Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1515: 146-153, 2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-28803649

RESUMO

In protein chromatography, process variations, such as aging of column or process errors, can result in deviations of the product and impurity levels. Consequently, the process performance described by purity, yield, or production rate may decrease. Based on visual inspection of the UV signal, it is hard to identify the source of the error and almost unfeasible to determine the quantity of deviation. The problem becomes even more pronounced, if multiple root causes of the deviation are interconnected and lead to an observable deviation. In the presented work, a novel method based on the combination of mechanistic chromatography models and the artificial neural networks is suggested to solve this problem. In a case study using a model protein mixture, the determination of deviations in column capacity and elution gradient length was shown. Maximal errors of 1.5% and 4.90% for the prediction of deviation in column capacity and elution gradient length respectively demonstrated the capability of this method for root cause investigation.


Assuntos
Cromatografia Líquida/métodos , Redes Neurais de Computação , Proteínas/isolamento & purificação , Cromatografia Líquida/instrumentação , Modelos Teóricos , Proteínas/química
2.
J Chromatogr A ; 1437: 158-167, 2016 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-26879457

RESUMO

In chromatographic protein purification, process variations, aging of columns, or processing errors can lead to deviations of the expected elution behavior of product and contaminants and can result in a decreased pool purity or yield. A different elution behavior of all or several involved species leads to a deviating chromatogram. The causes for deviations are however hard to identify by visual inspection and complicate the correction of a problem in the next cycle or batch. To overcome this issue, a tool for root cause investigation in protein chromatography was developed. The tool combines a spectral deconvolution with inverse mechanistic modelling. Mid-UV spectral data and Partial Least Squares Regression were first applied to deconvolute peaks to obtain the individual elution profiles of co-eluting proteins. The individual elution profiles were subsequently used to identify errors in process parameters by curve fitting to a mechanistic chromatography model. The functionality of the tool for root cause investigation was successfully demonstrated in a model protein study with lysozyme, cytochrome c, and ribonuclease A. Deviating chromatograms were generated by deliberately caused errors in the process parameters flow rate and sodium-ion concentration in loading and elution buffer according to a design of experiments. The actual values of the three process parameters and, thus, the causes of the deviations were estimated with errors of less than 4.4%. Consequently, the established tool for root cause investigation is a valuable approach to rapidly identify process variations, aging of columns, or processing errors. This might help to minimize batch rejections or contribute to an increased productivity.


Assuntos
Cromatografia/métodos , Cromatografia/normas , Modelos Químicos , Proteínas/química , Projetos de Pesquisa , Análise dos Mínimos Quadrados , Proteínas/análise , Proteínas/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA