RESUMO
Polyglucosan bodies are accumulations of insoluble glucose polymers and proteins that form intracytoplasmic inclusions in the brain, large numbers of which can be indicative of neurodegenerative diseases such as Lafora disease. Montserrat orioles (Icterus oberi) are an icterid passerine endemic to Montserrat with conservation populations maintained in captivity abroad. We demonstrate that polyglucosan bodies are unusually abundant in the cerebellar molecular and Purkinje cell layers and cerebellar peduncles of captive-bred and wild-caught Montserrat orioles. The bodies are periodic acid-Schiff positive and diastase resistant and label with concanavalin A and for ubiquitin, consistent with those seen in humans. We found no association of the polyglucosan bodies with concurrent neurological lesions or clinical signs, nor with EPM2A and EPM2B gene mutations associated with Lafora disease. We conclude that an abundance of cerebellar polyglucosan bodies may be a normal finding in aged Montserrat orioles and not a threat to the captive breeding population.
RESUMO
OBJECTIVES: This study aimed to analyse the clinical course of 45 children with severe alpha-1-antitrypsin deficiency (AATD) registered in our clinic to detect possible predictors of poor outcomes. METHODS: The clinical and biological data of 45 patients with homozygous or compound heterozygous AATD were analysed. The data were collected retrospectively going back to 2005 and prospectively from May 2020 until October 2021. It was based on questionnaires, laboratory values, sonography, and biopsy findings. Liver disease was classified into four grades depending on the grade of liver disease: mild or no liver disease, moderate disease, severe disease, and liver transplantation. RESULTS: Thirty-nine patients (86.7%) had a Pi*ZZ and five (11.1%) a Pi*SZ genotype. One patient showed a new, not-yet-described compound heterozygous genotype (Pi*Z + Asp95Asn). A total of 66.7% of the cohort showed mild or no liver disease, 20% moderate, and 13.3% severe. AATD was diagnosed in most cases because of liver abnormalities, such as the elevation of transaminases (42.2%). A total of 29.4% of the patients with neonatal icterus prolongatus developed severe liver disease, and 25.7% were born small for their gestational age (SGA). Diseases of the atopic type were reported in 47.4% of the cases. CONCLUSIONS: The presence of neonatal icterus prolongatus in the first weeks of life was significantly more likely in severe courses of liver disease (r = 0.371, p = 0.012). A tendency toward atopic comorbidity in AAT-deficient children needs to be further evaluated.
RESUMO
OBJECTIVES: The aims of this study were to (1) establish the maximum allowable interference limits for hemolysis, lipemia, and icterus for chemistry analytes tested in body fluid samples and (2) assess the effectiveness of serial dilution to mitigate spectral interferences. METHODS: Residual body fluids from clinically ordered testing were mixed (<10% by volume) with stock solutions of interferent (spiked) and compared with a control spiked with an equal volume of 0.9% saline. The analytes were measured on the Roche cobas c501 instrument. Difference and percentage difference were calculated and compared with allowable total error limits. A subset of samples were serially diluted with 0.9% saline. Mean (SD) difference and percentage difference were calculated. RESULTS: The interference thresholds were lower than the package insert for lactate dehydrogenase, cholesterol, triglycerides, and total protein for hemolysis; amylase, cholesterol, and total protein for icterus; and albumin for lipemia. Only cholesterol and triglyceride results returned to baseline upon dilution of icteric samples. CONCLUSIONS: Interference thresholds in body fluids were lower than blood for 6 analytes. Diluting interferences that surpass these limits does not produce reliable results that are comparable to the baseline results before spiking in the interferent.
Assuntos
Hemólise , Hiperlipidemias , Icterícia , Humanos , Hiperlipidemias/sangue , Hiperlipidemias/diagnóstico , Icterícia/diagnóstico , Icterícia/sangue , Líquidos Corporais/química , Triglicerídeos/sangue , Triglicerídeos/análise , Colesterol/sangue , Colesterol/análiseRESUMO
BACKGROUND: Total serum bilirubin concentration (TBIL) can provide useful information on several pathophysiological conditions in cats. Nevertheless, whether the variable severity classification of hyperbilirubinemia can reliably indicate certain disease processes or predict a biliary obstruction (BO) has not been investigated. HYPOTHESIS/OBJECTIVE: Determine if hyperbilirubinemia of variable severity can assist clinicians to identify BO, which often is considered a surgical emergency. ANIMALS: Two-hundred sixteen client-owned cats. METHODS: Data were retrospectively collected from all cats (January 2015-August 2022) with an increased TBIL (>0.58 mg/dL [>10 µmol/L]) presented to 3 referral centers in the United Kingdom (UK). Presenting clinical features and diagnostic outcomes were collected. The predictive ability of TBIL to indicate BO was evaluated by multivariable binary logistic regression modeling and receiver operating characteristic (ROC) curves. RESULTS: Median TBIL was 1.73 mg/dL (range, 0.59-26.15; 29.5 µmol/L; range, 10.1-447.1) with severity classification of hyperbilirubinemia categorized as mild (>0.58-2.92 mg/dL; >10-50 µmol/L; 68.1%), moderate (>2.92-5.85 mg/dL; >50-100 µmol/L; 17.6%), severe (>5.85-11.70 mg/dL; >100-200 µmol/L; 9.7%) and very severe (>11.70 mg/dL; >200 µmol/L; 4.6%). Biliary obstruction was present in 17 (7.9%) cats, all of which received recommendation for emergency surgery. Median TBIL in cats with BO (9.69 mg/dL; 165.7 µmol/L) differed significantly from those without obstruction (1.51 mg/dL; 25.8 µmol/L; P < .01). The optimal TBIL cut-off to discriminate between cats with and without BO was ≥3.86 mg/dL (≥66 µmol/L) with a sensitivity of 94.1% and specificity of 82.4%. Using multivariable logistic regression, as age increased, the odds of BO increased significantly (odds ratio, 1.20; 95% confidence interval, 1.01-1.42; P = .04). CONCLUSIONS AND CLINICAL IMPORTANCE: As part of a thorough clinical assessment, the severity classification of hyperbilirubinemia has the potential to predict the likelihood of a BO and to discriminate between cats that may or may not require surgery for BO at a suggested cut-off of ≥3.86 mg/dL (≥66 µmol/L). Alongside TBIL, age is also useful when assessing for the likelihood of BO in a cat presented with hyperbilirubinemia.
Assuntos
Doenças do Gato , Colestase , Animais , Gatos , Bilirrubina , Doenças do Gato/diagnóstico , Colestase/veterinária , Hiperbilirrubinemia/diagnóstico , Hiperbilirrubinemia/veterinária , Estudos Retrospectivos , Reino UnidoRESUMO
OBJECTIVES: To compare the performance of Modified Kramer's and Kramer's methods in terms of agreement with total serum bilirubin (TSB). METHODS: This cross-sectional study was done in Level-III neonatal unit in New Delhi. Visibly jaundiced neonates born at ≥35 wk of gestation were enrolled and examined by (i) conventional Kramer's, (ii) Modified Kramer's in artificial (MK-A) and (iii) natural daylight (MK-N), and finally sampled for estimation of TSB by point-of-care spectrophotometry. The primary outcomes were agreement of Kramer's and Modified Kramer's with TSB and accuracy in terms of proportion of bilirubin estimates lying within ±2 mg/dL of TSB; secondary outcome was agreement of MK-A and MK-N with TSB. RESULTS: A total of 144 neonates with median gestation of 37 wk and mean birth weight of 2788 g were enrolled. Bland Altman analysis between Kramer's and TSB yielded mean difference of 1.7 mg/dL, 95% limits of agreement (LOA) -3.1 to 6.6 mg/dL. For Modified Kramer's and TSB, mean difference was -0.02 mg/dL, 95% LOA -4.7 to 4.7 mg/dL under artificial light; 0.02 mg/dL, 95% LOA -4.2 to 4.2 mg/dL under natural daylight. MK-N had highest proportion of bilirubin estimates lying within ±2 mg/dL of TSB (68.7%) as compared to MK-A (59.7%) [OR, 1.77; 95% CI, 1.09 to 2.86] and Kramer's (45.8%) [OR, 1.65; 95% CI, 1.27 to 2.15]. CONCLUSIONS: Though all the three methods had poor agreement with TSB, Modified Kramer's method when performed in natural light had reasonable accuracy, however limited clinical utility, in evaluation of clinical jaundice.
RESUMO
Introduction: Icterus, if not detected, can affect the validity of results delivered by clinical laboratories, leading to erroneous results. This study aims to define bilirubin interference for some biochemical analytes and compare it with the manufacturer's data. Material and methods: Serum pools prepared with outpatients' samples were spiked with increasing bilirubin concentration (Merck, reference14370, Darmstadt, Germany) up to 513 µmol/L in order to evaluate the bias for the following biochemical analytes: creatinine (CREA), creatine kinase (CK), cholesterol (CHOL), gamma-glutamyltransferase (GGT), high-density lipoprotein cholesterol (HDL), and total protein (TP). For each analyte, six pools of different concentrations were prepared. Measurements were made employing Cobas 8000 analyser c702-502, Roche Diagnostics (Mannheim, Germany). This study employed a study procedure defined by the Spanish Society of Laboratory Medicine. Results: Obtained bilirubin concentrations producing a negative interference were 103 µmol/L for CHOL, 205 µmol/L for TP and 410 µmol/L for CK, but only for CK values less than 100 U/L. Bilirubin concentrations lower than 513 µmol/L do not produce interference for HDL and GGT. Finally, for the studied bilirubin concentrations, there is no interference for CREA higher than 80 µmol/L. Conclusion: Icterus interferences have been defined for each analyte, observing differences compared to data provided by the manufacturer. The evidence indicates that each laboratory should evaluate icteric interferences to ensure the high quality of the delivered results, thus benefiting patient care.
Assuntos
Colesterol , Icterícia , Humanos , Soro , Bilirrubina , Creatinina , Creatina QuinaseRESUMO
Although many studies have been conducted on the use of median and transverse incisions in various surgeries in the field of human medicine, related studies in veterinary medicine are lacking. This study aimed to present treatment options for dogs requiring cholecystectomy by reporting the pros and cons of 121 cholecystectomies performed via transverse incision at our hospital over 10 years. In most included cases, nonelective cholecystectomy was performed in an unstable emergency situation. The perioperative mortality rate was 23.14%, which was not significantly different from that of cholecystectomy performed via the conventional midline approach. However, the overall operation time (46.24 ± 6.13 min; range 35-65 min) was shortened by securing an adequate surgical field of view. The transverse incision approach facilitates fast and accurate surgery without increasing the fatality rate in small-breed dogs, in whom securing an adequate surgical field of view is difficult. Thus, transverse incision should be actively considered in dogs undergoing cholecystectomy due to emergency conditions, such as bile leakage or biliary tract obstruction, since prolonged anesthesia can be burdensome. This study may improve cholecystectomy outcomes in small-breed dogs with difficult-to-secure surgical fields.
RESUMO
OBJECTIVES: Hemolysis, icterus, and lipemia (HIL) are common sources of endogenous interference in clinical laboratory testing. Defining the threshold of interference for immunoassays enables appropriate reporting of their results when they are affected by HIL. METHODS: Pools of residual patient serum samples were spiked with a known amount of interferent to create samples with varying concentrations of hemolysate, bilirubin, and Intralipid that mimicked the effects of endogenous HIL. Samples were analysed on the Alinity i analyser (Abbott Diagnostics) for more than 25 immunoassays. The average recovery relative to the non-spiked sample was calculated for each interference level and was compared to a predefined allowable bias. RESULTS: C-peptide, estradiol, serum folate, free T4, homocysteine, insulin, and vitamin B12 were found to be affected by hemolysis, at hemoglobin concentrations between 0.3 to 20 g/L. Immunoassays for BNP, estradiol, free T3, and homocysteine were affected by icterus at conjugated bilirubin concentrations between 50 to 1,044 µmol/L. BNP, serum folate, and homocysteine were affected by Intralipid with measured triglyceride concentrations between 0.8 to 10 mmol/L. Lastly, serological immunoassays for HIV and hepatitis A, B and C were also affected by interferences. CONCLUSIONS: Immunoassays are impacted by varying degrees of HIL interference. Some measurands, in the presence of interference, are affected in a manner not previously indicated. The data presented herein provide an independent evaluation of HIL thresholds and will be of aid to resource-limited clinical laboratories that are unable to internally verify endogenous interferences when implementing the Alinity i analyser.
Assuntos
Hiperlipidemias , Icterícia , Humanos , Hemólise , Hiperlipidemias/diagnóstico , Icterícia/diagnóstico , Imunoensaio/métodos , Bilirrubina , Estradiol , Ácido FólicoRESUMO
Prolonged icterus is an important and common problem in neonatology and accurate determination of the different bilirubin species, including differentiation between delta-bilirubin and mono- and di-conjugated bilirubin, is useful for diagnostic purposes. However, most bilirubin measurements routinely performed in the clinical laboratory are hampered by the lack of separation of the four bilirubin fractions (unconjugated bilirubin, mono-conjugated bilirubin, di-conjugated bilirubin, and delta-bilirubin). Herein, we propose a high-performance liquid chromatography-based method, independent of commercially available standards or reliable molar absorption coefficients, for the determination of bilirubin fractions in blood samples from icteric patients. The method is a robust and reliable candidate for a semi-automatized setup for measuring the various bilirubin fractions in a specialized laboratory handling samples from clinics with expertise in biliary disease.
Assuntos
Bilirrubina , Doenças da Vesícula Biliar , Humanos , Cromatografia Líquida de Alta Pressão/métodosRESUMO
Leptospirosis is a zoonosis with clinical manifestations caused by a pathogenic bacterium of the genus Leptospira. A high index of suspicion is required to make the diagnosis. The unusual constellation of symptoms makes the diagnosis of leptospirosis challenging and requires a comprehensive approach while treating the patient. This case illustrates the potential for severe complications of untreated leptospirosis and underlines the importance of a holistic approach to the diagnosis and treatment of patients with perplexing clinical presentations.
RESUMO
In this case report is discussed the diagnosis of papillary carcinoma in the case of a patient in whose age the occurrence of the disease is very rare. The patient underwent a series of non-invasive and invasive examinations, the results of which eventually led to a surgical solution of the suspected lesion (Wipples procedure). Histological examination of the resection confirmed mixed type ampular adenocarcinoma. In the context of this finding, the results of the examination, their information value, interpretation and mutual interaction are discussed. In the postoperative period, the patient suffered from gastrointestinal bleeding, subileum and poor postoperative healing. After hospitalization, the patient was transferred to oncology care and indicated for genetic testing.
Assuntos
Adenocarcinoma , Polipose Adenomatosa do Colo , Ampola Hepatopancreática , Neoplasias do Ducto Colédoco , Icterícia , Humanos , Ampola Hepatopancreática/patologia , Ampola Hepatopancreática/cirurgia , Polipose Adenomatosa do Colo/cirurgia , Neoplasias do Ducto Colédoco/diagnóstico , Neoplasias do Ducto Colédoco/patologia , Neoplasias do Ducto Colédoco/cirurgia , Adenocarcinoma/complicações , Adenocarcinoma/diagnóstico , Icterícia/patologiaRESUMO
Laparoscopic cholecystectomy (LC) is one of the most commonly performed general surgical procedures worldwide. Common bile duct (CBD) injuries are occasionally seen after this procedure and manifest as biliary peritonitis or bile collection; however, retroperitoneal bile leak is an extremely rare phenomenon manifesting as yellow discoloration of the abdominal wall, and a few cases are reported in the English literature. In this article, we describe one case of retroperitoneal bile leak that manifested as flank discoloration and its management.
RESUMO
Objective: Evaluate the technical performance of the pre-analytical hemolysis-icterus-lipemia (HIL) check module on the ACL-TOP-750. Methods: 8433 routine coagulation samples were evaluated for HIL, the presence of clotting and low sample volume by both visual inspection and the pre-analytical HIL check module on the ACL-TOP-750. Results: 7726 samples were in agreement with both methods and 707 were not consistent. 356 samples with low volume were identified by visual inspection and 920 by the instrument (2.7â mL threshold). Visual inspection identified 56 lipemic samples while 13 of those with moderate or high lipemia were identified by the instrument. Visual inspection identified 47 hemolyzed samples while 7 with moderate or high hemolysis were identified by the instrument. Both visual inspection and the instrument identified 36 icteric samples. For triglyceride concentration and bilirubin concentration, there was good correlation between the ACL-TOP-750 and the DXC800 biochemistry analyzer. Among 30 samples with varying amounts of clotting, 27 were discovered by visual inspection and 3 were discovered by the instrument. Conclusion: The pre-analytical check module on the ACL-TOP-750 improved the detection rate of samples below the target 2.7â mL volume, and the accuracy in detection of HIL. However, the automated method could not replace visual assessment of clotting in samples.
Assuntos
Hiperlipidemias , Icterícia , Testes de Coagulação Sanguínea/métodos , Hemólise , Hemostasia , HumanosRESUMO
Yellow lamb disease is an infrequent disease in sheep for which there is scant literature, and that has been reported in the US, Australia, New Zealand, South Africa and Europe, although anecdotal evidence indicates that it may have also been diagnosed in South America. The disease is produced by some strains of Clostridium perfringens type A that produce unusually high levels of alpha- toxin. Because C. perfringens type A is ubiquitous and is found in the intestine of most clinically healthy sheep, diagnosis of yellow lamb disease is challenging and requires quantitating the amount of this microorganism present in feces and/or intestinal content. Clinically, yellow lamb disease is characterized by depression, anemia, icterus and hemoglobinuria. Occasionally, sudden death may occur. Gross findings include generalized icterus, red urine in the bladder, enlarged, pale, and friable spleen, enlarged liver with an acinar pattern, and dark, swollen kidneys. Microscopically, yellow lamb disease is characterized by centrilobular necrosis of the liver, hemoglobinuria-associated acute tubular injury, splenic congestion, pulmonary congestion and edema. Although there are no vaccines specifically designed to prevent yellow lamb disease, several vaccines against the different types of C. perfringens may afford at least some level of protection against yellow lamb disease.
RESUMO
BACKGROUND: Serum quality is an important factor in the pre-analytical phase of laboratory analysis. Visual inspection of serum quality (including recognition of hemolysis, icterus, and lipemia) is widely used in clinical laboratories but is time-consuming, subjective, and prone to errors. METHODS: Deep learning models were trained using a dataset of 16,427 centrifuged blood images with known serum indices values (including hemolytic index, icteric index, and lipemic index) and their performance was evaluated by five-fold cross-validation. Models were developed for recognizing qualified, unqualified and image-interfered samples, predicting serum indices values, and finally composed into a deep learning-based system for the automatic assessment of serum quality. RESULTS: The area under the receiver operating characteristic curve (AUC) of the developed model for recognizing qualified, unqualified and image-interfered samples was 0.987, 0.983, and 0.999 respectively. As for subclassification of hemolysis, icterus, and lipemia, the AUCs were 0.989, 0.996, and 0.993. For serum indices and total bilirubin predictions, the Pearson's correlation coefficients (PCCs) of the developed model were 0.840, 0.963, 0.854, and 0.953 respectively. Moreover, 30.8% of serum indices tests were deemed unnecessary due to the preliminary application of the deep learning-based system. CONCLUSIONS: The deep learning-based system is suitable for the assessment of serum quality and holds the potential to be used as an accurate, efficient, and rarely interfered solution in clinical laboratories.