Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
1.
Polymers (Basel) ; 16(15)2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39125193

RESUMO

The study focuses on harnessing recycled materials to create sustainable and efficient composites, addressing both environmental issues related to waste management and industrial requirements for materials with improved vibration damping properties. The research involves the analysis of the physico-mechanical properties of the obtained composites and the evaluation of their performance in practical applications. Composite materials were tested in terms of their tensile strength and vibration damping capabilities, considering stress-strain diagrams, vibration amplitudes, frequency response functions (FRFs) and vibration modes. The research results have shown that by adding PVC and FA to the rubber-based matrix composition, the stiffness decreases and elasticity increases. The use of FA in the structure of composite materials causes an increase in the vibration damping possibilities due to the fact that it contributes to the chemical properties of the analyzed composite materials. Additionally, the use of PVC results in increased material elasticity, as evidenced by the higher damping factor compared to materials containing only rubber. Simultaneously, the addition of FA and PVC in specific proportions (60 phr) can lead to a decrease in stiffness and a greater increase in the damping factor. The incorporation of PVC and fly ash (FA) particles into rubber-based matrix composites reduces their stiffness and increases their elasticity. These effects are due to the fact that FA particles behave as extensions of chemical bonds during traction, which contributes to the increase in yield elongation. In addition, the use of flexible PVC increases the elasticity of the material, which is evidenced by the increase in the damping factor.

2.
J Endod ; 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39089614

RESUMO

INTRODUCTION: This study aimed to compare a new multicolored rotary system with four heat-treated rotary instruments using the multimethod approach. METHODS: Three-hundred instruments of RCS Rainbow, Rotate, RaCe EVO, OneCurve, and ProTaper Ultimate systems were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy, and mechanical performance (cyclic fatigue, torsional resistance, bending and buckling resistance, and cutting ability). Unprepared surfaces after canal preparation of maxillary molars were evaluated using micro-computed tomography. Kruskal-Wallis and one-way analysis of variance post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments exhibited variations in active blade length, number of spirals, and cross-sectional designs. RCS Rainbow showed specific phase transformation temperatures, highest bending (400.5gf) and buckling (286gf) resistance values, and lowest mean angle of rotation (529°) (P < .05). OneCurve exhibited superior cutting ability (8.4 mm) and longer time to fracture (112s). RaCe EVO displayed the lowest time to fracture (51s), maximum torque (1.2 N.cm), buckling (174gf), and bending resistance (261gf) values (P < .05). ProTaper Ultimate showed the highest torque (1.6 N.cm) and angle of rotation (611°) (P < .05), while its bending load (262gf) was comparable to RaCe EVO (P > .05). Rotate instrument showed intermediate values in the mechanical tests. No difference was observed regarding the unprepared canal surfaces (P > .05) CONCLUSIONS: RCS Rainbow demonstrates a trade-off between flexibility and other mechanical properties. Its dimensions exceeded those of other instruments, affording it higher torque resistance, yet concurrently reducing its flexibility, angle of rotation, and cutting ability. OneCurve stands out as a well-balanced choice by integrating geometric design and mechanical performance.

3.
Asian Spine J ; 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39164024

RESUMO

Study Design: Biomechanical study. Purpose: To investigate the mechanical characteristics of bone models created from medical images. Overview of Literature: Recent advancements in three-dimensional (3D) printing technology have affected its application in surgery. However, a notable gap exists in the analyses of how patient's dimorphism and variations in vertebral body anatomy influence the maximum insertional torque (MIT) and pullout strength (POS) of pedicle screws (PS) in osteoporotic vertebral bone models derived from medical images. Methods: Male and female patients with computed tomography data were selected. Dimensions of the first thoracic (T1), fourth lumbar (L4), and fifth lumbar (L5) vertebrae were measured, and bone models consisting of the cancellous and cortical bones made from polyurethane foam were created. PS with diameters of 4.5 mm, 5.5 mm, and 6.5 mm were used. T1 PS were 25 mm long, and L4 and L5 PS were 40 mm long. The bone models were secured with cement, and the MIT was measured using a calibrated torque wrench. After MIT testing, the PS head was attached to the machine's crosshead. POS was then calculated at a crosshead speed of 5 mm/min until failure. Results: The L4 and L5 were notably larger in female bone models, whereas the T1 vertebra was larger in male bone models. Consequently, the MIT and POS for L4 and L5 were higher in female bone models across all PS diameters than in male bone models. Conversely, the MIT for T1 was higher in male bone models across all PS; however, no significant differences were observed in the POS values for T1 between sexes. Conclusions: The mechanical properties of the proposed bone models can vary based on the vertebral structure and size. For accurate 3D surgical and mechanical simulations in the creation of custom-made medical devices, bone models must be constructed from patientspecific medical images.

4.
Polymers (Basel) ; 16(14)2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39065406

RESUMO

Resin composites have become the preferred choice for chairside provisional dental restorations. However, these materials may undergo discoloration, changes in surface roughness, and mechanical properties with aging in the oral cavity, compromising the aesthetics, functionality, and success of dental restorations. To investigate the color and mechanical stability of chairside provisional composite resins, this study evaluated the optical, surface, and mechanical properties of four temporary restoration resin materials before and after aging, stimulated by thermal cycling in double-distilled water. Measurements, including CIE LAB color analysis, three-point bending test, nanoindentation, scanning electron microscopy (SEM), and atomic force microscopy (AFM), were conducted (n = 15). Results showed significant differences among the materials in terms of optical, surface, and mechanical properties. Revotek LC (urethane dimethacrylate) demonstrated excellent color stability (ΔE00 = 0.53-Black/0.32-White), while Artificial Teeth Resin (polymethyl methacrylate) exhibited increased mechanical strength with aging (p < 0.05, FS = 68.40 MPa-non aging/87.21 MPa-aging). Structur 2 SC (Bis-acrylic) and Luxatemp automix plus (methyl methacrylate bis-acrylate) demonstrated moderate stability in optical and mechanical properties (Structur 2 SC: ΔE00 = 1.97-Black/1.38-White FS = 63.20 MPa-non aging/50.07 MPa-aging) (Luxatemp automix plus: ΔE00 = 2.49-Black/1.77-White FS = 87.72 MPa-non aging/83.93 MPa-aging). These results provide important practical guidance for clinical practitioners, as well as significant theoretical and experimental bases for the selection of restorative composite resins.

5.
Ann Anat ; 256: 152314, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39053668

RESUMO

This study aimed to evaluate the potential effects of Bisphenol F and S exposure on the skeletal structures of Sprague-Dawley rats. Given the increasing concern about the potential endocrine-disrupting effects of Bisphenol analogs on bone health, this research sought to elucidate their impact in conjunction with Melatonin. Using 80 male Sprague Dawley rats, bones were subjected to a 3-point bending test to assess mechanical properties, and histopathological evaluation was conducted after fixation and decalcification. Statistical analysis was performed using SPSS. The results of the mechanical tests revealed significant differences in deformation and elastic modulus values between groups treated with Bisphenol F+Melatonin and Bisphenol S+Melatonin compared to the control groups. However, the histological images showed no significant differences between the groups. In the discussion, it was noted that the injection of Bisphenol F and Melatonin together increased bone hardness, suggesting that Bisphenol F and Bisphenol S may mitigate the negative effects of melatonin on bone. We attributed the absence of histological differences to the male gender of the studied rats and previous exposure considerations. This study shows that Melatonin can reduce Bisphenol F and Bisphenol S' rapid adjustment effects and increase bone elasticity. The side effects of Bisphenol F and S, as well as the prophylactic effects of Melatonin, can be observed and improved by carefully adjusting the duration, dose, and gender selection.

6.
ACS Appl Mater Interfaces ; 16(26): 34057-34068, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38910292

RESUMO

The current longevity of dental resins intraorally is limited by susceptibility to acidic attacks from bacterial metabolic byproducts and vulnerability to enzymatic or hydrolytic degradation. Here, we demonstrate synthesizing an ionic liquid-based antibiofilm silane effective against Streptococcus mutans, a major caries pathogen. Furthermore, we incorporate this silane into dental resins, creating antibiofilm- and degradation-resistant materials applicable across resin types. FTIR, UV-vis, and NMR spectroscopy confirmed the synthesis of the expected ionic liquid-based silane. The characterization of SiO2 after the silanization indicated the presence of the silane and how it interacted with the oxide. All groups achieved a degree of conversion similar to that found for commercial resin composites immediately and after two months of storage in water. The minimum of 2.5 wt % of silane led to lower softening in solvent than the control group (GCTRL) (p < 0.05). While the flexural strength indicated a lower value from 1 wt % of silane compared to GCTRL (p < 0.05), the ultimate tensile strength did not indicate differences among groups (p > 0.05). There was no difference within groups between the immediate and long-term tests of flexural strength (p > 0.05) or ultimate tensile strength (p > 0.05). The addition of at least 5 wt % of silane reduced the viability of S. mutans compared to GCTRL (p < 0.05). The fluorescence microscopy analysis suggested that the higher the silane concentration, the higher the amount of bacteria with membrane defects. There was no difference among groups in the cytotoxicity test (p > 0.05). Therefore, the developed dental resins displayed biocompatibility, proper degree of conversion, improved resistance against softening in solvent, and stability after 6 months of storage in water. This material could be further developed to produce polymeric antimicrobial layers for different surfaces, supporting various potential avenues in developing novel biomaterials with enhanced therapeutic characteristics using ionic liquid-based materials.


Assuntos
Líquidos Iônicos , Nanopartículas , Silanos , Dióxido de Silício , Streptococcus mutans , Silanos/química , Silanos/farmacologia , Streptococcus mutans/efeitos dos fármacos , Dióxido de Silício/química , Dióxido de Silício/farmacologia , Líquidos Iônicos/química , Líquidos Iônicos/farmacologia , Nanopartículas/química , Antibacterianos/farmacologia , Antibacterianos/química , Animais , Resinas Compostas/química , Resinas Compostas/farmacologia , Camundongos , Biofilmes/efeitos dos fármacos , Resistência à Tração
7.
Dent Mater ; 40(9): 1477-1486, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38944559

RESUMO

OBJECTIVE: To assess the influence of calcination process on the properties of minimally processed recycled 3Y-TZP, and to compare it with its commercial counterpart. METHODS: Non-milled 3Y-TZP waste was collected, fragmented and ball-milled to a granulometric < 5 µm. Half of the recycled powder was calcined at 900 °C. Recycled 3Y-TZP disks were uniaxially pressed and sintered to create two recycled groups: 1) Calcined and 2) Non-calcined to be compared with a commercial CAD/CAM milled 3Y-TZP. The microstructure of experimental groups was assessed through density (n = 6), scanning electron microscopy (n = 3) and energy-dispersive X-ray spectroscopy (n = 3); and the crystalline content was evaluated through X-ray diffraction (XRD) (n = 3). Optical and mechanical properties were investigated through reflectance tests (n = 10), and Vickers hardness, fracture toughness (n = 5), and biaxial flexural strength tests (n = 16), respectively. Fractographic analysis was performed to identify fracture origin and crack propagation. Statistical analyses were performed through ANOVA followed by Tukey´s test, and by Weibull statistics. RESULTS: Particle size distribution of recycled powder revealed an average diameter of ∼1.60 µm. The relative density of all experimental groups was > 98.15 % and XRD analysis exhibited a predominance of tetragonal-phase in both recycled groups, which were similar to the crystallographic pattern of the control group. Cross-section micrographs presented flaws on the non-calcined group, and a more homogeneous microstructure for the calcined and commercial groups. Commercial samples showed lower contrast-ratio and higher translucency-parameter than the recycled groups, where non-calcined presented higher translucency-parameter and lower contrast-ratio than its calcined counterpart. The commercial group presented higher fracture toughness and characteristic strength than the recycled groups. Moreover, the calcined group exhibited higher hardness, characteristic strength, and probability of survival at higher loads than the non-calcined group. Fractographic analysis depicted the presence of microstructural flaws in the non-calcined group, which may have acted as stress-raisers and led to failures at lower flexural strengths values. SIGNIFICANCE: The calcination process improved the microstructure, optical, and mechanical properties of the recycled 3Y-TZP.


Assuntos
Resistência à Flexão , Teste de Materiais , Microscopia Eletrônica de Varredura , Pós , Reciclagem , Difração de Raios X , Zircônio , Zircônio/química , Ítrio/química , Dureza , Propriedades de Superfície , Espectrometria por Raios X , Desenho Assistido por Computador , Materiais Dentários/química
8.
Dent Traumatol ; 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38794914

RESUMO

BACKGROUND/AIM: 3D printing processes can be used to manufacture custom-made mouthguards for sports activities. Few studies have compared the impact performance of industrial-created mouthguards with that of custom-made mouthguards manufactured by thermoforming or 3D printing. The objective of this in vitro study was to compare the shock absorption capacities of custom-made mouthguards manufactured by 3D printing with industrial mouthguards and thermoformed ethylene vinyl acetate (EVA) mouthguards. MATERIALS AND METHODS: For each type of mouthguard, eight samples were produced. 3D-printed mouthguards were manufactured using digital light processing technology. Each mouthguard was subjected to an impact performance test defined by the standard AFNOR XP S72-427, which evaluate maximum deceleration and force transmitted during impact. The thickness of each mouthguard before and after a series of five impacts was measured at the impacted inter-incisal area. RESULTS: The mean maximum decelerations during impact ranged from 129 to 189 g for industrial mouthguards, 287 to 425 g for thermoformed EVA mouthguards, and 277 to 302 g for 3D-printed mouthguards. The mean reduction in mouthguard thickness at the impact zone after five tests was 1.2 mm for industrial mouthguards, 0.6 mm for 3D-printed mouthguards, and 2.2 mm for thermoformed EVA mouthguards. CONCLUSIONS: Custom-made 3D printed mouthguards showed slightly better shock absorption ability than thermoformed mouthguards with respect to the indicator proposed in XP S72-427. They seemed to combine the practical advantages of thermoformed mouthguards in sports with better shock absorption capacity and lower cost. Furthermore, they had the least thickness variation during the test, and their shock absorption capacity was the least affected by repeated mechanical tests. Other types of 3D-printing resin materials that will become available must continue to be tested for shock absorption to provide the best protection to users at low cost.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38780791

RESUMO

PURPOSE: We aim to compare interfragmentary compression with the position osteosynthesis in the fixation of different femoral neck fractures (FN) in synthetic bones subjected to vertical load. METHODS: Forty-two synthetic femurs were subjected to neck fractures and separated into 3 groups according to the Pauwels classification: Pauwels I had 6 units (PI); Pauwels II, 24 units, with and without comminution (PII); and Pauwels III, 12 units, with and without comminution (PIII). After, they were fixed with 2 different ways: three 7, 0 mm cannulated lag screws (CSs) versus three 6, 5 mm solid fully threaded screws (SSs). Screws positioning was oriented by the Pauwels classification: inverted triangle or crossed screws. All specimens were submitted to vertical loading until failure. RESULTS: The average force was 79.4 ± 22.6 Kgf. The greatest one was recorded in model 1 (135.6 Kgf), and the lowest in model 41 (39.6 Kgf). CSs and SSs had similar resistance until failure (p = 0.2). PI showed heightened resistance and PIII showed a worse response (p < 0,01). CSs had better performance in PIII (p = 0.048). Comminution and screws orientation caused no difference on peak force (p = 0.918 and p = 0.340, respectively). CONCLUSIONS: In synthetic bones, the resistance of a femoral neck fracture osteosynthesis using a 7, 0 mm cannulated lag screw or 6, 5 mm solid fully threaded screw are similar. There was no loss of efficiency with comminution in the femoral neck. Osteosynthesis resistance decreased with the verticalization of the fracture line and, in the more vertical ones, interfragmentary compression with CSs was more resistant than positional osteosynthesis with SSs.

10.
Traffic Inj Prev ; 25(4): 640-648, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38578292

RESUMO

OBJECTIVE: Occupant impact safety is critical for train development. This paper proposes a systematic procedure for developing validated numerical occupant crash scenarios for high-speed trains by integrating experimental, computational, and inverse methods. METHODS: As the train interior is the most potentially injury-causing factor, the material properties were acquired by mechanical tests, and constitutive models were calibrated using inverse methods. The validity of the seat material constitutive model was further verified via drop tower tests. Finite element (FE) and multibody (MB) models of train occupant-seat interactions in frontal impact were established in LS-DYNA and MADYMO software, respectively, using the experimentally acquired materials/mechanical characteristics. Three dummy sled crash tests with different folding table and backrest configurations were conducted to validate the numerical occupant-seat models and to further assess occupant injury in train collisions. The occupant impact responses between dummy tests and simulations were quantitatively compared using a correlation and analysis (CORA) objective rating method. RESULTS: Results indicated that the experimentally calibrated numerical seat-occupant models could effectively reproduce the occupant responses in bullet train collisions (CORA scores >80%). Compared with the train seat-occupant MB model, the FE model could simulate the head acceleration with slightly more acceptable fidelity, however, the FE model CORA scores were slightly less than for the MB models. The maximum head acceleration was 30 g but the maximum HIC score was 17.4. When opening the folding table, the occupant's chest injury was not obvious, but the neck-table contact and "chokehold" may potentially be severe and require further assessment. CONCLUSIONS: This study demonstrates the value of experimental data for occupant-seat model interactions in train collisions and provides practical help for train interior safety design and formulation of standards for rolling stock interior passive safety.


Assuntos
Acidentes de Trânsito , Traumatismos Torácicos , Humanos , Pescoço , Aceleração , Postura Sentada , Fenômenos Biomecânicos
11.
Heliyon ; 10(5): e26796, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38444492

RESUMO

Regeneration of injured tendons and ligaments (T/L) is a worldwide need. In this study electrospun hierarchical scaffolds made of a poly-L (lactic) acid/collagen blend were developed reproducing all the multiscale levels of aggregation of these tissues. Scanning electron microscopy, microCT and tensile mechanical tests were carried out, including a multiscale digital volume correlation analysis to measure the full-field strain distribution of electrospun structures. The principal strains (εp1 and εp3) described the pattern of strains caused by the nanofibers rearrangement, while the deviatoric strains (εD) revealed the related internal sliding of nanofibers and bundles. The results of this study confirmed the biomimicry of such electrospun hierarchical scaffolds, paving the way to further tissue engineering and clinical applications.

12.
Molecules ; 29(6)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38542842

RESUMO

This study concentrates on assessing the insecticidal attributes of the γ-Al2O3 nanoparticles derived from the remnants of Mentha pulegium, which include essential oil, ethanolic extract, and plant waste. The synthesis of the γ-Al2O3 nanoparticles was executed using a direct sol-gel procedure, affirming the crystal structure according to extensive physicochemical analyses such as UV-Vis, XRD, FTIR, and SEM. Evaluation of the insecticidal activity in vitro was conducted against Xylosandrus crassiusculus, a pest that infests carob wood, utilizing strains from diverse forests in the Khenifra region, situated in the Moroccan Middle Atlas. The lethal doses 50 ranged from 40 mg/g to 68 mg/g, indicating moderate effectiveness compared to the commercial insecticide Permethrin. Optimization of the conditions for the efficiency of the γ-Al2O3 nanoparticles was determined using experimental plans, revealing that time, humidity, and temperature were influential factors in the lethal dose 50 of these nanomaterials. Moreover, this study encompasses the establishment of correlations using Principal Component Analysis (PCA) and Ascending Hierarchical Classification (AHC) among various geographic, biological, and physical data, amalgamating geographic altitude and γ-Al2O3 nanoparticle insecticide parameters, as well as the attributes of the mechanical tests conducted on the carob wood affected by insects. The correlations highlight the close connections between the effectiveness of the insecticide, mountain altitude, and the mechanical parameters that were examined. Ultimately, these nanoparticles demonstrate promising potential as alternative insecticides, thus opening up encouraging prospects for safeguarding against carob wood pests.


Assuntos
Besouros , Galactanos , Inseticidas , Mananas , Mentha pulegium , Nanopartículas , Gomas Vegetais , Gorgulhos , Animais , Inseticidas/farmacologia , Inseticidas/química , Mentha pulegium/química
13.
Data Brief ; 53: 110218, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38425877

RESUMO

Concrete is a prominent construction material globally, owing to its reputed attributes such as robustness, endurance, optimal functionality, and adaptability. Formulating concrete mixtures poses a formidable challenge, mainly when introducing novel materials and additives and evaluating diverse design resistances. Recent methodologies for projecting concrete performance in fundamental aspects, including compressive strength, flexural strength, tensile strength, and durability (encompassing homogeneity, porosity, and internal structure), exist. However, actual approaches need more diversity in the materials and properties considered in their analyses. This dataset outlines the outcomes of an extensive 10-year laboratory investigation into concrete materials involving mechanical tests and non-destructive assessments within a comprehensive dataset denoted as ConcreteXAI. This dataset encompasses evaluations of mechanical performances and non-destructive tests. ConcreteXAI integrates a spectrum of analyzed mixtures comprising twelve distinct concrete formulations incorporating diverse additives and aggregate types. The dataset encompasses 18,480 data points, establishing itself as a cutting-edge resource for concrete analysis. ConcreteXAI acknowledges the influence of artificial intelligence techniques in various science fields. Emphatically, deep learning emerges as a precise methodology for analyzing and constructing predictive models. ConcreteXAI is designed to seamlessly integrate with deep learning models, enabling direct application of these models to predict or estimate desired attributes. Consequently, this dataset offers a resourceful avenue for researchers to develop high-quality prediction models for both mechanical and non-destructive tests on concrete elements, employing advanced deep learning techniques.

14.
Int Endod J ; 57(5): 601-616, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376108

RESUMO

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Assuntos
Instrumentos Odontológicos , Titânio , Estudos Transversais , Desenho de Equipamento , Teste de Materiais , Estresse Mecânico , Titânio/química , Preparo de Canal Radicular , Metalurgia
15.
ACS Nano ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38334316

RESUMO

Erucamide is known to play a critical role in modifying polymer fiber surface chemistry and morphology. However, its effects on fiber crystallinity and mechanical properties remain to be understood. Here, synchrotron nanofocused X-ray Diffraction (nXRD) revealed a bimodal orientation of the constituent polymer chains aligned along the fiber axis and cross-section, respectively. Erucamide promoted crystallinity in the fiber, leading to larger and more numerous lamellae crystallites. The nXRD nanostructual characterization is complemented by single-fiber uniaxial tensile tests, which showed that erucamide significantly affected fiber mechanical properties, decreasing fiber tensile strength and stiffness but enhancing fiber toughness, fracture strain, and ductility. To correlate these single-fiber nXRD and mechanical test results, we propose that erucamide mediated slip at the interfaces between crystallites and amorphous domains during stress-induced single-fiber crystallization, also decreasing the stress arising from the shear displacement of microfibrils and deformation of the macromolecular network. Linking the single-fiber crystal structure with the single-fiber mechanical properties, these findings provide the direct evidence on a single-fiber level for the role of erucamide in enhancing fiber "softness".

16.
Sensors (Basel) ; 24(2)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38257632

RESUMO

Shore hardness (SH) is a cost-effective and easy-to-use method to assess soft tissue biomechanics. Its use for the plantar soft tissue could enhance the clinical management of conditions such as diabetic foot complications, but its validity and reliability remain unclear. Twenty healthy adults were recruited for this study. Validity and reliability were assessed across six different plantar sites. The validity was assessed against shear wave (SW) elastography (the gold standard). SH was measured by two examiners to assess inter-rater reliability. Testing was repeated following a test/retest study design to assess intra-rater reliability. SH was significantly correlated with SW speed measured in the skin or in the microchamber layer of the first metatarsal head (MetHead), third MetHead and rearfoot. Intraclass correlation coefficients and Bland-Altman plots of limits of agreement indicated satisfactory levels of reliability for these sites. No significant correlation between SH and SW elastography was found for the hallux, 5th MetHead or midfoot. Reliability for these sites was also compromised. SH is a valid and reliable measurement for plantar soft tissue biomechanics in the first MetHead, the third MetHead and the rearfoot. Our results do not support the use of SH for the hallux, 5th MetHead or midfoot.


Assuntos
Ossos do Metatarso , Adulto , Humanos , Fenômenos Biomecânicos , Dureza , Reprodutibilidade dos Testes , Pé/diagnóstico por imagem
18.
Biomedicines ; 11(12)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38137506

RESUMO

We evaluated and compared the biomechanical properties of Leukocyte-and Platelet Rich Fibrin L-PRF clots and membranes derived from smoker and nonsmoker donors. Twenty venous-blood donors (aged 18 to 50 years) were included after signing informed consent forms. L-PRF clots were analyzed and then compressed to obtain L-PRF membranes. L-PRF clot and membrane samples were tested in quasi-static uniaxial tension and the stress-stretch response was registered and characterized. Furthermore, scanning electron microscope representative images were taken to see the fibrin structure from both groups. The analysis of stress-stretch curves allowed us to evaluate the statistical significance in differences between smoker and nonsmoker groups. L-PRF membranes showed a stiffer response and higher tensile strength when compared to L-PRF clots. However, no statistically significant differences were found between samples from smokers and nonsmokers. With the limitations of our in vitro study, we can suggest that the tensile properties of L-PRF clots and membranes from the blood of smokers and nonsmokers are similar. More studies are necessary to fully characterize the effect of smoking on the biomechanical behavior of this platelet concentrate, to further encourage its use as an alternative to promote wound healing in smokers.

19.
J Mech Behav Biomed Mater ; 148: 106219, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37951146

RESUMO

In this study, a three-component biofilm for rapid wound dressing consisting of polyvinyl alcohol (PVA)/tannic acid (TA)/with CuO/SiO2 with different percentages (0, 5, 10, and 15 wt% NPs) is evaluated. In addition to controlling bleeding and absorption of blood and wound secretions, it protects the damaged tissue from the attack of microbes. It protects against viruses and thus reduces the treatment time. Analysis of biofilms morphology is performed by Field emission scanning electron microscopy (FE-SEM), phases in biofilms were analyzed by X-ray diffraction (XRD) analysis, chemical bonds, and functional groups are analyzed by Fourier transform infrared (FTIR) spectroscopy, and mechanical tests are performed to evaluate the strength of the samples. The thermogravimetric analysis (TGA) is applied to estimate the thermal stability of the biopolymer films with various percentages of CuO/SiO2 nanoparticles. Also, antibacterial test, bioactivity of the biofilms, the percentage of swelling ratio, and porosity of the samples were examined by immersing the samples in simulated body fluid (SBF) and Phosphate-buffered saline (PBS) for 14 days in vitro. The composite makeup of the TA/PVA sample, comprising 15 wt % CuO/SiO2 and containing 15 wt% of nanoparticles, exhibited superior heat resistance compared to other samples by an increase of 50 °C. This improvement can be attributed to the nanoparticles reaching their saturation point. The swelling ratio was assessed in both SBF and PBS, and in both instances, the sample increased by up to 10 wt% before decreasing, indicating the saturation of the nanoparticles.


Assuntos
Materiais Biocompatíveis , Álcool de Polivinil , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/química , Álcool de Polivinil/farmacologia , Álcool de Polivinil/química , Dióxido de Silício/farmacologia , Polímeros , Antibacterianos/farmacologia , Antibacterianos/química , Espectroscopia de Infravermelho com Transformada de Fourier
20.
Heliyon ; 9(9): e20194, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37809432

RESUMO

The global production of polymer materials has exploded in the last few decades. Their mechanical properties, erosion and corrosion resistance, good performance as insulation materials, and their ease and flexibility of manufacturing have made polymers one of the most widely used materials in the industry and in daily life. Several institutions and governments are beginning to raise serious environmental and ecological concerns with international impact soon, due to the increasing level of polymer production, which does not seem to be slowing down. It is necessary for the scientific community to make efforts in the development and evaluation of new methodologies to enable the inclusion of these types of materials in the circular economy of various production sectors. This is important in order to reduce the ecological impact caused by the current global production level of polymers. One of the most used methods for the recovery of polymeric materials is energy valorization through thermochemical processes. An example of this is thermal gasification using fuels composed of biomass and a mixture of polymeric waste from electrical and electronic equipment (WEEE). Through this thermochemical process, high-energy value synthesis gas, with a high concentration of hydrogen, is obtained on one hand, while waste products in the form of chars, ashes and slag are generated on the other hand. This manuscript presents a detailed study methodology that begins with chemical analysis of the raw material and includes subsequent analysis of mechanical results for the revaluation of these residual inert by-products, using them as partial substitutes in cement clinker to produce building mortars. This described methodology influences directly in the LCC (Life Cycle Costing) of final designed products in plastic and extend material life cycle Plastic materials are here to stay, so the study and optimization of polymer waste recovery processes are vital in achieving the Sustainable Development Goals (SDGs) set by the European Union in terms of efficiency and sustainability. It is also the only possible way to create an environmentally sustainable future world for future generations. After applying the described methodology, the mechanical test results show that the modified mortars exhibit established behaviour during the hardening time and similar strength growth compared to commercial mortars. The maximum mechanical strengths achieved, including compressive and flexural strength, make modified mortars a viable choice for several applications in the civil engineering sector.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA