Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(17): e37333, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-39296032

RESUMO

Casing wear is a persistent issue in oil and gas drilling facilities that call for innovative more wear-resistant materials to mitigate casing failures. The present work examines the tribological performance of a novel composite lining comprised of Kevlar honeycomb in a matrix of epoxy reinforced with Zirconia particles against hardband drillpipe tooljoint (DP-TJ). Three side loads (1000, 1200, and 1400 N) and three DP-TJ speeds (0.43, 0.76, and 1.02 m/s) were considered under dry sliding conditions. The results showed that the specific wear rate (K) increased with speed at all side loads. However, K value was found to reach a maximum, reaching 20.3*10-8 MPa-1 at 1200 N before dropping to about 8.5*10-8 MPa-1 when the load is increased to 1400 N. This decline in specific wear rate at the load of 1400 N was attributed to the growth of a double transfer layer through the alignment of zirconia particles in the lining. The scanning electron microscope (SEM) images of worn surfaces revealed that higher K values are associated with more adhesion, delamination, and fiber breakage. Energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD) analysis of the worn surface and the debris collected after the wear test reveals minimal wear of DP-TJ. The epoxy/Kevlar-honeycomb composite lining demonstrated appreciable wear resistance even under dry sliding conditions.

2.
Polymers (Basel) ; 16(16)2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39204494

RESUMO

The aim of this study was to investigate the tribological characteristics of commercially available high-strength polyphthalamide-based composites with great contents (30-50 wt.%) of both carbon and glass fibers in point and linear contacts against metal and ceramic counterfaces under dry friction and oil-lubricated conditions at various loads and sliding speeds. The lengths of both types of fibers were varied simultaneously with their contents while samples were fabricated from granules by injection molding. When loading PPA with 30 wt.% SCFs at an aspect ratio (AR) of 200, the ultimate tensile strength and the elastic modulus increased up to 142.7 ± 12.5 MPa and 12.9 ± 0.6 GPa, respectively. In the composites with the higher contents of reinforcing fibers PPA/40CCF and AR~1000, the ultimate tensile strength and the elastic modulus were 240 ± 3 MPa and 33.7 ± 1.9 GPa, respectively. Under the applied test conditions, a composite reinforced with 40 wt.% carbon fibers up to 100 µm long at an aspect ratio of ~1000 possessed the best both mechanical properties and tribological characteristics. One of the reasons that should be considered for improving the tribological characteristics of the composite is the fatigue wear mechanism, which is facilitated by the high filling degree, the strong interfacial adhesion, and the great aspect ratio for fibers. Under the oil-lubricated conditions, both friction coefficients and wear rates decreased, so such friction units could be implemented whenever possible. The reported data can be used as practical recommendations for applying fibrous polyphthalamide-based composites as friction unit components.

3.
Front Bioeng Biotechnol ; 12: 1412586, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39081331

RESUMO

Introduction: Titanium (Ti)-molybdenum(Mo) composites reinforced with ceramic nanoparticles have recently significant interest among researchers as a new type of bio-inert material used for dental prosthetic applications due to its biocompatibility, outstanding physical, mechanical and corrosion properties. The current work investigates the impact of alumina (Al2O3) nanoparticles on the properties of the Ti-12Mo composite, including microstructure, density, hardness, wear resistance, and electrochemical behavior. Methods: Ti-12Mo/xAl2O3 nanocomposites reinforced with different Al2O3 nanoparticles content were prepared. The composition of each sample was adjusted through the mechanical milling of the elemental constituents of the sample for 24 h under an argon atmosphere. The produced nanocomposite powders were then cold-pressed at 600 MPa and sintered at different temperatures (1,350°C, 1,450°C, and 1,500°C) for 90 min. Based on density measurements using the Archimedes method, the most suitable sintering temperature was found to be 1,450°C. The morphology and chemical composition of the milled and sintered composites were analyzed using back-scattering scanning electron microscopy (SEM) and X-ray diffraction (XRD). Results and Discussion: The results showed that the addition of Mo increased the Ti density from 99.11% to 99.46%, while the incorporation of 15wt% Al2O3 in the Ti-12Mo composite decreased the density to 97.28%. Furthermore, the Vickers hardness and wear behavior of the Ti-Mo composite were enhanced with the addition of up to 5 wt% Al2O3. The sample contains 5 wt% Al2O3 exhibited a Vickers hardness of 593.4 HV, compared to 320 HV for pure Ti, and demonstrated the lowest wear rate of 0.0367 mg/min, compared to 0.307 mg/min for pure Ti. Electrochemical investigations revealed that the sintered Ti-12Mo/xAl2O3 nanocomposites displayed higher corrosion resistance against a simulated artificial saliva (AS) solution than pure Ti. The concentrations of Ti, Mo, and Al ions released from the Ti-12Mo/xAl2O3 nanocomposites in the AS solution were within the safe levels. It was found from this study that; the sample of the composition Ti-12Mo/5wt%Al2O3 exhibited appropriate mechanical properties, biocompatibility, corrosion resistance against the AS solution with acceptable ion concentration released in the biological fluids. Therefore, it can be considered as a new bio-inert material for potential applications in dental prosthetics.

4.
Materials (Basel) ; 17(14)2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-39063737

RESUMO

Porous materials have recently attracted significant attention in the aerospace and biomedical fields for addressing issues related to friction and wear. Porous materials are beneficial in applications where continuous lubrication is not feasible or for components that operate under extreme conditions, such as high speeds, elevated temperatures, and heavy loads. The pores can serve as reservoirs for liquid lubricants, which are gradually released during the operation of the components. The tribological properties of these materials depend on their porosity, the lubricants used, and any additional additives incorporated into the porous materials. This review article provides insight into common fabrication techniques for porous materials and examines their tribological performance for all three classes of materials-polymers, metals, and ceramics. Additionally, it discusses design criteria for porous self-lubricating materials by highlighting the critical properties of both the substrate and lubricants.

5.
Dent Mater ; 40(9): 1409-1416, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38926014

RESUMO

PURPOSE: This study aimed to reproduce and translate clinical presentations in an in vitro set-up and evaluate laboratory outcomes of mechanical properties (flexural strength, fatigue resistance, wear resistance) and link them to the clinical outcomes of the employed materials in the Radboud Tooth Wear Project (RTWP). MATERIALS AND METHODS: Four dental resin composites were selected. 30 discs (Ø12.0 mm, 1.2 mm thick) were fabricated for each of Clearfil TM AP-X (AP), Filtek TM Supreme XTE (FS), Estenia TM C&B (ES), and Lava Ultimate (LU). Cyclic loading (200 N, 2 Hz frequency) was applied concentrically to 15 specimens per group with a spherical steatite indenter (r = 3.18 mm) in water in a contact-load-slide-liftoff motion (105 cycles). The wear scar was analysed using profilometry and the volume loss was digitally computed. Finally, all specimens were loaded (fatigued specimens with their worn surface loaded in tension) until fracture in a biaxial flexure apparatus. The differences in volume loss and flexural strength were determined using regression analysis. RESULTS: Compared to AP and FS, ES and LU showed a significantly lower volume loss (p < 0.05). Non-fatigued ES specimens had a similar flexural strength compared to nonfatigued AP, while non-fatigued FS and LU specimens had a lower flexural strength (p < 0.001; 95 %CI: -80.0 - 51.8). The fatigue test resulted in a significant decrease of the flexural strength of ES specimens, only (p < 0.001; 95 %CI: -96.1 - -54.6). CLINICAL RELEVANCE: These outcomes concur with the outcomes of clinical studies on the longevity of these composites in patients with tooth wear. Therefore, the employed laboratory test seems to have the potential to test materials in a clinically relevant way.


Assuntos
Resinas Compostas , Resistência à Flexão , Teste de Materiais , Resinas Compostas/química , Técnicas In Vitro , Análise do Estresse Dentário , Propriedades de Superfície , Pesquisa Translacional Biomédica , Desgaste de Restauração Dentária , Humanos , Desgaste dos Dentes
6.
Materials (Basel) ; 17(10)2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38793323

RESUMO

Electrical discharge machining (EDM) is a rapidly evolving method in modern industry that manufactures highly complex components. The physical properties of a tool electrode material are significant factors in determining the effectiveness of the process, as well as the characteristics of the machined surfaces. The current trend of implementing graphite tool electrodes in manufacturing processes is observed. Innovative material engineering solutions enable graphite production with miniaturized grain size. However, the correlation between the graphite electrode grain size and the mechanism of the process removal in the EDM is a challenge for its widespread implementation in the industry. This research introduces a new method to evaluate the impact of the graphite electrode grain size and machining parameters on the material removal effectiveness, relative tool wear rate, and surface roughness (Ra) of Hastelloy C-22 following EDM with negative polarity. The study utilized new graphite materials with a grain size of 1 µm (POCO AF-5) and 10 µm (POCO EDM-180). An assessment of the impact of the EDM process parameters on the technological parameters and the development of the surface roughness was carried out. Electrical discharge machining with fine-grained graphite electrodes increases process efficiency and reduces tool wear. Graphite grains detached from the tool electrode affect the stability of electrical discharges and the efficiency of the process. Based on the experimental results, mathematical models were developed, enabling the prediction of machining effects to advance state-of-the-art manufacturing processes. The obtained mathematical models can be implemented in modern industrial EDM machines as guidelines for selecting adequate machining parameters depending on the desired process efficiency, tool wear rate, and surface roughness for advanced materials.

7.
Materials (Basel) ; 17(10)2024 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-38793512

RESUMO

The heat treatment of aluminum alloys is very important in industries where low weight in combination with high wear resistance, good strength, and hardness are important. However, depending on their chemical composition, aluminum alloys are subjected to different mechanical and thermal treatments to achieve the most favorable properties. In this study, an Al-Zn-Mg alloy was heat-treated including solution annealing at 490 °C for 1 h with subsequent artificial aging at 130, 160, and 190 °C for 1, 5, and 9 h. The hardness (HV1) and abrasive wear resistance with three different abrasive grain sizes were measured for all samples. The highest hardness was measured for the samples artificially aged at 130 °C/5 h, 227 HV1, while the lowest hardness was measured for the samples aged at 190 °C/9 h. The highest and the lowest wear resistance was also observed for the same state, i.e., artificially aged at 130 °C/5 h and 190 °C/9 h, respectively. The critical abrasive grain size was detected for some samples, where a decrease in wear rate was observed with an increase in the abrasive grain size from the medium value to the largest. The Response Surface Methodology (RSM) was applied to demonstrate the influence of the input parameters on the material wear rate.

8.
Sci Rep ; 14(1): 4590, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38409139

RESUMO

This study is an attempt for comprehensive, combining experimental data with advanced analytical techniques and machine learning for a thorough understanding of the factors influencing the wear and cutting performance of multi-blade diamond disc cutters on granite blocks. A series of sawing experiments were performed to evaluate the wear and cutting performance of multi blade diamond disc cutters with varying diameters in the processing of large-sized granite blocks. The multi-layer diamond segments comprising the Iron (Fe) based metal matrix were brazed on the sawing blades. The segment's wear was studied through micrographs and data obtained from the Field Emission Scanning Electron Microscopy (FESEM) and Energy Dispersive X-ray (EDS). Granite rock samples of nine varieties were tested in the laboratory to determine the quantitative rock parameters. The contribution of individual rock parameters and their combined effects on wear and cutting performance of multi blade saw were correlated using statistical machine learning methods. Moreover, predictive models were developed to estimate the wear and cutting rate based on the most significant rock properties. The point load strength index, uniaxial compressive strength, and deformability, Cerchar abrasivity index, and Cerchar hardness index were found to be the significant variables affecting the sawing performance.

9.
Polymers (Basel) ; 15(20)2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37896301

RESUMO

Polymer composites are a class of material that are gaining a lot of attention in demanding tribological applications due to the ability of manipulating their performance by changing various factors, such as processing parameters, types of fillers, and operational parameters. Hence, a number of samples under different conditions need to be repeatedly produced and tested in order to satisfy the requirements of an application. However, with the advent of a new field of triboinformatics, which is a scientific discipline involving computer technology to collect, store, analyze, and evaluate tribological properties, we presently have access to a variety of high-end tools, such as various machine learning (ML) techniques, which can significantly aid in efficiently gauging the polymer's characteristics without the need to invest time and money in a physical experimentation. The development of an accurate model specifically for predicting the properties of the composite would not only cheapen the process of product testing, but also bolster the production rates of a very strong polymer combination. Hence, in the current study, the performance of five different machine learning (ML) techniques is evaluated for accurately predicting the tribological properties of ultrahigh molecular-weight polyethylene (UHMWPE) polymer composites reinforced with silicon carbide (SiC) nanoparticles. Three input parameters, namely, the applied pressure, holding time, and the concentration of SiCs, are considered with the specific wear rate (SWR) and coefficient of friction (COF) as the two output parameters. The five techniques used are support vector machines (SVMs), decision trees (DTs), random forests (RFs), k-nearest neighbors (KNNs), and artificial neural networks (ANNs). Three evaluation statistical metrics, namely, the coefficient of determination (R2-value), mean absolute error (MAE), and root mean square error (RMSE), are used to evaluate and compare the performances of the different ML techniques. Based upon the experimental dataset, the SVM technique was observed to yield the lowest error rates-with the RMSE being 2.09 × 10-4 and MAE being 2 × 10-4 for COF and for SWR, an RMSE of 2 × 10-4 and MAE of 1.6 × 10-4 were obtained-and highest R2-values of 0.9999 for COF and 0.9998 for SWR. The observed performance metrics shows the SVM as the most reliable technique in predicting the tribological properties-with an accuracy of 99.99% for COF and 99.98% for SWR-of the polymer composites.

10.
Polymers (Basel) ; 15(20)2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37896355

RESUMO

In recent years, additive manufacturing technology, particularly in plastic component fabrication, has gained prominence. However, fundamental modelling of the influence of materials like ABS, PC, and PLA on tribological properties in fused deposition modeling (FDM) remains scarce, particularly in non-lubricated, oil-lubricated, and grease-lubricated modes. This experimental study systematically investigates the effects of material type, lubrication method, layer thickness, and infill density on FDM component tribology. A tribology analysis is conducted using a TRB3 tribometer. The results indicate a coefficient of friction (CoF) range between 0.04 and 0.2, generally increasing and decreasing with layer thickness and filler density. The lubrication impact hinges on the material surface texture. The study models the intricate relationships between these variables via full-factor analysis, showing a strong alignment between the modelled and measured friction coefficients (an average error of 3.83%). Validation tests on different materials affirm the model's reliability and applicability.

11.
J Mech Behav Biomed Mater ; 146: 106095, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37678105

RESUMO

Recently, researchers have been attempting to enhance the mechanical and tribological characteristics of thermosetting epoxy composites by incorporating inorganic nanoparticles and ensuring their uniform distribution throughout the matrix. This study characterises ball-milled ilmenite (FeTiO3-size of 63 nm) and silicon dioxide (SiO2-size of 67.5 nm) fillers added to epoxy in proportions of 0:0, 2.5:2.5, 5:5, and 7.5:7.5% by weight. A liquid ultrasonic technique is used to blend the fillers with the epoxy, and compression moulding is used to fabricate the composite. Mechanical tests were performed based on ASTM standards. Tensile strength, tensile modulus, flexural strength, flexural modulus and elongations at break(tensile and flexural test) of 5:5 wt % are 30.54%, 12.2%, 32.22%, 28.98%,23.78% and 23.53% higher than neat sample respectively. Shore "D" hardness and Izod's impact strength are 4.65% and 98.93% higher at 5:5 wt % than neat sample respectively. Specific wear rate decreased from 2.6 × 10-11 m3/Nm (neat GFRP: 0 wt % glass fibre reinforced polymer composite) to 0.7 × 10-11 m3/Nm at 5:5 wt % filler. Nanoparticles lowered the coefficient of friction by around 16.66%, 60.42%, and 33.33% at sliding distances of 100 m for 2.5:2.5, 5:5, and 7.5:7.5 wt % respectively with the neat sample. A 5:5 wt percent resulted in 76.68% less wear volume loss than pure GFRP. Field emission scanning electron microscopy (FESEM) analysis revealed element distributions, particle size, pullout of fibers, damaged interfaces, filler dispersion, voids, wear debris, interfacial debonding, and cavities. Thus, this approach enhances GFRP composite's mechanical, tribological, and structural properties.


Assuntos
Resinas Epóxi , Dióxido de Silício , Resistência à Flexão
12.
Polymers (Basel) ; 15(15)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37571160

RESUMO

This paper addresses peculiarities in the formation and adherence of a tribofilm on the wear track surface of antifriction PI- and PEI-based composites, as well as a transfer film (TF) on a steel counterface. It is shown that during hot pressing, PTFE nanoparticles melted and coalesced into micron-sized porous inclusions. In the PEI matrix, their dimensions were much larger (up to 30 µm) compared to those in the PI matrix (up to 6 µm). The phenomenon eliminated their role as effective uniformly distributed nanofillers, and the content of 5 wt.% was not always sufficient for the formation of a tribofilm or a significant decrease in the WR values. At the loaded content, the role of MoS2 and graphite (Gr) microparticles was similar, although filling with MoS2 microparticles more successfully solved the problem of adhering to a PTFE-containing tribofilm in the point tribological contact. This differed under the linear tribological contact. The higher roughness of the steel counterpart, as well as the larger area of its sliding surface with the same PTFE content in the three-component PI- and PEI-based composites, did not allow for a strong adherence of either the stable PTFE-containing tribofilm on the wear track surface or the TF on the steel counterpart. For the PEI-based composites, the inability to shield the steel counterpart from the more reactive polymer matrix, especially under the conditions of PTFE deficiency, was accompanied by multiple increases in the WR values, which were several times greater than that of neat PEI.

13.
Polymers (Basel) ; 15(12)2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37376379

RESUMO

Tribo-mechanical experiments were performed on Glass Fiber Reinforced Polymer (GRFP) composites against different engineering materials, and the tribological behavior of these materials under dry conditions was investigated. The novelty of this study consists of the investigation of the tribomechanical properties of a customized GFRP/epoxy composite, different from those identified in the literature. The investigated material in the work is composed of 270 g/m2 fiberglass twill fabric/epoxy matrix. It was manufactured by the vacuum bag method and autoclave curing procedure. The goal was to define the tribo-mechanical characteristics of a 68.5% weight fraction ratio (wf) of GFRP composites in relation to the different categories of plastic materials, alloyed steel, and technical ceramics. The properties of the material, including ultimate tensile strength, Young's modulus of elasticity, elastic strain, and impact strength of the GFPR, were determined through standard tests. The friction coefficients were obtained using a modified pin-on-disc tribometer using sliding speeds ranging from 0.1 to 0.36 m s-1, load 20 N, and different counter face balls from Polytetrafluoroethylene (PTFE), Polyamide (Torlon), 52,100 Chrome Alloy Steel, 440 Stainless Steel, and Ceramic Al2O3, with 12.7 mm in diameter, in dry conditions. These are commonly used as ball and roller bearings in industry and for a variety of automotive applications. To evaluate the wear mechanisms, the worm surfaces were examined and investigated by a Nano Focus-Optical 3D Microscopy, which uses cutting-edge µsurf technology to provide highly accurate 3D measurements of surfaces. The obtained results constitute an important database for the tribo-mechanical behavior of this engineering GFRP composite material.

14.
Materials (Basel) ; 16(11)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37297266

RESUMO

Surface composites are viable choices for various applications in the aerospace and automotive industries. Friction Stir Processing (FSP) is a promising method for fabricating surface composites. Aluminum Hybrid Surface Composites (AHSC) are fabricated using the FSP to strengthen a hybrid mixture prepared with equal parts of Boron carbide (B4C), Silicon Carbide (SiC), and Calcium Carbonate (CaCO3) particles. Different hybrid reinforcement weight percentages (reinforcement content of 5% (T1), 10% (T2), and 15% (T3)) were used in fabricating AHSC samples. Furthermore, different mechanical tests were performed on hybrid surface composite samples with different weight percentages of the reinforcements. Dry sliding wear assessments were performed in standard pin-on-disc apparatus as per ASTM G99 guidelines to estimate wear rates. The presence of reinforcement contents and dislocation behavior was investigated using Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM) studies. The results indicated that the Ultimate Tensile Strength (UTS) of sample T3 exhibited 62.63% and 15.17% higher than that of samples T1 and T2, respectively, while the Elongation (%) of T3 exhibited 38.46% and 15.38% lower than that of samples T1 and T2, respectively. Moreover, it was found that the hardness of sample T3 increased in the stir zone compared to samples T1 and T2, owing to its higher brittle response. The higher brittle response of sample T3 compared to samples T1 and T2 was confirmed by the higher value of Young's modulus and the lower value of Elongation (%).

15.
Heliyon ; 9(5): e15934, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37206042

RESUMO

Natural fiber-reinforced polymer matrix composites are gathering significance in future trend applications such as automotive, aerospace, sport, and other engineering applications due to their superior enhanced mechanical, wear, and thermal properties. Compared to synthetic fiber, natural fiber is low adhesive and flexural strength properties. The research aims to synthesize the epoxy hybrid composites by utilizing the silane (pH = 4) treated Kenaf (KF) and sisal fiber (SF) as layering by uni, bi, and multi-unidirectional via hand layup techniques. Thirteen composite samples have been prepared by three-layer formation adopted with different weight ratios of E/KF/SF such as 100E/0KF/0SF, 70E/30KF/0SF, 70E/0KF/30SF, 70E/20KF/10SF, and 70E/10KF/20SF respectively. The effect of layer formation on the tensile, flexural, and impact strength of composites is studied by ASTM D638, D790, and D256 standards. The unidirectional fiber layer formed (sample 5) 70E/10KF/20SF composite is found maximum tensile and flexural strength of 57.9 ± 1.2 MPa and 78.65 ± 1.8 MPa. This composite is subjected to wear studies by pin-on-disc wear apparatus configured with a hardened grey cast-iron plate under an applied load of 10, 20, 30, and 40 N at different sliding velocities of 0.1, 0.3, 0.5, and 0.7 m/s. The wear rate of the sample progressively increases with increasing load and sliding speed of the composite. The minimum wear rate of 0.012 mg/min (sample 4) is found on 7.6 N frictional force at 0.1 m/s sliding speed. Moreover, sample 4 at a high velocity of 0.7 m/s with a low load (10 N) shows a wear rate of 0.034 mg/min. The wear-worn surface is examined and found adhesive and abrasive wear on a high frictional force of 18.54 N at 0.7 m/s. The enhanced mechanical and wear behavior of sample 5 is recommended for automotive seat frame applications.

16.
Materials (Basel) ; 16(6)2023 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-36984300

RESUMO

Dental decay still presents a major health problem among children. Its treatment usually requires the use of stainless steel crowns. This study compares the wear behavior of 316 L stainless steel and polyetheretherketone (PEEK) composite under identical test conditions. The wear tests were conducted in a reciprocating ball-on-plate tribometer (Plint TE67/R) using alumina balls as a counterface and artificial saliva as a lubricant at 37 °C to faithfully mimic oral conditions. The coefficient of friction (COF) and specific wear rate (k) values were determined and SEM/EDS examinations were performed to identify the predominant wear mechanisms. Results showed that PEEK exhibited a significantly lower coefficient of friction (COF = 0.094 ± 0.004) and thus lower wear volume (ΔV = 0.0078 ± 0.0125 mm3) and higher wear resistance, with an average value of specific wear rate of k = 9.07 × 10-6 mm3N-1m-1 when compared to stainless steel (COF = 0.32 ± 0.03, ΔV = 0.0125 ± 0.0029 mm3, k = 1.45 × 10-5 mm3N-1m-1). PEEK was revealed to be a potential material for use in pediatric crowns due to its high wear resistance while overcoming the disadvantages associated with steel at both an aesthetic and biological level.

17.
Polymers (Basel) ; 15(6)2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36987121

RESUMO

In this work, the mechanical and tribological characteristics of polyetheretherketone (PEEK) sheets were enhanced by electron beam irradiation. PEEK sheets irradiated at a speed of 0.8 m/min with a total dose of 200 kGy achieved the lowest specific wear rate of 4.57 ± 0.69 (10-6 mm3/N-1m-1), compared to unirradiated PEEK with a rate of 13.1 ± 0.42 (10-6 mm3/N-1m-1). Exposure to an electron beam at 9 m/min for 30 runs, with a dose of 10 kGy per run for a total dose of 300 kGy, resulted in the highest improvement in microhardness, reaching 0.222 GPa. This may be due to the decrease in crystallite size, as indicated by the broadening of the diffraction peaks in the irradiated samples. According to the results of thermogravimetric analysis, the degradation temperature of the irradiated samples remained unchanged at 553 ± 0.5 °C, except a sample irradiated at dose 400 kGy, where the degradation temperature shifted towards a lower position of 544 ± 0.5 °C. Differential scanning calorimetry results revealed that the melting temperature (Tm) of the unirradiated PEEK was about 338 ± 0.5 °C, while a high temperature shift of the Tm was observed for the irradiated samples.

18.
Micron ; 168: 103429, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36841116

RESUMO

In the present article, a microscopic investigation was done on the effect of adding nano-clay-particles into the aluminum matrix on the wear behaviors of piston aluminum-silicon alloy under various forces and speeds. Then, the variation of the wear rate and the coefficient of friction (CoF) of the alloys was reported alongside the behavior of nano-reinforced composites. For this objective, the reciprocating wear tests were conducted under different conditions. Then, in order to evaluate the microstructural changes of the sample after the addition of the nano-clay-particles, optical and field-emission scanning electron microscopies (FESEM) were utilized. The obtained results demonstrated that the nano-reinforcement had an improvement in the wear behavior of the aluminum alloy. Furthermore, lower values of the CoF and wear rates were observed in the experiments, with lower normal forces or higher speeds.

19.
Materials (Basel) ; 16(4)2023 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-36837096

RESUMO

With an expectation of an increased number of revision surgeries and patients receiving orthopedic implants in the coming years, the focus of joint replacement research needs to be on improving the mechanical properties of implants. Head-stem trunnion fixation provides superior load support and implant stability. Fretting wear is formed at the trunnion because of the dynamic load activities of patients, and this eventually causes the total hip implant system to fail. To optimize the design, multiple experiments with various trunnion geometries have been performed by researchers to examine the wear rate and associated mechanical performance characteristics of the existing head-stem trunnion. The objective of this work is to quantify and evaluate the performance parameters of smooth and novel spiral head-stem trunnion types under dynamic loading situations. This study proposes a finite element method for estimating head-stem trunnion performance characteristics, namely contact pressure and sliding distance, for both trunnion types under walking and jogging dynamic loading conditions. The wear rate for both trunnion types was computed using the Archard wear model for a standard number of gait cycles. The experimental results indicated that the spiral trunnion with a uniform contact pressure distribution achieved more fixation than the smooth trunnion. However, the average contact pressure distribution was nearly the same for both trunnion types. The maximum and average sliding distances were both shorter for the spiral trunnion; hence, the summed sliding distance was approximately 10% shorter for spiral trunnions than that of the smooth trunnion over a complete gait cycle. Owing to a lower sliding ability, hip implants with spiral trunnions achieved more stability than those with smooth trunnions. The anticipated wear rate for spiral trunnions was 0.039 mm3, which was approximately 10% lower than the smooth trunnion wear rate of 0.048 mm3 per million loading cycles. The spiral trunnion achieved superior fixation stability with a shorter sliding distance and a lower wear rate than the smooth trunnion; therefore, the spiral trunnion can be recommended for future hip implant systems.

20.
Arch Orthop Trauma Surg ; 143(9): 5957-5965, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36802237

RESUMO

INTRODUCTION: Dual mobility implants have been successful in reducing postoperative hip dislocation but mid-term results of cup migration and polyethylene wear are missing in the literature. Therefore, we measured migration and wear at 5-year follow-up using radiostereometric analysis (RSA). MATERIALS AND METHODS: A cohort of 44 patients (mean age 73, 36 female) with heterogeneous indications for hip arthroplasty but all with a high risk of hip dislocation received total hip replacement (THA) with The Anatomic Dual Mobility X3 monoblock acetabular construct and a highly crosslinked polyethylene liner. RSA images and Oxford Hip Scores were obtained perioperatively and 1, 2, and 5 years postoperatively. Cup migration and polyethylene wear were calculated using RSA. RESULTS: Mean 2-year proximal cup translation was 0.26 mm (95% CI 0.17; 0.36). Proximal cup translation was stable from 1- to 5-year follow-up. Mean 2-year cup inclination (z-rotation) was 0.23° (95% CI - 0.22; 0.68) and was greater in patients with osteoporosis compared to patients without osteoporosis (p = 0.04). Using 1-year follow-up as baseline, the 3D polyethylene wear rate was 0.07 mm/year (0.05; 0.10). Oxford hip scores improved 19 (95% CI 14; 24) points from mean 21 (range 4; 39) at baseline, to 40 (9; 48) 2 years postoperatively. There were no progressive radiolucent lines > 1 mm. There was 1 revision for offset correction. CONCLUSIONS: Anatomic Dual Mobility monoblock cups were well-fixed, the polyethylene wear rate was low, and the clinical outcomes were good until 5-year follow-up suggesting good implant survival in patients of different age groups and with heterogeneous indications for THA.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Humanos , Feminino , Polietileno , Luxação do Quadril/cirurgia , Falha de Prótese , Desenho de Prótese , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Seguimentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA