS) and Harris scores were recorded at 1, 6, 12, 18 and 24 months after the operation. The correlation between the Singh index and the T-score of the total hip and femoral neck was analyzed. Logistic regression was used to analyze the relationship between the Singh index and internal fixation failure; the types of internal fixation failure were also analyzed. RESULTS: The Harris scores of the Singh (I ~ II) group were lower than those of the Singh (III ~ IV) and Singh (V ~ VI) groups 12, 18 and 24 months after surgery (P < 0.05). The Singh index was significantly correlated with the T-score of the total hip and femoral neck (P = 0.00, r = 0.89; P = 0.00, r = 0.83). The Singh (I ~ II) group had the lowest internal fixation survival rate within 24 months (P = 0.01). The Singh index was an independent predictor of internal fixation failure (P < 0.05). Lag screw cutting-out was the main type of internal fixation failure in the three groups (P = 0.00). CONCLUSION: The Singh index is significantly correlated with the bone mineral density of the femoral neck and total hip. The Singh (I ~ II) group had lower Harris scores and a lower internal fixation survival rate than the other two groups. The Singh index is an independent predictor of internal fixation failure, especially lag screw cutting-out, after InterTAN fixation.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Idoso , Pinos Ortopédicos , Parafusos Ósseos , Fixação Interna de Fraturas/efeitos adversos , Fixação Intramedular de Fraturas/efeitos adversos , Fraturas do Quadril/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS