Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
J Neural Eng ; 21(4)2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39029477

RESUMO

Objective. Monitoring the depth of anaesthesia (DOA) during surgery is of critical importance. However, during surgery electroencephalography (EEG) is usually subject to various disturbances that affect the accuracy of DOA. Therefore, accurately estimating noise in EEG and reliably assessing DOA remains an important challenge. In this paper, we proposed a signal quality index (SQI) network (SQINet) for assessing the EEG signal quality and a DOA network (DOANet) for analyzing EEG signals to precisely estimate DOA. The two networks are termed SQI-DOANet.Approach. The SQINet contained a shallow convolutional neural network to quickly determine the quality of the EEG signal. The DOANet comprised a feature extraction module for extracting features, a dual attention module for fusing multi-channel and multi-scale information, and a gated multilayer perceptron module for extracting temporal information. The performance of the SQI-DOANet model was validated by training and testing the model on the large VitalDB database, with the bispectral index (BIS) as the reference standard.Main results. The proposed DOANet yielded a Pearson correlation coefficient with the BIS score of 0.88 in the five-fold cross-validation, with a mean absolute error (MAE) of 4.81. The mean Pearson correlation coefficient of SQI-DOANet with the BIS score in the five-fold cross-validation was 0.82, with an MAE of 5.66.Significance. The SQI-DOANet model outperformed three compared methods. The proposed SQI-DOANet may be used as a new deep learning method for DOA estimation. The code of the SQI-DOANet will be made available publicly athttps://github.com/YuRui8879/SQI-DOANet.


Assuntos
Anestesia , Eletroencefalografia , Redes Neurais de Computação , Eletroencefalografia/métodos , Eletroencefalografia/normas , Humanos , Anestesia/métodos , Aprendizado Profundo , Processamento de Sinais Assistido por Computador
2.
Indian J Anaesth ; 68(4): 334-339, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38586256

RESUMO

Background and Aims: Laryngoscopy and tracheal intubation require an adequate depth of anaesthesia. The study's primary objective was to compare the time needed to achieve the bispectral index (BIS)-guided adequate depth of anaesthesia for endotracheal intubation using fentanyl and dexmedetomidine. Methods: After institutional ethics committee clearance and written informed consent, this randomised study was conducted on 140 patients of either gender between 18 and 60 years who were scheduled for elective surgeries under general anaesthesia. Patients were randomised to intravenous dexmedetomidine 1 µg/kg (Group D) or fentanyl 2 µg/kg (Group F). The drugs were given as an intravenous infusion over 10 min before induction of anaesthesia. The primary outcome was the time required to achieve BIS 50. Normally distributed variables were compared using Student's t-test, and non-normally distributed variables were compared using the Mann-Whitney U test. Qualitative data were analysed using Chi-square/Fisher's exact test. A P value <0.05 was considered significant. Results: The time to achieve BIS 50 was lesser in Group F, 1546 (27) as compared to Group D, 1558 (11) s [mean difference (95% confidence interval (CI) 12[5.11, 18.89]), P < 0.001]. Haemodynamic parameters were comparable at all time points between both the groups, except heart rate, which was significantly lower. Propofol consumption was significantly less in group D than in group F [125.9 (25.36) versus 157.3 (42.80) mg, respectively, mean difference (95% CI) 31.4 (-44.16 to -20.63) P < 0.001)]. Conclusion: Dexmedetomidine achieves BIS 50 faster and has a propofol-sparing effect as compared to fentanyl.

3.
Br J Anaesth ; 132(2): 285-299, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38114354

RESUMO

The central and peripheral nervous systems are the primary target organs during anaesthesia. At the time of the inception of the British Journal of Anaesthesia, monitoring of the central nervous system comprised clinical observation, which provided only limited information. During the 100 yr since then, and particularly in the past few decades, significant progress has been made, providing anaesthetists with tools to obtain real-time assessments of cerebral neurophysiology during surgical procedures. In this narrative review article, we discuss the rationale and uses of electroencephalography, evoked potentials, near-infrared spectroscopy, and transcranial Doppler ultrasonography for intraoperative monitoring of the central and peripheral nervous systems.


Assuntos
Anestesia , Monitorização Intraoperatória , Humanos , Monitorização Intraoperatória/métodos , Potenciais Evocados , Eletroencefalografia , Sistema Nervoso Periférico , Ultrassonografia Doppler Transcraniana
4.
Animals (Basel) ; 13(22)2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-38003196

RESUMO

A wide variety of substances have been used to anaesthetise invertebrates, but many are not anaesthetics and merely incapacitate animals rather than preventing pain. In essence, the role of an ideal general anaesthetic is to act as a muscle relaxant, an analgesic, an anaesthetic, and an amnesic. To achieve all these properties with a single substance is difficult, and various adjuvants usually need to be administered, resulting in a cocktail of drugs. In a clinical setting, the vast majority of patients are unaware of surgery being carried out and have no memory of it, so they can claim to have felt no pain, but this is much more difficult to demonstrate in invertebrates. Here, we show that 1% MgCl2, a muscle relaxant, is a useful adjuvant for the clinical anaesthetic isoflurane on Octopus vulgaris when applied alone in seawater for 10 min before the clinical anaesthetic. After this, full anaesthesia can be achieved in 5 min using 1% isoflurane insufflated into the saline still containing MgCl2. Full recovery takes place rapidly in about 10 to 15 min. The depth of anaesthesia was monitored using changes in respiratory rate, chromatophore pattern, and withdrawal movements of the arms and siphon. This methodology reduces stress on the animal and minimises the quantity of anaesthetic used.

5.
Br J Anaesth ; 131(5): 882-892, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37879777

RESUMO

BACKGROUND: The GE Entropy™ monitor analyses the frontal electroencephalogram (EEG) and generates two indices intended to represent the degree of anaesthetic drug effect on the brain. It is frequently used in the context of neuromuscular block. We have shown that a similar device, the Bispectral Index monitor (BIS), does not generate correct values in awake volunteers when neuromuscular blocking drugs are administered. METHODS: We replayed the EEGs recorded during awake paralysis from the original study to an Entropy monitor via a calibrated electronic playback system. Each EEG was replayed 30 times to evaluate the consistency of the Entropy output. RESULTS: Both State Entropy and Response Entropy decreased during periods of neuromuscular block to values consistent with anaesthesia, despite there being no change in conscious state (State Entropy <60 in eight of nine rocuronium trials and nine of 10 suxamethonium trials). Entropy values did not return to pre-test levels until after the return of movement. Entropy did not generate exactly the same results when the same EEG was replayed multiple times, which is primarily because of a cyclical state within the Entropy system itself. CONCLUSIONS: The GE Entropy™ monitor requires muscle activity to generate correct values in an awake subject. It could therefore be unreliable at detecting awareness in patients who have been given neuromuscular blocking drugs. In addition, Entropy does not generate the same result each time it is presented with the same EEG.


Assuntos
Anestesia , Bloqueio Neuromuscular , Humanos , Vigília , Monitorização Intraoperatória/métodos , Voluntários
6.
Turk J Anaesthesiol Reanim ; 51(5): 414-419, 2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37876168

RESUMO

Objective: Infertility anxiety may have a harmful effect on embryo quality and fertilization during in vitro fertilization (IVF). Monitoring brain function gives real-time information about the depth of anaesthesia of a patient. This study examined the effect of preoperative anxiety on the depth of anaesthesia and IVF success. Methods: One hundred thirty-one patients who had undergone oocyte retrieval were divided into two groups according to the Beck Anxiety Inventory (BAI): the low-anxious Group L (n = 71) and high-anxious Group H (n = 60). Hemodynamic stability, intraoperative total propofol and fentanyl consumption, good quality embryo (GQE) rate, and fertilization rate were recorded. Results: Fertilization and GQE rates were not significant between groups L and H. Total propofol consumption was significantly higher in group H than in group L. Heart rate (HR) preoperatively and postoperatively and systolic arterial pressure (SAP) preoperatively and diastolic arterial pressure (DAP) postoperatively were significantly increased in group H than in group L. The time for the modified Aldrete score to reach 9 (MAS 9) in group H was significantly higher than that in group L. The effect of variables that were found significantly in the univariate analysis (Propofol, HRpreop, HRpostop, SAPpreop, DAPpostop, and MAS 9) on BAI score. Conclusion: Total propofol consumption was higher in patients with high anxiety levels, but it did not have a negative effect on IVF success.

7.
Animals (Basel) ; 13(17)2023 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-37684963

RESUMO

Two young (11-week-old) pigs underwent sole propofol anaesthesia as part of an experimental study. The depth of anaesthesia was evaluated both clinically and using the electroencephalography(EEG)-based monitor Sedline; in particular, the patient state index, suppression ratio, raw EEG traces, and its spectrogram were assessed. Physiological parameters and electrocardiographic activity were continuously monitored. In one pig (Case 1), during the administration of high doses of propofol, the Sedline-generated variables suddenly indicated an increased EEG activity while this was not confirmed by observation of either the raw EEG or its spectrogram. In the second pig (Case 2), a similar event was recorded during euthanasia with systemic pentobarbital. Both events happened while the EEG activity was isoelectric except for signal interferences and synchronous in rhythm and shape with the electrocardiographic activity. The suggestion of increased brain activity based on the interpretation of the Sedline variables was suspected wrong; most probably due to electrocardiographic interferences. In pigs, the patient state index and suppression ratio, as calculated by the Sedline monitor, could be influenced by the electrocardiographic activity contaminating the EEG trace, especially during otherwise isoelectric periods (strong EEG depression). Visual interpretation of the raw EEG and of the spectrogram remains necessary to identify such artefacts.

9.
Br J Anaesth ; 131(3): 510-522, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37453840

RESUMO

BACKGROUND: Suggested anaesthetic dose ranges do not differ by sex, likely because of limited studies comparing sexes. Our objective was to systematically synthesise studies with outcomes of unintended anaesthesia awareness under anaesthesia, intraoperative connected consciousness, time to emergence from anaesthesia, and dosing to achieve adequate depth of anaesthesia, and to compare between females and males. METHODS: Studies were identified from MEDLINE, Embase, and the Cochrane library databases until August 2, 2022. Controlled clinical trials (randomised/non-randomised) and prospective cohort studies that reported outcomes by sex were included. Results were synthesised by random effects meta-analysis where possible, or narrative form. RESULTS: Of the 19 749 studies identified, 64 (98 243 participants; 53 143 females and 45 100 males) were eligible for inclusion, and 44 citations contributed to meta-analysis. Females had a higher incidence of awareness with postoperative recall (33 studies, odds ratio 1.38, 95% confidence interval [CI] 1.09-1.75) and connected consciousness during anaesthesia (three studies, OR 2.09, 95% CI 1.04-4.23) than males. Time to emergence was faster in females, including time to eye-opening (10 studies, mean difference -2.28 min, 95% CI -3.58 to -0.98), and time to response to command (six studies, mean difference -2.84 min, 95% CI -4.07 to -1.62). Data on depth of anaesthesia were heterogenous, limiting synthesis to a qualitative review which did not identify sex differences. CONCLUSIONS: Female sex was associated with a greater incidence of awareness under general anaesthesia, and faster emergence from anaesthesia. These data suggest reappraisal of anaesthetic care, including whether similar drug dosing for females and males represents best care. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42022336087.


Assuntos
Anestesiologia , Anestésicos , Feminino , Humanos , Masculino , Estudos Prospectivos , Anestesia Geral , Anestesiologia/métodos
10.
Br J Anaesth ; 131(3): 523-530, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37422414

RESUMO

BACKGROUND: Sugammadex has been associated with increases in the bispectral index (BIS). We evaluated the effects of sugammadex administration on quantitative electroencephalographic (EEG) and electromyographic (EMG) measures. METHODS: We performed a prospective observational study of adult male patients undergoing robot-assisted radical prostatectomy. All patients received a sevoflurane-based general anaesthetic and a continuous infusion of rocuronium, which was reversed with 2 mg kg-1 of sugammadex i.v. BIS, EEG, and EMG measures were captured with the BIS Vista™ monitor. RESULTS: Twenty-five patients were included in this study. Compared with baseline, BIS increased at 4-6 min (ß coefficient: 3.63; 95% confidence interval [CI]: 2.22-5.04; P<0.001), spectral edge frequency 95 (SEF95) increased at 2-4 min (ß coefficient: 0.29; 95% CI: 0.05-0.52; P=0.016) and 4-6 min (ß coefficient: 0.71; 95% CI: 0.47-0.94; P<0.001), and EMG increased at 4-6 min (ß coefficient: 1.91; 95% CI: 1.00-2.81; P<0.001) after sugammadex administration. Compared with baseline, increased beta power was observed at 2-4 min (ß coefficient: 93; 95% CI: 1-185; P=0.046) and 4-6 min (ß coefficient: 208; 95% CI: 116-300; P<0.001), and decreased delta power was observed at 4-6 min (ß coefficient: -526.72; 95% CI: -778 to -276; P<0.001) after sugammadex administration. Neither SEF95 nor frequency band data analysis adjusted for EMG showed substantial differences. None of the patients showed clinical signs of awakening. CONCLUSIONS: After neuromuscular block reversal with 2 mg kg-1 sugammadex, BIS, SEF95, EMG, and beta power showed small but statistically significant increases over time, while delta power decreased.


Assuntos
Bloqueio Neuromuscular , Robótica , Adulto , Humanos , Masculino , Sugammadex/farmacologia , Prostatectomia , Eletroencefalografia , Androstanóis
11.
Br J Anaesth ; 131(2): 196-199, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37198033

RESUMO

Depth of anaesthesia monitors can fail to detect consciousness under anaesthesia, primarily because they rely on the frontal EEG, which does not arise from a neural correlate of consciousness. A study published in a previous issue of the British Journal of Anaesthesia showed that indices produced by the different commercial monitors can give highly discordant results when analysing changes in the frontal EEG. Anaesthetists could benefit from routinely assessing the raw EEG and its spectrogram, rather than relying solely on an index produced by a depth of anaesthesia monitor.


Assuntos
Anestesia , Humanos , Monitores de Consciência , Estado de Consciência , Eletroencefalografia/métodos
12.
Br J Anaesth ; 130(5): 536-545, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36894408

RESUMO

BACKGROUND: 'Depth of anaesthesia' monitors claim to measure hypnotic depth during general anaesthesia from the EEG, and clinicians could reasonably expect agreement between monitors if presented with the same EEG signal. We took 52 EEG signals showing intraoperative patterns of diminished anaesthesia, similar to those that occur during emergence (after surgery) and subjected them to analysis by five commercially available monitors. METHODS: We compared five monitors (BIS, Entropy-SE, Narcotrend, qCON, and Sedline) to see if index values remained within, or moved out of, each monitors' recommended index range for general anaesthesia for at least 2 min during a period of supposed lighter anaesthesia, as observed by changes in the EEG spectrogram obtained in a previous study. RESULTS: Of the 52 cases, 27 (52%) had at least one monitor warning of potentially inadequate hypnosis (index above range) and 16 of the 52 cases (31%) had at least one monitor signifying excessive hypnotic depth (index below clinical range). Of the 52 cases, only 16 (31%) showed concordance between all five monitors. Nineteen cases (36%) had one monitor discordant compared with the remaining four, and 17 cases (33%) had two monitors in disagreement with the remaining three. CONCLUSIONS: Many clinical providers still rely on index values and manufacturer's recommended ranges for titration decision making. That two-thirds of cases showed discordant recommendations given identical EEG data, and that one-third signified excessive hypnotic depth where the EEG would suggest a lighter hypnotic state, emphasizes the importance of personalised EEG interpretation as an essential clinical skill.


Assuntos
Anestesiologia , Monitorização Intraoperatória , Humanos , Anestesia Geral , Hipnóticos e Sedativos , Eletroencefalografia
13.
Int J Obstet Anesth ; 54: 103650, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36934515

RESUMO

Accidental awareness under general anaesthesia (AAGA) remains a major complication of anaesthesia. The incidence of AAGA during obstetric anaesthesia is high relative to other specialities. The use of processed electroencephalography (pEEG) in the form of "depth of anaesthesia" monitoring has been shown to reduce the incidence of AAGA in the non-obstetric population. The evidence for using pEEG to prevent AAGA in the obstetric population is poor and requires further exploration. Furthermore, pregnancy and disease states affecting the central nervous system, such as pre-eclampsia, may alter the interpretation of pEEG waveforms although this has not been fully characterised. National guidelines exist for pEEG monitoring with total intravenous anaesthesia and for "high-risk" cases regardless of technique, including the obstetric population. However, none of the currently available guidelines relates specifically to obstetric anaesthesia. Using pEEG monitoring for obstetric anaesthesia may also provide additional benefits beyond a reduction in risk of AAGA. These potential benefits include reduced postoperative nausea and vomiting, reduced anaesthetic agent use, and a shorter post-anaesthetic recovery stay. In addition, pEEG acts as a surrogate marker of cerebral perfusion, and thus as an additional monitor for impending cardiovascular collapse, as seen in amniotic fluid embolism. The subtle physiological and pathological changes in EEG activity that may occur during pregnancy are an unexplored research area in the context of anaesthetic pEEG monitors. We believe that the direction of clinical practice is moving towards greater use of pEEG monitoring and individualisation of anaesthesia.


Assuntos
Anestesia Geral , Anestesia Obstétrica , Anestésicos , Eletroencefalografia , Consciência no Peroperatório , Feminino , Humanos , Gravidez , Anestesiologia , Anestésicos/administração & dosagem , Consciência no Peroperatório/epidemiologia , Incidência
14.
Br J Anaesth ; 130(2): e317-e329, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36210184

RESUMO

BACKGROUND: Recent randomised controlled trials have failed to show a benefit in mortality by using processed electroencephalography (pEEG) to guide lighter anaesthesia. We performed a meta-analysis of mortality data from randomised trials of pEEG monitoring to assess the evidence of any protective effect of pEEG-guided light anaesthesia compared with deep anaesthesia in adults aged ≥18 yr. METHODS: Our study followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. In February 2022, we searched three databases (Cochrane CENTRAL, OVID Medline, EMBASE) for RCTs of pEEG monitoring that provided mortality data at 30 days, 90 days, and/or 1 yr or longer. RESULTS: We included 16 articles from 12 RCTs with 48 827 total participants. We observed no statistically significant mortality reduction with light anaesthesia compared with deep anaesthesia in patients aged ≥18 yr when all studies were pooled (odds ratio [OR]=0.99; 95% confidence interval (CI), 0.92-1.08). This result did not change significantly when analysing mortality at 30 days, 90 days, 1 yr or longer. We observed no mortality benefit for pEEG monitoring compared with usual care (OR=1.02; 95% CI, 0.89-1.18), targeting higher pEEG index values compared with lower values (OR=0.89; 95% CI, 0.60-1.32), or low pEEG index value alerts compared with no alerts (OR=1.02; 95% CI, 0.41-2.52). CONCLUSIONS: pEEG-guided lighter anaesthesia does not appear to reduce the risk of postoperative mortality. The absence of a plausible rationale for why deeper anaesthesia should increase mortality has hampered appropriate design of definitive clinical trials. CLINICAL TRIAL REGISTRATION: CRD42022285195 (PROSPERO).


Assuntos
Anestesia Geral , Coração , Adulto , Humanos , Período Pós-Operatório , Ensaios Clínicos Controlados Aleatórios como Assunto
15.
Cureus ; 14(9): e29180, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36282982

RESUMO

BACKGROUND: Bispectral Index (BIS) is used to monitor anesthetic depth and is a useful instrument to keep a check on intraoperative awareness. But there are various situations in which it shows false readings. Our aim of the study was to observe the changes in BIS value with steep Trendelenburg position, which is usually done, in robotic pelvic surgeries. METHODS: We included 100 patients in our study who underwent robotic prostatectomies and hysterectomies. After anesthetizing the patient, the patient's heart rate, systolic blood pressure, mean arterial pressure, end-tidal desflurane, end-tidal CO2, and BISwere recorded at three min. intervals, for 15 minutes before and 15 minutes after the Trendelenburg position without surgical stimulus. RESULTS: We found a significant increase in BIS values (p <0.05) after the change of position from supine to steep Trendelenburg. Heart rate, systolic blood pressure, and mean arterial pressure were almost constant. CONCLUSION: Our study concluded that the BIS value increases when patients were shifted from the supine to Trendelenburg position, which might raise the concern of a decrease in anesthetic depth.

16.
Sensors (Basel) ; 22(16)2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-36015860

RESUMO

This paper proposed a new depth of anaesthesia (DoA) index for the real-time assessment of DoA using electroencephalography (EEG). In the proposed new DoA index, a wavelet transform threshold was applied to denoise raw EEG signals, and five features were extracted to construct classification models. Then, the Gaussian process regression model was employed for real-time assessment of anaesthesia states. The proposed real-time DoA index was implemented using a sliding window technique and validated using clinical EEG data recorded with the most popular commercial DoA product Bispectral Index monitor (BIS). The results are evaluated using the correlation coefficients and Bland-Altman methods. The outcomes show that the highest and the average correlation coefficients are 0.840 and 0.814, respectively, in the testing dataset. Meanwhile, the scatter plot of Bland-Altman shows that the agreement between BIS and the proposed index is 94.91%. In contrast, the proposed index is free from the electromyography (EMG) effect and surpasses the BIS performance when the signal quality indicator (SQI) is lower than 15, as the proposed index can display high correlation and reliable assessment results compared with clinic observations.


Assuntos
Anestesia , Eletroencefalografia , Monitores de Consciência , Eletroencefalografia/métodos , Eletromiografia , Análise de Ondaletas
17.
J Int Med Res ; 50(8): 3000605221118682, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35971317

RESUMO

Previous studies have attempted to determine the depth of anaesthesia with different anaesthetic agents using electroencephalogram (EEG) measurements with variable success. Measuring depth of anaesthesia is confounded by the complexity of the EEG and the fact that different agents create different pattens. A narrative review was undertaken to examine the available research evidence on the effect and reliability of spectral edge frequency (SEF) for assessing the depth of anaesthesia in adult patients under general anaesthesia. A systematic search of the PubMed®, Scopus®, CINAHL and Cochrane databases identified six randomized controlled trials and five observational studies. The findings of these studies suggest that SEF varies according to the anaesthetic drugs used. Remifentanil and age are two factors that can affect SEF, while other opioids and benzodiazepine (administered separately) seem to have no effect. No patients experienced intraoperative awareness. However, this does not indicate that SEF can provide full protection against it and the number of articles in which intraoperative awareness was studied was too small to afford any certainty. None of the studies demonstrated a reliable SEF interval associated with adequate general anaesthesia. SEF must be adapted to the anaesthetic drug used, the patient's age and state while under general anaesthesia.


Assuntos
Anestésicos , Consciência no Peroperatório , Adulto , Anestesia Geral , Anestésicos/farmacologia , Eletroencefalografia , Humanos , Reprodutibilidade dos Testes
18.
Health Inf Sci Syst ; 10(1): 10, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35685297

RESUMO

The requirement for anaesthesia during modern surgical procedures is unquestionable to ensure a safe experience for patients with successful recovery. Assessment of the depth of anaesthesia (DoA) is an important and ongoing field of research to ensure patient stability during and post-surgery. This research addresses the limitations of current DoA indexes by developing a new index based on electroencephalography (EEG) signal analysis. Empirical wavelet transformation (EWT) methods are employed to extract wavelet coefficients before statistical analysis. The features Spectral Entropy and Second Order Difference Plot are extracted from the wavelet coefficients. These features are used to train a new index, SSEDoA, utilising a Support Vector Machine (SVM) with a linear kernel function. The new index accurately assesses the DoA to illustrate the transition between different anaesthetic stages. Testing was undertaken with nine patients and an additional four patients with low signal quality. Across the nine patients we tested, an average correlation of 0.834 was observed with the Bispectral (BIS) index. The analysis of the DoA stage transition exhibited a Choen's Kappa of 0.809, indicative of a high agreement.

19.
J Clin Monit Comput ; 36(3): 675-685, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33860876

RESUMO

The BIS and Entropy systems are used as indicators of anaesthetic drug effect, and can also record EEGs in digital form. A number of studies have used such recordings for analysis, even though information about bandwidth and fidelity has not been provided by the manufacturers. In this study we consider these systems purely as EEG recording devices, and evaluate their suitability for quantitative analysis. Using a calibrated electronic testing system, we played an artificial test signal of known amplitude with frequency varying from 0.01 to 400 Hz into the BIS and Entropy EEG systems, and saved the recording in each of their supported recording modes. The amplitude of the recording at each frequency was then used to derive the frequency response curves, as well as the 3 dB and 0.5 dB points for each mode. There are important differences between the various BIS and Entropy recordings. The BIS 256 Hz and the Entropy 400 Hz recordings are broadly comparable, although Entropy has a slightly reduced response above 50 Hz and below 1 Hz. The BIS 128 Hz recording has a somewhat reduced bandwidth, due to its relatively low sampling rate. The Entropy 100 Hz recording in the Datex-Ohmeda S/5 monitor has a flawed implementation, leading to aliasing of signals over 50 Hz and potential distortion of the recording, while in the GE Carescape it has an uneven response and a narrowed bandwidth. Consequently, it is important to know which specific host monitor was used when an Entropy 100 Hz recording was made. In summary, the choice of recording device and host monitor may affect the results of some quantitative EEG analysis, and some previously published studies may need to be re-evaluated.


Assuntos
Anestésicos , Monitorização Intraoperatória , Eletroencefalografia/métodos , Entropia , Humanos , Monitorização Intraoperatória/métodos , Monitorização Fisiológica
20.
BMC Anesthesiol ; 21(1): 294, 2021 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-34814841

RESUMO

BACKGROUND: In this study, we aimed to analyse survey data to explore two different hypotheses; and for this purpose, we distributed an online survey to Chinese anaesthesiologists. The hypothetical questions in this survey include: (1) Chinese anaesthesiologists mainly use the depth of anaesthesia (DoA) monitors to prevent intraoperative awareness and (2) the accuracy of these monitors is the most crucial performance factor during the clinical daily practice of Chinese anaesthesiologists. METHODS: We collected and statistically analysed the response of a total of 12,750 anesthesiologists who were invited to participate in an anonymous online survey. The Chinese Society of Anaesthesiologists (CSA) trial group provided the email address of each anaesthesiologist, and the selection of respondents was random from the computerized system. RESULTS: The overall response rate was 32.0% (4037 respondents). Only 9.1% (95% confidence interval, 8.2-10.0%) of the respondents routinely used DoA monitors. Academic respondents (91.5, 90.3-92.7%) most frequently used DoA monitoring to prevent awareness, whereas nonacademic respondents (88.8, 87.4-90.2%) most frequently used DoA monitoring to guide the delivery of anaesthetic agents. In total, the number of respondents who did not use a DoA monitor and whose patients experienced awareness (61.7, 57.8-65.6%) was significantly greater than those who used one or several DoA monitors (51.5, 49.8-53.2%). Overall, the crucial performance factor during DoA monitoring was considered by 61.9% (60.4-63.4%) of the respondents to be accuracy. However, most respondents (95.7, 95.1-96.3%) demanded improvements in the accuracy of the monitors for DoA monitoring. In addition, broad application in patients of all ages (86.3, 85.2-87.4%), analgesia monitoring (80.4, 79.2-81.6%), and all types of anaesthetic agents (75.6, 74.3-76.9%) was reported. In total, 65.0% (63.6-66.5%) of the respondents believed that DoA monitors should be combined with EEG and vital sign monitoring, and 53.7% (52.1-55.2%) believed that advanced DoA monitors should include artificial intelligence. CONCLUSIONS: Academic anaesthesiologists primarily use DoA monitoring to prevent awareness, whereas nonacademic anaesthesiologists use DoA monitoring to guide the delivery of anaesthetics. Anaesthesiologists demand high-accuracy DoA monitors incorporating EEG signals, multiple vital signs, and antinociceptive indicators. DoA monitors with artificial intelligence may represent a new direction for future research on DoA monitoring.


Assuntos
Anestesia/estatística & dados numéricos , Anestesiologistas/estatística & dados numéricos , Monitorização Intraoperatória/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Adulto , Anestesia/métodos , Anestésicos/administração & dosagem , Inteligência Artificial , Atitude do Pessoal de Saúde , China , Monitores de Consciência , Feminino , Pesquisas sobre Atenção à Saúde , Humanos , Consciência no Peroperatório/prevenção & controle , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA