OBJECTIVE: This study aimed at investigating the effect of median nerve stimulation on ipsilateral cortical potentials evoked by contralateral median nerve electrical stimulation. METHODS: We recorded somatosensory-evoked potentials (SEPs) from the left parietal cortex in 15 right-handed, healthy subjects. We administered bilateral median nerve stimulation, with the ipsilateral stimulation preceding the stimulation on the contralateral by intervals of 5, 10, 20, or 40 ms. We adjusted these intervals based on each individual's N20 latency. As a measure of S1 excitability, the amplitude of the N20 and the area of the High Frequency Oscillation (HFO) burst were analyzed for each condition. RESULTS: The results revealed significant inhibition of N20 amplitude by ipsilateral median nerve stimulation at interstimulus intervals (ISIs) between 5 and 40 ms. Late HFO burst was suppressed at short ISIs of 5 and 10 ms, pointing to a transcallosal inhibitory effect on S1 intracortical circuits. CONCLUSIONS: Findings suggest interhemispheric interaction between the primary somatosensory areas, supporting the existence of transcallosal transfer of tactile information. SIGNIFICANCE: This study provides valuable insights into the interhemispheric connections between primary sensory areas and underscore the potential role of interhemispheric interactions in somatosensory processing.

2.
Neurodiagn J ; : 1-16, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38941588

RESUMO

Intraoperative neurophysiological monitoring (IONM) is shown to be useful in surgeries when the nervous system is at risk. Its success in part relies upon proper setup of often dozens of electrodes correctly placed and secured upon patients and inserted in specific stimulating and recording receptacles. Given the complicated setups and the demanding operating room environment, errors in setup are bound to occur. These have led to false negatives associated with new patient morbidities including, at times, paralysis. No studies quantify the prevalence of these types of setup errors. Approximately 800,000 operations annually utilize intraoperative neuromonitoring in the US alone, so even a small percentage of errors suggests clinical significance. In addition, these types of errors hinder the overall effectiveness of IONM and may result in lower reported sensitivities and lower cost-effectiveness of this important service. We sought to discover through a prospective study and verification through chart review the prevalence of "electrode-swap" errors (when recording and/or stimulating electrodes are incorrectly placed on the patient or in the IONM equipment during setup) across all procedures monitored. We found recording and/or stimulating electrode set up errors in 24 of 454 cases (5.3%). These data and examples of how errors were discovered intraoperatively are reported. We also offer techniques to help reduce this error rate. This study demonstrates a significant potential avoidable error in IONM diagnostic utility, patient outcome, and sensitivity/specificity of alert criteria. The value of identifying and correcting these errors is consequential, multifaceted, and far-reaching.

3.
Children (Basel) ; 11(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38929255

RESUMO

BACKGROUND AND AIM: First, to compare somatosensory evoked potentials (SEPs) in preterm newborns without major brain injury studied at term equivalent age (TEA) with a term historical control group. Second, to investigate the impact of pain exposure during the first 28 days after birth on SEPs. Third, to evaluate the association between SEPs and Bayley-III at 2 years corrected age (CA). METHODS: Infants born at <32 weeks' gestational age (GA) were studied with continuous-SEPs. First, SEP differences between preterm and term infants were analyzed. Second, regression analyses were conducted to explore the association between SEPs and painful procedures, and then between SEPs and neurodevelopment. RESULTS: 86 preterm infants were prospectively enrolled. Preterm infants exhibited prolonged N1 latencies, central conduction times (CCTs), lower N1-P1 amplitudes, and more recurrently abnormal SEPs compared to term infants. Higher pain exposure predicted longer N1 latency and slower CCT (all p < 0.005), adjusting for clinical risk factors. Younger GA and postmenstrual age (PMA) at SEP recording were associated with longer N1 latency and lower N1-P1 amplitude (all p < 0.005). A normal SEP at TEA positively predicted cognitive outcome at 2 years CA (p < 0.005). CONCLUSION: Pain exposure and prematurity were risk factors for altered SEP parameters at TEA. SEPs predicted cognitive outcome.

4.
Eur J Neurosci ; 60(1): 3772-3794, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38726801

RESUMO

Beside the well-documented involvement of secondary somatosensory area, the cortical network underlying late somatosensory evoked potentials (P60/N60 and P100/N100) is still unknown. Electroencephalogram and magnetoencephalogram source imaging were performed to further investigate the origin of the brain cortical areas involved in late somatosensory evoked potentials, using sensory inputs of different strengths and by testing the correlation between cortical sources. Simultaneous high-density electroencephalograms and magnetoencephalograms were performed in 19 participants, and electrical stimulation was applied to the median nerve (wrist level) at intensity between 1.5 and 9 times the perceptual threshold. Source imaging was undertaken to map the stimulus-induced brain cortical activity according to each individual brain magnetic resonance imaging, during three windows of analysis covering early and late somatosensory evoked potentials. Results for P60/N60 and P100/N100 were compared with those for P20/N20 (early response). According to literature, maximal activity during P20/N20 was found in central sulcus contralateral to stimulation site. During P60/N60 and P100/N100, activity was observed in contralateral primary sensorimotor area, secondary somatosensory area (on both hemispheres) and premotor and multisensory associative cortices. Late responses exhibited similar characteristics but different from P20/N20, and no significant correlation was found between early and late generated activities. Specific clusters of cortical activities were activated with specific input/output relationships underlying early and late somatosensory evoked potentials. Cortical networks, partly common to and distinct from early somatosensory responses, contribute to late responses, all participating in the complex somatosensory brain processing.


Assuntos
Eletroencefalografia , Potenciais Somatossensoriais Evocados , Magnetoencefalografia , Córtex Somatossensorial , Humanos , Potenciais Somatossensoriais Evocados/fisiologia , Magnetoencefalografia/métodos , Masculino , Feminino , Adulto , Eletroencefalografia/métodos , Córtex Somatossensorial/fisiologia , Córtex Somatossensorial/diagnóstico por imagem , Nervo Mediano/fisiologia , Adulto Jovem , Estimulação Elétrica/métodos , Mapeamento Encefálico/métodos , Imageamento por Ressonância Magnética/métodos
5.
Neuroscience ; 551: 143-152, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-38735429

RESUMO

Homeostatic plasticity is a mechanism that stabilizes cortical excitability within a physiological range. Most homeostatic plasticity protocols have primed and tested the homeostatic response of the primary motor cortex (M1). This study investigated if a homeostatic response could be recorded from the primary sensory cortex (S1) after inducing homeostatic plasticity in M1. In 31 healthy participants, homeostatic plasticity was induced over M1 with a priming and testing block of transcranial direct current stimulation (tDCS) in two different sessions (anodal and cathodal). S1 excitability was assessed by early (N20, P25) and middle-latency (N33-P45) somatosensory evoked potentials (SEP) extracted from 4 electrodes (CP5, CP3, P5, P3). Baseline and post-measures (post-priming, 0-min, 10-min, and 20-min after homeostatic induction) were taken. Anodal M1 homeostatic plasticity induction significantly facilitated the N20-P25, P45 peak, and N33-P45 early SEP components up to 20-min post-induction, without any indication of a homeostatic response (i.e., reduced SEP). Cathodal homeostatic induction did not induce any significant effect on early or middle latency SEPs. M1 homeostatic plasticity induction by anodal stimulation protocol to the primary motor cortex did not induce a homeostatic response in SEPs.


Assuntos
Potenciais Somatossensoriais Evocados , Homeostase , Córtex Motor , Plasticidade Neuronal , Córtex Somatossensorial , Estimulação Transcraniana por Corrente Contínua , Humanos , Plasticidade Neuronal/fisiologia , Potenciais Somatossensoriais Evocados/fisiologia , Estimulação Transcraniana por Corrente Contínua/métodos , Masculino , Feminino , Córtex Motor/fisiologia , Homeostase/fisiologia , Adulto , Adulto Jovem , Córtex Somatossensorial/fisiologia , Eletroencefalografia/métodos
6.
World Neurosurg ; 188: 170-176, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38789031

RESUMO

OBJECTIVE: Intraoperative mapping of the nervous system is used to identify "eloquent" cortical areas. In this technical report, we describe a novel way of mapping the somatosensory cortex so that injury to those critical pathways can be avoided. METHODS: An 8-year-old female with drug resistant epilepsy presented for resection of a right posterior parietal focal cortical dysplasia. Left median nerve stimulation was used to record somatosensory evoked potentials (SEPs) directly from the somatosensory cortex with a strip electrode. A handheld monopolar electrode was also used to record both the median and tibial SEP. Total intravenous anesthesia with propofol and remifentanil was used. RESULTS: SEP recordings were obtained from a 4-contact strip electrode placed across the central sulcus. A phase reversal was identified and the most likely post central gyrus was noted. With the strip electrode left in place, a monopolar handheld electrode was used to record the median nerve SEPs from different locations on the postcentral gyrus. The tibial nerve was also stimulated to record where the highest amplitude tibial nerve SEP was present. This map was used delineate functionally "eloquent" areas to avoid during surgery. During resection, the median nerve SEP was recorded from the strip electrode continuously. No significant change in the SEP was noted, and the patient awoke without any sensory deficits. CONCLUSIONS: Sensory mapping of the cortex is possible with a handheld monopolar electrode. This technique is easy to perform and can help reduce neurological morbidity.


Assuntos
Mapeamento Encefálico , Potenciais Somatossensoriais Evocados , Nervo Mediano , Córtex Somatossensorial , Humanos , Feminino , Córtex Somatossensorial/cirurgia , Potenciais Somatossensoriais Evocados/fisiologia , Criança , Mapeamento Encefálico/métodos , Nervo Mediano/cirurgia , Epilepsia Resistente a Medicamentos/cirurgia , Monitorização Neurofisiológica Intraoperatória/métodos , Nervo Tibial , Estimulação Elétrica/métodos
7.
J Integr Neurosci ; 23(5): 98, 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38812396

RESUMO

OBJECTIVES: In this study, we explored the effects of chiropractic spinal adjustments on resting-state electroencephalography (EEG) recordings and early somatosensory evoked potentials (SEPs) in Alzheimer's and Parkinson's disease. METHODS: In this randomized cross-over study, 14 adults with Alzheimer's disease (average age 67 ± 6 years, 2 females:12 males) and 14 adults with Parkinson's disease (average age 62 ± 11 years, 1 female:13 males) participated. The participants underwent chiropractic spinal adjustments and a control (sham) intervention in a randomized order, with a minimum of one week between each intervention. EEG was recorded before and after each intervention, both during rest and stimulation of the right median nerve. The power-spectra was calculated for resting-state EEG, and the amplitude of the N30 peak was assessed for the SEPs. The source localization was performed on the power-spectra of resting-state EEG and the N30 SEP peak. RESULTS: Chiropractic spinal adjustment significantly reduced the N30 peak in individuals with Alzheimer's by 15% (p = 0.027). While other outcomes did not reach significance, resting-state EEG showed an increase in absolute power in all frequency bands after chiropractic spinal adjustments in individuals with Alzheimer's and Parkinson's disease. The findings revealed a notable enhancement in connectivity within the Default Mode Network (DMN) at the alpha, beta, and theta frequency bands among individuals undergoing chiropractic adjustments. CONCLUSIONS: We found that it is feasible to record EEG/SEP in individuals with Alzheimer's and Parkinson's disease. Additionally, a single session of chiropractic spinal adjustment reduced the somatosensory evoked N30 potential and enhancement in connectivity within the DMN at the alpha, beta, and theta frequency bands in individuals with Alzheimer's disease. Future studies may require a larger sample size to estimate the effects of chiropractic spinal adjustment on brain activity. Given the preliminary nature of our findings, caution is warranted when considering the clinical implications. CLINICAL TRIAL REGISTRATION: The study was registered by the Australian New Zealand Clinical Trials Registry (registration number ACTRN12618001217291 and 12618001218280).


Assuntos
Doença de Alzheimer , Estudos Cross-Over , Eletroencefalografia , Potenciais Somatossensoriais Evocados , Doença de Parkinson , Humanos , Feminino , Masculino , Doença de Parkinson/fisiopatologia , Doença de Parkinson/terapia , Idoso , Doença de Alzheimer/fisiopatologia , Doença de Alzheimer/terapia , Pessoa de Meia-Idade , Potenciais Somatossensoriais Evocados/fisiologia , Projetos Piloto , Manipulação Quiroprática/métodos
8.
HardwareX ; 18: e00529, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38690151

RESUMO

Understanding the somatosensory system and its abnormalities requires the development of devices that can accurately stimulate the human skin. New methods for assessing the somatosensory system can enhance the diagnosis, treatments, and prognosis for individuals with somatosensory impairments. Therefore, the design of NeuroSense, a tactile stimulator that evokes three types of daily life sensations (touch, air and vibration) is described in this work. The prototype aims to evoke quantitative assessments to evaluate the functionality of the somatosensory system and its abnormal conditions that affect the quality of life. In addition, the device has proven to have varying intensities and onset latencies that produces somatosensory evoked potentials and energy desynchronization on somatosensory cortex.

9.
Cereb Cortex ; 34(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38642106

RESUMO

The spatial coding of tactile information is functionally essential for touch-based shape perception and motor control. However, the spatiotemporal dynamics of how tactile information is remapped from the somatotopic reference frame in the primary somatosensory cortex to the spatiotopic reference frame remains unclear. This study investigated how hand position in space or posture influences cortical somatosensory processing. Twenty-two healthy subjects received electrical stimulation to the right thumb (D1) or little finger (D5) in three position conditions: palm down on right side of the body (baseline), hand crossing the body midline (effect of position), and palm up (effect of posture). Somatosensory-evoked potentials (SEPs) were recorded using electroencephalography. One early-, two mid-, and two late-latency neurophysiological components were identified for both fingers: P50, P1, N125, P200, and N250. D1 and D5 showed different cortical activation patterns: compared with baseline, the crossing condition showed significant clustering at P1 for D1, and at P50 and N125 for D5; the change in posture showed a significant cluster at N125 for D5. Clusters predominated at centro-parietal electrodes. These results suggest that tactile remapping of fingers after electrical stimulation occurs around 100-125 ms in the parietal cortex.


Assuntos
Percepção do Tato , Tato , Humanos , Tato/fisiologia , Dedos/fisiologia , Percepção do Tato/fisiologia , Mãos/fisiologia , Eletroencefalografia , Córtex Somatossensorial
10.
Cureus ; 16(3): e57014, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38681279

RESUMO

Cardiorespiratory arrest is a very common cause of morbidity and mortality nowadays, and many therapeutic strategies, such as induced coma or targeted temperature management, are used to reduce patient sequelae. However, these procedures can alter a patient's neurological status, making it difficult to obtain useful clinical information for the reliable estimation of neurological prognosis. Therefore, complementary investigations are conducted in the early stages after a cardiac arrest to clarify functional prognosis in comatose cardiac arrest survivors in the first few hours or days. Current practice relies on a multimodal approach, which shows its greatest potential in predicting poor functional prognosis, whereas the data and tools to identify patients with good functional prognosis remain relatively limited in comparison. Therefore, there is considerable interest in investigating alternative biological parameters and advanced imaging technique studies. Among these, somatosensory evoked potentials (SSEPs) remain one of the simplest and most reliable tools. In this article, we discuss the technical principles, advantages, limitations, and prognostic implications of SSEPs in detail. We will also review other types of evoked potentials that can provide useful information but are less commonly used in clinical practice (e.g., visual evoked potentials; short-, medium-, and long-latency auditory evoked potentials; and event-related evoked potentials, such as mismatch negativity or P300).

11.
Spine J ; 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38685276

RESUMO

BACKGROUND CONTEXT: Transcranial Motor Evoked Potentials (TcMEPs) can improve intraoperative detection of femoral plexus and nerve root injury during lumbosacral spine surgery. However, even under ideal conditions, TcMEPs are not completely free of false-positive alerts due to the immobilizing effect of general anesthetics, especially in the proximal musculature. The application of transcutaneous stimulation to activate ventral nerve roots directly at the level of the conus medularis (bypassing the brain and spinal cord) has emerged as a method to potentially monitor the motor component of the femoral plexus and lumbosacral nerves free from the blunting effects of general anesthesia. PURPOSE: To evaluate the reliability and efficacy of transabdominal motor evoked potentials (TaMEPs) compared to TcMEPs during lumbosacral spine procedures. DESIGN: We present the findings of a single-center 12-month retrospective experience of all lumbosacral spine surgeries utilizing multimodality intraoperative neuromonitoring (IONM) consisting of TcMEPs, TaMEPs, somatosensory evoked potentials (SSEPs), electromyography (EMG), and electroencephalography. PATIENT SAMPLE: Two hundred and twenty patients having one, or a combination of lumbosacral spine procedures, including anterior lumbar interbody fusion (ALIF), lateral lumbar interbody fusion (LLIF), posterior spinal fusion (PSF), and/or transforaminal lumbar interbody fusion (TLIF). OUTCOME MEASURES: Intraoperative neuromonitoring data was correlated to immediate post-operative neurologic examinations and chart review. METHODS: Baseline reliability, false positive rate, true positive rate, false negative rate, area under the curve at baseline and at alerts, and detection of pre-operative deficits of TcMEPs and TaMEPs were compared and analyzed for statistical significance. The relationship between transcutaneous stimulation voltage level and patient BMI was also examined. RESULTS: TaMEPs were significantly more reliable than TcMEPs in all muscles except abductor hallucis. Of the 27 false positive alerts, 24 were TcMEPs alone, and 3 were TaMEPs alone. Of the 19 true positives, none were detected by TcMEPs alone, 3 were detected by TaMEPs alone (TcMEPs were not present), and the remaining 16 true positives involved TaMEPs and TcMEPs. TaMEPs had a significantly larger area under the curve (AUC) at baseline than TcMEPs in all muscles except abductor hallucis. The percent decrease in TcMEP and TaMEP AUC during LLIF alerts was not significantly different. Both TcMEPs and TaMEPs reflected three pre-existing motor deficits. Patient BMI and TaMEP stimulation intensity were found to be moderately positively correlated. CONCLUSIONS: These findings demonstrate the high reliability and predictability of TaMEPs and the potential added value when TaMEPs are incorporated into multimodality IONM during lumbosacral spine surgery.

12.
Spine J ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38614157

RESUMO

BACKGROUND CONTEXT: Intraoperative neurophysiological monitoring (IONM) is used to reduce the risk of spinal cord injury during pediatric spinal deformity surgery. Significant reduction and/or loss of IONM signals without immediate recovery may lead the surgeon to acutely abort the case. The timing of when monitorable signals return remains largely unknown. PURPOSE: The goal of this study was to investigate the correlation between IONM signal loss, clinical examination, and subsequent normalization of IONM signals after aborted pediatric spinal deformity surgery to help determine when it is safe to return to the operating room. STUDY DESIGN/SETTING: This is a multicenter, multidisciplinary, retrospective study of pediatric patients (<18 years old) undergoing spinal deformity surgery whose surgery was aborted due to a significant reduction or loss of IONM potentials. PATIENT SAMPLE: Sixty-six patients less than 18 years old who underwent spinal deformity surgery that was aborted due to IONM signal loss were enrolled into the study. OUTCOME MEASURES: IONM data, operative reports, and clinical examinations were investigated to determine the relationship between IONM loss, clinical examination, recovery of IONM signals, and clinical outcome. METHODS: Information regarding patient demographics, deformity type, clinical history, neurologic and ambulation status, operative details, IONM information (eg, quality of loss [SSEPs, MEPs], laterality, any recovery of signals, etc.), intraoperative wake-up test, postoperative neurologic exam, postoperative imaging, and time to return to the operating were all collected. All factors were analyzed and compared with univariate and multivariate analysis using appropriate statistical analysis. RESULTS: Sixty-six patients were enrolled with a median age of 13 years [IQR 11-14], and the most common sex was female (42/66, 63.6%). Most patients had idiopathic scoliosis (33/66, 50%). The most common causes of IONM loss were screw placement (27/66, 40.9%) followed by rod correction (19/66, 28.8%). All patients had either complete bilateral (39/66, 59.0%), partial bilateral (10/66, 15.2%) or unilateral (17/66, 25.8%) MEP loss leading to termination of the case. Overall, when patients were returned to the operating room 2 weeks postoperatively, nearly 75% (40/55) had monitorable IONM signals. Univariate analysis demonstrated that bilateral SSEP loss (p=.019), bilateral SSEP and MEP loss (p=.022) and delayed clinical neurologic recovery (p=.008) were significantly associated with having unmonitorable IONM signals at repeat surgery. Multivariate regression analysis demonstrated that delayed clinical neurologic recovery (> 72 hours) was significantly associated with unmonitorable IONM signals when returned to the operating room (p=.006). All patients ultimately made a full neurologic recovery. CONCLUSIONS: In children whose spinal deformity surgery was aborted due to intraoperative IONM loss, there was a strong correlation between combined intraoperative SSEP/MEP loss, the magnitude of IONM loss, the timing of clinical recovery, and the time of electrophysiological IONM recovery. The highest likelihood of having a prolonged postoperative neurological deficit and undetectable IONM signals upon return to the OR occurs with bilateral complete loss of SSEPs and MEPs.

14.
BJA Educ ; 24(5): 173-182, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38646449
15.
Andrology ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38439166

RESUMO

INTRODUCTION: Primary intravaginal anejaculation (PIAJ) is a relatively uncommon male sexual dysfunction characterized by an inability to achieve intravaginal ejaculation during all sexual intercourse. Effective treatment options for this condition are lacking. We aimed to explore the clinical effect of the sexual therapy combined with vacuum negative pressure hydropneumatic/pneumatic bubble massage (VNPHP/PBM) on primary intravaginal anejaculation, and its possible mechanism. METHODS: A total of 95 PIAJ patients were randomly divided into three groups, including group A with 32 patients treated with the sexual therapy combined with VNPHP/PBM, group B with 32 patients treated with the sexual therapy and group C with 31 patients treated with VNPHP/PBM. The efficacy of therapeutic regimes, latency of the somatosensory evoked potentials of dorsal nerve (DNSEP), glans penis (GPSEP) and penile shaft sensory threshold (PSST), measures of sexual behavior of patients, as well as the self-rating anxiety scale (SAS) sores of patients and their partners, were compared before and after treatment among three groups. RESULTS: The total effective rate of group A (84.38%) was higher than those of groups B and C (53.13% and 41.94%), however, no differences were found between groups B and C. The ratios of patients and their partners with anxiety, frequency of observing erotic films of patients, ratios of patients with special self-masturbation and frequency of masturbation decreased significantly in the three groups after the treatment. The decrease in the ratios of patients and their partners with anxiety, frequency of observing erotic films of patients in groups A and B were higher than those of group C, however, no differences were identified between groups A and B. The decrease in the ratios of patients with special self-masturbation and frequency of masturbation in group A were higher than those of group B, however, no differences were found between groups A and C, B and C. There were no differences in the latency of DNSEP, GPSEP, and PSST among the three groups before and after treatment. CONCLUSION: The sexual therapy combined with VNPHP/PBM has good therapeutic effects on PIAJ, which might be achieved by reducing the anxiety level of patients and their partners, improving sexual behavioral patterns, rather than increasing the sensitivity of penis including dorsal nerve and glans penis.

16.
J Neural Transm (Vienna) ; 131(4): 359-367, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38456947

RESUMO

The different peaks of somatosensory-evoked potentials (SEP) originate from a variety of anatomical sites in the central nervous system. The origin of the median nerve subcortical N18 SEP has been studied under various conditions, but the exact site of its generation is still unclear. While it has been claimed to be located in the thalamic region, other studies indicated its possible origin below the pontomedullary junction. Here, we scrutinized and compared SEP recordings from median nerve stimulation through deep brain stimulation (DBS) electrodes implanted in various subcortical targets. We studied 24 patients with dystonia, Parkinson's disease, and chronic pain who underwent quadripolar electrode implantation for chronic DBS and recorded median nerve SEPs from globus pallidus internus (GPi), subthalamic nucleus (STN), thalamic ventral intermediate nucleus (Vim), and ventral posterolateral nucleus (VPL) and the centromedian-parafascicular complex (CM-Pf). The largest amplitude of the triphasic potential of the N18 complex was recorded in Vim. Bipolar recordings confirmed the origin to be close to Vim electrodes (and VPL/CM-Pf) and less close to STN electrodes. GPi recorded only far-field potentials in unipolar derivation. Recordings from DBS electrodes located in different subcortical areas allow determining the origin of certain subcortical SEP waves more precisely. The subcortical N18 of the median nerve SEP-to its largest extent-is generated ventral to the Vim in the region of the prelemniscal radiation/ zona incerta.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Núcleo Subtalâmico , Humanos , Potenciais Somatossensoriais Evocados/fisiologia , Núcleo Subtalâmico/fisiologia , Tálamo/fisiologia , Doença de Parkinson/terapia , Eletrodos , Globo Pálido , Eletrodos Implantados
17.
J Neurosci ; 44(19)2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38508711

RESUMO

In the study of bodily awareness, the predictive coding theory has revealed that our brain continuously modulates sensory experiences to integrate them into a unitary body representation. Indeed, during multisensory illusions (e.g., the rubber hand illusion, RHI), the synchronous stroking of the participant's concealed hand and a fake visible one creates a visuotactile conflict, generating a prediction error. Within the predictive coding framework, through sensory processing modulation, prediction errors are solved, inducing participants to feel as if touches originated from the fake hand, thus ascribing the fake hand to their own body. Here, we aimed to address sensory processing modulation under multisensory conflict, by disentangling somatosensory and visual stimuli processing that are intrinsically associated during the illusion induction. To this aim, we designed two EEG experiments, in which somatosensory- (SEPs; Experiment 1; N = 18; F = 10) and visual-evoked potentials (VEPs; Experiment 2; N = 18; F = 9) were recorded in human males and females following the RHI. Our results show that, in both experiments, ERP amplitude is significantly modulated in the illusion as compared with both control and baseline conditions, with a modality-dependent diametrical pattern showing decreased SEP amplitude and increased VEP amplitude. Importantly, both somatosensory and visual modulations occur in long-latency time windows previously associated with tactile and visual awareness, thus explaining the illusion of perceiving touch at the sight location. In conclusion, we describe a diametrical modulation of somatosensory and visual processing as the neural mechanism that allows maintaining a stable body representation, by restoring visuotactile congruency under the occurrence of multisensory conflicts.


Assuntos
Eletroencefalografia , Potenciais Somatossensoriais Evocados , Potenciais Evocados Visuais , Ilusões , Percepção Visual , Humanos , Masculino , Feminino , Adulto , Percepção Visual/fisiologia , Potenciais Somatossensoriais Evocados/fisiologia , Adulto Jovem , Ilusões/fisiologia , Potenciais Evocados Visuais/fisiologia , Percepção do Tato/fisiologia , Estimulação Luminosa/métodos , Conflito Psicológico , Córtex Somatossensorial/fisiologia , Imagem Corporal
18.
Resusc Plus ; 17: 100567, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38328749

RESUMO

Background: In neurologic prognostication of comatose survivors from cardiac arrest, two independent predictors of poor outcome are the loss of the Pupillary light reflex (PLR) and the loss of the N20 response from Somatosensory Evoked potentials (SSEP). The PLR can be quantitatively assessed by pupillometry. Both tests depend on the midbrain, in which a dysfunction reflects a severe hypoxic injury. We reasoned that a certain level of defective PLR would be predictive of a bilaterally absent SSEP N20 response. Method: Neurological Pupil index (NPi) from the pupillometry and the SSEP N20 response were registered >48 h after cardiac arrest in comatose survivors. Clinical data were retrospectively analyzed. A receiver operating characteristic curve was used to evaluate the capacity of NPi to predict bilaterally absent SSEP N20 response. An NPi threshold value resulting in <5% false positive rate (FPR) for bilaterally absent N20 response was identified. Results: From February 2020 to August 2022, we included 54 patients out of which 49 had conclusive pupillometry and SSEP examinations. The NPi threshold value with FPR < 5% was 3.4, yielding 36% sensitivity (95% CI 18-55) and significantly discriminated between respective groups with preserved and bilaterally absent N20 response to SSEP (p-value <0.01). Conclusion: In this limited cohort, NPi < 3.4 in patients remaining comatose >48 hours after cardiac arrest predicted bilateral loss of the SSEP N20 response with a FPR < 5%. If validated in a larger cohort, an NPi threshold may be clinically applied in settings where SSEP is unavailable.

19.
J Clin Med ; 13(3)2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38337607

RESUMO

Background: Neurodynamic exercise is a common clinical practice used to restore neural dynamic balance. The order in which movements are performed during these exercises is believed to play a crucial role in their effectiveness. This study aimed to investigate the impact of different sequences of neurodynamic exercise on nerve root function, with a specific focus on the median nerve. Methods: Participants were assigned randomly to three experimental groups, each undergoing a different test sequence: standard, proximal-to-distal, and distal-to-proximal. Dermatomal somatosensory evoked potentials (DSSEPs) were recorded at key levels (C6, C7, C8, and T1). Results: The findings revealed a significant influence of the movement sequence on DSSEP amplitudes. The execution of neurodynamic exercise in the proximal-to-distal sequence was associated with a notable reduction in amplitudes (p < 0.05). Conversely, the distal-to-proximal sequence resulted in increased amplitudes compared to the standard sequence (p < 0.05). Conclusions: This study underscores the importance of carefully considering the order of movements during neurodynamic exercising, particularly when evaluating nerve roots that lack the protective perineurium. The choice of sequence appears to have a substantial impact on nerve function, with implications for optimizing clinical neurodynamic exercise techniques.

20.
Vet J ; 304: 106082, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38360137

RESUMO

Electrodiagnostic (EDX) testing is uncommonly utilized in dogs other than for investigation of disorders of the neuromuscular system. In dogs with diseases affecting the spinal cord or cauda equina, EDX testing can provide functional data complementary to imaging information that together can guide therapeutic and management approaches. Additionally, in some clinical scenarios, EDX testing prior to advanced imaging is integral to identifying if there is spinal cord or cauda equina involvement and can aid in determining the appropriate diagnostic path. This review will outline EDX testing methods that have been reported in dogs relating to the diagnosis, monitoring or prognosis of various conditions affecting the spinal cord and cauda equina. The various tests will be briefly outlined regarding how they are performed and what information is provided. The main focus will be on clinical applications including highlighting situations where EDX testing is useful for differentiating between neurologic and non-neurologic presentations. Additional ways these EDX techniques could be incorporated in the management of diseases of the spinal cord and cauda equina in dogs will be presented.