Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
IEEE Sens J ; 24(12): 19000-19006, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-39429982

RESUMO

Direct conversion X-ray detectors offer high spatial resolution and improved sensitivity over indirect conversion detectors. As interest increases in their applications, including utilization as the top layer in dual-layer detectors for polyenergetic X-ray detection, additional studies on fabrication techniques are required. Amorphous selenium is a well-studied high-Z semiconductor capable of high-resolution and high-sensitivity imaging in direct architectures. It is already commercially available for mammography, and much work has gone into developing it for higher-energy applications (>20 keV.) To fully attenuate energies required for the low energy (<35 keV) top layer in dual-layer detectors, a-Se thicknesses greater than 200 µm must be fabricated. However, evaporation crucibles have limited capacity and require reloading of crucible material to achieve higher thicknesses, which is performed by opening the chamber and breaking vacuum mid-fabrication. We investigate the effects of splitting the fabrication into two depositions - exposing the sample to air in between - on device performance. We find that there is no significant effect on the transport properties, and a small range of performance parameters can be found - suggesting small fluctuations between devices of ± 5%, independent of fabrication technique and thickness. This implies that as we increase our thicknesses to those required for the low-energy layer of the dual-layer detector, we can expect performance to be maintained.

2.
Front Chem ; 12: 1459477, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39185370

RESUMO

Introduction: The process of laser-induced breakdown of amorphous and crystalline selenium nanoparticles (Se NPs) of various shapes during nanosecond laser fragmentation of aqueous colloidal solutions of nanoparticles with different concentrations has been studied. Methods: The methods of studying the characteristics of plasma and acoustic oscillations induced by optical breakdown are applied. The methods of assessing the concentration of hydrogen peroxide and hydroxyl radicals, the amount of long-lived reactive species of protein and 8-oxoguanine are applied. Results: It has been established that in the process of laser fragmentation of selenium nanoparticles at a wavelength of 532 nm, corresponding to the maximum absorption of selenium, the highest probability of breakdown, the number of plasma flashes, their luminosity and the amplitude of acoustic signals are achieved at concentrations of the order of 109 NPs/mL. It has been shown that the use of selenium nanoparticles of various shapes and structures leads to a change in the photoacoustic signal during laser-induced breakdown. When crystalline selenium nanoparticles are irradiated, the intensity of the photoacoustic response during breakdown turns out to be greater (1.5 times for flash luminosity and 3 times for acoustics) than when amorphous particles are irradiated at the same concentration. It has been shown that selenium nanoparticles exhibit significant antioxidant properties. Selenium nanoparticles effectively prevent the formation of reactive oxygen species (ROS) during water radiolysis, eliminate radiation-induced long-lived reactive species of protein, and reduce the radiation-chemical yield of a key marker of oxidative DNA damage - 8-oxoguanine. Discussion: In general, the intensity of processes occurring during laser fragmentation of amorphous and crystalline selenium nanoparticles differs significantly. The antioxidant properties are more pronounced in amorphous selenium nanoparticles compared to crystalline selenium nanoparticles.

3.
Sci Total Environ ; 951: 175698, 2024 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-39179046

RESUMO

Nitrogen oxides are inevitable hazardous components in coal-fired flue gas. This study designed a series of experiments and combined theoretical calculations to systematically investigate the effect of NOx on the removal of element mercury (Hg0) by nano-amorphous selenium (nano-a-Se). It was found that the impact of NOx on the removal of Hg0 by nano-a-Se primarily involves two mechanisms: competitive adsorption between NOx and Hg0, and the induced reduction effect of NOx on chemisorbed mercury (HgSe). NO inhibits the removal of Hg0 by nano-a-Se, and competitive adsorption is identified as the main influencing factor. Whereas the inhibitory effect of NO2 on the adsorption of Hg0 by nano a-Se can be counteracted due to its oxidizing effect on Hg0. Therefore, although NO2 presents stronger competitiveness than NO in the competitive adsorption with Hg0, it still shows a promoting effect on Hg0 removal, with 50 ppm NO2 restoring 5.7 % of the Hg0 removal efficiency. Additionally, the mechanism of NOx-induced reduction of HgSe was investigated in detail. NO2 is more capable of inducing the reduction of Hg(II) from HgSe to Hg0. This study presents new insights into the underlying influence mechanism, which could provide valuable references for the application of other selenium-based adsorbents.

4.
IEEE Trans Electron Devices ; 71(1): 676-680, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38435715

RESUMO

Dual-layer detectors provide a low-cost solution to improved material decomposition and lesion differentiation in X-ray imaging, while eliminating motion artifacts from multiple exposures. Most designs utilize two indirect detectors with scintillators designed for low-energy and higher-energy detection and separated by a copper filter to harden the beam for high energy detection. To improve the performance of the bottom detector and lower dose requirements, we have previously proposed an alloyed amorphous selenium photodetector to achieve improved resolution and absorption at green wavelengths, better suited to high-performance scintillators such as CsI:Tl. In this work, we demonstrate a baseline prototype for the bottom layer-a continuous, large area 83 µm pixel pitch flat panel indirect detector with well-established amorphous selenium as the photodetector-and verify the architecture's performance and detector design. We characterize lag, noise-power spectrum, detective quantum efficiency, and modular transfer function of the detector, and show resolution up to 6 lp/mm when operated at an applied bias of 150 V. This provides a starting point for evaluating the alloyed selenium materials, and shows promise for this detector in the future dual-layer design.

5.
Eur J Pharmacol ; 955: 175874, 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37394029

RESUMO

Vascular dementia (VD) is one of the most common causes of dementia, taking account for about 20% of all cases. Although studies have found that selenium supplementation can improve the cognitive ability of Alzheimer's patients, there is currently no research on the cognitive impairment caused by VD. This study aimed to investigate the role and mechanism of Amorphous selenium nanodots (A SeNDs) in the prevention of VD. The bilateral common carotid artery occlusion (BCCAO) method was used to establish a VD model. The neuroprotective effect of A SeNDs was evaluated by Morris water maze, Transcranial Doppler TCD, hematoxylin-eosin (HE) staining, Neuron-specific nuclear protein (Neu N) staining and Golgi staining. Detect the expression levels of oxidative stress and Calcium-calmodulin dependent protein kinase II (CaMK II), N-methyl-D-aspartate receptor subunit NR2A, and postsynaptic dense protein 95 (PSD95). Finally, measure the concentration of calcium ions in neuronal cells. The results showed that A SeNDs could significantly improve the learning and memory ability of VD rats, restore the posterior arterial blood flow of the brain, improve the neuronal morphology and dendritic remodeling of pyramidal cells in hippocampal CA1 area, reduce the level of oxidative stress in VD rats, increase the expression of NR2A, PSD95, CaMK II proteins and reduce intracellular calcium ion concentration, but the addition of selective NR2A antagonist NVP-AAMO77 eliminated these benefits. It suggests that A SeNDs may improve cognitive dysfunction in vascular dementia rats by regulating the NMDAR pathway.


Assuntos
Demência Vascular , Selênio , Ratos , Animais , Demência Vascular/tratamento farmacológico , Demência Vascular/metabolismo , Selênio/farmacologia , Selênio/metabolismo , Receptores de N-Metil-D-Aspartato/metabolismo , Cálcio/metabolismo , Estresse Oxidativo , Hipocampo , Neurônios/metabolismo , Aprendizagem em Labirinto
6.
Sensors (Basel) ; 22(19)2022 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-36236227

RESUMO

The general fabrication process for stabilized amorphous selenium (a-Se) detectors is vacuum deposition. The evaporant alloy is typically selenium alloyed with 0.3-0.5%As to stabilize it against crystallization. During the evaporation, fractionation leads to the formation of a deposited film that is rich in As near the surface and rich in Se near the substrate. The As content is invariably not uniform across the film thickness. This paper examines the effect of non-uniform As content on the charge collection efficiency (CE). The model for the actual CE calculation is based on the generalized CE equation under small signals; it involves the integration of the reciprocal range-field product (the schubweg) and the photogeneration profile. The data for the model input were extracted from the literature on the dependence of charge carrier drift mobilities and lifetimes on the As content in a-Se1-xAsx alloys to generate the spatial variation of hole and electron ranges across the photoconductor film. This range variation is then used to calculate the actual CE in the integral equation as a function of the applied field. The carrier ranges corresponding to the average composition in the film are also used in the standard CE equation under uniform ranges to examine whether one can simply use the average As content to calculate the CE. The standard equation is also used with ranges from the spatial average and average inverse. Errors are then compared and quantified from the use of various averages. The particular choice for averaging depends on the polarity of the radiation-receiving electrode and the spatial variation of the carrier ranges.

7.
Eur J Pharmacol ; 932: 175235, 2022 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-36049560

RESUMO

In clinic, there is still no unified standard for the treatment of non-alcoholic fatty liver disease (NAFLD), and the development of effective novel drugs to alleviate NAFLD remains a challenge. This study aimed to explore the effect and mechanism of amorphous selenium nanodots (A SeNDs) in alleviating NAFLD. Model rats with NAFLD were induced by the high-fat diet (HFD). Histomorphology was used to observe liver tissue, automatic biochemical analyzer was used to analyze liver function indicators, and ELISA kit was used to detect the effect of A SeNDs on oxidative stress and inflammatory factors in NAFLD rats. The results exhibited that A SeNDs could reduce hepatocyte steatosis, liver index, blood lipid level, and transaminase level in NAFLD rats. Furthermore, A SeNDs could relieve the oxidative stress and inflammatory reaction and maintain liver tissue structure in NAFLD rats. Mechanistically, A SeNDs (0.3 mg/kg/day) inhibit the phosphorylation of JNK/p38 MAPK pathways after activating vascular endothelial growth factor receptor 1 (VEGFR1) in the liver of rats with NAFLD to allay oxidative stress and inflammatory response and improves hepatic structure and liver function. Therefore, it should be an important method to mitigate NAFLD by supplementing A SeNDs to normalize hepatic structure and liver function.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Selênio , Animais , Dieta Hiperlipídica/efeitos adversos , Lipídeos , Fígado , Hepatopatia Gordurosa não Alcoólica/metabolismo , Fosforilação , Ratos , Selênio/metabolismo , Selênio/farmacologia , Transdução de Sinais/fisiologia , Transaminases/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo , Receptor 1 de Fatores de Crescimento do Endotélio Vascular/metabolismo , Proteínas Quinases p38 Ativadas por Mitógeno/metabolismo
8.
Sensors (Basel) ; 22(15)2022 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-35957449

RESUMO

In this work, we investigate the potential of employing a direct conversion integration mode X-ray detector with micron-scale pixels in two different X-ray phase-contrast imaging (XPCi) configurations, propagation-based (PB) and edge illumination (EI). Both PB-XPCi and EI-XPCi implementations are evaluated through a wave optics model-numerically simulated in MATLAB-and are compared based on their contrast, edge-enhancement, visibility, and dose efficiency characteristics. The EI-XPCi configuration, in general, demonstrates higher performance compared to PB-XPCi, considering a setup with the same X-ray source and detector. However, absorption masks quality (thickness of X-ray absorption material) and environmental vibration effect are two potential challenges for EI-XPCi employing a detector with micron-scale pixels. Simulation results confirm that the behavior of an EI-XPCi system employing a high-resolution detector is susceptible to its absorption masks thickness and misalignment. This work demonstrates the potential and feasibility of employing a high-resolution direct conversion detector for phase-contrast imaging applications where higher dose efficiency, higher contrast images, and a more compact imaging system are of interest.


Assuntos
Iluminação , Simulação por Computador , Radiografia , Raios X
9.
Med Phys ; 49(11): 6856-6870, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35997076

RESUMO

BACKGROUND: To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. PURPOSE: The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. METHODS: We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open-source GPU-accelerated Monte Carlo x-ray imaging simulation code (MC-GPU). We build on the previous version of the MC-GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)-approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x-ray photon till its first interaction within the x-ray detector. On the other hand, the signal spread in the x-ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron-hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth-dependent spread and collection of optical photons and relies on a pre-computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x-ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. RESULTS: We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. CONCLUSIONS: We have presented computational models of three commercially available FDA-approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC-GPU codes that can be used to replicate three systems are available in open source format through GitHub.


Assuntos
Mamografia , Humanos , Estados Unidos , Mamografia/métodos , Feminino
10.
J Phys Condens Matter ; 33(44)2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-34348254

RESUMO

Molecular dynamics simulations using a density functional description of energies and forces have been carried out for a model of an as-deposited (AD) surface of amorphous selenium. The deposition model assumed the annealing (at 400 K) of layers of randomly located single atoms, followed by compression to the density used in earlier melt-quenched (MQ) simulations of amorphous Se, and by further annealing. The AD and MQ structures are predominantly twofold coordinated and similar, for example in the pair distribution functions, with notable differences: the AD structures have more defects (atoms with one and three neighbours), and the ring distributions differ. These differences are also reflected in the electronic structures of the AD and MQ samples, where the increased presence of defects in the former influences the Bader charges and the edge states of the band gap. The dominance of rings found in a previous simulation of AD structures is not found.

11.
Front Bioeng Biotechnol ; 9: 673327, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34249881

RESUMO

AIM: This study aimed to investigate the preventive effect and possible mechanism of amorphous selenium nanoparticles (A-SeQDs) on isocarbophos induced vascular dysfunction. METHODS: A-SeQDs was made by auto redox decomposition of selenosulfate precursor. Male rats were given isocarbophos (0.5 mg/kg/2 days) by intragastric administration for 16 weeks to induce vascular dysfunction. During the course, A-SeQDs (50 mg/kg/day) was added to the water from week 5. Then, the rats were killed to observe and test the influence of A-SeQDs on the vascular dysfunction induced by isocarbophos. Finally, human umbilical vein endothelial cells (HUVECs) were treated with 10% DMEM of isocarbophos (100 µM) for 5 days to detect the related indexes. Before the use of isocarbophos treatment, different drugs were given. RESULTS: A-SeQDs could reduce total carbon dioxide, MDA, VCAM-1, ICAM-1, IL-1, and IL-6 while increasing oxygen saturation, NO content, and SOD activity in rats. A-SeQDs also resulted in relatively normal vascular morphology, and the expression of sodium hydrogen exchanger 1 (NHE1) and caspase-3 decreased in rats. Furthermore, in HUVECs treated with isocarbophos, A-SeQDs maintained mitochondrial membrane potential, inhibited the cleaved caspase-3 expression, and released cytochrome c from mitochondria to cytosol. CONCLUSION: A-SeQDs can inhibit the apoptosis of HUVECs through the mitochondrial pathway, and effectively treat the impairment of vascular endothelial function caused by isocarbophos, which is NHE1-dependent.

12.
J Synchrotron Radiat ; 28(Pt 4): 1081-1089, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34212871

RESUMO

The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. The technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.

13.
Phys Med Biol ; 66(13)2021 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-33545696

RESUMO

For the first time, we propose using amorphous selenium (a-Se) as the photoconductive material for time-of-flight (TOF) detectors. Advantages of avalanche-modea-Se are having high fill factor, low excess noise due to unipolar photoconductive gain, band transport in extended states with the highest possible mobility, and negligible trapping. The major drawback ofa-Se is its poor single-photon time resolution and low carrier mobility due to shallow-traps, problems that must be circumvented for TOF applications. We propose a nanopattern multi-wella-Se detector (MWSD) to enable both impact ionization avalanche gain and unipolar time-differential (UTD) charge sensing in one device. Our experimental results show that UTD charge sensing in avalanche-modea-Se improves time-resolution by nearly 4 orders-of-magnitude. In addition, we used Cramér-Rao lower bound analysis and Monte Carlo simulations to demonstrate the viability of our MWSD for low statistics photon imaging modalities such as PET despite it being a linear-mode device. Based on our results, our device may achieve 100 ps coincidence time resolution in TOF PET with a material that is low cost and uniformly scalable to large area.


Assuntos
Selênio , Método de Monte Carlo , Tomografia por Emissão de Pósitrons
14.
ACS Appl Electron Mater ; 3(8): 3538-3546, 2021 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-35600494

RESUMO

Amorphous selenium (a-Se) with its single-carrier and non-Markovian, hole impact ionization process can revolutionize low-light detection and emerge to be a solid-state replacement to the vacuum photomultiplier tube (PMT). Although a-Se-based solid-state avalanche detectors can ideally provide gains comparable to PMTs, their development has been severely limited by the irreversible breakdown of inefficient hole blocking layers (HBLs). Thus, understanding of the transport characteristics and ways to control electrical hot spots and, thereby, the breakdown voltage is key to improving the performance of avalanche a-Se devices. Simulations using Atlas, SILVACO, were employed to identify relevant conduction mechanisms in a-Se-based detectors: space-charge-limited current, bulk thermal generation, Schottky emission, Poole-Frenkel activated mobility, and hopping conduction. Simulation parameters were obtained from experimental data and first-principle calculations. The theoretical models were validated by comparing them with experimental steady-state dark current densities in avalanche and nonavalanche a-Se detectors. To maintain bulk thermal generation-limited dark current levels in a-Se detectors, a high-permittivity noninsulating material is required to substantially decrease the electric field at the electrode/hole blocking layer interface, thus preventing injection from the high-voltage electrode. This, in turn, prevents Joule heating from crystallizing the a-Se layer, consequently avoiding early dielectric breakdown of the device.

15.
Proc Natl Acad Sci U S A ; 117(39): 24076-24081, 2020 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-32934146

RESUMO

Enhanced surface mobility is critical in producing stable glasses during physical vapor deposition. In amorphous selenium (a-Se) both the structure and dynamics of the surface can be altered when exposed to above-bandgap light. Here we investigate the effect of light on the properties of vapor-deposited a-Se glasses at a range of substrate temperatures and deposition rates. We demonstrate that deposition both under white light illumination and in the dark results in thermally and kinetically stable glasses. Compared to glasses deposited in the dark, stable a-Se glasses formed under white light have reduced thermal stability, as measured by lower density change, but show significantly improved kinetic stability, measured as higher onset temperature for transformation. While light induces enhanced mobility that penetrates deep into the surface, resulting in lower density during vapor deposition, it also acts to form more networked structures at the surface, which results in a state that is kinetically more stable with larger optical birefringence. We demonstrate that the structure formed during deposition with light is a state that is not accessible through liquid quenching, aging, or vapor deposition in the dark, indicating the formation of a unique amorphous solid state.

16.
J Med Imaging (Bellingham) ; 7(3): 033501, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32411813

RESUMO

Purpose: Monte Carlo simulations were used to evaluate the imaging properties of a composite direct-indirect active matrix flat-panel imager (AMFPI) with potentially more favorable tradeoffs between x-ray quantum efficiency and spatial resolution than direct or indirect AMFPIs alone. This configuration, referred to as a hybrid AMFPI, comprises a scintillator that is optically coupled to an a-Se direct AMFPI through a transparent electrode and hole blocking layer, such that a-Se acts as both a direct x-ray converter and an optical sensor. Approach: GEANT4 was used to simulate x-ray energy deposition, optical transport, and charge signal generation processes in various hybrid AMPFI configurations under RQA5 and RQA9 x-ray beam conditions. The Fujita-Lubberts-Swank method was used to quantify the impact of irradiation geometry, x-ray converter thicknesses, conversion gain of each layer, and x-ray cross talk between layers on detective quantum efficiency (DQE). Results: Each hybrid configuration had a greater DQE than its direct AMFPI layer alone. The DQE improvement was largest at low spatial frequencies in both front- and back-irradiation (BI) geometries due to increased x-ray quantum efficiency provided by the scintillator. DQE improvements persisted at higher frequencies in BI geometry due to preferential x-ray absorption in a-Se. Matching the x-ray-to-charge conversion gains of a hybrid AMFPI's direct and indirect detection layers affects its Swank factor and, thus, DQE(0). X-ray cross talk has a negligible impact on the DQE ( f ) of hybrid AMFPIs with sufficiently high optical quantum efficiency. Conclusion: An optimized hybrid AMFPI can achieve greater DQE performance than current direct or indirect AMFPIs.

17.
Med Phys ; 46(2): 505-516, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30488455

RESUMO

PURPOSE: One limitation of experimental techniques for quantifying resolution and noise in detectors is that the measurement is made in a region-of-interest (ROI). With theoretical modeling, these properties can be measured at a point, allowing for quantification of spatial anisotropy. This paper calculates nonstationary transfer functions for amorphous selenium (a-Se) detectors in breast imaging. We use this model to demonstrate the performance advantage of a "next-generation" tomosynthesis (NGT) system, which is capable of x-ray source motion with more degrees of freedom than a clinical tomosynthesis system. METHODS: Using Swank's formulation, the optical transfer function (OTF) and presampled noise power spectra (NPS) are determined based on the point spread function derived in Part 1. The modulation transfer function (MTF) is found from the normalized modulus of the OTF. To take into account the presence of digitization, the presampled NPS is convolved with a two-dimensional comb function, for which the period along each direction is the reciprocal of the detector element size. The detective quantum efficiency (DQE) is then determined from combined knowledge of the OTF and NPS. RESULTS: First, the model is used to demonstrate the loss of image quality due to oblique x-ray incidence. The MTF is calculated along various polar angles, corresponding to different orientations of the input frequency. The MTF is independent of the incidence angle if the polar angle is perpendicular to the ray incidence direction. However, along other polar angles, oblique incidence results in MTF degradation at high frequencies. The MTF degradation is most substantial along the ray incidence direction. Unlike the MTF, the normalized NPS (NNPS) is independent of the incidence angle. To measure the relative signal-to-noise, the DQE is also calculated. Oblique incidence yields high-frequency DQE degradation, which is more pronounced than the MTF degradation. This arises because the DQE is proportionate with the square of the MTF. Ultimately, this model is used to evaluate how the image quality varies over the detector area. For various projection images, we calculate the variation in the incidence angle over this area. With the NGT system, the source can be positioned in such a way that this variation is minimized, and hence the DQE exhibits less anisotropy. To achieve this improvement in the image quality, the source needs to have a component of motion in the posteroanterior (PA) direction, which is perpendicular to the conventional direction of source motion in tomosynthesis. CONCLUSIONS: In a-Se detectors, the DQE at high frequencies is degraded due to oblique incidence. The DQE degradation is more pronounced than the MTF degradation. This model is used to quantify the spatial variation in DQE over the detector area. The use of PA source motion is a strategy for minimizing this variation and thus improving the image quality.


Assuntos
Modelos Teóricos , Radiografia/instrumentação , Selênio , Raios X
18.
Med Phys ; 46(2): 494-504, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30488462

RESUMO

PURPOSE: In previous work, a theoretical model of the point spread function (PSF) for oblique x-ray incidence in amorphous selenium (a-Se) detectors was proposed. The purpose of this paper is to develop a complementary model that includes two additional features. First, the incidence angle and the directionality of ray incidence are calculated at each position, assuming a divergent x-ray beam geometry. This approach allows the non-stationarity of the PSF to be modeled. Second, this paper develops a framework that is applicable to a digital system, unlike previous work which did not model the presence of a thin-film transistor (TFT) array. METHODS: At each point on the detector, the incidence angle and the ray incidence direction are determined using ray tracing. Based on these calculations, an existing model for the PSF of the x-ray converter (Med Phys. 1995;22:365-374) is generalized to a non-stationary model. The PSF is convolved with the product of two rectangle functions, which model the sampling of the TFT array. The rectangle functions match the detector element (del) size in two dimensions. RESULTS: It is shown that the PSF can be calculated in closed form. This solution is used to simulate a digital mammography (DM) system at two x-ray energies (20 and 40 keV). Based on the divergence of the x-ray beam, the direction of ray incidence varies with position. Along this direction, the PSF is broader than the reference rect function matching the del size. The broadening is more pronounced with increasing obliquity. At high energy, the PSF deviates more strongly from the reference rect function, indicating that there is more blurring. In addition, the PSF is calculated along the polar angle perpendicular to the ray incidence direction. For this polar angle, the shape of the PSF is dependent upon whether the ray incidence direction is parallel with the sides of the detector. If the ray incidence direction is parallel with either dimension, the PSF is a perfect rectangle function, matching the del size. However, if the ray incidence direction is at an oblique angle relative to the sides of the detector, the PSF is not rectangular. These results illustrate the non-stationarity of the PSF. CONCLUSIONS: This paper demonstrates that an existing model of the PSF of a-Se detectors can be generalized to include the effects of non-stationarity and digitization. The PSF is determined in closed form. This solution offers the advantage of shorter computation time relative to approaches that use numerical methods. This model is a tool for simulating a-Se detectors in future work, such as in virtual clinical trials with computational phantoms.


Assuntos
Modelos Teóricos , Radiografia/instrumentação , Selênio , Raios X
19.
ACS Photonics ; 6(6): 1338-1344, 2019 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38665849

RESUMO

Ultrafast photodetection has traditionally been performed with crystalline photodetectors, which tend to suffer from low production yield, suboptimal detection efficiency, and operational limitations that restrict their potential applications. Amorphous selenium is a unique, disordered photosensing material in which carrier transport can be shifted entirely from localized to extended states where holes get hot, resulting in deterministic, non-Markovian impact ionization avalanche, causing selenium to exhibit characteristics similar to crystalline photoconductors. For the first time, we have fabricated a multiwell selenium detector using nanopillars that achieves both avalanche gain and unipolar time-differential charge sensing. We experimentally show how these features together improve selenium's temporal performance by nearly 4 orders of magnitude, allowing us to achieve picosecond timing jitter suitable for a variety of ultrafast applications. Such a detector would be a viable low-cost, high production yield alternative for picosecond photodetection and imaging.

20.
Materials (Basel) ; 11(3)2018 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-29498668

RESUMO

Amorphous selenium (a-Se) thin films with a thickness of 1200 nm were successfully fabricated by thermal evaporation at a low vacuum degree of 10-2 Pa. The structural properties involving phase and morphology showed that a-Se thin films could be resistant to 60 °C in air. Also, a transformation to polycrystalline Selenium (p-Se) was shown as the annealing temperature rose to 62 °C and 65 °C, with obvious changes in color and surface morphology. Moreover, as the a-Se transformed to p-Se, the samples' transmittance decreased significantly, and the band gap declined dramatically from 2.15 eV to 1.92 eV. Finally, the X-radiation response of a-Se was investigated as an important property, revealing there is a remarkable response speed of photogeneration current both X-ray on and X-ray off, with a requirement of only a very small electrical field.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA