Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 197
Filtrar
1.
Ann Med Surg (Lond) ; 86(9): 5058-5064, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39238999

RESUMO

Background: Electrocardiogram (EKG) is a commonly used diagnostic tool for the evaluation of the electrical activity of the heart. The purpose of this study was to assess the knowledge and interpretation proficiency of EKG among healthcare professionals (HCPs) in Pakistan. Methods: This prospective cross-sectional study was conducted among HCPs working in different healthcare settings. A structured questionnaire was used to assess the participants' theoretical knowledge and ability to interpret EKG findings. The data were analyzed using descriptive statistics and χ2 tests. The study indicates that EKG knowledge and interpretation proficiency among HCPs in Pakistan is unsatisfactory. The inadequacy of training periods of EKG training sessions and insufficient participation of HCPs in offered training opportunities put forward the need for the formation and introduction of better structured and efficient EKG training programmes. Results: A total of 511 HCPs participated in the study, 28% of whom reportedly had received formal training for EKG interpretation. About 80% of the participants correctly identified theoretical questions pertaining to EKG, while 58% of the participants were able to accurately interpret EKG findings, and most HCPs (69.9%) read fewer than ten EKGs per week. Conclusion: This study demonstrates a lack of expertise and a poor understanding of EKG in HCPs of Pakistan. The low level of EKG knowledge and interpretation proficiency among HCPs may lead to diagnostic errors and poor patient outcomes. Therefore, efforts should be made to improve EKG education and training among HCPs in Pakistan.

2.
J Innov Card Rhythm Manag ; 15(8): 5997-6003, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39193532

RESUMO

Telemetry monitoring (conventional cardiac monitoring system [CCMS]) is a universal method for postoperative arrhythmia detection; however, the clinical challenge of alarm fatigue, primarily associated with noise or cable disconnections, persists. The introduction of wireless continuous cardiac monitoring (WCCM) represents a potential solution to enhance recording fidelity. Patients were simultaneously outfitted with both a monitoring device considered the standard of care and a novel adhesive wireless patch. A 48-h cardiac monitoring session with the two devices occurred after cardiac surgery in a unit equipped with a telemetry system. A total of 53 patients with a mean age of 60 ± 17 years were included in the trial. The number of events detected by the two systems was significantly different at 190 versus 174 for the CCMS and the WCCM system, respectively (P < .05). However, the percentage of agreement was not significantly different at 91% versus 88% (P = .37). Events were classified as follows: pause (2 events, 1%), atrial or premature ventricular contractions (18 events, 11%), atrial flutter or fibrillation (76 events, 45%), bradycardia (12 events, 7%), and tachycardia (61 events, 36%). False alarms were significantly more frequent with the CCMS (n = 21) than with the WCCM system (n = 5; P = .002). The study successfully demonstrated the feasibility and usability of wireless monitoring for patients requiring telemetry. The overall results are compelling, as the WCCM system performed satisfactorily, achieving results comparable to those obtained with the CCMS, even with significantly fewer false alarms.

3.
Future Cardiol ; 20(10): 537-541, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39101435

RESUMO

Cabozantinib, a multi-kinase receptor inhibitor, is utilized in the treatment of advanced malignancies such as metastatic renal cancers. While rare, cabozantinib-induced cardiotoxicity has emerged as a recognized adverse effect with potentially reversible outcomes. We report the case of a 55-year-old male who developed fatal cardiomyopathy 4 months after initiating cabozantinib therapy. Despite its rarity, cardiomyopathy after initiation of cabozantinib can be lethal if not diagnosed early. This case underscores a significant gap in the surveillance of patients treated with newer agents like cabozantinib. Larger observational studies are needed to assess the prevalence and impact of cardiomyopathy after initiation of cabozantinib therapy, and to determine the cost-effectiveness of early surveillance protocols.


[Box: see text].


Assuntos
Anilidas , Carcinoma de Células Renais , Cardiomiopatias , Neoplasias Renais , Piridinas , Humanos , Piridinas/efeitos adversos , Piridinas/uso terapêutico , Masculino , Anilidas/efeitos adversos , Pessoa de Meia-Idade , Cardiomiopatias/induzido quimicamente , Cardiomiopatias/diagnóstico , Neoplasias Renais/tratamento farmacológico , Carcinoma de Células Renais/tratamento farmacológico , Carcinoma de Células Renais/secundário , Evolução Fatal , Inibidores de Proteínas Quinases/efeitos adversos , Antineoplásicos/efeitos adversos
4.
Acta Vet Hung ; 72(3): 178-185, 2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39172517

RESUMO

Potential arrhythmias recorded by cardiac monitors using the built-in human algorithm are as follows: total number of episodes, ventricular tachycardia, asystole, bradycardia, atrial tachycardia, atrial fibrillation and the percentage of time spent in atrial tachycardia or atrial fibrillation. Long-term use of an insertable cardiac monitor (loop recorder) has been reported in one horse earlier, but its accurate role as a diagnostic tool is still unclear. The aim of the present study was to investigate the long-term applicability of the Reveal XT cardiac monitor for recording cardiac arrhythmias in adult horses. The Reveal XT cardiac monitor was implanted in 12 horses under sedation in standing position. Median duration of data recording calculated for the population was 1,169 days. The number of false positive detections of asystole and bradycardia was extremely high in all horses. For atrial fibrillation, false positive detection occurred in five and false negative detection occurred in one horse. The present study showed that the long-term use of the Reveal XT cardiac monitor is feasible, well-tolerated and the devices work reliably, without complications. The human algorithm could not be used for automatic detection of arrhythmic episodes in the study population. The device could detect atrial fibrillation in horses, but the recorded AF burden was inaccurate and the stored ECGs had to be manually interpreted. Because the human analyser algorithm of this cardiac monitor fails to identify bradyarrhythmias in horses based on our results, this instrument is not capable for accurately determining the aetiology of episodic collapse in this species.


Assuntos
Arritmias Cardíacas , Doenças dos Cavalos , Animais , Cavalos , Doenças dos Cavalos/diagnóstico , Arritmias Cardíacas/veterinária , Arritmias Cardíacas/diagnóstico , Masculino , Feminino , Eletrocardiografia/veterinária , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/veterinária , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos
5.
Heart Rhythm O2 ; 5(7): 460-467, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39119022

RESUMO

Background: Single-shot devices are increasingly used for pulmonary vein isolation (PVI) in atrial fibrillation (AF). The Arctic Front cryoballoon is the most frequently used single-shot technology. A recently developed novel pulsed field ablation (PFA) device (FARAPULSE) has been introduced with the aim to improve procedural safety and efficacy. Objective: This study will compare the novel FARAPULSE PFA device and the Arctic Front cryoballoon for first PVI in patients with symptomatic paroxysmal AF. Methods: SINGLE SHOT CHAMPION is a multicenter, randomized controlled trial with blinded endpoint adjudication by an independent clinical events committee. Overall, 210 patients with paroxysmal AF undergoing their PVI are randomized 1:1 between PFA and cryoballoon ablation. Continuous rhythm monitoring with an implantable cardiac monitor is performed in all patients. Results: The primary endpoint is time to first recurrence of any atrial tachyarrhythmia (AF and/or organized atrial tachyarrhythmia) lasting ≥120 seconds and identified by the implantable cardiac monitor within 91 and 365 days postablation. The composite procedural safety endpoint includes cardiac tamponade requiring drainage, persistent phrenic nerve palsy, vascular complications requiring intervention, stroke/transient ischemic attack, atrioesophageal fistula, and death occurring during or up to 30 days after the procedure. Key secondary endpoints include (1) increase in high-sensitivity troponin on day 1 postablation, (2) analysis of postablation 3-dimensional electroanatomic mapping (first 25 patients per study group), (3) AF burden, and (4) quality-of-life changes. Conclusion: SINGLE SHOT CHAMPION will evaluate the efficacy and safety of PVI using the novel FARAPULSE PFA for patients with symptomatic paroxysmal AF.

6.
Heart Rhythm ; 21(9): 1562-1569, 2024 09.
Artigo em Inglês | MEDLINE | ID: mdl-38763376

RESUMO

BACKGROUND: Long-term clinical outcomes of catheter ablation (CA) compared to thoracoscopic surgical ablation (SA) to treat patients with long-standing persistent atrial fibrillation (LSPAF) are not known. OBJECTIVE: The purpose of this study was to compare the long-term (36-month) clinical efficacy, quality of life, and cost-effectiveness of SA and CA in LSPAF. METHODS: Participants were followed up for 3 years using implantable loop recorders and questionnaires to assess the change in quality of life. Intention-to-treat analyses were used to report the findings. RESULTS: Of the 115 patients with LSPAF treated, 104 (90.4%) completed 36-month follow-up [CA: n = 57 (95%); SA: n = 47 (85%)]. After a single procedure without antiarrhythmic drugs, 7 patients (12%) in the CA arm and 5 (11%) in the SA arm [hazard ratio 1.22; 95% confidence interval (CI) 0.81-1.83; P = .41] were free from atrial fibrillation/tachycardia (AF/AT) ≥30 seconds at 36 months. Thirty-three patients (58%) in the CA arm and 26 (55%) in the SA arm (hazard ratio 1.04; 95% CI 0.57-1.88; P = .91) had their AF/AT burden reduced by ≥75%. The overall impact on health-related quality of life was similar, with mean quality-adjusted life year estimates of 2.45 (95% CI 2.31-2.59) for CA and 2.32 (95% CI 2.13-2.52) for SA. Estimated costs were higher for SA (mean £24,682; 95% CI £21,746-£27,618) than for CA (mean £18,002; 95% CI £15,422-£20,581). CONCLUSION: In symptomatic LSPAF, CA and SA were equally effective at achieving arrhythmia outcomes (freedom from AF/AT ≥30 seconds and ≥75% burden reduction) after a single procedure without antiarrhythmic drugs. However, SA is significantly more costly than CA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Análise Custo-Benefício , Qualidade de Vida , Toracoscopia , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/economia , Masculino , Feminino , Ablação por Cateter/métodos , Ablação por Cateter/economia , Pessoa de Meia-Idade , Resultado do Tratamento , Toracoscopia/métodos , Toracoscopia/economia , Seguimentos , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia Ambulatorial/economia , Idoso , Fatores de Tempo
7.
Am J Emerg Med ; 81: 111-115, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38733663

RESUMO

BACKGROUND AND OBJECTIVES: Patient monitoring systems provide critical information but often produce loud, frequent alarms that worsen patient agitation and stress. This may increase the use of physical and chemical restraints with implications for patient morbidity and autonomy. This study analyzes how augmenting alarm thresholds affects the proportion of alarm-free time and the frequency of medications administered to treat acute agitation. METHODS: Our emergency department's patient monitoring system was modified on June 28, 2022 to increase the tachycardia alarm threshold from 130 to 150 and to remove alarm sounds for several arrhythmias, including bigeminy and premature ventricular beats. A pre-post study was performed lasting 55 days before and 55 days after this intervention. The primary outcome was change in number of daily patient alarms. The secondary outcomes were alarm-free time per day and median number of antipsychotic and benzodiazepine medications administered per day. The safety outcome was the median number of patients transferred daily to the resuscitation area. We used quantile regression to compare outcomes between the pre- and post-intervention period and linear regression to correlate alarm-free time with the number of sedating medications administered. RESULTS: Between the pre- and post-intervention period, the median number of alarms per day decreased from 1332 to 845 (-37%). This was primarily driven by reduced low-priority arrhythmia alarms from 262 to 21 (-92%), while the median daily census was unchanged (33 vs 32). Median hours per day free from alarms increased from 1.0 to 2.4 (difference 1.4, 95% CI 0.8-2.1). The median number of sedating medications administered per day decreased from 14 to 10 (difference - 4, 95% CI -1 to -7) while the number of escalations in level of care to our resuscitation care area did not change significantly. Multivariable linear regression showed a 60-min increase of alarm-free time per day was associated with 0.8 (95% CI 0.1-1.4) fewer administrations of sedating medication while an additional patient on the behavioral health census was associated with 0.5 (95% CI 0.0-1.1) more administrations of sedating medication. CONCLUSION: A reasonable change in alarm parameter settings may increase the time patients and healthcare workers spend in the emergency department without alarm noise, which in this study was associated with fewer doses of sedating medications administered.


Assuntos
Alarmes Clínicos , Serviço Hospitalar de Emergência , Agitação Psicomotora , Humanos , Masculino , Agitação Psicomotora/tratamento farmacológico , Feminino , Pessoa de Meia-Idade , Antipsicóticos/uso terapêutico , Antipsicóticos/administração & dosagem , Adulto , Idoso , Benzodiazepinas/uso terapêutico , Benzodiazepinas/administração & dosagem , Monitorização Fisiológica/métodos , Hipnóticos e Sedativos/uso terapêutico , Hipnóticos e Sedativos/administração & dosagem
8.
Diagnostics (Basel) ; 14(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38732339

RESUMO

The paper presents a system for analyzing cardiac activity with the possibility of continuous and remote monitoring. The created sensor mobile device monitors heart activity by means of the convenient and imperceptible registration of cardiac signals. At the same time, the behavior of the human body is also monitored through the accelerometer and gyroscope built into the device, thanks to which it is possible to signal in the event of loss of consciousness or fall (in patients with syncope). Conducting real-time cardio monitoring and the analysis of recordings using various mathematical methods (linear, non-linear, and graphical) enables the research, accurate diagnosis, timely assistance, and correct treatment of cardiovascular diseases. The paper examines the recordings of patients diagnosed with arrhythmia and syncope recorded by electrocardiography (ECG) sensors in real conditions. The obtained results are subjected to statistical analysis to determine the accuracy and significance of the obtained results. The studies show significant deviations in the patients with arrhythmia and syncope regarding the obtained values of the studied parameters of heart rate variability (HRV) from the accepted normal values (for example, the root mean square of successive differences between normal heartbeats (RMSSD) in healthy individuals is 24.02 ms, while, in patients with arrhythmia (6.09 ms) and syncope (5.21 ms), it is much lower). The obtained quantitative and graphic results identify some possible abnormalities and demonstrate disorders regarding the activity of the autonomic nervous system, which is directly related to the work of the heart.

9.
Physiol Meas ; 45(5)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38663430

RESUMO

Objective.The EPHNOGRAM project aimed to develop a low-cost, low-power device for simultaneous electrocardiogram (ECG) and phonocardiogram (PCG) recording, with additional channels for environmental audio to enhance PCG through active noise cancellation. The objective was to study multimodal electro-mechanical activities of the heart, offering insights into the differences and synergies between these modalities during various cardiac activity levels.Approach.We developed and tested several hardware prototypes of a simultaneous ECG-PCG acquisition device. Using this technology, we collected simultaneous ECG and PCG data from 24 healthy adults during different physical activities, including resting, walking, running, and stationary biking, in an indoor fitness center. The data were annotated using a robust software that we developed for detecting ECG R-peaks and PCG S1 and S2 components, and overseen by a human expert. We also developed machine learning models using ECG-based, PCG-based, and joint ECG-PCG features, like R-R and S1-S2 intervals, to classify physical activities and analyze electro-mechanical dynamics.Main results.The results show a significant coupling between ECG and PCG components, especially during high-intensity exercise. Notable micro-variations in S2-based heart rate show differences in the heart's electrical and mechanical functions. The Lomb-Scargle periodogram and approximate entropy analyses confirm the higher volatility of S2-based heart rate compared to ECG-based heart rate. Correlation analysis shows stronger coupling between R-R and R-S1 intervals during high-intensity activities. Hybrid ECG-PCG features, like the R-S2 interval, were identified as more informative for physical activity classification through mRMR feature selection and SHAP value analysis.Significance.The EPHNOGRAM database, is available on PhysioNet. The database enhances our understanding of cardiac function, enabling future studies on the heart's mechanical and electrical interrelationships. The results of this study can contribute to improved cardiac condition diagnoses. Additionally, the designed hardware has the potential for integration into wearable devices and the development of multimodal stress test technologies.


Assuntos
Eletrocardiografia , Processamento de Sinais Assistido por Computador , Humanos , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Fonocardiografia/instrumentação , Masculino , Adulto , Bases de Dados Factuais , Feminino , Fatores de Tempo , Adulto Jovem , Aprendizado de Máquina , Frequência Cardíaca/fisiologia
10.
Fetal Diagn Ther ; 51(4): 357-364, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38643759

RESUMO

INTRODUCTION: No evidence-based protocols exist for fetal cardiac monitoring during fetoscopic myelomeningocele (fMMC) repair and intraprocedural spectral Doppler data are limited. We determined the feasibility of continuous fetal echocardiography during fMMC repair and correlated Doppler changes with qualitative fetal cardiac function during each phase of fMMC repair. METHODS: Patients undergoing fMMC repair had continuous fetal echocardiography interpreted in real-time by pediatric cardiology. Fetal data included fetal heart rate (FHR), qualitative cardiac function, mitral and tricuspid valve inflow waveforms, and umbilical artery (UA), umbilical vein (UV), ductus arteriosus (DA), and ductus venosus (DV) Dopplers. RESULTS: UA abnormalities were noted in 14/25 patients, UV abnormalities were observed in 2 patients, and DV and DA abnormalities were each noted in 4 patients. Qualitative cardiac function was normal for all patients with the exception of one with isolated left ventricular dysfunction during myofascial flap creation, concurrent with an abnormal UA flow pattern. All abnormalities resolved by the first postoperative day. CONCLUSIONS: Continuous fetal echocardiography was feasible during all fMMC repairs. Spectral Doppler changes in the UA were common during fMMC procedures but qualitative cardiac dysfunction was rare. Abnormalities in the UV, DV, and DA Dopplers, FHR, and cardiac function were less common findings.


Assuntos
Fetoscopia , Meningomielocele , Humanos , Meningomielocele/cirurgia , Meningomielocele/diagnóstico por imagem , Fetoscopia/métodos , Feminino , Gravidez , Ultrassonografia Pré-Natal/métodos , Monitorização Fetal/métodos , Coração Fetal/diagnóstico por imagem , Coração Fetal/cirurgia , Coração Fetal/fisiopatologia , Ecocardiografia Doppler/métodos , Adulto , Estudos de Viabilidade , Artérias Umbilicais/diagnóstico por imagem
12.
Heart Rhythm ; 21(8): 1280-1288, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38403238

RESUMO

BACKGROUND: Frequent premature ventricular contractions (PVCs) and nonsustained ventricular tachycardia (NSVT) have been associated with cardiovascular disease and mortality. Their prevalence, especially in ambulatory populations, is understudied and limited by few female participants and the use of short-duration (24- to 48-hour) monitoring. OBJECTIVE: The objective of this study was to report the prevalence of frequent PVCs and NSVT in a community-based population of women likely to undergo electrocardiogram (ECG) screening by sequential patch monitoring. METHODS: Participants from the Women's Health Initiative Strong and Healthy (WHISH) trial with no history of atrial fibrillation (AF) but 5-year predicted risk of incident AF ≥5% by CHARGE-AF score were randomly selected to undergo screening with 7-day ECG patch monitors at baseline, 6 months, and 12 months. Recordings were reviewed for PVCs and NSVT (>5 beats); data were analyzed with multivariate regression models. RESULTS: There were 1067 participants who underwent ECG screening at baseline, 866 at 6 months, and 777 at 12 months. Frequent PVCs were found on at least 1 patch from 4.3% of participants, and 1 or more episodes of NSVT were found in 12 (1.1%) women. PVC frequency directly correlated with CHARGE-AF score and NSVT on any patch. Detection of frequent PVCs increased with sequential monitoring. CONCLUSION: In postmenopausal women at high risk for AF, frequent PVCs were relatively common (4.3%) and correlated with higher CHARGE-AF score. As strategies for AF screening continue to evolve, particularly in those individuals at high risk of AF, the prevalence of incidental ventricular arrhythmias is an important benchmark to guide clinical decision-making.


Assuntos
Fibrilação Atrial , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Saúde da Mulher , Humanos , Feminino , Complexos Ventriculares Prematuros/epidemiologia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Prevalência , Idoso , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Estados Unidos/epidemiologia , Eletrocardiografia Ambulatorial/métodos , Pessoa de Meia-Idade , Eletrocardiografia , Fatores de Risco , Programas de Rastreamento/métodos
13.
Cureus ; 16(2): e53914, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38343706

RESUMO

Cardiovascular complications are a major cause of morbidity and mortality after surgery, necessitating adequate and thorough preoperative risk stratification and screening. Several technological advances in cardiac remote monitoring have improved the assessment and diagnosis of cardiovascular disease in patients before and after surgery. These devices perform measurements of physiological function, including vital signs, and more advanced functions, such as electrocardiograms and heart sound recordings. Some of the currently available devices include Fitbit® (Google LLC, Mountain View, CA, USA), BodyGuardian® (Preventive Inc., Rochester, MN, USA), ZephyrTM Performance Systems (Zephyr Inc., Annapolis, MD, USA), Sensium® (The Surgical Company, Amersfoort, UT, The Netherlands), KardiaMobile® (AliveCor, Mountain View, CA, USA), Coala® Heart Monitor (Coala Life Inc., Uppsala, Sweden), Smartex® Wearable Wellness System (Smartex, Porto, LX, Portugal), Eko® CORE and DUO (Eko Health, Emeryville, CA, USA), and TytoCareTM (TytoCare Ltd., New York, USA). Early studies have applied these devices to asymptomatic individuals and those with known cardiovascular disease with good sensitivity and specificity for electrophysiologic diagnosis. These devices carry several technical and other limitations, somewhat restricting the generalization of their use to all patients. However, information gathered from these devices can further guide anesthetic technique, operative timing, and postoperative follow-up, among other variables. As telehealth becomes more prevalent and comprehensive, it is paramount for the perioperative physician to be familiar with the available cardiac remote monitoring technologies.

14.
Pregnancy Hypertens ; 36: 101112, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38401325

RESUMO

OBJECTIVES: To determine the utility of using total peripheral systemic vascular resistance assessed using non-invasive cardiac monitor for individualizing the duration of postpartum magnesium sulfate in individuals with preeclampsia with severe features. STUDY DESIGN: Single center pilot randomized controlled trial in which singleton pregnant individuals with preeclampsia with severe features were randomized to 24 h of postpartum magnesium sulfate per standard of care (control group) or individualized duration of postpartum magnesium sulfate based on reduction in post-delivery systemic vascular resistance (intervention group). Systemic vascular resistance was assessed with non-invasive cardiac monitoring using the Cheetah® system. A 30 % reduction (maintained for 1 h) from baseline post-delivery systemic vascular resistance was used as a cutoff for discontinuation of postpartum magnesium sulfate. Our primary outcome was duration of postpartum magnesium sulfate use in hours. Secondary outcomes included a composite of maternal morbidities associated with preeclampsia. RESULTS: Of 53 individuals enrolled, we excluded 6 from this analysis due to insufficient data to assess primary outcome. Baseline characteristics of the control (n = 26) and intervention (n = 21) groups were similar. Six (28.6 %) individuals in intervention group met the systemic vascular resistance criteria and had their postpartum magnesium sulfate discontinued before 24 h. The duration of postpartum magnesium sulfate infusion was shorter in the intervention group (21.6 ± 4.7 h; range: 7-24 h) compared with control group (24 h, p = 0.02). There was no difference in secondary outcomes between the two groups. There was no difference in adverse outcomes in individuals that had magnesium discontinued earlier than 24 h. CONCLUSION: Non-invasive monitoring of systemic vascular resistance can be a valuable tool to individualize the duration of postpartum magnesium sulfate for preeclampsia with severe features. These findings should be conformed in a larger trial.


Assuntos
Sulfato de Magnésio , Período Pós-Parto , Pré-Eclâmpsia , Resistência Vascular , Humanos , Feminino , Sulfato de Magnésio/administração & dosagem , Pré-Eclâmpsia/tratamento farmacológico , Gravidez , Adulto , Resistência Vascular/efeitos dos fármacos , Projetos Piloto , Monitorização Fisiológica/métodos
15.
ACS Sens ; 9(1): 126-138, 2024 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-38170944

RESUMO

Cardiac monitoring after heart surgeries is crucial for health maintenance and detecting postoperative complications early. However, current methods like rigid implants have limitations, as they require performing second complex surgeries for removal, increasing infection and inflammation risks, thus prompting research for improved sensing monitoring technologies. Herein, we introduce a nanosensor platform that is biodegradable, biocompatible, and integrated with multifunctions, suitable for use as implants for cardiac monitoring. The device has two electrochemical biosensors for sensing lactic acid and pH as well as a pressure sensor and a chemiresistor array for detecting volatile organic compounds. Its biocompatibility with myocytes has been tested in vitro, and its biodegradability and sensing function have been proven with ex vivo experiments using a three-dimensional (3D)-printed heart model and 3D-printed cardiac tissue patches. Moreover, an artificial intelligence-based predictive model was designed to fuse sensor data for more precise health assessment, making it a suitable candidate for clinical use. This sensing platform promises impactful applications in the realm of cardiac patient care, laying the foundation for advanced life-saving developments.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Humanos , Inteligência Artificial , Próteses e Implantes , Monitorização Fisiológica
17.
Artif Intell Med ; 144: 102646, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37783546

RESUMO

Perioperative monitoring of cardiac function is beneficial for early detection of cardiovascular complications. The standard of care for cardiac monitoring performed by trained cardiologists and anesthesiologists involves a manual and qualitative evaluation of ultrasound imaging, which is a time-demanding and resource-intensive process with intraobserver- and interobserver variability. In practice, such measures can only be performed a limited number of times during the intervention. To overcome these difficulties, this study presents a robust method for automatic and quantitative monitoring of cardiac function based on 3D transesophageal echocardiography (TEE) B-mode ultrasound recordings of the left ventricle (LV). Such an assessment obtains consistent measurements and can produce a near real-time evaluation of ultrasound imagery. Hence, the presented method is time-saving and results in increased accessibility. The mitral annular plane systolic excursion (MAPSE), characterizing global LV function, is estimated by landmark detection and cardiac view classification of two-dimensional images extracted along the long-axis of the ultrasound volume. MAPSE estimation directly from 3D TEE recordings is beneficial since it removes the need for manual acquisition of cardiac views, hence decreasing the need for interference by physicians. Two convolutional neural networks (CNNs) were trained and tested on acquired ultrasound data of 107 patients, and MAPSE estimates were compared to clinically obtained references in a blinded study including 31 patients. The proposed method for automatic MAPSE estimation had low bias and low variability in comparison to clinical reference measures. The method accomplished a mean difference for MAPSE estimates of (-0.16±1.06) mm. Thus, the results did not show significant systematic errors. The obtained bias and variance of the method were comparable to inter-observer variability of clinically obtained MAPSE measures on 2D TTE echocardiography. The novel pipeline proposed in this study has the potential to enhance cardiac monitoring in perioperative- and intensive care settings.


Assuntos
Inteligência Artificial , Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Ultrassonografia , Ecocardiografia/métodos , Função Ventricular Esquerda
18.
Biosens Bioelectron ; 241: 115693, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37757511

RESUMO

We present a wearable, flexible, wireless and smartphone-enabled epidermal electronic system (EES) for the continuous monitoring of a prognostic parameter for hypertension. The thin and lightweight EES can be tightly attached to the chest of a patient and synchronously monitor first lead electrocardiograms (ECG) and seismocardiograms (SCG). To demonstrate the concept, we developed the EES using state-of-the-art cleanroom technologies. Two types of sensors were integrated: A pair of metal electrodes to contact the skin and to record ECG and a vibration sensor based on a thin piezoelectric polymer to record SCG from the same location of the chest, simultaneously. The complete EES was powered by the near field communication functionality of the smartphone. We developed a machine-learning algorithm and trained it on public ECG data and recorded SCG signals to extract characteristic features of the recordings. Binary classifiers were used to automatically annotate peaks. After training, the algorithm was transferred to the smartphone to continuously analyze the timing between particular ECG and SCG peaks and to extract the Weissler's index as a prognostic parameter for hypertension. Tests with data of healthy control persons and clinical experiments with patients diagnosed with cardio-pulmonary hypertension showed a promising prognostic performance. The presented EES technology could be utilized for pre-screening of cardio-pulmonary hypertension, which is a strong burden in our today's healthcare system.


Assuntos
Técnicas Biossensoriais , Hipertensão Pulmonar , Humanos , Smartphone , Prognóstico , Eletrocardiografia , Eletrônica , Inteligência Artificial
20.
Clin Res Cardiol ; 112(12): 1835-1847, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37526697

RESUMO

BACKGROUND: Even though electrical injuries are common in the emergency room, guidelines, consensus, and general recommendations for the management of these patients do not exist in Europe. Documented cases of delayed arrhythmias are rare and their connection with electrical injury has not been fully confirmed. We also use cardio-specific markers for the risk stratification of myocardial injury, but there is no significant study referring to their utility in this clinical situation. These reasons led us to retrospectively analyze all cases of electrical injuries over 23 years to determine the prevalence of cardiac arrhythmias (mainly malignant arrhythmias and delayed arrhythmias). METHODS: We retrospectively searched all patients admitted to the University Hospital in Pilsen, CZ, with a diagnosis of electric injury (ICD diagnostic code T754) from 1997 to 2020. The hospital´s information system was used to research the injury; data were drawn from patient medical records. RESULTS: We identified 333 cases of electrical injury in our hospital. Men accounted for about two-thirds, and women one-third. Children accounted for about one-third of cases. Most were low-voltage injuries (< 1000 V, 91.6%). All participants had an initial ECG, and 77.5% of patients had continuous ECG monitoring, usually lasting 24 h. Cardiac arrhythmias were noticed in 39 patients (11.7%). The most frequent arrhythmias were: ventricular fibrillation, sinus tachycardia, bradycardia and arrhythmia, atrial fibrillation, and supraventricular tachycardia. The ECG showed cardiac conduction abnormalities in 28 patients (8.1%), and ten patients (3%) had supraventricular or ventricular extrasystoles. In ten cases (3%), we found changes in ST segments and T waves on the initial ECG. Thirty-one patients (9.3%) suffered a loss of consciousness and 50 patients (15.02%) reported paresthesia. The most frequent ion disbalances were hypokalemia (18%) and hypocalcemia (3.3%). Patients with an ion disbalance had significantly more arrhythmias and newly diagnosed cardiac conduction abnormalities. Troponin levels (cTnI or hs-cTnT) were measured in 258 cases (77.48%) and found to be elevated above the 99th percentile in 19 cases (5.7%). Almost one-third of patients had burns of various degrees of seriousness, and 41 patients (12.3%) had concomitant traumatic injuries. Eleven patients underwent pre-hospital resuscitation, three died in the hospital, and another died as result of intracranial hemorrhage. CONCLUSION: All malignant arrhythmias occurred immediately after the electrical injury, delayed life-threatening arrhythmias were not observed, and no predictive factors of malignant arrhythmias were found. While elevations of cardiac troponins were observed sporadically, they did not appear helpful for risk stratification. In patients with arrhythmias, ion disbalance may be more critical. We concluded that asymptomatic, uninjured adult and pediatric patients with normal initial ECG findings do not need continuous ECG monitoring and may be discharged home. Recommendations for high-risk patients and patients with mild ECG abnormalities at admission are less obvious.


Assuntos
Fibrilação Atrial , Traumatismos por Eletricidade , Adulto , Masculino , Humanos , Feminino , Criança , Estudos Retrospectivos , Fibrilação Atrial/complicações , Eletrocardiografia , Taquicardia Sinusal , Traumatismos por Eletricidade/complicações , Traumatismos por Eletricidade/diagnóstico , Traumatismos por Eletricidade/epidemiologia , Acidentes , Doença do Sistema de Condução Cardíaco/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA