1.
Heliyon ; 10(18): e37751, 2024 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-39318807

RESUMO

There are numerous variables governing the formation of new bone around a dental implant. Of those variables, the implant surface is an important factor influencing the quality of osseointergration. Numerous techniques and materials have been used to alter the surface of an implant to enhance osseointergration and improve the survival and success rate. One such modification is utilizing graphene to modify the surface of an implant. This paper summarizes data collected form articles published in online databases in the past 10 years about the various means of modifying the implant surfaces and provides an in-depth review of the impact of graphene incorporation in dental implants. The document comprised of different sections and emphasized on the use of graphene as an implant surface coating material. The role of graphene on flexural strength, hardness and corrosion resistance have been discussed under mechanical properties whereas the potential of this combination on the osteogenesis, osseointergration and soft tissue seal is covered under biological properties. Lastly, how this combination acts as a drug delivery carrier and renders antimicrobial property has been addressed under pharmacological properties. This review has highlighted the various applications of graphene in the field of implant dentistry. It has outlined the various implant surface modifying methods and thrown light on the various affect this combination has on the mechanical, biological and pharmacological properties. Considering the various research done on the material, it can be concluded that graphene does have a bright future in implant dentistry and continued research in this area will provide fruitful benefits.

2.
Colloids Surf B Biointerfaces ; 245: 114237, 2024 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-39293292

RESUMO

Titanium (Ti) is an ideal material for dental implants due to its excellent properties. However, corrosion and mechanical wear lead to Ti ions and particles release, triggering inflammatory responses and bone resorption. To overcome these challenges, surface modification techniques are used, including micro-arc oxidation (MAO). MAO creates adherent, porous coatings on Ti implants with diverse chemical compositions. In this context, zirconia element stands out in its wear and corrosion properties associated with low friction and chemical stability. Therefore, we investigated the impact of adding zirconium oxide (ZrO2) to Ti surfaces through MAO, aiming for improved electrochemical and mechanical properties. Additionally, the antimicrobial and modulatory potentials, cytocompatibility, and proteomic profile of surfaces were investigated. Ti discs were divided into four groups: machined - control (cpTi), treated by MAO with 0.04 M KOH - control (KOH), and two experimental groups incorporating ZrO2 at concentrations of 0.04 M and 0.08 M, composing the KOH@Zr4 and KOH@Zr8 groups. KOH@Zr8 showed higher surface porosity and roughness, even distribution of zirconia, formation of crystalline phases like ZrTiO4, and hydrophilicity. ZrO2 groups showed better mechanical performance including higher hardness values, lower wear area and mass loss, and higher friction coefficient under tribological conditions. The formation of a more compact oxide layer was observed, which favors the electrochemical stability of ZrO2 surfaces. Besides not inducing greater biofilm formation, ZrO2 surfaces reduced the load of pathogenic bacteria evidenced by the DNA-DNA checkerboard analysis. ZrO2 surfaces were cytocompatible with pre-osteoblastic cells. The saliva proteomic profile, evaluated by liquid chromatography coupled with tandem mass spectrometry, was slightly changed by zirconia, with more proteins adsorbed. KOH@Zr8 group notably absorbed proteins crucial for implant biological responses, like albumin and fibronectin. Incorporating ZrO2 improved the mechanical and electrochemical behavior of Ti surfaces, as well as modulated biofilm composition and provided suitable biological responses.

3.
J Orthop Res ; 2024 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-39282769

RESUMO

This study aimed to investigate the biocompatibility and osseointegration of novel titanium (Ti) implants with a perforated part with high surface roughness (Ra >4 µm) and a smooth solid part (test group), as compared to smooth solid Ti implants (control group; Ra < 0.8 µm). Test and control implants were implanted in rabbit femurs. After 4 and 15 weeks, host tissue reaction and quality of tissue formed were evaluated with histopathology, while micro-CT scans were used to quantitatively assess bone-implant contact (BIC), surrounding bone formation, and bone ingrowth. After 4 and 15 weeks, minimal host reaction was found in the test group. Histopathological analysis showed new bone formation around the implants in both the test and control groups after 4 weeks. Furthermore, additional bone growth was often observed within the holes of the test implants. After 15 weeks, the test implants showed high bone ingrowth and the presence of mature bone in direct contact with the implant surface, whereas, bone ingrowth was poorer for the control group with 30% of the control implants, showing larger gaps at the bone-implant interface. Quantitative micro-CT analysis revealed comparable BIC and bone formation in both groups at 4 weeks, but higher BIC and more bone formation in the test group than in the control group after 15 weeks. No significant differences were observed in any of the analyses. In conclusion, partially perforated, high-roughness Ti implants showed excellent osseointegration and minimal host reaction, indicating their potential for orthopedic applications in bone repair and regeneration.

4.
Bone ; 188: 117242, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39209139

RESUMO

As obesity rates continue to rise, the prevalence of metabolic dysfunction and alcohol-associated steatotic liver disease (MetALD), a new term for Nonalcoholic Fatty Liver Disease (NAFLD), also increases. In an aging population, it is crucial to understand the interplay between metabolic disorders, such as MetALD, and bone health. This understanding becomes particularly significant in the context of implant osseointegration. This study introduces an in vitro model simulating high lipogenesis through the use of human Mesenchymal Stroma Cells-derived adipocytes, 3D intrahepatic cholangiocyte organoids (ICO), and Huh7 hepatocytes, to evaluate the endocrine influence on osteoblasts interacting with titanium. We observed a significant increase in intracellular fat accumulation in all three cell types, along with a corresponding elevation in metabolic gene expression compared to the control groups. Notably, osteoblasts undergoing mineralization in this high-lipogenesis environment also displayed lipid vesicle accumulation. The study further revealed that titanium surfaces modulate osteogenic gene expression and impact cell cycle progression, cell survival, and extracellular matrix remodeling under lipogenic conditions. These findings provide new insights into the challenges of implant integration in patients with obesity and MetALD, offering a deeper understanding of the metabolic influences on bone regeneration and implant success.


Assuntos
Lipogênese , Osteogênese , Titânio , Humanos , Titânio/farmacologia , Osteogênese/efeitos dos fármacos , Lipogênese/efeitos dos fármacos , Adipócitos/metabolismo , Células-Tronco Mesenquimais/metabolismo , Osteoblastos/metabolismo , Osteoblastos/efeitos dos fármacos , Organoides/metabolismo , Hepatócitos/metabolismo
5.
Cureus ; 16(7): e64280, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39130852

RESUMO

Introduction Zygomatic implants (ZIs) have emerged as a promising option for rehabilitating completely edentulous patients with severe maxillary atrophy. These implants anchor into the zygomatic bone, bypassing the need for extensive grafting procedures. Success rates in dental and craniofacial implant surgeries can be influenced by several surgical factors, including suture techniques, flap design, and treatment planning. The research aimed to present the clinical outcomes and complications in individuals with severely resorbed maxillae who underwent prosthodontic rehabilitation using the Quad Zygoma Protocol (QZP) and the Anatomy-Guided Approach (AGA), focusing on long-term assessment. Material and methods Data for this retrospective study were extracted from the institution's patient database, involving a meticulous review of patient records. This comprehensive examination encompassed demographic data, preoperative assessments, details of surgical procedures, postoperative complications, and subsequent follow-up evaluations. Patients with severe maxillary bone deficiencies resulting in complete edentulism, due to inadequate bone quality and quantity in both anterior and posterior regions, were selected for inclusion. Exclusion criteria were applied to individuals with incomplete records or insufficient follow-up data, as well as those who underwent alternative treatment modalities or presented with comorbidities potentially impacting implant outcomes. The selected patients underwent treatment utilizing the QZP, with each participant subjected to a minimum three-year follow-up period. The implant survival rate, prosthetic success, complications, and Oral Health-Related Quality of Life using the OHIP-14 questionnaire were assessed. Results At the end of the follow-up period involving 12 patients (eight men, four women) with 43 ZIs - 37 from Neodent, four from Nobel Biocare, and two from Norris - with a mean duration of 4.3 years (range: 1.2-5.4), the overall success rate stood at 99.08%, with only 1 out of 42 implants failing. All patients received immediate loading with an acrylic prosthesis, proving effective in 98.2% of cases. The most common issues observed were localized soft tissue inflammation (35.7%) and sinus inflammation (12.5%), occurring after mean follow-up periods of 1.2 and 3.5 years, respectively. In 12 patients, the mean score of the OHIP-14 questionnaire was 1.6 ± 2.6, with a follow-up period of 5 ± 0.6 years. Conclusion The QZP has consistently demonstrated excellent long-term success in restoring severely reduced maxillary structures. An immediate loading approach could aid in stabilizing ZIs through cross-arch support.

6.
J Clin Med ; 13(15)2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39124755

RESUMO

Objective: The goal of this systematic review and meta-analysis was to assess whether there were clinically relevant differences in the treatment of edentulous areas comparing zirconia (Zr) and titanium (Ti) dental implants. The null hypothesis is that no differences can be observed in terms of the clinical parameters; the positive hypothesis I is that Zr implants have generally better results compared to Ti implants; and the positive hypothesis II is that Ti implants have a generally superior result than Zr implants. Methods: This review work was registered on the PROSPERO platform, and its development was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement. The electronic search process was conducted on three databases (PubMed/Scopus/Web of Science), including randomized controlled trials (RCTs) from the past 10 years (up to April 2024). Identified articles were analyzed and included/excluded based on pre-defined selection and exclusion criteria. The quality assessment and risk of bias were evaluated using a Cochrane risk-of-bias assessment tool specifically designed for randomized trials (RoB2). A meta-analysis was conducted to correlate different treatment options based on the described outcomes; a random-effects model was used in the analysis of the variables. The analysis of heterogeneity was conducted by means of Cochran's Q-test and Higgins' I2 statistic. Results: Six RCTs were enrolled; 152 patients (90 males and 62 females) and 448 implants (267 Zr and 181 Ti) were included. Dental implant placement involved both the maxillary and mandibular arches. The implant sites showed heterogeneity in receiving Zr and Ti dental implants; in particular, 22 dental implants were placed in the mid-palatal region and 426 dental implants in the alveolar region (255 were in Zr and 171 in Ti). Regarding the success rate, it was better for Zr but with no statistical difference (p > 0.05); bleeding on probing had slight differences between Ti with 0.34% ± 0.42 and Zr with 0.26% ± 0.36 (p > 0.05); plaque score showed 0.46 ± 0.47 for Ti compared to 0.44 ± 0.49 for Zr (p > 0.05); no statistically significant difference was observed for pink esthetic score (PES). Statistically significant results were found for survival rate, which favored Ti implants (77.6%) compared to Zr (70.3%) (p < 0.05), and for marginal bone loss, which showed less loss in Ti implants (0.18 mm ± 0.47) compared to 0.42 mm ± 0.40 in Zr at 12 months (p < 0.001). Conclusions: The present systematic review and meta-analysis identified the positive hypothesis I and rejected the null and positive hypothesis II; it was possible to conclude that Ti dental implants have a better survival rate and less marginal bone loss than Zr dental implants after 1-year follow-up.

7.
J Stomatol Oral Maxillofac Surg ; : 102019, 2024 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-39182846

RESUMO

INTRODUCTION: Long-term enophthalmos and diplopia resulting from orbital bone loss pose significant challenges in reconstructive surgery. This study evaluated the effectiveness of patient-specific porous titanium implants (PSIs) for addressing these conditions. MATERIALS AND METHODS: This retrospective study involved 12 patients treated at Croix-Rousse Hospital, Lyon, from April 2015 to April 2022 who underwent late reconstruction via PSI for unilateral complex orbital bone loss. These implants were customized via 3D mirroring techniques on the basis of high-resolution computed tomography (CT) scans of the patients' unaffected orbits. RESULTS: All 12 patients presented with significant preoperative enophthalmos, with an average displacement of 3.24 mm, which was effectively corrected postoperatively to an average of 0.17 mm (p < 0.001). Orbital volume notably improved from a preoperative average of 3.38 mL to 0.37 mL postsurgery (p < 0.001). Functional improvements were evident as both enophthalmos and diplopia resolved completely. The Lancaster test revealed an improvement in the visual field, with 83.3 % of patients achieving normal results postoperatively. DISCUSSION: By ensuring anatomical accuracy, patient-specific porous titanium implants, tailored from patient-specific imaging and fabricated via advanced 3D printing technology, provide a precise, effective, and reliable solution for reconstructing complex orbital defects and performing complicated revision surgeries.

8.
Artigo em Inglês | MEDLINE | ID: mdl-39056305

RESUMO

OBJECTIVE: To assess the clinical, radiographic and patient-reported outcomes (PROMs) of posterior zirconia and titanium implants at 1 year of implant loading. MATERIALS AND METHODS: Forty-two patients with two adjacent missing teeth were enrolled in a randomized controlled trial with a within-subject controlled design. Each patient received one zirconia (Zr) and one titanium (Ti) implant, with the mesial and distal positions randomized. The implant restoration consisted of multiple layered zirconia, with the buccal aspect veneered. In group Zr, the restoration was intraorally cemented onto the one-piece Zr implant, whereas in group Ti, the restoration was extraorally cemented onto the titanium base abutment and intraorally screw-retained onto the Ti implant. Examinations were performed following restoration delivery at baseline (BL) and at 1 year. Measurements included clinical parameters, radiographic outcomes (MBL) and PROMs. RESULTS: Bleeding on probing showed an increase from BL to 1 year (34 ± 30% for Zr; 25 ± 21% for Ti). MBL remained stable with minimal changes from BL to 1 year, measuring 0.1 ± 0.4 mm (mean ± SD) for Zr and -0.1 ± 0.7 mm for Ti. Veneering fractures were the most frequent technical complication and amounted to 17.5% in group Zr and 5% in group Ti (p = .100). Patients preferred Zr implants for their soft tissue color, with a significant difference in perception between patients and clinicians (p < .017). CONCLUSION: The study showed that both Zr and Ti implants had similar clinical outcomes, despite a high prevalence of mucositis and a few technical complications. Both implant types demonstrated stable marginal bone levels and similar patient-reported outcome measures.

9.
Front Chem ; 12: 1426865, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39036659

RESUMO

Introduction: Smart multifunctional surfaces targeting intricate biological events or versatile therapeutic strategies are imminent to achieve long-term transmucosal implant success. Methods: This study used dopamine (DA), graphene oxide (GO), and type IV collagen (COL-IV) to construct multilayer nanofilms (DGCn) based on their universal adhesive and biomimetic properties to design a versatile and bioactive titanium implant. The characterization of DGCn on different titanium surfaces was performed, and its loading capacity, release profile, in situ gene delivery, and in vitro biological properties were preliminarily evaluated. Results: Our results demonstrate that hydrogenated TiO2 nanotubes (H) provide a better platform for the DGCn coating than machined Ti and air-TiO2 nanotubes. The H-DGC10 displayed the most stable surface with excellent loading capacity, sustained-release profile, and in situ gene transfection efficiency; this could be due to the high specific surface area of H and GO, as well as the functional groups in H, DA, and GO. Moreover, the H-DGC10 exhibited good biocompatibility for human oral epithelial cells and promoted the expression of integrin ß4 and laminin 332, both being hemidesmosome-related proteins. Discussion: Our findings suggest that H-DGCn can be designed as a smart multifunctional interface for titanium implants to achieve long-term transmucosal implant success and aid in versatile therapeutic strategies.

10.
Materials (Basel) ; 17(13)2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38998445

RESUMO

In this work, we show the in vitro anticancer potential of surgical wires, obtained from zinc (ZnMg0.004) or magnesium (MgCa0.7) alloys by spatial technology comprising casting, extrusion, and final drawing processes. We also present the selective anticancer effects of applied soluble multilayer nanocoatings of zinc and magnesium onto titanium surfaces using the pulse laser deposition method. In the latter, the titanium samples were produced via 3D printing using the selective laser melting method and coated with various combinations of zinc and magnesium layers. For cytotoxicity studies, human dental pulp-derived stem cells (hDPSCs) and human osteosarcoma SaOS-2 cell line were used as representatives of healthy and cancer cells. Cells were examined against the 0.3-3.0 cm2/mL material extract ratios obtained from experimental and steel surgical wires, the latter being the current clinical industry standard. The MgCa0.7 alloy wires were approx. 1.5 times more toxic to cancer cells at all examined extract ratios vs. the extracts from steel surgical wires that exhibited comparable toxicity towards healthy and cancer cells. The ZnMg0.004 alloy wires displayed increased toxicity towards cancer cells with decreasing extract ratios. This was also reflected in the increased anticancer effectiveness, calculated based on the viability ratio of healthy cells to cancer cells, from 1.1 to 4.0 times. Healthy cell viability remained at 80-100%, whereas cancer cell survival fluctuated at 20-75%, depending on the extract ratio. Furthermore, the culture of normal or cancer cells on the surface of Zn/Mg-coated titanium allowed us to select combinations of specific coating layers that yielded a comparable anticancer effectiveness to that observed with the experimental wires that ranged between 2 and 3. Overall, this work not only demonstrates the substantial anticancer properties of the studied wires but also indicates that similar anticancer effects can be replicated with appropriate nanocoatings on titanium samples. We believe that this work lays the groundwork for the future potential development of the category of new implants endowed with anticancer properties.

11.
Phys Med Biol ; 69(16)2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38986478

RESUMO

Objective.This study aims to assess the composition of scattered particles generated in proton therapy for tumors situated proximal to some titanium (Ti) dental implants. The investigation involves decomposing the mixed field and recording Linear Energy Transfer (LET) spectra to quantify the influence of metallic dental inserts located behind the tumor.Approach.A therapeutic conformal proton beam was used to deliver the treatment plan to an anthropomorphic head phantom with two types of implants inserted in the target volume (made of Ti and plastic, respectively). The scattered radiation resulted during the irradiation was detected by a hybrid semiconductor pixel detector MiniPIX Timepix3 that was placed distal to the Spread-out Bragg peak. Visualization and field decomposition of stray radiation were generated using algorithms trained in particle recognition based on artificial intelligence neural networks (AI NN). Spectral sensitive aspects of the scattered radiation were collected using two angular positions of the detector relative to the beam direction: 0° and 60°.Results.Using AI NN, 3 classes of particles were identified: protons, electrons & photons, and ions & fast neutrons. Placing a Ti implant in the beam's path resulted in predominantly electrons and photons, contributing 52.2% of the total number of detected particles, whereas for plastic implants, the contribution was 65.4%. Scattered protons comprised 45.5% and 31.9% with and without metal inserts, respectively. The LET spectra were derived for each group of particles identified, with values ranging from 0.01 to 7.5 keVµm-1for Ti implants/plastic implants. The low-LET component was primarily composed of electrons and photons, while the high-LET component corresponded to protons and ions.Significance.This method, complemented by directional maps, holds the potential for evaluating and validating treatment plans involving stray radiation near organs at risk, offering precise discrimination of the mixed field, and enhancing in this way the LET calculation.


Assuntos
Transferência Linear de Energia , Imagens de Fantasmas , Terapia com Prótons , Terapia com Prótons/métodos , Terapia com Prótons/instrumentação , Próteses e Implantes , Espalhamento de Radiação , Humanos , Redes Neurais de Computação , Planejamento da Radioterapia Assistida por Computador/métodos
12.
Biomed Eng Online ; 23(1): 68, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39020369

RESUMO

BACKGROUND: A strong seal of soft-tissue around dental implants is essential to block pathogens from entering the peri-implant interface and prevent infections. Therefore, the integration of soft-tissue poses a challenge in implant-prosthetic procedures, prompting a focus on the interface between peri-implant soft-tissues and the transmucosal component. The aim of this study was to analyse the effects of sandblasted roughness levels on in vitro soft-tissue healing around dental implant abutments. In parallel, proteomic techniques were applied to study the interaction of these surfaces with human serum proteins to evaluate their potential to promote soft-tissue regeneration. RESULTS: Grade-5 machined titanium discs (MC) underwent sandblasting with alumina particles of two sizes (4 and 8 µm), resulting in two different surface types: MC04 and MC08. Surface morphology and roughness were characterised employing scanning electron microscopy and optical profilometry. Cell adhesion and collagen synthesis, as well as immune responses, were assessed using human gingival fibroblasts (hGF) and macrophages (THP-1), respectively. The profiles of protein adsorption to the surfaces were characterised using proteomics; samples were incubated with human serum, and the adsorbed proteins analysed employing nLC-MS/MS. hGFs exposed to MC04 showed decreased cell area compared to MC, while no differences were found for MC08. hGF collagen synthesis increased after 7 days for MC08. THP-1 macrophages cultured on MC04 and MC08 showed a reduced TNF-α and increased IL-4 secretion. Thus, the sandblasted topography led a reduction in the immune/inflammatory response. One hundred seventy-six distinct proteins adsorbed on the surfaces were identified. Differentially adsorbed proteins were associated with immune response, blood coagulation, angiogenesis, fibrinolysis and tissue regeneration. CONCLUSIONS: Increased roughness through MC08 treatment resulted in increased collagen synthesis in hGF and resulted in a reduction in the surface immune response in human macrophages. These results correlate with the changes in protein adsorption on the surfaces observed through proteomics.


Assuntos
Fibroblastos , Macrófagos , Propriedades de Superfície , Humanos , Fibroblastos/metabolismo , Fibroblastos/citologia , Macrófagos/metabolismo , Macrófagos/citologia , Dente Suporte , Titânio/química , Gengiva/citologia , Gengiva/metabolismo , Proteômica , Adesão Celular , Colágeno/metabolismo , Colágeno/química , Adsorção
13.
Artigo em Inglês | MEDLINE | ID: mdl-38881643

RESUMO

Background: Modifying the dental implant's surface texture enhances its biological response to the bone and implant‒tissue interface, resulting in the successful support of forces. This study assessed the impact of sandblasting, sandblasting plus acid etching, Er,Cr:YSGG laser, and propolis implant surface treatments and occlusal load on the osseointegration of titanium dental implants in dogs. Methods: Seventy-two titanium dental implants with a diameter of 4 mm and a length of 10 mm were divided into four groups according to implant surface modifications (n=18 for each group): group A: sandblasting plus acid etching, group B: sandblasting with Al2 O3, group C: Er,Cr:YSGG laser, group D: propolis coating. Twenty-four local breed male dogs were used. Premolar teeth (P1, P2, and P3) were extracted on the left side of the mandible, and after 12 weeks of bone healing, implants were unilaterally installed. The osseointegration at three study times from implant installation (14, 90, and 180 days) was evaluated. The dog jaws were scanned using an intraoral scanner for the virtual design of screw-retained three-unit crowns after 90 days of osseointegration. Final radiographs were taken before the animals were sacrificed at 14, 90, and 180 days, and the histological analysis was performed. Results: Radiographic analysis showed new bone formation (NBF) along and in contact with the implant surface of the treated groups. The histological analysis after 14 days in groups A and B revealed a uniform and ongoing pattern of bone growth and many osteoblasts with few osteocytes within lacunae in new bone trabeculae. Group C showed an increase in the number of osteoblasts lining thin bone trabeculae. Group D showed a generative power concerning bone. At 90 days, there was increased bone ingrowth, and the new bone matured in all the treated implant groups. At 180 days, dense mature bone apposition was in direct contact with delayed-loaded implant surfaces. Conclusion: A radiographic examination revealed that surface modification significantly impacted osseointegration, with a strong bond between the implant surface and the surrounding bone. The histological sections at the 14-day interval revealed obvious bone remodeling activity, especially in sandblasting plus acid etching and sandblasting-modified implant surface groups. At the 90-day interval, bone ingrowth had increased, and the new bone became mature, especially in sandblasting and propolis surface modification groups. After 180 days of the delayed-loaded implant osseointegration, differences were observed between different implant-treated groups with a remarkable remodeling of the bone, especially in the propolis coating group.

14.
Cureus ; 16(4): e57385, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38694672

RESUMO

Background The use of surface coatings to enhance the properties lacking in titanium has attracted significant focus in recent times. Hafnium nitride (HfN) coatings could be explored as promising in the osteoinductive properties of titanium implants. HfN exhibits excellent mechanical attributes, such as hardness and wear resistance, and is often used as a coating on high-end equipment for protection. The findings from this research may carve a new path for the production and optimization of HfN coatings to enhance the longevity and augment properties of implant materials. Thus, the present study was orchestrated to elucidate the surface morphology of HfN coating, ultimately contributing to the advancement of dental implant biomaterials. Materials and methods A total of twenty samples of medical grade commercially pure titanium screws (2 mm diameter and 7 mm length) were procured from G. R. Bioure Surgical System Pvt. Ltd., Ravali, Uttar Pradesh, India, and ten samples were reacted with HfN (0.1 M) (Nano Research Elements, Kurukshetra, Haryana, India) in 100% ethanol and stirred continuously for about 48 hours. Then these screw samples were immersed in the prepared colloidal suspension and sintered for two hours at 400 degrees centigrade. The implant screws were affixed onto metal supports. The magnifications for photomicrographs at ×30, ×200, ×1,500, ×3,000, and ×5,000 were standardized. Elementary semi-quantitative analysis of both dental implants was conducted using energy-dispersive X-ray spectrometry (EDX) coupled with the field emission scanning electron microscope (FE-SEM) equipment (JEOL Ltd., Akishima, Tokyo, Japan). The software used for the analysis of the obtained images is SEM Center. Results The surface analysis using the scanning electron microscope (SEM) showed the coating of HfN over titanium screws. The difference in surface morphology of both the group of implant screws can be visualized under 40.0 and 10.0 mm working distance (WD) for both groups. The surface analysis using the EDX of uncoated titanium screws shows five elements in the spectrum: titanium (Ti), oxygen (O), aluminum (Al), carbon (C), and vanadium (V). The EDX of the HfN-coated screws has two additional metals dispersed in the spectrum, hafnium (Hf). The element characteristics are tabulated with their apparent concentration, k ratio, line type, weight percentage, standard label, and factory label for uncoated titanium screws and HfN-coated titanium screws. Conclusion The study evaluated HfN coating over medical grade commercially pure titanium. The surface topography of coated versus uncoated was visualized. The scanning electron microscope (SEM) images showed a homogenous coating over the titanium surfaces, and the EDX showed elemental dispersion of the coated implant. The study aims to provide a comprehensive understanding of the coating's surface morphology, which will aid in the development of more durable and biocompatible implants. This thereby provides a promising scope for further research of this novel metal coating for use in the biomedical sectors, specifically for dental implants.

15.
Materials (Basel) ; 17(10)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38793397

RESUMO

Titanium implants undergo an aging process through surface hydrocarbon deposition, resulting in decreased wettability and bioactivity. Plasma treatment was shown to significantly reduce surface hydrocarbons, thus improving implant hydrophilicity and enhancing the osseointegration process. This study investigates the effect of plasma surface treatment on bone-to-implant contact (BIC) of implants presenting a nanostructured calcium-incorporated surface (XPEED®). Following a Randomized Controlled Trial (RCT) design, patients undergoing implant surgery in the posterior maxilla received additional plasma-treated (n = 7) or -untreated (n = 5) 3.5 × 8 mm implants that were retrieved after a 4-week healing period for histological examination. Histomorphometric analysis showed that plasma-treated implants exhibited a 38.7% BIC rate compared to 22.4% of untreated implants (p = 0.002), indicating enhanced osseointegration potential. Histological images also revealed increased bone formation and active osteoblastic activity around plasma-treated implants when compared to untreated specimens. The findings suggest that plasma treatment improves surface hydrophilicity and biological response, facilitating early bone formation around titanium implants. This study underscores the importance of surface modifications in optimizing implant integration and supports the use of plasma treatment to enhance osseointegration, thereby improving clinical outcomes in implant dentistry and offering benefits for immediate and early loading protocols, particularly in soft bone conditions.

16.
Biomater Adv ; 160: 213861, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38663159

RESUMO

Novel strategies employing mechano-transducing materials eliciting biological outcomes have recently emerged for controlling cellular behaviour. Targeted cellular responses are achieved by manipulating physical, chemical, or biochemical modification of material properties. Advances in techniques such as nanopatterning, chemical modification, biochemical molecule embedding, force-tuneable materials, and artificial extracellular matrices are helping understand cellular mechanotransduction. Collectively, these strategies manipulate cellular sensing and regulate signalling cascades including focal adhesions, YAP-TAZ transcription factors, and multiple osteogenic pathways. In this minireview, we are providing a summary of the influence that these materials, particularly titanium-based orthopaedic materials, have on cells. We also highlight recent complementary methodological developments including, but not limited to, the use of metabolomics for identification of active biomolecules that drive cellular differentiation.


Assuntos
Mecanotransdução Celular , Osteogênese , Osteogênese/fisiologia , Humanos , Titânio/química , Animais , Diferenciação Celular , Propriedades de Superfície , Materiais Biocompatíveis/química , Matriz Extracelular/metabolismo , Matriz Extracelular/fisiologia , Matriz Extracelular/química
17.
J Orthop Res ; 42(9): 1984-1997, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38644051

RESUMO

Immobilization-induced skeletal unloading results in muscle atrophy and rapid bone loss, thereby increasing the risk of falling and the need for implant therapy in patients with extended bed rest or neuromuscular injuries. Skeletal unloading causes bone loss by altering bone growth and resorption, suggesting that implant performance might be affected. To test this, we focused on early events in implant osseointegration. We used the rat sciatic neurectomy-induced disuse model under two different settings. In Study 1, 16 Sprague Dawley rats (SD) were separated into control, sham operated+cast immobilization, and sciatic neurectomy+casting groups; titanium implants with multiscale microtextured topography and hydrophilic chemistry (modSLA) were inserted in the distal femoral metaphysis. Neurectomy surgeries and casting were performed at the same surgical setting as implant placement; rats were euthanized 4 weeks post-implantation. In Study 2, we established the unloaded condition before implantation. A total of 12 SD rats were divided into control and sciatic+femoral neurectomy groups. A total of 24 days after sciatic and femoral neurectomy surgery, rats received implants. Study 2 rats were euthanized at 4 weeks post-implantation. MicroCT and histomorphometry showed that trabecular bone and osseointegration were reduced when disuse was established before implantation. Osteoblasts isolated from Study 1 sciatic neurectomy tibial bones exhibited impaired differentiation on modSLA culture disks, revealing a possible mechanism responsible for the decreased osseointegration observed in the Study 2 rats. This study addressed the importance of considering the mechanical unloading and muscle function history before implant insertion and suggests that implant performance was reduced due to poor cellular ability to regenerate.


Assuntos
Osseointegração , Ratos Sprague-Dawley , Titânio , Animais , Masculino , Ratos , Nervo Isquiático/lesões , Propriedades de Superfície , Denervação , Fêmur/cirurgia , Modelos Animais de Doenças , Osteoblastos
18.
Cureus ; 16(3): e55545, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38576662

RESUMO

Yellow nail syndrome is a rare condition occurring sporadically, with an extremely low prevalence rate. This syndrome classically presents with a triad of lower extremity edema, yellow nails, and mucosal issues such as pleural effusion and/or chronic sinusitis. Two out of the three features are deemed sufficient to diagnose a person with yellow nail syndrome. We present a rare case of yellow nail syndrome that began with chronic leg swelling and later progressed to the development of an asymptomatic pleural effusion and finally discoloration of nails. In our case, the patient did have a significant recent history of a total knee replacement with a titanium implant. Of note was the chronology of events including leg edema and asymptomatic pleural effusion which were present even before the titanium knee implant. The third feature of the hardening and yellow discoloration of the nails was found to have developed following the knee replacement. Interestingly, on further evaluation, he was found to have IgM deficiency.

19.
J Orthop Res ; 42(8): 1820-1830, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38433320

RESUMO

Minimally invasive sacroiliac joint fusion has become increasingly prevalent and is described to reduce pain and improve function. In some patients, pain can recur several months after primary surgery. Lack of early implant osseointegration might be a cause of pain and hence an indication for revision surgery. Triangular titanium implants are the most documented implant for minimally invasive sacroiliac joint fusion. There is, however, no knowledge of how triangular titanium implants osseointegrate in humans and whether fusion is induced over the sacroiliac joint. During planned revision surgery due to recurrent pain, six triangular titanium implants were retrieved from six different patients at median 9 months from primary surgery. All six implants were scanned using microcomputed tomography. The presence or absence of bone in-growth, on-growth, and through-growth of the implants was evaluated as an indication of implant osseointegration. Three of six implants showed no or minor signs of osseointegration. Of the three remaining implants, one showed partial osseointegration and two implants showed high degrees of osseointegration. This study showed that triangular titanium implants can osseointegrate into host bone in humans. When osseointegration occurs, triangular titanium implants can give fusion across the sacroiliac joint.


Assuntos
Osseointegração , Articulação Sacroilíaca , Titânio , Humanos , Articulação Sacroilíaca/cirurgia , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Idoso , Microtomografia por Raio-X , Fusão Vertebral/métodos , Fusão Vertebral/instrumentação
20.
Biomaterials ; 307: 122532, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38493670

RESUMO

The poor efficiency of US-responsive coatings on implants restricts their practical application. Immunotherapy that stimulates immune cells to enhance their antibacterial activity is expected to synergize with sonodynamic therapy for treating implant infection effectively and safely. Herein, US-responsive hybrid coatings composed of the oxygen-deficient BaTiO3 nanorod arrays and l-arginine (BaTiO3-x/LA) are designed and prepared on titanium implants for sonocatalytic therapy-cooperated immunotherapy to treat Methicillin-resistant Staphylococcus aureus (MRSA) infection. BaTiO3-x/LA can generate more oxidizing reactive oxygen species (ROS, hydroxyl radical (·OH)) and reactive nitrogen species (RNS, peroxynitrite anion (ONOO-)). The construction of nanorod arrays and oxygen defects balances the piezoelectric properties and sonocatalytic capability during US treatment. The generated piezoelectric electric field provides a sufficient driving force to separate electrons and holes, and the oxygen defects attenuate the electron-hole recombination efficiency, consequently increasing the yield of ROS during the US treatment. Moreover, nitric oxide (NO) released by l-arginine reacts with the superoxide radical (·O2-) to produce ONOO-. Since, this radical chain reaction improves the oxidizing ability between bacteria and radicals, the cell membrane (argB, secA2) and DNA (dnaBGXN) are destroyed. The bacterial self-repair mechanism indirectly accelerates bacterial death based on the transcriptome analysis. In addition to participating in the radical chain reaction, NO positively affects macrophage M1 polarization to yield potent phagocytosis to MRSA. As a result, without introducing an extra sonosensitizer, BaTiO3-x/LA exhibits excellent antibacterial activity against MRSA after the US treatment for 15 min. Furthermore, BaTiO3-x/LA facilitates macrophage M2 polarization after implantation and improves osteogenic differentiation. The combined effects of sonodynamic therapy and immunoregulation lead to an effective and safe treatment method for implant-associated infections.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Espécies Reativas de Oxigênio/metabolismo , Osteogênese , Antibacterianos/farmacologia , Óxido Nítrico/farmacologia , Oxigênio/farmacologia , Arginina
SELEÇÃO DE REFERÊNCIAS