Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 969
Filtrar
1.
Int J Implant Dent ; 10(1): 36, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39012381

RESUMO

PURPOSE: This study aims to evaluate the amount of distortion using computer-guided implant surgery with 3D printed surgical guides in limited edentulous spaces. MATERIALS AND METHODS: 25 bone level self-tapping implants (Straumann® BL and BLT) were randomly inserted in either distal or intercalary posterior mandibular edentulism using a fully digital protocol and 3D printed surgical guides. Amount of inaccuracy was evaluated after superimposing the 3 coordinates of virtually planned and final implant images, which were obtained using intra-oral scans and scan bodies. Four evaluation parameters were considered: origo-displacement, error depth, apical displacement and angle between the planned and the placed implant. RESULTS: The average of distortion was 0.71 mm for the origo-displacement, 0.36 mm for the error depth, 0.52 mm for the horizontal displacement and 3.34º for the error angle. CONCLUSION: The major reason of exclusion was CBCT artifacts. Results of this study were aligned with the results of previous studies concerning partially edentulous spaces. CAD/CAM manufacturing process did not result in significant distortion whilst the biggest part of distortions originated from the surgical process. The learning curve in computer-guided implant surgery presented an important source of inaccuracy.


Assuntos
Arcada Parcialmente Edêntula , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Estudos Prospectivos , Arcada Parcialmente Edêntula/cirurgia , Arcada Parcialmente Edêntula/diagnóstico por imagem , Implantação Dentária Endóssea/métodos , Implantação Dentária Endóssea/instrumentação , Feminino , Masculino , Pessoa de Meia-Idade , Impressão Tridimensional , Implantes Dentários , Tomografia Computadorizada de Feixe Cônico
2.
J Prosthodont ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38953541

RESUMO

PURPOSE: To assess the accuracy of complete maxillary and mandibular edentulous arch scans obtained using two different intraoral scanners (IOSs), with and without scanning aids, and to compare these results to those obtained using conventional impression methods. MATERIALS AND METHODS: Two IOSs were used (TRIOS 4 [TRI] and Emerald S [EMR]) to scan maxillary and mandibular typodonts. The typodonts were scanned without scanning aids [TRI_WSA and EMR_WSA groups] (n = 10). The typodonts were then scanned under four scanning aid conditions (n = 10): composite markers [TRI_MRK and EMR_MRK groups], scanning spray [TRI_SPR and EMR_SPR groups], pressure indicating paste [TRI_PIP and EMR_PIP groups], and liquid-type scanning aid [TRI_LQD and EMR_LQD groups]. Conventional impressions of both arches were also made using irreversible hydrocolloids in stock trays [IHC] and using polyvinyl siloxane (PVS) impression material in custom trays (n = 10) which were digitized using a laboratory scanner. Using a metrology software program, all scans were compared to a reference scan in order to assess trueness and to each other to assess precision. Trueness and precision were expressed as the root mean square (RMS) of the absolute deviation values and the statistical analysis was modeled on a logarithmic scale using fixed-effects models to meet model assumptions (α = 0.05). RESULTS: The main effect of arch (p = 0.004), scanner (p < 0.001), scanning aid (p = 0.041), and the interaction between scanner and scanning aid (p = 0.027) had a significant effect on mean RMS values of trueness. The arch (p = 0.015) and scanner (p < 0.001) had a significant effect on the mean RMS values of precision. The maxillary arch had better accuracy compared to the mandible. The TRIOS 4 scanner had better accuracy than both the Emerald S scanner and conventional impressions. The Emerald S had better precision than conventional impressions. The scanning spray and liquid-type scanning aids produced the best trueness with the TRIOS 4 scanner, while the liquid-type scanning aid and composite markers produced the best trueness for the Emerald S scanner. CONCLUSION: The scanned arch and the type of scanner had a significant effect on the accuracy of digital scans of completely edentulous arches. The scanning aid had a significant effect on the trueness of digital scans of completely edentulous arches which varied depending on the scanner used.

3.
J Oral Implantol ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38962854

RESUMO

BACKGROUND: Bone expansion is where the existing bone at the implant site is split and separated to create a gap to widen it. This article introduces a novel concept of bone expansion for the ultra-thin alveolar ridges to place dental implants with zero wastage of existing natural bone in long-term edentulous arches. Instead of using twist drills and piezo surgery kits, the bone is split with a surgical scalpel blade to prevent natural bone wastage. METHODS: The split will help to expand the bone horizontally by using expanders to accommodate the smaller diameter implants. This technique was applied to 12 individuals to rehabilitate their atrophic edentulous mandibles to facilitate the implant-supported overdentures, and it revealed that all the cases achieved successful osseointegration after placing implants following this method. CONCLUSIONS: The "Scalp-Spilt Technique" is a promising technique for providing implant- retained or implant-supported prostheses over ultra-thin edentulous alveolar ridges.

4.
J Adv Prosthodont ; 16(3): 139-150, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38957291

RESUMO

PURPOSE: The purpose of this diagnostic study was to assess the accuracy and time efficiency of a digital method to draw the denture foundation extension outline on preliminary casts compared with the conventional technique. MATERIALS AND METHODS: A total of 28 preliminary edentulous casts with no anatomical landmarks were digitized using a laboratory scanner. The outlining of the entire basal seat of the denture was performed on preliminary casts and digitized. Casts with no extension outline were digitized and outlines were drawn using software (DWOS, Straumann). The accuracy of the extension outlined between both techniques was evaluated in the software (GOM Inspect; GOM GmbH) by file superimposition. Specificity and sensitivity tests were applied to measure accuracy. The paired t-test (95% CI) was used to compare the mean total area and the working time. RESULTS: The accuracy ranged from 0.57 to 0.92. The buccal and labial frenulum showed a lower value in the maxilla (0.57); while the area between the retromolar pad and buccal frenulum (0.64) showed a lower score in the mandible. The maxillary denture foundation and the working time for both arches were significantly longer for the digital method (P < .001). CONCLUSION: The denture foundation extension outline exhibited a sufficiently excellent accuracy for the digital method, except for the maxillary anterior region. However, the digital method required a longer working time.

5.
J Prosthodont ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38985142

RESUMO

PURPOSE: This prospective case series aimed to investigate the effect of vertical alveoloplasty on the changes in keratinized mucosa width (KMW) following full-arch immediate implant placement and rehabilitation. MATERIALS AND METHODS: A total of 17 potential edentulous patients were enrolled and received implant placement and full-arch implant-supported immediate rehabilitations. The main outcome was to analyze the effect of vertical alveoloplasty on the changes in KMW. The amount of vertical alveoloplasty during implant surgery as well as the changes in KMW at buccal aspects from the day of surgery to 6 months post-surgery were recorded on the implant-level using a periodontal probe. The secondary outcome was to analyze the other possible factors that affected the changes in KMW. The included factors were the initial KMW, the distribution of implants in the maxilla and mandible, the distribution of implants in the anterior and posterior regions, the distribution of implants in extraction sockets and healed ridges, and gender. Mann-Whitney non-parametric tests and multiple linear regression adjusted by generalized estimating equations (GEE) were used to statistically analyze the data. RESULTS: A total of 121 implant positions were analyzed. The KMW was 4.1± 2.0 mm on the day of the surgery and 4.1± 1.7 mm 6 months post-surgery. The mean changes in KMW following 6 months were -0.1± 1.6 mm (p = 0.824). From the results of GEE, the vertical amount of alveoloplasty had no significant effect on changes in KMW. Both initial KMW and the distribution of implants in the anterior and posterior regions had significant impacts on the changes in KMW (p < 0.0001). CONCLUSION: The amount of vertical alveoloplasty during implant surgery has no significant impact on the KMW. The KMW remained stable from baseline to 6 months after alveoloplasty, implant placement, and immediate rehabilitations in potential edentulous arches. The initial KMW and the distribution of implants in the anterior and posterior regions were the possible factors affecting changes in KMW.

6.
J Indian Soc Periodontol ; 28(1): 106-112, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38988954

RESUMO

Objective: The objective is to compare and evaluate the hard and soft tissue parameters by using short and standard long implants with sinus lifting in the posterior maxilla. Materials and Methods: Eleven patients with complaints of missing upper back teeth were enrolled in the study for implant-supported rehabilitation and were categorized into two groups: Group long (GL): longer implant (>8 mm) placement, preceded by Sinus Augmentation. Group short (GS): short implant (≤8 mm) placement, without sinus augmentation. The primary outcome measured was cumulative survival rate (CSR) in the compromised partial edentulous posterior maxilla. Secondary outcomes measured were implant stability (IS), marginal bone level alterations (MBL), pocket probing depth (PPD), crown-to-implant ratio, and any complications. Results: The difference in CSR between the groups was not statistically significant (P = 0.317). High stability was achieved immediately after the placement of the implants, in both groups (GS: 64 ± 4.07, GL: 65.58 ± 9.75); this difference in the mean ISQ (IS quotients) values was not found to be statistically significant at implant placement (P = 0.7). The mean MBL reported in the study at the end of 12 months of prosthesis function was - 0.762 ± 0.48 mm and - 0.7 ± 0.34 mm for GS and GL, respectively. The mean PPD measurements in GS and GL groups were 1.917 ± 0.68 mm and 1.833 ± 0.38 mm, respectively, and it was not statistically significant (P = 0.8). Conclusion: Within the limitations of the present study, the obtained results indicate that short implants provided a similar clinical and radiographic performance compared to long implants placed in combination with a sinus augmentation procedure (lateral window) up to 12 months after prosthetic loading.

7.
J Clin Med ; 13(13)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38999204

RESUMO

Background/Objectives: The insertion of dental implants using dynamic 3D navigated surgery while applying immediate function protocols for full-arch rehabilitations warrants further research. This study aimed to evaluate the outcomes of All-on-4® rehabilitations using 3D Dynamic navigated surgery (X-Guide™). Methods: This study included 10 patients (women: 7; men: 3; average age: 59.9 years) rehabilitated with full-arch prostheses through the All-on-4® concept, with 48 dental implants inserted using navigated surgery. The primary outcome evaluation was prosthetic/implant cumulative survival (CS), estimated using life tables. Secondary outcome evaluations were marginal bone resorption (MBR), biological complications, and mechanical complications. The evaluation parameters were measured between 1 and 3 years. Results: No patients were lost to follow-up. Two implants (4.2%) were lost in one patient (10%) with smoking habits, resulting in an implant CS rate of 95.8%. The average MBR was 0.51 mm ± 0.62 mm at the 1-year follow-up. The incidence rate of mechanical complications was 40% (n = 4 patients), all occurring in provisional prosthesis. No biological complications were registered. The patients maintained their prostheses in function throughout the follow-up of the study. Conclusions: Within the limitations of this study and based on the results, it can be concluded that the insertion of dental implants assisted by dynamic navigation for full-arch rehabilitation through the All-on-4® concept may be a valid treatment alternative in the short-term follow-up. However, more studies are necessary to validate this treatment modality.

8.
Artigo em Inglês | MEDLINE | ID: mdl-39031991

RESUMO

OBJECTIVES: Individual-level social determinant of health (SDOH) measures alone may insufficiently explain disparities in edentulism among seniors. Therefore, the authors examined the correlation of census tract-level SDOH and residential racial segregation measures with edentulism in Californian adults aged ≥65 years old. METHODS: Explanatory variables were obtained from Healthy Places Index (HPI), the National Cancer Institute and diversitydatakids.org. The edentulism outcome variable was obtained from CDC's PLACES small area estimates from the 2018 Behavioral Risk Factor Surveillance System data. Pearson and Spearman rank correlations were estimated. Multiple linear regression and multi-collinearity evaluations were performed. The Global Moran's I statistic assessed partial autocorrelation within census tracts. RESULTS: Pearson and Spearman correlations were similar, supporting robustness. HPI, an area measure of advantage, strongly negatively correlated with edentulism prevalence [correlation coefficient: -0.87; 95% confidence interval (CI): -0.87, -0.86]. A change of 1.0 in HPI corresponded to an estimated decrease in edentulism prevalence of 5.9% (linear model adjusted R2 = 0.78). Racially segregated census tracts with Hispanics or Blacks alone were positively correlated with edentulism prevalence [0.60, 95% CI: 0.58, 0.62; and 0.33, 95% CI: 0.31, 0.35, respectively]. The converse was seen in census tracts with non-Hispanic Whites alone [-0.57, 95% CI: -0.58, -0.55]. Global Moran's I statistic for edentulism (0.13) and HPI scores (0.19) were significant (both p < .001) indicating geospatial autocorrelation. CONCLUSIONS: Higher disadvantage and minority racial segregation within census tracts were positively correlated with edentulism prevalence. Future research and policy should consider possible interventions improving SDOH to reduce oral health inequities.

9.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38832462

RESUMO

With the rapid development of implant techniques and digital technology, digital impressions have become a commonly used impression method in implant restoration. At present, the accuracy of intraoral digital impressions directly applied to implant-supported full-arch prostheses remains inadequate, which is due to the high accuracy requirement of full-arch implant impressions, while there are still technical challenges in intraoral digital impressions about recognition and stitching. In this regard, scholars have proposed a variety of scanning strategies to improve the accuracy of intraoral scan, including mucosal modifications, auxiliary devices and novel scan bodies. At the same time photogrammetry, as a new digital impression technique, has been developing steadily and exhibits promising accuracy. This article reviews the research progress on the accuracy of edentulous full-arch implant impressions and techniques which can improve the accuracy of intraoral digital impressions, to provide reference for clinical application.

10.
J Clin Med ; 13(12)2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38929921

RESUMO

Background: The improvement of oral-health-related quality of life (OHRQoL) with different types of prosthesis for completely edentulous jaws in the elderly population is a critical factor in clinical decision making for these vulnerable patients. This review aims to evaluate the changes in OHRQoL after treatment with different types of full-arch prostheses in the elderly edentulous population to determine the prostheses that result in the greatest improvement in OHRQoL. Materials and Methods: Clinical studies of different types of full-arch prostheses that measured the OHRQoL in edentulous patients 60 years or older were searched for in the PubMed, Embase and Scopus electronic databases, with additional hand searching to summarize the outcomes of the selected studies. Result: Among the 302 identified studies, 10 studies were selected. A total of 504 patients wearing 133 complete dentures, 372 implant overdentures and 39 fixed prostheses were assessed among the selected studies. The overall OHIP and GOHAI scores were evaluated at baseline and in the 3rd, 6th, 12th and 18th months of treatment with the respective prostheses. The improved OHRQoL with overall OHIP scores associated with conventional dentures were 9.21-12.5% from the 3rd month to 1 year after treatment, whereas those associated with implant overdentures and full-arch fixed prosthesis were 9-25.26% at 1 year and 18.53-26.79 at the 18th-month follow-up, respectively. The increased overall GOHAI scores were 21.3-25.43% for conventional dentures, 36.82-41.32% for implant overdentures and 39.48-42.83% for full-arch fixed prosthesis from the 3rd month to the 6th-month follow-up. Conclusion: In general, the improvement in OHRQoL after rehabilitation with implant overdentures declined at one year, and that with full-arch fixed prosthesis declined at the 18th-month follow-up; meanwhile, the OHRQoL associated with conventional dentures improved stably up to one year, but the implant-supported prostheses resulted in an obviously greater improvement in the OHRQoL than that obtained with conventional dentures. However, studies with longer follow-up periods are still required to evaluate the long-term clinical effectiveness.

11.
J Dent ; 148: 105136, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38885734

RESUMO

OBJECTIVES: Ultrasound (US) reveals details for diagnosing soft- and hard-tissue dimensions around teeth, implants, and the edentulous ridge, not seen in 2D radiographs. Co-registering free-hand US scans with other 3D modalities presents reliability challenges. This study first aims to develop and validate a registration method to longitudinally reproduce US images of the jawbone on a simulator. In addition, it also evaluates the degree of the anatomical match in humans between US images acquired by the proposed registration method and the commonly used freehand acquisitions in comparison to cone beam computed tomography (CBCT) and intra-oral optical scan (IOS), used as references. METHODS: A previously introduced ultrasound phantom was employed as a CBCT-US hybrid, suitable for training and technique development of US guides in edentulous ridges. After establishing feasibility in the phantom, the methodology was validated in a cohort of 24 human subjects (26 cases). Soft tissues were delineated on US and IOS, and hard tissues on US and CBCT. US accuracy and repeatability from both guided and freehand scans (non-guided) was assessed as the average distance between US and the references. RESULTS: Guided US images resembled the references more closely than freehand (non-guided) scans. Notably, delineation of soft and hard tissues was significantly more accurate when employing guides. In the phantom, guided scans exhibited an absolute mean deviation of 81.8 µm for gingiva and 90.4 µm for bone, whereas non-guided scans showed deviations of 150.4 µm and 177.2 µm, respectively. Similarly, in vivo, guided US outperformed non-guided US, with gingiva deviations of 125 µm and 196 µm, and bone deviations of 354 µm and 554 µm, respectively. CONCLUSIONS: By using a registration method, guided US scans improved repeatability and accuracy of mapping hard and soft tissue of the edentulous ridge when compared to non-guided scans. CLINICAL RELEVANCE: This guided US imaging method could lay the foundation for longitudinal evaluation of tissue behavior and dimensional changes with improved accuracy.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38867397

RESUMO

OBJECTIVE: This study explored factors affecting speech improvement in patients with an edentulous maxilla after the delivery of a complete-arch implant-supported fixed dental prosthesis (IFDP). MATERIALS AND METHODS: Patients who had received IFDP for edentulous maxilla were enrolled, and various potential speech improvement-related factors were considered, including patient demographics, anterior residual bone volume, preoperative facial features, preoperative acoustic parameters, and adaptation time. Acoustic analysis and perceptual ratings were used to assess three fricatives [s], [f], and [ɕ]. Correlation and regression analyses were conducted to assess the association between changes in fricatives and potential factors (α = .05). RESULTS: The study included 50 patients (18 females and 32 males, aged 50.62 ± 15.71 years, range 19-76). Significant correlations were found among the change in the center of gravity (ΔCoG) of [s] and anterior residual bone volume, zygomatic implants number and proportion (p < .05). These correlations were largely mirrored in the perceptual score (ΔPS) changes. After controlling for age, sex, preoperative acoustic parameters, and adaptation time, the ΔCoG and ΔPS of fricatives were mainly correlated with the anterior residual bone volume, preoperative acoustic parameters, and adaptation time. CONCLUSION: Speech improvements post-IFDP delivery are mainly related to preoperative speech characteristics, anterior residual bone volume, and adaptation time. The residual bone volume's impact on consonants varies with specific articulatory gestures. This study provides insights into forecasting speech outcomes following IFDP restoration and provides recommendations and methods for data collection in developing future prediction models.

13.
BMC Oral Health ; 24(1): 709, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38898433

RESUMO

BACKGROUND: Edentulism remains a major disability worldwide, especially among the elderly population, although the prevalence of complete edentulism has declined over the last decades. In Uganda, the prevalence of edentulism in people aged 20 years and above is 1.8%. The therapy for edentulous patients can be realized through the use of conventional removable complete dentures, implant-supported prostheses, and computer-aided design and computer-aided manufacturing (CADCAM), however, the provision of removable complete dentures continues to be the predominant rehabilitation for edentulous patients. However, no published study has explored the lived experiences with removable complete dentures among the Ugandan population. The aim of the present study was to explore patients' lived experiences on the usage of removable complete dentures among Ugandan edentulous patients attending Makerere University Dental Hospital. METHODS: This was a qualitative study approach using purposive sampling. Fifteen (15) respondents were selected across social demographics. Interviews were recorded and transcribed and themes were generated to draw a deeper meaning to the usage of removable complete dentures. A qualitative statistical package, Atlas Ti software was used to generate themes from the interviews followed by an interpretation of the generated data and the results were presented as text and in a table. RESULTS: The reported key positive experiences due to removable complete denture rehabilitation were the improvement in speech, eating ability, regaining good facial appearance, better oral hygiene management, self-esteem and confidence to smile in public, and a feeling of completeness. However, respondents complained of pain and discomfort due to the looseness of dentures, inability to eat certain foods, and regular cleaning of dentures. The respondents did not go through proper informed consent processes before getting removable complete dentures. CONCLUSION: The study found that patients were satisfied with their removable complete dentures rehabilitation due to the positive experiences registered, such as the ability to eat and talk well, and restoration of self-esteem, all of which improved their quality of life. However, they experience pain and discomfort due to the looseness of dentures.


Assuntos
Prótese Total , Boca Edêntula , Humanos , Uganda , Boca Edêntula/psicologia , Boca Edêntula/reabilitação , Feminino , Masculino , Prótese Total/psicologia , Pessoa de Meia-Idade , Idoso , Pesquisa Qualitativa , Adulto , Qualidade de Vida
14.
J Oral Implantol ; 50(3): 266-276, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38839070

RESUMO

Patient satisfaction and quality of life are integral to assessing oral health care quality. For many Americans still using conventional complete dentures (CDs) or implant-retained mandibular overdentures (IODs), it remains essential to consider improving their oral health outcomes and quality of life. Due to inexperienced student dentists providing dental care to dental school patients, patient grievances are generally considered a problem. Patient feedback and satisfaction have proven valuable resources for monitoring and improving patient safety. While CDs and IODs are the 2 leading treatment options for edentulism, more comparative studies in the literature need to compare their outcomes in a school setting. The research question that guided this comparative analysis was, "Is patient satisfaction and quality of life affected by the type of prostheses and provider?" A validated questionnaire was mailed to 520 individuals selected from records of patients who had received treatment for edentulous mandible at a student prosthodontic clinic at the University of Kentucky College of Dentistry from 2014 to 2016 with at least 1 year of follow-up time. A validated questionnaire for edentulous patients based on the Oral Health Impact Profile (OHIP-19) was used. In addition, information on patients' oral health-related quality of life, including questions related to the edentulous patients' satisfaction with their dentures, was collected. The response rate was 33% (N = 171). The study's findings confirm previous findings, suggesting that IODs may significantly impact oral health-related quality of life. Data show that 76% of the IOD group reported improvement in experience when using the implants to retain the mandibular denture. However, there were no statistically significant differences in the OHIP scores between overall CD and IOD patient groups. Males with IODs had lower physical pain, limitations, and disability scores than males with CD. However, females with IODs reported more significant concerns associated with a social disability and handicap domains. Comparing users who had experiences with both treatment options, this study discerned essential characteristics that contribute to increased patient satisfaction with IODs and identified significance in outcomes by gender. These findings guide prosthodontic practitioners' patient care practices and identify a continuing need to discuss CD and IOD treatment protocols within dental school curricula.


Assuntos
Prótese Dentária Fixada por Implante , Prótese Total , Revestimento de Dentadura , Satisfação do Paciente , Qualidade de Vida , Faculdades de Odontologia , Humanos , Masculino , Feminino , Prótese Dentária Fixada por Implante/psicologia , Pessoa de Meia-Idade , Inquéritos e Questionários , Idoso , Clínicas Odontológicas , Adulto , Arcada Edêntula/reabilitação
15.
Artigo em Inglês | MEDLINE | ID: mdl-38822688

RESUMO

OBJECTIVES: To evaluate the survival rates and marginal bone loss of narrow-diameter titanium-zirconium implants supporting complete maxillary and mandibular overdentures up to 3 years after loading. MATERIALS AND METHODS: Ten completely edentulous patients who were dissatisfied with their complete dentures were enrolled. Two narrow-diameter implants were placed in the canine region of the maxilla and mandible. After second-stage surgery, implant-supported overdentures (palatal-free) attached by parallel alignable stud-attachments were placed. Patients were followed periodically for up to 36 months. Standardized radiographs were taken at baseline, 12 and 36 months to analyze mean marginal bone level changes around the implants. RESULTS: The Kaplan-Meier survival rates were 100% for mandibular and 68.0% (SE ± 10.9%) for maxillary implants at 36 months (p = .008). Six maxillary implants failed after loading; no mandibular implants were lost. Five implants failed due to loss of osseointegration. One implant fractured. The mean marginal bone level changes around the analyzed implants (n = 28, 9 patients) were -0.71 ± 0.82 mm in the mandible and -2.08 ± 1.52 mm in the maxilla at the 36-month follow-up. The difference in marginal bone level changes between the maxilla and mandible was significant (p = .019) at the 12- and 36-month follow-ups. CONCLUSION: Two narrow-diameter titanium-zirconium implants with stud-attachments showed a highly satisfactory outcome in the mandible. The maxillary implants showed a high failure rate and significantly more bone loss over time than the mandibular implants. The minimal concept of two implants and an overdenture should be limited to the edentulous mandible.

16.
Saudi Dent J ; 36(5): 815-820, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38766286

RESUMO

Objectives: This study aims to compare differences in mandibular canal (MC) location between dentate and edentulous ridges, in the second premolar region as well as the first, second, and third molar regions using cone beam computed tomography (CBCT) of Arabic and Kurdish Iraqi populations. Materials and Methods: CBCT images of 400 subjects (200 Arabs, 200 Kurds) were collected from radiological archives. RadiAnt DICOM software (Medixant, Poland) was used for image analyses. Measurements were performed from MC to buccal and lingual alveolar crests and to buccal, lingual, and inferior aspect of the mandible for both dentate and edentulous ridges. Additionally, distance to the most superior aspect of residual edentulous ridge were performed. Independent t-test and Mann-Whitney U Test were performed utilising SPSS v.26. Results: Distances from MC to buccal and lingual alveolar crests were consistently lower in edentulous ridge compared to dentate ridge across all teeth regions. Distances to lingual and inferior border of the mandible were higher in edentulous ridge compared to dentate ridge of all teeth regions. Distances to buccal surface of the mandible varies with fluctuations of dentate and edentulous ridges displaying higher measurements. Distance to superior aspect of residual edentulous ridge revealed mean values in the range of 13.45 to 15.69 mm in Arabs and 13.96 to 16.37 mm in Kurds. Conclusions: Discrepancy in vertical position of MC was observed between dentate and edentulous ridges within Arab and Kurd populations. Horizontal position of MC was unaffected by tooth loss and found to be closer to lingual surface of all molars. The residual alveolar ridge was sufficient to accommodate the common length and width of dental implants. Clinical significance: The findings could play a crucial role in planning surgical interventions of the mandible, helping to prevent complications that might arise due to inadequate preoperative assessments.

17.
Oral Health Prev Dent ; 22: 181-188, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38713458

RESUMO

PURPOSE: The objective of the present systematic review and meta-analysis was to assess randomised controlled trials (RCTs) which assessed the efficacy of mini dental implants (MDIs) and standard-diameter implants (SDIs) in retaining mandibular overdentures (MO). MATERIALS AND METHODS: The focused question was "Is there a difference in the mechanical stability between MDIs and SDIs in retaining MO?" Indexed databases were searched up to and including November 2023 using different keywords. Boolean operators were used during the search. The literature was searched in accordance with the PRISMA guidelines. The PICO characteristics were: patients (P) = individuals with complete mandibular dentures requiring dental implants; Intervention (I) = placement of MDIs under mandibular dentures; Control (C) = placement of SDIs under mandibular dentures; Outcome (O) = comparison of stability between MDIs and SDIs in supporting mandibular dentures. Only RCTs were included. Risk of bias (RoB) was assessed using the Cochrane RoB tool. RESULTS: Five RCTs were included. The numbers of participants ranged between 45 and 120 edentulous individuals wearing complete mandibular dentures. The mean age of patients ranged between 59.5 ± 8.5 and 68.3 ± 8.5 years. The number of MDIs and SDIs ranged between 22 and 152 and 10 and 80 implants, respectively. The follow-up duration ranged between one week and 12 months. Three RCTs reported an improvement in the quality of life (QoL) of all patients after stabilisation of mandibular dentures using MDIs or SDIs. In one RCT, peri-implant soft tissue profiles were comparable between MDIs and SDIs at the 1-year follow-up. The implant survival rate was reported in two RCTs, which were from 89% to 98% and 99% to 100% for MDIs and SDIs, respectively. All RCTs had a low RoB. CONCLUSION: Mini dental implants represent a viable alternative to traditional standard-diameter implants when seeking optimal retention for mandibular overdentures.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Retenção de Dentadura , Revestimento de Dentadura , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Mandíbula/cirurgia , Prótese Total Inferior , Planejamento de Prótese Dentária
18.
J Periodontol ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38742564

RESUMO

BACKGROUND: Bone readiness for implant placement is typically evaluated by bone quality/density on 2-dimensional radiographs and cone beam computed tomography at an arbitrary time between 3 and 6 months after tooth extraction and alveolar ridge preservation (ARP). The aim of this study is to investigate if high-frequency ultrasound (US) can classify bone readiness in humans, using micro-CT as a reference standard to obtain bone mineral density (BMD) and bone volume fraction (BVTV) of healed sockets receiving ARP in humans. METHODS: A total of 27 bone cores were harvested during the implant surgery from 24 patients who received prior extraction with ARP. US images were taken immediately before the implant surgery at a site co-registered with the tissue biopsy collection location, made possible with a specially designed guide, and then classified into 3 tiers using B-mode image criteria (1) favorable, (2) questionable, and (3) unfavorable. Bone mineral density (hydroxyapatite) and BVTV were obtained from micro-CT as the gold standard. RESULTS: Hydroxyapatite and BVTV were evaluated within the projected US slice plane and thresholded to favorable (>2200 mg/cm3; >0.45 mm3/mm3), questionable (1500-2200 mg/cm3; 0.4-0.45 mm3/mm3), and unfavorable (<1500 mg/cm3; <0.4 mm3/mm3). The present US B-mode classification inversely scales with BMD. Regression analysis showed a significant relation between US classification and BMD as well as BVTV. T-test analysis demonstrated a significant correlation between US reader scores and the gold standard. When comparing Tier 1 with the combination of Tier 2 and 3, US achieved a significant group differentiation relative to mean BMD (p = 0.004, true positive 66.7%, false positive 0%, true negative 100%, false negative 33.3%, specificity 100%, sensitivity 66.7%, receiver operating characteristics area under the curve 0.86). Similar results were found between US-derived tiers and BVTV. CONCLUSION: Preliminary data suggest US could classify jawbone surface quality that correlates with BMD/BVTV and serve as the basis for future development of US-based socket healing evaluation after ARP.

19.
Medicina (Kaunas) ; 60(5)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38792903

RESUMO

(1) Background: Recent digital workflows are being developed for full-arch rehabilitations supported by implants with immediate function. The purpose of this case series is to describe a new digital workflow for the All-on-4 concept. (2) Methods: The patients were rehabilitated using the All-on-4 concept with a digital workflow including computerized tomography scanning, intra-oral scanning, and CAD-CAM production of the temporary prosthesis, with the 3D printing of stackable guides (base guide, implant guide, and prosthetic guide). The passive fit of the prostheses and the time to perform the rehabilitations were evaluated. (3) Results: The digital workflow allowed for predictable bone reduction, the insertion of implants with immediate function, and the connection of an implant-supported prosthesis with immediate loading. The time registered to perform the full-arch rehabilitations (implant insertion, abutment connection, prosthesis connection) was below 2 hours and 30 min. No passive fit issues were noted. (4) Conclusions: within the limitation of this case series, the digital workflow applied to the All-on-4 concept using stackable base-, implant-, and prosthetic guides constitutes a potential alternative with decreased time for the procedure without prejudice of the outcome.


Assuntos
Fluxo de Trabalho , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Desenho Assistido por Computador , Idoso , Prótese Dentária Fixada por Implante/métodos , Impressão Tridimensional , Tomografia Computadorizada por Raios X/métodos , Boca Edêntula/reabilitação
20.
J Pers Med ; 14(5)2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38793123

RESUMO

As an alternative to regenerative therapies, numerous authors have recently proposed bringing back subperiosteal implants. The aim of the study was to present our clinical experience with a subperiosteal jaw implant that needs minimal bone preparation and enables the rapid implantation of prosthetic teeth in edentulous, atrophic alveolar bone. The research included 36 complete or partial edentulous patients (61 subperiostal implants) over a period of 6 years. To create the patient-specific subperiostal implants design, DentalCAD 3.0 Galway software (exocad GmbH, Darmstadt, Germany) was used and fabricated with a Mysint 100 (Sisma S.p.A., Piovene Rocchette, Italy) by titanium alloy powder. The results showed that only 9 of the 36 cases were successful at 6-year follow-up, while 27 cases had complications, including exposure of the metal frame (early or delayed), mobility of the device prior to the first 4-6 months, and late mobility due to recurrent infections and progressive structure exposure; 1 case failed for reasons unrelated to the device. This study indicated that the prudent application of fully customized subperiosteal jaw implants is a dependable alternative for the dental rehabilitation of atrophic edentulous cases that necessitate bone grafts for traditional fixed dental implant solutions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA