RESUMO
Background: This study aims at evaluating the validity profile of Titmus vision screener V4 for gauging visual acuity and colour perception as a screening tool. Methods: Eleven hundred young adults attending eye OPD at a tertiary care center were included in the study. All individuals underwent distance visual acuity (DVA) measurement with Snellen chart and Titmus vision screener V4, at 6 m on the same day. Later, these individuals underwent colour vision testing with Ishihara pseudo isochromatic plates and Titmus vision screener V4. Results: The age distribution ranged from 19 to 53 years with mean age as 26.6 years. Males (87.4%) were more as compared to females. Mean DVA measured by Snellen's chart and Titmus vision screener V4 were 0.088 ± 0.15 and 0.110 ± 0.17, respectively (p = 0.000). Mean difference between DVA by Snellen's chart and Titmus screener V4 was -0.021 ± 0.82 with 95% CI (-0.026 to -0.016). For measuring visual acuity, Titmus vision screener V4 showed a sensitivity of 99.5% and specificity of 90.6%. Negative predictive value and positive predictive value were 99.6% and 85.6%, respectively. For diagnosing colour perception, the Titmus vision screener V4 showed a sensitivity of 100% and specificity of 99.8%. The negative predictive value and positive predictive value were 100% and 88.8% respectively. Area under the curve of receiver operating characteristic (ROC) curve was 0.960 with 95%CI (0.949-0.972). Conclusion: Our study supports use of Titmus vision screener V4 as an excellent screening tool for measurement of visual acuity as well as colour perception.
RESUMO
This study aimed to discover distance visual acuity (VA) assessments through the display of the Snellen chart on the iPad tablet. The findings are equivalent to those obtained using the conventional light-box Snellen chart. In this work, the Snellen iPad app and Eye Chart HD iOS app are utilized among the participants in the Ophthalmology Outpatient Department (OPD) for determining VA. A cross-sectional method was used for the examination, which included 100 new patients who were chosen by random selection. The age requirement for new patients was 8 years and up for both genders. Patients with a VA of less than 6/30 were disqualified from the experiment. Two testing modalities are used to measure VA, such as the iPad Mini 2 with the iOS software Eye Chart HD and the classic Snellen light-box chart. The observation revealed that the Snellen iPad app and the classic light-box Snellen chart produced equivalent findings. The classic Snellen chart may have been memorized by participants before their eye examination, undermining the accuracy of the conclusions of the initial testing modality used. Patient-related variables were also identified as confounders. Future studies should adjust the brightness of the iPad Mini 2 and the traditional light-box Snellen chart to make sure that neither experiment modality's brightness affects the accuracy of the findings. Future research should also investigate the use of premium apps, use both devices, and employ a bigger sample size.
RESUMO
AIM: To investigate the efficacy of a new visual acuity (VA) screening method, the baby vision test for young children. METHODS: A total 105 eyes of 65 children aged 2-8y were included in the study. Acuity testing was conducted using a standardized recognition acuity chart (Snellen visual chart: at 3 m) and the baby vision model assessment. The baby vision device includes a screen, a near infrared camera and a computer. Children were seated at a measured distance of 33-40 cm from a display for testing. VA was estimated according to the highest resolution the children could follow. Decimal VA data were converted to logarithm of the minimum angle of resolution (logMAR) for statistical analysis. The VA results for each child were recorded and analyzed for consistency. RESULTS: The mean VA measured using the Snellen visual chart was 0.62±0.32, and that assessed using the baby vision test was 0.66±0.27. The 95% limit of agreement was -0.609 to 0.695, with 95.2% (100/105) plots within the 95% limits of agreement. VA values of the baby vision test were significantly correlated with those of the Snellen chart (R=0.274, P=0.005). CONCLUSION: The baby vision test can be used as a relatively reliable method for estimating VA in young children. This new acuity assessment might be a valid predictor of optotype-measured acuity later in preverbal children.
RESUMO
Visual acuity is one of the most important parameters for evaluating the vision of patients with keratoconus. This study reviewed 295 articles related to keratoconus published between 2017 and 2022 in which visual acuity was one of the parameters measured. The methodology of visual acuity testing in studies on keratoconus was thoroughly analyzed. The analysis showed that the most commonly indicated chart for testing visual acuity papers on keratoconus is the Snellen chart. It was shown that in 150 out of 295 articles, the authors do not describe the methodology for testing visual acuity. What is more, it was also shown that in 68 of the 295 articles which were analyzed, a procedure for converting visual acuity tested with a Snellen chart into a logMAR scale was used. In this review, we discuss the validity and reliability of such conversions. In particular, we show that insufficient description of visual acuity testing methodology and lack of information on the conversion of visual acuity results into the logMAR scale may contribute to the misinterpretation of visual acuity test results.
RESUMO
Objectives: The primary objective of this study was to evaluate the agreement of visual acuity (VA) obtained with the sweep visual evoked potential (sVEP) method with the VA obtained with the Snellen chart. The secondary objective was to examine the effect of age and gender on agreement. Materials and Methods: Best corrected VAs of subjects were recorded with the Snellen chart, and sVEP testing was performed according to the recommendations of the International Society for Clinical Electrophysiology of Vision (ISCEV). Snellen VAs and sVEP measurements were analyzed using logMAR conversion for statistical analysis. Agreement was evaluated with Bland-Altman analysis. Results: The study included 49 subjects with a mean age of 53.5±17.3 years (range: 19-75 years) and mean Snellen VA of 0.31±0.32 logMAR (range: 1.3-0.0 logMAR). In the Bland-Altman analysis, the mean differences between the VA and sVEP measurements (VA-sVEP) were significantly different and outside the limits of agreement (p=0.035). A significant proportional bias (p=0.0007) was found in the regression analysis performed between VA-sVEP and the mean VA. According to the Bland-Altman analysis of sex subgroups, there was a significant difference between VA and sVEP measurements in female subjects (p=0.006). The difference between VA and sVEP measurement increased significantly with older age (R2: 0.306, p<0.001, ß: 0.05 [0.03, 0.08]). Conclusion: In conclusion, sVEP measurements and VAs did not show statistical agreement. Cranial anatomy and endocrine differences of the subjects may affect their sVEP measurements. The difference between the methods varies according to VA level. Directly using sVEP results instead of VA would not be appropriate.
Assuntos
Potenciais Evocados Visuais , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Acuidade VisualRESUMO
PURPOSE: Evaluate the differences between clinical visual acuity (VA) as recorded in medical records and electronic Early Treatment Diabetic Retinopathy Study (eETDRS) protocol VA measurements and factors affecting the size of the differences. DESIGN: Retrospective chart review. PARTICIPANTS: Study and fellow eyes of participants enrolled in DRCR Retina Network Protocols AC and AE (diabetic macular edema), and W (nonproliferative diabetic retinopathy) with clinical VA recorded within 3 months before the protocol visit. METHODS: Differences and their association with patient and ocular factors were evaluated using linear mixed models with random effects for correlations within sites and participants. MAIN OUTCOME MEASURE: Difference between VA letter scores measured by eETDRS during a study visit versus measured by Snellen during a regular clinical visit (Snellen fraction converted to eETDRS). RESULTS: Data from 1016 eyes (511 participants) across 74 sites were analyzed. The mean VA measurements were 68.6 letters (Snellen equivalent 20/50) at the clinical visit and 76.3 letters (Snellen equivalent 20/32) at the protocol visit, with a mean (standard deviation [SD]) of 26 (21) days between visits. Mean (SD) protocol VA was better than clinical VA by 7.6 (9.6) letters overall, 10.7 (12.6) letters in eyes with clinical VA ≤ 20/50 (n = 376), and 5.8 (6.6) letters in eyes with clinical VA ≥ 20/40 (n = 640). On average, the difference between clinical and protocol VA was 1.3 letters smaller for every 1-line (5 letters) increase in clinical VA (P < 0.001). Mean (SD) differences by clinical correction of refractive error were 3.9 (9.0) letters with refraction, 6.9 (9.2) letters with glasses/contact lenses, 7.9 (11.5) letters with pinhole, and 9.8 (9.3) letters without correction (P = 0.06). CONCLUSIONS: On average, clinical Snellen VA is 1 to 2 lines worse than eETDRS protocol refraction and VA testing, which may partly explain why clinical practice does not always replicate clinical trial results. Eyes with lower clinical measurements and eyes tested without clinical refraction tended to have larger differences. Considering the potential discrepancies between clinical and protocol VA measurements, refracting eyes in the clinic may benefit patients when determining treatment plans and study referrals based on vision. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.
Assuntos
Retinopatia Diabética , Edema Macular , Humanos , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/tratamento farmacológico , Edema Macular/diagnóstico , Edema Macular/tratamento farmacológico , Estudos Retrospectivos , Acuidade Visual , Retina , Inibidores da Angiogênese/uso terapêutico , Injeções IntravítreasRESUMO
This study was designed to explore practical differences between visual acuity (VA) scores measured on Snellen chart versus ETDRS chart, to grade cataracts using LOCS III system, and to compare VA on both charts depending on cataract grade and type. Prospective evaluation of uncorrected and best-corrected visual acuity was carried out on the eye scheduled for cataract surgery preoperatively and postoperatively on the Snellen and ETDRS charts. The study was carried out at Department of Eye Diseases, Clinical Center of Serbia, during a two-year period. Inclusion criteria were met by 540 patients who underwent testing, surgery, data collection and analysis. The mean VA score was better on ETDRS than on Snellen chart. The mean difference was 6.05 letters or 1.21 lines. VA results correlated with all types of cataract regardless of the chart used, with the highest statistical significance (p<0.0001) for subcapsular cataract. The ETDRS chart was found to be more discriminative and precise than Snellen chart, especially for poor VA.
Assuntos
Catarata , Testes Visuais , Catarata/complicações , Humanos , Exame Neurológico , Transtornos da Visão , Testes Visuais/métodos , Acuidade VisualRESUMO
Visual acuity plays an important role in dentists' vision in their daily clinical routine. This study aimed to determine dental students' visual acuity without optical aids and when using magnification devices in simulated clinical conditions. The participants were forty-six students at the School of Dental Medicine with a visual acuity of 1.0 in decimal values or 100% in percentage. The central visual acuity was tested using a miniature Snellen eye chart placed in the molar cavity of a dental phantom, in simulated clinical conditions under five different settings (natural visual acuity, by applying head magnifying glasses x1,5 and binocular magnifying devices using Galileo's x2,5/350 mm, Keplerx3,3/450 mm and Keplerx4,5/350 mm optical system). The Wilcoxon Signed Rank test shows that the distribution of measurements of the visual acuity undertaken by the application of magnifying devices (VNL, VGA2,5, VKP3,3, VKP4,5) contained higher values of visual acuity than those received by the use of natural vision (VSC) (p < 0.001 for the comparison to the VNL, VGA2,5, VKP3,3 and VKP4,5 groups). The highest and statistically most significant increase in visual acuity is achieved using the Keplerian telescope x4.5/350 mm. The application of magnifying devices provided dentistry professionals with better visual acuity, improving detail detection in an oral cavity during dental procedures by magnifying the oral structure. The use of magnification devices means much more precise work, decreases the operating time, improves posture and reduces muscle pain in the shoulder during dental treatment.
RESUMO
Background: Smartphone applications (apps) are increasingly becoming more popular for medical use. Aim: The aim of this article is to determine the willingness and ease of using smartphone apps for visual assessment among adult patients attending the general outpatient ophthalmology clinic of Ahmadu Bello University Teaching Hospital, Zaria in Nigeria. Design: The study was a hospital-based descriptive cross-sectional design. Materials and Methods: New and old adult patients who presented at the clinic and consented to the study were selected. Visual acuity assessment was done using a 6-m Snellen chart and three selected Smartphone visual acuity applications sequentially. A semi-structured questionnaire was used for data collection and then analysed using SPSS version 23. Results: A total of 287 patients were studied. Majority (96%) of the patients found the Smartphone apps to be easy to use. A good proportion (76%) of the patients also believed that Smartphone charts were easier to use than the conventional Snellen chart and expressed willingness to use the app again. Conclusion: Smartphone visual acuity apps could offer a convenient, easy-to-learn, and easy-to-use means of visual acuity assessment. This coupled with the demonstrated patient's willingness to embrace this technology could be used to encourage the use of clinically validated apps for the early detection as well as monitoring of any impairment of vision, especially in out-of-clinic situations.
RESUMO
Recently, three international norms (ISO) for visual acuity assessment were revised. The DIN EN ISO 8596:2018 stipulates the Landolt C eye chart as the standard optotype and specifies display characteristics. An informative annex lists clinical optotypes for the first time. These include the ETDRS chart, Snellen chart and pediatric optotypes; however, these clinical optotypes do not have the same status as the Landolt C chart, since even with identical font size and stroke width they may differ in recognizability. The technical report ISO/TR 19498:2015 complements DIN EN ISO 8596. A scientifically appropriate procedure is described, which enables a quantitative correlation of clinical optotypes with the Landolt C chart. The DIN EN ISO 10938:2016 describes the required optical quality of optotypes. For the first time, electronic devices are explicitly approved for standardized visual acuity tests. Consequently, according to this amendment electronic devices may be used for acuity assessment for ophthalmological expert opinions according to DIN 58220, part 3.
Assuntos
Oftalmologia , Acuidade Visual , Criança , Humanos , Testes VisuaisRESUMO
Diaphania angustalis Snellen (Lepidoptera: Crambidae) is the main defoliator of Alstonia schalaris. In this article, observation of external morphological and ultrastructure structure of adult antennae of D. angustalis was carried out using the scanning and transmission electron microscope. The results showed that both male and female antennae were filiform and could be divided into scape, pedicel, and flagellum. There are eight types and two subtypes of antennal sensilla, namely, sensilla trichodea, sensilla chaetica (I & II), sensilla coeloconica, sensilla auricillica, sensilla styloconica, sensilla squamiformia, capitate peg, and Böhm bristles. Most sensilla are concentrated in venter and the sides of antennae. Analyses on morphological and quantitative differences of antennal sensilla between male and female adults. The size of SCo is significantly different between male and female. In terms of quantity, only SSt and CP have no significant differences between male and female. By comparing the existing antennal sensilla of Crambidae, it is found that STr, SCh, SCo, and SAu are common sensilla. These results can contribute to further research on the function of sensilla of D. angustalis relating to its behavior. A detailed description is provided of the antennal sensilla in Diaphania angustalis. Diaphania angustalis has the rare sensilla of capitate peg in Crambidae. No sexual dimorphism of sensillum types is found in the species. The number and distribution of sensilla trichodea, sensilla chaetica, sensilla coeloconica, and sensilla auricillica sensillum are different.
Assuntos
Antenas de Artrópodes/anatomia & histologia , Lepidópteros/ultraestrutura , Sensilas/ultraestrutura , Animais , Biometria , Transmissão de Doença Infecciosa , Feminino , Masculino , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de TransmissãoRESUMO
Aim: To compare visual acuity using the LEA symbol chart with Snellen E test chart in preschool children of age 3-5 years. Patients and methods: Inclusion criteria: 50 emmetropic children aged 3 to 5 years. Exclusion criteria: Strabismus, amblyopia, ametropia, and any organic eye disease. A pseudo randomized protocol was used to test visual acuity (VA) in each subject monocularly on both eyes using Snellen E chart and LEA symbol chart. Visual acuity for both charts was scored as smallest optotype size which the child correctly identified 3 of maximum 4 optotypes. The strength of agreement on VA between two charts was tested using Interclass correlation coefficient (ICC). A Mann-Whitney U test was applied to compare both the groups. Results: Boys: Girls = 26:24 with a mean age and standard deviation of 4.12 + 0.79 years. ICC between Snellen's and LEA symbol chart was 0.256 and 0.213 for right and left eye respectively. Analysis of the two samples using Mann-Whitney test showed a significant difference between the two charts (p value <0.000). Conclusion: LEA symbol test showed only a fair agreement with Snellen E charts for visual acuity measurements. Visual acuity measurement with LEA symbol chart showed significantly higher scores as compared to Snellen's chart.
Assuntos
Ambliopia/diagnóstico , Erros de Refração/diagnóstico , Estrabismo/diagnóstico , Seleção Visual/instrumentação , Acuidade Visual , Ambliopia/fisiopatologia , Pré-Escolar , Feminino , Humanos , Masculino , Erros de Refração/fisiopatologia , Reprodutibilidade dos Testes , Estrabismo/fisiopatologia , Visão Binocular/fisiologiaRESUMO
Purpose: To compare four visual acuity (VA) scoring termination rules. Methods: A computer simulation generated 30,000 virtual patients who underwent 10 repetitions for each of four termination rules, on both the Snellen and ETDRS charts (2.4 million tests performed in total). Three termination rules focused on the smallest character row: all characters were correctly identified (100%), one character was incorrectly identified (one miss) and 50% or more of the characters were correctly identified (50%). The forth termination rule used a calculation in which each character, when correctly recognized, contributed a proportional increment (per-letter). Accuracy, test-retest variability (TRV) and test duration were measured. Next, a clinical study was conducted in which 254 subjects underwent three repetitions of the ETDRS VA test from 4 m, and VA scores for each of the four scoring termination rules were calculated. Results: In the Snellen simulation, the mean accuracy of the 100%, one miss, 50% and per-letter termination rules in decimal was 0.23 (-0.16 logMAR), 0.11 (-0.09 logMAR), 0.10 (-0.08 logMAR), and -0.08 (0.08 logMAR) respectively; while with the ETDRS simulation, the mean accuracy in decimal was 0.34 (-0.22 logMAR), 0.14 (-0.11 logMAR), 0.07 (-0.06 logMAR), and 0.07 (-0.05 logMAR), respectively. For the ETDRS simulation, the per-letter had the lowest TRV values and the longest test duration. In the clinical study (n = 254), the reproducibility of the 100%, one miss, 50% and per-letter was 0.50, 0.53, 0.17, 0.14, respectively. Conclusions: Clinical study and simulation data both suggest that the 100% and one-miss termination rules have higher TRVs, while the 50% and per-letter demonstrated much tighter, and rather close, TRV values.
Assuntos
Simulação por Computador , Testes Visuais , Acuidade Visual/fisiologia , Adulto , Algoritmos , Reações Falso-Positivas , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos TestesRESUMO
The article reviews the evolution of visual acuity assessment and gives comparison of the visual acuity charts (Snellen vs. ETDRS) widely used in research and clinical practice.
Assuntos
Testes Visuais , Acuidade Visual , Reprodutibilidade dos TestesRESUMO
Resumo Objetivo: Avaliar o perfil epidemiologico de disfuncao da acuidade visual (AV), possiveis disturbios oculares e a frequencia ao atendimento oftalmologico, de escolares do municipio de Itauna, Minas Gerais, Brasil. Posteriormente objetivou-se o encaminhamento ao especialista para correcao das anormalidades. Métodos: Estudo transversal, com populacao avaliada de 432 alunos da rede publica de ensino. Os individuos foram avaliados pelo metodo Snellen e a faixa etaria da amostra variou de 4 a 17 anos. Os dados foram colhidos e sistematizados. Foram encaminhados para o servico de Oftalmologia aqueles que possuiam AV ≤ 0,7 em pelo menos um dos olhos. Resultados: Dos 432 alunos avaliados neste estudo 14,5% apresentaram baixa AV, quando avaliados pelo teste de Snellen. Destes, 61,9 % pertenciam ao sexo feminino. A faixa etaria em que houve maior prevalencia de baixa visao foram escolares de 15 a 17 anos. A maioria apresentou alteracao em ambos os olhos e 60% dos alunos avaliados declararam nunca terem passado por uma consulta oftalmologica. Dos alunos que compareceram as consultas, a maioria foi diagnosticada com erros de refracao e necessitou de correcao otica. Conclusão: Os resultados encontrados demonstram que a parcela significativa dos individuos avaliados apresentou baixa visao e necessitou de encaminhamento oftalmologico. Alem disso, observou-se a inexistencia de consultas oftalmológicas anteriores em grande parte dos escolares. Esse fato reforca, diante dos orgaos publicos de saude, a necessidade de implantar sistemas de triagem visual nas escolas e oferecer assistencia a esses estudantes, objetivando melhorias em seu aprendizado e qualidade de vida.
ABSTRACT Objective: To evaluate the epidemiological profile of visual acuity (VA) dysfunction, the possible ocular disorders and the frequency of ophthalmologic care of school children from the city of Itaúna, Minas Gerais, Brazil. Methods: A cross-sectional study with a population of 432 students in the public schools. The individuals were evaluated by the Snellen method and the sample age ranged from 4 to 17 years. Data were collected and systematized. Those who had VA ≤ 0.7 in at least one eye were referred to the ophthalmology service. Results: Of the 432 students evaluated in this study, 14.5% presented low VA, when evaluated by the Snellen test. Of these, 61.9% were female. The age group with the highest prevalence of low vision were schoolchildren aged 15 to 17 years. The majority presented alteration in both eyes and 60% of the evaluated students stated that they had never had an ophthalmological consultation. Of the students who attended the consultations, most were diagnosed with refractive errors and needed optical correction. Conclusion: The results showed that a significant portion of the individuals evaluated had low vision and required ophthalmologic referral. In addition, there was no previous ophthalmological consultation in most of the schoolchildren. This fact reinforces to public health agencies, the need to implement visual screening systems in schools and offer assistance to these students, with the aim of improvements in their learning and quality of life
Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adolescente , Erros de Refração/diagnóstico , Transtornos da Visão/diagnóstico , Acuidade Visual , Seleção Visual , Instituições Acadêmicas , Estudantes , Testes Visuais , Prevalência , Estudos TransversaisRESUMO
Objetivos: Neste estudo foi realizada uma triagem oftalmológica em crianças matriculadas em duas escolas (1ª a 4ª série) da rede pública de ensino no município de Alfenas MG (Brasil), posteriormente relacionando a baixa acuidade visual (AV) com fatores de risco. Metodologia: Este é um estudo transversal no qual a AV foi avaliada por meio do teste de Snellen e questionários foram respondidos pelos pais e professores das crianças que apresentaram alterações da AV. Resultados: Foram avaliadas 764 crianças (n = 764, 52% do sexo feminino; IC(95%) 48-55%) de 6 a 10 anos de idade, tendo sido observado que 97 delas (13%; IC(95%) 10-15%) apresentaram alguma alteração na AV e, dentre as 97, 53% (IC(95%) 43-63%) foram do sexo masculino. Não houve relação entre a prevalência de baixa AV e sexo da criança (χ² com p>0,05). O teste exato de Fisher revelou que a alta percentagem de crianças que nunca realizaram um exame oftalmológico teve uma significativa relação com a baixa AV (p<0,0001). 30% das crianças alegaram aos pais "enxergar bem" (autopercepção da visão), apesar de apresentarem baixa AV, indicando que a simples falta do parâmetro de comparação para a percepção de problemas na AV torna as triagens oftalmológicas essenciais nesta faixa etária. Em entrevista com professores, foi verificado haver uma infra-estrutura inadequada no sistema educacional e dificuldades para satisfazer as necessidades básicas educacionais de crianças com problemas visuais, bem como para identificar alterações na AV dos alunos e propiciar promoção de saúde no espaço escolar. Conclusão: Neste estudo a prevalência de baixa AV foi 13%, assim, é destacada a importância de uma triagem oftalmológica em crianças em idade pré-escolar e escolar visando o diagnóstico precoce dos problemas de visão e posterior esclarecimento e tratamento, possibilitando os desenvolvimentos social e cognitivo normais dos estudantes.
Aims: In this study, an ophthalmologic screening was performed in children attending two public schools (from 1st to 4th grade) in Alfenas city/MG (Brazil), and later correlated low visual acuity (VA) with risk factors. Methodology: This is a cross-sectional study, in which the VA was evaluated through the Snellen test and the parents and teachers of the children who presented alterations then answered questionnaires. Results: A total of 764 children (n = 764, 52.0% were females; CI(95%) 48.0-55.0%) from 6 to 10 years of age were evaluated, with 97 (13.0%; CI(95%) 10.0-15.0%) suffering impairment in the VA; of these, 53.0% (CI(95%) 43.0-63.0%) were males. The prevalence of low VA in male and female children was statistically the same (χ² with p>0.05). The Fisher test evidenced that the higher percentage of children who had never ever performed an ophthalmologic examination had a significant relation with low VA (p<0.0001). To 30% parents' awareness, the children claimed "see well" (despite they present low VA, as detected here), indicating that the simple lack of a comparison parameter for the perception of visual impairments makes ophthalmologic screening essential in this age group. In an interview with teachers, the respondents reported an inadequate infrastructure in the educational system and difficulties to satisfy the basic educational needs of children with sight problems, as well as to identify alterations in the VA of them, and to afford health promotion at schools. Conclusion: We reported that the prevalence of low VA was 13% accordingly is highlighted the importance of ophthalmologic screening of school-age children is highlighted, aiming at the early detection of eye problems in childhood and subsequent clarification and treatment, making possible a normal social and cognitive development of the students.
RESUMO
Gene therapy in ophthalmology has developed rapidly, and there has been a breakthrough in the treatment of Leber's hereditary optic neuropathy. After receiving an intravitreal injection of rAAV2-ND4, patients followed up over a certain time period showed a definite increase in visual acuity. Visual acuity testing is critical for assessing the efficacy of rAAV2-ND4 intravitreal injection.
Assuntos
Dependovirus/genética , Terapia Genética/métodos , Injeções Intravítreas/métodos , NADH Desidrogenase/genética , Atrofia Óptica Hereditária de Leber/terapia , Acuidade Visual , Humanos , Atrofia Óptica Hereditária de Leber/genética , Visão Ocular/fisiologiaRESUMO
PURPOSE: The aim of this study was to compare three different methods to measure visual acuity (VA) in healthy and amblyopic preschool children: a Snellen E chart (SE), a single Lea symbols (SLS), and a crowded Lea symbols (CLS). METHODS: Seventy-eight eyes of 54 patients (28 females, 26 males) were included in this cross-sectional, comparative study. The control group consisted of 30 healthy cases, and the amblyopic group consisted of 24 patients with amblyopia. Best-corrected VA (BCVA) measurements with SLS, CLS, and SE were compared in control eyes (CE), amblyopic eyes (AE), and fellow eyes (FE) separately. RESULTS: The mean age of the cohort was 5.7 ± 0.7 years (range 5-7 years). The mean refractive error was +1.02 ± 0.36 D (diopter, spherical equivalent) in CE, +5.59 ± 2.45 D in AE, and +3.96 ± 2.38 D in FE. The median BCVA (logMAR) was (in order of SLS, CLS, and SE) 0.00 [interquartile range (IQR) 0.10], 0.10 (IQR 0.10), 0.00 (IQR 0.10) in CE, 0.25 (IQR 0.33), 0.35 (IQR 0.30), 0.25 (IQR 0.38) in AE, and 0.10 (IQR 0.08), 0.10 (IQR 0.00), 0.10 (IQR 0.10) in FE. There was no statistically significant difference between the three methods in terms of the CE or FE (p > 0.05). In contrast, there was a statistically significant difference in AE (p < 0.05). The mean VA measurement with SLS was higher compared with CLS in AE. A positive and strong correlation between the three charts was found in all of the groups (p < 0.001). CONCLUSION: We found SLS, CLS, and SE to be consistent: all three methods can be used to obtain measurements of VA in healthy and amblyopic preschool children.
Assuntos
Ambliopia/fisiopatologia , Refração Ocular/fisiologia , Erros de Refração/fisiopatologia , Testes Visuais/métodos , Acuidade Visual , Ambliopia/diagnóstico , Criança , Pré-Escolar , Estudos Transversais , Feminino , Seguimentos , Humanos , Masculino , Erros de Refração/diagnóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de TempoRESUMO
In this paper, the authors describe an online tool with which to convert and thus quantify count finger measurements of visual acuity into Snellen equivalents. It is hoped that this tool allows for the re-interpretation of retrospectively collected data that provide visual acuity in terms of qualitative count finger measurements.
RESUMO
AIM: To compare accuracy, reproducibility and test duration for the Snellen and the Early Treatment Diabetic Retinopathy Study (ETDRS) charts, two main tools used to measure visual acuity (VA). METHODS: A computer simulation was programmed to run multiple virtual patients, each with a unique set of assigned parameters, including VA, false-positive and false-negative error values. For each virtual patient, assigned VA was randomly chosen along a continuous scale spanning the range between 1.0 to 0.0 logMAR units (equivalent to 20/200 to 20/20). Each of 30 000 virtual patients were run ten times on each of the two VA charts. RESULTS: Average test duration (expressed as the total number of characters presented during the test ±SD) was 12.6±11.1 and 31.2±14.7 characters, for the Snellen and ETDRS, respectively. Accuracy, defined as the absolute difference (± SD) between the assigned VA and the measured VA, expressed in logMAR units, was superior in the ETDRS charts: 0.12±0.14 and 0.08±0.08, for the Snellen and ETDRS charts, respectively. Reproducibility, expressed as test-retest variability, was superior in the ETDRS charts: 0.23±0.17 and 0.11±0.09 logMAR units, for the Snellen and ETDRS charts, respectively. CONCLUSION: A comparison of true (assigned) VA to measured VA, demonstrated, on average, better accuracy and reproducibility of the ETDRS chart, but at the penalty of significantly longer test duration. These differences were most pronounced in the low VA range. The reproducibility using a simulation approach is in line with reproducibility values found in several clinical studies.