Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Anaesthesia ; 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39327940

RESUMO

BACKGROUND: Anaesthetists of all grades who work on a labour ward are likely to be involved in the insertion or management of an intrathecal catheter after inadvertent dural puncture at some point in their careers. Although the use of intrathecal catheters after inadvertent dural puncture in labour has increased in popularity over recent decades, robust evidence on best practice has been lacking. METHODS: The Obstetric Anaesthetists' Association set up an expert working party to review the literature. A modified Delphi approach was used to produce statements and recommendations on insertion and management of intrathecal catheters for labour and operative delivery following inadvertent dural puncture during attempted labour epidural insertion. Statements and recommendations were graded according to the US Preventive Services Task Force grading methodology. RESULTS: A total of 296 articles were identified in the initial literature search. Further screening identified 111 full text papers of relevance. A structured narrative review was produced which covered insertion of an intrathecal catheter; initial dosing; maintenance of labour analgesia; topping-up for operative delivery; safety features; complications; and recommended follow-up. The working party agreed on 17 statements and 26 recommendations. These were generally assigned a low or moderate level of certainty. The safety of mother and baby were a key priority in producing these guidelines. CONCLUSIONS: With careful management, intrathecal catheters can provide excellent labour analgesia and may also be topped-up to provide anaesthesia for caesarean or operative vaginal delivery. The use of intrathecal catheters, however, also carries the risk of significant drug errors which may result in high- or total-spinal anaesthesia, or even cardiorespiratory arrest. It is vital that all labour wards have clear guidelines on the use of these catheters, and that staff are educated as to their potential complications.

3.
J Anesth Analg Crit Care ; 3(1): 22, 2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37475027

RESUMO

BACKGROUND: Accidental dural puncture is a common complication of labour analgesia. It can trigger post-dural puncture headache, with associated morbidity and increased costs. Intrathecal catheter placement is a prophylactic procedure which can reduce incidence and severity of post-dural puncture headache. METHODS: We conducted a retrospective single-centred study to define incidence and risk factors of accidental dural puncture and post-dural puncture headache in an obstetric population. We also evaluated effectiveness of intrathecal catheter placement compared to epidural catheter replacement in reducing incidence of post-dural puncture headache. We then conducted a systematic review and meta-analysis which included all studies comparing intrathecal catheter placement to epidural catheter replacement in obstetric patients with accidental dural puncture assessing the outcome of reduced incidence of post-dural puncture headache as a dichotomous variable. RESULTS: Accidental dural puncture had an incidence of 0.25% (60 cases). Of these, 66% developed post-dural puncture headache. A total of 77% (47/60) of patients with accidental dural puncture were treated with an intrathecal catheter placement, while 23% (13/60) had an epidural catheter replacement. Incidence of post-dural puncture headache was lower in the intrathecal catheter group (spinal 26/47, 60.5% epidural 11/13, 84.6%), although not reaching statistical significance (RR 0.71, CI 95%: 0.51-1.00; p = 0.049). The meta-analysis revealed that intrathecal catheter placement significantly reduced incidence of post-dural puncture headache compared to epidural catheter replacement (pooled RR 0.81, 95% CI 0.72-0.91, p < 0.001). CONCLUSIONS: Intrathecal catheter placement is a promising measure to prevent post-dural puncture headache, especially if followed by a pain management protocol and a continuous saline infusion.

4.
J Med Case Rep ; 17(1): 239, 2023 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-37301817

RESUMO

BACKGROUND: Intrathecal baclofen therapy can substantially improve symptoms in most patients with severe spasticity due to traumatic spinal cord injury, multiple sclerosis, or cerebral paresis. To the best of our knowledge, decompression surgeries at the intrathecal catheter insertion site in patients with a preexisting intrathecal pump for drug delivery have not been reported. CASE PRESENTATION: We report the case of a 61-year-old Japanese man with lumbar spinal stenosis who underwent intrathecal baclofen therapy. We performed decompression for lumbar spinal stenosis at the intrathecal catheter insertion site during intrathecal baclofen therapy. The yellow ligament was removed by partial resection of the lamina under a microscope to avoid damage to the intrathecal catheter. The dura mater was distended. No obvious cerebrospinal fluid leakage was observed. Postoperatively, lumbar spinal stenosis symptoms improved, and spasticity remained well controlled with intrathecal baclofen therapy. CONCLUSIONS: This is the first reported case of lumbar spinal stenosis decompression at an intrathecal catheter insertion site during intrathecal baclofen therapy. Preoperative preparation is necessary, as the intrathecal catheter may be replaced during surgery. We performed surgery without removing or replacing the intrathecal catheter, taking care not to damage the spinal cord by migrating the intrathecal catheter.


Assuntos
Relaxantes Musculares Centrais , Estenose Espinal , Masculino , Humanos , Pessoa de Meia-Idade , Baclofeno/efeitos adversos , Estenose Espinal/complicações , Estenose Espinal/cirurgia , Injeções Espinhais , Espasticidade Muscular/etiologia , Espasticidade Muscular/induzido quimicamente , Descompressão/efeitos adversos , Catéteres/efeitos adversos
5.
BJA Educ ; 22(8): 295-297, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36097572
6.
Best Pract Res Clin Anaesthesiol ; 36(1): 3-15, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35659957

RESUMO

The ideal technique for labor analgesia would have a quick onset, predictable quality, and adjustable depth and duration. Moreover, it would be easy to perform and have minimal maternal and fetal side effects. A catheter-based neuraxial approach encompasses these desirable characteristics and includes the epidural, combined spinal epidural, dural puncture epidural, and intrathecal catheter techniques. In this review, we outline the unique technical considerations, analgesic characteristics, and side effect profiles for each technique that can ultimately impact the maternal-fetal dyad. The selection of neuraxial analgesia techniques should consider the patient and team's goals and expectations, the clinical context, and the institutional culture. Labor analgesic techniques that initiate with an intentional dural puncture component have a faster onset, greater bilateral and sacral spread, and lower rates of epidural catheter failure. Further elucidation of the mechanisms, benefits, and risks of each neuraxial initiation technique will continue to benefit patients and care providers.


Assuntos
Analgesia Epidural , Analgesia Obstétrica , Anestesia Epidural , Trabalho de Parto , Analgesia Epidural/métodos , Analgesia Obstétrica/métodos , Analgésicos , Feminino , Humanos , Gravidez
7.
Cureus ; 13(6): e15643, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34306853

RESUMO

Anesthetic implications for morbidly obese parturients have been well described; however, the literature has not yet clarified whether there are additional or unique concerns if the body mass index (BMI) rises farther above the so-called super morbid obesity level: BMI >50 kg/m2. There have only been a few case reports focusing on patients with BMI close to or above 100. Parturients with BMI significantly greater than 50 are uncommon, but they represent an increasing proportion among the morbidly obese. In this report, we present the use of continuous spinal anesthesia in consecutive cesarean deliveries for a patient with a BMI of 102 at her first delivery and 116 at her second. For both deliveries, an intrathecal catheter dosing incrementally provided effective anesthesia with a cumulative dose of hyperbaric bupivacaine 12 mg, fentanyl 15 mcg, and morphine 100 mcg given in 0.25-ml increments over 12 minutes, with 0.25-ml sterile saline flushes between doses. While dosing the catheter, the patient was gradually lowered to a 30° semi-recumbent position for surgery. This strategy minimized the risk of high spinal block or respiratory distress. She did not develop any postdural puncture headache (PDPH). This case report offers an extreme example and provides estimates towards adjusting staffing, equipment, location, timing, positioning, anesthetic technique, and dosing for cesarean deliveries in patients with very high BMI levels.

8.
J Neurosurg Case Lessons ; 2(3): CASE21285, 2021 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35854910

RESUMO

BACKGROUND: Deep brain stimulation (DBS) is a U.S. Food and Drug Administration-approved therapy for medically refractory Parkinson's disease, essential tremor, and other neurological conditions. The procedure requires prolonged immobility and can result in significant patient discomfort, potentially limiting patient selection. In addition, surgical requirements necessitate avoidance of medications that may alter or suppress the patient's arousal or baseline tremor during macrostimulation testing. OBSERVATIONS: In this study, the authors describe the use of continuous spinal anesthesia with local anesthetic to manage a patient with severe back pain who was intolerant of semisupine position during stereotactic computed tomography and stage 1 of DBS placement. LESSONS: Continuous spinal anesthesia is an effective strategy to manage patients with severe back pain undergoing DBS surgery for upper extremity motor symptoms.

9.
Int J Obstet Anesth ; 41: 71-82, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31522933

RESUMO

BACKGROUND: Our meta-analysis from 2013 showed that inserting a catheter intrathecally after an observed accidental dural puncture can reduce the need for epidural blood patch in labouring women requesting epidural analgesia. We updated our conventional meta-analysis and added a trial-sequential analysis (TSA). METHODS: A systematic literature search was conducted to identify studies that compared inserting the catheter intrathecally with an epidural catheter re-site or with no intervention. The extracted data were pooled and the risk ratio (RR) and 95% confidence interval (95%CI) for the incidence of post-dural puncture headache (PDPH) was calculated, using the random effects model. A contour-enhanced funnel plot was constructed. A TSA was performed and the cumulative Z score, monitoring and futility boundaries were constructed. RESULTS: Our search identified 13 studies, reporting on 1653 patients, with a low risk of bias. The RR for the incidence of PDPH was 0.82 (95%CI 0.71 to 0.95) and the RR for the need for epidural blood patch was 0.62 (95%CI 0.49 to 0.79); heterogeneity of both analyses was high. The TSA showed that the monitoring or futility boundaries were not crossed, indicating insufficient data to exclude a type I error of statistical analysis. Contour-enhanced funnel plots were symmetric, suggesting no publication bias. CONCLUSIONS: Conventional meta-analyses showed for the first time that intrathecal catheterisation can reduce the incidence of PDPH. However, TSA did not corroborate this finding. Despite increasing use in clinical practice there is no firm evidence on which to base a definite conclusion.


Assuntos
Analgesia Epidural/efeitos adversos , Analgesia Obstétrica/efeitos adversos , Cateterismo/métodos , Cefaleia Pós-Punção Dural/prevenção & controle , Punção Espinal , Feminino , Humanos , Cefaleia Pós-Punção Dural/etiologia , Gravidez
10.
J Clin Neurosci ; 68: 33-38, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31400999

RESUMO

Intrathecal baclofen infusion trial is a sophisticated tool for selecting patients for permanent intra thecal baclofen infusion therapy We report our clinical experience of fifteen patients with refractory spasticity who underwent a continuous ITB trial using a temporary intraspinal indwelling catheter prior to permanent pump implantation. Patients underwent placement of a temporary intrathecal catheter that was connected to an external pump. Multisource feedback was obtained from the various healthcare professionals involved (Staff Nurse, Specialist nurse, physiotherapist, Doctor, family members, patient) regarding progress of test over 48-72 h. Average Modified Ashworth score after the trial was less than 2. Some degree of dose related minor adverse events (AEs) occurred in 8 patients, with the most common being nausea, constipation, urinary retention and hypotension. 10 patients received pump implant. 5 patients did not receive a pump because of AEs or because the goals were not met. 1 patient had pump removed after 4 years because of infection.


Assuntos
Baclofeno/administração & dosagem , Relaxantes Musculares Centrais/administração & dosagem , Espasticidade Muscular/tratamento farmacológico , Seleção de Pacientes , Idoso , Baclofeno/efeitos adversos , Cateteres de Demora , Feminino , Humanos , Bombas de Infusão Implantáveis , Injeções Espinhais , Masculino , Pessoa de Meia-Idade , Relaxantes Musculares Centrais/efeitos adversos , Estudos Retrospectivos
11.
Neuromodulation ; 22(7): 839-842, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31157471

RESUMO

INTRODUCTION: Two patients previously implanted with intrathecal Baclofen (ITB) pumps for management of intractable spasticity due to multiple sclerosis (MS) were referred to our center for ongoing management of their spasticity. Initial evaluation of these patients revealed high levels of spasticity in the presence of ITB doses 10 times the average daily dose of our other MS patients. CLINICAL FACTS: High doses of ITB required frequent clinical visits and result in high drug and procedure costs. Both patients' daily doses were greater than 1000 mcg/day resulting in clinical visits every 1-2 months with drug and procedure costs ranging from 16 to 23 thousand dollars annually based on Medicare national average pricing for physician's office. Of the 59 MS patients receiving ITB therapy at our institution, the mean, median, and mode daily doses for ITB are 184, 115, and 159 mcg/day, respectively. The high ITB doses in these patients and poor spasticity control raised suspicion for pump/catheter malfunction and prompted immediate troubleshooting. FINDINGS: One patient's catheter was found to be disconnected from the pump and the other's catheter tip was outside the intrathecal space. In both cases, the patients were not receiving the therapy. After pump/catheter replacement, both patients received excellent clinical benefits from ITB at significantly lower daily doses. This reduction in dose resulted in decreased frequency of medication refills (twice annually) which resulted in decreased cost of care (12-19 thousand dollars savings annually per patient). DISCUSSION: These cases illustrate the need for early ITB pump troubleshooting to identify catheter problems, improve efficacy, and avoid unnecessary healthcare costs.


Assuntos
Baclofeno/administração & dosagem , Cateteres de Demora/normas , Custos de Cuidados de Saúde/normas , Esclerose Múltipla/tratamento farmacológico , Relaxantes Musculares Centrais/administração & dosagem , Espasticidade Muscular/tratamento farmacológico , Adulto , Idoso , Baclofeno/economia , Cateteres de Demora/efeitos adversos , Cateteres de Demora/economia , Feminino , Humanos , Bombas de Infusão Implantáveis/efeitos adversos , Bombas de Infusão Implantáveis/economia , Bombas de Infusão Implantáveis/normas , Injeções Espinhais/efeitos adversos , Injeções Espinhais/economia , Injeções Espinhais/normas , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/economia , Relaxantes Musculares Centrais/economia , Espasticidade Muscular/diagnóstico por imagem , Espasticidade Muscular/economia , Resultado do Tratamento
12.
Int J Obstet Anesth ; 36: 11-16, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30245259

RESUMO

BACKGROUND: There is no clear consensus about how best to prevent post-dural puncture headache (PDPH) following an accidental dural puncture in parturients. Our primary objective was to investigate whether the insertion of an intrathecal catheter following accidental dural puncture reduces the incidence of PDPH and therapeutic epidural blood patch. METHODS: Anaesthetic records from January 2009 to December 2015 were reviewed retrospectively and parturients who had an accidental dural puncture and/or PDPH were identified. Data from those with a recognised dural puncture in whom an intrathecal catheter was inserted at the time of accidental dural puncture (ITC group) were compared to those without an intrathecal catheter (non-ITC group), as were outcomes of patients with an intrathecal catheter for ≥24 hours compared to <24 hours. RESULTS: Of 94 recognised accidental dural punctures, 66 were in the ITC group (37 for ≥24 h) and 28 in the non-ITC group. In the ITC group, 22 (33.3%) required an epidural blood patch in comparison to 19 (67.9%) in the non-ITC group (P <0.01, 95% CI 12.5 to 52.0). In the ITC group, 62 (93.9%) developed PDPH in comparison to 28 (100%) in the non-ITC group (P=0.186, 95% CI -6.55 to 14.57). Intrathecal catheter insertion for ≥24 h obviated the need for an epidural blood patch in 28 (75.7%) parturients, compared to 13 (59.1%) if <24 h (P=0.184, 95% CI -7.08 to 39.72). CONCLUSION: Inserting an intrathecal catheter after a recognised accidental dural puncture significantly reduced the need for an epidural blood patch.


Assuntos
Anestesia Epidural/instrumentação , Anestesia Obstétrica/instrumentação , Placa de Sangue Epidural/estatística & dados numéricos , Cefaleia Pós-Punção Dural/epidemiologia , Cefaleia Pós-Punção Dural/terapia , Punção Espinal/efeitos adversos , Adulto , Anestesia Epidural/métodos , Anestesia Obstétrica/métodos , Austrália , Dura-Máter , Feminino , Humanos , Gravidez , Estudos Retrospectivos
13.
In Vivo ; 32(3): 583-590, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29695564

RESUMO

BACKGROUND/AIM: The aim of this study was to develop a method for sequentially collecting cerebrospinal fluid (CSF) from an unanesthetized microminipig, which shares many physiological and anatomical similarities with humans, such as diurnality, and investigate the diurnal variation of melatonin concentration in the CSF. MATERIALS AND METHODS: A catheter was placed percutaneously into the subarachnoid space of an anesthetized animal, and the tip of the catheter was placed into the cisterna magna under X-ray. We then sequentially collected CSF at light-on and -off times from the unanesthetized animal for several weeks. After catheter placement, a period of one week or more was necessary to relieve the contamination of RBCs in the CSF. RESULTS: A higher melatonin level in the CSF was noted during lights-off time, and the level was higher than that in the serum. CONCLUSION: This model of sequential collection of CSF will contribute to research in brain functions.


Assuntos
Ritmo Circadiano , Melatonina/líquido cefalorraquidiano , Porco Miniatura/líquido cefalorraquidiano , Aminoácidos/sangue , Aminoácidos/líquido cefalorraquidiano , Animais , Biomarcadores , Temperatura Corporal , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Catéteres , Líquido Cefalorraquidiano/química , Líquido Cefalorraquidiano/citologia , Feminino , Locomoção , Melatonina/sangue , Suínos , Tomografia Computadorizada por Raios X
14.
J Palliat Med ; 21(5): 727-729, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29649397

RESUMO

Surgical-site infection, spinal cord abscess, and catheter tip granuloma are known but rare complications of intrathecal drug delivery systems (IDDS). To date, there are no published cases of brain abscess in a patient with an IDDS. In this study, we report a case of a cancer patient with an IDDS for management of cancer pain who developed a brain abscess with profound mental status changes and clinical management challenges.


Assuntos
Analgésicos Opioides/efeitos adversos , Analgésicos Opioides/uso terapêutico , Abscesso Encefálico/induzido quimicamente , Abscesso Encefálico/terapia , Dor do Câncer/tratamento farmacológico , Sistemas de Liberação de Medicamentos/normas , Injeções Espinhais/normas , Humanos , Guias de Prática Clínica como Assunto , Estudos Retrospectivos
16.
Pain Pract ; 18(7): 889-894, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29480977

RESUMO

Opioids are often used for analgesia via continuous intrathecal delivery by implantable devices. A higher concentration and daily dose of opioid have been postulated as risk factors for intrathecal granuloma formation. We present a 42-year-old female patient with chronic abdominal pain from refractory pancreatitis, with an intrathecal drug delivery device implanted 21 years prior, delivering continuous intrathecal morphine. After many years without concerning physical signs or complaints, with gradual increases in daily morphine dose, she presented with rapidly progressive neurologic deficits, including lower extremity, bladder, and bowel symptoms. These symptoms were determined to be secondary to mass effect and local inflammation related to an intrathecal catheter tip granuloma, detected on magnetic resonance imaging of the spine. The mass was urgently resected. On histopathologic examination, this granuloma was found to be unique, in that in addition to the expected inflammatory components, it appeared to contain precipitated nonpolarizable crystals. These were identified as precipitated morphine using liquid extraction surface analysis-tandem mass spectrometry (LESA-MS/MS) and matrix-assisted laser desorption ionization-Fourier transform ion cyclotron resonance-mass spectrometry imaging (MALDI-FTICR-MSI). In addition to the unique finding of precipitated morphine crystals, the long-term follow-up of both morphine concentration and daily dose increases provides insight into the formation of intrathecal granulomas.


Assuntos
Analgésicos Opioides/efeitos adversos , Granuloma/induzido quimicamente , Morfina/efeitos adversos , Doenças da Medula Espinal/induzido quimicamente , Adulto , Analgésicos Opioides/administração & dosagem , Feminino , Granuloma/diagnóstico , Humanos , Bombas de Infusão Implantáveis , Infusão Espinal/efeitos adversos , Estudos Longitudinais , Morfina/administração & dosagem , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Doenças da Medula Espinal/diagnóstico , Espectrometria de Massas em Tandem
17.
J Neurosurg Pediatr ; 21(4): 389-394, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29372855

RESUMO

Intrathecal baclofen has been suggested as an effective and safe treatment for intractable spasticity and dystonia. Techniques of lumbar and intraventricular catheter placement have been previously described. The purpose of this study was to describe a technique to implant catheters for intrathecal baclofen infusion through C1-2 puncture. Four of 5 consecutively treated patients underwent successful placement of catheters for intrathecal baclofen. There were no instances of infection, CSF leak, or catheter migration seen during a follow-up period of at least 6 months; furthermore, there were no occurrences of vertebral artery or spinal cord injury. All patients had an effective stabilization or reduction of their upper-extremity, lower-extremity, or trunk tone. There were no cases of worsening hypertonia. The authors' preliminary experience with C1-2 puncture for placement of the intrathecal baclofen catheter seems to indicate that this is a safe and efficacious technique. Lessons learned from the failed attempt at C1-2 puncture will be delineated.


Assuntos
Baclofeno/administração & dosagem , Paralisia Cerebral/tratamento farmacológico , Bombas de Infusão Implantáveis , Relaxantes Musculares Centrais/administração & dosagem , Adolescente , Criança , Pré-Escolar , Epilepsia/complicações , Feminino , Humanos , Masculino , Quadriplegia/complicações , Escoliose/complicações
18.
Surg Neurol Int ; 8: 297, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29285413

RESUMO

BACKGROUND: Shearing of an intrathecal catheter during implantation of a drug delivery system is an underreported complication that can be challenging to manage. CASE DESCRIPTION: A 53-year-old man with refractory cancer pain had an intrathecal pump system implanted. The procedure was complicated with catheter shear and retention in the intrathecal space. A second catheter was successfully placed but formation of a painful pseudomeningocele and ineffective pain relief complicated the outcome. A minimally invasive approach through a tubular retractor was employed to access the spinal canal via a laminotomy, the sheared catheter was removed and the dural defect repaired. Complete resolution of the pseudomeningocele and efficient pain control were observed at follow-up. CONCLUSION: Minimally invasive approach to the spine is demonstrated as a safe and effective alternative in this case of retained catheter induced cerebrospinal fluid (CSF) leak.

19.
Surg Neurol Int ; 8: 159, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28808608

RESUMO

BACKGROUND: Catheter-associated inflammatory masses (CIMs) are a rare but serious complication of intrathecal drug delivery devices. CIM formation is influenced by local medication concentration, which is determined in part by flow dynamics at the catheter tip. Underlying spinal pathologies, such as neoplasms, may alter flow at the catheter tip, thereby contributing to CIM formation. Moreover, they may also complicate the clinical and radiologic diagnosis of a CIM. CASE DESCRIPTION: A 36-year-old man with neurofibromatosis type 1 presented to our emergency department with complaints of increased back pain and leg weakness. To treat pain secondary to his multiple spinal masses, he had previously undergone placement of an implantable drug delivery system, which infused a compounded drug of fentanyl and bupivacaine. Imaging studies depicted numerous masses consistent with neurofibromatosis, including a compressive mass located circumferentially at the porous catheter terminus and proximal to the catheter tip. Surgical removal of this mass was performed; pathologic findings were consistent with a catheter tip granuloma. CONCLUSIONS: In the described case, CIM formation likely resulted from a combination of, 1) an unusually high fentanyl concentration, and, 2) altered infusate flow due to spinal neurofibromas. Consideration of underlying spinal pathologies, particularly mass lesions, is critical to the management of intrathecal drug delivery devices.

20.
Anesthesiol Clin ; 35(1): 157-167, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28131118

RESUMO

Headache after dural puncture is a common complication accompanying neuraxial anesthesia. The proposed cause is loss of cerebrospinal fluid through the puncture into the epidural space. Although obstetric patients are at risk for the development of this headache because of female gender and young age, there is a difference in the obstetric population. Women who deliver by cesarean delivery have a lower incidence of headache after dural puncture compared with those who deliver vaginally. Treatment of postdural puncture headache is an epidural blood patch. Departments should develop protocols for management of accidental dural puncture, including appropriate follow-up and indications for further management.


Assuntos
Placa de Sangue Epidural/métodos , Medicina Baseada em Evidências/métodos , Cefaleia Pós-Punção Dural/terapia , Feminino , Humanos , Cefaleia Pós-Punção Dural/fisiopatologia , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA