Am J Physiol Regul Integr Comp Physiol ; 326(6): R588-R598, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38682241

RESUMO

Type 2 diabetes (T2D) is associated with reduced whole body sweating during exercise-heat stress. However, it is unclear if this impairment is related to exercise intensity and whether it occurs uniformly across body regions. We evaluated whole body (direct calorimetry) and local (ventilated-capsule technique; chest, back, forearm, thigh) sweat rates in physically active men with type 2 diabetes [T2D; aged 59 (7) yr; V̇o2peak 32.3 (7.6) mL·kg-1·min-1; n = 26; HbA1c 5.1%-9.1%] and without diabetes [Control; aged 61 (5) yr; V̇o2peak 37.5 (5.4) mL·kg-1·min-1; n = 26] during light- (∼40% V̇o2peak), moderate- (∼50% V̇o2peak), and vigorous- (∼65% V̇o2peak) intensity exercise (elicited by fixing metabolic heat production at ∼150, 200, 250 W·m-2, respectively) in 40°C, ∼17% relative humidity. Whole body sweating was ∼11% (T2D: Control mean difference [95% confidence interval]: -37 [-63, -12] g·m-2·h-1) and ∼13% (-50 [-76, -25] g·m-2·h-1) lower in the T2D compared with the Control group during moderate- and vigorous- (P ≤ 0.001) but not light-intensity exercise (-21 [-47, 4] g·m-2·h-1; P = 0.128). Consequently, the diabetes-related reductions in whole body sweat rate were 2.3 [1.6, 3.1] times greater during vigorous relative to light exercise (P < 0.001). Furthermore, these diabetes-related impairments in local sweating were region-specific during vigorous-intensity exercise (group × region interaction: P = 0.024), such that the diabetes-related reduction in local sweat rate at the trunk (chest, back) was 2.4 [1.2, 3.7] times greater than that at the limbs (thigh, arm). In summary, when assessed under hot, dry conditions, diabetes-related impairments in sweating are exercise intensity-dependent and greater at the trunk compared with the limbs.NEW & NOTEWORTHY This study evaluates the influence of exercise intensity on decrements in whole body sweating associated with type 2 diabetes. Furthermore, it investigates whether diabetes-related sweating impairments were exhibited uniformly or heterogeneously across body regions. We found that whole body sweating was attenuated in the type 2 diabetes group relative to control participants during moderate- and vigorous-intensity exercise but not light-intensity exercise; impairments were largely mediated by reduced sweating at the trunk rather than the limbs.


Assuntos
Diabetes Mellitus Tipo 2 , Exercício Físico , Sudorese , Humanos , Diabetes Mellitus Tipo 2/fisiopatologia , Diabetes Mellitus Tipo 2/metabolismo , Masculino , Pessoa de Meia-Idade , Exercício Físico/fisiologia , Idoso , Estudos de Casos e Controles , Regulação da Temperatura Corporal
2.
Biosens Bioelectron ; 257: 116299, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38636318

RESUMO

Skin-interfaced microfluidic patch has become a reliable device for sweat collection and analysis. However, the intractable problems of emptying the microchannel for reuse, and the channel's volumetric capacity limited by the size of the patch, directly hinder the practical application of sweat sensors. Herein, we report an adaptively resettable microfluidic sweat patch (Art-Sweat patch) capable of continuously monitoring both sweat rate (0.2-4.0 µL min-1) and total ionic charge concentration (10-200 mmol L-1). We develop a platform with a vertical and horizontal microchannel combined strategy, enabling repeatedly filling sweat and emptying the microchannel for autonomously resetting and detecting. The variation in the emptied volume is designed to be adaptively identified by the sensor, resulting in enhanced stability and an enlarged volumetric capacity of over 300 µL. By integrating with self-designed wireless transmission modules, the proposed Art-Sweat patch shows product-level wearability and high performance in monitoring variations in regional sweat rate and concentration for hydration status assessment.


Assuntos
Técnicas Biossensoriais , Eletrólitos , Suor , Suor/química , Humanos , Técnicas Biossensoriais/instrumentação , Eletrólitos/química , Dispositivos Eletrônicos Vestíveis , Desenho de Equipamento , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação
3.
Eur J Appl Physiol ; 124(8): 2451-2459, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38551682

RESUMO

PURPOSE: The rising frequency of extreme heat events poses an escalating threat of heat-related illnesses and fatalities, placing an additional strain on global healthcare systems. Whether the risk of heat-related issues is sex specific, particularly among the elderly, remains uncertain. METHODS: 16 men and 15 women of similar age (69 ± 5 years) were exposed to an air temperature of 39.1 ± 0.3 °C and a relative humidity (RH) of 25.1 ± 1.9%, during 20 min of seated rest and at least 40 min of low-intensity (10 W) cycling exercise. RH was gradually increased by 2% every 5 min starting at minute 30. We measured sweat rate, heart rate, thermal sensation, and the rise in gastrointestinal temperature (Tgi) and skin temperature (Tsk). RESULTS: Tgi consistently increased from minute 30 to 60, with no significant difference between females and males (0.012 ± 0.004 °C/min vs. 0.011 ± 0.005 °C/min; p = 0.64). Similarly, Tsk increase did not differ between females and males (0.044 ± 0.007 °C/min vs. 0.038 ± 0.011 °C/min; p = 0.07). Females exhibited lower sweat rates than males (0.29 ± 0.06 vs. 0.45 ± 0.14 mg/m2/min; p < 0.001) in particular at relative humidities exceeding 30%. No sex differences in heart rate and thermal sensation were observed. CONCLUSION: Elderly females exhibit significantly lower sweat rates than their male counterparts during low-intensity exercise at ambient temperatures of 39 °C when humidity exceeds 30%. However, both elderly males and females demonstrate a comparable rise in core temperature, skin temperature, and mean body temperature, indicating similar health-related risks associated with heat exposure.


Assuntos
Exercício Físico , Temperatura Alta , Sudorese , Humanos , Masculino , Feminino , Idoso , Exercício Físico/fisiologia , Sudorese/fisiologia , Frequência Cardíaca/fisiologia , Temperatura Cutânea/fisiologia , Regulação da Temperatura Corporal/fisiologia , Fatores Sexuais , Resposta ao Choque Térmico/fisiologia , Temperatura Corporal/fisiologia , Caracteres Sexuais
4.
J Basic Clin Physiol Pharmacol ; 35(1-2): 79-84, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38468505

RESUMO

OBJECTIVE: The objective of our study was to assess the impact of heat stress on hydration and cognition among outdoor workers in hot environment. METHODS: Area heat stress assessments were measured using Quest Temp WBGT monitor. Sweat rate for dehydration and reaction time for acute cognitive processing were recorded using standard procedures. RESULTS: Heat stress measurements ranged from 23.8 °C - 42 °C. More than 50 % of the workers had high sweat rate (>1.2 L/h) when exposed to high environmental temperatures. Positive correlation was obtained between WBGT, sweat rate and reaction time which indicates that hyperthermia has an impact on neural network processing. Heart rate and reaction time also increased with rise in WBGT and heavy physical activity. CONCLUSIONS: There was impairment of cognitive functions (reaction time) under heat stress conditions. Hence, reaction time can be used to assess the short-term impact of heat stress on neural modulation and will help to plan effective intervention strategies to reduce morbidity and mortality among workers.


Assuntos
Transtornos de Estresse por Calor , Exposição Ocupacional , Humanos , Temperatura Alta , Exposição Ocupacional/efeitos adversos , Temperatura , Resposta ao Choque Térmico , Índia
5.
Nutrients ; 16(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38542815

RESUMO

Exercise can disrupt the fluid balance, hindering performance and athlete health. Limited data exist on fluid balance responses in varying climates, sexes, and ages. This study aimed to measure and compare fluid balance and urine values among elite soccer players during training at high and low temperatures, examining the differences between sexes, playing positions, and competitive levels within men's soccer. During the 2022-2023 competitive season, a descriptive observational study was conducted on 87 soccer players from an elite Spanish soccer team. The study found that none of the groups exceeded weight loss values of 1.5% of their body mass. Additionally, the soccer players studied experienced higher weight loss, fluid intake, and a higher sweat rate (SR) during summer training compared to winter training. During the summer, male U23-21 soccer players exhibited higher levels of weight loss, fluid intake, and a higher SR compared to female soccer players or the U19-17 male category. No significant differences were found between playing positions. In conclusion, differences in the fluid balance were observed based on the climatic conditions, competitive level, and sex.


Assuntos
Futebol , Humanos , Masculino , Feminino , Futebol/fisiologia , Equilíbrio Hidroeletrolítico/fisiologia , Suor , Sudorese , Redução de Peso
6.
Medicina (Kaunas) ; 60(1)2024 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-38256373

RESUMO

Background and Objective: Dehydration and hyperhydration impact athletes' performance. Exploring the fluid balance concerning body composition might help estimate individual hydration requirements. This area of research, particularly regarding sodium losses, has been relatively understudied. We evaluated the sweat rate (SR), sweat sodium losses, and their relationship with body composition in professional soccer players in Cali, Colombia. Materials and Methods: Thirty-two male players, aged 24.3 (±5.2) years, from the Colombian main soccer league, underwent high-intensity training at 32 °C (with a relative humidity of 79%). The outcome variables included SR, calculated using weight loss and fluid intake; forearm sweat sodium concentration (FSCC), measured through the direct ion-selective electrode method; and estimated the predicted whole sweat sodium loss (PWSSL) in mmol. Predictor variables (body mass, fat, and muscle masses) were estimated using the Deborah Kerr anthropometry method. The association between predictors and outcomes was assessed using linear regression. Results: The mean FSCC, PWSSL, and SR were 26.7 ± 11.3 mmol/L, 43 ± 15.9 mmol/L, and 1.7 ± 0.5 L/h, respectively. Body mass positively predicted FSCC in unadjusted and age/fat-mass-adjusted models [Beta 1.28, 95% confidence interval (CI) 0.39-2.18, p = 0.006], and continued related to FSCC after adjustment for muscle mass with marginal significance [Beta 0.85, 95% CI -0.02 to 1.73, p = 0.056]. Muscle mass was associated with the PWSSL in unadjusted and age/fat-mass-adjusted models [Beta 2.42, 95% CI 0.58-4.26, p = 0.012] and sustained an association with marginal statistical significance after adjustment for body mass [Beta 1.86, 95% CI -0.35 to 4.09, p = 0.097]. Conclusions: Under hot tropical weather conditions, FSCC was relatively low among the players. Body mass was better associated with the FSSC, and muscle mass better related to the PWSSL. Body and muscle masses could be regarded as potential factors to be explored in the estimation of individual sodium needs. However, further studies are required to validate and contrast our findings.


Assuntos
Futebol , Suor , Humanos , Masculino , Colômbia , Composição Corporal , Antebraço
7.
Eur J Appl Physiol ; 124(1): 317-327, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37505231

RESUMO

PURPOSE: Menthol is known to elicit opposing thermoregulatory and perceptual alterations during intense exercise. The current purpose was to determine the thermoregulatory and perceptual effects of topical menthol application prior to walking in the heat. METHODS: Twelve participants walked (1.6 m s-1, 5% grade) for 30 min in the heat (38 °C, 60% relative humidity) with either a 4% menthol or control gel on the upper (shoulder to wrist) and lower (mid-thigh to ankle) limbs. Skin blood flow (SkBF), sweat (rate, composition), skin conductivity, heart rate, temperature (skin, core), and thermal perception were measured prior to and during exercise. RESULTS: Skin conductivity expressed as time to 10, 20, 30, and 40 µS was delayed due to menthol (559 ± 251, 770 ± 292, 1109 ± 301, 1299 ± 335 s, respectively) compared to the control (515 ± 260, 735 ± 256, 935 ± 300, 1148 ± 298 s, respectively, p = 0.048). Sweat rate relative to body surface area was lower due to menthol (0.55 ± 0.16 L h-1 m(2)-1) than the control (0.64 ± 0.16 L h-1 m(2)-1, p = 0.049). Core temperature did not differ at baseline between the menthol (37.4 ± 0.3 °C) and control (37.3 ± 0.4 °C, p = 0.298) but was higher at 10, 20, and 30 min due to menthol (37.5 ± 0.3, 37.7 ± 0.2, 38.1 ± 0.3 °C, respectively) compared to the control (37.3 ± 0.4, 37.4 ± 0.3, 37.7 ± 0.3 °C, respectively, p < 0.05). The largest rise in core temperature from baseline was at 30 min during menthol (0.7 ± 0.3 °C) compared to the control (0.4 ± 0.2 °C, p = 0.004). Overall, the menthol treatment was perceived cooler, reaching "slightly warm" whereas the control treatment reached "warm" (p < 0.001). CONCLUSION: Menthol application to the limbs impairs whole-body thermoregulation while walking in the heat despite perceiving the environment as cooler.


Assuntos
Temperatura Alta , Mentol , Humanos , Mentol/farmacologia , Regulação da Temperatura Corporal/fisiologia , Sudorese , Temperatura Cutânea , Caminhada , Percepção/fisiologia
8.
Adv Sci (Weinh) ; 11(10): e2306023, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38133495

RESUMO

The erratic, intermittent, and unpredictable nature of sweat production, resulting from physiological or psychological fluctuations, poses intricacies to consistently and accurately sample and evaluate sweat biomarkers. Skin-interfaced microfluidic devices that rely on colorimetric mechanisms for semi-quantitative detection are particularly susceptible to these inaccuracies due to variations in sweat secretion rate or instantaneous volume. This work introduces a skin-interfaced colorimetric bifluidic sweat device with two synchronous channels to quantify sweat rate and biomarkers in real-time, even during uncertain sweat activities. In the proposed bifluidic-distance metric approach, with one channel to measure sweat rate and quantify collected sweat volume, the other channel can provide an accurate analysis of the biomarkers based on the collected sweat volume. The closed channel design also reduces evaporation and resists contamination from the external environment. The feasibility of the device is highlighted in a proof-of-the-concept demonstration to analyze sweat chloride for evaluating hydration status and sweat glucose for assessing glucose levels. The low-cost yet highly accurate device provides opportunities for clinical sweat analysis and disease screening in remote and low-resource settings. The developed device platform can be facilely adapted for the other biomarkers when corresponding colorimetric reagents are exploited.


Assuntos
Pele , Suor , Suor/química , Pele/química , Biomarcadores/análise , Dispositivos Lab-On-A-Chip , Glucose/análise
9.
ACS Sens ; 8(11): 4407-4416, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37953512

RESUMO

Early diagnosis of skin barrier dysfunction helps provide timely preventive care against diseases such as atopic dermatitis, psoriasis, food allergies, and other atopic skin disorders. Skin barrier function is commonly evaluated by measuring the transepidermal water loss (TEWL) through stratum corneum due to its noninvasive characteristics. However, existing commercial TEWL devices are significantly affected by many factors, such as ambient temperature, humidity, air flow, water accumulation, initial water contents on the skin surface, bulky sizes, high costs, and requirements for well-controlled environments. Here, we developed a wearable closed-chamber hygrometer-based TEWL device (Wearable Analytical Skin Probe, WASP) and the related algorithm for accurate and continuous monitoring of skin water vapor flux. The WASP uses short dry air purges to dry the skin surface and chamber before each water vapor flux measurement. Its design ensures a highly controlled local environment, such as consistent initial dry conditions for the skin surface and the chamber. We further applied WASP to measure the water vapor flux from six different locations of a small group of human participants. It is found that the WASP can not only measure and distinguish between insensible sweating (i.e., TEWL) and sensible sweating (i.e., thermal sweating) but also track skin dehydration-rehydration cycles. Comparisons with a commercial TEWL device, AquaFlux, show that the results obtained by both devices agree well. The WASP will be broadly applicable to clinical, cosmetic, and biomedical research.


Assuntos
Vapor , Perda Insensível de Água , Humanos , Pele , Epiderme , Umidade
10.
Biosens Bioelectron ; 237: 115504, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37406481

RESUMO

Epidermal microfluidic devices are continuously being developed for efficient sweat collection and sweat rate detection. However, most microfluidic designs ignore the use of airtight/adhesive substrate will block the natural perspiration of the covered sweat pores, which will seriously affect normal sweat production and long-term wearable comfort. Herein, we present a Janus textile-embedded microfluidic sensor platform with high breathability and directional sweat permeability for synchronous sweat rate and total electrolyte concentration detection. The device consists of a hollowed-out serpentine microchannel with interdigital electrodes and Janus textile. The dual-mode signal of the sweat rate (0.2-4.0 µL min-1) and total ionic charge concentration (10-200 mmol L-1) can be obtained synchronously by decoupling conductance step signals generated when sweat flows through alternating interdigitated spokes at equal intervals in the microchannel. Meanwhile, the hollowed-out microchannel structure significantly reduces the coverage area of the sensor on the skin, and the Janus textile-embedded device ensures a comfortable skin/device interface (fewer sweat pores are blocked) and improves breathability (503.15 g m-2 d-1) and sweat permeability (directional liquid transportation) during long-term monitoring. This device is washable and reusable, which shows the potential to integrate with clothing and smart textile, and thus facilitate the practicality of wearable sweat sensors for personalized healthcare.


Assuntos
Técnicas Biossensoriais , Suor , Suor/química , Microfluídica , Eletrólitos , Têxteis
11.
Eur J Appl Physiol ; 123(10): 2225-2237, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37256293

RESUMO

PURPOSE: This study examined the thermoregulatory response and ergogenic effects of ice slurry (ICE) ingestion in hot environments with high and low relative humidity (RH). METHODS: Eight males completed four trials in a crossover manner in dry (DRY: 34.7 ± 0.2 °C, 38 ± 2%RH) and humid heat (HUM: 34.8 °C ± 0.2 °C, 80 ± 1%RH). They ingested 8.0 g·kg-1 of ICE (0.0 °C) or 37.5 °C water (CON) during 30 min before exercise, and three aliquots (3.2 g·kg-1) of ICE or CON during 45-min cycling at 50%[Formula: see text]O2peak, followed by cycling to exhaustion at 80%[Formula: see text]O2peak (TTE). Body core temperature (Tcore), mean skin temperature (Tsk), heart rate (HR), thermal comfort, thermal sensation and rating of perceived exertion (RPE) were measured. RESULTS: Relative to CON, ICE improved TTE by 76.5 ± 96.5% in HUM and 21.3 ± 44.9% in DRY (p = 0.044). End-exercise Tcore was lower in ICE versus CON in DRY (37.8 ± 0.4 °C versus 38.1 ± 0.3 °C, p = 0.005) and HUM (38.8 ± 0.4 °C versus 39.3 ± 0.6 °C, p = 0.004). ICE decreased HR, heat storage and heat strain index only in DRY (p < 0.001-0.018). ICE improved thermal sensation and comfort in DRY and HUM (p < 0.001-0.011), attenuated RPE in HUM (p = 0.012) but not in DRY (p = 0.065). CONCLUSION: ICE tended to benefit performance in humid heat more than in dry heat. This is likely due to the reduced extent of hyperthermia in dry heat and the relative importance of sensory inputs in mediating exercise capacity.


Assuntos
Regulação da Temperatura Corporal , Temperatura Alta , Masculino , Humanos , Regulação da Temperatura Corporal/fisiologia , Temperatura Cutânea , Exercício Físico/fisiologia , Ingestão de Alimentos , Temperatura Corporal/fisiologia
12.
Front Physiol ; 14: 1125969, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37113693

RESUMO

Background: An elevated core temperature (Tcore) increases the risk of performance impairments and heat-related illness. Internal cooling (IC) has the potential to lower Tcore when exercising in the heat. The aim of the review was to systematically analyze the effects of IC on performance, physiological, and perceptional parameters. Methods: A systematic literature search was performed in the PubMed database on 17 December 2021. Intervention studies were included assessing the effects of IC on performance, physiological, or perceptional outcomes. Data extraction and quality assessment were conducted for the included literature. The standardized mean differences (SMD) and 95% Confidence Intervals (CI) were calculated using the inverse-variance method and a random-effects model. Results: 47 intervention studies involving 486 active subjects (13.7% female; mean age 20-42 years) were included in the meta-analysis. IC resulted in significant positive effects on time to exhaustion [SMD (95% CI) 0.40 (0.13; 0.67), p < 0.01]. IC significantly reduced Tcore [-0.19 (22120.34; -0.05), p < 0.05], sweat rate [-0.20 (-0.34; -0.06), p < 0.01], thermal sensation [-0.17 (-0.33; -0.01), p < 0.05], whereas no effects were found on skin temperature, blood lactate, and thermal comfort (p > 0.05). IC resulted in a borderline significant reduction in time trial performance [0.31 (-0.60; -0.02), p = 0.06], heart rate [-0.13 (-0.27; 0.01), p = 0.06], rate of perceived exertion [-0.16 (-0.31; -0.00), p = 0.05] and borderline increased mean power output [0.22 (0.00; 0.44), p = 0.05]. Discussion: IC has the potential to affect endurance performance and selected physiological and perceptional parameters positively. However, its effectiveness depends on the method used and the time point of administration. Future research should confirm the laboratory-based results in the field setting and involve non-endurance activities and female athletes. Systematic review registration: https://www.crd.york.ac.uk/PROSPERO/, identifier: CRD42022336623.

13.
Nutrients ; 15(7)2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-37049589

RESUMO

Elite squash players are reported to train indoors at high volumes and intensities throughout a microcycle. This may increase hydration demands, with hypohydration potentially impairing many key performance indicators which characterise elite squash performance. Consequently, the main aim of this study was to quantify the sweat rates and sweat [Na+] of elite squash players throughout a training session, alongside their hydration practices. Fourteen (males = seven; females = seven) elite or world class squash player's fluid balance, sweat [Na+] and hydration practices were calculated throughout a training session in moderate environmental conditions (20 ± 0.4 °C; 40.6 ± 1% RH). Rehydration practices were also quantified post-session until the players' next training session, with some training the same day and some training the following day. Players had a mean fluid balance of -1.22 ± 1.22% throughout the session. Players had a mean sweat rate of 1.11 ± 0.56 L·h-1, with there being a significant difference between male and female players (p < 0.05), and a mean sweat (Na+) of 46 ± 12 mmol·L-1. Players training the following day were able to replace fluid and sodium losses, whereas players training again on the same day were not. These data suggest the variability in players hydration demands and highlight the need to individualise hydration strategies, as well as training prescription, to ensure players with high hydration demands have ample time to optimally rehydrate.


Assuntos
Sódio , Equilíbrio Hidroeletrolítico , Masculino , Humanos , Feminino , Sudorese , Suor , Hidratação , Desidratação/prevenção & controle , Ingestão de Líquidos
14.
Sensors (Basel) ; 23(7)2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-37050438

RESUMO

The relationship between the onset of sweating (OS) and sweat lactate threshold (sLT) assessed using a novel sweat lactate sensor remains unclear. We aimed to investigate the implications of the OS on the sLT. Forty healthy men performed an incremental cycling test. We monitored the sweat lactate, blood lactate, and local sweating rates to determine the sLT, blood LT (bLT), and OS. We defined participants with the OS during the warm-up just before the incremental test as the early perspiration (EP) group and the others as the regular perspiration (RP) group. Pearson's correlation coefficient analysis revealed that the OS was poorly correlated with the sLT, particularly in the EP group (EP group, r = 0.12; RP group, r = 0.56). Conversely, even in the EP group, the sLT was strongly correlated with the bLT (r = 0.74); this was also the case in the RP group (r = 0.61). Bland-Altman plots showed no bias between the mean sLT and bLT (mean difference: 19.3 s). Finally, in five cases with a later OS than bLT, the sLT tended to deviate from the bLT (mean difference, 106.8 s). The sLT is a noninvasive and continuous alternative to the bLT, independent of an early OS, although a late OS may negatively affect the sLT.


Assuntos
Suor , Sudorese , Masculino , Humanos , Ácido Láctico , Ciclismo
15.
J Therm Biol ; 113: 103535, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37055138

RESUMO

PURPOSE: Determine if topical capsaicin, a transient receptor potential vanilloid heat thermoreceptor activator, alters thermoregulation and perception when applied topically prior to thermal exercise. METHODS: Twelve subjects completed 2 treatments. Subjects walked (1.6 m s-1, 5% grade) for 30 min in the heat (38 °C, 60% relative humidity) with either a capsaicin (0.025% capsaicin) or control cream applied to the upper (shoulder to wrist) and lower (mid-thigh to ankle) limbs covering ∼50% body surface area. Skin blood flow (SkBF), sweat (rate, composition), heart rate, temperature (skin, core), and perceived thermal sensation were measured prior to and during exercise. RESULTS: The relative change in SkBF was not different between treatments at any time point (p = 0.284). There were no differences in sweat rate between the capsaicin (1.23 ± 0.37 L h-1) and control (1.43 ± 0.43 L h-1, p = 0.122). There were no differences in heart rate between the capsaicin (122 ± 38 beats·min-1) and control (125 ± 39 beats·min-1, p = 0.431). There were also no differences in weighted surface (p = 0.976) or body temperatures (p = 0.855) between the capsaicin (36.0 ± 1.7 °C, 37.0 ± 0.8 °C, respectively) and control (36.0 ± 1.6 °C, 36.9 ± 0.8 °C, respectively). The capsaicin treatment was not perceived as hotter than the control treatment until minute 30 of exercise (2.8 ± 0.4, 2.5 ± 0.5, respectively, p = 0.038) CONCLUSIONS: Topical capsaicin application does not alter whole-body thermoregulation during acute exercise in the heat despite perceiving the treatment as hotter late in exercise.


Assuntos
Capsaicina , Temperatura Alta , Humanos , Capsaicina/farmacologia , Temperatura Cutânea , Regulação da Temperatura Corporal/fisiologia , Sudorese , Temperatura Corporal/fisiologia , Exercício Físico/fisiologia , Percepção
16.
Eur J Appl Physiol ; 123(8): 1709-1726, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37005962

RESUMO

PURPOSE: This study examined physiological and perceptual parameters related to cold-induced vasodilation (CIVD) in the fingers and toes of people with paraplegia and compared them with responses observed in able-bodied individuals. METHODS: Seven participants with paraplegia and seven able-bodied individuals participated in a randomized matched-controlled study involving left-hand and -foot immersion in cold water (8 ± 1 °C) for 40 min during exposure to cool (16 ± 1 °C), thermoneutral (23 ± 1 °C), and hot (34 ± 1 °C) ambient conditions. RESULTS: Similar CIVD occurrence was observed in the fingers in the two groups. In toes, three of the seven participants with paraplegia revealed CIVDs: one in cool, two in thermoneutral, and three in hot conditions. No able-bodied participants revealed CIVDs in cool and thermoneutral conditions, while four revealed CIVDs in hot conditions. The toe CIVDs of paraplegic participants were counterintuitive in several respects: they were more frequent in cool and thermoneutral conditions (compared to the able-bodied participants), emerged in these conditions despite lower core and skin temperatures of these participants, and were evident only in cases of thoracic level lesions (instead of lesions at lower spinal levels). CONCLUSION: Our findings demonstrated considerable inter-individual variability in CIVD responses in both the paraplegic and able-bodied groups. While we observed vasodilatory responses in the toes of participants with paraplegia that technically fulfilled the criteria for CIVD, it is unlikely that they reflect the CIVD phenomenon observed in able-bodied individuals. Taken together, our findings favor the contribution of central over peripheral factors in relation to the origin and/or control of CIVD.


Assuntos
Hipotensão , Vasodilatação , Humanos , Vasodilatação/fisiologia , Dedos do Pé/fisiologia , Dedos/fisiologia , Temperatura Baixa , Temperatura Cutânea , Paraplegia
17.
J Sports Sci ; 41(1): 1-7, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37002685

RESUMO

Our aim was to characterize fluid intake during outdoor team sport training and use generalized additive models to quantify interactions with the environment and performance. Fluid intake, body mass (BM) and internal/external training load data were recorded for male rugby union (n = 19) and soccer (n = 19) athletes before/after field training sessions throughout an 11-week preseason (357 observations). Running performance (GPS) and environmental conditions were recorded each session and generalized additive models were applied in the analysis of data. Mean body mass loss throughout all training sessions was -1.11 ± 0.63 kg (~1.3%) compared with a mean fluid intake at each session of 958 ± 476 mL during the experimental period. For sessions >110 min, when fluid intake reached ~10-19 mL·kg-1 BM the total distance increased (7.47 to 8.06 km, 7.6%; P = 0.049). Fluid intake above ~10 mL·kg-1 BM was associated with a 4.1% increase in high-speed running distance (P < 0.0001). Most outdoor team sport athletes fail to match fluid loss during training, and fluid intake is a strong predictor of running performance. Improved hydration practices during training should be beneficial and we provide a practical ingestion range to promote improved exercise capacity in outdoor team sport training sessions.


Assuntos
Desempenho Atlético , Futebol , Humanos , Masculino , Esportes de Equipe , Estações do Ano , Ingestão de Líquidos , Desidratação/prevenção & controle
18.
Nano Lett ; 23(4): 1252-1260, 2023 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-36584409

RESUMO

Although flexible humidity sensors are essential for human health monitoring, it is still challenging to achieve high sensitivity and easy disposal with simple, low-cost fabrication processes. This study presents the design and fabrication of highly reliable hand-drawn interdigital electrodes from pencil-on-paper treated with NaCl solution for highly sensitive hydration sensors working over a wide range of relative humidity (RH) levels from 5.6% to 90%. The applications of the resulting flexible humidity sensor go beyond the monitoring of respiratory rate and proximity to characterizations of human skin types and evaluations of skin barrier functions through insensible sweat measurements. The sensor array can also be integrated with a diaper to result in smart diapers to alert for an early diaper change. The design and fabrication strategies presented in this work could also be leveraged for the development of wearable, self-powered, and recyclable sensors and actuators in the future.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Cloreto de Sódio , Umidade , Pele , Suor
19.
J Therm Biol ; 109: 103325, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36195391

RESUMO

It is well known that there is a high concentration of lactate in sweat. Interest in measuring sweat lactate has arisen from its potential role in several clinical and sport performance applications. However, the effect of heat acclimation on sweat lactate concentration is still under debate. This is partly because sweat lactate concentration is greatly affected by sweat rate, which is known to increase during heat acclimation. Thus, to better understand this issue it is necessary to account for sweat rate - which has not been done previously in the literature. Therefore, the purpose of the current study was to determine the effect of heat acclimation on the relationship between sweat rate vs. sweat lactate concentration. Six subjects completed a 7-day heat acclimation protocol. The daily 2-h exercise bout was split into three 40-min intervals with exercise intensity increasing with each successive interval. This was done to induce three different sweat rates to determine the sweat rate vs. sweat lactate concentration relationship before and after heat acclimation for each participant. A 2 (heat acclimation) x 3 (sweat rate) repeated measures ANOVA was conducted to determine statistical significance. There was a significant (p < 0.05) decrease in the grand mean sweat lactate concentration over the course of seven days of heat acclimation from 17.0 ± 5.0 to 11.3 ± 1.1 mmol/L (p < 0.05). A significant (p < 0.05) heat acclimation x sweat rate ordinal interaction was also found. The results of the current study show that heat acclimation significantly decreases the sweat lactate concentration. In addition, there was a significant ordinal interaction which suggests that the impact of sweat rate on sweat lactate concentration is decreased following heat acclimation.


Assuntos
Temperatura Alta , Suor , Aclimatação , Humanos , Ácido Láctico , Sudorese
20.
Biology (Basel) ; 11(7)2022 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-36101432

RESUMO

BACKGROUND: Cold-induced vasodilation (CIVD) is a phenomenon that refers to a paradoxical increase in finger temperature that sometimes occurs during cold exposure. The aim of this study was to compare CIVD responses between women and men, during exposure to different environmental conditions. METHODS: Seven men and seven women participated in a matched controlled study consisting of a familiarization protocol followed by three experimental sessions (cool (10.8 °C WBGT), thermoneutral (17.2 °C WBGT), and hot (27.2 °C WBGT)). In each session, participants were asked to immerse their left hand and foot in warm water (35 ± 1 °C) for five minutes. Thereafter, the left hand and foot were immersed in cold water (8 ± 1 °C) for 40 min. After that, the left hand and foot were removed from the water and participants remained seated for five minutes. RESULTS: For a matched thermal stress, women experienced an elevated cardiovascular strain (heart rate and in some cases mean arterial pressure) and higher frequency of CIVD reactions (men: 31 vs. women: 60) in comparison to their male counterparts. CONCLUSIONS: The present study demonstrated that women experienced elevated cardiovascular strain and higher frequency of CIVD reactions, particularly in the toes, compared to their male counterparts during cold-water immersion.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA