Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.039
Filtrar
1.
J Radiol Prot ; 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39142296

RESUMO

In response to the International Commission on Radiological Protection (ICRP), which lowered the lens equivalent dose limit, Japan lowered the lens dose limit from 150 mSv/year to 100 mSv/5 years and 50 mSv/year, with this new rule taking effect on April 1, 2021. DOSIRIS® is a dosimeter that can accurately measure lens dose. Herein, we investigated lens dose in interventional cardiology physicians one year before and after the reduction of the lens dose limit using a neck dosimeter and lens dosimeter measurements. With an increase in the number of cases, both personal dose equivalent at 0.07 mm [Hp(0.07), neck dosimeter] and personal dose equivalent at 3 mm depth [Hp(3), lens dosimeter] increased for most of the physicians. The Hp(3) of the lens considering the shielding effect of the Pb glasses using lens dosimeter exceeded 20 mSv/year for two of the 14 physicians. Protection from radiation dose will become even more important in the future, as these two physicians may experience radiation dose exceeding 100 mSv/5 years. The average dose per procedure increased, but not significantly. There was a strong correlation between the neck dosimeter and lens dosimeter scores, although there was no significant change before and after the lens dose limit was lowered. This correlation was particularly strong for physicians who primarily treated patients. As such, it is possible to infer accurate lens doses from neck doses in physicians who primarily perform diagnostics. However, it is desirable to use a dosimeter that can directly measure Hp(3) because of the high lens dose.

2.
J Clin Med ; 13(15)2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39124633

RESUMO

This review explores the transformative applications of augmented reality (AR) and mixed reality (MR) technologies in interventional cardiology. The integration of these cutting-edge systems offers unprecedented potential to enhance visualization, guidance, and outcomes during complex cardiac interventional procedures. This review examines four key domains: (1) medical AR/MR systems and technological foundations; (2) clinical applications across procedures like TAVI, PCI, and electrophysiology mapping; (3) ongoing technology development and validation efforts; and (4) educational and training applications for fostering essential skills. By providing an in-depth analysis of the benefits, challenges, and future directions, this work elucidates the paradigm shift catalyzed by AR and MR in advancing interventional cardiology practices. Through meticulous exploration of technological, clinical, and educational implications, this review underscores the pivotal role of these innovative technologies in optimizing procedural guidance, improving patient outcomes, and driving innovation in cardiovascular care.

3.
J Soc Cardiovasc Angiogr Interv ; 3(3Part B): 101302, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-39131213

RESUMO

Virtual reality technology provides an environment for advanced 3-dimensional visualization of complex cardiac anatomy from cross-sectional imaging. Visualization and case planning with procedural simulation is very relevant and likely critical for overall procedural success in complex congenital interventions. We report this case series demonstrating the use of virtual reality to conduct remote, collaborative interinstitutional consultations on computed tomography angiography prior to congenital percutaneous interventions.

4.
J Soc Cardiovasc Angiogr Interv ; 3(3Part B): 101301, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-39131218

RESUMO

Cardiac computed tomography angiography (CCTA) has become the gold standard for noninvasive anatomic assessment of the coronary arteries. With high positive predictive value and even higher negative predictive value, CCTA allows for rapid determination of the presence or absence of coronary plaque and triage of patients' need for further invasive evaluation and treatment. From an interventional cardiologist's perspective, CCTA (more so than stress testing) is helpful in determining the need for invasive therapy. In conjunction with functional assessments, the anatomic evaluation from CCTA mirrors the anatomical assessment of a coronary angiogram more than any other noninvasive assessment. This allows for catheter selection, percutaneous coronary intervention preplanning, as well as additional decision making before the patient has entered the catheterization laboratory. This manuscript explores some of the more recent developments in noninvasive coronary angiography and discusses the use and utility of CCTA from an interventional cardiologist's perspective.

6.
J Soc Cardiovasc Angiogr Interv ; 3(7): 101980, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39131996

RESUMO

The field of interventional cardiology (IC) has evolved dramatically over the past 40 years. Training and certification in IC have kept pace, with the development of accredited IC fellowship training programs, training statements, and subspecialty board certification. The application process, however, remained fragmented with lack of a universal process or time frame. In recent years, growing competition among training programs for the strongest candidates resulted in time-limited offers and high-pressure situations that disadvantaged candidates. A grassroots effort was recently undertaken by a Society for Cardiovascular Angiography & Interventions task force, to create equity in the system by establishing a national Match for IC fellowship. This manuscript explores the rationale, process, and implications of this endeavor.

7.
JACC Adv ; 3(7): 100981, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39130036

RESUMO

Shared decision-making (SDM) and multidisciplinary team-based care delivery are recommended across several cardiology clinical practice guidelines. However, evidence for benefit and guidance on implementation are limited. Informed consent, the use of patient decision aids, or the documentation of these elements for governmental or societal agencies may be conflated as SDM. SDM is a bidirectional exchange between experts: patients are the experts on their goals, values, and preferences, and clinicians provide their expertise on clinical factors. In this Expert Panel perspective, we review the current state of SDM in team-based cardiovascular care and propose best practice recommendations for multidisciplinary team implementation of SDM.

8.
Phys Med ; 124: 104487, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39084137

RESUMO

PURPOSE: To provide data on radiation exposure in paediatric interventional cardiology procedures, addressing the scarcity of valuable Local Diagnostic Reference Levels (LDRLs),established according to the standardized approach proposed by the Radiation Protection 185 report (RP185). METHODS: Paediatric catheterization procedures conducted at the University-Hospital of Padua from September 2019 to December 2022 were stratified by body weight (BW) classes and procedure type. LDRLs were calculated for groups with at least 20 patients as the 75th percentile of Kerma-Area Product (PKA) and Air Kerma at reference point (Ka,r) values. Kruskal-Wallis test was applied to evaluate differences in the dose-related quantities among BW groups for a selected procedure and among procedures for the same BW class. Results were compared with recent literature. RESULTS: A total of 838 procedures were analysed. LDRL were provided for five therapeutic procedures. The 75th percentile of PKA and Ka,r increases with weight, regardless procedure type. PKA and Ka,r are generally statistically different between BW groups, for both diagnostic and therapeutic procedures, and between different procedures at fixed weight group. Angioplasty and Right Ventricular Outflow Tract treatments (PVR) showed exposure values approximately doubled then other procedures. PKA/(BW·FT) is not statistically different among procedures except for Atrial Septal Defect (ASD) closures. LDRL values from this study are generally lower than the published ones. CONCLUSIONS: The study stands out as one of the few that presents a considerable number of LDRLs for weight categories and procedure types with a sample size of at least 20 patients per group, in agreement with RP185. PKA shows strong correlation with the product BW·FT.


Assuntos
Cardiologia , Humanos , Criança , Itália , Níveis de Referência de Diagnóstico , Pré-Escolar , Encaminhamento e Consulta , Lactente , Adolescente , Doses de Radiação , Feminino , Peso Corporal , Padrões de Referência , Masculino
9.
Am J Cardiol ; 227: 29-36, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38950689

RESUMO

Heart failure (HF) and moderate-to-severe mitral regurgitation (MR) with residual elevations in left atrial pressure (LAP) after MitraClip may remain symptomatic and experience subsequent HF readmissions. The V-Wave interatrial shunt system is a permanent interatrial septal implant that shunts blood from the left-to-right atrium and serves to continuously unload the left atrium. Although the V-Wave shunt has previously been studied in patients with HF, the safety and feasibility of its deployment at the time of the MitraClip procedure is unknown. The V-Wave Shunt MitraClip Study (NCT04729933) is an early feasibility study that aims to demonstrate the safety and efficacy of implantation of the V-Wave shunt device at the time of MitraClip procedure. Patients with moderate-to-severe secondary MR with left ventricular ejection fraction 20% to 50% and New York Heart Association functional class III/IV symptoms despite optimal medical therapy, residual mean LAP ≥20 mm Hg after MitraClip, and mean LAP-right atrial pressure difference ≥5 mm Hg are included. The primary safety end point is a composite outcome of all-cause death, stroke, myocardial infarction device embolization, cardiac tamponade, or device-related re-intervention or surgery at 30 days. Patients will be followed up to 5 years. Enrollment is ongoing, with 30-day results expected by the end of 2024. The V-Wave Shunt Mitraclip Study aims to demonstrate the safety and efficacy of the implantation of the V-Wave interatrial shunt device at the time of index MitraClip placement which may serve as an adjunctive method by which continuous left atrial unloading may be achieved.

11.
World J Cardiol ; 16(6): 363-369, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38993585

RESUMO

BACKGROUND: Inferior wall left ventricular aneurysms are rare, they develop after transmural myocardial infarction (MI) and may be associated with poorer prognosis. We present a unique case of a large aneurysm of the inferior wall complicated by ventricular tachycardia (VT) and requiring surgical resection and mitral valve replacement. CASE SUMMARY: A 59-year-old male was admitted for VT one month after he had a delayed presentation for an inferior ST-segment elevation MI and was discovered to have a large true inferior wall aneurysm on echocardiography and confirmed on coronary computed tomography (CT) angiography. Due to the sustained VT, concern for aneurysm expansion, and persistent heart failure symptoms, the patient was referred for surgical resection of the aneurysm with patch repair, mitral valve replacement, and automated implantable cardioverter defibrillator insertion with significant improvement in functional and clinical status. CONCLUSION: Inferior wall aneurysms are rare and require close monitoring to identify electrical or contractile sequelae. Coronary CT angiography can outline anatomic details and guide surgical intervention to ameliorate life-threatening complications and improve performance status.

12.
Diagnostics (Basel) ; 14(13)2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-39001283

RESUMO

The rapid advancement of artificial intelligence (AI) and robotics has led to significant progress in various medical fields including interventional radiology (IR). This review focuses on the research progress and applications of AI and robotics in IR, including deep learning (DL), machine learning (ML), and convolutional neural networks (CNNs) across specialties such as oncology, neurology, and cardiology, aiming to explore potential directions in future interventional treatments. To ensure the breadth and depth of this review, we implemented a systematic literature search strategy, selecting research published within the last five years. We conducted searches in databases such as PubMed and Google Scholar to find relevant literature. Special emphasis was placed on selecting large-scale studies to ensure the comprehensiveness and reliability of the results. This review summarizes the latest research directions and developments, ultimately analyzing their corresponding potential and limitations. It furnishes essential information and insights for researchers, clinicians, and policymakers, potentially propelling advancements and innovations within the domains of AI and IR. Finally, our findings indicate that although AI and robotics technologies are not yet widely applied in clinical settings, they are evolving across multiple aspects and are expected to significantly improve the processes and efficacy of interventional treatments.

13.
BMJ Case Rep ; 17(7)2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39043459

RESUMO

In the case of the degeneration of surgical aortic valve replacement (SAVR), the transcatheter aortic valve implantation (TAVI) has become the standard. However, these valves are also susceptible to deterioration. In such instances, a new TAVI implantation may be considered. We present the case of a patient with a SAVR who underwent two TAVI procedures, spaced 8 years apart. We discuss important practical aspects, including the risk of coronary obstruction and the final valve diameter.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/métodos , Falha de Prótese , Reoperação
14.
BMJ Case Rep ; 17(7)2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39043460

RESUMO

Cardiac fistulas present diagnostical and therapeutical challenges due to their variability in size, shape and pathway. Three-dimensional printing is increasingly used to provide a tactile representation that aids in preoperative planning and patient education. We present the case of a female in her 60s who developed a fistula between the left ventricle, right atrium and coronary sinus 2 years after bioprosthetic valve replacement. We used three-dimensional modelling to better understand her cardiac anatomy and optimise our surgical approach. She was discharged home without deficit following an uneventful postoperative course. Three-dimensional printing can improve patient care through tangible demonstration, preoperative planning and trainee education.


Assuntos
Impressão Tridimensional , Reoperação , Humanos , Feminino , Pessoa de Meia-Idade , Implante de Prótese de Valva Cardíaca , Ventrículos do Coração/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Átrios do Coração/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Próteses Valvulares Cardíacas , Bioprótese
15.
Heart Int ; 18(1): 5-8, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39006469

RESUMO

Hypertension (HTN) is one of the largest contributors to cardiovascular (CV) morbidity and mortality in the USA and is estimated to affect 47% of the US population; however, recent estimates suggest that over 40% continue to have uncontrolled HTN. In the past decade, multiple placebo-controlled randomized studies have shown the safety and efficacy of renal denervation as an adjunctive therapy, culminating in the recent approval of two devices by the US Food and Drug Administration (FDA). These devices use either radiofrequency or ultrasound energies to ablate the perivascular sympathetic nerves in the renal arteries and have been shown to reduce blood pressure. In this immediate post-FDA approval era, there are still multiple issues regarding the future of the technology in its applications and reimbursement landscapes.

16.
Int J Emerg Med ; 17(1): 87, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39010011

RESUMO

BACKGROUND: Blunt traumatic aortic injury (BTAI) is the second leading cause of death due to traumas in young patients. The primary presentation might be chest or interscapular pain, difficulty in breathing, and, in severe cases, hypotension. Considering the rapid deterioration of these patients' clinical conditions, prompt diagnosis and treatment initiation are crucial. In these injuries, the most involved parts of the aorta are the isthmus (distal to the left subclavian artery) and the descending part in the thorax. Therefore, the main diagnostic strategies include transthoracic echocardiography, CT angiography, and endovascular diagnostic approaches. Case presentation The patient was a 19-year-old male presenting with the symptoms of chest pain, dyspnea, and extremities excruciating pain after a car turnover. The initial evaluation showed no abnormal cardiovascular finding except bilateral hemothorax, addressed with chest tubes. Twelve hours later, when the patient was under observation for orthopedic surgeries, his chest pain and dyspnea started, and TTE and CTA showed a grade three descending aneurysm of the aorta. The patient was treated immediately with an endovascular procedure of stent implantation. A delayed debranching surgery was also performed, which resulted in desirable outcomes and uneventful follow-up. CONCLUSION: Although open thoracic surgery is the main and almost the only option for treating aneurysms of the aorta in hemodynamically unstable patients, the endovascular procedure has shown superior outcomes in selected patients with appropriate anatomy. Debranching surgery, which can be done simultaneously or with delay after the initial procedure, has proven protective against thromboembolic cerebral events. CLINICAL KEY POINT: Patients with an aneurysm of the aorta should be transported to a medical center with a multidisciplinary team for an urgent evaluation and treatment. The initial resuscitation and diagnosis are challenging, considering the fatal nature of these injuries, and the selection of the treatment is based on the patient's clinical condition and evaluated anatomy in cardiovascular imaging.

17.
J Clin Ultrasound ; 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39077985

RESUMO

In the dynamic field of interventional cardiology, significant strides have been made in reducing periprocedural complications. Echocardiography, particularly transesophageal echocardiography, plays a key role in ensuring the safety and success of structural heart interventions. Its real-time imaging capabilities allow for precise monitoring of device positioning, deployment, and procedural outcomes. By adhering to established imaging protocols and acquiring standard imaging planes, periprocedural echocardiography has become an essential tool for the successful performance of many structural heart interventions. In this manuscript, we present a series of unusual yet significant complications that we encountered during structural interventional procedures in our catheter laboratory. These complications, detected through echocardiography, underscore the critical role of imaging guidance in recognizing, and addressing unforeseen challenges, such as device malposition, thrombus formation in cardiac chambers during structural heart interventions, and cardiac tamponade during transcatheter mitral valve procedures. Through these cases, we highlight the effectiveness of transesophageal echocardiography in promptly identifying complications, allowing for timely intervention and resolution.

18.
Cureus ; 16(5): e61407, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38953063

RESUMO

This comprehensive review explores the transformative role of quantitative angiography in the landscape of cardiovascular medicine. Tracing the historical evolution of cardiovascular diagnostics, we emphasize the significance of angiography in diagnosis and treatment. The primary focus on quantitative angiography reveals its capacity to move beyond qualitative assessments, providing clinicians with precise measurements and objective parameters. This paradigm shift enhances diagnostic accuracy, promising far-reaching implications for the future of cardiovascular medicine. The ability to tailor interventions based on meticulous measurements optimizes therapeutic strategies and positions the field on the brink of a new era where personalized approaches become the norm. However, challenges such as image quality, radiation exposure, and interpretation variability persist, necessitating a collective call to action for continued research and development. As we confront these issues, collaborative efforts across disciplines are essential to refine existing technologies and usher in innovative solutions. This review concludes with a resounding call for ongoing research initiatives, large-scale clinical studies, and collective commitment to propel quantitative angiography into a universally accepted standard, ensuring its full realization in enhancing patient care and outcomes in cardiovascular medicine.

19.
J Radiol Prot ; 44(3)2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38959875

RESUMO

Background.Anecdotal reports are appearing in the scientific literature about cases of brain tumors in interventional physicians who are exposed to ionizing radiation. In response to this alarm, several designs of leaded caps have been made commercially available. However, the results reported on their efficacy are discordant.Objective.To synthesize, by means of a systematic review of the literature, the capacity of decreasing radiation levels conferred by radiation attenuating devices (RADs) at the cerebral level of interventional physicians.Methodology.A systematic review was performed including the following databases: MEDLINE, SCOPUS, EBSCO, Science Direct, Cochrane Controlled Trials Register (CENTRAL), WOS, WHO International Clinical Trials Register, Scielo and Google Scholar, considering original studies that evaluated the efficacy of RAD in experimental or clinical contexts from January 1990 to May 2023. Data selection and extraction were performed in triplicate, with a fourth author resolving discrepancies.Results.Twenty articles were included in the review from a total of 373 studies initially selected from the databases. From these, twelve studies were performed under clinical conditions encompassing 3801 fluoroscopically guided procedures, ten studies were performed under experimental conditions with phantoms, with a total of 88 procedures, four studies were performed using numerical calculations with a total of 63 procedures. The attenuation and effectiveness of provided by the caps analyzed in the present review varying from 12.3% to 99.9%, and 4.9% to 91% respectively.Conclusion.RAD were found to potentially provide radiation protection, but a high heterogeneity in the shielding afforded was found. This indicates the need for local assessment of cap efficiency according to the practice.


Assuntos
Exposição Ocupacional , Doses de Radiação , Proteção Radiológica , Humanos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle
20.
Am J Med ; 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38977147

RESUMO

Renal artery denervation has re-emerged as a potential therapeutic option for patients with hypertension, especially those resistant to conventional pharmacotherapy. This comprehensive review explores the importance of careful patient selection, procedural techniques, clinical efficacy, safety considerations, and future directions of renal artery denervation in hypertension management. Drawing upon a wide range of available evidence, this review aims to provide a thorough understanding of the procedure and its role in contemporary hypertension treatment paradigms.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA