Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 617
Filtrar
1.
APMIS ; 2024 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-39449634

RESUMO

Accurate detection of Helicobacter pylori and its antimicrobial resistance is essential for eradication of the infections. The aim of this study was to compare five different CE-IVD marked assays in detection of H. pylori from 268 clinical stool samples. Samples were considered positive for H. pylori when at least three of the five tests were positive. Amplified IDEIA Hp StAR (Oxoid) and Premier Platinum HpSA PLUS (Meridian Bioscience Inc.) assays showed sensitivity of 100% [95% CI (confidence interval): 87-100] and LIAISON® Meridian H. pylori SA (DiaSorin) of 83.3% (95% CI: 66-93). Specificities of the assays were 94.5% (95% CI: 91-97), 95.4%; (95% CI: 92-97), and 97.1% (95% CI: 94-99) respectively. Amplidiag® H. pylori + ClariR (Mobidiag) assay showed 93.3% (95% CI: 78-99) and Allplex™ H. pylori & ClariR Assay (Seegene Inc.) 36.7% (95% CI: 22-55) sensitivity, while specificity of both was 97.9% (95% CI: 95-99). The Amplidiag® and Allplex™ assays concordantly detected clarithromycin resistance in positive for H. pylori samples. The Amplidiag® assay showed the highest accuracy, namely 97.4% (95% CI: 95-99). These data provide helpful information for planning laboratory diagnostics of H. pylori and detection of clarithromycin resistance from stool samples.

2.
J Clin Epidemiol ; 176: 111547, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39357662

RESUMO

OBJECTIVES: To evaluate the design, conduct, and analysis of systematic reviews on the diagnostic accuracy of rapid antigen tests for SARS-CoV-2 during the COVID-19 pandemic. STUDY DESIGN AND SETTING: We did a methodological overview of systematic reviews on diagnostic test accuracy, exploring methodological rigor, risk of bias and potential factors of between-review variability. RESULTS: Of the 31 included reviews, 30 provided summary statistics for sensitivity and 29 for specificity. Summary sensitivities ranged from 56.2% to 91.1%, with a median of 71.5% (IQR 68.3%-76.6%) and a mean of 72.7% with a 7.2 SD. Reported summary specificity estimates were consistently high: median 99.5% (IQR 99%-99.9%) and a mean of 99.3% with a 0.9 SD. We found methodological shortcomings in the systematic reviews, with a majority showing critically low confidence in quality and a high risk of bias. CONCLUSION: Despite significant methodological flaws in the reviews, the diagnostic accuracy estimates for rapid antigen tests were characterized by a strong central tendency, highlighting the importance of large sample sizes and broad participant representation. This study suggests the need for further research in diagnostic test accuracy assessments of rigor and risk of bias in systematic reviews.

3.
Open Forum Infect Dis ; 11(9): ofae521, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39286034

RESUMO

Review of histoplasmosis and blastomycosis antigen testing for 39 patients hospitalized with these diseases found that there were significantly longer turnaround times between the time of specimen collection and receipt of positive test results among those patients who had worse outcomes.

4.
J Med Microbiol ; 73(9)2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39222071

RESUMO

Background. The COVID-19 pandemic demonstrated a need for robust SARS-CoV-2 test evaluation infrastructure to underpin biosecurity and protect the population during a pandemic health emergency.Gap statement. The first generation of rapid antigen tests was less accurate than molecular methods due to their inherent sensitivity and specificity shortfalls, compounded by the consequences of self-testing. This created a need for more accurate point-of-care SARS-CoV-2 detection methods.Aim. Here we present the lessons-learned during the COVID-19 emergency response in Western Australia including the detailed set-up, evaluation and operation of rapid antigen test in a state-run drive-through sample collection service during the COVID-19 pandemic after the strict border shutdown ended.Methods. We report a conformity assessment of a novel, second-generation rapid antigen test (Virulizer) comprising a technician-operated rapid lateral flow immunoassay with fluorescence-based detection.Results. The Virulizer rapid antigen test demonstrated up to 100% sensitivity (95% CI: 61.0-100%), 91.94% specificity (95% CI: 82.5-96.5%) and 92.65% accuracy when compared to a commercial PCR assay method. Wide confidence intervals in our series reflect the limits of small sample size. Nevertheless, the Virulizer assay performance was well-suited to point-of-care screening for SARS-CoV-2 in a drive-through clinic setting.Conclusion. The adaptive evaluation process necessary under changing pandemic conditions enabled assessment of a simple sample collection and point-of-care testing process, and showed how this system could be rapidly deployed for SARS-CoV-2 testing, including to regional and remote settings.


Assuntos
COVID-19 , Testes Imediatos , SARS-CoV-2 , Sensibilidade e Especificidade , Humanos , COVID-19/diagnóstico , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Imunoensaio/métodos , Austrália Ocidental/epidemiologia , Antígenos Virais/análise , Teste Sorológico para COVID-19/métodos , Teste para COVID-19/métodos , Fluorescência , Sistemas Automatizados de Assistência Junto ao Leito
5.
Heliyon ; 10(16): e36614, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39262946

RESUMO

The fluorescent antibody to membrane antigen (FAMA) test is the gold standard for measuring the immunity induced by varicella vaccines with high sensitivity and specificity. However, certain aspects of the FAMA test, such as time consumption, non-automation, and subjective interpretation by observers using fluorescence microscopy, are obstacles to handling large amounts of samples. To overcome these hurdles, flow cytometry was adopted to analyze and compare the flow FAMA titer with the classic FAMA titer. In addition, to save time in FAMA antigen preparation and reduce lot-to-lot variation, the stability of the FAMA antigen stored in liquid nitrogen was investigated. The FAMA test was performed on sera from 229 children, and antibody titers were analyzed using fluorescence microscopy (classic FAMA) and flow cytometry (flow FAMA). For comparison, glycoprotein enzyme immunoassay (gpEIA) titer was also measured. A strong correlation was found between the flow and classic FAMA titers, and the flow FAMA and gpEIA titers, with Pearson's r of 0.9316 and 0.8588, respectively. Between the classic FAMA and gpEIA titers, the Pearson's r value was 0.8156. The positive percent agreement, negative percent agreement, and area under the curve of the flow FAMA against classic FAMA were 95.0 %, 86.8 %, and 0.909, respectively. And those of the flow FAMA against gpEIA were 80.0 %, 87.6 %, and 0.838, respectively. The FAMA antigen stored in liquid nitrogen was stable for up to 12 months. Based on the above data, flow FAMA has the potential to be used as an alternative to classic FAMA. Moreover, pre-made FAMA antigen may reduce the preparation time and lot-to-lot variation of FAMA test.

6.
JMIR Public Health Surveill ; 10: e47416, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39190459

RESUMO

BACKGROUND: Point-of-care testing (POCT) generates intrinsically fast, inherently spatial, and immediately actionable results. Lessons learned in rural Cambodia and California create a framework for planning and mobilizing POCT with telehealth interventions. Timely diagnosis can help communities assess the spread of highly infectious diseases, mitigate outbreaks, and manage risks. OBJECTIVE: The aims of this study were to identify the need for POCT in Cambodian border provinces during peak COVID-19 outbreaks and to quantify geospatial gaps in access to diagnostics during community lockdowns. METHODS: Data sources comprised focus groups, interactive learners, webinar participants, online contacts, academic experts, public health experts, and officials who determined diagnostic needs and priorities in rural Cambodia during peak COVID-19 outbreaks. We analyzed geographic distances and transit times to testing in border provinces and assessed a high-risk province, Banteay Meanchey, where people crossed borders daily leading to disease spread. We strategized access to rapid antigen testing and molecular diagnostics in the aforementioned province and applied mobile-testing experience among the impacted population. RESULTS: COVID-19 outbreaks were difficult to manage in rural and isolated areas where diagnostics were insufficient to meet needs. The median transit time from border provinces (n=17) to testing sites was 73 (range 1-494) minutes, and in the high-risk Banteay Meanchey Province (n=9 districts), this transit time was 90 (range 10-150) minutes. Within border provinces, maximum versus minimum distances and access times for testing differed significantly (P<.001). Pareto plots revealed geospatial gaps in access to testing for people who are not centrally located. At the time of epidemic peaks in Southeast Asia, mathematical analyses showed that only one available rapid antigen test met the World Health Organization requirement of sensitivity >80%. We observed that in rural Solano and Yolo counties, California, vending machines and public libraries dispensing free COVID-19 test kits 24-7 improved public access to diagnostics. Mobile-testing vans equipped with COVID-19 antigen, reverse transcription polymerase chain reaction, and multiplex influenza A/B testing proved useful for differential diagnosis, public awareness, travel certifications, and telehealth treatment. CONCLUSIONS: Rural diagnostic portals implemented in California demonstrated a feasible public health strategy for Cambodia. Automated dispensers and mobile POCT can respond to COVID-19 case surges and enhance preparedness. Point-of-need planning can enhance resilience and assure spatial justice. Public health assets should include higher-quality, lower-cost, readily accessible, and user-friendly POCT, such as self-testing for diagnosis, home molecular tests, distributed border detection for surveillance, and mobile diagnostics vans for quick telehealth treatment. High-risk settings will benefit from the synthesis of geospatially optimized POCT, automated 24-7 test access, and timely diagnosis of asymptomatic and symptomatic patients at points of need now, during new outbreaks, and in future pandemics.


Assuntos
COVID-19 , Testes Imediatos , População Rural , Camboja/epidemiologia , Humanos , COVID-19/epidemiologia , COVID-19/diagnóstico , População Rural/estatística & dados numéricos , Teste para COVID-19/métodos , Acessibilidade aos Serviços de Saúde , Recursos em Saúde/provisão & distribuição
7.
Pediatric Health Med Ther ; 15: 273-278, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39155991

RESUMO

Background: Bacterial pneumonia caused by Streptococcus pneumoniae continues to be one of the most common medical conditions in the pediatric population under 5 years of age, sometimes requiring prolonged hospitalizations and high costs. The time period (3 to 7 days) from the collection of biological samples (ie nasal exudate, pharyngeal exudate, sputum, blood culture and various secretions) to the arrival of the results has been a much discussed issue. Thus, the use of a rapid diagnostic test for Streptococcus pneumoniae urinary antigen, which is easy to use, may lead after the result is known to a targeted therapeutic management and thus to a favorable prognosis of the disease for the patient. Methods: This case report presents the case of a 4 years and 5 months old patient diagnosed with invasive pneumococcal-associated pneumococcal infection in the context of SARS-COV2 infection. Results: The clinical course was slowly favorable with complications that required a long hospitalization. Conclusion: In conclusion, some rapid diagnostic techniques, clinician judgment and some prevention methods, such as vaccination, can improve a patient's quality of life. One prospect for the future would be the development of new vaccines covering other aggressive Streptococcus pneumoniae serotypes.

8.
Heliyon ; 10(15): e35325, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39170261

RESUMO

Rapid antigen test (RAT) is widely used for SARS-CoV-2 infection diagnostics. However, test sensitivity has decreased recently due to the emergence of the Omicron variant and its sublineages. Here we developed a panel of SARS-CoV-2 nucleocapsid protein (NP) specific mouse monoclonal antibodies (mAbs) and assessed their sensitivity and specificity to important SARS-CoV-2 variants. We identified seven mAbs that exhibited strong reactivity to SARS-CoV-2 variants and recombinant NP (rNP) by Western immunoblot or ELISA. Their specificity to SARS-CoV-2 was confirmed by negative or low reactivity to rNPs from SARS-CoV-1, MERS, and common human coronaviruses (HCoV-HKU1, HCoV-CO43, HCoV-NL63, and HCoV-229E). These seven mAbs were further tested by immunoplaque assay against selected variants of concern (VOCs), including two Omicron sublineages, and five mAbs (F461G13, F461G7, F459G7, F457G3, and F461G6), showed strong reactions, warranting further suitability testing for the development of diagnostic assay.

9.
J Biol Methods ; 11: e99010009, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38988498

RESUMO

The rapid identification SARS-CoV-2 virus has become the basis for the control of the COVID-19 outbreak. The rapid antigen tests for SARS-CoV-2 are quick, widely available, and inexpensive. Rapid antigen tests have gradually replaced the time-consuming and costly RT-PCR. Currently, although several RAT kits have been extensively used for the diagnosis of COVID-19, validity data are limited due to the inconsistent sensitivity and poor reproducibility. Meanwhile, WHO does not recommend specific commercial RAT kits. Therefore, it is crucial to establish a method to evaluate the effectiveness of different rapid antigen tests kits. This study aimed to develop an evaluation system for rapid antigen tests to provide an efficient and accurate technique for screening SARS-CoV-2 antigen detection kits. Given large number of rapid antigen tests kits available, this study only focused on those that are representative and commonely used in China. By minimzing biases through randomization, concealment, and blinding, we eventually found that the Test 1 had the lowest sensitivity and the Test VI had the highest sensitivity. This study provided an evaluation platform that can potentially serve as a reference for COVID-19 diagnostic strategies.

10.
Cureus ; 16(6): e63294, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39070382

RESUMO

Background and objective The coronavirus disease 2019 (COVID-19) pandemic has imposed a significant burden on healthcare systems worldwide. This highlights the need for simple, rapid, and affordable diagnostic tests that can serve as alternatives to the existing costly and demanding polymerase chain reaction (PCR) assay, especially in resource-limited countries like Ghana. In light of this, we aimed to assess the diagnostic efficacy of three COVID-19 rapid immunochromatographic antigen test kits vs. real-time reverse transcriptase-PCR (rRT-PCR). Methods This study evaluated the sensitivity and specificity of three COVID-19 rapid immunochromatographic antigen test kits: DG Rapid, SD Rapid, and SS Rapid. They were compared with the gold standard RT-PCR for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid antigen in 75 randomly selected archived nasopharyngeal samples. Results Of the 75 samples tested, 38 (50.7%) were positive and 37 (49.3%) were negative for SARS-CoV-2 RNA by rRT-PCR assay. No false positives were recorded. On the other hand, the DG Rapid kit detected 30 (78.9%) true positives and eight (21.1%) false negatives. SD Rapid kit detected 28 (73.7%) true positives and 10 (26.3%) false negatives, while the SS Rapid kit detected 19 (50.0%) true positives and 19 (50.0%) false negatives. While the specificity of each test kit was 100% (95% CI), the sensitivity of the DG Rapid, SD Rapid, and SS Rapid kits was 79%, 74%, and 50% (95% CI), respectively. Higher sensitivities were recorded among samples with cycle threshold (Ct) values <29.99 for each kit. Also, the DG Rapid kit demonstrated 79% excellent agreement with rRT-PCR, while the SD Rapid and SS Rapid kits demonstrated good agreement with rRT-PCR with 73% and 50% Cohen's kappa values, respectively. Conclusions Based on our findings, DG Rapid and SD Rapid kits are reliable alternatives to rRT-PCR for the detection of SARS-CoV-2 infection, especially in resource-limited settings like Ghana.

11.
Diagn Microbiol Infect Dis ; 110(1): 116421, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38972132

RESUMO

We assessed the performance of three different multiplex lateral flow assays manufactured by SureScreen, Microprofit and Goldsite which provide results for influenza, respiratory syncytial virus (RSV) and SARS-CoV-2. Between 4 April and 20 October 2023, 1646 patients 6 months and older presenting to an outpatient department of a hospital in Hong Kong with ≥2 symptoms or signs of an acute respiratory illness were enrolled. The point estimates for all three multiplex tests had sensitivity >80% for influenza A and SARS-CoV-2 compared to PCR, and the tests manufactured by Microprofit and Goldsite had sensitivity >84% to detect RSV. Specificity was >97% for all three tests except for the SureScreen test which had specificity 86.2% (95% CI: 83.9% to 88.3%) for influenza A. Sensitivity was lower than reported by the manufacturers, resulting in a higher risk of false negatives. The three multiplex tests performed better in patients with high viral loads.


Assuntos
COVID-19 , Influenza Humana , SARS-CoV-2 , Sensibilidade e Especificidade , Humanos , COVID-19/diagnóstico , Pessoa de Meia-Idade , Influenza Humana/diagnóstico , Masculino , Feminino , Adulto , Idoso , Hong Kong , Adolescente , Pré-Escolar , Criança , Lactente , Adulto Jovem , Infecções por Vírus Respiratório Sincicial/diagnóstico , Idoso de 80 Anos ou mais , Infecções Respiratórias/diagnóstico , Infecções Respiratórias/virologia , Imunoensaio/métodos , Imunoensaio/normas , Vírus da Influenza A/isolamento & purificação
12.
Influenza Other Respir Viruses ; 18(7): e13305, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39053895

RESUMO

BACKGROUND: The COVID-19 pandemic underscored the need for rapid and accurate diagnostic tools. In August 2020, the Abbott BinaxNOW COVID-19 Antigen Card test became available as a timely and affordable alternative for SARS-CoV-2 molecular testing, but its performance may vary due to factors including timing and symptomatology. This study evaluates BinaxNOW diagnostic performance in diverse epidemiological contexts. METHODS: Using RT-PCR as reference, we assessed performance of the BinaxNOW COVID-19 test for SARS-CoV-2 detection in anterior nasal swabs from participants of two studies in Puerto Rico from December 2020 to May 2023. Test performance was assessed by days post symptom onset, collection strategy, vaccination status, symptomatology, repeated testing, and RT-PCR cycle threshold (Ct) values. RESULTS: BinaxNOW demonstrated an overall sensitivity of 84.1% and specificity of 98.8%. Sensitivity peaked within 1-6 days after symptom onset (93.2%) and was higher for symptomatic (86.3%) than asymptomatic (67.3%) participants. Sensitivity declined over the course of infection, dropping from 96.3% in the initial test to 48.4% in testing performed 7-14 days later. BinaxNOW showed 99.5% sensitivity in participants with low Ct values (≤ 25) but lower sensitivity (18.2%) for participants with higher Cts (36-40). CONCLUSIONS: BinaxNOW demonstrated high sensitivity and specificity, particularly in early-stage infections and symptomatic participants. In situations where test sensitivity is crucial for clinical decision-making, nucleic acid amplification tests are preferred. These findings highlight the importance of considering clinical and epidemiological context when interpreting test results and emphasize the need for ongoing research to adapt testing strategies to emerging SARS-CoV-2 variants.


Assuntos
COVID-19 , SARS-CoV-2 , Sensibilidade e Especificidade , Humanos , COVID-19/diagnóstico , Porto Rico/epidemiologia , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Masculino , Adulto , Feminino , Pessoa de Meia-Idade , Antígenos Virais/análise , Adulto Jovem , Adolescente , Teste Sorológico para COVID-19/métodos , Idoso , Teste para COVID-19/métodos
13.
J Virol Methods ; 329: 115000, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39038659

RESUMO

BACKGROUND/OBJECTIVES: We investigated if performing two lateral flow device (LFD) tests, LFD2 immediately after LFD1, could improve diagnostic sensitivity or specificity for detecting severe acute respiratory syndrome-related coronavirus 2 (SARS-CoV-2) antigen. STUDY DESIGN: Individuals aged ≥16 years attending UK community testing sites (February-May 2021) performed two successive LFD tests and provided a nose-and-throat sample for a polymerase chain reaction (PCR) test. Using the PCR result as the reference diagnosis, we assessed whether improvements could be achieved in sensitivity (by counting a positive result in either LFD as a positive overall test result) or specificity (by using LFD2 as confirmatory test). RESULTS: Overall, 2231 participants were included with 159 (7 %) having a positive PCR test. Of 2223 participants who completed both LFD tests, LFD results were highly concordant both with each other and with PCR tests (>97 %). The proportion of discord LFD results decreased significantly over the study period. Combined LFD usage achieved a sensitivity of 68.6 %, versus 67.1 % for either LFD individually. The specificity increased from 99.5 % to 99.8 % when using LFD2 as confirmatory test. Observed increases in sensitivity and specificity were not statistically significant. Void results were recorded for 31 (1.4 %) LFD1s, 19 (0.9 %) LFD2s and 6 (0.3 %) combined LFD tests. CONCLUSIONS: LFD tests were highly reproducible even when they were performed by untrained users following only written instructions and without supervision. While performing two LFD tests of the same type in quick succession marginally increased sensitivity or specificity, statistically significant improvements were not detected in our study.


Assuntos
Antígenos Virais , Teste Sorológico para COVID-19 , COVID-19 , SARS-CoV-2 , Sensibilidade e Especificidade , Humanos , COVID-19/diagnóstico , Adulto , SARS-CoV-2/imunologia , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Masculino , Feminino , Pessoa de Meia-Idade , Teste Sorológico para COVID-19/métodos , Antígenos Virais/análise , Adulto Jovem , Idoso , Adolescente , Reino Unido
14.
Open Forum Infect Dis ; 11(6): ofae304, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38911947

RESUMO

Background: Understanding changes in diagnostic performance after symptom onset and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) exposure within different populations is crucial to guide the use of diagnostics for SARS-CoV-2. Methods: The Test Us at Home study was a longitudinal cohort study that enrolled individuals across the United States between October 2021 and February 2022. Participants performed paired antigen-detection rapid diagnostic tests (Ag-RDTs) and reverse-transcriptase polymerase chain reaction (RT-PCR) tests at home every 48 hours for 15 days and self-reported symptoms and known coronavirus disease 2019 exposures immediately before testing. The percent positivity for Ag-RDTs and RT-PCR tests was calculated each day after symptom onset and exposure and stratified by vaccination status, variant, age category, and sex. Results: The highest percent positivity occurred 2 days after symptom onset (RT-PCR, 91.2%; Ag-RDT, 71.1%) and 6 days after exposure (RT-PCR, 91.8%; Ag-RDT, 86.2%). RT-PCR and Ag-RDT performance did not differ by vaccination status, variant, age category, or sex. The percent positivity for Ag-RDTs was lower among exposed, asymptomatic than among symptomatic individuals (37.5% (95% confidence interval [CI], 13.7%-69.4%) vs 90.3% (75.1%-96.7%). Cumulatively, Ag-RDTs detected 84.9% (95% CI, 78.2%-89.8%) of infections within 4 days of symptom onset. For exposed participants, Ag-RDTs detected 94.0% (95% CI, 86.7%-97.4%) of RT-PCR-confirmed infections within 6 days of exposure. Conclusions: The percent positivity for Ag-RDTs and RT-PCR tests was highest 2 days after symptom onset and 6 days after exposure, and performance increased with serial testing. The percent positivity of Ag-RDTs was lowest among asymptomatic individuals but did not differ by sex, variant, vaccination status, or age category.

15.
Vaccines (Basel) ; 12(6)2024 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-38932374

RESUMO

BACKGROUND: Community infections of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have increased rapidly since the emergence of the Omicron strain. During the eighth and ninth pandemic waves-when movement restrictions in the community were eased-the all-case registration system was changed, and the actual status of infection became uncertain. METHODS: We conducted regular rapid antigen tests (R-RATs) once or twice a week as self-testing to examine the actual state of coronavirus disease (COVID-19) diagnosis among healthcare employees. RESULTS: Overall, 320 (1.42/day) and 299 (1.76/day) employees were infected in the eighth and ninth pandemic waves. During both periods, 59/263 doctors (22.4%), 335/806 nurses (41.6%), 92/194 administrative employees (47.4%), and 129/218 clinical laboratory technicians (59.2%) were infected. In the eighth wave, 56 of 195 employees were infected through close contact; in the ninth wave, 26 of 62 employees were infected. No significant difference was observed in the number of vaccinations between infected and non-infected employees. The positivity rate of R-RATs was 0.41% and 0.45% in the eighth and ninth waves. R-RATs detected infection in 212 and 229 employees during the eighth and ninth waves, respectively; the ratio of R-RAT-detected positive employees to those who reported infection was significantly higher during the ninth wave (odds ratio: 1.67, 95% confidence interval: 1.17-2.37, p < 0.001). CONCLUSIONS: The number of infected healthcare employees remained high during the eighth and ninth pandemic waves in Japan. The R-RAT is considered effective for detecting mild or asymptomatic COVID-19 at an early stage and at a high rate in healthcare employees.

16.
Front Mol Biosci ; 11: 1308202, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38845778

RESUMO

Introduction: The global COVID-19 pandemic and seasonal influenza outbreaks have drawn attention to the critical need for accurate and efficient diagnostic tools. Methods: The performance of the InstaView COVID-19/Flu Ag Combo Test, which was designed to simultaneously detect the SARS-CoV-2, influenza A, and influenza B viruses, was analytically and clinically evaluated. Results: The InstaView COVID-19/Flu Ag Combo Test exhibited robust detection capabilities, accurately identifying SARS-CoV-2, influenza A, and influenza B viruses over a wide concentration range (1.41 × 103 to 7.05 × 104 TCID50/mL). Extensive testing against potential cross-reactants and interferences yielded no false-positive results, indicating the high specificity of the test. Clinical evaluation further confirmed the kit's reliability, with sensitivity ranging from 95.1% to 98.2% for SARS-CoV-2, 88.9%-95.2% for influenza A, and 91.7%-100% for influenza B depending on the sample type. The specificity was consistently 100% for all of the targeted viruses. Discussion: The InstaView COVID-19/Flu Ag Combo Test thus demonstrated high performance, ease of use, rapid results, and the ability to precisely detect SARS-CoV-2 and influenza A/B infections, making it an effective tool in streamlining diagnostic workflows, optimizing resource allocation, and improving patient outcomes.

17.
Cureus ; 16(5): e59979, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38854237

RESUMO

Legionnaires' disease is a potentially severe type of pneumonia most often caused by the organism Legionella pneumophila. Exposure to this bacterial pathogen typically happens in the community but may also occur in the hospital setting. This report describes the case of a patient who presented due to 10 days of fever, shortness of breath, and diarrhea, with initial imaging demonstrating multifocal pneumonia. The patient was appropriately started on empiric antibiotics for community-acquired pneumonia and admitted to the medicine floor. The patient showed no meaningful improvement in his initial hospital course on empiric antibiotics with continued oxygen requirements. Meanwhile, urine Legionella antigen testing returned positive on hospital day four, and after tailoring antibiotics accordingly, the patient's clinical status improved significantly. This case report highlights the efficacy of broad testing in the initial admission and the need for constant re-evaluation in the context of a patient not improving with appropriate therapy.

18.
Parasit Vectors ; 17(1): 258, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872227

RESUMO

BACKGROUND: Dirofilaria immitis, commonly known as heartworm (HW), is a parasitic nematode transmitted by various mosquito species, leading to heartworm disease (HWD) in dogs. Diagnosis of HW typically involves antigen or microfilariae detection, or visualization of adult worms through imaging or post mortem examination. Polymerase chain reaction (PCR) and micro RNA (miRNA) detection have been explored for HW diagnosis. METHODS: Three dogs, previously experimentally infected with HW, underwent blood sampling every 4 weeks for 7 months. Samples were assessed for antigen presence after heat treatment, PCR amplification, and microfilaria examination using Giemsa-stained thick smears. Additionally, whole blood aliquots underwent miRNA deep sequencing and bioinformatic analysis. RESULTS: Heartworm antigen was detectable after heat treatment at 20 weeks post-inoculation and via PCR at 24 weeks, with microfilariae observed in peripheral blood smears at 28 weeks. However, deep miRNA sequencing revealed that the miRNA candidate sequences are not consistently expressed before 28 weeks of infection. CONCLUSIONS: While ancillary molecular methods such as PCR and miRNA sequencing may be less effective than antigen detection for detecting immature larval stages in an early stage of infection, our experimental findings demonstrate that circulating miRNAs can still be detected in 28 weeks post-infection.


Assuntos
Dirofilaria immitis , Dirofilariose , Doenças do Cão , MicroRNAs , Animais , Dirofilaria immitis/genética , Dirofilaria immitis/isolamento & purificação , Cães , Dirofilariose/diagnóstico , Dirofilariose/parasitologia , MicroRNAs/sangue , MicroRNAs/genética , Doenças do Cão/parasitologia , Doenças do Cão/diagnóstico , Antígenos de Helmintos/sangue , Antígenos de Helmintos/genética , Diagnóstico Precoce , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase/veterinária , Microfilárias/isolamento & purificação , Microfilárias/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos
19.
J Immigr Minor Health ; 26(5): 866-877, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38822923

RESUMO

Prostate-specific antigen (PSA)-based prostate cancer screening is a preference-sensitive decision for which experts recommend a shared decision making (SDM) approach. This study aimed to examine PSA screening SDM in primary care. Methods included qualitative analysis of audio-recorded patient-provider interactions supplemented by quantitative description. Participants included 5 clinic providers and 13 patients who were: (1) 40-69 years old, (2) Black, (3) male, and (4) attending clinic for routine primary care. Main measures were SDM element themes and "observing patient involvement in decision making" (OPTION) scoring. Some discussions addressed advantages, disadvantages, and/or scientific uncertainty of screening, however, few patients received all SDM elements. Nearly all providers recommended screening, however, only 3 patients were directly asked about screening preferences. Few patients were asked about prostate cancer knowledge (2), urological symptoms (3), or family history (6). Most providers discussed disadvantages (80%) and advantages (80%) of PSA screening. Average OPTION score was 25/100 (range 0-67) per provider. Our study found limited SDM during PSA screening consultations. The counseling that did take place utilized components of SDM but inconsistently and incompletely. We must improve SDM for PSA screening for diverse patient populations to promote health equity. This study highlights the need to improve SDM for PSA screening.


Assuntos
Negro ou Afro-Americano , Tomada de Decisão Compartilhada , Detecção Precoce de Câncer , Atenção Primária à Saúde , Antígeno Prostático Específico , Neoplasias da Próstata , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/diagnóstico , Idoso , Adulto , Antígeno Prostático Específico/sangue , Gravação em Fita , Participação do Paciente , Relações Médico-Paciente , Pesquisa Qualitativa , Tomada de Decisões
20.
Intern Med ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38719598

RESUMO

Background A dedicated stool container is required for Helicobacter pylori stool antigen testing. If H. pylori fecal antigen can be measured from a fecal occult blood test container (S fecal collection container or S container), which is widely used for colorectal cancer screening, screening of the upper and lower gastrointestinal tract can be performed with a single stool sample. We investigated the clinical usefulness of an H. pylori stool antigen assay using an S container. Patients and Materials A total of 347 patients who underwent esophagogastroduodenoscopy (EGD) were included. After the procedure, H. pylori stool antigen was measured using the S container and collection container recommended for H. pylori stool antigen (BL-stool collection container or BL container), and the qualitative outcomes of each were compared. A bioluminescent enzyme immunoassay (BLEIA) was used to measure H. pylori stool antigen. Results The overall agreement between S containers and BL containers was 100% (347/347), indicating that the qualitative outcomes were equivalent. As a secondary analysis, the results of the S container samples were evaluated according to the diagnosis made by physicians, and the overall agreement rate was 99.7% (345/346), indicating a high correlation. Conclusion The detection of H. pylori stool antigen using the S container is clinically useful because the results are equivalent to those obtained by the usual method. Screening of the upper and lower gastrointestinal tract is expected to be possible with a single stool sample in the future.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA