1.
ISA Trans ; 138: 603-610, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36841720

RESUMO

Scanning acoustic microscopy (SAM) technique has been applied to defect inspection in electronic devices. With the increase of packaging density, detection of the micro-defects in high density devices becomes more and more challenging. The SAM test is suffering from sacrificing the spatial resolution to reach a certain penetration depth of the ultrasonic waves. So it is necessary to enhance the resolution level of the SAM image. In this paper, a wavelet based resolution enhancement technique was investigated to reconstruct a high quality image for SAM test of the flip chip packages. The stationary wavelet transform was adopted to decompose the captured SAM image into four frequency subbands, and the high frequency subbands were enhanced by adding the difference matrix in the intermediate stage, and a super resolution SAM image was derived from combining all the subbands by using the Inverse Discrete Wavelet Transform. Then the solder joints segmented from the SR-SAM image were classified by using the SVM algorithm. The results validated that the proposed technique is effective to improve the detection accuracy of SAM test.