Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Rev Med Inst Mex Seguro Soc ; 62(1): 1-9, 2024 Jan 08.
Artigo em Espanhol | MEDLINE | ID: mdl-39110813

RESUMO

Background: The quality of the spirometry is estimated with criteria of acceptability and repeatability. The repeatability criteria accepted by consensus is < 0.150 L. Objective: To know the repeatability in quality A spirometry. Material and methods: Analytical cross-sectional design. The demographic variables and the 3 best spirometry curves with normal, suggestive of restriction and bronchial obstruction profiles were obtained from consecutive subjects of both genders from 18 to 80 years of age. The repeatability was analyzed with the mean difference (bias) and the intraclass correlation coefficient. Results: 630 curves from 210 subjects were accepted. Group age 60 ± 15 years. Female predominance 113 (53.8%), occupation: domestic services 61 (29%), and diagnosed with chronic obstructive pulmonary disease: 70 (33.4%). The differences in the curves were < 0.150 L. The mean difference (bias) and the intraclass correlation coefficient (95% confidence interval, 95% CI) of the forced expiratory volume in the first second were 1 vs. 2 maneuver: -0.01 (0.13, -0.14), 0.997 (95% CI 0.996, 0.998); 2 vs. 3 maneuver: 0.00 (0.13, -0.13), 0.997 (95% CI 0.996, 0.998), and maneuver 1 vs. 3: -0.00 (0.16, -0.17), 0.995 (95% CI 0.994, 0.996). Forced vital capacity: 1 vs. 2 maneuver: -0.01 (0.17, -0.18), 0.996 (95% CI 0.995, 0.997); 2 vs. 3 maneuver: 0.01 (0.17, -0.16), 0.997 (95% CI 0.0.996, 0.998), and maneuver 1 vs. 3: -0.00 (0.18, -0.19), 0.996 (95% CI 0.995, 0.997). Conclusion: The repeatability obtained in spirometry with quality A validates the use of the repeatability criterion of 0.150 L.


Introducción: la calidad de la espirometría se estima con criterios de aceptabilidad y repetitividad. La repetitividad aceptada por consenso es < 0.150 L. Objetivo: conocer la repetitividad en espirometrías de calidad A. Material y métodos: diseño transversal analítico. Se obtuvieron las variables demográficas y las 3 mejores curvas de espirometría con perfil normal, que sugiriera restricción y obstrucción bronquial de sujetos consecutivos de ambos géneros de 18 a 80 años. La repetitividad se analizó con la diferencia de medias (sesgo) y el coeficiente de correlación intraclase. Resultados: se aceptaron 630 curvas de 210 sujetos. Edad grupal 60 ± 15 años. Predominio femenino 113 (53.8%), ocupación: servicios domésticos 61 (29%) y con enfermedad pulmonar obstructiva crónica 70 (33.4%). Las diferencias en las curvas fueron < 0.150 L. Las diferencias medias (sesgo) y el coeficiente de correlación intraclase (intervalo de confianza al 95%, IC 95%) del volumen espiratorio forzado en el primer segundo fueron: maniobra 1 frente a 2: −0.01 (0.13, −0.14), 0.997 (IC 95% 0.996, 0.998); maniobra 2 frente a 3: 0.00 (0.13, −0.13), 0.997 (IC 95% 0.996, 0.998), y maniobra 1 frente a 3: −0.00 (0.16, −0.17), 0.995 (IC 95% 0.994, 0.996). La capacidad vital forzada: maniobra 1 frente a 2: −0.01 (0.17, −0.18), 0.996 (IC 95% 0.995, 0.997); maniobra 2 frente a 3: 0.01 (0.17, −0.16), 0.997 (IC 95% 0.0.996, 0.998), y maniobra 1 frente a 3: −0.00 (0.18, −0.19), 0.996 (IC 95% 0.995, 0.997). Conclusión: la repetitividad obtenida en espirometrías con calidad A valida el uso del criterio de repetitividad de 0.150 L.


Assuntos
Espirometria , Humanos , Estudos Transversais , Espirometria/normas , Espirometria/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Reprodutibilidade dos Testes , Adolescente , Adulto Jovem , Idoso de 80 Anos ou mais , Volume Expiratório Forçado , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia
2.
Respir Care ; 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38772682

RESUMO

BACKGROUND: High-flow tracheal oxygen (HFTO) is being used as supportive therapy during weaning in tracheostomized patients difficult to wean from invasive mechanical ventilation. There is, however, no clinical evidence for such a strategy. Therefore, we conducted a systematic review to summarize studies evaluating the physiologic effects of HFTO during tracheostomy-facilitated weaning and to identify potential areas for future research in this field. METHODS: Observational and interventional studies on critically ill subjects weaning from mechanical ventilation via tracheostomy published until December 22, 2022, were eligible. Studies on high-flow oxygen, only in children, non-human models or animals, on clinical outcome only, abstracts without full-text availability, case reports, and reviews were excluded. Main outcomes were end-expiratory lung volume (EELV) and tidal volume using electrical impedance tomography, respiratory effort assessed by esophageal manometry, work of breathing and neuroventilatory drive as assessed by electrical activity of the diaphragm (EAdi) signal, airway pressure (Paw), oxygenation (PaO2 /FIO2 or SpO2 /FIO2 ), breathing frequency, tidal volume, and PaCO2 . RESULTS: In total, 1,327 references were identified, of which 5 were included. In all studies, HFTO was administered with flow 50 L/min and compared to conventional O2 therapy in a crossover design. The total average duration of invasive ventilation at time of measurements ranged from 11-27 d. In two studies, PaO2 /FIO2 and mean Paw were higher with HFTO. EELV, tidal volumes, esophageal pressure swings, and EAdi were similar during high-flow tracheal oxygen and conventional O2 therapy. CONCLUSIONS: The main physiological effect of HFTO as compared to conventional O2 therapy in tracheostomized subjects weaning from mechanical ventilation was improved oxygenation that is probably flow-dependent. Respiratory effort, lung aeration, neuroventilatory drive, and ventilation were similar for HFTO and conventional O2 therapy. Future studies on HFTO should be performed early in the weaning process and should evaluate its effect on sputum clearance and patient-centered outcomes like dyspnea.

3.
Respir Res ; 25(1): 135, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509592

RESUMO

INTRODUCTION: Computed tomography (CT) is routinely employed on the evaluation of dyspnea, yet limited data exist on its assessment of diaphragmatic muscle. This study aimed to determine the capability of CT in identifying structural changes in the diaphragm among patients with ultrasound-confirmed diaphragmatic dysfunction. METHODS: Diaphragmatic ultrasounds conducted between 2018 and 2021 at our center in Marseille, France, were retrospectively collected. Diaphragmatic pillars were measured on CT scans at the L1 level and the celiac artery. Additionally, the difference in height between the two diaphragmatic domes in both diaphragmatic dysfunction cases and controls was measured and compared. RESULTS: A total of 65 patients were included, comprising 24 with diaphragmatic paralysis, 13 with diaphragmatic weakness, and 28 controls. In the case group (paralysis and weakness) with left dysfunctions (n = 24), the CT thickness of the pillars at the level of L1 and the celiac artery was significantly thinner compared with controls (2.0 mm vs. 7.4 mm and 1.8 mm vs. 3.1 mm, p < 0.001 respectively). Significantly different values were observed for paralysis (but not weakness) in the right dysfunction subgroup (n = 15) (2.6 mm vs. 7.4 mm and 2.2 mm vs. 3.8 mm, p < 0.001 respectively, for paralysis vs. controls). Regardless of the side of dysfunction, a significant difference in diaphragmatic height was observed between cases and controls (7.70 cm vs. 1.16 cm and 5.51 cm vs. 1.16 cm, p < 0.001 for right and left dysfunctions, respectively). Threshold values determined through ROC curve analyses for height differences between the two diaphragmatic domes, indicative of paralysis or weakness in the right dysfunctions, were 4.44 cm and 3.51 cm, respectively. Similarly for left dysfunctions, the thresholds were 2.70 cm and 2.48 cm, respectively, demonstrating good performance (aera under the curve of 1.00, 1.00, 0.98, and 0.79, respectively). CONCLUSION: In cases of left diaphragmatic dysfunction, as well as in paralysis associated with right diaphragmatic dysfunction, CT revealed thinner pillars. Additionally, a notable increase in the difference in diaphragmatic height demonstrated a strong potential to identify diaphragmatic dysfunction, with specific threshold values.


Assuntos
Diafragma , Debilidade Muscular , Humanos , Diafragma/diagnóstico por imagem , Estudos Retrospectivos , Ultrassonografia/métodos , Paralisia , Tomografia Computadorizada por Raios X , Tomografia
4.
Front Physiol ; 14: 1220463, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37822681

RESUMO

Introduction: The influence of lung disease on the diaphragm has been poorly studied. The study aimed to evaluate the diaphragm morphology (height and thickness) in single-lung transplantation (SLTx), using computed tomography (CT), by assessing the evolution of the hemidiaphragm of the transplanted and the native side. Methods: Patients who underwent single lung transplantation in our center (Marseille, France) between January 2009 and January 2022 were retrospectively included. Thoracic or abdominal CT scans performed before and the closest to and at least 3 months after the surgery were used to measure the diaphragm crus thickness and the diaphragm dome height. Results: 31 patients mainly transplanted for emphysema or pulmonary fibrosis were included. We demonstrated a significant increase in diaphragm crus thickness on the side of the transplanted lung, with an estimated difference of + 1.25 mm, p = <0.001, at the level of the celiac artery, and + 0.90 mm, p < 0.001, at the level of the L1 vertebra while no significant difference was observed on the side of the native lung. We showed a significant reduction in the diaphragm height after SLTx on the transplanted side (-1.20 cm, p = 0.05), while no change on the native side (+0.02 cm, p = 0.88). Conclusion: After a SLTx, diaphragmatic morphology significantly changed on the transplanted lung, while remaining altered on the native lung. These results highlights that an impaired lung may have a negative impact on its diaphragm. Replacement with a healthy lung can promote the recovery of the diaphragm to its anatomical morphology, reinforcing the close relationship between these two organs.

5.
Respir Res ; 24(1): 259, 2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37898765

RESUMO

INTRODUCTION: The diaphragm function assessed by ultrasound has been well-studied in COPD, asthma, and intensive care. However, there are only a few studies on diffuse interstitial lung disease, while dyspnea and quality of life are major issues in the management that may depend on the diaphragm. METHODS: We retrospectively included idiopathic pulmonary fibrosis (IPF) patients followed in our center (Marseille, France) between January 2020 and February 2023 who underwent diaphragmatic ultrasound. Our objectives were to describe the diaphragmatic function of IPFs compared to healthy controls and to correlate with clinical, functional, and lung density on CT-scan. RESULTS: 24 IPF patients and 157 controls were included. The diaphragmatic amplitude in IPF was increased at rest (median of 2.20 cm vs 1.88 cm on the right, p < 0.007, and 2.30 cm vs 1.91 cm on the left, p < 0.03, in IPF and controls respectively) and decreased in deep breathing (median of 4.85 cm vs 5.45 cm on the right, p < 0.009, and 5.10 cm vs 5.65 cm on the left, p < 0.046, in IPF and controls respectively). Diaphragmatic thickness was significantly reduced at rest on the right side (median of 1.75 mm vs 2.00 mm, p < 0.02, in IPF and controls respectively) and in deep breathing on both sides compared to controls (mean of 3.82 mm vs 4.15 mm on the right, p < 0.02, and 3.53 mm vs 3.94 mm, on the left, p < 0.009, in IPF and controls respectively). Diaphragmatic amplitude in deep breathing was moderate to strongly correlated with FVC, DLCO, and 6MWT and negatively correlated with the dyspnea and lung density on CT scan. CONCLUSION: The diaphragmatic amplitude and thickness were impaired in IPF compared to controls. Diaphragmatic amplitude is the parameter best correlated with clinical, functional, and lung density criteria. Further studies are needed to determine if diaphragmatic amplitude can be a prognostic factor in IPF.


Assuntos
Diafragma , Fibrose Pulmonar Idiopática , Humanos , Estudos Retrospectivos , Diafragma/diagnóstico por imagem , Qualidade de Vida , Fibrose Pulmonar Idiopática/diagnóstico por imagem , Dispneia , Pulmão/diagnóstico por imagem
6.
J Clin Med ; 12(2)2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36675344

RESUMO

Background: Recirculation during veno-venous extracorporeal membrane oxygenation reduces extracorporeal oxygen exchange and patient oxygenation. To minimize recirculation and maximize oxygen delivery (DO2) the interaction of cannulation, ECMO flow and cardiac output requires careful consideration. We investigated this interaction in an observational trial. Methods: In 19 patients with acute respiratory distress syndrome and ECMO, we measured recirculation with the ultrasound dilution technique and calculated extracorporeal oxygen transfer (VO2), extracorporeal oxygen delivery (DO2) and patient oxygenation. To assess the impact of cardiac output (CO), we included CO measurement through pulse contour analysis. Results: In all patients, there was a median recirculation rate of approximately 14−16%, with a maximum rate of 58%. Recirculation rates >35% occurred in 13−14% of all cases. In contrast to decreasing extracorporeal gas exchange with increasing ECMO flow and recirculation, patient oxygenation increased with greater ECMO flows. High CO diminished recirculation by between 5−20%. Conclusions: Extracorporeal gas exchange masks the importance of DO2 and its effects on patients. We assume that increasing DO2 is more important than reduced VO2. A negative correlation of recirculation to CO adds to the complexity of this phenomenon. Patient oxygenation may be optimized with the direct measurement of recirculation.

7.
Respir Med Case Rep ; 38: 101683, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35711721

RESUMO

Surgical correction of abdominal muscle diastasis may decrease intra-abdominal volume and increase intra-abdominal pressure. The induced changes may ultimately lead to respiratory compromise. In abdominoplasty, one of the most frequently performed esthetic procedures, those changes are believed to be transient and clinically insignificant. We describe a case where acute change in respiratory physiology after abdominoplasty led to severe respiratory failure with significantly decreased pulmonary compliance in a young and otherwise healthy patient. In this case mechanical ventilation failed to improve compliance, and reversal of abdominoplasty was required to restitute pulmonary function.

8.
J Investig Med ; 70(5): 1247-1257, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35190486

RESUMO

The area under the expiratory flow-volume (AEX-FV) loop has been evaluated before as a spirometric tool for assessing respiratory functional impairment. We computed the AEX-FV curves in spirometry tests performed on 20,313 participants in the National Health and Nutrition Examination Survey (NHANES) study.We analyzed 108,939 spirometry tests performed between 2007 and 2012 (5964 children; 14,349 adults). In these tests, we computed the three areas from existing NHANES raw data on instantaneous expiratory flows measured at 0.01 s intervals.Mean best-trial measurements for AEX-FV were 3.4 in boys, 2.8 in girls, 11.8 in men and 7.7 L2/s in women. We characterized indices of central tendency and dispersion of the measurements (eg, means and fifth percentiles-lower limits of normal) by age group (children vs adults), gender, race or ethnicity group and effort grading. Simple regression equations using logarithmic transformations of the above areas and using age, gender and height as inputs provided good predictive ability for the variable AEX-FV.Regular, digital spirometry could and should make available to clinicians and researchers the area under the curves for flow versus volume graph, providing additional tools in our armamentarium to evaluate ventilatory impairments and patterns, and possibly respiratory disability.


Assuntos
Volume Expiratório Forçado , Doenças Respiratórias , Espirometria , Adulto , Criança , Feminino , Humanos , Masculino , Inquéritos Nutricionais , Valores de Referência , Doenças Respiratórias/diagnóstico , Espirometria/métodos
9.
Rev Med Inst Mex Seguro Soc ; 59(6): 473-481, 2021 11 01.
Artigo em Espanhol | MEDLINE | ID: mdl-34905321

RESUMO

Background: At high altitude the gas exchange is impaired, in the moderate altitude of Mexico City they are not yet defined. Objective: To characterize the gas exchange in the moderate altitude of Mexico City. Material and methods: Through an analytical cross-sectional study, subjects born and inhabitants of Mexico City, both genders, aged 20 to 59 years without cardiopulmonary disease, were studied. Their demographic variables, simple spirometry and arterial blood gas were recorded. Differences in variables were calculated with one-way ANOVA for independent groups and Bonferroni adjustment. p < 0.05 was accepted as significant. Results: 335 subjects were studied, 168 (50.15%) men. Group age 45 ± 11 years old, body mass index 22.97 ± 1.54 Kg/m2. Forced expiratory volume ratio in the first second / Forced vital capacity (FEV1/FVC) 91.58 ± 12.86%. The arterial oxygen pressure was: 66 ± 5.02 mmHg, carbon dioxide: 32.07 ± 2.66 mmHg, arterial oxygen saturation: 93.0 3 ± 1.80%, and hemoglobin: 14.07 ± 1.52 gr/dL. Conclusions: The arterial oxygen pressure and carbon dioxide are lowered at the Mexico City altitude.


Introducción: en las grandes altitudes, el intercambio gaseoso suele estar deteriorado; en la altitud moderada de la Ciudad de México esto no está aún plenamente definido. Objetivo: caracterizar el intercambio gaseoso en la altitud moderada de la Ciudad de México. Material y métodos: mediante un estudio transversal analítico se estudiaron sujetos nacidos y habitantes de la Ciudad de México, de ambos géneros, con edades de 20 a 59 años sin enfermedad cardiopulmonar. Se registraron sus variables demográficas, espirometría simple y de gasometría arterial. Las diferencias en las variables se calcularon con ANOVA de una vía para grupos independientes y ajuste de Bonferroni. Una p < 0.05 se aceptó como significativa. Resultados: se estudiaron 335 sujetos, de los cuales 168 (50.15%) fueron hombres, la edad grupal fue de 45 ± 11 años, con índice de masa corporal 22.97 ± 1.54 Kg/m2. La relación volumen espiratorio forzado en el primer segundo/ Capacidad vital forzada (VEF1/CVF) de 91.58 ± 12.86%. La presión arterial de oxígeno fue de 66 ± 5.02 mmHg, el bióxido de carbono: 32.07 ± 2.66 mmHg, la saturación arterial de oxígeno: 93.03 ± 1.80% y la hemoglobina: 14.07 ± 1.52 gr/dL. Conclusiones: la presión arterial de oxígeno y del bióxido de carbono están disminuidos a la altura de la Ciudad de México.


Assuntos
Estudos Transversais , Adulto , Feminino , Volume Expiratório Forçado , Humanos , Masculino , México , Pessoa de Meia-Idade , Saturação de Oxigênio , Espirometria , Capacidade Vital
10.
Front Physiol ; 12: 762688, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34955883

RESUMO

This review focuses on the advances in the understanding of the pathophysiology of ventilator-induced and acute lung injury that have been afforded by technological development of imaging methods over the last decades. Examples of such advances include the establishment of regional lung mechanical strain as a determinant of ventilator-induced lung injury, the relationship between alveolar recruitment and overdistension, the regional vs. diffuse nature of pulmonary involvement in acute respiratory distress syndrome (ARDS), the identification of the physiological determinants of the response to recruitment interventions, and the pathophysiological significance of metabolic alterations in the acutely injured lung. Taken together, these advances portray multimodality imaging as the next frontier to both advance knowledge of the pathophysiology of these conditions and to tailor treatment to the individual patient's condition.

11.
Rev. Méd. Inst. Mex. Seguro Soc ; 59(6): 473-481, dic. 2021. tab
Artigo em Espanhol | LILACS | ID: biblio-1354772

RESUMO

Introducción: en las grandes altitudes, el intercambio gaseoso suele estar deteriorado; en la altitud moderada de la Ciudad de México esto no está aún plenamente definido. Objetivo: caracterizar el intercambio gaseoso en la altitud moderada de la Ciudad de México. Material y métodos: mediante un estudio transversal analítico se estudiaron sujetos nacidos y habitantes de la Ciudad de México, de ambos géneros, con edades de 20 a 59 años sin enfermedad cardiopulmonar. Se registraron sus variables demográficas, espirometría simple y de gasometría arterial. Las diferencias en las variables se calcularon con ANOVA de una vía para grupos independientes y ajuste de Bonferroni. Una p < 0.05 se aceptó como significativa. Resultados: se estudiaron 335 sujetos, de los cuales 168 (50.15%) fueron hombres, la edad grupal fue de 45 ± 11 años, con índice de masa corporal 22.97 ± 1.54 Kg/m2. La relación volumen espiratorio forzado en el primer segundo/Capacidad vital forzada (VEF1/CVF) de 91.58 ± 12.86%. La presión arterial de oxígeno fue de 66 ± 5.02 mmHg, el bióxido de carbono: 32.07 ± 2.66 mmHg, la saturación arterial de oxígeno: 93.03 ± 1.80% y la hemoglobina: 14.07 ± 1.52 gr/dL. Conclusiones: la presión arterial de oxígeno y del bióxido de carbono están disminuidos a la altura de la Ciudad de México.


Background: At high altitude the gas exchange is impaired, in the moderate altitude of Mexico City they are not yet defined. Objective: To characterize the gas exchange in the moderate altitude of Mexico City. Material and methods: Through an analytical cross-sectional study, subjects born and inhabitants of Mexico City, both genders, aged 20 to 59 years without cardiopulmonary disease, were studied. Their demographic variables, simple spirometry and arterial blood gas were recorded. Differences in variables were calculated with one-way ANOVA for independent groups and Bonferroni adjustment. p < 0.05 was accepted as significant. Results: 335 subjects were studied, 168 (50.15%) men. Group age 45 ± 11 years old, body mass index 22.97 ± 1.54 Kg/m2. Forced expiratory volume ratio in the first second / Forced vital capacity (FEV1/FVC) 91.58 ± 12.86%. The arterial oxygen pressure was: 66 ± 5.02 mmHg, carbon dioxide: 32.07 ± 2.66 mmHg, arterial oxygen saturation: 93.0 3 ± 1.80%, and hemoglobin: 14.07 ± 1.52 gr/dL. Conclusions: The arterial oxygen pressure and carbon dioxide are lowered at the Mexico City altitude.


Assuntos
Humanos , Masculino , Feminino , Doença Cardiopulmonar , Gasometria , Pressão Arterial , Testes de Função Respiratória , Espirometria , Volume Expiratório Forçado , Circulação Pulmonar , Estudos Transversais , Fenômenos Fisiológicos Circulatórios e Respiratórios
12.
Clin J Am Soc Nephrol ; 16(11): 1686-1694, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34750161

RESUMO

BACKGROUND AND OBJECTIVES: Many kidney transplant recipients suffer from fatigue and poor health-related quality of life. Airflow limitation may be an underappreciated comorbidity among kidney transplant recipients, which could contribute to fatigue and lower health-related quality of life in this population. In this study, we compared the prevalence of airflow limitation between kidney transplant recipients and healthy controls and investigated associations of airflow limitation with fatigue and health-related quality of life in kidney transplant recipients. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Data from the ongoing TransplantLines Biobank and Cohort study were used. Airflow limitation was defined as forced exhaled volume in 1 second less than the fifth percentile of the general population. Fatigue and health-related quality of life were assessed using checklist individual strength 20 revised (CIS20-R) and Short Form-36 (SF-36) questionnaires. RESULTS: A total of 539 kidney transplant recipients (58% men; mean age 56±13 years) and 244 healthy controls (45% men; mean age 57±10 years) were included. Prevalence of airflow limitation was higher in kidney transplant recipients than in healthy controls (133 [25%] versus 25 [10%]). In multinomial regression models, airflow limitation was independently associated with fatigue severity (odds ratio moderate fatigue, 1.68; 95% confidence interval, 0.92 to 3.09 and odds ratio severe fatigue, 2.51; 95% confidence interval, 1.39 to 4.55; P=0.007) and lower physical health-related quality of life (-0.11 SDs; 95% confidence interval, -0.19 to -0.02; P=0.01) in kidney transplant recipients. In exploratory mediation analyses, fatigue accounted for 79% of the association of airflow limitation with physical health-related quality of life. CONCLUSIONS: Airflow limitation is common among kidney transplant recipients. Its occurrence is associated with more than two times higher risk of severe fatigue, and it is associated with lower physical health-related quality of life. Mediation analyses suggest that airflow limitation causes fatigue, which in turn, decreases physical health-related quality of life. CLINICAL TRIAL REGISTRY NAME AND REGISTRATION NUMBER: TransplantLines: The Transplantation Biobank, NCT03272841 PODCAST: This article contains a podcast at https://www.asn-online.org/media/podcast/CJASN/2021_11_08_CJN06600521.mp3.


Assuntos
Fadiga/epidemiologia , Fadiga/fisiopatologia , Transplante de Rim , Qualidade de Vida , Adulto , Idoso , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Inquéritos e Questionários
13.
J Investig Med ; 69(5): 1027-1034, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33574095

RESUMO

In pulmonary function testing by spirometry, bronchodilator responsiveness (BDR) evaluates the degree of volume and airflow improvement in response to an inhaled short-acting bronchodilator (BD). The traditional, binary categorization (present vs absent BDR) has multiple pitfalls and limitations. To overcome these limitations, a novel classification that defines five categories (negative, minimal, mild, moderate and marked BDR), and based on % and absolute changes in forced expiratory volume in 1 s (FEV1), has been recently developed and validated in patients with chronic obstructive pulmonary disease, and against multiple objective and subjective measurements. In this study, working on several large spirometry cohorts from two different institutions (n=31 598 tests), we redefined the novel BDR categories based on delta post-BD-pre-BD FEV1 % predicted values. Our newly proposed BDR partition is based on several distinct intervals for delta post-BD-pre-BD % predicted FEV1 using Global Lung Initiative predictive equations. In testing, training and validation cohorts, the model performed well in all BDR categories. In a validation set that included only normal baseline spirometries, the partition model had a higher rate of misclassification, possibly due to unrestricted BD use prior to baseline testing. A partition that uses delta % predicted FEV1 with the following intervals ≤0%, 0%-2%, 2%-4%, 4%-8% and >8% may be a valid and easy-to-use tool for assessing BDR in spirometry. We confirmed in our cohorts that these thresholds are characterized by low variance and that they are generally gender-independent and race-independent. Future validation in other cohorts and in other populations is needed.


Assuntos
Broncodilatadores , Volume Expiratório Forçado , Doença Pulmonar Obstrutiva Crônica , Broncodilatadores/uso terapêutico , Humanos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Espirometria , Capacidade Vital
14.
Rev. Paul. Pediatr. (Ed. Port., Online) ; 39: e2019322, 2021. tab, graf
Artigo em Inglês, Português | LILACS, Sec. Est. Saúde SP | ID: biblio-1136759

RESUMO

ABSTRACT Objective: To evaluate factors associated with the performance of children and adolescents with cystic fibrosis (CF) in the Modified Shuttle Test (MST) and compare it with healthy children and adolescents. Methods: This is a cross-sectional study, with children and adolescents divided into two groups: cystic fibrosis (CFG) and control (CG). Variables evaluated in the MST: walking distance, test level, heart rate variation (∆Hr), post-test mean arterial pressure (MAP Pt) and peripheral oxygen saturation variation (∆SPO2). Statistical analysis included Mann Whitney and Spearman coefficient tests, being significant p<0.05. Results: Sixty individuals aged 6-16 years old were evaluated. Anthropometric data was similar between groups. Differences between groups were shown for: baseline heart rate (BHr), peak heart rate (PHr), ∆Hr, recovery heart rate (RHr), post-test respiratory rate (PtBr), saturation variables, peripheral oxygen level (SpO2B) and level test. The ∆Hr and MAP Pt had a moderate positive correlation with distance and level test for both groups (respectively: r=0.6 / p<0.001; r=0.6 / p<0.001). In CFG, the level test had a significant association (r=0.4 - p=0.02) with %FEV1. Conclusions: Children with cystic fibrosis presented functional limitation in the Modified Shuttle Test, which was influenced by lung function.


RESUMO Objetivo: Avaliar os fatores que estão associados ao desempenho de crianças e adolescentes com fibrose cística (FC) no teste modificado de Shuttle (MST) e compará-los com os de crianças e adolescentes saudáveis. Métodos: Estudo de corte transversal com crianças e adolescentes divididos em dois grupos: grupo controle (GC) e grupo FC (GFC). As variáveis avaliadas no MST foram: distância caminhada, nível do teste, variação da frequência cardíaca (∆Fc), pressão arterial média pós-teste (PAMPt) e variação da saturação periférica de oxigênio (∆SpO2). Na análise dos dados, foram utilizados o Teste Mann-Whitney e o coeficiente de Spearman, sendo significante p<0,05. Resultados: Avaliaram-se 60 indivíduos (6-16 anos). Os grupos foram homogêneos em relação aos dados antropométricos. Foi observada diferença significante na frequência cardíaca basal (FcB), na frequência cardíaca de pico (FcP), na ∆Fc, na frequência cardíaca de recuperação (FcR), na frequência respiratória pós-teste (FRPt), na saturação periférica de oxigênio basal (SpO2B) e no nível do teste. A ∆Fc e a PAMPt tiveram correlação moderada positiva (respectivamente, r=0,6 / p<0,001; r=0,6 / p<0,001) com a distância caminhada e o nível do teste em ambos os grupos. No GFC o nível do teste teve associação (r=0,4 / p=0,02) com a porcentagem do predito do volume expiratório forçado do primeiro segundo (%VEF1). Conclusões: Crianças e adolescentes com FC apresentaram limitação funcional no teste modificado de Shuttle, influenciada pela função pulmonar.


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Fibrose Cística/fisiopatologia , Teste de Esforço/métodos , Aptidão Cardiorrespiratória , Desempenho Físico Funcional , Consumo de Oxigênio , Pressão Sanguínea , Estudos de Casos e Controles , Estudos Transversais , Frequência Cardíaca
15.
J Am Coll Emerg Physicians Open ; 1(6): 1450-1458, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33392548

RESUMO

OBJECTIVE: To determine the correlation between 3 lightweight portable pulse oximeter devices compared to a standard wall mount pulse oximetry device. METHODS: We performed a single-center, prospective, observational study of 4 pulse oximetry devices, 3 of which are commercially available to the public. A convenience sample of 200 emergency department (ED) patients with chief complaints of cardiopulmonary origin or a peripheral capillary oxygen saturation ≤ 94 percent were enrolled. Analysis of variance was performed to compare SpO2s and test characteristics of the 3 devices compared to control. RESULTS: Although differences in measured SpO2s were observed (P < 0.001) across groups, the differences were small (mean differences ranged from 1.00% to 1.87%). The correlation between test devices and the control were high (r range 0.70-0.79). Although the test characteristics were not perfect, the devices did have good sensitivity using a cutoff value of 94% (sensitivity ranging from 90% to 92%), which improved with lower SpO2 cutoff values to 92% (sensitivity ranging from 96% to 97%). CONCLUSION: The 3 commercially available devices were accurate enough to be clinically useful when compared to a hospital bedside monitor pulse oximeter. Consumer-grade portable pulse oximeters may be useful if overwhelming numbers of patients require oxygen saturation monitoring, such as during the COVID-19 pandemic.

16.
Yonsei Med J ; 60(1): 56-64, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30554491

RESUMO

PURPOSE: Details on the hemodynamic differences among Fontan operations remain unclear according to respiratory and cardiac cycles. This study was undertaken to investigate hemodynamic characteristics in different types of Fontan circulation by quantification of blood flow with the combined influence of cardiac and respiratory cycles. MATERIALS AND METHODS: Thirty-five patients [10 atriopulmonary connections (APC), 13 lateral tunnels (LT), and 12 extracardiac conduits (ECC)] were evaluated, and parameters were measured in the superior vena cava, inferior vena cava (IVC), hepatic vein (HV), baffles, conduits, and left and right pulmonary artery. Pulsatility index (PIx), respiratory variability index (RVI), net antegrade flow integral (NAFI), and inspiratory/expiratory blood flow (IQ/EQ) were measured by intravascular Doppler echocardiography. RESULTS: The PIx between APC and total cavopulmonary connection (TCPC; LT and ECC) showed significant differences at all interrogation points regardless of respiratory cycles. The PIxs of HVs and IVCs in APC significantly increased, compared with that in LT and ECC, and the RVI between APC and TCPC showed significant differences at all interrogation points (p<0.05). The NAFI and IQ/EQ between APC and TCPC showed significant differences at some interrogation points (p<0.05). CONCLUSION: Patients with different types of Fontan circulation show different hemodynamic characteristics in various areas of the Fontan tract, which may lead to different risks causing long-term complications. We believe the novel parameters developed in this study may be used to determine flow characteristics and may serve as a clinical basis of management in patients after Fontan operations.


Assuntos
Técnica de Fontan , Fluxo Pulsátil/fisiologia , Respiração , Adolescente , Criança , Feminino , Veias Hepáticas/fisiopatologia , Humanos , Masculino , Artéria Pulmonar/fisiopatologia , Veia Cava Inferior/fisiopatologia , Veia Cava Superior/fisiopatologia
17.
Estud. interdiscip. envelhec ; 23(1): 61-74, abr. 2018. tab
Artigo em Português | LILACS, Index Psicologia - Periódicos | ID: biblio-1006742

RESUMO

O presente estudo tem por objetivo avaliar o efeito do sobrepeso e da obesidade sobre a função pulmonar (FP) e a qualidade de vida (QV) em idosos vinculados ao Programa Estratégia de Saúde da Família (ESF) em Cruz Alta-RS. Foram avaliados cem idosos, sendo noventa mulheres. A FP foi avaliada através da Capacidade Vital Forçada (CVF), Volume Expiratório Forçado no Primeiro Segundo (VEF1 ) e Pico de Fluxo Expiratório (PFE). O questionário Medical Outcome Study 36-Item Short-Form Health Survey (SF-36) foi utilizado para avaliar a QV. Observaram-se 54 indivíduos com sobrepeso ou obesos. A FP apresentou-se dentro da normalidade. As maiores pontuações de QV foram nos domínios Capacidade Funcional (CF), Estado Geral de Saúde (EGS) e Aspectos Sociais (AS). Os indivíduos com sobrepeso e obesos apresentaram escore inferior nos domínios Vitalidade e AS quando comparado aos eutróficos (p = 0,01 e p = 0,03, respectivamente). Foram encontradas correlações inversas entre IMC e os Domínios Vitalidade (r = -0,23, p = 0,01), AS (r = -0,23, p = 0,01) e AE (r = -0,27, p = 0,01). Conclui-se que os idosos avaliados apresentaram níveis satisfatórios de FP e QV, entretanto o sobrepeso e a obesidade influenciaram negativamente a QV. (AU)


The present study aims to evaluate the influence of overweight and obesity on the pulmonary function (PF), and quality of life (QoL) in elderly people linked to the Family Health Strategy Program in Cruz Alta-RS. We evaluated hundred elderly, ninety women. The PF was measured by forced vital capacity (FVC), forced expiratory volume in the first second (FEV1 ) and peak expiratory flow (PEF). The Medical Outcome Study 36-Item Short-Form Health Survey (SF-36) was used to assess QoL. It was observed 54 people with overweight or obesity. The PF was within the normal range. The higher QL scores were in the Functional Capacity (FC), General Health (EGS), and Social Aspects (SA). The overweight, and obese individuals showed lower scores in the Vitality and SA domains when compared to the eutrophic ones (p = 0.01 and p = 0.03, respectively). There was an inverse correlation between the Pain domain and the PF. Furthermore, inverse correlations were found between BMI and Vitality (r = -0.23, p = 0.01), AS (r = -0.23, p = 0.01) and EA (r = -0.27, p = 0.01) domains. Then, it was conclude that the evaluated subjects presented satisfactory levels of PF and QoL. However, high levels of BMI negatively influence their QoL. (AU)


Assuntos
Humanos , Masculino , Feminino , Idoso , Qualidade de Vida/psicologia , Pulmão/fisiologia , Obesidade/fisiopatologia , Saúde Pública , Estudos Transversais
18.
Auton Neurosci ; 208: 150-155, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29107740

RESUMO

BACKGROUND: The deep breathing test (DB) and Valsalva maneuver (VM) are used to detect autonomic dysfunction. The VM induces sympathetically mediated changes in blood pressure (phase II late, phase IV, and recovery time) and both tests induce vagally mediated heart rate changes. There is limited information on effects of key variables, compliance with testing and the effects of non-compliance This study has twin goals of evaluating compliance with standard instructions and the effects of changes in key variables. We also evaluated the effect of position on the VM. MATERIAL AND METHODS: Forty healthy males performed DB at air exchange volumes of 50, 80, and 100% of vital lung capacity (VLC). The VM was performed at 40 and 30mmHg expiratory pressure for 15 and 10s in sitting and supine position, respectively. RESULTS: Participants performed DB at lower volumes than intended and were not able to maintain 100% VLC for the duration of the test. The DB heart rate response decreased 6.3beats/min per liter below VLC. During the VM, subjects blew at lower pressures than instructed. The VM responses were significantly larger with longer expiration durations, higher expiratory pressures and when performed sitting. Performing the VM at 40mmHg for 10s in supine position increased the odds ratio of experiencing flat-top responses. CONCLUSION: The ability of subjects to strictly comply with methodological guidelines significantly improves results. Recording of both test parameters and ensuing results is suggested.


Assuntos
Doenças do Sistema Nervoso Autônomo/diagnóstico , Postura , Respiração , Manobra de Valsalva , Pressão do Ar , Doenças do Sistema Nervoso Autônomo/fisiopatologia , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial , Cardiografia de Impedância , Frequência Cardíaca/fisiologia , Humanos , Masculino , Razão de Chances , Postura/fisiologia , Manobra de Valsalva/fisiologia , Capacidade Vital , Adulto Jovem
19.
Tuberc Respir Dis (Seoul) ; 80(4): 385-391, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28905534

RESUMO

BACKGROUND: Men with chronic obstructive pulmonary disease, have reduced endogenous testosterone levels, but the relationship between pulmonary function and endogenous testosterone levels, is inconsistent. Testicular volume is a known indicator of endogenous testosterone levels, male fertility, and male potency. In the present study, the authors investigated the relationship, between testicular volume and lung function. METHODS: One hundred and eighty-one South Korean men age 40-70, hospitalized for urological surgery, were retrospectively enrolled, irrespective of the presence of respiratory disease. Study subjects underwent pulmonary function testing, prior to procedures, and testicular volumes were measured by orchidometry. Testosterone levels of patients in blood samples collected between 7 AM and 11 AM, were measured by a direct chemiluminescent immunoassay. RESULTS: The 181 study subjects were divided into two groups, by testicular volume (≥35 mL vs. <35 mL), the larger testes group, had better lung functions (forced vital capacity [FVC]: 3.87±0.65 L vs. 3.66±0.65 L, p=0.037; forced expiratory volume in 1 second [FEV1]: 2.92±0.57 L vs. 2.65±0.61 L, p=0.002; FVC % predicted: 98.2±15.2% vs. 93.8±13.1%, p=0.040; FEV1 % predicted: 105.4±19.5% vs. 95.9±21.2%, p=0.002). In addition, the proportion of patients with a FEV1/FVC of <70%, was lower in the larger testes group. Univariate analysis conducted using linear regression models, revealed that testicular volume was correlated with FVC (r=0.162, p=0.029), FEV1 (r=0.218, p=0.003), FEV1/FVC (r=0.149, p=0.046), and FEV1 % predicted (r=0.178, p=0.017), and multivariate analysis using linear regression models, revealed that testicular volume was a significant predictive factor for FEV1 % predicted (ß=0.159, p=0.041). CONCLUSION: Larger testicular volume was independently associated, with favorable indices of lung function. These results suggest that androgens, may contribute to better lung function.

20.
Circulation ; 135(21): 2003-2012, 2017 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-28385948

RESUMO

BACKGROUND: The HeartMate 3 (HM3) Left Ventricular Assist System (LVAS) (Abbott) is a centrifugal, fully magnetically levitated, continuous-flow blood pump engineered to enhance hemocompatibility and reduce shear stress on blood components. The MOMENTUM 3 trial (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3) compares the HM3 LVAS with the HeartMate II (HMII) LVAS (Abbott) in advanced heart failure refractory to medical management, irrespective of therapeutic intention (bridge to transplant versus destination therapy). This investigation reported its primary outcome in the short-term cohort (n=294; 6-month follow-up), demonstrating superiority of the HM3 for the trial primary end point (survival free of a disabling stroke or reoperation to replace the pump for malfunction), driven by a reduced need for reoperations. The aim of this analysis was to evaluate the aggregate of hemocompatibility-related clinical adverse events (HRAEs) between the 2 LVAS. METHODS: We conducted a secondary end point evaluation of HRAE (survival free of any nonsurgical bleeding, thromboembolic event, pump thrombosis, or neurological event) in the short-term cohort (as-treated cohort n=289) at 6 months. The net burden of HRAE was also assessed by using a previously described hemocompatibility score, which uses 4 escalating tiers of hierarchal severity to derive a total score for events encountered during the entire follow-up experience for each patient. RESULTS: In 289 patients in the as-treated group (151 the HM3 and 138 the HMII), survival free of any HRAE was achieved in 69% of the HM3 group and in 55% of the HMII group (hazard ratio, 0.62; confidence interval, 0.42-0.91; P=0.012). Using the hemocompatibility score, the HM3 group demonstrated less pump thrombosis requiring reoperation (0 versus 36 points, P<0.001) or medically managed pump thrombosis (0 versus 5 points, P=0.02), and fewer nondisabling strokes (6 versus 24 points, P=0.026) than the control HMII LVAS. The net hemocompatibility score in the HM3 in comparison with the HMII patients was 101 (0.67±1.50 points/patient) versus 137 (0.99±1.79 points/patient) (odds ratio, 0.64; confidence interval, 0.39-1.03; P=0.065). CONCLUSIONS: In this secondary analysis of the MOMENTUM 3 trial, the HM3 LVAS demonstrated greater freedom from HRAEs in comparison with the HMII LVAS at 6 months. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov. Unique identifier: NCT02224755.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Imãs , Função Ventricular Esquerda , Idoso , Remoção de Dispositivo , Intervalo Livre de Doença , Desenho de Equipamento , Falha de Equipamento , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar/efeitos adversos , Hemólise , Humanos , Estimativa de Kaplan-Meier , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Razão de Chances , Modelos de Riscos Proporcionais , Estudos Prospectivos , Fatores de Risco , Estresse Mecânico , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA