Anal Biochem ; 693: 115593, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38885872

RESUMO

MicroRNA (miRNA) is a pivotal biomarker in the diagnosis of various cancers, including bladder cancer (BCa). Despite their significance, the low abundance of miRNA presents a substantial challenge for sensitive and reliable detection. We introduce an innovative, highly sensitive assay for miRNA expression quantification that is both enzyme-free and portable. This method leverages the synergy of target recycling and entropy-driven assembly (EDA) for enhanced sensitivity and specificity. The proposed method possesses several advantages, including i) dual signal amplification through target recycling and EDA, which significantly boosts sensitivity with a lower limit of detection of 2.54 fM; ii) elimination of enzyme requirements, resulting in a cost-effective and stable signal amplification process; and iii) utilization of a personal glucose meter (PGM) for signal recording, rendering the method portable and adaptable to diverse settings. In summary, this PGM-based approach holds promising potential for clinical molecular diagnostics, offering a practical and efficient solution for miRNA analysis in cancer detection.


Assuntos
Entropia , MicroRNAs , MicroRNAs/análise , MicroRNAs/genética , Humanos , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias da Bexiga Urinária/genética , Limite de Detecção , Técnicas Biossensoriais/métodos , Biomarcadores Tumorais/genética , Biomarcadores Tumorais/análise
2.
Ter Arkh ; 96(3): 312-314, 2024 Apr 16.
Artigo em Russo | MEDLINE | ID: mdl-38713050

RESUMO

In the article "Point-of-care blood glucose testing: post-market performance assessment of the Accu-Chek Inform II hospital-use glucose meter," published in the Terapevticheskii Arkhiv journal, Vol. 95, No.12, 2023 (DOI: 10.26442/00403660.2023.12.202522), errors were made: the term "measurements at the place of treatment" was changed, as well as the section "Conflict of interest." At the request of the authors' team, errors in the conflict of interest and the wording of the term have been corrected, and the section "Information about the authors" has been updated. The publisher replaced the original version of the published article with the corrected one; the information on the website was also corrected. Correct text of the section "Conflict of interest": Conflict of interest. All authors are not employees or consultants of Roche Diagnostics and have not received any compensation from Roche Diagnostics. Correct wording of the term in Russian: "измерения по месту лечения". Changes were made to the title of the article in Russian: "Измерения глюкозы по месту лечения: пострегистрационное испытание госпитального глюкометра Акку-Чек Информ II", the text of the abstract, keywords, citation, in the text of the article, and abbreviations. Information of the place of work has been updated: Center for Laboratory Diagnostics of the Russian Children Clinical Hospital, a Branch of the Pirogov Russian National Research Medical University. The publisher apologizes to readers and authors for the errors and is confident that the correction of errors will ensure the correct perception and interpretation of the results of the study described in the text.


Assuntos
Glicemia , Humanos , Glicemia/análise , Sistemas Automatizados de Assistência Junto ao Leito , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Testes Imediatos , Vigilância de Produtos Comercializados/métodos , Federação Russa
3.
Biosens Bioelectron ; 253: 116141, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38428072

RESUMO

Rapid and precise detection of hydrogen peroxide (H2O2) holds great significance since it is linked to numerous physiological and inorganic catalytic processes. We herein developed a label-free and washing-free strategy to detect H2O2 by employing a hand-held personal glucose meter (PGM) as a signal readout device. By focusing on the fact that the reduced redox mediator ([Fe(CN)6]4-) itself is responsible for the final PGM signal, we developed a new PGM-based strategy to detect H2O2 by utilizing the target H2O2-mediated oxidation of [Fe(CN)6]4- to [Fe(CN)6]3- in the presence of horseradish peroxidase (HRP) and monitoring the reduced PGM signal in response to the target amount. Based on this straightforward and facile design principle, H2O2 was successfully determined down to 3.63 µM with high specificity against various non-target molecules. We further demonstrated that this strategy could be expanded to identify another model target choline by detecting H2O2 produced through its oxidation promoted by choline oxidase. Moreover, we verified its practical applicability by reliably determining extracellular H2O2 released from the breast cancer cell line, MDA-MB-231. This work could evolve into versatile PGM-based platform technology to identify various non-glucose target molecules by employing their corresponding oxidase enzymes, greatly advancing the portable biosensing technologies.


Assuntos
Técnicas Biossensoriais , Peróxido de Hidrogênio , Catálise , Colina , Glucose
4.
Heliyon ; 10(5): e27387, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38486754

RESUMO

Background: In response to the rise of intelligent products and the increasing prevalence of urban "empty nesters," we have developed a product specifically tailored for elderly diabetic patients. This product fulfils functional requirements and addresses stylistic preferences, contributing to the age-friendly evolution of home intelligent medical devices, particularly in intelligent blood glucose monitoring. Methods: Our approach commenced with a comprehensive user experience analysis to ascertain the needs of elderly users regarding home blood glucose meters. This involved constructing a hierarchy of user demands, followed by analysing and prioritising these needs. Utilizing Quality Function Deployment (QFD), we aligned user requirements with design specifications, identifying specific product functionalities and service design elements. Further, we employed Kansei Engineering (KE) to select sample designs that resonate with the concept of sensual imagery, leading to the derivation of specific modelling intentions. Combining these design elements, we proposed product design strategies and conducted practical case studies. The effectiveness of these designs was then assessed through fuzzy evaluation methods, allowing for user feedback. Results: Employing the Analytic Hierarchy Process for goal analysis, along with Quality Function Deployment theory and Kansei Engineering, we developed a home intelligent blood glucose meter catered to the elderly. This device not only meets its users' physiological and psychological needs but also provides an operationally convenient, health-conscious, and aesthetically pleasing experience. Conclusions: This methodology enhances the age-appropriate design of home-based smart glucose monitors for the elderly, offering innovative insights and optimization strategies for designing elderly-centric smart medical products.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38401042

RESUMO

In the field of neonatal infections nursing, methicillin-resistant Staphylococcus aureus (MRSA) is a major bacterial pathogen. Here, we present a portable biosensor for MRSA detection that is both highly sensitive and portable, owing to its implementation on the personal glucose meter (PGM) platform. The H probe was fixed on the magnetic bead for mecA gene analysis. A blunt 3' terminus appeared in the MBs-H probe when the mecA gene was present. Exonuclease-III (Exo-III) recognized the blunt terminus and cleaved it, freeing the mecA gene and so facilitating target recycling. In the meantime, the remaining H probe-initiated hybridization chain reaction (HCR) led to the desired signal amplification. Portable quantitative detection of mecA gene is possible because PGM can read the quantity of invertase tagged on HCR product. After optimizing several experimental parameters, such as the concentration of Exo-III and incubation time, the constructed sensor is extremely sensitive, with a detection limit of 2 CFU/mL. The results from this sensitive PGM-based sensor are in agreement with those obtained from plate counting methods, suggesting that it can be used to accurately assess the MRSA content in artificial clinical samples. In addition, the PGM sensor can significantly cut down on time spent compared to plate counting techniques. The manufactured sensor provides a promising option for accurate identification of pathogenic bacteria.

6.
Biosens Bioelectron ; 250: 116019, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38278122

RESUMO

We herein developed a label-free and washing-free method to detect biological thiols (biothiols) on a personal glucose meter (PGM) utilizing the intrinsic glucose oxidase (GOx)-mimicking activity of gold nanoparticles (AuNPs). By focusing on the fact that this activity could be diminished by target biothiols through their binding onto the AuNP surface, we correlated the concentration of biothiols with that of glucose readily measurable on a PGM and successfully determined cysteine (Cys), homocysteine (Hcy), and glutathione (GSH) down to 0.116, 0.059, and 0.133 µM, respectively, with high specificity against non-target biomolecules. We further demonstrated its practical applicability by reliably detecting target biothiol in heterogeneous human serum. Due to the meritorious features of PGM such as simplicity, portability, and cost-effectiveness, we believe that this work could serve as a powerful platform for biothiol detection in point-of-care settings.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Humanos , Compostos de Sulfidrila/química , Ouro/química , Glucose Oxidase , Nanopartículas Metálicas/química , Técnicas Biossensoriais/métodos , Cisteína/química , Glutationa/química , Homocisteína
7.
J Diabetes Sci Technol ; 18(3): 598-607, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38189290

RESUMO

BACKGROUND: Safe and effective self-management of glucose levels requires immediate access to accurate data. We assessed the point accuracy of the Dexcom G7 Continuous Glucose Monitoring System (Dexcom, Inc., San Diego, CA, USA) and FreeStyle Libre 3 (Abbott Diabetes Care, Alameda, CA, USA) sensors in a head-to-head comparison. METHOD: Multicenter, single-arm, prospective, nonsignificant risk evaluation enrolled adults (≥ 18 years) with diagnosed type 1 diabetes (T1D) or type 2 diabetes (T2D). Accuracy was assessed by comparing sensor data to laboratory reference values Yellow Springs Instrument [YSI] and capillary blood glucose values. Outcome measures were differences in mean absolute relative difference (MARD), number and percentage of matched glucose pairs within ±20 mg/dL/±20 of reference values within glucose ranges: < 54, 54 to 69, 70 to 180, 181 to 250, > 250 mg/dL, and combined. RESULTS: Data from 55 adults were included in the analysis. Analysis showed significantly lower MARD with the FreeStyle Libre 3 sensor vs the Dexcom G7 sensor (8.9% vs 13.6%, respectively, P < .0001) with a higher percentage of glucose values within ±20 mg/dL/±20 of reference (91.4% vs 78.6%). The MARD values for both continuous glucose monitoring (CGM) sensors were similar during the first 12 hours; however, the FreeStyle Libre 3 MARD was notably lower than the Dexcom G7 MARD during the next 12 hours (10.0% vs 15.1%, respectively, P < .0001) and throughout the study period. CONCLUSIONS: The FreeStyle Libre 3 sensor was more accurate than the Dexcom G7 sensor in all metrics evaluated throughout the study period. This is the first head-to-head study to our knowledge that compares the flagship products currently in widespread use of the two largest CGM manufacturers.


Assuntos
Monitoramento Contínuo da Glicose , Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glicemia/análise , Monitoramento Contínuo da Glicose/instrumentação , Monitoramento Contínuo da Glicose/normas , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/diagnóstico , Estudos Prospectivos , Reprodutibilidade dos Testes
8.
J Hazard Mater ; 465: 133424, 2024 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-38185088

RESUMO

Heavy metal pollution poses a major threat to human health, and developing a user-deliverable heavy metal detection strategy remains a major challenge. In this work, two-mode Hg2+ sensing platforms based on the tunable cobalt metal-organic framework (Co-MOF) active site strategy are constructed, including a colorimetric, and an electrochemical assay using a personal glucose meter (PGM) as the terminal device. Specifically, thymine (T), a single, adaptable nucleotide, is chosen to replace typical T-rich DNA aptamers. The catalytic sites of Co-MOF are tuned competitively by the specific binding of T-Hg2+-T, and different signal output platforms are developed based on the different enzyme-like activities of Co-MOF. DFT calculations are utilized to analyze the interaction mechanism between T and Co-MOF with defect structure. Notably, the two-mode sensing platforms exhibit outstanding detection performance, with LOD values as low as 0.5 nM (colorimetric) and 3.69 nM (PGM), respectively, superior to recently reported nanozyme-based Hg2+ sensors. In real samples of tap water and lake water, this approach demonstrates an effective recovery rate and outstanding selectivity. Surprisingly, the method is potentially versatile and, by exchanging out T-Hg2+-T, can also detect Ag+. This simple, portable, and user-friendly Hg2+ detection approach shows plenty of promise for application in the future.


Assuntos
Mercúrio , Estruturas Metalorgânicas , Humanos , Estruturas Metalorgânicas/química , Domínio Catalítico , Cobalto/química , Água/química , Mercúrio/química , Colorimetria
9.
Foods ; 12(21)2023 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-37959066

RESUMO

Food safety has emerged as a significant concern for global public health and sustainable development. The development of analytical tools capable of rapidly, conveniently, and sensitively detecting food safety hazards is imperative. Over the past few decades, personal glucose meters (PGMs), characterized by their rapid response, low cost, and high degree of commercialization, have served as portable signal output devices extensively utilized in the construction of biosensors. This paper provides a comprehensive overview of the mechanism underlying the construction of PGM-based biosensors, which consists of three fundamental components: recognition, signal transduction, and signal output. It also detailedly enumerates available recognition and signal transduction elements, and their modes of integration. Then, a multitude of instances is examined to present the latest advancements in the application of PGMs in food safety detection, including targets such as pathogenic bacteria, mycotoxins, agricultural and veterinary drug residues, heavy metal ions, and illegal additives. Finally, the challenges and prospects of PGM-based biosensors are highlighted, aiming to offer valuable references for the iterative refinement of detection techniques and provide a comprehensive framework and inspiration for further investigations.

10.
J Diabetes Sci Technol ; : 19322968231201862, 2023 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-37786261

RESUMO

New European medical device regulations require the performance of postmarketing surveillance evaluations for blood glucose meters (BGMs). We conducted an ISO15197:2015-conform system performance evaluation with the approved glucose dehydrogenase (GDH)-based Wellion NEWTON BGM. One hundred subjects were enrolled into the study (44 female, 56 male, 43 healthy subjects, 23 type 1 diabetes, 34 type 2 diabetes, age: 53.7 ± 15.8 years). In addition, manipulated heparinized whole blood was used for a laboratory interference test with ten selected substances (interference definition: substance-induced bias > 10%). The mean absolute relative difference (MARD) was 4.7%, and 100% of the values were in zones A (99.7%) and B (0.3%), respectively, of the consensus error grid. Interference was observed with xylose only, which is a known interfering substance for GDH-based BGMs.

11.
J Microbiol Biotechnol ; 33(12): 1692-1697, 2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-37734933

RESUMO

Staphylococcus aureus integrated with mecA gene, which codes for penicillin-binding protein 2a, is resistant to all penicillins and other beta-lactam antibiotics, resulting in poor treatment expectations in skin and soft tissue infections. The development of a simple, sensitive and portable biosensor for mecA gene analysis in S. aureus is urgently needed. Herein, we propose a dual-toehold-probe (sensing probe)-mediated exonuclease-III (Exo-III)-assisted signal recycling for portable detection of the mecA gene in S. aureus. When the target mecA gene is present, it hybridizes with the sensing probe, initiating Exo III-assisted dual signal recycles, which in turn release numerous "3" sequences. The released "3" sequences initiate catalytic hairpin amplification, resulting in the fixation of a sucrase-labeled H2 probe on the surface of magnetic beads (MBs). After magnet-based enrichment of an MB-H1-H2-sucrase complex and removal of a liquid supernatant containing free sucrase, the complex is then used to catalyze sucrose to glucose, which can be quantitatively detected by a personal glucose meter. With a limit of detection of 4.36 fM for mecA gene, the developed strategy exhibits high sensitivity. In addition, good selectivity and anti-interference capability were also attained with this method, making it promising for antibiotic tolerance analysis at the point-of-care.


Assuntos
Técnicas Biossensoriais , Infecções dos Tecidos Moles , Humanos , Staphylococcus aureus/genética , Glucose , Sacarase , Exonucleases , Técnicas Biossensoriais/métodos , Limite de Detecção
12.
Sens Actuators B Chem ; 3902023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37303825

RESUMO

Alpha-fetoprotein (AFP) is an important protein biomarker of liver cancer, as its serum levels are highly correlated with the progression of disease. Conventional immunoassays for AFP detection rely on enzyme-linked immunosorbent assay analyses with expensive and bulky equipment. Here, we developed a simple, affordable, and portable CRISPR-powered personal glucose meter biosensing platform for quantitative detection of the AFP biomarker in serum samples. The biosensor takes advantage of the excellent affinity of aptamer to AFP and the collateral cleavage activity of CRISPR-Cas12a, enabling sensitive and specific CRISPR-powered protein biomarker detection. To enable point-of-care testing, we coupled invertase-catalyzed glucose production with the glucose biosensing technology to quantify AFP. Using the developed biosensing platform, we quantitatively detected AFP biomarker in spiked human serum samples with a detection sensitivity of down to 10 ng/mL. Further, we successfully applied the biosensor to detect AFP in clinical serum samples from patients with liver cancer, achieving comparable performance to the conventional assay. Therefore, this novel CRISPR-powered personal glucose meter biosensor provides a simple yet powerful alternative for detecting AFP and potentially other tumor biomarkers at the point of care.

13.
Diabetes Ther ; 14(6): 1023-1035, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37138183

RESUMO

INTRODUCTION: The OneTouch Verio Reflect® (OTVR) Blood Glucose Meter features a color range indicator and provides on-meter guidance, insights, and encouragement. Diabetes management is enhanced by the OneTouch Reveal® (OTR) Mobile App. We sought to provide real-world evidence (RWE) that combining devices improves glycemia. METHODS: Anonymized glucose and app analytics from more than 55,000 people with diabetes (PWDs) were extracted from a server. Data from their first 14 days using OTVR Meter and OTR App was compared with 14 days prior to 90- and 180-day timepoints using paired within-subject differences. RESULTS: In people with type 1 (PwT1D) or type 2 diabetes (PwT2D), readings in-range (RIR 70-180 mg/dL) improved by 7.8 percentage points (57.9-65.7%) and 12.0 percentage points (72.8-84.8%), respectively, over 180 days and hyperglycemia (> 180 mg/dL) was reduced by - 8.4 percentage points (37.9-29.5%) and - 12.2 percentage points (26.2-14.1%). RIR improved by > 10 percentage points in 38% of PwT1D and 39% of PwT2D. PwT1D spending > 2 to 4 sessions or > 10 to 20 min per week on the app improved RIR by 7.0 and 8.2 percentage points, respectively. PwT2D spending > 2 to 4 sessions or > 10 to 20 min per week on the app improved RIR by 12.6 and 12.1 percentage points, respectively. In PwT1D or T2D, mean blood glucose reduced by - 14.3 and - 19.8 mg/dL, respectively, from baseline to 180 days, with no clinically meaningful changes in percentage of hypoglycemic readings (< 70 mg/dL). PwT1D 65 years and older performed the most app sessions (10 per week) and improved RIR by 7.9 percentage points. PwT2D 65 years and older spent more time on the app (45 min per week) than PwT2D of any other age and improved RIR by 7.6 percentage points. All glycemic changes were statistically significant (p < 0.0005). CONCLUSION: Real-world data from more than 55,000 PWDs demonstrates sustained improvements in readings in-range in PWDs using the OneTouch Verio Reflect Blood Glucose Meter and OneTouch Reveal App.

14.
Diabetes Ther ; 14(6): 989-1004, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37103775

RESUMO

INTRODUCTION: The aim of this study was to evaluate the stability and accuracy of glucose measurements determined using the metabolic heat conformation (MHC)-based non-invasive glucometer in a multicentre, self-controlled clinical trial. This device is the first to obtain a medical device registration certificate awarded by the National Medical Products Administration of China (NMPA). METHODS: The multicentre clinical study was conducted at three sites and enrolled 200 subjects whose glucose was measured with a non-invasive glucometer (the Contour Plus blood glucose monitoring system) and by venous plasma glucose (VPG) measurements, in a fasted state and at 2 and 4 h after meals. RESULTS: Based on both the non-invasive and VPG measurements, 93.9% (95% confidence interval 91.7-95.6%) of the blood glucose (BG) values fell within consensus error grid (CEG) zones A + B. The measurements obtained in a fasted state and at 2 h after meals were more accurate, with 99.0% and 97.0% of the BG values, respectively, falling within zones A + B. Compared to those subjects who received insulin, the proportion of values in zones A + B and the correlation coefficients were 3.1% and 0.0596 higher, respectively. The accuracy of the non-invasive glucometer was influenced by the level of insulin resistance calculated by the homeostatic model assessment method, which had a correlation coefficient with the mean absolute relative difference of - 0.1588 (P = 0.0001). CONCLUSION: The MHC-based non-invasive glucometer assessed in the present study demonstrates generally high stability and accuracy in the glucose monitoring of people with diabetes. The calculation model needs to be further explored and optimised for patients with different diabetes subtypes, levels of insulin resistance and insulin secretion capacity. CLINICAL TRIAL REGISTRY NUMBER: ChiCTR1900020523.

15.
J Pharm Anal ; 13(3): 223-238, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37102109

RESUMO

Ensuring food safety is paramount worldwide. Developing effective detection methods to ensure food safety can be challenging owing to trace hazards, long detection time, and resource-poor sites, in addition to the matrix effects of food. Personal glucose meter (PGM), a classic point-of-care testing device, possesses unique application advantages, demonstrating promise in food safety. Currently, many studies have used PGM-based biosensors and signal amplification technologies to achieve sensitive and specific detection of food hazards. Signal amplification technologies have the potential to greatly improve the analytical performance and integration of PGMs with biosensors, which is crucial for solving the challenges associated with the use of PGMs for food safety analysis. This review introduces the basic detection principle of a PGM-based sensing strategy, which consists of three key factors: target recognition, signal transduction, and signal output. Representative studies of existing PGM-based sensing strategies combined with various signal amplification technologies (nanomaterial-loaded multienzyme labeling, nucleic acid reaction, DNAzyme catalysis, responsive nanomaterial encapsulation, and others) in the field of food safety detection are reviewed. Future perspectives and potential opportunities and challenges associated with PGMs in the field of food safety are discussed. Despite the need for complex sample preparation and the lack of standardization in the field, using PGMs in combination with signal amplification technology shows promise as a rapid and cost-effective method for food safety hazard analysis.

16.
J Diabetes Sci Technol ; 17(4): 909-915, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36825611

RESUMO

BACKGROUND: Delayed initiation and inadequate titration remain critical challenges to optimizing insulin therapy in type 2 diabetes (T2D). We aimed to study whether hemoglobin A1c (HbA1c) can be lowered in people with insulin-treated T2D using telemonitoring. METHODS: This single-center study recruited adults with greater than or equal to six months of diabetes, greater than or equal to three months of insulin therapy, HbA1c ≥8.5% and ≤12.5%, and body mass index (BMI) ≤40 kg/m2. All participants received a connected glucose meter and the accompanying smartphone application. Participants sent weekly blood glucose (BG) diary to their primary endocrinologist via email. Adjustments in insulin doses were communicated to the participants. HbA1c, proportion of BG readings in range (70-180 mg/dL, PIR), below range (<70 mg/dL, PBR) and above range (>180 mg/dL, PAR), and glycemic variability as the coefficient of variation (% CV) were measured at baseline, week 12, and week 24 and compared using repeated-measures analysis of variance (ANOVA) or Friedman's ANOVA. RESULTS: We recruited 40 people (55% women). Mean age was 57.9 years, BMI 27.8 kg/m2, and baseline HbA1c 9.8% (83.7 mmol/mol). Mean HbA1c improved by 1.7%, % CV reduced from 32.9% to 30.7%, PIR increased from 58.8% to 67.1% (all P <.01) by week 24, without any change in PBR. This was achieved with a 0.04 U/kg/d median increase in total daily dose of insulin and 0.9 kg weight gain over 24 weeks. CONCLUSION: Telemonitoring and titration of insulin using a connected glucose meter resulted in significant improvements in glycemia, characterized by a reduction in HbA1c, increase in PIR, and reduction in glycemic variability without any increase in hypoglycemia.


Assuntos
Diabetes Mellitus Tipo 2 , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Masculino , Diabetes Mellitus Tipo 2/tratamento farmacológico , Insulina/uso terapêutico , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas , Glucose , Glicemia , Insulina Regular Humana/uso terapêutico
17.
Food Chem ; 407: 135161, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36502732

RESUMO

Portable and sensitive detection of carbendazim (CBD) is highly desirable for food safety and environmental protection. Herein, a portable immunosensor for the sensitive detection of CBD is proposed based on alkaline phosphatase (ALP)-labeled and secondary antibody-modified gold nanoparticles (AuNPs). The quantification is based on ALP catalyzing the dephosphorylation of glucose-1-phosphate disodium salt to generate glucose, thus converting the concentration of CBD into glucose, thereby realizing the portable detection of CBD by personal glucose meter. Benefiting from signal amplification strategy that integrates the large specific surface area of AuNPs, the enzymatic reactions of terminal deoxynucleotidyl transferase and ALP, a low detection limit of 0.37 ng/mL for CBD is achieved. When this portable method is used to analyze citrus fruit, canned citrus, and cabbage, good-consistency results are obtained with the UPLC-MS/MS method. The good performance demonstrates the great potential of this portable method for CBD monitoring in resource-poor settings.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Glucose , Imunoensaio/métodos , Ouro , Técnicas Biossensoriais/métodos , Cromatografia Líquida , Espectrometria de Massas em Tandem , Limite de Detecção
18.
Food Chem ; 400: 134007, 2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36055149

RESUMO

On-site screening of biotoxins is of great importance for food safety. A new electrochemical-biosensing strategy was constructed for ochratoxin A (OTA) detection by direct using ready-made commercial portable-glucose-meter (PGM). Aptamer against OTA was adopted as the recognition probe and pre-immobilized onto the sensing interface. The complementary biotin-modified probe was further decorated by hybridization. Biotinylated invertase was further introduced onto the sensing system with streptavidin, which also acted as the signal amplification unit. The invertase, which was depended on the amount of OTA, produced the glucose from sucrose in the sensing solution. The glucose could be directly and conveniently measured with PGM. Quantitative analysis of OTA was achieved with a linear range from 0.5 ng/mL to 10 ng/mL and detection limit of 0.45 ng/mL. Of significance, it has been successfully applied for OTA analysis in rice with satisfied recoveries. This unique PGM-based electrochemical platform reveals prospective potential in food safety monitoring.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Ocratoxinas , Oryza , Aptâmeros de Nucleotídeos/química , Biotina , Técnicas Eletroquímicas , Glucose , Limite de Detecção , Ocratoxinas/análise , Estreptavidina , Sacarose , beta-Frutofuranosidase