RESUMO
PURPOSE: Cardiac magnetic resonance is the gold standard for evaluating left-ventricular ejection fraction (LVEF). Standard protocols, however, can be inefficient, facing challenges due to significant operator and patient involvement. Although the free-running framework (FRF) addresses these challenges, the potential of the extensive data it collects remains underutilized. Therefore, we propose to leverage the large amount of data collected by incorporating interbin cardiac motion compensation into FRF (FRF-MC) to improve both image quality and LVEF measurement accuracy, while reducing the sensitivity to user-defined regularization parameters. METHODS: FRF-MC consists of several steps: data acquisition, self-gating signal extraction, deformation field estimations, and motion-resolved reconstruction with interbin cardiac motion compensation. FRF-MC was compared with the original 5D-FRF method using LVEF and several image-quality metrics. The cardiac regularization weight ( λ c $$ {\lambda}_c $$ ) was optimized for both methods by maximizing image quality without compromising LVEF measurement accuracy. Evaluations were performed in numerical simulations and in 9 healthy participants. In vivo images were assessed by blinded expert reviewers and compared with reference standard 2D-cine images. RESULTS: Both in silico and in vivo results revealed that FRF-MC outperformed FRF in terms of image quality and LVEF accuracy. FRF-MC reduced temporal blurring, preserving detailed anatomy even at higher cardiac regularization weights, and led to more accurate LVEF measurements. Optimized λ c $$ {\lambda}_c $$ produced accurate LVEF for both methods compared with the 2D-cine reference (FRF-MC: 0.59% [-7.2%, 6.0%], p = 0.47; FRF: 0.86% [-8.5%, 6.7%], p = 0.36), but FRF-MC resulted in superior image quality (FRF-MC: 2.89 ± 0.58, FRF: 2.11 ± 0.47; p < 10-3). CONCLUSION: Incorporating interbin cardiac motion compensation significantly improved image quality, supported higher cardiac regularization weights without compromising LVEF measurement accuracy, and reduced sensitivity to user-defined regularization parameters.
RESUMO
In order to improve the energy efficiency of wearable devices, it is necessary to compress and reconstruct the collected electrocardiogram data. The compressed data may be mixed with noise during the transmission process. The denoising-based approximate message passing (AMP) algorithm performs well in reconstructing noisy signals, so the denoising-based AMP algorithm is introduced into electrocardiogram signal reconstruction. The weighted nuclear norm minimization algorithm (WNNM) uses the low-rank characteristics of similar signal blocks for denoising, and averages the signal blocks after low-rank decomposition to obtain the final denoised signal. However, under the influence of noise, there may be errors in searching for similar blocks, resulting in dissimilar signal blocks being grouped together, affecting the denoising effect. Based on this, this paper improves the WNNM algorithm and proposes to use weighted averaging instead of direct averaging for the signal blocks after low-rank decomposition in the denoising process, and validating its effectiveness on electrocardiogram signals. Experimental results demonstrate that the IWNNM-AMP algorithm achieves the best reconstruction performance under different compression ratios and noise conditions, obtaining the lowest PRD and RMSE values. Compared with the WNNM-AMP algorithm, the PRD value is reduced by 0.17â¼4.56, the P-SNR value is improved by 0.12â¼2.70.
RESUMO
Magnetic resonance imaging (MRI) is widely used in clinical diagnosis as a safe, non-invasive, high-resolution medical imaging technology, but long scanning time has been a major challenge for this technology. The undersampling reconstruction method has become an important technical means to accelerate MRI by reducing the data sampling rate while maintaining high-quality imaging. However, traditional undersampling reconstruction techniques such as compressed sensing mainly rely on relatively single sparse or low-rank prior information to reconstruct the image, which has limitations in capturing the comprehensive features of images, resulting in the insufficient performance of the reconstructed image in terms of details and key information. In this paper, we propose a deep plug-and-play multiple complementary priors MRI reconstruction model, which combines traditional low-rank matrix recovery model methods and deep learning methods, and integrates global, local and nonlocal priors to improve reconstruction quality. Specifically, we capture the global features of the image through the matrix nuclear norm, and use the deep convolutional neural network denoiser Swin-Conv-UNet (SCUNet) and block-matching and 3-D filtering (BM3D) algorithm to preserve the local details and structural texture of the image, respectively. In addition, we utilize an efficient half-quadratic splitting (HQS) algorithm to solve the proposed model. The experimental results show that our proposed method has better reconstruction ability than the existing popular methods in terms of visual effects and numerical results.
RESUMO
BACKGROUND: Conventional MR acceleration techniques, such as compressed sensing, parallel imaging, and half Fourier often face limitations, including noise amplification, reduced signal-to-noise ratio (SNR) and increased susceptibility to artifacts, which can compromise image quality, especially in high-speed acquisitions. Artificial intelligence (AI)-assisted compressed sensing (ACS) has emerged as a novel approach that combines the conventional techniques with advanced AI algorithms. The objective of this study was to examine the imaging quality of the ACS approach by qualitative and quantitative analysis for brain, spine, kidney, liver, and knee MR imaging, as well as compare the performance of this method with conventional (non-ACS) MR imaging. METHODS: This study included 50 subjects. Three radiologists independently assessed the quality of MR images based on artefacts, image sharpness, overall image quality and diagnostic efficacy. SNR, contrast-to-noise ratio (CNR), edge content (EC), enhancement measure (EME), scanning time were used for quantitative evaluation. The Cohen's kappa correlation coefficient (k) was employed to measure radiologists' inter-observer agreement, and the Mann Whitney U-test used for comparison between non-ACS and ACS. RESULTS: The qualitative analysis of three radiologists demonstrated that ACS images showed superior clinical information than non-ACS images with a mean k of ~ 0.70. The images acquired with ACS approach showed statistically higher values (p < 0.05) for SNR, CNR, EC, and EME compared to the non-ACS images. Furthermore, the study's findings indicated that ACS-enabled images reduced scan time by more than 50% while maintaining high imaging quality. CONCLUSION: Integrating ACS technology into routine clinical settings has the potential to speed up image acquisition, improve image quality, and enhance diagnostic procedures and patient throughput.
Assuntos
Inteligência Artificial , Imageamento por Ressonância Magnética , Razão Sinal-Ruído , Humanos , Imageamento por Ressonância Magnética/métodos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Encéfalo/diagnóstico por imagem , Artefatos , Idoso , Compressão de Dados/métodos , Fígado/diagnóstico por imagem , Algoritmos , Rim/diagnóstico por imagem , Adulto Jovem , Coluna Vertebral/diagnóstico por imagem , Variações Dependentes do Observador , Joelho/diagnóstico por imagemRESUMO
Background: Shortening the acquisition time of brain three-dimensional T2 fluid-attenuated inversion recovery (3D T2 FLAIR) by using acceleration techniques has the potential to reduce motion artifacts in images and facilitate clinical application. This study aimed to assess the image quality of brain 3D T2 FLAIR accelerated by artificial intelligence-assisted compressed sensing (ACS) in comparison to 3D T2 FLAIR accelerated by parallel imaging (PI). Methods: In this prospective cohort study, 102 consecutive participants, including both healthy individuals and those with suspected brain diseases, were recruited and underwent both ACS- and PI-3D T2 FLAIR scans with a 3.0-Tesla magnetic resonance imaging system from February 2023 to October 2023 in Beijing Tiantan Hospital, Capital Medical University. Quantitative assessment involved white matter (WM) and gray matter (GM) signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), whole-image sharpness, and tumor volume. Qualitative assessment included the scoring of overall image quality, GM-WM border sharpness, and diagnostic confidence in lesion detection. Results: ACS-3D T2 FLAIR exhibited a shorter acquisition time compared to PI-3D T2 FLAIR (105 vs. 320 seconds). ACS-3D T2 FLAIR, compared to PI-3D T2 FLAIR, demonstrated a significantly higher mean SNRWM (25.922±6.811 vs. 22.544±5.853; P<0.001), SNRGM (18.324±7.137 vs. 17.102±6.659; P=0.049), CNRWM/GM (4.613±1.547 vs. 4.160±1.552; P<0.001), and sharpness (0.413±0.049 vs. 0.396±0.034; P<0.001), while no significant differences were found for the overall image quality ratings (P=0.063) or GM-WM border sharpness ratings (P=0.125). A good agreement on tumor volume was achieved between ACS-3D T2 FLAIR and PI-3D T2 FLAIR images (intraclass correlation coefficient =0.999; 0.998-1.000; P<0.001). Images acquired with ACS demonstrated nearly equivalent diagnostic confidence to those obtained with PI (P>0.05). Conclusions: The ACS technique offers a substantial reduction in scanning time for brain 3D T2 FLAIR compared to PI while maintaining good image quality and equivalent diagnostic confidence.
RESUMO
In Magnetic Resonance Imaging (MRI), the sequential acquisition of raw complex-valued image data in Fourier space, also known as k-space, results in extended examination times. To speed up the MRI scans, k-space data are usually undersampled and processed using numerical techniques such as compressed sensing (CS). While the majority of CS-MRI algorithms primarily focus on magnitude images due to their significant diagnostic value, the phase components of complex-valued MRI images also hold substantial importance for clinical diagnosis, including neurodegenerative diseases. In this work, complex-valued MRI reconstruction is studied with a focus on the simultaneous reconstruction of both magnitude and phase images. The proposed algorithm is based on the nonsubsampled contourlet transform (NSCT) technique, which offers shift invariance in images. Instead of directly transforming the complex-valued image into the NSCT domain, we introduce a wavelet transform within the NSCT domain, reducing the size of the sparsity of coefficients. This two-level hierarchical constraint (HC) enforces sparse representation of complex-valued images for CS-MRI implementation. The proposed HC is seamlessly integrated into a proximal algorithm simultaneously. Additionally, to effectively minimize the artifacts caused by sub-sampling, thresholds related to different sub-bands in the HC are applied through an alternating optimization process. Experimental results show that the novel method outperforms existing CS-MRI techniques in phase-regularized complex-valued image reconstructions.
RESUMO
Model-based methods are widely used for reconstruction in compressed sensing (CS) magnetic resonance imaging (MRI), using regularizers to describe the images of interest. The reconstruction process is equivalent to solving a composite optimization problem. Accelerated proximal methods (APMs) are very popular approaches for such problems. This paper proposes a complex quasi-Newton proximal method (CQNPM) for the wavelet and total variation based CS MRI reconstruction. Compared with APMs, CQNPM requires fewer iterations to converge but needs to compute a more challenging proximal mapping called weighted proximal mapping (WPM). To make CQNPM more practical, we propose efficient methods to solve the related WPM. Numerical experiments on reconstructing non-Cartesian MRI data demonstrate the effectiveness and efficiency of CQNPM.
RESUMO
Through extensive literature review, it has been found that sparse Bayesian learning (SBL) is mainly applied to traditional scalar hydrophones and is rarely applied to vector hydrophones. This article proposes a direction of arrival (DOA) estimation method for vector hydrophones based on SBL (Vector-SBL). Firstly, vector hydrophones capture both sound pressure and particle velocity, enabling the acquisition of multidimensional sound field information. Secondly, SBL accurately reconstructs the received vector signal, addressing challenges like low signal-to-noise ratio (SNR), limited snapshots, and coherent sources. Finally, precise DOA estimation is achieved for multiple sources without prior knowledge of their number. Simulation experiments have shown that compared with the OMP, MUSIC, and CBF algorithms, the proposed method exhibits higher DOA estimation accuracy under conditions of low SNR, small snapshots, multiple sources, and coherent sources. Furthermore, it demonstrates superior resolution when dealing with closely spaced signal sources.
RESUMO
The reconstruction of MR images has always been a challenging inverse problem in medical imaging. Acceleration of MR scanning is of great importance for clinical research and cutting-edge applications. One of the primary efforts to achieve this is using compressed sensing (CS) theory. The CS aims to reconstruct MR images using a small number of sampled data in k-space. The CS-MRI techniques face challenges, including the potential loss of fine structure and increased computational complexity. We introduce a novel framework based on a regularized sparse recovery problem and a sharpening step to improve the CS-MRI approaches regarding fine structure loss under high acceleration factors. This problem is solved via the Half Quadratic Splitting (HQS) approach. The inverse problem for reconstructing MR images is converted into two distinct sub-problems, each of which can be solved separately. One key feature of the proposed approach is the replacement of one sub-problem with a denoiser. This regularization assists the optimization of the Smoothed [Formula: see text] (SL0) norm in escaping local minimums and enhances its precision. The proposed method consists of smoothing, feature modification, and Smoothed [Formula: see text] cost function optimization. The proposed approach improves the SL0 algorithm for MRI reconstruction without complicating it. The convergence of the proposed approach is illustrated analytically. The experimental results show an acceptable performance of the proposed method compared to the network-based approaches.
RESUMO
PURPOSE: Three-dimensional hyperpolarized 129Xe gas exchange imaging suffers from low SNR and long breath-holds, which could be improved using compressed sensing (CS). The purpose of this work was to assess whether gas exchange ratio maps are quantitatively preserved in CS-accelerated dissolved-phase 129Xe imaging and to investigate the feasibility of CS-dissolved 129Xe imaging with reduced-cost natural abundance (NA) xenon. METHODS: 129Xe gas exchange imaging was performed at 1.5 T with a multi-echo spectroscopic imaging sequence. A CS reconstruction with an acceleration factor of 2 was compared retrospectively with conventional gridding reconstruction in a cohort of 16 healthy volunteers, 5 chronic obstructive pulmonary disease patients, and 23 patients who were hospitalized following COVID-19 infection. Metrics of comparison included normalized mean absolute error, mean gas exchange ratio, and red blood cell (RBC) image SNR. Dissolved 129Xe CS imaging with NA xenon was assessed in 4 healthy volunteers. RESULTS: CS reconstruction enabled acquisition time to be halved, and it reduced background noise. Median RBC SNR increased from 6 (2-18) to 11 (2-100) with CS, and there was strong agreement between CS and gridding mean ratio map values (R2 = 0.99). Image fidelity was maintained for gridding RBC SNR > 5, but below this, normalized mean absolute error increased nonlinearly with decreasing SNR. CS increased the mean SNR of NA 129Xe images 3-fold. CONCLUSION: CS reconstruction of dissolved 129Xe imaging improved image quality with decreased scan time, while preserving key gas exchange metrics. This will benefit patients with breathlessness and/or low gas transfer and shows promise for NA-dissolved 129Xe imaging.
RESUMO
Introduction: High-resolution whole-heart coronary magnetic resonance angiography (CMRA) often suffers from unreasonably long scan times, rendering imaging acceleration highly desirable. Traditional reconstruction methods used in CMRA rely on either hand-crafted priors or supervised learning models. Although the latter often yield superior reconstruction quality, they require a large amount of training data and memory resources, and may encounter generalization issues when dealing with out-of-distribution datasets. Methods: To address these challenges, we introduce an unsupervised reconstruction method that combines deep image prior (DIP) with compressed sensing (CS) to accelerate 3D CMRA. This method incorporates a slice-by-slice DIP reconstruction and 3D total variation (TV) regularization, enabling high-quality reconstruction under a significant acceleration while enforcing continuity in the slice direction. We evaluated our method by comparing it to iterative SENSE, CS-TV, CS-wavelet, and other DIP-based variants, using both retrospectively and prospectively undersampled datasets. Results: The results demonstrate the superiority of our 3D DIP-CS approach, which improved the reconstruction accuracy relative to the other approaches across both datasets. Ablation studies further reveal the benefits of combining DIP with 3D TV regularization, which leads to significant improvements of image quality over pure DIP-based methods. Evaluation of vessel sharpness and image quality scores shows that DIP-CS improves the quality of reformatted coronary arteries. Discussion: The proposed method enables scan-specific reconstruction of high-quality 3D CMRA from a five-minute acquisition, without relying on fully-sampled training data or placing a heavy burden on memory resources.
RESUMO
Magnetic Resonance Imaging (MRI) plays a pivotal role in modern clinical practice, providing detailed anatomical visualization with exceptional spatial resolution and soft tissue contrast. Dynamic MRI, aiming to capture both spatial and temporal characteristics, faces challenges related to prolonged acquisition times and susceptibility to motion artifacts. Balancing spatial and temporal resolutions becomes crucial in real-world clinical scenarios. In the realm of dynamic MRI reconstruction, while Convolutional Recurrent Neural Networks (CRNNs) struggle with long-range dependencies, CRNNs require extensive iterations, impacting efficiency. Transformers, known for their effectiveness in high-dimensional imaging, are underexplored in dynamic MRI reconstruction. Additionally, prevailing algorithms fall short of achieving superior results in demanding generative reconstructions at high acceleration rates. This research proposes a novel approach for dynamic MRI reconstruction, named CRNN-Refined Spatiotemporal Transformer Network (CST-Net). The spatiotemporal Transformer initiates reconstruction, modeling temporal and spatial correlations, followed by refinement using the CRNN. This integration mitigates inaccuracies caused by damaged frames and reduces CRNN iterations, enhancing computational efficiency without compromising reconstruction quality. Our study compares the performance of the proposed CST-Net at 6 × and 12 × undersampling rates, showcasing its superiority over existing algorithms. Particularly, in challenging 25× generative reconstructions, the CST-Net outperforms current methods. The comparison includes experiments under both radial and Cartesian undersampling patterns. In conclusion, CST-Net successfully addresses the limitations inherent in existing generative reconstruction algorithms, thereby paving the way for further exploration and optimization of Transformer-based approaches in dynamic MRI reconstruction. Code and Datasets can be available: https://github.com/XWangBin/CST-Net.
RESUMO
Medical Speed-of-sound (SoS) imaging, which can characterize medical tissue properties better by quantifying their different SoS, is an effective imaging method compared with conventional B-mode ultrasound imaging. As a commonly used diagnostic instrument, a hand-held array probe features convenient and quick inspection. However, artifacts will occur in the single-angle SoS imaging, resulting in indistinguishable tissue boundaries. In order to build a high-quality SoS image, a number of raw data are needed, which will bring difficulties to data storage and processing. Compressed sensing (CS) theory offers theoretical support to the feasibility that a sparse signal can be rebuilt with random but less sampling data. In this study, we proposed an SoS reconstruction method based on CS theory to process signals obtained from a hand-held linear array probe with a passive reflector positioned on the opposite side. The SoS reconstruction method consists of three parts. Firstly, a sparse transform basis is selected appropriately for a sparse representation of the original signal. Then, considering the mathematical principles of SoS imaging, the ray-length matrix is used as a sparse measurement matrix to observe the original signal, which represents the length of the acoustic propagation path. Finally, the orthogonal matching pursuit algorithm is introduced for image reconstruction. The experimental result of the phantom proves that SoS imaging can clearly distinguish tissues that show similar echogenicity in B-mode ultrasound imaging. The simulation and experimental results show that our proposed method holds promising potential for reconstructing precision SoS images with fewer signal samplings, transmission, and storage.
Assuntos
Algoritmos , Imagens de Fantasmas , Ultrassonografia , Ultrassonografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , HumanosRESUMO
PURPOSE: To achieve automatic hyperparameter estimation for the model-based recovery of quantitative MR maps from undersampled data, we propose a Bayesian formulation that incorporates the signal model and sparse priors among multiple image contrasts. THEORY: We introduce a novel approximate message passing framework "AMP-PE" that enables the automatic and simultaneous recovery of hyperparameters and quantitative maps. METHODS: We employed the variable-flip-angle method to acquire multi-echo measurements using gradient echo sequence. We explored undersampling schemes to incorporate complementary sampling patterns across different flip angles and echo times. We further compared AMP-PE with conventional compressed sensing approaches such as the l 1 $$ {l}_1 $$ -norm minimization, PICS and other model-based approaches such as GraSP, MOBA. RESULTS: Compared to conventional compressed sensing approaches such as the l 1 $$ {l}_1 $$ -norm minimization and PICS, AMP-PE achieved superior reconstruction performance with lower errors in T 2 ∗ $$ {\mathrm{T}}_2^{\ast } $$ mapping and comparable performance in T 1 $$ {\mathrm{T}}_1 $$ and proton density mappings. When compared to other model-based approaches including GraSP and MOBA, AMP-PE exhibited greater robustness and outperformed GraSP in reconstruction error. AMP-PE offers faster speed than MOBA. AMP-PE performed better than MOBA at higher sampling rates and worse than MOBA at a lower sampling rate. Notably, AMP-PE eliminates the need for hyperparameter tuning, which is a requisite for all the other approaches. CONCLUSION: AMP-PE offers the benefits of model-based recovery with the additional key advantage of automatic hyperparameter estimation. It works adeptly in situations where ground-truth is difficult to obtain and in clinical environments where it is desirable to automatically adapt hyperparameters to individual protocol, scanner and patient.
RESUMO
Compressed Sensing (CS) is a groundbreaking paradigm in image acquisition, challenging the constraints of the Nyquist-Shannon sampling theorem. This enables high-quality image reconstruction using a minimal number of measurements. Neural Networks' potent feature induction capabilities enable advanced data-driven CS methods to achieve high-fidelity image reconstruction. However, achieving satisfactory reconstruction performance, particularly in terms of perceptual quality, remains challenging at extremely low sampling rates. To tackle this challenge, we introduce a novel two-stage image CS framework based on latent diffusion, named LD-CSNet. In the first stage, we utilize an autoencoder pre-trained on a large dataset to represent natural images as low-dimensional latent vectors, establishing prior knowledge distinct from sparsity and effectively reducing the dimensionality of the solution space. In the second stage, we employ a conditional diffusion model for maximum likelihood estimates in the latent space. This is supported by a measurement embedding module designed to encode measurements, making them suitable for a denoising network. This guides the generation process in reconstructing low-dimensional latent vectors. Finally, the image is reconstructed using a pre-trained decoder. Experimental results across multiple public datasets demonstrate LD-CSNet's superior perceptual quality and robustness to noise. It maintains fidelity and visual quality at lower sampling rates. Research findings suggest the promising application of diffusion models in image CS. Future research can focus on developing more appropriate models for the first stage.
Assuntos
Processamento de Imagem Assistida por Computador , Redes Neurais de Computação , Humanos , Processamento de Imagem Assistida por Computador/métodos , Compressão de Dados/métodos , Algoritmos , DifusãoRESUMO
PURPOSE: To implement rosette readout trajectories with compressed sensing reconstruction for fast and motion-robust CEST and magnetization transfer contrast imaging with inherent correction of B0 inhomogeneity. METHODS: A pulse sequence was developed for fast saturation transfer imaging using a stack of rosette trajectories with a higher sampling density near the k-space center. Each rosette lobe was segmented into two halves to generate dual-echo images. B0 inhomogeneities were estimated using the phase difference between the images and corrected subsequently. The rosette-based imaging was evaluated in comparison to a fully sampled Cartesian trajectory and demonstrated on CEST phantoms (creatine solutions and egg white) and healthy volunteers at 3 T. RESULTS: Compared with the conventional Cartesian acquisition, compressed sensing reconstructed rosette images provided image quality with overall higher contrast-to-noise ratio and significantly faster readout time. Accurate B0 map estimation was achieved from the rosette acquisition with a negligible bias of 0.01 Hz between the rosette and dual-echo Cartesian gradient echo B0 maps, using the latter as ground truth. The water-saturation spectra (Z-spectra) and amide proton transfer weighted signals obtained from the rosette-based sequence were well preserved compared with the fully sampled data, both in the phantom and human studies. CONCLUSIONS: Fast, motion-robust, and inherent B0-corrected CEST and magnetization transfer contrast imaging using rosette trajectories could improve subject comfort and compliance, contrast-to-noise ratio, and provide inherent B0 homogeneity information. This work is expected to significantly accelerate the translation of CEST-MRI into a robust, clinically viable approach.
Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Humanos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Encéfalo/diagnóstico por imagem , Movimento (Física) , Compressão de Dados/métodos , Voluntários Saudáveis , Razão Sinal-Ruído , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/métodos , Aumento da Imagem/métodosRESUMO
OBJECTIVES: Compressed sensing allows for image reconstruction from sparsely sampled k-space data, which is particularly useful in dynamic contrast enhanced MRI (DCE-MRI). The aim of the study was to assess the diagnostic value of a volume-interpolated 3D T1-weighted spoiled gradient-echo sequence with variable density Cartesian undersampling and compressed sensing (CS) for head and neck MRI. METHODS: Seventy-one patients with clinical indications for head and neck MRI were included in this study. DCE-MRI was performed at 3 Tesla magnet using CS-VIBE (variable density undersampling, temporal resolution 3.4 s, slice thickness 1 mm). Image quality was compared to standard Cartesian VIBE. Three experienced readers independently evaluated image quality and lesion conspicuity on a 5-point Likert scale and determined the DCE-derived time intensity curve (TIC) types. RESULTS: CS-VIBE demonstrated higher image quality scores compared to standard VIBE with respect to overall image quality (4.3 ± 0.6 vs. 4.2 ± 0.7, p = 0.682), vessel contour (4.6 ± 0.4 vs. 4.4 ± 0.6, p < 0.001), muscle contour (4.4 ± 0.5 vs. 4.5 ± 0.6, p = 0.302), lesion conspicuity (4.5 ± 0.7 vs. 4.3 ± 0.9, p = 0.024) and showed improved fat saturation (4.8 ± 0.3 vs. 3.8 ± 0.4, p < 0.001) and movement artifacts were significantly reduced (4.6 ± 0.6 vs. 3.7 ± 0.7, p < 0.001). Standard VIBE outperformed CS-VIBE in the delineation of pharyngeal mucosa (4.2 ± 0.5 vs. 4.6 ± 0.6, p < 0.001). Lesion size in cases where a focal lesion was identified was similar for all readers for CS-VIBE and standard VIBE (p = 0.101). TIC curve assessment showed good interobserver agreement (k=0.717). CONCLUSION: CS-VIBE with variable density Cartesian undersampling allows for DCE-MRI of the head and neck region with diagnostic, high image quality and high temporal resolution.
Assuntos
Meios de Contraste , Neoplasias de Cabeça e Pescoço , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Pescoço/diagnóstico por imagem , Aumento da Imagem/métodos , Idoso de 80 Anos ou mais , Cabeça/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Adulto Jovem , Compressão de Dados/métodos , AlgoritmosRESUMO
Compressed ultrafast photography (CUP) can capture irreversible or difficult-to-repeat dynamic scenes at the imaging speed of more than one billion frames per second, which is obtained by compressive sensing-based image reconstruction from a compressed 2D image through the discretization of detector pixels. However, an excessively high data compression ratio in CUP severely degrades the image reconstruction quality, thereby restricting its ability to observe ultrafast dynamic scenes with complex spatial structures. To address this issue, a discrete illumination-based CUP (DI-CUP) with high fidelity is reported. In DI-CUP, the dynamic scenes are loaded into an ultrashort laser pulse train with controllable sub-pulse number and time interval, thus the data compression ratio, as well as the overlap between adjacent frames, is greatly decreased and flexibly controlled through the discretization of dynamic scenes based on laser pulse train illumination, and high-fidelity image reconstruction can be realized within the same observation time window. Furthermore, the superior performance of DI-CUP is verified by observing femtosecond laser-induced ablation dynamics and plasma channel evolution, which are hardly resolved in the spatial structures using conventional CUP. It is anticipated that DI-CUP will be widely and dependably used in the real-time observations of various ultrafast dynamics.
RESUMO
Objective: To investigate the feasibility and performance of 4D flow MRI accelerated by compressed sensing (CS) for the hemodynamic quantification of intracranial artery and venous sinus. Materials and methods: Forty healthy volunteers were prospectively recruited, and 20 volunteers underwent 4D flow MRI of cerebral artery, and the remaining volunteers underwent 4D flow MRI of venous sinus. A series of 4D flow MRI was acquired with different acceleration factors (AFs), including sensitivity encoding (SENSE, AF = 4) and CS (AF = CS4, CS6, CS8, and CS10) at a 3.0 T MRI scanner. The hemodynamic parameters, including flow rate, mean velocity, peak velocity, max axial wall shear stress (WSS), average axial WSS, max circumferential WSS, average circumferential WSS, and 3D WSS, were calculated at the internal carotid artery (ICA), transverse sinus (TS), straight sinus (SS), and superior sagittal sinus (SSS). Results: Compared to the SENSE4 scan, for the left ICA C2, mean velocity measured by CS8 and CS10 groups, and 3D WSS measured by CS6, CS8, and CS10 groups were underestimated; for the right ICA C2, mean velocity measured by CS10 group, and 3D WSS measured by CS8 and CS10 groups were underestimated; for the right ICA C4, mean velocity measured by CS10 group, and 3D WSS measured by CS8 and CS10 groups were underestimated; and for the right ICA C7, mean velocity and 3D WSS measured by CS8 and CS10 groups, and average axial WSS measured by CS8 group were also underestimated (all p < 0.05). For the left TS, max axial WSS and 3D WSS measured by CS10 group were significantly underestimated (p = 0.032 and 0.003). Similarly, for SS, mean velocity, peak velocity, average axial WSS measured by the CS8 and CS10 groups, max axial WSS measured by CS6, CS8, and CS10 groups, and 3D WSS measured by CS10 group were significantly underestimated compared to the SENSE4 scan (p = 0.000-0.021). The hemodynamic parameters measured by CS4 group had only minimal bias and great limits of agreement compared to conventional 4D flow (SENSE4) in the ICA and every venous sinus (the max/min upper limit to low limit of the 95% limits of agreement = 11.4/0.03 to 0.004/-5.7, 14.4/0.05 to -0.03/-9.0, 12.6/0.04 to -0.03/-9.4, 16.8/0.04 to 0.6/-14.1; the max/min bias = 5.0/-1.2, 3.5/-1.4, 4.5/-1.1, 6.6/-4.0 for CS4, CS6, CS8, and CS10, respectively). Conclusion: CS4 strikes a good balance in 4D flow between flow quantifications and scan time, which could be recommended for routine clinical use.
RESUMO
Compressed sensing (CS) is a novel technique for MRI acceleration. The purpose of this paper was to assess the effects of CS on the radiomic features extracted from amide proton transfer-weighted (APTw) images. Brain tumor MRI data of 40 scans were studied. Standard images using sensitivity encoding (SENSE) with an acceleration factor (AF) of 2 were used as the gold standard, and APTw images using SENSE with CS (CS-SENSE) with an AF of 4 were assessed. Regions of interest (ROIs), including normal tissue, edema, liquefactive necrosis, and tumor, were manually drawn, and the effects of CS-SENSE on radiomics were assessed for each ROI category. An intraclass correlation coefficient (ICC) was first calculated for each feature extracted from APTw images with SENSE and CS-SENSE for all ROIs. Different filters were applied to the original images, and the effects of these filters on the ICCs were further compared between APTw images with SENSE and CS-SENSE. Feature deviations were also provided for a more comprehensive evaluation of the effects of CS-SENSE on radiomic features. The ROI-based comparison showed that most radiomic features extracted from CS-SENSE-APTw images and SENSE-APTw images had moderate or greater reliabilities (ICC ≥ 0.5) for all four ROIs and all eight image sets with different filters. Tumor showed significantly higher ICCs than normal tissue, edema, and liquefactive necrosis. Compared to the original images, filters (such as Exponential or Square) may improve the reliability of radiomic features extracted from CS-SENSE-APTw and SENSE-APTw images.