Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Neurospine ; 21(3): 973-983, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39363473

RESUMO

OBJECTIVE: Biportal endoscopic transforaminal lumbar interbody fusion (BE-TLIF) is an emerging, minimally invasive technique performed under biportal endoscopic guidance. However, concerns regarding cage subsidence and sufficient fusion during BE-TLIF necessitate careful selection of an appropriate interbody cage to improve surgical outcomes. This study compared the fusion rate, subsidence, and other radiographic parameters according to the material and size of the cages used in BE-TLIF. METHODS: In this retrospective cohort study, patients who underwent single-segment BE-TLIF between April 2019 and February 2023 were divided into 3 groups: group A, regular-sized three-dimensionally (3D)-printed titanium cages; group B, regular-sized polyetheretherketone cages; and group C, large-sized 3D-printed titanium cages. Radiographic parameters, including lumbar lordosis, segmental lordosis, anterior and posterior disc heights, disc angle, and foraminal height, were measured before and after surgery. The fusion rate and severity of cage subsidence were compared between the groups. RESULTS: No significant differences were noted in the demographic data or radiographic parameters between the groups. The fusion rate on 1-year postoperative computed tomography was comparable between the groups. The cage subsidence rate was significantly lower in group C than in group A (41.9% vs. 16.7%, p=0.044). The severity of cage subsidence was significantly lower in group C (0.93±0.83) than in groups A (2.20±1.84, p=0.004) and B (1.79±1.47, p=0.048). CONCLUSION: Cage materials did not affect the 1-year postoperative outcomes of BE-TLIF; however, subsidence was markedly reduced in large cages. Larger cages may provide more stable postoperative segments.

2.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 535-541, 2024 May 15.
Artigo em Chinês | MEDLINE | ID: mdl-38752238

RESUMO

Objective: To evaluate the effectiveness of using titanium alloy trabecular bone three-dimensional (3D) printed artificial vertebral body in treating cervical ossification of the posterior longitudinal ligament (OPLL). Methods: A retrospective analysis was conducted on clinical data from 45 patients with cervical OPLL admitted between September 2019 and August 2021 and meeting the selection criteria. All patients underwent anterior cervical corpectomy and decompression, interbody bone graft fusion, and titanium plate internal fixation. During operation, 21 patients in the study group received titanium alloy trabecular bone 3D printed artificial vertebral bodies, while 24 patients in the control group received titanium cages. There was no significant difference in baseline data such as gender, age, disease duration, affected segments, or preoperative pain visual analogue scale (VAS) score, Japanese Orthopaedic Association (JOA) score, Neck Disability Index (NDI), vertebral height, and C 2-7Cobb angle ( P>0.05). Operation time, intraoperative blood loss, and occurrence of complications were recorded for both groups. Preoperatively and at 3 and 12 months postoperatively, the functionality and symptom relief were assessed using JOA scores, VAS scores, and NDI evaluations. The vertebral height and C 2-7 Cobb angle were detected by imaging examinations and the implant subsidence and intervertebral fusion were observed. Results: The operation time and incidence of complications were significantly lower in the study group than in the control group ( P<0.05), while the difference in intraoperative blood loss between the two groups was not significant ( P>0.05). All patients were followed up 12-18 months, with the follow-up time of (14.28±4.34) months in the study group and (15.23±3.54) months in the control group, showing no significant difference ( t=0.809, P=0.423). The JOA score, VAS score, and NDI of the two groups improved after operation, and further improved at 12 months compared to 3 months, with significant differences ( P<0.05). At each time point, the study group exhibited significantly higher JOA scores and improvement rate compared to the control group ( P<0.05); but there was no significantly difference in VAS score and NDI between the two groups ( P>0.05). Imaging re-examination showed that the vertebral height and C 2-7Cobb angle of the two groups significantly increased at 3 and 12 months after operation ( P<0.05), and there was no significant difference between 3 and 12 months after operation ( P>0.05). At each time point, the vertebral height and C 2-7Cobb angle of the study group were significantly higher than those of the control group ( P<0.05), and the implant subsidence rate was significantly lower than that of the control group ( P<0.05). However, there was no significant difference in intervertebral fusion rate between the two groups ( P>0.05). Conclusion: Compared to traditional titanium cages, the use of titanium alloy trabecular bone 3D-printed artificial vertebral bodies for treating cervical OPLL results in shorter operative time, fewer postoperative complications, and lower implant subsidence rates, making it superior in vertebral reconstruction.


Assuntos
Ligas , Vértebras Cervicais , Ossificação do Ligamento Longitudinal Posterior , Impressão Tridimensional , Fusão Vertebral , Titânio , Humanos , Ossificação do Ligamento Longitudinal Posterior/cirurgia , Vértebras Cervicais/cirurgia , Estudos Retrospectivos , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Descompressão Cirúrgica/métodos , Osso Esponjoso , Resultado do Tratamento , Corpo Vertebral/cirurgia , Feminino , Masculino , Placas Ósseas , Pessoa de Meia-Idade
3.
Injury ; 55(2): 111164, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37923678

RESUMO

PURPOSE: To investigate the fusion construct properties, construct length, intervertebral prosthesis (IVP) selection, bone grafting methods, complications management, and follow-up outcomes of spondylodiscitis fusion. METHOD: This case series was conducted in Al-Zahra University referral hospital from March 2016 to November 2021. All the surgery-eligible patients were enrolled. Those who did not participate or failed the neurosurgical intervention were excluded. A unified neurosurgical protocol was defined. After operation and follow-up, all variables were documented. IBM SPSS v.26 was used for data analysis. P-value ≤ 0.05 was considered significant. RESULT: Ninety-two patients were reviewed in the final analysis with 65.2 % males. The mean age was 55.07 ± 14.22 years old. The most frequent level of pathology and surgery was the lumbar spine (48.9 %). Short and long constructs were almost equally used (57.6 and 42.4 %, respectively). Bone graft mixture was the dominant IVP (75 %). The most frequent persistent postoperative symptom was back pain (55.4 %), while the neurological deficits resolution rate was 76.7 %. The fusion rate was 92.3 %. Proximal junctional kyphosis incidence was 16.3 % and had a significant association with on-admission neurological symptoms, thoracic and thoracolumbar junction involvements (p < 0.05). Follow-up Oswestry disability index scores showed 44.6 % of the patients had mild or no functional disabilities. Advanced age, On-admission deficits, comorbidities, titanium cages, and poor fusion status were associated with poor functional outcomes and higher mortality rates (P < 0.05). CONCLUSION: The introduced neurosurgical protocol could effectively achieve acceptable SD treatment, spine stabilization, and fusion with low long-term surgical complications. Autologous bone graft mixture in comparison to titanium cages showed a higher fusion rate with a lower mortality rate. Patients with older age, neurological symptoms, and comorbidities are expected to experience less favorable clinical outcomes.


Assuntos
Discite , Fusão Vertebral , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Seguimentos , Discite/cirurgia , Titânio , Resultado do Tratamento , Fusão Vertebral/métodos , Vértebras Lombares/cirurgia , Estudos Retrospectivos
4.
World Neurosurg ; 183: 144-156, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38145654

RESUMO

OBJECTIVE: To compare the safety and radiological effectiveness of lumbar interbody fusion with a 3D-printed porous titanium (3D-PPT) cage versus a polyetheretherketone (PEEK) cage for the treatment of lumbar degenerative disease. METHODS: This study was registered at PROSPERO (CRD42023461511). We systematically searched the PubMed, Embase, and Web of Science databases for related studies from inception to September 3, 2023. Review Manager 5.3 was used to conduct this meta-analysis. The reoperation rate, complication rate, fusion rate, and subsidence rate were assessed using relative risk and 95% confidence intervals. RESULTS: Ten articles reporting 9 studies comparing lumbar interbody fusion with 3D-PPT cages versus PEEK cages for the treatment of lumbar degenerative disease were included. The subsidence rate at the 1-year follow-up in the 3D-PPT cage was significantly lower than that in the PEEK cage. The fusion rate in the 3D-PPT cage was significantly higher than that in the PEEK cage at the 6-month follow-up. No significant difference was identified between the 2 groups at the 12-month follow-up. No significant difference was identified between the 2 groups in terms of the complication rate and reoperation rate. There was a trend toward a lower complication rate and reoperation rate with the 3D-PPT cage. CONCLUSIONS: Compared with the PEEK cage, the 3D-PPT cage may be a safer implant. The 3D-PPT cage was associated with a higher fusion rate and lower subsidence rate. The 3D-PPT cage may accelerate the intervertebral fusion process, improve the quality of fusion and prevent the occurrence of subsidence.


Assuntos
Benzofenonas , Degeneração do Disco Intervertebral , Cetonas , Vértebras Lombares , Polietilenoglicóis , Polímeros , Impressão Tridimensional , Fusão Vertebral , Titânio , Humanos , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação , Vértebras Lombares/cirurgia , Degeneração do Disco Intervertebral/cirurgia , Porosidade
5.
J Funct Biomater ; 14(12)2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38132816

RESUMO

3D-printed titanium (Ti) cages present an attractive alternative for addressing issues related to osteoporosis-induced fractures, accidental fractures, and spinal fusion surgery due to disc herniation. These Ti-based bone implants possess superior strength compared to other metals, allowing for versatile applications in orthopedic scenarios. However, when used as standalone solutions, certain considerations may arise, such as interaction with soft tissues. Therefore, to overcome these issues, the combination with hydrogel has been considered. In this study, to impart Ti with regenerative abilities a 3D-printed Ti cage was loaded with gelatin and hyaluronic acid (G-H) to improve the cell attachment ability of the Ti-based bone implants. The void spaces within the mesh structure of the 3D Ti cage were filled with G-H, creating a network of micro-sized pores. The filled G-H acted as the bridge for the cells to migrate toward the large inner pores of the 3D Ti cage. Due to the microporous surface and slow release of gelatin and hyaluronic acid, the biocompatibility of the coated Ti cage was increased with an elevation in osteoconduction as depicted by the up-regulation of bone-related gene expressions. The in vivo implantation in the rabbit femur model showed enhanced bone regeneration due to the coated G-H on the Ti cage compared to the pristine hollow Ti cage. The G-H filled the large holes of the 3D Ti cage that acted as a bridge for the cells to travel inside the implant and aided in the fast regeneration of bone.

6.
JOR Spine ; 6(3): e1268, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37780834

RESUMO

Background: The use of intervertebral cages within the interbody fusion setting is ubiquitous. Synthetic cages are predominantly manufactured using materials such as Ti and PEEK. With the advent of additive manufacturing techniques, it is now possible to spatially vary complex 3D geometric features within interbody devices, enabling the devices to match the stiffness of native tissue and better promote bony integration. To date, the impact of surface porosity of additively manufactured Ti interbody cages on fusion outcomes has not been investigated. Thus, the objective of this work was to determine the effect of implant endplate surface and implant body architecture of additive manufactured lattice structure titanium interbody cages on bony fusion. Methods: Biomechanical, microcomputed tomography, static and dynamic histomorphometry, and histopathology analyses were performed on twelve functional spine units obtained from six sheep randomly allocated to body lattice or surface lattice groups. Results: Nondestructive kinematic testing, microcomputed tomography analysis, and histomorphometry analyses of the functional spine units revealed positive fusion outcomes in both groups. These data revealed similar results in both groups, with the exception of bone-in-contact analysis, which revealed significantly improved bone-in-contact values in the body lattice group compared to the surface lattice group. Conclusion: Both additively manufactured porous titanium cage designs resulted in increased fusion outcomes as compared to PEEK interbody cage designs as illustrated by the nondestructive kinematic motion testing, static and dynamic histomorphometry, microcomputed tomography, and histopathology analyses. While both cages provided for similar functional outcomes, these data suggest boney contact with an interbody cage may be impacted by the nature of implant porosity adjacent to the vertebral endplates.

7.
Injury ; 54(12): 111130, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37890289

RESUMO

INTRODUCTION: The segmental bone defects post open distal femur fracture presents a reconstructive challenge, which often requires extreme solutions. The present study reviewed a new treatment strategy which used a cylindrical titanium mesh cage as an adjunct to the Masquelet technique. METHODS: We retrospectively reviewed a consecutive series of 23 patients treated for segmental bone defects post open distal femur fracture using a titanium mesh cage combined with the Masquelet technique under a 2-staged protocol in our institution from 2017 to 2021. The study group consisted of 13 men and 10 women with an average age of 44.1 years. The surgical debridement was performed with antibiotic polymethylmethacrylate (PMMA) cement spacer implanted into the bone defect combined with cement-wrapped plate stabilization, or antibiotic beads with vacuum sealing drainage (VSD) to cover the wound. The second stage of the Masquelet technique for bone defect repair began at least 4-6 weeks after the first stage, once all signs of possible infection were eliminated. After the cement spacer was removed, the definitive reconstruction was completed with exchange to a cylindrical titanium mesh cage filled with cancellous autograft within the induced membrane. The bone defect with cage was stabilized with a distal femoral Less Invasive Stabilization System (LISS). The radiological and clinical records of the enrolled patients were retrospectively analyzed. RESULTS: The mean follow-up was 38.6 months. The average number of operations before the second stage was 1.3. The mean interval between the two stages was 12.7 weeks. The average length of the defect measured 8.3 cm (ranging from 6.1 to 12.4 cm). All the defects filled with autograft within the cage achieved bony union, with a mean healing time of 8.4 months. At the latest follow-up, the mean knee extension measured 6.2° (ranging from 0° to 20°), and the mean flexion measured 101.8° (ranging from 60° to 120°). Complications included two instances of superficial stitch abscess, which eventually healed. CONCLUSIONS: The use of a titanium cage implanted into an induced membrane in a 2-staged Masquelet protocol could achieve satisfactory clinical outcomes in cases of segmental defects following open distal femur fractures.


Assuntos
Fraturas Femorais Distais , Fraturas do Fêmur , Masculino , Humanos , Feminino , Adulto , Titânio , Estudos Retrospectivos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Antibacterianos/uso terapêutico , Transplante Ósseo/métodos , Resultado do Tratamento
8.
Clin Podiatr Med Surg ; 40(4): 711-724, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37716747

RESUMO

Segmental bone loss of the distal tibia and/or talus presents a challenge to successful reconstruction for the foot and ankle surgeon. When conservative care has been exhausted, multiple surgical treatment options are available including bone transport, bulk allografts, bulk autografts, titanium cages, and external fixation techniques. The primary goals of surgical correction include restoration of limb length as well as a plantigrade, stable lower extremity.


Assuntos
Articulação do Tornozelo , Tálus , Humanos , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Artrodese , Extremidade Inferior , Autoenxertos , Tálus/diagnóstico por imagem , Tálus/cirurgia
9.
World Neurosurg ; 179: e241-e255, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37611804

RESUMO

OBJECTIVE: Transforaminal lumbar interbody fusion (TLIF) is performed worldwide with polyetheretherketone (PEEK) and titanium (Ti) cages for the treatment of degenerative lumbar diseases. The aim of this study was to compare radiologic outcomes between a PEEK and three-dimensional-printed titanium (3DP-Ti) cage after TLIF with >1 year of follow-up. METHODS: A total of 140 patients with degenerative lumbar diseases who underwent TLIF operation were included in this study. Intervertebral disc height and whole lumbar lordosis were measured and evaluated from the preoperative stage to the final follow-up. Subsidence of the cage was indicated if the cage sunk into the adjacent vertebral body or if there was a reduction in height of the fused segment by ≥3 mm during the postoperative follow-up. Migration of the cage was determined as the displacement of the interbody cage by ≥2 mm during the postoperative period. Fusion status was assessed at the 1 year and final follow-up using standard methods. RESULTS: Both disc height and lumbar lordosis were well maintained throughout the study period, and no significant differences were observed between PEEK and 3DP-Ti groups. Both PEEK and 3DP-Ti cages demonstrated low rates of cage subsidence, with no significant difference was noted. A significant cage migration rate was observed in the PEEK group and the revision operation was required for 2 patients. The fusion rate of this study was not found to be statistically significant, although the 3DP-Ti cage was known to have an improved fusion rate than PEEK cage after lumbar interbody fusion. CONCLUSIONS: Radiologic results suggest that the 3DP-Ti cage may be a better interbody cage for TLIF than is the PEEK cage.


Assuntos
Lordose , Fusão Vertebral , Humanos , Titânio , Lordose/diagnóstico por imagem , Lordose/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Fusão Vertebral/métodos , Polietilenoglicóis , Cetonas , Resultado do Tratamento , Estudos Retrospectivos
10.
World Neurosurg ; 2023 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-37356484

RESUMO

OBJECTIVE: Interbody cages for spinal fusions are primarily constructed from polyetheretherketone or titanium compositions. However, these crude macroscopic materials pose limitations for improving the rates of bony fusions. The authors aimed to compare the fusion rates and postoperative complications in patients who underwent 2-level or 3-or 4-level anterior cervical discectomy and fusion (ACDF) performed with the use of a novel biomimetic surface titanium cage. METHODS: A retrospective multicenter study was conducted that included all patients who underwent multilevel ACDF with this cage between January 2017 and April 2021. Patient demographics and procedure-related, radiographic, and postoperative complication data were collected. RESULTS: A total of 124 patients were identified; 69 (55.6%) had a 3-or 4-level fusion and 55 (44.4%) had a 2-level fusion. The demographics of the 2 groups differed significantly only in terms of age (P = 0.01). At 3 months, a significantly higher solid fusion rate was found for 2-level fusions than 3-or 4-level fusions (83.7% vs. 56.3%, P = 0.004); however, significance was lost at 6-months (98.2% vs. 88.4%, respectively; P = 0.08). No patients required posterior supplemental fixation. Transient dysphagia was the only postoperative complication that was significantly increased in the 3-or 4-level fusion group compared to the 2-level group (27.5% vs. 9.1%, P = 0.02). CONCLUSIONS: Radiographic and clinical outcomes were equivalent in 3-or 4-level and 2-level ACDFs in which these biomimetic surface titanium cages were used. Furthermore, the use of this technology led to high fusion rates with no requirement for posterior supplemental fusions.

11.
Eur Spine J ; 32(7): 2533-2540, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37160441

RESUMO

PURPOSE: To report and analyze development trends in the surgical treatment of congenital scoliosis (CS) in a large CS cohort over a 10-year period. METHODS: We retrospectively searched and extracted medical records of CS inpatients receiving posterior instrumented fusion surgery at our institute from January 2010 to December 2019. We analyzed information on demographics and surgical information, including the surgical approach, number of fused segments, use of osteotomy and titanium cage implantation, length of stay, intraoperative blood loss, and rates of complications and readmission. RESULTS: 1207 CS inpatients were included. In the past decade, the proportion of patients younger than 5 years increased from 15.5 to 26.9%. The average number of fused segments decreased from 9.24 to 7.48, and the proportion of patients treated with short-segment fusion increased from 13.4 to 30.3%. The proportion of patients treated with osteotomy and titanium cage implantation increased from 55.65% and 12.03% to 76.5% and 40.22%. The average length of stay and blood loss decreased from 16.5 days and 816.1 ml to 13.5 days and 501.7 ml. The complication and readmission rates also decreased during these ten years. CONCLUSION: During this ten-year period, the surgical treatment of CS at our institute showed trends toward a younger age at fusion, lower number of fused segments, higher rate of osteotomy and titanium cage implantation, reduced blood loss, shorter length of stay and lower rate complications and readmission. These results suggest performing osteotomy combined with titanium cage implantation at an earlier age can achieve fewer fused segments and complications.


Assuntos
Escoliose , Fusão Vertebral , Humanos , Escoliose/etiologia , Resultado do Tratamento , Estudos Retrospectivos , Titânio , Próteses e Implantes , Fusão Vertebral/métodos
12.
Acta Neurochir (Wien) ; 165(6): 1435-1443, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37115323

RESUMO

PURPOSE: The aim of this study was to introduce biportal endoscopic extraforaminal lumbar interbody fusion (BE-EFLIF), which involves insertion of a cage through a more lateral side as compared to the conventional corridor of transforaminal lumbar interbody fusion. We described the advantages and surgical steps of 3D-printed porous titanium cage with large footprints insertion through multi-portal approach, and preliminary results of this technique. METHODS: This retrospective study included 12 consecutive patients who underwent BE-EFLIF for symptomatic single-level lumbar degenerative disease. Clinical outcomes, including a visual analog scale (VAS) for back and leg pain and the Oswestry disability index (ODI), were collected at preoperative months 1 and 3, and 6 months postoperatively. In addition, perioperative data and radiographic parameters were analyzed. RESULTS: The mean patient age, follow-up period, operation time, and volume of surgical drainage were 68.3 ± 8.4 years, 7.6 ± 2.8 months, 188.3 ± 42.4 min, 92.5 ± 49.6 mL, respectively. There were no transfusion cases. All patients showed significant improvement in VAS and ODI postoperatively, and these were maintained for 6 months after surgery (P < 0.001). The anterior and posterior disc heights significantly increased after surgery (P < 0.001), and the cage was ideally positioned in all patients. There were no incidences of early cage subsidence or other complications. CONCLUSIONS: BE-EFLIF using a 3D-printed porous titanium cage with large footprints is a feasible option for minimally invasive lumbar interbody fusion. This technique is expected to reduce the risk of cage subsidence and improve the fusion rate.


Assuntos
Fusão Vertebral , Titânio , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Resultado do Tratamento , Porosidade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fusão Vertebral/métodos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Impressão Tridimensional
13.
Front Surg ; 10: 1096080, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36874465

RESUMO

Background: To assess the clinical and radiographical outcomes of 3-level anterior cervical discectomy and fusion (ACDF) with a 3D-printed titanium cage in treating degenerative cervical spondylosis. Methods: In this study, 25 patients with degenerative cervical spondylosis who underwent 3-level ACDF using a 3D-printed titanium cage from March 2019 to June 2021 were retrospectively enrolled. The patient-reported outcome measures (PROMs) were evaluated by visual analog scale (VAS) for the neck (VAS-neck) and arm pain (VAS-arm), Neck Disability Index (NDI) score, Japanese Orthopedic Association (JOA) score, SF-12 concise health survey, and the Odom criteria. The radiographical parameters, including C2-C7 lordosis, segmental angle, segmental height, and subsidence, were assessed. The mean duration of follow-up was 25.6 months. Results: Bony fusion was achieved in all patients (100%). In three patients (12%) mild dysphagia was observed during the follow-up. The VAS-neck, VAS-arm, NDI score, JOA score, SF-12 score, C2-C7 lordosis, and segmental angle improved noticeably at the latest follow-up. Based on the Odom criteria, 22 patients (88%) reported satisfactory (excellent or good). The mean loss of C2-C7 lordosis and segmental angle between the immediate postoperative and the latest follow-up values were 1.6° ± 0.5° and 1.1° ± 0.5°, respectively. The mean subsidence was 0.9 ± 0.6 mm. Conclusion: In patients with multi-level degenerative cervical spondylosis, 3-level ACDF using the 3D-printed titanium cage can effectively relieve the symptoms, stabilize the spine, and restore segmental height and cervical curvature. It is proven to be a reliable option for patients with 3-level degenerative cervical spondylosis. However, a future comparative study involving a larger population and longer follow-up time may be required to further evaluate the safety, efficacy and outcomes of our preliminary results.

14.
Am J Transl Res ; 15(1): 114-124, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36777855

RESUMO

Three-dimensional (3D) printed titanium (Ti-6Al-4V alloy) cages are widely used for spinal fusion applications. However, the structural design and shape of the cages are a major determinant of the optimal clinical outcome. In this study, we constructed a newly designed 3D-printed helical-shaped titanium cage (HTC) with a flexible body, and compared its healing and fusion efficacy in cervical vertebral defects after corpectomy in rabbits to that of a 3D-printed traditional titanium cage (TTC). We performed radiological examinations 1 and 16 weeks after TTC and HTC implantation. We assessed bone ingrowth in TTC and HTC using micro-computed tomography (micro-CT) and histological staining of tissue sections at 16 weeks. The radiographic data showed that the HTC-implanted group had better restoration of vertebral height than the TTC group, indicating a lower risk of cage subsidence. The micro-CT and histological observations showed that HTC promoted bone regeneration and osseointegration more effectively than TTC. Histomorphometry further revealed significant new bone formation in the HTC group compared to the TTC group. These findings demonstrate that HTC has better healing and bone fusion effects than TTC in cervical vertebral defects in rabbits, indicating its potential clinical value.

15.
Ann R Coll Surg Engl ; 105(4): 378-383, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35950498

RESUMO

BACKGROUND: Cage subsidence after anterior cervical discectomy and fusion (ACDF) surgery has been well documented with rates of up to 40%. Cages fill the void after cervical discectomy and promote fusion. These materials have different biomechanical profiles with differing rates of subsidence. This retrospective cohort study aimed to determine subsidence rates specifically associated with the novel Emerging Implant Technologies (EIT) titanium cage, identify risk factors associated with subsidence, and evaluate whether subsidence affects clinical outcomes. METHODS: ACDF with insertion of stand-alone EIT cage was performed in 39 patients (64 levels) between December 2016 and February 2019 with a median follow-up of 11 months. Patients were classified into two groups; subsidence and non-subsidence, and were compared in terms of the resultant clinical outcomes as well as presence of risk factors. Health-related quality of life (HRQOL) outcomes were assessed using Visual Analogue Scale (VAS) for neck and arm pain, EuroQol 5-Dimension 5-Level (EQ-5D-5L), EuroQol Visual Analogue Scale (EQ VAS) and Neck Disability Index (NDI) scores. RESULTS: Cage subsidence (>3mm) was present in nine patients (23%), which corresponded to ten levels treated (16%). Development of subsidence was not associated with gender (p = 0.12), age (p = 0.27), smoking (p = 0.13), number of treatment levels (p = 0.10) or cage size used (p = 0.34). It had no effect on any of the HRQOL outcomes, namely VAS Neck (p = 0.07), VAS Arms (p = 0.08), EQ-5D-5L (p = 0.36), EQ VAS (p = 0.85) and NDI (p = 0.80). CONCLUSIONS: The EIT cage seems to be associated with lower rates of subsidence compared with other cage types. Cage subsidence was not associated with HRQOL outcomes or risk factors.


Assuntos
Fusão Vertebral , Titânio , Humanos , Estudos Retrospectivos , Qualidade de Vida , Resultado do Tratamento , Vértebras Cervicais/cirurgia , Discotomia/métodos , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos
16.
Global Spine J ; 13(7): 1703-1715, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34558320

RESUMO

STUDY DESIGN: Retrospective cohort study. OBJECTIVE: Substantial variability in both the measurement and classification of subsidence limits the strength of conclusions that can be drawn from previous studies. The purpose of this study was to precisely characterize patterns of cervical cage subsidence utilizing computed tomography (CT) scans, determine risk factors for cervical cage subsidence, and investigate the impact of subsidence on pseudarthrosis rates. METHODS: We performed a retrospective review of patients who underwent one- to three-levels of anterior cervical discectomy and fusion (ACDF) utilizing titanium interbodies with anterior plating between the years 2018 and 2020. Subsidence measurements were performed by two independent reviewers on CT scans obtained 6 months postoperatively. Subsidence was then classified as mild if subsidence into the inferior and superior endplate were both ≤2 mm, moderate if the worst subsidence into the inferior or superior endplate was between 2 to 4 mm, or severe if the worst subsidence into the inferior or superior endplate was ≥4 mm. RESULTS: A total of 51 patients (100 levels) were included in this study. A total of 48 levels demonstrated mild subsidence (≤2 mm), 38 demonstrated moderate subsidence (2-4 mm), and 14 demonstrated severe subsidence (≥4 mm). Risk factors for severe subsidence included male gender, multilevel constructs, greater mean vertebral height loss, increased cage height, lower Taillard index, and lower screw tip to vertebral body height ratio. Severe subsidence was not associated with an increased rate of pseudarthrosis. CONCLUSION: Following ACDF with titanium cervical cages, subsidence is an anticipated postoperative occurrence and is not associated with an increased risk of pseudarthrosis.

17.
Cureus ; 14(8): e28059, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36134104

RESUMO

This case report aimed to identify potential relationships between pathological and radiological assessments of bony fusion after anterior cervical discectomy and fusion (ACDF). ACDF can resolve neurological symptoms related to cervical spondylosis, such as myelopathy and radiculopathy. Intervertebral bony fusion is a key outcome for successful ACDF, often assessed on radiography and computed tomography (CT) images. However, the pathological findings of tissues demonstrating bony fusion after ACDF have not been well studied. This report presents the cases of two female patients, aged 62 and 40 years, who underwent additional ACDFs for recurrent cervical radiculopathy. Findings from CT imaging identified intervertebral calcification in the titanium spacers placed in the first ACDF. In both cases, recurrent compression of nerve roots was observed radiologically. Cervical nerve root block identified habitual symptoms related to recurrent radiculopathy. To resolve the clinical symptoms, additional ACDFs were performed in two cases. In the second ACDF, the titanium cases from the prior ACDF were removed. Histopathological examination of the tissues from the removed cages revealed growth of cartilage tissue. This is the first report concerning the histopathological evaluation of the tissue in titanium spacers placed in ACDF. Completion of intervertebral calcification in titanium spacers placed in ACDF may not signify completion of intervertebral bony fusion after ACDF.

18.
Front Bioeng Biotechnol ; 9: 750246, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35087797

RESUMO

Introduction: 3D printed trussed titanium interbody cages may deliver bone stimulating mechanobiological strains to cells attached at their surface. The exact size and distribution of these strains may depend on patient-specific factors, but the influence of these factors remains unknown. Therefore, this study aimed to determine patient-specific variations in local strain patterns on the surface of a trussed titanium interbody fusion cage. Materials and Methods: Four patients eligible for spinal fusion surgery with the same cage size were selected from a larger database. For these cases, patient-specific finite element models of the lumbar spine including the same trussed titanium cage were made. Functional dynamics of the non-operated lumbar spinal segments, as well as local cage strains and caudal endplate stresses at the operated segment, were evaluated under physiological extension/flexion movement of the lumbar spine. Results: All patient-specific models revealed physiologically realistic functional dynamics of the operated spine. In all patients, approximately 30% of the total cage surface experienced strain values relevant for preserving bone homeostasis and stimulating bone formation. Mean caudal endplate contact pressures varied up to 10 MPa. Both surface strains and endplate contact pressures varied more between loading conditions than between patients. Conclusions: This study demonstrates the applicability of patient-specific finite element models to quantify the impact of patient-specific factors such as bone density, degenerative state of the spine, and spinal curvature on interbody cage loading. In the future, the same framework might be further developed in order to establish a pipeline for interbody cage design optimizations.

19.
Oper Neurosurg (Hagerstown) ; 20(1): 109-118, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33026443

RESUMO

BACKGROUND: Expandable cervical cages have been used successfully to reconstruct the anterior spinal column. OBJECTIVE: To perform clinical and radiological evaluation of vertebral body replacement with an anchored expandable titanium cage in the cervical spine after single-level and 2-level corpectomies. METHODS: Between 2011 and 2017, 40 patients underwent a single-level (N = 32) or 2-level (N = 8) anterior corpectomy and fusion using an anchored expandable vertebral body replacement cage. Clinical and radiological data at admission, postoperatively, and at 3- and 12-mo follow-up were retrospectively analyzed. Clinical assessment was performed via standardized neurological evaluation, Odom score, and McCormick classification. Radiological assessment was performed via evaluation of sagittal profile, postoperative position, fusion, and subsidence rates. RESULTS: Mean last follow-up was 14.8 ± 7 mo. Overall clinical and myelopathy-related improvements were shown directly after operation and at last follow-up. A stable centralized positioning of cages was achieved in 37 patients (93%). A mild ventral (>1.5 mm) malplacement was noted in 3 patients (7%) without clinical consequences. Sagittal alignment and preoperative cervical kyphosis improved significantly (7.8° gain of lordosis) and remained stable. Mean preoperative height of operated segments increased by 10 mm postoperatively and remained stable. Fusion rate in non-neoplastic patients and subsidence rate at last follow-up comprised 87.5% and 17.8%. With exception of 1 patient suffering from severe osteoporosis and cage subsidence, no patient needed additional secondary stabilization. CONCLUSION: Anterior corpectomy and fusion by an expandable anchored titanium cage with anchor screws without additional instrumentation resulted in overall clinical improvement and radiological anterior column support, achieving significant and reliable restoration of the physiological sagittal cervical profile.


Assuntos
Fusão Vertebral , Titânio , Animais , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Corpo Vertebral
20.
J Neurosurg Spine ; 33(6): 796-805, 2020 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-32764175

RESUMO

OBJECTIVE: Nonunion after posterior lumbar interbody fusion (PLIF) is associated with poor long-term outcomes in terms of health-related quality of life. Biomechanical factors in the fusion segment may influence spinal fusion rates. There are no reports on the relationship between intervertebral union and the absorption of autografts or vertebral endplates. Therefore, the purpose of this retrospective study was to evaluate the risk factors of nonunion after PLIF and identify preventive measures. METHODS: The authors analyzed 138 patients who underwent 1-level PLIF between 2016 and 2018 (75 males, 63 females; mean age 67 years; minimum follow-up period 12 months). Lumbar CT images obtained soon after the surgery and at 6 and 12 months of follow-up were examined for the mean total occupancy rate of the autograft, presence of a translucent zone between the autograft and endplate (more than 50% of vertebral diameter), cage subsidence, and screw loosening. Complete intervertebral union was defined as the presence of both upper and lower complete fusion in the center cage regions on coronal and sagittal CT slices at 12 months postoperatively. Patients were classified into either union or nonunion groups. RESULTS: Complete union after PLIF was observed in 62 patients (45%), while nonunion was observed in 76 patients (55%). The mean total occupancy rate of the autograft immediately after the surgery was higher in the union group than in the nonunion group (59% vs 53%; p = 0.046). At 12 months postoperatively, the total occupancy rate of the autograft had decreased by 5.4% in the union group and by 11.9% in the nonunion group (p = 0.020). A translucent zone between the autograft and endplate immediately after the surgery was observed in 14 and 38 patients (23% and 50%) in the union and nonunion groups, respectively (p = 0.001). The nonunion group had a significantly higher proportion of cases with cage subsidence and screw loosening at 12 months postoperatively in comparison to the union group (p = 0.010 and p = 0.009, respectively). CONCLUSIONS: A lower occupancy rate of the autograft and the presence of a translucent zone between the autograft and endplate immediately after the surgery were associated with nonunion at 12 months after PLIF. It may be important to achieve sufficient contact between the autograft and endplate intraoperatively for osseous union enhancement and to avoid excessive absorption of the autograft. The achievement of complete intervertebral union may decrease the incidence of cage subsidence or screw loosening.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA