Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
BMC Nurs ; 23(1): 590, 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39183262

RESUMO

BACKGROUND: Retinopathy of prematurity (ROP) is a leading cause of avoidable blindness in children, particularly in Latin America, where hyperoxia is a significant risk factor. This study evaluated resource availability and use for administering and monitoring supplemental oxygen in Mexico. METHODS: In 2011, an observational study in which 32 government neonatal intensive care units (NICUs) across Mexico were visited. Data collected included occupancy, staffing levels, and equipment to deliver and monitor supplemental oxygen. Preterm infants receiving oxygen were observed. In 2023, 13 NICUs were revisited, and similar data collected. Staffing levels were benchmarked against Argentinian and US recommendations. RESULTS: In 2011, only 38% of NICUs had adequate medical and staffing levels to meet recommended cot-to-staff ratios for all shifts. Staffing ratios were worse during weekends and at night than during weekdays. Only 25.5% of cots had blenders, and 80.1% had saturation monitors. 153 infants were observed 87% of whom were being monitored. Upper and lower oxygen saturations were ≥ 96% in 53%, and ≤ 89% in 8%, respectively. Alarm settings were inadequate, as 38% and 32% of upper and lower alarms were switched off and 16% and 53% were incorrectly set, respectively. In the 13 NICUs with data from 2011  and 2023, cot-to-staff ratios deteriorated over time, and in 2023 no unit had recommended ratios for all shifts. Equipment provision did not change, with similar proportions of babies in oxygen being monitored (79% 2011; 75% 2023). Rates of hyperoxia decreased slightly from 54% in 2011 to 49% in 2023. More upper alarms were set (46% 2011; 75% 2023), but a higher proportion were incorrectly set (52% 2011; 68% 2023). CONCLUSIONS: Between 2011 and 2023, cot-to-staff ratios worsened, and equipment for safe oxygen delivery and monitoring remained insufficient. Despite available monitoring equipment, oxygen saturations often exceeded recommended levels, and alarms were frequently not set or incorrectly configured. Urgent improvements are needed in healthcare workforce numbers and practices, along with ensuring adequate equipment for safe oxygen delivery.

2.
Biosens Bioelectron ; 262: 116549, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38971037

RESUMO

Continuous oxygenation monitoring of machine-perfused organs or transposed autologous tissue is not currently implemented in clinical practice. Oxygenation is a critical parameter that could be used to verify tissue viability and guide corrective interventions, such as perfusion machine parameters or surgical revision. This work presents an innovative technology based on oxygen-sensitive, phosphorescent metalloporphyrin allowing continuous and non-invasive oxygen monitoring of ex-vivo perfused vascularized fasciocutaneous flaps. The method comprises a small, low-energy optical transcutaneous oxygen sensor applied on the flap's skin paddle as well as oxygen sensing devices placed into the tubing. An intermittent perfusion setting was designed to study the response time and accuracy of this technology over a total of 54 perfusion cycles. We further evaluated correlation between the continuous oxygen measurements and gold-standard perfusion viability metrics such as vascular resistance, with good agreement suggesting potential to monitor graft viability at high frequency, opening the possibility to employ feedback control algorithms in the future. This proof-of-concept study opens a range of research and clinical applications in reconstructive surgery and transplantation at a time when perfusion machines undergo rapid clinical adoption with potential to improve outcomes across a variety of surgical procedures and dramatically increase access to transplant medicine.


Assuntos
Técnicas Biossensoriais , Oxigênio , Perfusão , Procedimentos de Cirurgia Plástica , Oxigênio/metabolismo , Humanos , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Animais , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Desenho de Equipamento , Retalhos Cirúrgicos , Suínos
3.
Acta Neurochir (Wien) ; 166(1): 240, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38814348

RESUMO

BACKGROUND: Intracranial pressure (ICP) monitoring plays a key role in patients with traumatic brain injury (TBI), however, cerebral hypoxia can occur without intracranial hypertension. Aiming to improve neuroprotection in these patients, a possible alternative is the association of Brain Tissue Oxygen Pressure (PbtO2) monitoring, used to detect PbtO2 tension. METHOD: We systematically searched PubMed, Embase and Cochrane Central for RCTs comparing combined PbtO2 + ICP monitoring with ICP monitoring alone in patients with severe or moderate TBI. The outcomes analyzed were mortality at 6 months, favorable outcome (GOS ≥ 4 or GOSE ≥ 5) at 6 months, pulmonary events, cardiovascular events and sepsis rate. RESULTS: We included 4 RCTs in the analysis, totaling 505 patients. Combined PbtO2 + ICP monitoring was used in 241 (47.72%) patients. There was no significant difference between the groups in relation to favorable outcome at 6 months (RR 1.17; 95% CI 0.95-1.43; p = 0.134; I2 = 0%), mortality at 6 months (RR 0.82; 95% CI 0.57-1.18; p = 0.281; I2 = 34%), cardiovascular events (RR 1.75; 95% CI 0.86-3.52; p = 0.120; I2 = 0%) or sepsis (RR 0.75; 95% CI 0.25-2.22; p = 0.604; I2 = 0%). The risk of pulmonary events was significantly higher in the group with combined PbtO2 + ICP monitoring (RR 1.44; 95% CI 1.11-1.87; p = 0.006; I2 = 0%). CONCLUSIONS: Our findings suggest that combined PbtO2 + ICP monitoring does not change outcomes such as mortality, functional recovery, cardiovascular events or sepsis. Furthermore, we found a higher risk of pulmonary events in patients undergoing combined monitoring.


Assuntos
Lesões Encefálicas Traumáticas , Pressão Intracraniana , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Encéfalo/fisiopatologia , Lesões Encefálicas Traumáticas/mortalidade , Lesões Encefálicas Traumáticas/terapia , Lesões Encefálicas Traumáticas/fisiopatologia , Hipertensão Intracraniana/etiologia , Hipertensão Intracraniana/diagnóstico , Pressão Intracraniana/fisiologia , Monitorização Fisiológica/métodos , Monitorização Neurofisiológica/métodos , Oxigênio/análise , Oxigênio/metabolismo
4.
Neurosurg Rev ; 47(1): 222, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758384

RESUMO

To assess whether monitoring brain tissue oxygen partial pressure (PbtO2) or employing intracranial pressure (ICP)/cerebral perfusion pressure (CCP)-guided management improves patient outcomes, including mortality, hospital length of stay (LOS), mean daily ICP and mean daily CCP during the intensive care unit(ICU)stay. We searched the Web of Science, EMBASE, PubMed, Cochrane Library, and MEDLINE databases until December 12, 2023. Prospective randomized controlled and cohort studies were included. A meta-analysis was performed for the primary outcome measure, mortality, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Eleven studies with a total of 37,492 patients were included. The mortality in the group with PbtO2 was 29.0% (odds ratio: 0.73;95% confidence interval [CI]:0.56-0.96; P = 0.03; I = 55%), demonstrating a significant benefit. The overall hospital LOS was longer in the PbtO2 group than that in the ICP/CPP group (mean difference:2.03; 95% CI:1.03-3.02; P<0.0001; I = 39%). The mean daily ICP in the PbtO2 monitoring group was lower than that in the ICP/CPP group (mean difference:-1.93; 95% CI: -3.61 to -0.24; P = 0.03; I = 41%). Moreover, PbtO2 monitoring did not improve the mean daily CPP (mean difference:2.43; 95%CI: -1.39 to 6.25;P = 0.21; I = 56%).Compared with ICP/CPP monitoring, PbtO2 monitoring reduced the mortality and the mean daily ICP in patients with severe traumatic brain injury; however, no significant effect was noted on the mean daily CPP. In contrast, ICP/CPP monitoring alone was associated with a short hospital stay.


Assuntos
Lesões Encefálicas Traumáticas , Encéfalo , Pressão Intracraniana , Oxigênio , Humanos , Lesões Encefálicas Traumáticas/mortalidade , Lesões Encefálicas Traumáticas/diagnóstico , Lesões Encefálicas Traumáticas/terapia , Circulação Cerebrovascular/fisiologia , Pressão Intracraniana/fisiologia , Tempo de Internação , Monitorização Fisiológica/métodos , Oxigênio/metabolismo , Oxigênio/sangue , Pressão Parcial , Prognóstico
5.
ACS Sens ; 9(5): 2383-2394, 2024 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-38687178

RESUMO

Oxygen plays a central role in aerobic metabolism, and while many approaches have been developed to measure oxygen concentration in biological environments over time, monitoring spatiotemporal changes in dissolved oxygen levels remains challenging. To address this, we developed a ratiometric core-shell organosilica nanosensor for continuous, real-time optical monitoring of oxygen levels in biological environments. The nanosensors demonstrate good steady state characteristics (KpSV = 0.40 L/mg, R2 = 0.95) and respond reversibly to changes in oxygen concentration in buffered solutions and report similar oxygen level changes in response to bacterial cell growth (Escherichia coli) in comparison to a commercial bulk optode-based sensing film. We further demonstrated that the oxygen nanosensors could be distributed within a growing culture of E. coli and used to record oxygen levels over time and in different locations within a static culture, opening the possibility of spatiotemporal monitoring in complex biological systems.


Assuntos
Escherichia coli , Oxigênio , Oxigênio/metabolismo , Oxigênio/análise , Escherichia coli/metabolismo , Escherichia coli/isolamento & purificação , Técnicas Biossensoriais/métodos , Nanotecnologia , Compostos de Organossilício/química
6.
Neurol Sci ; 45(7): 3051-3059, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38353849

RESUMO

Monitoring intracranial pressure (ICP) is pivotal in the management of severe traumatic brain injury (TBI), but secondary brain injuries can arise despite normal ICP levels. Cerebral tissue oxygenation monitoring (PbtO2) may detect neuronal tissue infarction thresholds, enhancing neuroprotection. We performed a systematic review and meta-analysis to evaluate the effects of combined cerebral tissue oxygenation (PbtO2) and ICP compared to isolated ICP monitoring in patients with TBI. PubMed, Embase, Cochrane, and Web of Sciences databases were searched for trials published up to June 2023. A total of 16 studies comprising 37,820 patients were included. ICP monitoring was universal, with additional placement of PbtO2 in 2222 individuals (5.8%). The meta-analysis revealed a reduction in mortality (OR 0.57, 95% CI 0.37-0.89, p = 0.01), a greater likelihood of favorable outcomes (OR 2.28, 95% CI 1.66-3.14, p < 0.01), and a lower chance of poor outcomes (OR 0.51, 95% CI 0.34-0.79, p < 0.01) at 6 months for the PbtO2 plus ICP group. However, these patients experienced a longer length of hospital stay (MD 2.35, 95% CI 0.50-4.20, p = 0.01). No significant difference was found in hospital mortality rates (OR 0.81, 95% CI 0.61-1.08, p = 0.16) or intensive care unit length of stay (MD 2.46, 95% CI - 0.11-5.04, p = 0.06). The integration of PbtO2 to ICP monitoring improved mortality outcomes and functional recovery at 6 months in patients with TBI. PROSPERO (International Prospective Register of Systematic Reviews) CRD42022383937; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=383937.


Assuntos
Lesões Encefálicas Traumáticas , Pressão Intracraniana , Humanos , Lesões Encefálicas Traumáticas/terapia , Lesões Encefálicas Traumáticas/mortalidade , Lesões Encefálicas Traumáticas/fisiopatologia , Pressão Intracraniana/fisiologia , Monitorização Neurofisiológica/métodos , Oxigênio/metabolismo , Oxigênio/sangue , Encéfalo/metabolismo , Encéfalo/fisiopatologia , Monitorização Fisiológica/métodos
7.
Front Neurol ; 14: 1284098, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38099068

RESUMO

Objectives: Literature on invasive neuromonitoring and bilateral decompressive craniectomies (BDC) in patients with refractory status epilepticus (RSE)-mediated hypoxic-ischemic brain injury (HIBI) is limited. Neuromonitoring can guide decision making and treatment escalation. Methods and results: We report a case of a 17 years-old male who was admitted to our hospital's intensive care unit for RSE. HIBI was detected on neuroimaging on this patient's second day of admission after he developed central diabetes insipidus (DI). Invasive neuromonitoring revealed raised intracranial pressure (ICP) and brain hypoxia as measured by reduced brain tissue oxygen tension (PbtO2). Treatments were escalated in a tiered fashion, including administration of hyperosmolar agents, analgesics, sedatives, and a neuromuscular blocking drug. Eventually, BDC was performed as a salvage therapy as a means of controlling refractory ICP crisis in the setting of diffuse cerebral edema (DCE) following HIBI. Discussion: SE-mediated HIBI can result in refractory ICP crisis. Neuromonitoring can help identify secondary brain injury (SBI), guide treatment strategies, including surgical interventions, and may lead to better outcomes.

8.
Chembiochem ; 24(24): e202300421, 2023 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-37782555

RESUMO

Galactose Oxidase (GalOx) has gained significant interest in biocatalysis due to its ability for selective oxidation beyond the natural oxidation of galactose, enabling the production of valuable derivatives. However, the practical application of GalOx has been hindered by the limited availability of active and stable biocatalysts, as well as the inherent biochemical limitations such as oxygen (O2 ) dependency and the need for activation. In this study, we addressed these challenges by immobilizing GalOx into agarose-based and Purolite supports to enhance its activity and stability. Additionally, we identified and quantified the oxygen supply limitation into solid catalysts by intraparticle oxygen sensing showing a trade-off between the amount of protein loaded onto the solid support and the catalytic effectiveness of the immobilized enzyme. Furthermore, we coimmobilized a heme-containing protein along with the enzyme to function as an activator. To evaluate the practical application of the immobilized GalOx, we conducted the oxidation of galactose in an instrumented aerated reactor. The results showcased the efficient performance of the immobilized enzyme in the 8 h reaction cycle. Notably, the GalOx immobilized into dextran sulfate-activated agarose exhibited improved stability, overcoming the need for a soluble activator supply, and demonstrated exceptional performance in galactose oxidation. These findings offer promising prospects for the utilization of GalOx in technical biocatalytic applications.


Assuntos
Enzimas Imobilizadas , Hemeproteínas , Enzimas Imobilizadas/metabolismo , Galactose Oxidase/metabolismo , Galactose , Sefarose , Biocatálise , Hemeproteínas/metabolismo , Oxigênio
9.
Anesthesiol Clin ; 41(1): 39-78, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36872007

RESUMO

Traumatic brain injury is a devastating event associated with substantial morbidity. Pathophysiology involves the initial trauma, subsequent inflammatory response, and secondary insults, which worsen brain injury severity. Management entails cardiopulmonary stabilization and diagnostic imaging with targeted interventions, such as decompressive hemicraniectomy, intracranial monitors or drains, and pharmacological agents to reduce intracranial pressure. Anesthesia and intensive care requires control of multiple physiologic variables and evidence-based practices to reduce secondary brain injury. Advances in biomedical engineering have enhanced assessments of cerebral oxygenation, pressure, metabolism, blood flow, and autoregulation. Many centers employ multimodality neuromonitoring for targeted therapies with the hope to improve recovery.


Assuntos
Lesões Encefálicas Traumáticas , Lesões Encefálicas , Humanos , Unidades de Terapia Intensiva , Encéfalo , Cuidados Críticos
10.
J Neurosurg Pediatr ; : 1-11, 2022 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-35623367

RESUMO

OBJECTIVE: Severe traumatic brain injury (TBI) is a leading cause of disability and death in the pediatric population. While intracranial pressure (ICP) monitoring is the gold standard in acute neurocritical care following pediatric severe TBI, brain tissue oxygen tension (PbtO2) monitoring may also help limit secondary brain injury and improve outcomes. The authors hypothesized that pediatric patients with severe TBI and ICP + PbtO2 monitoring and treatment would have better outcomes than those who underwent ICP-only monitoring and treatment. METHODS: Patients ≤ 18 years of age with severe TBI who received ICP ± PbtO2 monitoring at a quaternary children's hospital between 1998 and 2021 were retrospectively reviewed. The relationships between conventional measurements of TBI were evaluated, i.e., ICP, cerebral perfusion pressure (CPP), and PbtO2. Differences were analyzed between patients with ICP + PbtO2 versus ICP-only monitoring on hospital and pediatric intensive care unit (PICU) length of stay (LOS), length of intubation, Pediatric Intensity Level of Therapy scale score, and functional outcome using the Glasgow Outcome Score-Extended (GOS-E) scale at 6 months postinjury. RESULTS: Forty-nine patients, including 19 with ICP + PbtO2 and 30 with ICP only, were analyzed. There was a weak negative association between ICP and PbtO2 (ß = -0.04). Conversely, there was a strong positive correlation between CPP ≥ 40 mm Hg and PbtO2 ≥ 15 and ≥ 20 mm Hg (ß = 0.30 and ß = 0.29, p < 0.001, respectively). An increased number of events of cerebral PbtO2 < 15 mm Hg or < 20 mm Hg were associated with longer hospital (p = 0.01 and p = 0.022, respectively) and PICU (p = 0.015 and p = 0.007, respectively) LOS, increased duration of mechanical ventilation (p = 0.015 when PbtO2 < 15 mm Hg), and an unfavorable 6-month GOS-E score (p = 0.045 and p = 0.022, respectively). An increased number of intracranial hypertension episodes (ICP ≥ 20 mm Hg) were associated with longer hospital (p = 0.007) and PICU (p < 0.001) LOS and longer duration of mechanical ventilation (p < 0.001). Lower minimum hourly and average daily ICP values predicted favorable GOS-E scores (p < 0.001 for both). Patients with ICP + PbtO2 monitoring experienced longer PICU LOS (p = 0.018) compared to patients with ICP-only monitoring, with no significant GOS-E score difference between groups (p = 0.733). CONCLUSIONS: An increased number of cerebral hypoxic episodes and an increased number of intracranial hypertension episodes resulted in longer hospital LOS and longer duration of mechanical ventilator support. An increased number of cerebral hypoxic episodes also correlated with less favorable functional outcomes. In contrast, lower minimum hourly and average daily ICP values, but not the number of intracranial hypertension episodes, were associated with more favorable functional outcomes. There was a weak correlation between ICP and PbtO2, supporting the importance of multimodal invasive neuromonitoring in pediatric severe TBI.

11.
J Intensive Care Soc ; 23(2): 191-202, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35615230

RESUMO

Traumatic brain injury (TBI) is common and potentially devastating. Traditional examination-based patient monitoring following TBI may be inadequate for frontline clinicians to reduce secondary brain injury through individualized therapy. Multimodal neurologic monitoring (MMM) offers great potential for detecting early injury and improving outcomes. By assessing cerebral oxygenation, autoregulation and metabolism, clinicians may be able to understand neurophysiology during acute brain injury, and offer therapies better suited to each patient and each stage of injury. Hence, we offer this primer on brain tissue oxygen monitoring, pressure reactivity index monitoring and cerebral microdialysis. This narrative review serves as an introductory guide to the latest clinically-relevant evidence regarding key neuromonitoring techniques.

12.
Photoacoustics ; 26: 100345, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35295617

RESUMO

Chronic wounds and amputations are common in chronic kidney disease patients needing hemodialysis (HD). HD is often complicated by drops in blood pressure (BP) called intra-dialytic hypotension. Whether intra-dialytic hypotension is associated with detectable changes in foot perfusion, a risk factor for wound formation and impaired healing remains unknown. Photoacoustic (PA) imaging is ideally suited to study perfusion changes. We scanned the feet of 20 HD and 11 healthy subjects. HD patients were scanned before and after a dialysis session whereas healthy subjects were scanned twice at rest and once after a 10 min exercise period while BP was elevated. Healthy (r = 0.70, p < 0.0001) and HD subjects (r = 0.43, p < 0.01) showed a significant correlation between PA intensity and systolic BP. Furthermore, HD cohort showed a significantly reduced PA response to changes in BP compared to the healthy controls (p < 0.0001), showing that PA can monitor hemodynamic changes due to changes in BP.

13.
J Neurosurg ; 135(6): 1799-1806, 2021 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-34852324

RESUMO

OBJECTIVE: Brain tissue oxygen monitoring combined with intracranial pressure (ICP) monitoring in patients with severe traumatic brain injury (sTBI) may confer better outcomes than ICP monitoring alone. The authors sought to investigate this using a national database. METHODS: The National Trauma Data Bank from 2013 to 2017 was queried to identify patients with sTBI who had an external ventricular drain or intraparenchymal ICP monitor placed. Patients were stratified according to the placement of an intraparenchymal brain tissue oxygen tension (PbtO2) monitor, and a 2:1 propensity score matching pair was used to compare outcomes in patients with and those without PbtO2 monitoring. Sensitivity analyses were performed using the entire cohort, and each model was adjusted for age, sex, Glasgow Coma Scale score, Injury Severity Score, presence of hypotension, insurance, race, and hospital teaching status. The primary outcome of interest was in-hospital mortality, and secondary outcomes included ICU length of stay (LOS) and overall LOS. RESULTS: A total of 3421 patients with sTBI who underwent ICP monitoring were identified. Of these, 155 (4.5%) patients had a PbtO2 monitor placed. Among the propensity score-matched patients, mortality occurred in 35.4% of patients without oxygen monitoring and 23.4% of patients with oxygen monitoring (OR 0.53, 95% CI 0.33-0.85; p = 0.007). The unfavorable discharge rates were 56.3% and 47.4%, respectively, in patients with and those without oxygen monitoring (OR 1.41, 95% CI 0.87-2.30; p = 0.168). There was no difference in overall LOS, but patients with PbtO2 monitoring had a significantly longer ICU LOS and duration of mechanical ventilation. In the sensitivity analysis, PbtO2 monitoring was associated with decreased odds of mortality (OR 0.56, 95% CI 0.37-0.84) but higher odds of unfavorable discharge (OR 1.59, 95% CI 1.06-2.40). CONCLUSIONS: When combined with ICP monitoring, PbtO2 monitoring was associated with lower inpatient mortality for patients with sTBI. This supports the findings of the recent Brain Oxygen Optimization in Severe Traumatic Brain Injury phase 2 (BOOST 2) trial and highlights the importance of the ongoing BOOST3 trial.


Assuntos
Lesões Encefálicas Traumáticas/fisiopatologia , Encéfalo/fisiopatologia , Pressão Intracraniana/fisiologia , Monitorização Fisiológica/métodos , Oxigênio/análise , Adulto , Química Encefálica , Lesões Encefálicas Traumáticas/mortalidade , Bases de Dados Factuais , Feminino , Mortalidade Hospitalar , Humanos , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Prognóstico , Pontuação de Propensão , Adulto Jovem
14.
Sci Total Environ ; 743: 140402, 2020 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-32758807

RESUMO

The determination of the hydrogen peroxide dosage scheme that minimizes hydrogen peroxide consumption while meeting the specified treatment outcome is crucial for Fenton and photo-Fenton processes. The challenge is building a methodology that provides the optimal dosage profile. However, the lack of detailed dynamic models prevents exploiting model-based optimization methods that have proved successful in other applications. Thus, this work addresses this challenge by providing a problem formulation identifying and discussing objectives and constraints, and the nature of the optimal solution. From this point, the work presents a novel dosage model and a consequent methodology aimed at experimentally optimizing the dosage profile along a discretized time horizon following recipe optimization concepts. The approach is parallel to the numerical solution of the model-based optimization problem posed by hydrogen peroxide dosage. The proposed methodology is validated in the remediation of a Paracetamol (PCT) solution, and the obtained results are assessed and discussed in regard of the evolution of the concentration of hydrogen peroxide, the contaminant (PCT), and Total Organic Carbon (TOC). The concentration of dissolved oxygen (DO), which is also monitored, allows providing a more comprehensive explanation of the nature of the process.

15.
Cureus ; 12(2): e7115, 2020 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-32257661

RESUMO

Introduction This article is a retrospective analysis of the neurosurgical census at our institution to determine an optimal threshold for brain tissue oxygenation (PbtO2). The use of brain tissue oxygen monitoring has been in place for approximately three decades but data suggesting optimal thresholds to improve outcomes have been lacking. Though there are multiple modalities to monitor cerebral oxygenation, the monitoring of brain tissue oxygen tension has been deemed the gold standard. Still, it is not clear exactly how reductions in PbtO2 should be treated or what appropriate thresholds to treat might be. The aim of our study was to determine if our threshold of 28 mmHg for a good functional outcome could be correlated to the Glasgow Coma Scale (GCS) and Glasgow Outcome Scale (GOS). Methods A retrospective analysis of the Arrowhead Regional Medical Center (ARMC) Neurosurgery Census was performed. Patients from 2017-2019 who had placement of Licox® cerebral oxygen monitoring sensors (Integra® Lifesciences, Plainsboro Township, New Jersey) were included in the analysis. Fifteen patients were consecutively identified, all of which presented with traumatic brain injury (TBI). Data on age, gender, days in the intensive care unit (ICU), days before discharge or end of medical care, admission GCS, hospital length of stay, GOS, maximum and minimum PbtO2 values for five days following insertion, minimum and maximum intracranial pressures (ICPs), and brain temperature were included for analysis. Patient data were separated into two groups; those with consistently higher PbtO2 scores (≥ 28 mmHg; n = 7) and those with inconsistent/lower PbtO2 scores (< 28 mmHg; n = 8). Standard student t-tests were used to find potential statistical differences between the groups (α = 0.05). Results There were seven patients in the consistently high PbtO2 category (≥ 28 mmHg) and eight patients in the inconsistent/low PbtO2 category (<28 mmHg). The average maximum and minimum PbtO2 for the group displaying worse outcomes (as defined by GCS/GOS) was 23.0 mmHg and 14 mmHg, respectively. Those with consistent Day 2 PbtO2 scores of ≥ 28 mmHg had significantly higher GCS scores at discharge/end of medical care (p < 0.05). Average GCS for the patient group with >28 mmHg PbtO2 averaged over Days 2-5 group was 11.4 (n=7). Average GCS for the <28 group was 7.0 (n=8). The GCS for the >28 group was 63% higher than found in the <28 group (p = 0.03). GOS scores were significantly higher in those with consistently higher PbtO2 (≥ 28) than those with lower PbtO2 scores (< 28). The averages were 3.5 in the higher PbtO2 group as compared to 2 in the lower PbtO2 group. Conclusion Along with ICP monitors and monitoring in the assessment of CPP, brain tissue oxygenation allows yet another metric by which to optimize treatment in TBI patients. At our institution, a PbtO2 level of ≥ 28 mmHg is targeted in order to facilitate a good functional outcome in TBI patients. Keeping patients at this level improves GCS and GOS at discharge/end of medical treatment.

16.
Cell Transplant ; 29: 963689719893936, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32024377

RESUMO

Medical devices for cell therapy can be improved through prevascularization. In this work we study the vascularization of a porous polymer device, previously used by our group for pancreatic islet transplantation with results indicating improved glycemic control. Oxygen partial pressure within such devices was monitored non-invasively using an optical technique. Oxygen-sensitive tubes were fabricated and placed inside devices prior to subcutaneous implantation in nude mice. We tested the hypothesis that vascularization will be enhanced by administration of the pro-angiogenic factor hydrogen sulfide (H2S). We found that oxygen dynamics were unique to each implant and that the administration of H2S does not result in significant changes in perfusion of the devices as compared with control. These observations suggest that vascular perfusion and density are not necessarily correlated, and that the rate of vascularization was not enhanced by the pro-angiogenic agent.


Assuntos
Terapia Baseada em Transplante de Células e Tecidos/métodos , Sulfeto de Hidrogênio/uso terapêutico , Animais , Gasometria , Equipamentos e Provisões , Transplante das Ilhotas Pancreáticas/métodos , Masculino , Camundongos , Camundongos Nus , Oxigênio/análise , Engenharia Tecidual/métodos
17.
N Biotechnol ; 56: 27-37, 2020 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-31704414

RESUMO

Design and development of scale-down approaches, such as microbioreactor (µBR) technologies with integrated sensors, are an adequate solution for rapid, high-throughput and cost-effective screening of valuable reactions and/or production strains, with considerably reduced use of reagents and generation of waste. A significant challenge in the successful and widespread application of µBRs in biotechnology remains the lack of appropriate software and automated data interpretation of µBR experiments. Here, it is demonstrated how mathematical models can be usedas helpful tools, not only to exploit the capabilities of microfluidic platforms, but also to reveal the critical experimental conditions when monitoring cascade enzymatic reactions. A simplified mechanistic model was developed to describe the enzymatic reaction of glucose oxidase and glucose in the presence of catalase inside a commercial microfluidic platform with integrated oxygen sensor spots. The proposed model allowed an easy and rapid identification of the reaction mechanism, kinetics and limiting factors. The effect of fluid flow and enzyme adsorption inside the microfluidic chip on the optical sensor response and overall monitoring capabilities of the presented platform was evaluated via computational fluid dynamics (CFD) simulations. Remarkably, the model predictions were independently confirmed for µL- and mL- scale experiments. It is expected that the mechanistic models will significantly contribute to the further promotion of µBRs in biocatalysis research and that the overall study will create a framework for screening and evaluation of critical system parameters, including sensor response, operating conditions, experimental and microbioreactor designs.


Assuntos
Reatores Biológicos , Catalase/metabolismo , Glucose Oxidase/metabolismo , Técnicas Analíticas Microfluídicas , Modelos Biológicos , Fibras Ópticas , Biocatálise
18.
Clin Perinatol ; 46(3): 417-433, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31345538

RESUMO

Formerly, assessing oxygenation relied on recognizing cyanosis; however, this is unreliable. Also, in neonates, a pink color, suggesting absence of severe hypoxemia, is difficult to assess. An objective and continuous assessment of oxygenation is necessary. Currently, this is best achieved noninvasively by transcutaneous partial pressure of oxygen (PTcO2) monitoring or pulse oximetry. Because both PTcO2 and oxygen saturation monitors (pulse oximeters) may display erroneous measurements, thorough understanding of their operating principles is required. Also, clinicians must recognize the range of values expected in healthy neonates. In this article, data on these issues are reviewed.


Assuntos
Monitorização Fisiológica/métodos , Oximetria/métodos , Oxigênio/sangue , Humanos , Lactente
19.
ACS Appl Mater Interfaces ; 10(48): 41026-41034, 2018 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-30404434

RESUMO

We present a new concept for a wearable oxygen (O2) sensor for transcutaneous O2 pressure (tcpO2) monitoring by combining the technologies of luminescent gas sensing and wearable devices. O2 monitoring has been exhaustively studied given its central role in diagnosing various diseases. The ability to quantify the physiological distribution and real-time dynamics of O2 from the subcellular to the macroscopic level is required to fully understand mechanisms associated with both normal physiological and pathological conditions. Despite its profound biological and clinical importance, few effective methods exist for noninvasively quantifying O2 in a physiological setting. The wearable sensor developed here consists of three components: a luminescent sensing film attached onto skin by a carbon tape, an organic light-emitting diode (OLED) as a light source, and an organic photodiode (OPD) as a light detector. All the components are solution-processable and integrated on a plane in a bandage-like configuration. To verify the performance, tcpO2 variations by pressure-induced occlusion were measured in the lower arm and a thumb by the wearable sensor, and the results were comparable to those measured by a commercial instrument. In addition to its flexibility, other features of this sensor render it a potential low-cost solution for the simultaneous monitoring of tcpO2 in any part of a body.


Assuntos
Desenho de Equipamento , Oxigênio/sangue , Dispositivos Eletrônicos Vestíveis , Monitorização Transcutânea dos Gases Sanguíneos/instrumentação , Monitorização Transcutânea dos Gases Sanguíneos/métodos , Humanos , Pele/irrigação sanguínea , Pele/metabolismo
20.
Respir Care ; 63(7): 900-906, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29717098

RESUMO

BACKGROUND: High electrode temperature during transcutaneous monitoring is associated with skin burns in extremely premature infants. We evaluated the accuracy and precision of CO2 and O2 measurements using lower transcutaneous electrode temperatures below 42°C. METHODS: We enrolled 20 neonates. Two transcutaneous monitors were placed simultaneously on each neonate, with one electrode maintained at 42°C and the other randomized to temperatures of 38, 39, 40, 41, and 42°C. Arterial blood was collected twice at each temperature. RESULTS: At the time of arterial blood sampling, values for transcutaneously measured partial pressure of CO2 (PtcCO2 ) were not significantly different among test temperatures. There was no evidence of skin burning at any temperature. For PtcCO2 , Bland-Altman analyses of all test temperatures versus 42°C showed good precision and low bias. Transcutaneously measured partial pressure of O2 (PtcO2 ) values trended arterial values but had large negative bias. CONCLUSION: Transcutaneous electrode temperatures as low as 38°C allow an assessment of PtcCO2 as accurate as that with electrodes at 42°C.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/instrumentação , Eletrodos , Recém-Nascido Prematuro , Temperatura , Monitorização Transcutânea dos Gases Sanguíneos/métodos , Feminino , Humanos , Recém-Nascido , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA