Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
J Clin Med ; 13(15)2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39124720

RESUMO

Background/Objectives: Various parameters, like femoral offset and leg length, are associated with good patient outcomes after total hip arthroplasty. In this prospective study, the effects of stem design, its placement in the proximal femur and the resulting femoral offset on the total leg axis were investigated. Methods: The 27 patients included in this study received biplanar radiography (EOS®, EOS Imaging) with 3D reconstruction using sterEOS® both preoperatively and postoperatively. For all leg alignment parameters obtained from the 3D reconstruction and from measurements using mediCAD, the deltas between the postoperative and preoperative values were determined. Patients were divided into those who received a short-stem prosthesis and those who received a straight-stem prosthesis. Results: The change in femoral offset with the implantation of a short-stem prosthesis was significantly greater than that with the implantation of a straight-stem prosthesis (11.4 ± 5.9 vs. 4.6 ± 7.4 mm, p = 0.014). Compared with the straight-stem implantation, short-stem implantation caused a significantly greater increase in the varus orientation of the leg (-1.4 ± 0.9 vs. -0.4 ± 1.4°, p = 0.048). There was no significant difference in the positioning of the short-stem prosthesis compared to the straight-stem prosthesis in the proximal femur (3.6 ± 3.1 vs. 2.6 ± 1.9°, p = 0.317). Conclusions: These findings substantiate the impact of prosthesis design on offset and leg alignment. The implantation of short-stems is more variable and requires precise planning. Intraoperative non-physiological offset changes and varus deviation of the leg axis should be avoided. Trial registration: This study was retrospectively registered with the German Clinical Trials Register (DRKS) under the number DRKS00015053 on the 1 August 2018.

2.
J Clin Med ; 13(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38731155

RESUMO

Background: Total hip arthroplasty is one of the most successful orthopedic surgeries; nevertheless, many of these surgeries are the causes of failure, and among them, periprosthetic fractures are one of the major causes of revision. Our study focuses on periprosthetic hip fractures with two different stem designs. The aim of the study was to analyze the obtained results, focusing on the features of periprosthetic stem fractures observed. Methods: We retrospectively reviewed periprosthetic fractures occurring between 2010 and 2023, involving Alloclassic® or CLS® uncemented femoral stems. We analyzed demographic data, proximal femur morphology, and the fracture type. Results: We identified 97 patients. Considering the proximal femur morphology, we found that there was statistically significant prevalence of Dorr A proximal femur morphology in the CLS® group and of Dorr C in the Alloclassic® group. Considering the distribution of the fracture pattern, we reported a non-statistically significant prevalence of the fracture pattern with stable stems in the CLS® group. Conclusions: The choice of the prosthetic design of the femoral stem is a crucial element when planning total hip arthroplasty. However, we found a non-statistically significant difference between the two stems considered, raising questions about the real role of stem design as a primary determinant of periprosthetic hip fractures.

3.
Arch Orthop Trauma Surg ; 144(5): 2283-2295, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38625551

RESUMO

INTRODUCTION: The rate of revision TKA and thus the use of hinged implants (HI) steadily rises. Aseptic loosening lies on the top of the failure patterns. However, no evidence exists until now based on national scale high-caseloads that analyzes the impact of cemented HI stem-design on aseptic survival rates. METHODS: Data on aseptic HI-revisions with full-cemented tibia-stems were conducted from the German Arthroplasty Registry. Cases were divided in primary HI (PHI) and HI used in revision operations (RHI). Endpoint was a new revision following either a PHI or an RHI. The impact of stem conicity (conical vs. cylindrical), diameter (≤ 13 mm vs. > 13 mm), length (≤ 90 mm vs. > 90 mm) and offset on the 6-Year-Cumulative-Aseptic-Revision-Rate (6Y-CARR) was estimated via Kaplan-Meier curve and compared between groups via Log-Rank-Tests. RESULTS: 3953 PHI and 2032 RHI fulfilled inclusion-criteria. Stem conicity had no impact on 6Y-CARR (p = 0.08 and p = 0.8). Diameter > 13 mm hat an impact on PHI (p = 0.05) with lower 6Y-CARR but not on RHI (p = 0.2). Length > 90 mm showed significantly worst 6Y-CARR in PHI (p = 0.0001) but not in RHI (p = 0.3). Offset-stems showed significantly better 6Y-CARR in PHI (p = 0.04), but not in RHI (p = 0.7). CONCLUSION: There was no significant impact of the cemented tibia-stem conicity on 6Y-CARR, neither in PHI nor in RHI. The effect of length, diameter and offset on the 6Y-CARR observed in the PHI, was not detectable in the more complex RHI-cases reflecting its limited clinical relevance by itself in more multifactorial backgrounds. Therefore, results must be interpreted with caution due to considerable system-effects and different utilization-scenarios.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Reoperação , Humanos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/instrumentação , Alemanha/epidemiologia , Reoperação/estatística & dados numéricos , Masculino , Idoso , Feminino , Tíbia/cirurgia , Pessoa de Meia-Idade , Cimentos Ósseos
4.
J Shoulder Elbow Surg ; 33(6S): S86-S92, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38518886

RESUMO

BACKGROUND: Aseptic humeral stem loosening is an uncommon complication of shoulder arthroplasty, and its presence has been considered a highly specific predictor of prosthetic joint infection (PJI). Literature on aseptic humeral stem loosening is sparse. The primary purpose of this study was to determine the rate of aseptic humeral loosening in revision shoulder arthroplasty. Secondarily, we sought to identify predictors of septic and aseptic humeral loosening. METHODS: Our institutional revision shoulder arthroplasty database was reviewed. Inclusion criteria were patients with humeral stem loosening as indicated in the operative report. Patient demographics, index surgery and indication, revision surgery and indication, and operative data were recorded. Charts were manually reviewed, and PJI scores were calculated using the International Consensus Meeting scoring criteria. International Consensus Meeting classifications of PJI "unlikely" and "possible" were considered aseptic, and PJI "probable" and "definite" were considered septic. Statistical analysis was performed to determine associations between the abovementioned variables and aseptic humeral loosening. RESULTS: Forty-six patients with 48 shoulders were included in our analysis. Ten cases (21%) were classified as definite PJI, 13 cases (27%) were classified as probable PJI, 4 cases (8%) were classified as possible PJI, and 21 cases (44%) were classified as PJI unlikely. On analysis of stem design, there were no statistically significant associations with aseptic loosening; although, a lack of proximal porous ingrowth surface trended toward higher rates of aseptic loosening in all patients and in anatomic total shoulder arthroplasty (ATSA) and reverse total shoulder arthroplasty (RTSA) subgroup analyses. In the index RTSA subgroup, aseptic loosening was associated with female sex (P = .005). Seventeen of 39 shoulders (44%) that underwent either index ATSA or RTSA demonstrated concomitant glenoid loosening. The absence of glenoid loosening was associated with aseptic humeral loosening in index ATSA and RTSA (P < .001). CONCLUSION: Fifty-two % of revision shoulder arthroplasty cases with humeral loosening performed at our institution were aseptic. There appear to be distinct demographic and radiographic factors that are more commonly associated with aseptic as opposed to septic humeral loosening. Our data demonstrate that demographic predictors of aseptic loosening of RTSA include female sex. The absence of glenoid component loosening is associated with aseptic humeral loosening and concomitant glenoid loosening is associated with septic humeral loosening. Understanding of these factors can guide the preoperative index of suspicion for PJI in the setting of humeral stem loosening.


Assuntos
Artroplastia do Ombro , Falha de Prótese , Infecções Relacionadas à Prótese , Reoperação , Prótese de Ombro , Humanos , Feminino , Masculino , Idoso , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Artroplastia do Ombro/efeitos adversos , Pessoa de Meia-Idade , Prótese de Ombro/efeitos adversos , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Úmero/cirurgia , Articulação do Ombro/cirurgia , Adulto
5.
J Orthop Sci ; 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38302311

RESUMO

BACKGROUND: Intraoperative femoral fractures are more common in cementless bipolar hip arthroplasty (BHA) for displaced femoral neck fractures than they are in cemented BHA and remain one of the major concerns. This study aimed to investigate the risk factors for intraoperative femoral fractures in cementless BHA. METHODS: The study included 1,392 patients who underwent cementless BHA for displaced femoral neck fractures from January 2015 to December 2019 in 14 hospitals of the Trauma Research Group. They were divided into two groups according to the presence or absence of intraoperative femoral fractures, and factors associated with intraoperative fractures were statistically examined. RESULTS: Forty (2.9 %) intraoperative and 28 (2.0 %) postoperative, totally 68 (4.9 %) femoral fractures occurred. The mean age of the patients, presence of opposite-side proximal femoral fracture, approach, and cementless stem design were significantly different between the two groups (P < 0.05). The logistic regression analysis model showed that a fully HA-coated stem (odds ratio, 4.12; 95 % confidence interval, 1.43-11.9) was an independent factor associated with intraoperative femoral fractures. CONCLUSION: This study investigated the risk factors associated with intraoperative fractures and showed that fully HA-coated stems were an independent factor associated with intraoperative femoral fractures. Surgeons should be cautious in the early stages of introducing fully HA-coated stems.

6.
Arch Orthop Trauma Surg ; 144(2): 917-926, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37796284

RESUMO

BACKGROUND: The influence of THA stem design on periprosthetic femoral fractures (PFFs) risk is subject of debate. This study aims to compare the effects of different cementless stem designs on stress-strain distributions in both physiological and osteoporotic femur under various loading conditions. MATERIALS: A biomechanical study using finite-element analysis was conducted. Four models were developed: three with implanted femurs and a native one chosen as control. Each model was analyzed for both healthy and osteoporotic bone. The following stem designs were examined: short anatomical stem with femoral neck preservation, double-wedge stem, and anatomical standard stem. Three loading conditions were assessed: gait, sideways falling, and four-point bending. RESULTS: During gait in physiological bone, the anatomical stem and the short anatomical stem with femoral neck preservation showed stress distribution similar to the native model. The double-wedge stem reduced stress in the proximal area but concentrated it in the meta-diaphysis. In osteoporotic bone, the double-wedge stem design increased average stress by up to 10%. During sideways falling, the double-wedge stem exhibited higher stresses in osteoporotic bone. No significant differences in average stress were found in any of the studied models during four-point bending. CONCLUSION: In physiological bone, anatomical stems demonstrated stress distribution comparable to the native model. The double-wedge stem showed uneven stress distribution, which may contribute to long-term stress shielding. In the case of osteoporotic bone, the double-wedge stem design resulted in a significant increase in average stress during both gait and sideways falling, potentially indicating a higher theoretical risk of PFF.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Osteoporose , Fraturas Periprotéticas , Humanos , Artroplastia de Quadril/métodos , Fêmur/cirurgia , Fraturas Periprotéticas/cirurgia , Desenho de Prótese
7.
Proc Inst Mech Eng H ; 237(10): 1154-1166, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37747115

RESUMO

Primary stability is crucial for implant osseointegration and the long-term stability of cementless total joint replacements. Biomechanical studies have shown the potential of femoral stems for total knee replacements to reduce micromotions at the bone-implant interface. However, approaches such as focusing on the structural elasticity of the femoral stems are rarely described. Three groups with different femoral stem designs were investigated: group 1: flexible surface stem, group 2: flexible surface stem with open-porous structured lamellas, and group 3: solid stem (reference). The stems were implanted into bone substitute material and dynamically loaded for 1000 cycles. Relative movement and subsidence were measured optically, and axial pull-out forces were determined after dynamic testing. Relative movements increased to 0.10 mm (groups 1 and 2) compared to 0.03 mm (group 3). Subsidence increased to 0.08 mm (group 1) and 0.11 mm (group 2) compared to 0.06 mm (group 3). For each group, subsidence mainly occurred during the first 500 cycles. A similar convergence was observed in the further course. Pull-out forces increased to 1815.0 N (group 1) and 1347.1 N (group 2) compared to 1306.4 N (group 3). The flexible surface stem design resulted in higher relative movements and subsidence, but also exhibited increased pull-out forces. The relative movements were below the critical limit of 0.15 mm and represent a superposition of the elastic deformations of the interacting implant components as well as the micromotion at the bone-implant interface. Therefore, the novel flexible surface stem design appears to offer promising primary implant fixation.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Prótese de Quadril , Desenho de Prótese , Osseointegração , Fêmur/cirurgia
8.
BMC Geriatr ; 23(1): 553, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-37700237

RESUMO

BACKGROUND: The optimal treatment of displaced proximal humerus fractures (PHFs) in the older people population remains controversial. Reverse shoulder arthroplasty (RSA) is a popular surgical treatment option that provides improved and reproducible results. However, the relevance of fracture-specific stem designs for RSA to improve tuberosity consolidation and shoulder function remains debatable. METHODS: This study included all patients 70 years or older with acute and displaced PHFs primarily treated with RSA at a single institution in Portugal, between January 2010 and December 2019 who participated in a minimum follow-up of 2 years. RESULTS: A total of 112 patients (15 men and 97 women) with a median clinical follow-up of 52 months were included. The mean age at the time of fracture was 78.6 years. All fractures were classified as Neer types 3 and 4 (n = 50 and n = 62, respectively). A window bone ingrowth fracture-specific stem was used for 86 patients, and a conventional humeral stem was used for 26 patients. Regarding the tuberosity fixation technique, 76 tuberosities were attached using technique A (according to Boileau's principles), 36 tuberosities were attached using technique B (not following Boileau's principles) and 11cases were classified as technique C (if fixation was not possible). The overall survival rate during the 2-year follow-up was 88.2%; however, this decreased to 79% at 5 years. Only three patients had complications (two infections and one dislocation) requiring revision surgery. In the multivariable analysis, the tuberosity fixation technique (P = 0.012) and tuberosity anatomical consolidation (P < 0.001) were associated with improved Constant scores (median Constant Score 62.67 (technique A), 55.32 (technique B), 49.70 (technique C). Fracture-specific humeral implants (P = 0.051), the tuberosity fixation technique (P = 0.041), tuberosity anatomical consolidation (P < 0.001), and dementia influenced the achievement of functional mobility (P = 0.014). Tuberosity anatomic consolidation was positively associated with bone ingrowth fracture-specific humeral implants (P < 0.01) and a strong tuberosity fixation technique (P < 0.01). CONCLUSION: RSA is used for complex and displaced fractures of the proximal humerus in older patients. Dementia was negatively correlated with functional outcomes. A window bone ingrowth fracture-specific stem combined with strong tuberosity fixation can yield better clinical and radiological results. LEVEL OF EVIDENCE: Level II; prospective comparative study; treatment study.


Assuntos
Artroplastia do Ombro , Demência , Fraturas do Úmero , Masculino , Humanos , Feminino , Idoso , Estudos Prospectivos , Reoperação
9.
Med Eng Phys ; 119: 104032, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37634909

RESUMO

Due to the increasing number of periprosthetic femoral fractures (PFF), the optimisation of implant design gains importance. For the presented research a validated, subject specific finite element model of a human femur with an inlying total hip stem was used to compare the influence of different geometrical implant parameters on the development of PFF. The heterogeneous bone tissue was modelled on the basis of computed tomography scans. A ductile damage model with element deletion was applied to simulate bone fracture in a load case re-enacting a stumbling scenario. The results were compared in terms of fracture load, subsidence and fracture pattern to analyse the influence of friction at the implant-bone interface, implant size and stem length. The results showed that higher friction coefficients lead to an increase of fracture load. Also, the usage of an oversized implant has a negligible effect while an undersized implant reduces the fracture load by 48.9% for the investigated femur. Lastly, a higher fracture load was reached with an elongated stem, but the bending and change in fracture path indicate a more distal force transmission and subsequent stress shielding in the proximal femur.


Assuntos
Fraturas do Fêmur , Humanos , Análise de Elementos Finitos , Fêmur , Extremidade Inferior , Osso e Ossos
10.
Hip Int ; 33(3): 434-441, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35438031

RESUMO

BACKGROUND: Preoperative planning is a fundamental step for successful total hip arthroplasty (THA). Studies have highlighted the accuracy of preoperative digital templating for estimating acetabular cup and stem size. Stem design such as single-wedge metadiaphyseal (Type 1 stem) versus mid-short stem (microplasty) and surgical approach (anterior, direct lateral or posterior) have not been well investigated as predictors of THA templating accuracy. METHODS: 204 patients (220 hips) who had undergone elective THA between November 2016 and December 2019 and presented a saved preoperative template were retrospectively reviewed. Templates from 5 different surgeons were involved in the analysis. 3 different approaches were used: direct lateral (DL), posterior (PA), direct anterior (DAA). 2 different stem designs were used: single-wedge metadiaphyseal and single-wedge mid-short (Biomet Taperloc Microplasty), while the acetabular component remained the same. Bivariate and multivariate regression analyses were performed to determine predictors of accuracy. RESULTS: Femoral component size templating accuracy was significantly improved when using the single-wedge mid-short stem (Taperloc Microplasty) design when performing bivariate analysis. Although accuracy of cup sizing was not affected by approach, precision was significantly better in the PA group (p < 0.05). Accuracy of templating was found to be independent of BMI and gender but dependent on presence of calibration marker and stem design (p < 0.05). CONCLUSIONS: When striving for improved templating accuracy, acetabular and femoral component accuracy were best achieved using a calibration marker and a metaphyseal short femoral stem design.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Estudos Retrospectivos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Cuidados Pré-Operatórios , Articulação do Quadril/cirurgia
11.
Arch Orthop Trauma Surg ; 143(1): 469-479, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35930052

RESUMO

INTRODUCTION: While re-revision total knee arthroplasty (ReRTKA) steadily increases, the ease and bone-sparing removal of RTKA implants is gaining more and more in importance. Biomechanical data suggest that cemented conical stems can be removed significantly easier than cylindrical stems. However, no clinical evidence exists supporting this observation. Aim of this study was to compare the revisability and need for osteotomy (OT) between removals of well-fixed cemented conical vs. cylindrical RTKA stems. MATERIALS AND METHODS: 55 removals of well-fixed full-cemented RTKA stems (29 knees) performed between 2016 and 2018 were retrospectively analyzed. Main outcome variables were: bone loss, fractures, osteotomy incidence, surgery duration, early postoperative complications (EPC), hemoglobin drop and blood transfusion. SPSS was used for the statistical analysis. RESULTS: 44.8% were conical, 48.3% cylindrical, and 6.9% combined stem designs. Causes for re-revision were PJI (75.9%), malposition (17.2%) and persistent pain (6.9%). 10 stem removals (18.2%) required an OT (four femoral, six tibial): eight stems (14.5%) had cylindrical and two (3.6%) conical designs (P = 0.041). Fractures were noted solely in removals without OT (11.1% vs. 0%,). There was a tendency to more bone loss in cylindrical stem revisions (53.8% vs. 32%, P = 0.24). A longer overall surgery time was observed in revisions of cylindrical stems (+ 37 min, P = 0.05). There was higher hemoglobin drop and need for blood transfusion in revisions of cylindrical stems or after OT but without reaching statistical significance. The EPC rates were slightly higher in ReRTKA on cylindrical stems (P = 0.28). CONCLUSION: Well-fixed cemented conical stems may be revision friendlier with less demands on OT and shorter overall surgery time than cemented cylindrical stems.


Assuntos
Artroplastia do Joelho , Fraturas Ósseas , Prótese do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Fraturas Ósseas/complicações , Hemoglobinas , Prótese do Joelho/efeitos adversos , Osteotomia/efeitos adversos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
12.
Arch Orthop Trauma Surg ; 143(3): 1549-1569, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36450936

RESUMO

INTRODUCTION: Revision total knee arthroplasty (RTKA) has been increasing continuously. The results of RTKA still remain unsatisfactory. Failure patterns and risk factors in RTKA were thoroughly analyzed, with periprosthetic joint infections (PJI) and aseptic loosening remaining at the forefront of re-revision (ReRTKA) causes. While there is evidence that stem profile impacts the revisability of cemented implants, its association with the modes of RTKA failure is unknown. METHODS: 50 consecutive ReRTKA performed in a single orthopedic center during 2016-2017 were retrospectively analyzed. The cases were stratified according to age, sex, number of preexisting revisions, fixation technique, stem design and causes of re-revision. All explanted implants with conical vs. cylindrical stem profiles were compared. RESULTS: Mean age was 67 ± 11.5, and 54% were females. 72% of the cases had ≥ 3 previous revisions. 88% were full-cemented, 3% hybrid and 9% press-fit stems. 36% of the RTKA had conical, 58% cylindrical and 6% combined stem profiles. 92% of the RTKA components were removed. Removal causes were: PJI (52.2%), aseptic loosening (34.8%), implant malposition (9.8%), painful knee (1.1%) and instability (2.2%). While the overall RTKA failure patterns were equally distributed between conical and cylindrical stems, subgroup analysis of only cemented ReRTKA revealed a higher incidence of aseptic loosening within cylindrical stem profiles (46.7% vs. 25.7%, P = 0.05). CONCLUSION: Stem profile may have an impact on the process of aseptic loosening in cemented non-metaphyseal engaging RTKA, with cylindrical designs tending to worse outcomes than conical designs. Large cohort studies could provide more clarity on current observation.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Artroplastia do Joelho/efeitos adversos , Prótese do Joelho/efeitos adversos , Estudos Retrospectivos , Falha de Prótese , Reoperação/métodos , Desenho de Prótese
13.
BMC Musculoskelet Disord ; 23(1): 1035, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36451134

RESUMO

BACKGROUND: The preservation or restoration of hip geometry following total hip arthroplasty (THA) is of importance, considering that alterations in the centrum-collum-diaphysis (CCD)-angle, femoral offset (FO), acetabular offset (AO) and total offset (TO) change hip biomechanics. Therefore, the most suitable implant should be used. The aim of this study was to compare the ability of two short-stem-systems and one straight-stem-system to reconstruct hip geometry. METHODS: Two-hundred-fifty-one patients (mean age: 62.0 ± 10.0 years; 51.8% males) undergoing THA with three different stem types were retrospectively included, after excluding 11 patients with missing radiological follow-up. Pre- and postoperative radiographic images (group I, ANA.NOVA Alpha Schaft Proxy®, ImplanTec, 12 options: n = 99; group II, Optimys® Mathys, 24 options: n = 62; group III: Corail®-System, DePuy-Synthes, 76 options: n = 90) were analyzed. Differences in pre- and postoperative hip geometry (i.e. CCD, FO, AO, TO) were compared between groups with one-way-analysis-of-variance (ANOVA), and post-hoc t-tests. RESULTS: The CCD-angle increased by a mean of 8.4° ± 7.2° from pre-to postoperative, with no significant difference between groups (p = 0.097). Significantly larger increases in FO were observed for groups II (4.1 mm ± 7.8 mm) and III (4.9 ± 7.2 mm), in comparison to group I (1.6 ± 6.9 mm; p = 0.006). AO decreased by a mean of 2.2 ± 4.5 mm, with the largest decrease observed in group III (-3.3 ± 5.3 mm), and the smallest for group I (-1.4 ± 3.6 mm; p = 0.011). There was no significant difference in change of TO between groups (p = 0.177). CONCLUSIONS: Reconstruction of hip geometry using a single-version novel short-stem-system is achievable with comparable results to stem-systems offering multiple options.


Assuntos
Artroplastia de Quadril , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Retrospectivos , Acetábulo , Fêmur , Período Pós-Operatório
14.
Bone Joint Res ; 11(5): 270-277, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35514237

RESUMO

AIMS: Periprosthetic hip fractures (PPFs) after total hip arthroplasty are difficult to treat. Therefore, it is important to identify modifiable risk factors such as stem selection to reduce the occurrence of PPFs. This study aimed to clarify differences in fracture torque, surface strain, and fracture type analysis between three different types of cemented stems. METHODS: We conducted biomechanical testing of bone analogues using six cemented stems of three different types: collarless polished tapered (CPT) stem, Versys Advocate (Versys) stem, and Charnley-Marcel-Kerboull (CMK) stem. Experienced surgeons implanted each of these types of stems into six bone analogues, and the analogues were compressed and internally rotated until failure. Torque to fracture and fracture type were recorded. We also measured surface strain distribution using triaxial rosettes. RESULTS: There was a significant difference in fracture torque between the three stem types (p = 0.036). Particularly, the median fracture torque for the CPT stem was significantly lower than that for the CMK stem (CPT vs CMK: 164.5 Nm vs 200.5 Nm; p = 0.046). The strain values for the CPT stem were higher than those for the other two stems at the most proximal site. The fracture pattern of the CPT and Versys stems was Vancouver type B, whereas that of the CMK stem was type C. CONCLUSION: Our study suggested that the cobalt-chromium alloy material, polished surface finish, acute-square proximal form, and the absence of a collar may be associated with lower fracture torque, which may be related to PPF. Cite this article: Bone Joint Res 2022;11(5):270-277.

15.
Proc Inst Mech Eng H ; : 9544119221075140, 2022 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-35139695

RESUMO

Reducing stress shielding of stem-inserted femurs in total hip arthroplasty caused by the high stiffness of the stem is an emerging medical engineering issue. In this study, a numerical design optimization methodology lattice infill stem was developed to realize a stem, balancing the low stiffness and strength requirements. Two pairs of models and loading conditions were introduced for the stress shielding and strength criteria. The objective function was set as the weighted sum of the criteria. Its effective density distribution was optimized by handling the representative size of the lattice as a design variable, assuming that the so-called body-centered cubic lattice was the base shape of the lattice. In the optimization, the approximated model of the lattice was handled as a solid material with the effective physical properties of the lattice derived by the homogenization method. After optimization, the detailed lattice stem geometry was modeled based on the obtained optimal lattice distribution, and the actual performance was numerically evaluated. The developed stem increased the stress applied to the remaining femur by 32.4% compared with the conventional stem.

16.
Bone Joint J ; 104-B(1): 19-26, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34969272

RESUMO

AIMS: Highly polished stems with force-closed design have shown satisfactory clinical results despite being related to relatively high early migration. It has been suggested that the minimal thickness of cement mantles surrounding the femoral stem should be 2 mm to 4 mm to avoid aseptic loosening. The line-to-line cementing technique of the femoral stem, designed to achieve stem press-fit, challenges this opinion. We compared the migration of a highly polished stem with force-closed design by standard and line-to-line cementing to investigate whether differences in early migration of the stems occur in a clinical study. METHODS: In this single-blind, randomized controlled, clinical radiostereometric analysis (RSA) study, the migration pattern of the cemented Corail hip stem was compared between line-to-line and standard cementing in 48 arthroplasties. The primary outcome measure was femoral stem migration in terms of rotation and translation around and along with the X-, Y-, and Z- axes measured using model-based RSA at three, 12, and 24 months. A linear mixed-effects model was used for statistical analysis. RESULTS: Results from mixed model analyses revealed a lower mean retroversion for line-to-line (0.72° (95% confidence interval (CI) 0.38° to 1.07°; p < 0.001), but no significant differences in subsidence between the techniques (-0.15 mm (95% CI -0.53 to 0.227; p = 0.429) at 24 months. Radiolucent lines measuring < 2 mm wide were found in three and five arthroplasties cemented by the standard and line-to-line method, respectively. CONCLUSION: The cemented Corail stem with a force-closed design seems to settle earlier and better with the line-to-line cementing method, although for subsidence the difference was not significant. However, the lower rate of migration into retroversion may reduce the wear and cement deformation, contributing to good long-term fixation and implant survival. Cite this article: Bone Joint J 2022;104-B(1):19-26.


Assuntos
Artroplastia de Quadril/métodos , Cimentação/métodos , Prótese de Quadril , Idoso , Cimentos Ósseos , Feminino , Migração de Corpo Estranho/prevenção & controle , Humanos , Masculino , Noruega , Falha de Prótese , Análise Radioestereométrica , Rotação , Método Simples-Cego
17.
Hip Int ; 32(1): 99-105, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32459520

RESUMO

OBJECTIVES: Cemented polished tapered stems have demonstrated excellent long-term outcomes. Based on this concept, many generic tapered stems have been released into the market. The aim of this study was to evaluate implant-related complications of 1 specific stem design. METHODS: Between 2010 and 2017, 315 total hip replacements were performed using a Fortress stem (Biotechni, La Ciotat, France). Patient records and radiology were retrospectively reviewed for implant-related complications. A failure analysis was performed on the failed Fortress stems in order to determine the cause of premature failure. RESULTS: 7 (2.2%) patients sustained a fracture of the neck of the implant after a mean of 5 years (range 50-81 months). All fractures were atraumatic, originating at the introducer inlet of the stem. All fractured occurred in obese patients (BMI >33 kg/m2) with a small sized prosthesis. Of these, there were 5 135° and 2 125° stems. Fracture risk was 23% (7/30) for patients with a small sized stem and a BMI >30 kg/m2. All cases were revised using a cement-in-cement technique or a cementless modular revision stem. Failure analysis on the retrieved stems revealed a stress riser at the bottom of the introducer inlet. CONCLUSIONS: An alarmingly high rate of early implant fractures was seen using this specific type of cemented stem, particularly when using smaller implant sizes in obese patients. Although based on a proven design, a specific modification led to a stress riser in the neck area, which resulted in a high incidence of implant failure. This series underlines the importance of a stepwise introduction into the market of new orthopaedic devices even when based on established concepts. Generic stems may not behave as the original stem upon which it was designed.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Humanos , Fraturas Periprotéticas/diagnóstico por imagem , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
18.
Cureus ; 13(11): e19745, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34938623

RESUMO

INTRODUCTION: A comprehensive comparison of the performance of different femoral stem geometries in total hip arthroplasty (THA) is yet to be described. The primary aim of this study was to evaluate objective and subjective outcome measures in primary THA with different femoral implant styles. METHODS: Stems were classified into the following five classes: cemented, conical, fit and fill, modular, and wedge. The objective outcomes of interest were the length of inpatient hospital stay (LOS), 90-day readmission rate, one-year revision rate, and two-year mortality rate. Preoperative and postoperative patient-reported outcome measures (PROMs), including hip disability and osteoarthritis outcome score (HOOS) - physical function shortform (HOOS-PS), patient-reported outcomes measurement information system physical function short form 10a (PROMIS PF-10a), and patient-reported outcomes measurement information system - short form - mental 10a (PROMIS M-10a) were recorded and compared between different classes. RESULTS: Patients with a wedge stem had a significantly lower LOS versus every other stem group, while patients with a cemented stem had the highest LOS, approximately twofold that of the wedge stem group. Accounting for potential confounders, the conical and fit and fill groups had a significantly higher two-year mortality rate than the wedge stem group. Fit and fill stems conferred a slight risk of revision THA at one-year compared to wedge stems. There was no significant difference in the rates of failure to achieve the minimal clinically important difference (MCID) for the PROMs. CONCLUSION: Placement of wedge stems resulted in a significantly lower LOS compared to every other stem class and a lower mortality rate than the conical, fit and fill, and modular stems. As for the 90-day readmission, one-year revision, and the rates of failure to achieve the MCID for general or hip-specific PROMs, stem design had no meaningful effect.

19.
Orthop Clin North Am ; 52(4): 297-304, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34538342

RESUMO

The direct anterior approach (DAA) is gaining popularity in primary total hip arthroplasty (THA). Although DAA has demonstrated many advantages over other surgical approaches, periprosthetic femur fractures (PPFF) rates continue to be higher. Femoral stem designs that allow for easier insertion via a DAA may contribute to the higher rates of fracture seen in this approach. Certain stem designs and fixation methods may reduce the risk of PPFF via a DAA in primary THA.


Assuntos
Artroplastia de Quadril/efeitos adversos , Fixação de Fratura/métodos , Fraturas do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Fraturas Periprotéticas/cirurgia , Desenho de Prótese/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Cimentos Ósseos , Cimentação , Fraturas do Quadril/etiologia , Fraturas do Quadril/terapia , Humanos , Fraturas Periprotéticas/etiologia , Reoperação
20.
J Clin Med ; 10(18)2021 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-34575254

RESUMO

Reverse total shoulder arthroplasty (RTSA) is increasingly used for the treatment of complex proximal humerus fractures and fracture sequelae. In 2021, half a dozen models of fracture stems are commercially available, reflecting its growing utility for fracture management. Prosthesis designs, bone grafting and tuberosity fixation techniques have evolved to allow better and more reliable fixation of tuberosities and bony ingrowth. Patients with anatomical tuberosity healing not only have an increased range of active anterior elevation and external rotation, but also experience fewer complications and longer prosthesis survival. This review provides an overview of recent evidence on basic and fracture-specific RTSA design features as well as tuberosity fixation techniques that can influence tuberosity healing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA