Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 399
Filtrar
1.
Rev Bras Ortop (Sao Paulo) ; 59(Suppl 1): e17-e21, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39027180

RESUMO

Although the relationship between hip arthroplasty and the development of sarcoma was first described in the literature about forty years ago, this association is extremely rare. In the present case report, we describe the association between orthopedic implants and soft tissue sarcoma in a 79-year-old man who underwent primary total hip arthroplasty (THA) for coxarthrosis 24 years ago. In the present case report, we describe the clinical evolution and the radiographic and histopathological findings of the lesion. In the intraoperative period of the second revision surgery, loosening of the acetabular and femoral components in association with extensive areas of necrosis and metallosis was evidenced. We performed debridement of the hip and right thigh region and removed the implants. Due to the extent of the lesion and to necrosis, it was not possible to perform a new joint reconstruction. The histopathological diagnosis of high-grade undifferentiated pleomorphic sarcoma associated with extensive areas of metallosis was confirmed in tissue adjacent to the implant. The patient developed pulmonary metastases and died 6 months after the diagnosis. Despite the rarity of this association, sarcomas should be considered in the differential diagnosis of aseptic loosening, especially in the presence of metallosis in the peri-implant tissue. To our knowledge, the 24-year latency period between primary THA and the establishment of a sarcoma diagnosis is one of the longest reported to date.

2.
Rev Bras Ortop (Sao Paulo) ; 59(Suppl 1): e78-e82, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39027182

RESUMO

The following case report aims to demonstrate a total hip arthroplasty revision surgery (THARS) using a custom-made trabecular metal acetabular component for correction of a severe acetabular defect. Currently, in the literature, there are few complete descriptions of surgical planning and procedures involving customized prostheses. This is due to the inherent technical difficulty of the surgical procedure and the high costs related to the planning and materials.

3.
Clin Case Rep ; 12(8): e9195, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39055088

RESUMO

Key Clinical Message: Despite being rare, we have presented a case of osteonecrosis of acetabulum that followed total hip arthroplasty. It's crucial to act appropriately, as it emulates periprosthetic joint infection. The key point is that the osteonecrosis of acetabulum may necessitate revision and can be classified as aseptic loosening. Abstract: Osteonecrosis of the femoral head is well known and managed with total hip arthroplasty (THA). Acetabulum osteonecrosis can be classified as a cause of painful THA and the cemented acetabular component is a feasible option. However, it seems that the osteonecrosis of acetabulum is sparsely alluded in literature. In this case report sustaining of the right hip pain following THA of 35-year-old woman is discussed.

4.
Abdom Radiol (NY) ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38980403

RESUMO

OBJECTIVES: To compare the image quality of 1.5T and 3T prostate MRIs of the same post-hip arthroplasty patients, with a specific focus on the degree of susceptibility artifacts. METHODS: This single-center retrospective study included post-hip arthroplasty patients who underwent 1.5T prostate MRIs between 2021 and 2023, as well as comparative 3T prostate MRIs. Three blinded abdominal radiologists retrospectively reviewed their diffusion-weighted imaging (DWI, 50 s/mm2), T2-weighted imaging (T2WI), and dynamic contrast-enhanced imaging (DCE) to evaluate the image quality. The degree of susceptibility artifacts was categorized using a three-point scale, with 3 indicating the least artifact and 1 indicating the most. Image quality was also evaluated using Prostate Imaging Quality (PI-QUAL) version 2. The median of the three raters' scores was compared between 1.5T and 3T prostate MRIs using the Wilcoxon signed-rank test. The inter-rater agreement was evaluated using the multi-rater generalized kappa. RESULTS: Twenty pairs of 1.5T and 3T prostate MRI examinations from 20 unique patients were included. The DWI susceptibility artifact score at 1.5T was significantly higher than at 3T (mean score ± standard deviation, 2.80 ± 0.41 vs. 2.35 ± 0.93, p = 0.014). In contrast, no significant differences were observed in the susceptibility artifact scores in T2WI and DCE, or in the PI-QUAL score. The inter-reader agreement in the susceptibility artifact score was moderate (multi-rater generalized kappa: 0.60) in DWI, perfect in T2WI (not applicable), and substantial (0.65) in DCE. The inter-reader agreement was fair (0.27) in the PI-QUAL score. CONCLUSION: Using 1.5T scanners may be preferable to reduce susceptibility artifacts from hip prostheses in DWI.

5.
Hip Pelvis ; 36(2): 120-128, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38825821

RESUMO

Purpose: The purpose of this study was to compare the clinical and radiographic outcomes with use of short-curved stems versus standard-length single wedged stems over a minimum follow-up period of five years. Materials and Methods: A retrospective study of primary total hip arthroplasties performed using the Fitmore® stem (127 hips, 122 patients) and the M/L taper® stem (195 hips, 187 patients) between October 2012 and June 2014 was conducted. The clinical and radiographic outcomes were obtained for evaluation over a minimum follow-up period of five years. Results: In both the Fitmore® and M/L taper® groups, the mean Harris hip score improved from 52.4 and 48.9 preoperatively to 93.3 and 94.5 at the final follow-up, respectively (P=0.980). The mean Western Ontario and McMaster Universities Osteoarthritis Index scores also improved from 73.3 and 76.8 preoperatively to 22.9 and 25.6 at the final follow-up, respectively (P=0.465). Fifteen hips (Fitmore®: 14 hips; M/L taper®: one hip, P<0.001) developed intraoperative cracks and were treated simultaneously with cerclage wiring. Radiography showed a radiolucent line in 24 hips in the Fitmore® group and 12 hips in the M/L taper® group (P=0.125). Cortical hypertrophy was detected in 29 hips (Fitmore® group: 28 hips; M/L taper® group: one hip, P<0.001). Conclusion: Similarly favorable clinical and radiographic outcomes were achieved with use of both short-curved stems and standard-length single wedged stems. However, higher cortical hypertrophy and a higher rate of femoral crack were observed with use of Fitmore® stems.

6.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38880356

RESUMO

INTRODUCTION AND OBJECTIVE: Hip arthroplasty represents a significant advancement in the treatment of refractory chronic joint pain, improving quality of life and functionality. The objective of this study is to identify the risk factors associated with local and systemic complications in patients treated with total hip arthroplasty. METHODS: Observational, analytical, retrospective cohort study, which included 304 participants treated with total hip replacement. Comparison of variables between two groups was performed; 38 participants in the group with complications and 266 participants in the group without complications. RESULTS: The mean age in the complication group was 66 years (SD 18.7) and in the uncomplicated group it was 67,1 years (SD 15.1) (p 0,686). Female sex was observed in 73.3% of the group with complications and 65% in the group without complications. (p 0.292). Risk factors were: hip fracture as an indication for arthroplasty RR 1.33 [95% CI 1.004;1.775 p 0.047], coronary heart disease RR 1.31 [95% CI 1.067;1.616 p 0.010] and surgical bleeding equal to or greater than 400 cc RR 1.11 [95% CI 1.012;1.218 p 0.028]. CONCLUSIONS: The risk factors for complications in total hip arthroplasty were: hip fracture as the indication for arthroplasty, coronary artery disease, and surgical bleeding equal to or greater than 400 cc.

7.
Int J Orthop Trauma Nurs ; 54: 101119, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38925028

RESUMO

OBJECTIVE: This study aims to present the developmental stages of a Mobile App Prototype designed to enhance patient participation in the rehabilitation process after hip replacement. METHODS: To ensure effective interaction between the system and the end user, a User-Centered Design methodology was followed, encompassing three phases: Requirements gathering, Prototyping, and Evaluation. Usability tests were conducted to assess the usability of the developed system. RESULTS: The RehabApp for mobile devices was created, and the testing results were positive. Users expressed satisfaction with the outcome, deeming it a valuable tool for their recovery. This outcome demonstrates the high receptiveness of these technologies in the healthcare sector, making it a project that can readily be expanded into other areas of rehabilitation. CONCLUSION: This study demonstrated the potential of the RehabApp in the rehabilitation process after hip replacement surgery. This accomplishment was realized by ensuring the active participation of patients, potential users, and healthcare professionals throughout the app's development. INNOVATION: The RehabApp is a mobile application to provide users with all the necessary knowledge, enabling them to undergo a smoother and safer rehabilitation. Feedback from both patients and healthcare professionals played a crucial role in refining the app's features and addressing usability concerns.

8.
J Mech Behav Biomed Mater ; 157: 106640, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38917558

RESUMO

After total hip arthroplasty, the stress shielding effect can occur due to the difference of stiffness between the metallic alloy of the stems and the host bone, which may cause a proximal bone loss. To overcome this problem, a low-modulus metastable ß Ti-20Zr-3Mo-3Sn alloy composition has recently been designed to be potentially used for the cementless femoral hip stems. After having verified experimentally that the ß alloy has a low modulus of around 50 GPa, a finite element analysis was performed on a Ti-20Zr-3Mo-3Sn alloy hip prosthesis model to evaluate the influence of a reduced modulus on stress shielding and stress fields in both stem and bone compared with the medical grade Ti-6Al-4V alloy whose elastic modulus reached 110 GPa. Our results show that the Ti-20Zr-3Mo-3Sn stem with low elastic modulus can effectively reduce the total stress shielding by 45.5% compared to the common Ti-6Al-4V prosthesis. Moreover, it is highlighted that the material elasticity affects the stress distribution in the implant, especially near the bone-stem interfaces.


Assuntos
Ligas , Análise de Elementos Finitos , Prótese de Quadril , Teste de Materiais , Estresse Mecânico , Titânio , Ligas/química , Titânio/química , Módulo de Elasticidade , Desenho de Prótese , Zircônio/química
9.
Urol Case Rep ; 54: 102743, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38706875

RESUMO

Bladder injuries, although rare, can occur as a complication of hip surgery, particularly when a hip prosthesis migrates into the bladder. We present the case of a 75-year-old woman with a bladder rupture secondary to prosthesis migration requiring repair via a transvesical approach. While total hip arthroplasty (THA) is common, intrapelvic complications such as bladder injury are less commonly reported. Early recognition and appropriate treatment are essential to avoid serious consequences. The management of prosthesis migration into the bladder is complex and requires detailed anatomical knowledge. Awareness of this potential complication is essential for both orthopaedic surgeons and urologists.

10.
Kans J Med ; 17: 30-33, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38694181

RESUMO

Introduction: Traditional mallet broaching and stem seating in cementless total hip arthroplasty (THA) can result in femoral stem misalignment, potentially reducing implant longevity. This study aimed to compare the pullout strength of cementless THA femoral stems with different cross-sectional designs achieved through the powered impactor method versus the traditional mallet method. Methods: The authors utilized 24 polyurethane foam femurs and two femoral bone preservation stems with different proximal cross-sectional shapes (double taper: ACTIS®, size 5; flat taper: TRI-LOCK®, size 5). A single orthopedic surgeon broached each femur from size 0 to size 5 using either the powered impactor or mallet impaction methods. Broaching time and component implantation times were recorded. A load-to-failure pullout strength test was conducted, and the ultimate pullout load was recorded. Results: The broaching time for the TRI-LOCK® stem showed a statistically significant difference between the two impaction methods (powered: 37±7 seconds, mallet: 75±29 seconds, F[3, 20] = 4.56, p = 0.002), but no statistically significant difference was detected for the ACTIS® stem between the two impaction methods (powered: 47±22 seconds, mallet: 59±9 seconds, F[3, 20] = 4.56, p = 0.304). There was a statistically significant difference in pullout strength between the two impaction groups, and this strength was influenced by the implant cross-sectional shape (ACTIS®: 774±75N versus 679±22N, F(3,20) = 16.38, p = 0.018; TRI-LOCK®: 616±57N versus 859±85N, F(3, 20) = 16.38, p <0.001). Conclusions: The technique used for femoral bone preparation (powered impactor versus mallet) and the cross-sectional design of the cementless femoral stem are crucial factors that affect initial stem stability and operation time.

11.
J Arthroplasty ; 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38710344

RESUMO

BACKGROUND: Total hip arthroplasty (THA) for femoral neck fracture (FNF) can be performed through different surgical approaches. This study compared the revision rates and patient-reported outcome measures by surgical approach. METHODS: Data from the New Zealand Joint Registry were analyzed for patients undergoing primary THA for FNF from January 2000 to December 2021. A total of 5,025 THAs were performed for FNF; the lateral approach was used in 2,499 (49.7%), the posterior in 2,255 (44.9%), and the anterior in 271 (4.3%). The primary outcome measure was the all-cause revision rate. Secondary outcome measures included revision rates for: dislocation, aseptic femoral component loosening, periprosthetic fracture, and infection. Oxford Hip Scores (OHS) were also collected. Age, sex, body mass index, American Society of Anesthesiologists score, femoral head size, dual mobility use, femoral fixation, and surgeon experience were assessed as potential confounding variables. RESULTS: There was no difference in the revision rates between lateral and posterior (P = .156), lateral and anterior (P = .680), or posterior and anterior (P = .714) approaches. There was no difference in the reasons for revision between the lateral and posterior approaches or 6-month OHS (P = .712). There was insufficient data to compare the anterior approach. CONCLUSIONS: There is no difference in the overall revision rates, reasons for revision, or OHS between the lateral and posterior surgical approaches for THA performed for FNF. Insufficient data on the anterior approach is available for an accurate comparison. LEVEL OF EVIDENCE: Level III.

12.
Proc Inst Mech Eng H ; 238(5): 471-482, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38644528

RESUMO

The use of uncemented stems in hip arthroplasty has been increasing, even in osteoporotic patients. The major concerns of uncemented hip-stems, however, are peri-prosthetic fracture, thigh pain, and proximal femoral stress-/strain-shielding. In this study, a novel design of uncemented hip-stem is proposed that will reduce such concerns, improve osseointegration, and benefit both osteoporotic and arthritic patients. The stem has a central titanium alloy core surrounded by a set of radial buttresses that are partly porous titanium, as is the stem tip. The aim of the study was to investigate the mechanical behaviour of the proposed partly-porous design, examining load transfer in the short-term, and comparing its strain-shielding behaviour with a solid metal implant. The long-term effect of implant-induced bone remodelling was also simulated. Computed tomography based three-dimensional finite element models of an intact proximal femur, and the same femur implanted with the proposed design, were developed. Peak hip contact and major muscle forces corresponding to level-walking and stair climbing were applied. The proposed partly-porous design had approximately 50% lower strain-shielding than the solid-metal counterpart. Results of bone remodelling simulation indicated that only 16% of the total bone volume is subjected to reduction of bone density. Strain concentrations were observed in the bone around the stem-tip for both solid and porous implants; however, it was less prominent for the porous design. Lower strain-shielding and reduced bone resorption are advantageous for long-term fixation, and the reduced strain concentration around the stem-tip indicates a lower risk of peri-prosthetic fracture.


Assuntos
Análise de Elementos Finitos , Prótese de Quadril , Desenho de Prótese , Estresse Mecânico , Humanos , Artroplastia de Quadril/instrumentação , Porosidade , Fêmur/cirurgia , Teste de Materiais
13.
Biochem Med (Zagreb) ; 34(2): 021001, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38665872

RESUMO

A patient presented with fever, severe pain and edematous tight due to hip trauma and was scheduled for urgent fasciotomy. Following physical examination, laboratory analyses were requested, and results revealed anemia and severe infection. As the patient's condition was serious, a new set of samples was sent to the laboratory four hours later. Following centrifugation, severely hemolyzed dark-colored serum and plasma samples were obtained and in vitro hemolysis was suspected. The collection of samples was repeated, but a new set of samples was also hemolyzed with a significant decrease in the hemoglobin value. At that point, in vivo hemolysis was suspected, and samples were processed according to standard laboratory procedures for hemolytic samples. Following confirmation of the gas gangrene diagnosis by clinicians, the cause of hemolysis was attributed to the cytotoxic activity of α-toxin produced by the anaerobic gram-positive bacterium Clostridium perfringens. An insight into the laboratory procedure that could help to narrow down the causes of hemolysis and single out C. perfringens as a cause of intravascular hemolysis was given.


Assuntos
Clostridium perfringens , Gangrena Gasosa , Hemólise , Humanos , Clostridium perfringens/isolamento & purificação , Gangrena Gasosa/diagnóstico , Masculino , Infecções por Clostridium/diagnóstico , Infecções por Clostridium/sangue
14.
Rev Bras Ortop (Sao Paulo) ; 59(1): e21-e28, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38524719

RESUMO

Hip arthroplasties are surgical procedures widely performed all over the world, seeking to return functionality, relieve pain, and improve the quality of life of patients affected by osteoarthritis, femoral neck fractures, osteonecrosis of the femoral head, among other etiologies. Periprosthetic joint infections are one of the most feared complications due to the high associated morbidity and mortality, with a high number of pathogens that may be associated with its etiology. The aim of the present study was to analyze aspects correlated with the occurrence of infection, diagnosis and prevention of periprosthetic joint infections in the hip associated with Staphylococcus aureus after corrective surgery for hip fractures. This is a systematic review of the literature carried out in the databases indexed in the Medical Literature Analysis and Retrieval System Online (MEDLINE) carried out in accordance with the precepts established by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) methodology. Twenty studies that addressed the diagnosis and prevention of periprosthetic joint infections after hip fractures were selected for analysis. It is observed that there is no consensus in the literature on preventive measures for the occurrence of such infectious processes. Among the risk factors for the occurrence and severity of infections by S. aureus after hip arthroplasties, obesity, longer surgical time, older age, immunosuppression, recent use of antibiotics, and multicomorbidities were mentioned. The use of biomarkers for early diagnosis, as well as screening, decolonization, and antibiotic prophylaxis processes are among the preventive procedures proposed in the literature.

15.
J Med Cases ; 15(1): 20-25, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38328808

RESUMO

This case report explores a unique presentation of hip dysplasia in a female patient aged 21 years old diagnosed with Charcot-Marie-Tooth disease (CMT) type 1A and multiple acyl-CoA dehydrogenase deficiency (MADD). The coexistence of these neuromuscular and metabolic disorders in a patient with hip dysplasia provides an opportunity to investigate their potential interactions and impact on diagnosis, treatment, and prognosis. The patient underwent labral repair with shelf osteotomy and later a total hip replacement. This case highlights the need for further research to better understand the relationships between CMT, MADD, neuromuscular dysplasia, and hip dysplasia. A deeper understanding of these interactions may lead to improved diagnostic techniques, earlier intervention, and personalized treatment approaches for patients with co-morbid conditions, ultimately improving patient outcomes and reducing complications later in life.

16.
Hip Int ; 34(2): 221-227, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38414223

RESUMO

BACKGROUND AND AIM: Several studies reported osteolysis around polyethylene glycol/polybutylene terephthalate (PEG/PBT) based femoral cement restrictors. Our goal was to evaluate and compare osteolysis around 3 different plug designs: the slow biodegradable PEG/PBT cement restrictor; the fast biodegradable gelatin cement restrictor; and the non-biodegradable polyethylene plug. PATIENTS AND METHODS: In a retrospective multicentre cohort study chart data were extracted of patients who received a total hip arthroplasty between 2008 and 2012. A total of 961 hips were included. Cortical ratio between inner and outer cortices at the centre of the plug was measured on routine postoperative follow-up moments. Median follow up of all 3 hospitals was 3.5 years (1.4-7.3). The primary outcome was evidence of osteolysis (i.e. the difference in cortical ratio [CR]) on anteroposterior (AP) radiographs at final follow-up. RESULTS: Progressive osteolysis was found around the PEG/PBT cement restrictor represented by a significantly increasing cortical ratio (ΔCR 0.067 (95% CI, 0.063-0.071). Distance from tip prosthesis to plug and size of the plug were found to be independent factors in predicting increased cortical ratio. CONCLUSIONS: Our multicentre cohort shows increase of cortical ratio around the PEG/PBT cement restrictor which progresses over time. Physicians should be aware of this fact and are advised to intensify follow-up of patients who received this cement restrictor.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Humanos , Artroplastia de Quadril/efeitos adversos , Estudos de Coortes , Osteólise/induzido quimicamente , Osteólise/diagnóstico por imagem , Cimentação , Polietileno , Cimentos Ósseos/efeitos adversos , Prótese de Quadril/efeitos adversos , Seguimentos , Falha de Prótese , Desenho de Prótese
17.
EFORT Open Rev ; 9(2): 107-118, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38310694

RESUMO

Purpose: The association between preoperative expectations and treatment outcomes in total hip arthroplasty (THA) or total knee arthroplasty (TKA) is still unclear. Therefore the aim is to examine the association between preoperative outcome expectations, process expectations, and self-efficacy, and the postoperative outcomes overall outcome, pain, function, stiffness, satisfaction, and quality of life following THA/TKA. Methods: A systematic review with narrative synthesis was conducted. PubMed, EMBASE, PsycINFO, CINAHL and Cochrane Library were searched from inception to October 17, 2022. Included were prospective longitudinal cohort studies published in English, German, or Dutch, with an adult population undergoing THA/TKA, and including at least one measure of preoperative expectations and the postoperative outcomes mentioned earlier. Two independent reviewers screened the retrieved articles for eligibility, a third solved disagreements. Risk of bias (RoB) was assessed using the QUIPS tool. Results: Of the 50 included studies, 38 had high RoB and 12 moderate RoB. Unadjusted results suggest a positive association between preoperative outcome expectations and overall outcome in the medium and long term, and between self-efficacy and change in 'overall outcome' in the long term. Adjusted results suggest positive associations between outcome expectations and function and between self-efficacy and overall outcome in the medium term, and for outcome expectations with pain and change in pain, respectively, and self-efficacy and stiffness in the long term. Conclusions: Preoperative expectations show a possible positive association with specific outcome measures, such as pain or function. For future research, it is advised to link matching specific expectations with specific outcomes.

18.
Unfallchirurgie (Heidelb) ; 127(5): 335-342, 2024 May.
Artigo em Alemão | MEDLINE | ID: mdl-38413428

RESUMO

Proximal femoral fractures occur at an annual incidence of approximately 200/100,000 inhabitants and mortality rates range up to 30% especially in geriatric patients where complications are not necessarily associated to surgery. In nearly all cases surgical treatment is required. Procedures to preserve the femoral head have to be performed as early as possible (as specified by the Federal Joint Committee, GBA, within 24 h). For joint-preserving approaches in medial femoral neck fractures a time to surgery within 6 h is considered to be advantageous. Perioperative patient care is of high importance regarding the prevention of pneumonia, renal failure, delirium and further complications. Postoperatively full weight bearing enables for early mobilization and prevention of surgery-related complications. Nonunions, avascular necrosis of the femoral head, cut-out and prosthetic dislocation must be avoided by the selection of the appropriate procedure. Minimally displaced femoral neck fractures are primarily treated by osteosynthesis and conservative management is only considered in isolated cases. For displaced femoral neck fractures, factors such as a young biological age with high activity levels, the absence of arthritis and good bone quality with a successful reduction favor for a femoral head-preserving osteosynthesis. Otherwise, (hybrid) total hip replacement (THR) is the preferred method for unstable and displaced fractures, whereby hemiarthroplasty should only be considered for very old and patients with pre-existing diseases. Fractures in the trochanteric region are treated with a proximal femoral nail and subtrochanteric fractures are managed using a long proximal femoral nail. To avoid secondary complications, the choice of optimal treatment should be based on a good understanding of the injury pattern, biomechanical and technical aspects of each procedure.


Assuntos
Fixação Interna de Fraturas , Humanos , Fixação Interna de Fraturas/métodos , Artroplastia de Quadril/métodos , Fraturas do Colo Femoral/cirurgia , Fraturas do Quadril/cirurgia , Resultado do Tratamento , Fraturas Proximais do Fêmur
19.
Cureus ; 16(1): e52242, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38352088

RESUMO

Total hip arthroplasty remains the treatment of last resort in inflammatory coxarthritis, where joint destruction is bilateral as well as the treatment which must be bilateral. We present in this work the experience of our orthopaedic department with a series of five cases (10 hips) operated for total hip arthroplasty. the first particularity observed in this series is the abnormal bone fragility present in 55% of the cases. For this reason, we had two other intraoperative complications that are related to this bone fragility, during the preparation of the acetabulum, we had a destruction of the medial wall by the burr that went unnoticed intraoperatively and was discovered during the patient's recovery from acute ischemia secondary to the burr, which led to an extensive rupture of the common femoral vein and partial sectioning of the common femoral artery. We also had an exceptional incident in a case with two ankylosed hips; in fact, when the approach was performed, the sciatic nerve was found pressed against the posterior surface of the greater trochanter, which was unusual but was explained by the retraction of the structures of the gluteal region secondary to prolonged immobilization. Thus, there was one case of cement shock manifested by hypotension occurring immediately after cement placement. In front of this inflammatory disease and ankylosis terrain, the surgeon must always be prepared for any complication and must keep in mind that he is operating on a hip that is anatomically not normal due to ankylosis and retraction of the vascular, nerve, and muscle structures.

20.
Cancers (Basel) ; 16(2)2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38254818

RESUMO

PURPOSE: Given that the current standard of proton therapy (PT) for prostate cancer is through bilateral beams, this modality is typically avoided when it comes to treatment of patients with hip prosthesis. The purpose of this study was to evaluate whether novel PT methods, i.e., anterior proton beams and proton arc therapy (PArc), could be feasible options to treat this patient subpopulation. We evaluate PT methods in the context of dosimetry and robustness and compare with standard of practice volumetric modulated arc therapy (VMAT) to explore any potential benefits. METHODS: Two PT and one VMAT treatment plans were retrospectively created for 10 patients who participated in a clinical trial with a weekly repeat CT (rCT) imaging component. All plans were robustly optimized and featured: (1) combination anterior oblique and lateral proton beams (AoL), (2) PArc, and (3) VMAT. All patients had hydrogel spacers in place, which enabled safe application of anterior proton beams. The planned dose was 70 Gy (RBE) to the entire prostate gland and 50 Gy (RBE) to the proximal seminal vesicles in 28 fractions. Along with plan dose-volume metrics, robustness to setup and interfractional variations were evaluated using the weekly rCT images. The linear energy transfer (LET)-weighted dose was evaluated for PArc plans to ensure urethra sparing given the typical high-LET region at the end of range. RESULTS: Both PT methods were dosimetrically feasible and provided reduction of some key OAR metrics compared to VMAT except for penile bulb, while providing equally good target coverage. Significant differences in median rectum V35 (22-25%), penile bulb Dmean (5 Gy), rectum V61 (2%), right femoral head Dmean (5 Gy), and bladder V39 (4%) were found between PT and VMAT. All plans were equally robust to variations. LET-weighted dose in urethra was equivalent to the physical dose for PArc plans and hence no added urethral toxicity was expected. CONCLUSIONS: PT for treatment of prostate cancer patients with hip prosthesis is feasible and equivalent or potentially superior to VMAT in quality in some cases. The choice of radiotherapy regimen can be personalized based on patient characteristics to achieve the best treatment outcome.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA