Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 14716, 2024 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961078

RESUMO

Microalgae are considered to be more useful and effective to use in biomass production than other photosynthesis organisms. However, microalgae need to be altered to acquire more desirable traits for the relevant purpose. Although neutron radiation is known to induce DNA mutations, there have been few studies on its application to microalgae, and the optimal relationship between irradiation intensity and mutation occurrence has not been established. In this study, using the unicellular red alga Cyanidioschyzon merolae as a model, we analyzed the relationship between the absorbed dose of two types of neutrons, high-energy (above 1 MeV) and thermal (around 25 meV) neutrons, and mutation occurrence while monitoring mutations in URA5.3 gene encoding UMP synthase. As a result, the highest mutational occurrence was observed when the cells were irradiated with 20 Gy of high-energy neutrons and 13 Gy of thermal neutrons. Using these optimal neutron irradiation conditions, we next attempted to improve the lipid accumulation of Euglena gracilis, which is a candidate strain for biofuel feedstock production. As a result, we obtained several strains with a maximum 1.3-fold increase in lipid accumulation compared with the wild-type. These results indicate that microalgae breeding by neutron irradiation is effective.


Assuntos
Euglena gracilis , Metabolismo dos Lipídeos , Euglena gracilis/genética , Euglena gracilis/efeitos da radiação , Euglena gracilis/metabolismo , Metabolismo dos Lipídeos/efeitos da radiação , Metabolismo dos Lipídeos/genética , Microalgas/genética , Microalgas/efeitos da radiação , Microalgas/metabolismo , Nêutrons , Mutação , Biomassa , Lipídeos , Biocombustíveis
2.
J Radiat Res ; 64(4): 661-667, 2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37295954

RESUMO

This study aimed to quantify the relative biological effectiveness (RBE) for epithermal neutron beam contaminated with fast neutrons in the accelerator-based boron neutron capture therapy (BNCT) system coupled to a solid-state lithium target. The experiments were performed in National Cancer Center Hospital (NCCH), Tokyo, Japan. Neutron irradiation with the system provided by Cancer Intelligence Care Systems (CICS), Inc. was performed. X-ray irradiation, which was assigned as the reference group, was also performed using a medical linear accelerator (LINAC) equipped in NCCH. The four cell lines (SAS, SCCVII, U87-MG and NB1RGB) were utilized to quantify RBE value for the neutron beam. Before both of those irradiations, all cells were collected and dispensed into vials. The doses of 10% cell surviving fraction (SF) (D10) were calculated by LQ model fitting. All cell experiments were conducted in triplicate at least. Because the system provides not only neutrons, but gamma-rays, the contribution from the gamma-rays to the survival fraction were subtracted in this study. D10 value of SAS, SCCVII, U87-MG and NB1RGB for the neutron beam was 4.26, 4.08, 5.81 and 2.72 Gy, respectively, while that acquired by the X-ray irradiation was 6.34, 7.21, 7.12 and 5.49 Gy, respectively. Comparison of both of the D10 values, RBE value of SAS, SCCVII, U87-MG and NB1RGB for the neutron beam was calculated as 1.7, 2.2, 1.3 and 2.5, respectively, and the average RBE value was 1.9. This study investigated RBE of the epithermal neutron beam contaminated with fast neutrons in the accelerator-based BNCT system coupled to a solid-state lithium target.


Assuntos
Terapia por Captura de Nêutron de Boro , Nêutrons Rápidos , Lítio , Nêutrons , Aceleradores de Partículas , Eficiência Biológica Relativa
4.
Front Oncol ; 13: 1284405, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38406173

RESUMO

More and more accelerator-based boron neutron capture therapy (AB-BNCT) facilities are under the construction or commissioning stage, and the neutron beam characteristic measurements at each facility will start soon. In addition to the in-field neutron beam properties, the leakage of neutron beam is also important, which is related to the side effects of the patient. In the Virtual Technical Meeting on Advances in Boron Neutron Capture Therapy held by International Atomic Energy Agency (IAEA) in July 2020, the issue of the out-of-field leakage in BNCT was addressed. Heron Neutron Medical Corporation has been working on the beam design for China Medical University Hsinchu Hospital AB-BNCT research center. To evaluate the out-of-field leakage, both beam profile analysis and whole-body dose calculation are performed. An Oak Ridge National Laboratory (ORNL) Medical Internal Radiation Dose (MIRD) mathematical phantom is used to calculate the whole-body dose. For the estimated irradiation time which is set to be the time required for 80% of tumor dose to reach 20 Gy-w, the relative biological effectiveness weighted dose of abdomen region is less than 40 mGy-w and the whole-body dose is 104 mSv. The beam profile calculational result shows that the neutron ambient dose equivalent at 15 cm from the field edge is 11 mSv/Gy-w and drops to 5 mSv/Gy-w at 26 cm from the field edge. The gamma ray ambient dose equivalent is less than 1 mSv/Gy-w starting from 10 cm from the field edge. Although the neutron out-of-field leakage of the beam design is higher than that of the initially proposed guideline by IAEA in 2020, the whole-body dose, however, is reasonably low. Both the whole-body dose evaluation and the beam profile analysis are useful in the beam design consideration. The whole-body dose calculation together with the beam profile analysis can also be helpful in reaching an acceptable recommendation for the out-of-field leakage for BNCT neutron beam, a job wished to be accomplished in the near future as proposed in the 2023 IAEA's report on Advances in Boron Neutron Capture Therapy.

5.
J Radiat Res ; 63(6): 817-827, 2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36253116

RESUMO

The primary motivation of this investigative study is trying to find an alternative treatment that can be used to slow down or treat glioblastoma due to the witnessed toxic side effects of the current drugs coupled with limited effectiveness in overall treatment. Consequently, a Chinese plant extract emodin proves to play a critical role in this investigative study since results from the Western blot and the other accompanying assays for anti-cancer effects indicate that it cannot work a lot to suppress cell migration and possible invasion, but rather emodin can be combined with radiation to give desired outcomes. Our result shows that the kind of radiation which acts well with emodin is neutron radiation rather than gamma radiation. Emodin significantly enhanced the radiosensitivity of LN18 and LN428 cells to γ-rays through MTT assay and cell counting. Accordingly, exposure to neutron radiation in the presence of emodin induced apoptotic cell death and autophagic cell death to a significantly higher extent, and suppressed cell migration and invasiveness more robustly. These effects are presumably due to the ability of emodin to amplify the effective dose from neutron radiation more efficiently. Thus, the study below is one such trial towards new interventional discovery and development in relation to glioblastoma treatment.


Assuntos
Emodina , Emodina/farmacologia , Emodina/uso terapêutico
6.
Sensors (Basel) ; 21(16)2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-34451067

RESUMO

High temperature reverse-bias (HTRB), High temperature gate-bias (HTGB) tests and electrical DC characterization were performed on planar-SiC power MOSFETs which survived to accelerated neutron irradiation tests carried out at ChipIr-ISIS (Didcot, UK) facility, with terrestrial neutrons. The neutron test campaigns on the SiC power MOSFETs (manufactered by ST) were conducted on the same wafer lot devices by STMicroelectronics and Airbus, with different neutron tester systems. HTGB and HTRB tests, which characterise gate-oxide integrity and junction robustness, show no difference between the non irradiated devices and those which survived to the neutron irradiation tests, with neutron fluence up to 2× 1011 (n/cm2). Electrical characterization performed pre and post-irradiation on different part number of power devices (Si, SiC MOSFETs and IGBTs) which survived to neutron irradiation tests does not show alteration of the data-sheet electrical parameters due to neutron interaction with the device.

7.
Biology (Basel) ; 10(3)2021 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-33652642

RESUMO

(1) Background:The quality of neutron beams for Boron Neutron Capture Therapy (BNCT) is currently defined by its physical characteristics in air. Recommendations exist to define whether a designed beam is useful for clinical treatment. This work presents a new way to evaluate neutron beams based on their clinical performance and on their safety, employing radiobiological quantities. (2) Methods: The case study is a neutron beam for deep-seated tumors from a 5 MeV proton beam coupled to a beryllium target. Physical Figures of Merit were used to design five beams; however, they did not allow a clear ranking of their quality in terms of therapeutic potential. The latter was then evaluated based on in-phantom dose distributions and on the calculation of the Uncomplicated Tumor Control Probability (UTCP). The safety of the beams was also evaluated calculating the in-patient out-of-beam dosimetry. (3) Results: All the beams ensured a UTCP comparable to the one of a clinical beam in phantom; the safety criterion allowed to choose the best candidate. When this was tested in the treatment planning of a real patient treated in Finland, the UTCP was still comparable to the one of the clinical beam. (4) Conclusions: Even when standard physical recommendations are not met, radiobiological and dosimetric criteria demonstrate to be a valid tool to select an effective and safe beam for patient treatment.

8.
Int J Mol Sci ; 21(11)2020 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-32466612

RESUMO

Radiotherapy using high linear energy transfer (LET) radiation results in effectively killing tumor cells while minimizing dose (biological effective) to normal tissues to block toxicity. It is well known that high LET radiation leads to lower cell survival per absorbed dose than low LET radiation. High-linear energy transfer (LET) neutron treatment induces autophagy in tumor cells, but its precise mechanisms in osteosarcoma are unknown. Here, we investigated this mechanism and the underlying signaling pathways. Autophagy induction was examined in gamma-ray-treated KHOS/NP and MG63 osteosarcoma cells along with exposure to high-LET neutrons. The relationship between radiosensitivity and autophagy was assessed by plotting the cell surviving fractions against autophagy levels. Neutron treatment increased autophagy rates in irradiated KHOS/NP and MG63 cells; neutrons with high-LETs showed more effective inhibition than those with lower LET gamma-rays. To determine whether the unfolded protein response and Akt-mTOR pathways triggered autophagy, phosphorylated eIF2α and JNK levels, and phospho-Akt, phosphor-mTOR, and phospho-p70S6 levels were, respectively, investigated. High-LET neutron exposure inhibited Akt phosphorylation and increased Beclin 1 expression during the unfolded protein response, thereby enhancing autophagy. The therapeutic efficacy of high-LET neutron radiation was also assessed in vivo using an orthotopic mouse model. Neutron-irradiated mice showed reduced tumor growth without toxicity relative to gamma-ray-treated mice. The effect of high-LET neutron exposure on the expression of signaling proteins LC3, p-elF2a, and p-JNK was investigated by immunohistochemistry. Tumors in high-LET-neutron radiation-treated mice showed higher apoptosis rates, and neutron exposure significantly elevated LC3 expression, and increased p-elF2a and p-JNK expression levels. Overall, these results demonstrate that autophagy is important in radiosensitivity, cell survival, and cellular resistance against high-LET neutron radiation. This correlation between cellular radiosensitivity and autophagy may be used to predict radiosensitivity in osteosarcoma.


Assuntos
Autofagia , Nêutrons/uso terapêutico , Osteossarcoma/radioterapia , Resposta a Proteínas não Dobradas , Animais , Linhagem Celular Tumoral , Células Cultivadas , Humanos , Transferência Linear de Energia , MAP Quinase Quinase 4/metabolismo , Camundongos , Proteínas Associadas aos Microtúbulos/metabolismo , Osteossarcoma/metabolismo , Proteínas Proto-Oncogênicas c-akt/metabolismo , Serina-Treonina Quinases TOR/metabolismo
9.
Phys Med ; 67: 9-19, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31610302

RESUMO

PURPOSE: Boron Neutron Capture Therapy (BNCT) is a treatment modality that uses an external neutron beam to selectively inactive boron10-loaded tumor cells. This work presents the development and innovative use of radiobiological probability models to adequately evaluate and compare the therapeutic potential and versatility of beams presenting different neutron energy spectra. M&M: Aforementioned characteristics, collectively refer to as the performance of a beam, were defined on the basis of radiobiological probability models for the first time in BNCT. A model of uncomplicated tumor control probability (UTCP) for HN cancer was introduced. This model considers a NTCP able to predict severe mucositis and a TCP for non-uniform doses derived herein. A systematic study comprising a simplified HN cancer model is presented as a practical application of the introduced radiobiological figures of merit (FOM) for assessing and comparing the performance of different clinical beams. Applications involving treated HN cancer patients were also analyzed. RESULTS: The maximum UTCP proved suitable and sensitive to assess the performance of a beam, revealing particularities of the studied sources that the physical FOMs do not highlight. The radiobiological FOMs evaluated in patients showed to be useful tools both for retrospective analysis of the BNCT treatments, and for prospective studies of beam optimization and feasibility. CONCLUSIONS: The presented developments and applications demonstrated that it is possible to assess and compare performances of completely different beams fairly and adequately by assessing the radiobiological FOM UTCP. Thus, this figure would be a practical and essential aid to guide treatment decisions.


Assuntos
Terapia por Captura de Nêutron de Boro/métodos , Radiobiologia , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Probabilidade , Dosagem Radioterapêutica
10.
Metrologia ; 552018.
Artigo em Inglês | MEDLINE | ID: mdl-30983634

RESUMO

A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using an alpha-gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10B-enriched boron carbide totally absorbed the neutrons in a monochromatic beam, and the rate of absorbed neutrons was determined by counting 478 keV gamma rays from neutron capture on 10B with calibrated high-purity germanium detectors. A second measurement based on Bragg diffraction from a perfect silicon crystal was performed to determine the mean de Broglie wavelength of the beam to a precision of 0.024%. With these measurements, the detection efficiency of a neutron monitor based on neutron absorption on 6Li was determined to an overall uncertainty of 0.058%. We discuss the principle of the alpha-gamma method and present details of how the measurement was performed including the systematic effects. We also describe how this method may be used for applications in neutron dosimetry and metrology, fundamental neutron physics, and neutron cross section measurements.

11.
Appl Radiat Isot ; 132: 212-221, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29239757

RESUMO

A white neutron beam line using back-streaming neutrons from the spallation target is under construction at China Spallation Neutron Source (CSNS). Different spectrometers, to be installed in the so-called Back-n beam line for nuclear data measurements, are also being developed in phases. The physical design of the beam line is carried out with the help of a complicated collimation system and a sophisticated neutron dump, taking the overview of the neutron beam characteristics into account. This includes energy spectrum, flux and time structure, the optimizations of neutron beam spots and in-hall background. The wide neutron energy range of 1eV-100MeV is excellent for supporting different applications, especially nuclear data measurements. At Endstation#2, which is about 80m away from the target, the main properties of the beam line include neutron flux of 106n/cm2/s, time resolution of a few per mille over nearly the entire energy range, and in-hall background of about 0.01/cm2/s for both neutron and gamma. With its first commission in late 2017, Back-n will not only be the first high-performance white neutron source in China, but also one of the best white neutron sources in the world.

12.
J Geophys Res Atmos ; 122(2): 1365-1383, 2017 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-28357174

RESUMO

It has been discussed that lightning flashes emit high-energy electrons, positrons, photons, and neutrons with single energies of several tens of MeV. In the first part of this paper we study the absorption of neutron beams in the atmosphere. We initiate neutron beams of initial energies of 350 keV, 10 MeV, and 20 MeV at source altitudes of 4 km and 16 km upward and downward and see that in all these cases neutrons reach ground altitudes and that the cross-section areas extend to several km2. We estimate that for terrestrial gamma-ray flashes approximately between 10 and 2000 neutrons per ms and m2 are possibly detectable at ground, at 6 km, or at 500 km altitude. In the second part of the paper we discuss a feedback model involving the generation and motion of electrons, positrons, neutrons, protons, and photons close to the vicinity of lightning leaders. In contrast to other feedback models, we do not consider large-scale thundercloud fields but enhanced fields of lightning leaders. We launch different photon and electron beams upward at 4 km altitude. We present the spatial and energy distribution of leptons, hadrons, and photons after different times and see that leptons, hadrons, and photons with energies of at least 40 MeV are produced. Because of their high rest mass hadrons are measurable on a longer time scale than leptons and photons. The feedback mechanism together with the field enhancement by lightning leaders yields particle energies even above 40 MeV measurable at satellite altitudes.

13.
Int J Radiat Biol ; 92(11): 665-678, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-26967573

RESUMO

To establish metabolic context for radiation sensitivity by measuring autophagic flux in two different glioblastoma (GBM) cell lines. Clonogenic survival curve analysis of U87 or U251 cells exposed to γ radiation, fast neutrons, a mixed energy neutron beam (METNB) or Auger electrons from a gadolinium neutron capture (GdNC) reaction suggested other factors, beyond a defective DNA damage response, contribute to cell death of U251 cells. Altered tumor metabolism (autophagy) was hypothesized as a factor in U251 cells' clonogenic response. Each of the four different radiation modalities induced an increase in the number of autophagosomes in both U87 and U251 cells. Changes in the number of autophagosomes can be explained by either induction of autophagy or alterations in autophagic flux so autophagic flux was assayed by p62 immunoblotting or in engineered GBM cells that stably express an autophagy marker protein, LC3B-eGFP-mCherry. Perturbations in later stages of autophagy in U251 cells corresponded with radiation sensitivity of U251 cells irradiated with 10 Gy γ rays. Establishment of altered autophagic flux is a useful biomarker for metabolic stress and provided metabolic context for radiation sensitization to 10 Gy γ rays. These results provide strong evidence for the usefulness of managing tumor cell metabolism as a tool for the enhancement of radiation therapy.


Assuntos
Autofagossomos/efeitos da radiação , Autofagia/efeitos da radiação , Dano ao DNA , Elétrons/uso terapêutico , Glioblastoma/genética , Glioblastoma/radioterapia , Autofagossomos/patologia , Linhagem Celular Tumoral , Relação Dose-Resposta à Radiação , Raios gama/uso terapêutico , Glioblastoma/patologia , Humanos , Nêutrons/uso terapêutico , Dosagem Radioterapêutica
14.
Appl Radiat Isot ; 107: 312-316, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26595774

RESUMO

The neutron beam monitoring system is indispensable to BNCT facility in order to achieve an accurate patient dose delivery. The neutron beam monitoring of a reactor-based BNCT (RB-BNCT) facility can be implemented through the instrumentation and control system of a reactor provided that the reactor power level remains constant during reactor operation. However, since the neutron flux in reactor core is highly correlative to complicated reactor kinetics resulting from such as fuel depletion, poison production, and control blade movement, some extent of variation may occur in the spatial distribution of neutron flux in reactor core. Therefore, a dedicated neutron beam monitoring system is needed to be installed in the vicinity of the beam path close to the beam exit of the RB-BNCT facility, where it can measure the BNCT beam intensity as closely as possible and be free from the influence of the objects present around the beam exit. In this study, in order to demonstrate the importance of a dedicated BNCT neutron beam monitoring system, the signals originating from the two in-core neutron detectors installed at THOR were extracted and compared with the three dedicated neutron beam monitors of the THOR BNCT facility. The correlation of the readings between the in-core neutron detectors and the BNCT neutron beam monitors was established to evaluate the improvable quality of the beam intensity measurement inferred by the in-core neutron detectors. In 29 sampled intervals within 16 days of measurement, the fluctuations in the mean value of the normalized ratios between readings of the three BNCT neutron beam monitors lay within 0.2%. However, the normalized ratios of readings of the two in-core neutron detectors to one of the BNCT neutron beam monitors show great fluctuations of 5.9% and 17.5%, respectively.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Monitoramento de Radiação/instrumentação , Terapia por Captura de Nêutron de Boro/normas , Desenho de Equipamento , Humanos , Nêutrons , Reatores Nucleares , Monitoramento de Radiação/normas , Radiometria/instrumentação
15.
Appl Radiat Isot ; 106: 129-33, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26242561

RESUMO

This paper reports the preliminary results obtained by Electron Paramagnetic Resonance (EPR) measurements on films of IRGANOX® 1076 phenols with and without low content (5% by weight) of gadolinium oxide (Gd2O3) exposed in the thermal column of the Triga Mark II reactor of LENA (Laboratorio Energia Nucleare Applicata) of Pavia (Italy). Thanks to their size, the phenolic films here presented are good devices for the dosimetry of beams with high dose gradient and which require accurate knowledge of the precise dose delivered. The dependence of EPR signal as function of neutron dose was investigated in the fluence range between 10(11) cm(-2) and 10(14) cm(-2). Linearity of EPR response was found and the signal was compared with that of commercial alanine films. Our analysis showed that gadolinium oxide (5% by weight) can enhance the thermal neutron sensitivity more than 18 times. Irradiated dosimetric films of phenolic compound exhibited EPR signal fading of about 4% after 10 days from irradiation.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Nêutrons , Fenóis/química , Calibragem
16.
Appl Radiat Isot ; 88: 203-5, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24491680

RESUMO

(33)S is a stable isotope of sulfur for which the emission of an α-particle is the dominant exit channel for neutron-induced reactions. In this work the enhancement of both the absorbed and the equivalent biologically weighted dose in a BNCT treatment with 13.5keV neutrons, due to the presence of (33)S, has been tested by means of Monte Carlo simulations. The kerma-fluence factors for the ICRU-4 tissue have been calculated using standard weighting factors. The simulations depend crucially on the scarce (33)S(n,α)(30)Si cross-section data. The presence of a high resonance at 13.5keV was established by previous authors providing discrepant resonance parameters. No experimental data below 10keV are available. All of this has motivated a proposal of experiment at the n_TOF facility at CERN. A setup was designed and tested in 2011. Some results of the successful test will be shown. The experiment is scheduled for the period November to December 2012.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Modelos Estatísticos , Aceleradores de Partículas/instrumentação , Radiometria/instrumentação , Isótopos de Enxofre/química , Isótopos de Enxofre/efeitos da radiação , Absorção de Radiação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Dosagem Radioterapêutica , Espalhamento de Radiação
17.
Appl Radiat Isot ; 88: 157-61, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24369892

RESUMO

Since 2010 the LVR-15 reactor has been gradually converted from highly enriched fuel (36wt% (235)U) to low enriched fuel with the enrichment of 19.75wt% (235)U. Paper presents influence of the core pattern changes on the neutron characteristics of the epithermal beam. The determination of neutron spectrum free in the beam was done with a set of neutron activation monitors. After the reactor conversion the change in neutron spectrum is not provable as differences are in the range of measurement errors.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Nêutrons , Reatores Nucleares/instrumentação , Radiometria/instrumentação , Urânio/análise , Desenho de Equipamento , Análise de Falha de Equipamento
18.
J Res Natl Inst Stand Technol ; 110(3): 273-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308135

RESUMO

The present paper reports on the preliminary experimental results concerning a new concept of ultracold neutron production with a single crystal converter of ortho-deuterium lying in the ground rotational state at the low temperature of about 10 K, which should make it possible to utilize a guided cold neutron beam instead of irradiating the converter material in the inside of high radiation fields. The successful observation of the clear Bragg scattering pattern from the single crystal converter and the reasonable results from the first experimental trial of the ultracold neutron production with the single crystal are shown.

19.
J Res Natl Inst Stand Technol ; 110(4): 491-4, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308173

RESUMO

Solid deuterium (sD2) will be used for the production of ultra-cold neutrons (UCN) in a new generation of UCN sources. Scattering cross sections of UCN in sD2 determine the source yield but until now have not been investigated. We report first results from transmission and scattering experiments with cold, very cold and ultra-cold neutrons on sD2 along with light transmission and Raman scattering studies showing the influence of the sD2 crystal properties.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA