Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 246
Filtrar
1.
J Colloid Interface Sci ; 677(Pt B): 352-364, 2025 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39151228

RESUMO

HYPOTHESIS: Self-driven actions, like motion, are fundamental characteristics of life. Today, intense research focuses on the kinetics of droplet motion. Quantifying macroscopic motion and exploring the underlying mechanisms are crucial in self-structuring and self-healing materials, advancements in soft robotics, innovations in self-cleaning environmental processes, and progress within the pharmaceutical industry. Usually, the driving forces inducing macroscopic motion act at the molecular scale, making their real-time and high-resolution investigation challenging. Label-free surface sensitive measurements with high lateral resolution could in situ measure both molecular-scale interactions and microscopic motion. EXPERIMENTS: We employ surface-sensitive label-free sensors to investigate the kinetic changes in a self-assembled monolayer of the trimethyl(octadecyl)azanium chloride surfactant on a substrate surface during the self-propelled motion of nitrobenzene droplets. The adsorption-desorption of the surfactant at various concentrations, its removal due to the moving organic droplet, and rebuilding mechanisms at droplet-visited areas are all investigated with excellent time, spatial, and surface mass density resolution. FINDINGS: We discovered concentration dependent velocity fluctuations, estimated the adsorbed amount of surfactant molecules, and revealed multilayer coverage at high concentrations. The desorption rate of surfactant (18.4 s-1) during the microscopic motion of oil droplets was determined by in situ differentiating between droplet visited and non-visited areas.

2.
Sensors (Basel) ; 24(20)2024 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-39460236

RESUMO

In this study, we developed an optofluidic chip consisting of a guided-mode resonance (GMR) sensor incorporated into a microfluidic chip to achieve simultaneous blood plasma separation and label-free albumin detection. A sedimentation chamber is integrated into the microfluidic chip to achieve plasma separation through differences in density. After a blood sample is loaded into the optofluidic chip in two stages with controlled flow rates, the blood cells are kept in the sedimentation chamber, enabling only the plasma to reach the GMR sensor for albumin detection. This GMR sensor, fabricated using plastic replica molding, achieved a bulk sensitivity of 175.66 nm/RIU. With surface-bound antibodies, the GMR sensor exhibited a limit of detection of 0.16 µg/mL for recombinant albumin in buffer solution. Overall, our findings demonstrate the potential of our integrated chip for use in clinical samples for biomarker detection in point-of-care applications.


Assuntos
Biomarcadores , Técnicas Biossensoriais , Microfluídica , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Biomarcadores/sangue , Humanos , Microfluídica/métodos , Microfluídica/instrumentação , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Limite de Detecção
3.
Biosensors (Basel) ; 14(10)2024 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-39451692

RESUMO

Survivin belongs to a family of proteins that promote cellular proliferation and inhibit cellular apoptosis. Its overexpression in various cancer types has led to its recognition as an important marker for cancer diagnosis and treatment. In this work, we compare two approaches for the immunochemical detection of survivin through surface-enhanced fluorescence or Raman spectroscopy using surfaces with nanowires decorated with silver nanoparticles in the form of dendrites or aggregates as immunoassays substrates. In both substrates, a two-step non-competitive immunoassay was developed using a pair of specific monoclonal antibodies, one for detection and the other for capture. The detection antibody was biotinylated and combined with streptavidin labeled with rhodamine for the detection of surface-enhanced fluorescence, while, for the detection via Raman spectroscopy, streptavidin labeled with peroxidase was used and the signal was obtained after the application of 3,3',5,5'-tetramethylbenzidine (TMB) precipitating substrate. It was found that the substrate with the silver dendrites provided higher fluorescence signal intensity compared to the substrate with the silver aggregates, while the opposite was observed for the Raman signal. Thus, the best substrate was used for each detection method. A detection limit of 12.5 pg/mL was achieved with both detection approaches along with a linear dynamic range up to 500 pg/mL, enabling survivin determination in human serum samples from both healthy and ovarian cancer patients for cancer diagnosis and monitoring purposes.


Assuntos
Prata , Análise Espectral Raman , Survivina , Prata/química , Humanos , Nanopartículas Metálicas/química , Técnicas Biossensoriais , Espectrometria de Fluorescência , Imunoensaio , Feminino , Nanoestruturas , Limite de Detecção , Neoplasias Ovarianas
4.
Micromachines (Basel) ; 15(9)2024 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-39337829

RESUMO

DNA is fundamental for storing and transmitting genetic information. Analyzing DNA or RNA base sequences enables the identification of genetic disorders, monitoring gene expression, and detecting pathogens. Traditional detection techniques like polymerase chain reaction (PCR) and next-generation sequencing (NGS) have limitations, including complexity, high cost, and the need for advanced computational skills. Therefore, there is a significant demand for enzyme-free and amplification-free strategies for rapid, low-cost, and sensitive DNA detection. DNA biosensors, especially those utilizing plasmonic nanomaterials, offer a promising solution. This study introduces a novel DNA-functionalized waveguide-enhanced nanoplasmonic optofluidic biosensor using a nanogold-linked sorbent assay for enzyme-free and amplification-free DNA detection. Integrating plasmonic gold nanoparticles (AuNPs) with a glass planar waveguide (WG) and a microfluidic channel, fabricated through cost-effective, vacuum-free methods, the biosensor achieves specific detection of complementary target DNA sequences. Utilizing a sandwich architecture, AuNPs labeled with detection DNA probes enhance sensitivity by altering evanescent wave distribution and inducing plasmon resonance modes. The biosensor demonstrated exceptional performance in DNA detection, achieving a limit of detection (LOD) of 33.1 fg/mL (4.36 fM) with a rapid response time of approximately 8 min. This ultrasensitive, rapid, and cost-effective biosensor exhibits minimal background nonspecific adsorption, making it highly suitable for clinical applications and early disease diagnosis. The innovative design and fabrication processes offer significant advantages for mass production, presenting a viable tool for precise disease diagnostics and improved clinical outcomes.

5.
ACS Appl Mater Interfaces ; 16(38): 50202-50211, 2024 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-39271662

RESUMO

Sulfonamide antibiotics were the first synthetic antibiotics on the market and still have a broad field of application. Their extensive usage, wrong disposal, and limited degradation technologies in wastewater treatment plants lead to high concentrations in the environment, resulting in a negative impact on ecosystems and an acceleration of antibiotic resistance. Although lab-based analytical methods allow for sulfonamide detection, comprehensive monitoring is hampered by the nonavailability of on-site, inexpensive sensing technologies. In this work, we exploit functionalized elastic hydrogel microparticles and their ability to easily deform upon specific binding with enzyme-coated surfaces to establish the groundwork of a biosensing assay for the fast and straightforward detection of sulfonamide antibiotics. The detection assay is based on sulfamethoxazole-functionalized hydrogel microparticles as sensor probes and the biomimetic interaction of sulfonamide analytes with their natural target enzyme, dihydropteroate synthase (DHPS). DHPS from S. pneumoniae was recombinantly produced by E. coli and covalently coupled on a glass biochip using a reactive maleic anhydride copolymer coating. Monodisperse poly(ethylene glycol) hydrogel microparticles of 50 µm in diameter were synthesized within a microfluidic setup, followed by the oriented coupling of a sulfamethoxazole derivative to the microparticle surface. In proof-of-concept experiments, sulfamethoxazole, as the most used sulfonamide antibiotic in medical applications, was demonstrated to be specifically detectable above a concentration of 10 µM. With its straightforward detection principle, this assay has the potential to be used for point-of-use monitoring of sulfonamide antibiotic contaminants in the environment.


Assuntos
Antibacterianos , Técnicas Biossensoriais , Hidrogéis , Sulfonamidas , Técnicas Biossensoriais/métodos , Hidrogéis/química , Antibacterianos/química , Antibacterianos/análise , Sulfonamidas/química , Di-Hidropteroato Sintase/metabolismo , Di-Hidropteroato Sintase/química , Sulfametoxazol/análise , Sulfametoxazol/química
6.
Biosensors (Basel) ; 14(9)2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39329784

RESUMO

This study examined applications of polarized evanescent guided wave surface-enhanced Raman spectroscopy to determine the binding and orientation of small molecules and ligand-modified nanoparticles, and the relevance of this technique to lab-on-a-chip, surface plasmon polariton and other types of field enhancement techniques relevant to Raman biosensing. A simplified tutorial on guided-wave Raman spectroscopy is provided that introduces the notion of plasmonic nanoparticle field enhancements to magnify the otherwise weak TE- and TM-polarized evanescent fields for Raman scattering on a simple plasmonic nanoparticle slab waveguide substrate. The waveguide construct is called an optical chemical bench (OCB) to emphasize its adaptability to different kinds of surface chemistries that can be envisaged to prepare optical biosensors. The OCB forms a complete spectroscopy platform when integrated into a custom-built Raman spectrograph. Plasmonic enhancement of the evanescent field is achieved by attaching porous carpets of Au@Ag core shell nanoparticles to the surface of a multi-mode glass waveguide substrate. We calibrated the OCB by establishing the dependence of SER spectra of adsorbed 4-mercaptopyridine and 4-aminobenzoic acid on the TE/TM polarization state of the evanescent field. We contrasted the OCB construct with more elaborate photonic chip devices that also benefit from enhanced evanescent fields, but without the use of plasmonics. We assemble hierarchies of matter to show that the OCB can resolve the binding of Fe2+ ions from water at the nanoscale interface of the OCB by following the changes in the SER spectra of 4MPy as it coordinates the cation. A brief introduction to magnetoplasmonics sets the stage for a study that resolves the 4ABA ligand interface between guest magnetite nanoparticles adsorbed onto host plasmonic Au@Ag nanoparticles bound to the OCB. In some cases, the evanescent wave TM polarization was strongly attenuated, most likely due to damping by inertial charge carriers that favor optical loss for this polarization state in the presence of dense assemblies of plasmonic nanoparticles. The OCB offers an approach that provides vibrational and orientational information for (bio)sensing at interfaces that may supplement the information content of evanescent wave methods that rely on perturbations in the refractive index in the region of the evanescent wave.


Assuntos
Ouro , Análise Espectral Raman , Técnicas Biossensoriais/métodos , Ouro/química , Ligantes , Nanopartículas Metálicas/química , Prata/química , Análise Espectral Raman/métodos , Ressonância de Plasmônio de Superfície
7.
J Virol Methods ; 330: 115028, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39236987

RESUMO

Addressing the need for accessible SARS-CoV-2 testing, carboxy-PEG 12-thiol functionalized gold nanoparticles conjugates were developed for rapid point-of-care (POC) detection against SARS-CoV-2 spike protein, pseudo-SARS-CoV-2, and authentic Beta SARS-CoV-2 virus particles. These conjugates leverage gold nanoparticles (AuNPs) as signal transducers, cross-linked to either angiotensin-converting enzyme 2 (ACE2) or SARS-CoV-2 spike protein receptor-binding domain (RBD) antibodies as bioreceptors and showed a distinct color shift from pink to blue. To assess their POC feasibility, the conjugates were integrated into facemasks and breathalyzers, wherein aerosolized SARS-CoV-2 antigens were successfully detected, producing a color change within 10 and 30 minutes for the breathalyzer and facemask prototypes, respectively. Furthermore, we explored quantitative analysis using varying concentrations of SARS-CoV-2 spike protein. Both conjugates demonstrated a linear relationship between blue color intensity and virus concentration, with linear ranges of 0.08-0.6 ng/mL and 0.04-0.5 ng/mL, respectively. Low limits of detection and quantification were also achieved. They exhibited specificity, responding solely to SARS-CoV-2 even in complex matrices containing diverse proteins, including the SARS-CoV-1 spike protein. Precision tests yielded coefficient of variations below 2 %, showcasing their remarkable reproducibility. This work presents a promising approach for rapid, sensitive, and specific POC detection of SARS-CoV-2 paving the way for improved pandemic response and management.


Assuntos
COVID-19 , Ouro , Nanopartículas Metálicas , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Ouro/química , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Humanos , Nanopartículas Metálicas/química , Glicoproteína da Espícula de Coronavírus/imunologia , COVID-19/diagnóstico , COVID-19/virologia , Polietilenoglicóis/química , Enzima de Conversão de Angiotensina 2/metabolismo , Compostos de Sulfidrila/química , Testes Imediatos , Anticorpos Antivirais , Sensibilidade e Especificidade
8.
Small ; : e2403560, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39212623

RESUMO

Drug toxicity assays using conventional 2D static cultures and animal studies have limitations preventing the translation of potential drugs to the clinic. The recent development of organs-on-a-chip platforms provides promising alternatives for drug toxicity/screening assays. However, most studies conducted with these platforms only utilize single endpoint results, which do not provide real-time/ near real-time information. Here, a versatile technology is presented that integrates a 3D liver-on-a-chip with a label-free photonic crystal-total internal reflection (PC-TIR) biosensor for rapid and continuous monitoring of the status of cells. This technology can detect drug-induced liver toxicity by continuously monitoring the secretion rates and levels of albumin and glutathione S-transferase α (GST-α) of a 3D liver on-a-chip model treated with Doxorubicin. The PC-TIR biosensor is based on a one-step antibody functionalization with high specificity and a detection range of 21.7 ng mL-1 to 7.83 x 103 ng mL-1 for albumin and 2.20 ng mL-1 to 7.94 x 102 ng mL-1 for GST-α. This approach provides critical advantages for the early detection of drug toxicity and improved temporal resolution to capture transient drug effects. The proposed proof-of-concept study introduces a scalable and efficient plug-in solution for organ-on-a-chip technologies, advancing drug development and in vitro testing methods by enabling timely and accurate toxicity assessments.

9.
Sensors (Basel) ; 24(16)2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39204849

RESUMO

Helicobacter pylori (H. pylori) is a common pathogen with a high prevalence of infection in human populations. The diagnosis of H. pylori infection is critical for its treatment, eradication, and prognosis. Biosensors have been demonstrated to be powerful for the rapid onsite detection of pathogens, particularly for point-of-care test (POCT) scenarios. In this work, we propose a novel optical biosensor, based on nanomaterial porous silicon (PSi) and photonic surface state Tamm Plasmon Polariton (TPP), for the detection of cytotoxin-associated antigen A (CagA) of H. pylori bacterium. We fabricated the PSi TPP biosensor, analyzed its optical characteristics, and demonstrated through experiments, with the sensing of the CagA antigen, that the TPP biosensor has a sensitivity of 100 pm/(ng/mL), a limit of detection of 0.05 ng/mL, and specificity in terms of positive-to-negative ratio that is greater than six. From these performance factors, it can be concluded that the TPP biosensor can serve as an effective tool for the diagnosis of H. pylori infection, either in analytical labs or in POCT applications.


Assuntos
Antígenos de Bactérias , Proteínas de Bactérias , Técnicas Biossensoriais , Helicobacter pylori , Silício , Técnicas Biossensoriais/métodos , Silício/química , Helicobacter pylori/imunologia , Helicobacter pylori/isolamento & purificação , Antígenos de Bactérias/imunologia , Antígenos de Bactérias/análise , Proteínas de Bactérias/imunologia , Porosidade , Humanos , Infecções por Helicobacter/diagnóstico , Infecções por Helicobacter/microbiologia
10.
Front Bioeng Biotechnol ; 12: 1315633, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39119272

RESUMO

IgM is the major circulating Ig isotype in teleost fish, showing in Antarctic fish unique features such as an extraordinary long hinge region, which plays a crucial role in antibody structure and function. In this work, we describe the replacement of the hinge region of a murine monoclonal antibody (mAb) with the peculiar hinge from Antarctic fish IgM. We use the CRISPR/Cas9 system as a powerful tool for generating the engineered mAb. Then, we assessed its functionality by using an innovative plasmonic substrate based on bimetallic nanoislands (AgAuNIs). The affinity constant of the modified mAb was 2.5-fold higher than that obtained from wild-type mAb against the specific antigen. Here, we show the suitability of the CRISPR/Cas9 method for modifying a precise region in immunoglobulin gene loci. The overall results could open a frontier in further structural modifications of mAbs for biomedical and diagnostic purposes.

11.
Macromol Rapid Commun ; : e2400471, 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39183584

RESUMO

Molecularly imprinted silica nanoparticles (SP-MIP) are synthesized for the real-time optical detection of low-molecular-weight compounds. Azo-initiator-modified silica beads are functionalized through reversible addition-fragmentation chain transfer (RAFT) polymerization, which leads to efficient control of the grafted layer. The copolymerization of methacrylic acid (MAA) and ethylene glycol dimethacrylate (EDMA) on azo initiator-coated silica particles (≈100 nm) using chain transfer agent (2-phenylprop-2-yl-dithiobenzoate) is carried out in the presence of a target analyte molecule (l-Boc-phenylalanine anilide, l-BFA). The chemical and morphological properties of SP-MIP are characterized by scanning electron microscopy, X-ray photoelectron spectroscopy, Brunauer-Emmett-Teller surface analysis, and thermogravimetric analysis. Finally, SP-MIP is located on the gold surface to be used as a biorecognition layer on the surface plasmon resonance spectrometer (SPR). The sensitivity, response time, and selectivity of SP-MIP are investigated by three similar analogous molecules (l-Boc-Tryptophan, l-Boc-Tyrosine, and l-Boc-Phenylalanine) and the imprinted particle surface showed excellent relative selectivity toward l-Boc-Phenylalanine (l-BFA) (k = 61), while the sensitivity is recorded as limit of detection = 1.72 × 10-4 m.

12.
Biosens Bioelectron ; 263: 116613, 2024 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-39084044

RESUMO

The biomimetic enzyme cascade system plays a key role in biosensing as a sophisticated signal transduction and amplification strategy. However, constructing a regulated enzyme cascade sensing system remains challenging due to the mismatch of multiple enzyme activities and poor stability. Herein, we design an efficient dual-enhanced enzyme cascade hybrid system (UFD-DEC) containing DNA-controlled nanozymes (Fe-cdDNA) and enzyme (urease) via combining the electrostatic contact effect with the hydrogel-directed confinement effect. Precise modulation of Fe-cdDNA nanozyme by DNA offers a means to control its catalytic efficiency. This regulated UFD-DEC system accelerates the reaction rate and provides remarkable stability compared with the free enzyme system. Benefiting from the plasticity properties of hydrogels, a "lab-in-a-tube" platform was constructed by encapsulating UFD-DEC in a microcentrifuge tube. Such a UFD-DEC-based hydrogel tube exhibits sufficient adaptability to profile urea when used in conjunction with a smartphone-assisted image processing algorithm, which on-site delivers urea information with a detection limit of 0.12 mmol L-1. This customizable and inexpensive miniaturized biosensor platform for monitoring urea may facilitate point-of-care testing applications.


Assuntos
Técnicas Biossensoriais , Hidrogéis , Limite de Detecção , Urease , Técnicas Biossensoriais/métodos , Hidrogéis/química , Urease/química , Ureia/análise , Ureia/química , DNA Catalítico/química , DNA/química
13.
Biosensors (Basel) ; 14(7)2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-39056608

RESUMO

The demand for accurate and efficient immunoassays calls for the development of precise, high-throughput analysis methods. This paper introduces a novel approach utilizing a weak measurement interface sensor for immunoassays, offering a solution for high throughput analysis. Weak measurement is a precise quantum measurement method that amplifies the weak value of a system in the weak interaction through appropriate pre- and post-selection states. To facilitate the simultaneous analysis of multiple samples, we have developed a chip with six flow channels capable of conducting six immunoassays concurrently. We can perform real-time immunoassay to determine the binding characteristics of spike protein and antibody through real-time analysis of the flow channel images and calculating the relative intensity. The proposed method boasts a simple structure, eliminating the need for intricate nano processes. The spike protein concentration and relative intensity curve were fitted using the Log-Log fitting regression equation, and R2 was 0.91. Utilizing a pre-transformation approach to account for slight variations in detection sensitivity across different flow channels, the present method achieves an impressive limit of detection(LOD) of 0.85 ng/mL for the SARS-CoV-2 the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein, with a system standard deviation of 5.61. Furthermore, this method has been successfully verified for monitoring molecular-specific binding processes and differentiating binding capacities.


Assuntos
Técnicas Biossensoriais , COVID-19 , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Glicoproteína da Espícula de Coronavírus/análise , Imunoensaio/métodos , Humanos , COVID-19/diagnóstico , COVID-19/virologia , Limite de Detecção , Ensaios de Triagem em Larga Escala
14.
Nanotechnology ; 35(41)2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-38991516

RESUMO

In this study, we present a nanosized biosensor based on the photobiological properties of one-dimensional (1D) topological photonic crystals (PCs). A topological structure had been designed by combining two PC structures (PC 1 and PC 2) comprised of functional material layers, Si and SiO2. These two, PC 1 and PC 2, differ in terms of the thickness and arrangement of these dielectric materials. We carried out a comparison between two distinct topological PCs: one using random PCs, and the other featuring a mirror heterostructure. Tuberculosis may be diagnosed by inserting a sensor layer into 1D topological PCs. The sensing process is based on the refractive indexes of the analytes in the sensor layer. When the 1D-topological heterostructure-based PC and its mirror-image structures are stacked together, the sensor becomes more efficient for analyte detection than the conventional PCs. The random-based topological PC outperformed the heterostructure-based topological PC in analyte sensing. Photonic media witness notable blue shifts due to the analytes' variations in refractive index. The numerical results of the sensor are computed using the transfer matrix approach. Effective results are achieved by optimizing the thicknesses of the sensor layer and dielectric layers; number of periods and incident angle. In normal incident light, the developed sensor shows a high sensitivity of 1500 nm RIU-1with a very low limit of detection in the order of 2.2 × 10-06RIU and a high-quality factor of 30 659.54.

15.
Talanta ; 279: 126563, 2024 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-39032462

RESUMO

This work describes the development of a label-free (LF) biosensing platform for the direct detection of targets based on diffractive structures fabricated with acrylamide-based hydrogels biofunctionalized with proteins and antibodies. Hydrogels containing Bovine Serum Albumin protein (BSA) with different crosslinking degrees were synthesized and characterized to find the optimal conditions for the suitable fabrication of surface relief gratings (SRGs). The bioavailability of BSA-functionalized hydrogels for the specific recognition of anti-BSA antibodies was verified by fluorescence detection. After the hydrogel-based SRG fabrication, diffraction efficiency measures at two different laser wavelengths were used for the direct LF detection of anti-BSA antibodies. The limit of detection in the sub mg L-1 range was read. Additionally, SRGs were prepared with hydrogels biofunctionalized with anti-rabbit antibodies for the direct detection of IgGs from rabbit serum, obtaining similar analytical performance without the necessity of labeling or applying amplification strategies.


Assuntos
Técnicas Biossensoriais , Hidrogéis , Imunoglobulina G , Soroalbumina Bovina , Hidrogéis/química , Técnicas Biossensoriais/métodos , Soroalbumina Bovina/química , Animais , Coelhos , Imunoglobulina G/sangue , Holografia , Propriedades de Superfície , Bovinos , Limite de Detecção
16.
Compr Rev Food Sci Food Saf ; 23(4): e13358, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38923121

RESUMO

Low-cost, reliable, and efficient biosensors are crucial in detecting residual heavy metal ions (HMIs) in food products. At present, based on distance-induced localized surface plasmon resonance of noble metal nanoparticles, enzyme-mimetic reaction of nanozymes, and chelation reaction of metal chelators, the constructed optical sensors have attracted wide attention in HMIs detection. Besides, based on the enrichment and signal amplification strategy of nanomaterials on HMIs and the construction of electrochemical aptamer sensing platforms, the developed electrochemical biosensors have overcome the plague of low sensitivity, poor selectivity, and the inability of multiplexed detection in the optical strategy. Moreover, along with an in-depth discussion of these different types of biosensors, a detailed overview of the design and application of innovative devices based on these sensing principles was provided, including microfluidic systems, hydrogel-based platforms, and test strip technologies. Finally, the challenges that hinder commercial application have also been mentioned. Overall, this review aims to establish a theoretical foundation for developing accurate and reliable sensing technologies and devices for HMIs, thereby promoting the widespread application of biosensors in the detection of HMIs in food.


Assuntos
Técnicas Biossensoriais , Contaminação de Alimentos , Metais Pesados , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Metais Pesados/análise , Contaminação de Alimentos/análise , Análise de Alimentos/métodos , Análise de Alimentos/instrumentação
17.
ACS Synth Biol ; 13(6): 1600-1620, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38842483

RESUMO

Antimicrobial resistance (AMR) poses a critical global One Health concern, ensuing from unintentional and continuous exposure to antibiotics, as well as challenges in accurate contagion diagnostics. Addressing AMR requires a strategic approach that emphasizes early stage prevention through screening in clinical, environmental, farming, and livestock settings to identify nonvulnerable antimicrobial agents and the associated genes. Conventional AMR diagnostics, like antibiotic susceptibility testing, possess drawbacks, including high costs, time-consuming processes, and significant manpower requirements, underscoring the need for intelligent, prompt, and on-site diagnostic techniques. Nanoenabled artificial intelligence (AI)-supported smart optical biosensors present a potential solution by facilitating rapid point-of-care AMR detection with real-time, sensitive, and portable capabilities. This Review comprehensively explores various types of optical nanobiosensors, such as surface plasmon resonance sensors, whispering-gallery mode sensors, optical coherence tomography, interference reflection imaging sensors, surface-enhanced Raman spectroscopy, fluorescence spectroscopy, microring resonance sensors, and optical tweezer biosensors, for AMR diagnostics. By harnessing the unique advantages of these nanoenabled smart biosensors, a revolutionary paradigm shift in AMR diagnostics can be achieved, characterized by rapid results, high sensitivity, portability, and integration with Internet-of-Things (IoT) technologies. Moreover, nanoenabled optical biosensors enable personalized monitoring and on-site detection, significantly reducing turnaround time and eliminating the human resources needed for sample preservation and transportation. Their potential for holistic environmental surveillance further enhances monitoring capabilities in diverse settings, leading to improved modern-age healthcare practices and more effective management of antimicrobial treatments. Embracing these advanced diagnostic tools promises to bolster global healthcare capacity to combat AMR and safeguard One Health.


Assuntos
Inteligência Artificial , Técnicas Biossensoriais , Nanoestruturas , Técnicas Biossensoriais/métodos , Nanoestruturas/química , Humanos , Antibacterianos/farmacologia , Farmacorresistência Bacteriana/genética
18.
Biosens Bioelectron ; 260: 116425, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-38824703

RESUMO

Cancer antigen 15-3 (CA 15-3) is a crucial marker used in the diagnosis and monitoring of breast cancer (BC). The demand for early and precise cancer detection has grown, making the creation of biosensors that are highly sensitive and specific essential. This review paper provides a thorough examination of the progress made in optical and electrochemical biosensors for detecting the cancer biomarker CA 15-3. We focus on explaining their fundamental principles, sensitivity, specificity, and potential for point-of-care applications. The performance attributes of these biosensors are assessed by considering their limits of detection, reaction times, and operational stability, while also making comparisons to conventional methods of CA 15-3 detection. In addition, we explore the incorporation of nanomaterials and innovative transducer components to improve the performance of biosensors. This paper conducts a thorough examination of recent studies to identify the existing obstacles. It also suggests potential areas for future research in this fast progressing field.The paper provides insights into their advancement and utilization to enhance patient outcomes. Both categories of biosensors provide significant promise for the detection of CA 15-3 and offer distinct advantages compared to conventional analytical approaches.


Assuntos
Biomarcadores Tumorais , Técnicas Biossensoriais , Neoplasias da Mama , Técnicas Eletroquímicas , Mucina-1 , Humanos , Neoplasias da Mama/diagnóstico , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Feminino , Técnicas Eletroquímicas/métodos , Biomarcadores Tumorais/análise , Biomarcadores Tumorais/sangue , Mucina-1/análise
19.
Micromachines (Basel) ; 15(5)2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38793154

RESUMO

This paper presents a biosensor based on the resonant optical tunneling effect (ROTE) for detecting a carcinoembryonic antigen (CEA). In this design, sensing is accomplished through the interaction of the evanescent wave with the CEA immobilized on the sensor's surface. When CEA binds to the anti-CEA, it alters the effective refractive index (RI) on the sensor's surface, leading to shifts in wavelength. This shift can be identified through the cascade coupling of the FP cavity and ROTE cavity in the same mode. Experimental results further show that the shift in resonance wavelength increases with the concentration of CEA. The biosensor responded linearly to CEA concentrations ranging from 1 to 5 ng/mL with a limit of detection (LOD) of 0.5 ng/mL and a total Q factor of 9500. This research introduces a new avenue for identifying biomolecules and cancer biomarkers, which are crucial for early cancer detection.

20.
Biosens Bioelectron ; 260: 116413, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-38815464

RESUMO

An optical photonic biosensor for the detection of microcystin (MC) has been developed using an aptamer-immobilized interpenetrating polymeric network (IPNaptamer) intertwined with solid-state cholesteric liquid crystals (CLCsolids). The IPN was constructed with a polyacrylic acid hydrogel (PAA). Aptamer immobilization enhances polarity while blocking hydrogen bonding between the carboxylic groups of PAA-IPN hydrogel, thereby increasing the swelling ratio of the PAA-IPN hydrogel. This leads to an expansion in the helical pitch of the corresponding IPNaptamer-CLCsolid biosensor chip and results in a red-shift in the reflected color. Upon exposure to an aqueous MC solution, the IPNaptamer-CLCsolid biosensor chip exhibits aptamer-mediated engulfment of MC, resulting in reduced polarity of the IPNaptamer complex and a consequential blue-shift in the biosensor chip color occurred. The wavelength shift of the IPNaptamer-CLCsolid biosensor chip demonstrates a linear change with an increase in MC concentration from 3.8 to 150 nM, with a limit of detection of 0.88 nM. This novel optical biosensor is characterized by its low cost, simplicity, selectivity, and sensitivity, offering a promising strategy for designing similar toxin biosensors through the modification of biological receptors.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Limite de Detecção , Microcistinas , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Microcistinas/análise , Aptâmeros de Nucleotídeos/química , Cristais Líquidos/química , Resinas Acrílicas/química , Hidrogéis/química , Desenho de Equipamento , Fótons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA