Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
2.
Front Mol Biosci ; 11: 1345356, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38357630

RESUMO

As hormonal disorders are linked to several diseases, the accurate quantitation of steroid hormone levels in serum is crucial in order to provide patients with a reliable diagnosis. Mass spectrometry-based methods are regarded as having the highest level of specificity and sensitivity. However, immunoassays are more commonly used in routine diagnostics to measure steroid levels as they are more cost effective and straightforward to conduct. This study analyzes the external quality assessment results for the measurement of testosterone, progesterone and 17ß-estradiol in serum using immunoassays between early 2020 and May 2022. As reference measurement procedures are available for the three steroid hormones, the manufacturer-specific biases were normalized to the reference measurement values. The manufacturer-specific coefficients of variation were predominantly inconspicuous, below 20% for the three hormones when outliers are disregarded, however there were large differences between the various manufacturer collectives. For some collectives, the median bias to the respective reference measurement value was repeatedly greater than ±35%, which is the acceptance limit defined by the German Medical Association. In the case of testosterone and progesterone determination, some collectives tended to consistently over- or underestimate analyte concentrations compared to the reference measurement value, however, for 17ß-estradiol determination, both positive and negative biases were observed. This insufficient level of accuracy suggests that cross-reactivity continues to be a fundamental challenge when antibody detection is used to quantify steroids with a high structural similarity. Distinct improvements in standardization are required to provide accurate analysis and thus, reliable clinical interpretations. The increased accuracy of the AX immunoassay for testosterone measurement, as observed in the INSTAND EQAs between 2020 and 2022, could be the result of a recalibration of the assay and raises hope for further improvement of standardization of immunoassay-based steroid hormone analyses in the coming years.

3.
Front Immunol ; 14: 1129765, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36926342

RESUMO

Introduction: External Quality Assessment (EQA) schemes are designed to provide a snapshot of laboratory proficiency, identifying issues and providing feedback to improve laboratory performance and inter-laboratory agreement in testing. Currently there are no international EQA schemes for seasonal influenza serology testing. Here we present a feasibility study for conducting an EQA scheme for influenza serology methods. Methods: We invited participant laboratories from industry, contract research organizations (CROs), academia and public health institutions who regularly conduct hemagglutination inhibition (HAI) and microneutralization (MN) assays and have an interest in serology standardization. In total 16 laboratories returned data including 19 data sets for HAI assays and 9 data sets for MN assays. Results: Within run analysis demonstrated good laboratory performance for HAI, with intrinsically higher levels of intra-assay variation for MN assays. Between run analysis showed laboratory and strain specific issues, particularly with B strains for HAI, whilst MN testing was consistently good across labs and strains. Inter-laboratory variability was higher for MN assays than HAI, however both assays showed a significant reduction in inter-laboratory variation when a human sera pool is used as a standard for normalization. Discussion: This study has received positive feedback from participants, highlighting the benefit such an EQA scheme would have on improving laboratory performance, reducing inter laboratory variation and raising awareness of both harmonized protocol use and the benefit of biological standards for seasonal influenza serology testing.


Assuntos
Influenza Humana , Humanos , Hemaglutinação , Laboratórios , Estudos de Viabilidade , Estações do Ano
4.
Parasite ; 29: 45, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36200781

RESUMO

Accurate identification of insect species is an indispensable and challenging requirement for every entomologist, particularly if the species is involved in disease outbreaks. The European MediLabSecure project designed an identification (ID) exercise available to any willing participant with the aim of assessing and improving knowledge in mosquito taxonomy. The exercise was based on high-definition photomicrographs of mosquitoes (26 adult females and 12 larvae) collected from the western Palaearctic. Sixty-five responses from Europe, North Africa and the Middle East were usable. The study demonstrated that the responders were better at identifying females (82% correct responses) than larvae (63%). When the responders reported that they were sure of the accuracy of their ID, the success rate of ID increased (92% for females and 88% for larvae). The top three tools used for ID were MosKeyTool (72% of responders), the ID key following Becker et al. [2010. Mosquitoes and their control, 2nd edn. Berlin: Springer] (38%), and the CD-ROM of Schaffner et al. [2001. Les moustiques d'Europe: logiciel d'identification et d'enseignement - The mosquitoes of Europe: an identification and training programme. Montpellier: IRD; EID] (32%), while other tools were used by less than 10% of responders. Responders reporting the identification of mosquitoes using the MosKeyTool were significantly better (80% correct responses) than non-MosKeyTool users (69%). Most responders (63%) used more than one ID tool. The feedback from responders in this study was positive, with the exercise being perceived as halfway between educational training and a fun quiz. It raised the importance of further expanding training in mosquito ID for better preparedness of mosquito surveillance and control programmes.


Title: Évaluation de l'expertise en identification morphologique des espèces de moustiques (Diptera, Culicidae) à l'aide de photomicrographies. Abstract: L'identification précise des espèces d'insectes est une exigence indispensable et difficile pour tout entomologiste, en particulier si l'espèce est impliquée dans des épidémies. Le projet européen MediLabSecure a conçu un exercice d'identification (ID) accessible à tout participant volontaire dans le but d'évaluer et d'améliorer les connaissances en taxonomie des moustiques. L'exercice était basé sur des photomicrographies haute définition de moustiques (26 femelles adultes et 12 larves) prélevées dans le Paléarctique occidental. Soixante-cinq réponses d'Europe, d'Afrique du Nord et du Moyen-Orient ont été utilisables. L'étude a démontré que les répondants étaient meilleurs pour identifier les femelles (82 % de réponses correctes) que les larves (63 %). Lorsque les répondants ont déclaré être sûrs de l'exactitude de leur ID, le taux de réussite de l'identification était meilleur (92 % pour les femelles et 88 % pour les larves). Les trois principaux outils utilisés pour les ID étaient MosKeyTool (72 % des répondants), la clé d'identification du livre de Becker et al. (38%) et le CD-ROM de Schaffner et al. (32 %), tandis que d'autres outils étaient utilisés par moins de 10 % des répondants. Les répondants déclarant identifier des moustiques à l'aide de MosKeyTool étaient significativement meilleurs (80 % de réponses correctes) que les non-utilisateurs de MosKeyTool (69 %). La plupart des répondants (63 %) ont utilisé plus d'un outil d'identification. Les commentaires des répondants de cette étude ont été positifs, l'exercice étant perçu comme à mi-chemin entre une formation pédagogique et un quiz amusant. Il a souligné l'importance d'étendre la formation complémentaire à l'identification des moustiques pour une meilleure préparation des programmes de surveillance et de contrôle des moustiques.


Assuntos
Culicidae , África do Norte , Animais , Surtos de Doenças , Europa (Continente) , Feminino , Humanos , Larva , Mosquitos Vetores
5.
Diagnostics (Basel) ; 12(6)2022 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-35741293

RESUMO

For diagnosing SARS-CoV-2 infection and for monitoring its spread, the implementation of external quality assessment (EQA) schemes is mandatory to assess and ensure a standard quality according to national and international guidelines. Here, we present the results of the 2020, 2021, 2022 EQA schemes in Lombardy region for assessing the quality of the diagnostic laboratories involved in SARS-CoV-2 diagnosis. In the framework of the Quality Assurance Programs (QAPs), the routinely EQA schemes are managed by the regional reference centre for diagnostic laboratories quality (RRC-EQA) of the Lombardy region and are carried out by all the diagnostic laboratories. Three EQA programs were organized: (1) EQA of SARS-CoV-2 nucleic acid detection; (2) EQA of anti-SARS-CoV-2-antibody testing; (3) EQA of SARS-CoV-2 direct antigens detection. The percentage of concordance of 1938 molecular tests carried out within the SARS-CoV-2 nucleic acid detection EQA was 97.7%. The overall concordance of 1875 tests carried out within the anti-SARS-CoV-2 antibody EQA was 93.9% (79.6% for IgM). The overall concordance of 1495 tests carried out within the SARS-CoV-2 direct antigens detection EQA was 85% and it was negatively impacted by the results obtained by the analysis of weak positive samples. In conclusion, the EQA schemes for assessing the accuracy of SARS-CoV-2 diagnosis in the Lombardy region highlighted a suitable reproducibility and reliability of diagnostic assays, despite the heterogeneous landscape of SARS-CoV-2 tests and methods. Laboratory testing based on the detection of viral RNA in respiratory samples can be considered the gold standard for SARS-CoV-2 diagnosis.

6.
Clin Chem Lab Med ; 60(3): 361-369, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35041777

RESUMO

OBJECTIVES: Medical laboratories may, at their own discretion, exceed but not undercut regulatory quality requirements. Available economic resources, however, may drive or hinder eagerness to exceed minimum requirements. Depending on the respective scopes of regulatory and economic framework conditions, differing levels of quality efforts to safeguard laboratory performance can be anticipated. However, this has not yet been investigated. METHODS: Immunohaematology external quality assessment (EQA) results collected by 26 EQA providers from their participant laboratories in 73 countries from 2004 to 2019 were evaluated. Error rates were aggregated in groups according to the respective national regulatory and economic framework conditions, to whether or not expert advice was provided in case of incorrect results, and the frequency of EQA samples. RESULTS: These representative data indicate no association between national regulatory (mandatory participation in EQA, monitoring of performance of individual laboratories by authorities, financial consequences of incorrect results) and economic (level of national income, share of national health expenditure) conditions to the quality performance of medical laboratories in immunohaematology. However, EQA providers' support for laboratories in the event of incorrect results appear to be associated with lower error rates, but a high EQA sample frequency with higher error rates. CONCLUSIONS: Further research into the impact of introducing or changing services of EQA providers is needed to confirm the results found in this first of its kind study.


Assuntos
Hematologia , Laboratórios , Humanos , Garantia da Qualidade dos Cuidados de Saúde
7.
J Infect Public Health ; 15(2): 203-209, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35038668

RESUMO

BACKGROUND: Emerging infectious diseases pose an increasing threat to all nations around the world, including to developed countries. By definition, because they are rare or unknown, public health systems are not well prepared against these emerging diseases. To be fully prepared, countries must have implemented surveillance systems to monitor rare or unusual sanitary events. METHODS: The capacity of diagnostic laboratories is a key component of surveillance systems since they are in charge of identifying the pathogens responsible for outbreaks in a timely manner. The MediLabSecure project aims at implementing a comprehensive surveillance system for vector-borne diseases around the Mediterranean and Black Sea regions. From 2014 to 2018, the human-virology group of MediLabSecure notably supported the implementation of molecular diagnostic capacities for eight arboviruses and one coronavirus in 19 laboratories of its network through sharing of protocols and reagents, and technical training of the scientific staff of beneficiary laboratories. RESULTS: We report the results of External Quality Assessments for four of these viruses to assess the efficiency of the diagnostic for these threats emerging in the geographic area. The results for these EQA demonstrate the success of the project in the implementation of diagnostic technics for the identification of Dengue, Chikungunya, Zika, and West Niles viruses in laboratories that did not have the capacity before. However, results also show that some work is still to be done to strengthen the newly acquired capacity. CONCLUSION: The MediLabSecure project deployed an effort to build an efficient capacity in identifying and survey the emergence of arboviruses in the Mediterranean area. Diagnostic technics were successfully implemented in many of the laboratories of the network, but the effort must be maintained over time to strengthen these capacities.


Assuntos
Infecções por Arbovirus , Arbovírus , Febre de Chikungunya , Infecção por Zika virus , Zika virus , Infecções por Arbovirus/diagnóstico , Infecções por Arbovirus/epidemiologia , Humanos
8.
Clin Chem Lab Med ; 60(1): 66-73, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-34670030

RESUMO

OBJECTIVES: Serum indices included in clinical chemistry instruments are widely used by laboratories to assess the quality of samples. Instruments that report quantitative results allow an evaluation of their diagnostic performance in a similar way to other biochemical tests. The Spanish Society of Laboratory Medicine (SEQC-ML) launched a monthly External Quality program of serum indices in 2018 using three lyophilized materials of simultaneous annual distribution. We present the results of the first three years of the program. METHODS: The use of four different quality control materials with different concentrations in three alternate months allows an annual evaluation of the participant's accuracy. Assigned values are established by consensus among homogeneous groups, considering necessary at least 10 participants for a comparison at instrument level. The average percentage difference results per instrument allow the assessment of bias among groups. RESULTS: The imprecision of the three indices ranges between 3 and 9%, with no major differences among instruments. Significant differences were observed in all indices among instruments with more than 10 participants (Roche Cobas, Abbott Architect, Abbott Alinity and Siemens Advia). The 90th percentile of the distribution of percentage differences was used as the analytical performance specification (APS). An improvement in performance was observed in the first three years of the program, probably due to the learning curve effect. In 2020, APS of 7.8, 12.2 and 9.7% were proposed for hemolytic, icteric and lipemic indices, respectively. CONCLUSIONS: Serum indices have a great impact on the quality and the reliability of laboratory test results. Participation in proficiency testing programs for serum indices is helpful to encourage harmonization among providers and laboratories.


Assuntos
Laboratórios , Ensaio de Proficiência Laboratorial , Humanos , Controle de Qualidade , Reprodutibilidade dos Testes , Soro
9.
Br J Haematol ; 194(1): 53-60, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34114218

RESUMO

Measurement of BCR activator of RhoGEF and GTPase -ABL proto-oncogene 1, non-receptor tyrosine kinase (BCR-ABL1) mRNA levels by reverse transcription quantitative polymerase chain reaction (RTqPCR) has been critical to treatment protocols and clinical trials in chronic myeloid leukaemia; however, interlaboratory variation remains a significant issue. Reverse transcriptase droplet digital PCR (RTddPCR) has shown potential to improve testing but a large-scale interlaboratory study is required to definitively establish this. In the present study, 10 BCR-ABL1-positive samples with levels ranging from molecular response (MR)1·0 -MR5·0 were tested by 23 laboratories using RTddPCR with the QXDX BCR-ABL %IS kit. A subset of participants tested the samples using RTqPCR. All 23 participants using RTddPCR detected BCR-ABL1 in all samples to MR4·0 . Detection rates for deep-response samples were 95·7% at MR4·5 , 78·3% at MR4·7 and 87·0% at MR5·0 . Interlaboratory coefficient of variation was indirectly proportional to BCR-ABL1 level ranging from 29·3% to 69·0%. Linearity ranged from 0·9330 to 1·000 (average 0·9936). When results were compared for the 11 participants who performed both RTddPCR and RTqPCR, RTddPCR showed a similar limit of detection to RTqPCR with reduced interlaboratory variation and better assay linearity. The ability to detect deep responses with RTddPCR, matched with an improved linearity and reduced interlaboratory variation will allow improved patient management, and is of particular importance for future clinical trials focussed on achieving and maintaining treatment-free remission.


Assuntos
Proteínas de Fusão bcr-abl/sangue , Ensaio de Proficiência Laboratorial , Leucemia Mielogênica Crônica BCR-ABL Positiva/sangue , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Ásia , Biomarcadores Tumorais/sangue , Europa (Continente) , Células HL-60/química , Humanos , Células K562/química , Laboratórios Clínicos , Modelos Lineares , América do Norte , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes
10.
Pathogens ; 9(12)2020 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-33322276

RESUMO

The increasing incidence of West Nile virus (WNV) in the Euro-Mediterranean area warrants the implementation of effective surveillance programs in animals. A crucial step in the fight against the disease is the evaluation of the capacity of the veterinary labs to accurately detect the infection in animal populations. In this context, the animal virology network of the MediLabSecure project organized an external quality assessment (EQA) to evaluate the WNV molecular and serological diagnostic capacities of beneficiary veterinary labs. Laboratories from 17 Mediterranean and Black Sea countries participated. The results of the triplex real time RT-PCR for simultaneous detection and differentiation of WNV lineage 1 (L1), lineage 2 (L2) and Usutu virus (USUV) were highly satisfactory, especially for L1 and L2, with detection rates of 97.9% and 100%, respectively. For USUV, 75% of the labs reported correct results. More limitations were observed for the generic detection of flaviviruses using conventional reverse-transcription polymerase chain reaction (RT-PCR), since only 46.1% reported correct results in the whole panel. As regards the serological panel, the results were excellent for the generic detection of WNV antibodies. More variability was observed for the specific detection of IgM antibodies with a higher percentage of incorrect results mainly in samples with low titers. This EQA provides a good overview of the WNV (and USUV) diagnostic performance of the involved veterinary labs and demonstrates that the implemented training program was successful in upgrading their diagnostic capacities.

11.
Clin Chem Lab Med ; 59(2): 307-313, 2020 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-32772000

RESUMO

Objectives: External quality assessment schemes (EQAS) are being established worldwide to support the faecal immunochemical test (FIT) for haemoglobin (Hb). FIT is widely used as a screening test for colorectal cancer and increasingly in assessment of patients presenting with symptoms. EQA for FIT is provided in several matrices, each unique to the individual scheme. These include Hb suspended in a faecal-like matrix, lyophilised samples and liquid samples. The aim of this study was to evaluate commercially available EQAS and assess their suitability for use. Methods: Ten EQAS provided material for the study. EQA samples were analysed on four quantitative FIT systems. 15 faecal-like matrix samples were loaded per concentration per FIT system. Reconstituted lyophilised samples were examined five times on three separate occasions and liquid samples were examined 10 times per concentration per FIT system. The coefficient of variation (CV) was calculated per concentration of EQA for each FIT system. Results: Results from faecal-like matrix schemes had a higher median CV (12.4-19.0%) when compared to those from schemes providing liquid matrices (0.8-2.3%). The spread of CV values was also higher for results from faecal-like matrix schemes with an interquartile range (IQR) 4.4-24.0% vs. liquid IQR range of 0.3-2.5%. Conclusions: Hb results from faecal-like matrices, whilst more aligned to a patient or participant sample, are prone to pre-examination variation so do not assess the analytical accuracy of a FIT system. Liquid matrices are not prone to pre-examination variation and are better able to assess the accuracy of a FIT system.


Assuntos
Fezes/química , Hemoglobinas/análise , Sangue Oculto , Garantia da Qualidade dos Cuidados de Saúde/métodos , Técnicas e Procedimentos Diagnósticos , Humanos , Imunoensaio , Laboratórios/normas , Padrões de Referência
12.
Euro Surveill ; 25(27)2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32672149

RESUMO

Laboratory preparedness with quality-assured diagnostic assays is essential for controlling the current coronavirus disease (COVID-19) outbreak. We conducted an external quality assessment study with inactivated severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) samples to support clinical laboratories with a proficiency testing option for molecular assays. To analyse SARS-CoV-2 testing performance, we used an online questionnaire developed for the European Union project RECOVER to assess molecular testing capacities in clinical diagnostic laboratories.


Assuntos
Técnicas de Laboratório Clínico/métodos , Técnicas de Laboratório Clínico/normas , Infecções por Coronavirus/diagnóstico , Coronavirus/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Pandemias , Pneumonia Viral/diagnóstico , Betacoronavirus , COVID-19 , Teste para COVID-19 , Vacinas contra COVID-19 , Serviços de Laboratório Clínico , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/virologia , Surtos de Doenças , Europa (Continente) , Humanos , Pandemias/prevenção & controle , Pneumonia Viral/epidemiologia , Pneumonia Viral/virologia , Reação em Cadeia da Polimerase em Tempo Real/normas , Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , SARS-CoV-2 , Sensibilidade e Especificidade , Inquéritos e Questionários
14.
Clin Chem Lab Med ; 56(12): 2039-2046, 2018 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-30016273

RESUMO

Background ISO 9001 and ISO 15189 have been established as continuative models for quality systems beyond national laws, mandatory standards and guidelines of expert associations regarding analytical and organisational performance of medical laboratories and transfusion services. Although widely used, their impact on laboratory performance has not been investigated. Methods We retrospectively analysed the results of 167 laboratories in 59 distributions of the Austrian red cell immunohaematology external quality assessment (EQA) scheme in the years 1999-2017. The performance for each parameter and trends of individual participants were compared with respect to certification or accreditation status of participants' quality systems and to laboratory type. Results Considering more than 52,000 EQA results, the absence or presence of a laboratory quality management system showed different error rates. Laboratories with ISO 9001 or ISO 15189 certification/accreditation had 0.7% incorrect results, while this rate was doubled without such quality systems (1.4%, p=0.0002). Statistically significant error reductions were seen upon ISO 9001/ISO 15189 implementation (1.3% before vs. 0.7% after; p=0.0468). Transfusion services had fewer errors (0.9%) compared to hospital and independent laboratories (both 1.2%). Conclusions Implementation and maintenance of quality systems according to ISO 9001 or ISO 15189 as well as laboratory specialisation result in better analytical performance as can be seen in immunohaematology EQA results. The conclusion is that these results apply to other laboratory tests and perhaps to other areas of health care.


Assuntos
Alergia e Imunologia/normas , Hematologia/normas , Laboratórios/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Áustria , Humanos , Controle de Qualidade , Estudos Retrospectivos
15.
Clin Chem Lab Med ; 55(12): 1936-1942, 2017 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-28301316

RESUMO

BACKGROUND: A study performed in 2007 comparing the evaluation procedures used in European external quality assessment schemes (EQAS) for hemoglobin and leukocyte concentrations showed that acceptance criteria vary widely. For this reason, the Hematology working group from the European Organisation for External Quality Assurance Providers in Laboratory Medicine (EQALM) decided to perform a statistical study with the aim of establishing appropriate acceptance limits (AL) allowing harmonization between the evaluation procedures of European EQAS organizers. METHODS: Eight EQAS organizers from seven European countries provided their hematology survey results from 2010 to 2012 for red blood cells (RBC), hemoglobin, hematocrit, mean corpuscular volume (MCV), white blood cells (WBC), platelets and reticulocytes. More than 440,000 data were collected. The relation between the absolute value of the relative differences between reported EQA results and their corresponding assigned value (U-scores) was modeled by means of an adaptation of Thompson's "characteristic function". Quantile regression was used to investigate the percentiles of the U-scores for each target concentration range. For deriving AL, focus was mainly on the upper percentiles (90th, 95th and 99th). RESULTS: For RBC, hemoglobin, hematocrit and MCV, no relation was found between the U-scores and the target concentrations for any of the percentiles. For WBC, platelets and reticulocytes, a relation with the target concentrations was found and concentration-dependent ALs were determined. CONCLUSIONS: The approach enabled to determine state of the art-based ALs, that were concentration-dependent when necessary and usable by various EQA providers. It could also easily be applied to other domains.


Assuntos
Hematologia/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Índices de Eritrócitos , Eritrócitos , Europa (Continente) , Hematócrito , Hemoglobinas/análise , Humanos , Leucócitos
16.
Immunobiology ; 221(11): 1247-58, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27475991

RESUMO

In recent years, complement analysis of body fluids and biopsies, going far beyond C3 and C4, has significantly enhanced our understanding of the disease process. Such expanded complement analysis allows for a more precise differential diagnosis and for critical monitoring of complement-targeted therapy. These changes are a result of the growing understanding of the involvement of complement in a diverse set of disorders. To appreciate the importance of proper complement analysis, it is important to understand the role it plays in disease. Historically, it was the absence of complement as manifested in severe infection that was noted. Since then complement has been connected to a variety of inflammatory disorders, such as autoimmune diseases and hereditary angioedema. While the role of complement in the rejection of renal grafts has been known longer, the significant impact of complement. In certain nephropathies has now led to the reclassification of some rare kidney diseases and an increased role for complement analysis in diagnosis. Even more unexpected is that complement has also been implicated in neural, ophtalmological and dermatological disorders. With this level of involvement in some varied and impactful health issues proper complement testing is clearly important; however, analysis of the complement system varies widely among laboratories. Except for a few proteins, such as C3 and C4, there are neither well-characterized standard preparations nor calibrated assays available. This is especially true for the inter-laboratory variation of tests which assess classical, alternative, or lectin pathway function. In addition, there is a need for the standardization of the measurement of complement activation products that are so critical in determining whether clinically relevant complement activation has occurred in vivo. Finally, autoantibodies to complement proteins (e.g. anti-C1q), C3 and C4 convertases (C3 and C4 nephritic factor) or to regulatory proteins (e.g. anti-C1inhibitor, anti-factor H) are important in defining autoimmune processes and diseases based on complement dysregulation. To improve the quality of complement laboratory analysis a standardization commmittee of the International Complement Society (ICS) and the International Union of Immunological Societies (IUIS) was formed to provide guidelines for modern complement analysis and standards for the development of international testing programs.


Assuntos
Proteínas do Sistema Complemento/imunologia , Proteínas do Sistema Complemento/metabolismo , Suscetibilidade a Doenças , Testes Imunológicos , Algoritmos , Tomada de Decisão Clínica , Humanos , Testes Imunológicos/métodos , Testes Imunológicos/normas , Garantia da Qualidade dos Cuidados de Saúde , Controle de Qualidade
17.
Anal Biochem ; 479: 60-2, 2015 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-25817220

RESUMO

In this note, we present an ad hoc procedure that combines qualitative (visual evaluation) and quantitative (ImageJ software) evaluations of Pulsed-Field Gel Electrophoresis (PFGE) images to assess the genomic DNA (gDNA) integrity of analyzed samples. This procedure could be suitable for the analysis of a large number of images by taking into consideration both the expertise of researchers and the objectiveness of the software. We applied this procedure on the first SPIDIA DNA External Quality Assessment (EQA) samples. Results show that the classification obtained by this ad hoc procedure allows a more accurate evaluation of gDNA integrity with respect to a single approach.


Assuntos
DNA/química , Eletroforese em Gel de Campo Pulsado/métodos , Processamento de Imagem Assistida por Computador/métodos , Software , DNA/sangue , DNA/genética , Genômica/métodos , Humanos
18.
Ger Med Sci ; 3: Doc02, 2005 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-19675719

RESUMO

This review shows the current analytical quality for the following analytes used as tumour markers in the external quality assessment (EQA)-programmes of Instand e.V., a national EQA-organiser in Germany: Corticotropin (ACTH), growth hormone (GH, hGH), prolactin (PRL), chorionic gonadotropin (CG, hCG), calcitonin (CT, hCT), thyroglobulin (Tg), carcinoembryonic antigen (CEA), CA-Antigens 125, 72-4, 15-3 and 19-9, alpha foetoprotein (AFP) and prostate-specific antigen (PSA). The results from the participants show a large variation in the precision of the methods used as well as in the comparability of results between methods for the same analyte. In general, the hormones used as tumour markers show better performance than the "CA-markers", which are often inadequately standardised and defined. In the case of one CA-marker (CA 72-4/TAG 72-4), the differences between the lowest kit median concentration and highest kit median concentration for one sample pair were 440% and 580%. The corresponding figures for ACTH were 123% and 156% and for CEA 180% and 184%. The classical tumour markers such as carcinoembryonic antigen (CEA) and alpha foetoprotein (AFP) performed markedly better than the CA-markers and PSA with regards to both inter- and intra-method comparability. The inter-laboratory precision for a given kit and marker was acceptable in many cases. The results show that only results from the same kit/method for each tumour marker can be used for cumulative or time-dependent comparison of results - for example pre-operative and post-operative follow up. In the case of prostate specific antigen (PSA), the kits used for free and total PSA must come from the same producer, if the generally accepted ratios are to have any diagnostic value. The need for kit- and laboratory-specific reference ranges and cut-off values for setting diagnostic specificity and sensitivity is highlighted from the EQA-results. The situation for inter-method comparability for the CA-Markers has not improved over the past decade. With the exception of calcitonin for detecting medullary thyroid carcinoma, chorionic gonadotropin in germ-cell tumours in men and thyroglobulin after total thyroidectomy, none of the remaining analytes appear to be suitable for screening purposes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA