Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Microbiol Spectr ; 12(7): e0420123, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38842363

RESUMO

Quantitation of cytomegalovirus (CMV) DNA load in specimens other than blood such as bronchoalveolar lavages, intestinal biopsies, or urine has become a common practice as an ancillary tool for the diagnosis of CMV pneumonitis, intestinal disease, or congenital infection, respectively. Nevertheless, most commercially available CMV PCR platforms have not been validated for CMV DNA detection in these specimen types. In this study, a laboratory-developed test based on Alinity m CMV ("Alinity LDT") was evaluated. Reproducibility assessment using spiked bronchial aspirate (BAS) or urine samples showed low standard deviations of 0.08 and 0.27 Log IU/mL, respectively. Evaluating the clinical performance of Alinity LDT in comparison to a laboratory-developed test based on RealTime CMV ("RealTime LDT") showed good concordance across 200 clinical specimens including respiratory specimens, intestinal biopsies, urine, and stool. A high Pearson's correlation coefficient of r = 0.92, a low mean bias of -0.12 Log IU/mL, a good qualitative agreement of 90%, and a Cohen's kappa value of 0.76 (substantial agreement) were observed. In separate analyses of the sample types BAS, tracheal aspirates, bronchoalveolar lavage, biopsies, and urine, the assay results correlated well between the two platforms with r values between 0.88 and 0.99 and a bias <0.5 Log IU/mL. Overall, the fully automated, continuous, random access Alinity LDT yielded good reproducibility, high concordance, and good correlation to RealTime LDT in respiratory, gastrointestinal, and urine samples and may enhance patient management with rapid result reporting.IMPORTANCEIn transplant recipients, a major cause for morbidity and mortality is end-organ disease by primary or secondary CMV infection of the respiratory or gastrointestinal tract. In addition, sensorineural hearing loss and neurodevelopmental abnormalities are frequent sequelae of congenital CMV infections in newborns. Standard of care for highly sensitive detection and quantitation of the CMV DNA load in plasma and whole blood specimens is real-time PCR testing. Beyond that, there is a need for quantitative determination of CMV DNA levels in respiratory, gastrointestinal, and urinary tract specimens using a highly automated, random access CMV PCR assay with a short turnaround time to enable early diagnosis and treatment. In the present study, clinical performance of the fully automated Alinity m analyzer in comparison to the current RealTime LDT assay was evaluated in eight different off-label sample types.


Assuntos
Infecções por Citomegalovirus , Citomegalovirus , DNA Viral , Trato Gastrointestinal , Humanos , Citomegalovirus/isolamento & purificação , Citomegalovirus/genética , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/virologia , DNA Viral/genética , DNA Viral/isolamento & purificação , Reprodutibilidade dos Testes , Trato Gastrointestinal/virologia , Carga Viral/métodos , Sistema Respiratório/virologia , Líquido da Lavagem Broncoalveolar/virologia , Sensibilidade e Especificidade
2.
J Clin Microbiol ; 61(10): e0041523, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37728341

RESUMO

Monitoring of cytomegalovirus (CMV) viral load is critical for informing treatment decisions in order to prevent the severe health consequences of CMV infection or reactivation of latent CMV in immunocompromised individuals. This first field evaluation examined the analytical and clinical performance of the Alinity m CMV assay. Analytical performance was assessed with a commercially available six-member panel, while the clinical performance evaluation compared the Alinity m CMV assay to the RealTime CMV assay and a laboratory-developed test (LDT) as the test of record at three large hospital-based clinical laboratories. Precision of the Alinity m CMV assay was demonstrated with total standard deviation (SD) between 0.08 and 0.28 Log IU/mL. A total of 457 plasma specimens were tested on the Alinity m CMV assay and compared to the test of record at each site (n = 304 with RealTime CMV and n = 153 with LDT CMV). The Alinity m CMV assay had excellent correlation (correlation coefficient r ≥0.942) in comparison to the RealTime CMV or LDT CMV assays. The mean observed bias ranged from -0.03 to 0.34 Log IU/mL. Median onboard turnaround time of Alinity m CMV was less than 3 h. When the CMV assay is run on the Alinity m system, it has the capacity to shorten time to result and, therefore, to therapy.


Assuntos
Infecções por Citomegalovirus , Citomegalovirus , Humanos , Citomegalovirus/genética , Carga Viral , Infecções por Citomegalovirus/diagnóstico , DNA , Hospedeiro Imunocomprometido , DNA Viral/genética , Sensibilidade e Especificidade
3.
J Clin Microbiol ; 61(10): e0047223, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37728343

RESUMO

Detection and monitoring of acute infection or reactivation of Epstein-Barr virus (EBV) are critical for treatment decision-making and to reduce the risk of EBV-related malignancies and other associated diseases in immunocompromised individuals. The analytical and clinical performance of the Alinity m EBV assay was evaluated at two independent study sites; analytical performance was assessed by evaluating precision with a commercially available 5-member EBV verification panel, while the clinical performance of the Alinity m EBV assay was compared to the RealTime EBV assay and a laboratory-developed test (LDT) as the routine test of record (TOR). Analytical analysis demonstrated standard deviation (SD) between 0.08 and 0.13 Log IU/mL. A total of 300 remnant plasma specimens were retested with the Alinity m EBV assay, and results were compared to those of the TOR at the respective study sites (n = 148 with the RealTime EBV assay and n = 152 with the LDT EBV assay). Agreement between Alinity m EBV and RealTime EBV or LDT EBV assays had kappa values of 0.88 and 0.84, respectively, with correlation coefficients r of 0.956 and 0.912, while the corresponding observed mean bias was -0.02 and -0.19 Log IU/mL. The Alinity m EBV assay had a short median onboard turnaround time of 2:40 h. Thus, the Alinity m system can shorten the time to results and, therefore, to therapy.


Assuntos
Infecções por Vírus Epstein-Barr , Herpesvirus Humano 4 , Humanos , Herpesvirus Humano 4/genética , Infecções por Vírus Epstein-Barr/diagnóstico , DNA Viral , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA