Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Molecules ; 29(15)2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39125063

RESUMO

The advancement of traditional sample preparation techniques has brought about miniaturization systems designed to scale down conventional methods and advocate for environmentally friendly analytical approaches. Although often referred to as green analytical strategies, the effectiveness of these methods is intricately linked to the properties of the sorbent utilized. Moreover, to fully embrace implementing these methods, it is crucial to innovate and develop new sorbent or solid phases that enhance the adaptability of miniaturized techniques across various matrices and analytes. Graphene-based materials exhibit remarkable versatility and modification potential, making them ideal sorbents for miniaturized strategies due to their high surface area and functional groups. Their notable adsorption capability and alignment with green synthesis approaches, such as bio-based graphene materials, enable the use of less sorbent and the creation of biodegradable materials, enhancing their eco-friendly aspects towards green analytical practices. Therefore, this study provides an overview of different types of hybrid graphene-based materials as well as their applications in crucial miniaturized techniques, focusing on offline methodologies such as stir bar sorptive extraction (SBSE), microextraction by packed sorbent (MEPS), pipette-tip solid-phase extraction (PT-SPE), disposable pipette extraction (DPX), dispersive micro-solid-phase extraction (d-µ-SPE), and magnetic solid-phase extraction (MSPE).

2.
J Chromatogr A ; 1715: 464599, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38150874

RESUMO

Overweight and obesity are the causes of many diseases and have become global "epidemics". Research on natural active components with anti-adipogenesis effects in plants has aroused the interest of researchers. One of the most critical problems is establishing sample preparation and analytical techniques for quickly and selectively extracting and determining the active anti-adipogenesis components in complex plant matrices for developing new anti-adipogenic drugs. In this study, a new poly(deep eutectic solvents) surface imprinted graphene oxide composite (PDESs-MIP/GO) with high selectivity for phenolic acids was prepared using deep eutectic solvents as monomers and crosslinkers. A miniaturized centrifugation-accelerated pipette-tip matrix solid-phase dispersion method (CPT-MSPD) with PDESs-MIP/GO as adsorbent, coupled with high-performance liquid chromatography, was further developed for the rapid determination of anti-adipogenesis markers in Solidago decurrens Lour. (SDL). The established method was successfully used to determination anti-adipogenesis markers in SDL from different regions, with the advantages of accuracy (recoveries: 94.4 - 115.9 %, RSDs ≤ 9.8 %), speed (CPT-MSPD time: 11 min), selectivity (imprinting factor: ∼2.0), and economy (2 mg of adsorbent and 1 mL of solvents), which is in line with the current advanced principle of "3S+2A" in analytical chemistry.


Assuntos
Solventes Eutéticos Profundos , Grafite , Solidago , Extração em Fase Sólida/métodos , Solventes/química , Cromatografia Líquida de Alta Pressão
3.
Artigo em Inglês | MEDLINE | ID: mdl-36867997

RESUMO

Benznidazole is the main drug used in Chagas disease and its determination in plasma samples is useful in several situations. Hence, robust and accurate bioanalytical methods are needed. In this context, sample preparation deserves special attention, as it is the most error-prone, labor-intensive and time-consuming step. Microextraction by packed sorbent (MEPS) is a miniaturized technique, developed to minimize the use of hazardous solvents and sample amount. In this context, this study aimed to develop and validate a MEPS coupled to high performance liquid chromatography method for the analysis of benznidazole in human plasma. MEPS optimization was performed by a 24 full factorial experimental design, which resulted in about 25 % of recovery. The best condition was achieved when 500 µL of plasma,10 draw-eject cycles, sample volume drawn of 100 µL, and desorption with three times of 50 µL of acetonitrile were used. The chromatographic separation was performed with a C18 (150 × 4.5 mm, 5 µm) column. The mobile phase was composed of water:acetonitrile (60:40) at a flow rate of 1.0 mL min-1. The developed method was validated and proved to be selective, precise, accurate, robust and linear in the range from 0.5 to 6.0 µg mL-1. The method was applied to three healthy volunteers that made use of benznidazole tablets and showed to be adequate to assess this drug in plasma samples.


Assuntos
Microextração em Fase Sólida , Humanos , Cromatografia Líquida de Alta Pressão/métodos , Solventes/química , Microextração em Fase Sólida/métodos
4.
Food Chem ; 370: 131062, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-34537431

RESUMO

A simple method was developed to determine 14 endocrine-disrupting chemicals (EDCs) in bottled waters, based on dispersive micro-solid phase extraction (d-µ-SPE) and liquid chromatography-mass spectrometry (LC-MS). Extraction was optimized using 2 k-1 factorial and Doehlert experimental designs. Optimized conditions were 80 mg C18, 25 min extraction at 1000 rpm, and 6 min desorption time. Repeatability was below 17 % for all EDCs. LOD and LOQ varied from 1.60 ng L-1 (estradiol, E2) to 23.2 ng L-1 (dimethylphthalate, DMP) and from 5.33 ng L-1 (E2) to 77.3 ng L-1 (DMP). We found DMP and bisphenol A (BPA) in samples after the heat treatment. DMP was up to 58.7 µg L-1, while BPA was up to 1.34 µg L-1. Tolerance of daily intake (TDI) for DMP were 2.50-2.94 µg kg-1 day-1 (children) and 1.43-1.68 µg kg-1 day-1 (adults). TDI for BPA were 0.03-0.07 µg kg-1 day-1 (children) and 0.01-0.04 µg kg-1 day-1 (adults).


Assuntos
Água Potável , Disruptores Endócrinos , Águas Minerais , Poluentes Químicos da Água , Compostos Benzidrílicos/análise , Criança , Disruptores Endócrinos/análise , Humanos , Extração em Fase Sólida , Espectrometria de Massas em Tandem , Poluentes Químicos da Água/análise
5.
Molecules ; 26(9)2021 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-33923004

RESUMO

The wide range and complexity of cosmetic formulations currently available on the market poses a challenge from an analytical point of view. In addition, during cosmetics manufacture, impurities coming from raw materials or formed by reaction of different organic compounds present in the formulation may be present. Their identification is mandatory to assure product quality and consumer health. In this work, micro-matrix solid-phase dispersion (µMSPD) is proposed as a multi-target sample preparation strategy to analyze a wide number of unexpected families of compounds including polycyclic aromatic hydrocarbons (PAHs), pesticides, plasticizers, nitrosamines, alkylphenols (APs), and alkylphenol ethoxylates (APEOs). Analytical determination was performed by gas chromatography-mass spectrometry (GC-MS) for the determination of 51 target compounds in a single run, whereas liquid chromatography tandem mass spectrometry (LC-MS/MS) was employed for the analysis of six APs and APEOs. Both methodologies were successfully validated in terms of linearity, accuracy, and precision in leave-on and rinse-off cosmetics. Limits of detection (LODs) were calculated in the low ng g-1, showing their suitability to determine trace levels of impurities and banned compounds with different chemical natures, providing useful tools to cosmetic control laboratories and companies.


Assuntos
Cosméticos , Nitrosaminas/química , Hidrocarbonetos Policíclicos Aromáticos/química , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Limite de Detecção , Nitrosaminas/isolamento & purificação , Praguicidas/toxicidade , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Extração em Fase Sólida
6.
J Chromatogr A ; 1640: 461949, 2021 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-33556677

RESUMO

Analytical methods such as liquid chromatography (LC) and mass spectrometry (MS) are widely used techniques for the analyses of different classes of compounds. This is due to their highlighted capacity for separating and identifying components in complex matrices such food samples. However, in most cases, effective analysis of the target analyte becomes challenging due to the complexity of the sample, especially for quantification of trace concentrations. In this case, miniaturized sample preparation methods have been used as a strategy for analysis of complex matrices. This involves removing the interferents and concentrating the analytes in a sample. These methods combine simplicity and effectiveness and given their miniaturized scale, they are in accordance with green chemistry precepts. Besides, ambient mass spectrometry represents a new trend in fast and rapid analyses, especially for qualitative and screening analysis. However, for complex matrix analyses, sample preparation is still a difficult step and the miniaturized sample preparation techniques show great potential for an improved and widespread use of ambient mass spectrometry techniques. . This review aims to contribute as an overview of current miniaturized sample preparation techniques and ambient mass spectrometry methods as different approaches for selective and sensitive analysis of residues in food samples.


Assuntos
Análise de Alimentos/métodos , Espectrometria de Massas/métodos , Miniaturização/métodos , Cromatografia Líquida/métodos , Concentração de Íons de Hidrogênio , Microextração em Fase Líquida , Temperatura
7.
J Pharm Biomed Anal ; 190: 113486, 2020 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-32755807

RESUMO

A bioanalytical method for the determination of lumefantrine and its metabolite desbutyl-lumefantrine in plasma samples using microextraction by packed sorbent (MEPS) and high-performance liquid chromatography was developed and validated. A complete factorial planning and surface response approach were employed to optimize the extraction parameters sample volume, dilution, aspirated sample volume and extraction cycles. The method employed C18 MEPS sorbent and diazepam as internal standard (IS). Separation was performed on a Luna C18 column (250 mm × 4.6 mm, 5 µm) at 35 °C, with mobile phase composed of acetonitrile and 0.05 % trifluoroacetic acid (68:32, v/v), detection at 305 nm and injection volume of 25 µL. The developed method showed to be selective, precise, accurate and linear in the range of 50-5000 ng/mL for lumefantrine and desbutyl-lumefantrine. Using the optimized MEPS procedure, high recovery rates were obtained for both analytes and IS (92.2 %-99.0 %). The method was successfully applied for the determination of lumefantrine and its metabolite in human plasma samples after oral administration of lumefantrine tablets in healthy volunteers.


Assuntos
Cromatografia Líquida de Alta Pressão , Lumefantrina , Microextração em Fase Sólida , Humanos , Limite de Detecção , Lumefantrina/sangue , Reprodutibilidade dos Testes
8.
Mikrochim Acta ; 187(7): 387, 2020 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-32535659

RESUMO

A deep eutectic solvent functionalized graphene oxide composite adsorbent (DFG) was synthesized through reversible-addition fragmentation chain-transfer polymerization. The synthesized DFG had multiple adsorption interactions after covalent modification with a deep eutectic solvent (allyltriethylammonium bromide/ethylene glycol). Adsorption isotherms and kinetics studies of DFG indicate that the adsorption of hippuric acid (HA) and methylhippuric acid (MHA) was monolayer chemical adsorption. The comparison of DFG with commercial adsorbents demonstrates that the adsorption ability of DFG was superior. This was due to the multiple adsorption interactions of DFG for the three analytes (mainly π-interaction, hydrogen bonding, electrostatic adsorption, and hydrophobic interaction). The DFG adsorbent was applied to miniaturized pipette-tip solid-phase extraction (MPT-SPE), followed by high-performance liquid chromatography (HPLC) to determine biomarkers in urine for toluene and xylene exposure. The DFG-MPT-SPE-HPLC method required only 2.00 mg of DFG as adsorbent, 0.50 mL of washing solvent, and 0.40 mL of elution solvent to achieve a wide linear range (0.200-200 µg mL-1), high recoveries (90.9-99.1%), and high precision (RSD ≤ 6.3%). The proposed method was applied to determine HA and MHA in urine samples from occupational workers. Graphical abstract Deep eutectic solvent functionalized graphene oxide composite adsorbent for miniaturized pipette-tip solid-phase extraction of toluene and xylene exposure biomarkers in urine prior to their determination with HPLC-UV.


Assuntos
Grafite/química , Líquidos Iônicos/química , Tolueno/urina , Xilenos/urina , Adsorção , Biomarcadores/química , Biomarcadores/urina , Cromatografia Líquida de Alta Pressão , Grafite/síntese química , Humanos , Líquidos Iônicos/síntese química , Compostos de Amônio Quaternário/síntese química , Compostos de Amônio Quaternário/química , Extração em Fase Sólida/instrumentação , Extração em Fase Sólida/métodos , Solventes/síntese química , Solventes/química , Tolueno/química , Tolueno/isolamento & purificação , Xilenos/química , Xilenos/isolamento & purificação
9.
J Chromatogr A ; 1621: 461089, 2020 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-32362360

RESUMO

Given the increasing need for analyzing natural or contaminating compounds in complex food matrices in a simple and automated way, coupling miniaturized sample preparation techniques with chromatographic systems have become a growing field of research. In this regard, given the low extraction efficiency of conventional sorbent phases, the development of materials with enhanced extraction capabilities is of particular interest. Here we present several synthesized graphene-based materials supported on aminopropyl silica as sorbents for the extraction of xanthines. The synthesized materials were characterized by infrared spectroscopy and scanning electron microscopy. Aminopropyl silica coated with graphene oxide and functionalized with octadecylsilane/end-capped (SiGOC18ecap) showed the best performance for xanthines extraction. Hence, this material was employed as an in-tube solid phase microextraction (in-tube SPME) device coupled online with ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) and applied for the analysis of xanthines in roasted coffee samples. Extraction parameters and detection conditions were optimized. The method showed low limits of quantification (0.3-1.0 µg L-1), precision as relative standard deviation (RSD) values lower than 10%, recoveries between 73 and 109%, and pre-concentration factors from 5.6 to 7.2. Caffeine was determined in all ground roasted and instant coffee samples, in a wide range (0.9 to 36.8 mg g-1), and small amounts of theobromine and theophylline were also detected in some samples. This work demonstrated that functionalized graphene-based materials represent a promising new sorbent class for in-tube SPME, showing improved extraction capacity. The method was efficient, simple, and fast for the analysis of xanthines, demonstrating an excellent potential to be applied in other matrices.


Assuntos
Cromatografia Líquida/métodos , Café/química , Grafite/química , Dióxido de Silício/química , Microextração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Xantinas/análise , Adsorção , Cromatografia Líquida de Alta Pressão/métodos , Íons , Limite de Detecção , Xantinas/química
10.
J Sep Sci ; 43(1): 202-225, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31692234

RESUMO

Advances in the area of sample preparation are significant and have been growing significantly in recent years. This initial step of the analysis is essential and must be carried out properly, consisting of a complicated procedure with multiple stages. Consequently, it corresponds to a potential source of errors and will determine, at the end of the process, either a satisfactory result or a fail. One of the advances in this field includes the miniaturization of extraction techniques based on the conventional sample preparation procedures such as liquid-liquid extraction and solid-phase extraction. These modern techniques have gained prominence in the face of traditional methods since they minimize the consumption of organic solvents and the sample volume. As another feature, it is possible to reuse the sorbents, and its coupling to chromatographic systems might be automated. The review will emphasize the main techniques based on liquid-phase microextraction, as well as those based upon the use of sorbents. The first group includes currently popular techniques such as single drop microextraction, hollow fiber liquid-phase microextraction, and dispersive liquid-liquid microextraction. In the second group, solid-phase microextraction techniques such as in-tube solid-phase microextraction, stir bar sorptive extraction, dispersive solid-phase extraction, dispersive micro solid-phase microextraction, and microextraction by packed sorbent are highlighted. These approaches, in common, aim the determination of analytes at low concentrations in complex matrices. This article describes some characteristics, recent advances, and trends on miniaturized sample preparation techniques, as well as their current applications in food, environmental, and bioanalysis fields.


Assuntos
Métodos Analíticos de Preparação de Amostras/tendências , Poluição Ambiental/análise , Contaminação de Alimentos/análise , Microextração em Fase Líquida , Microextração em Fase Sólida , Adsorção , Monitoramento Ambiental , Manejo de Espécimes
11.
J Sep Sci ; 41(10): 2253-2260, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29457872

RESUMO

A simple method for the simultaneous determination of personal care product ingredients: galaxolide, tonalide, oxybenzone, 4-methylbenzyliden camphor, padimate-o, 2-ethylhexyl methoxycinnamate, octocrylene, triclosan, and methyl triclosan in lettuce by ultrasound-assisted extraction combined with solid-phase microextraction followed by gas chromatography with mass spectrometry was developed. Lettuce was directly extracted by ultrasound-assisted extraction with methanol, this extract was combined with water, extracted by solid-phase microextraction in immersion mode, and analyzed by gas chromatography with mass spectrometry. Good linear relationships (25-250 ng/g, R2  > 0.9702) and low detection limits (1.0-25 ng/g) were obtained for analytes along with acceptable precision for almost all analytes (RSDs < 20%). The validated method was applied for the determination of personal care product ingredients in commercial lettuce and lettuces grown in soil and irrigated with the analytes, identifying the target analytes in leaves and roots of the latter. This procedure is a miniaturized and environmentally friendly proposal which can be a useful tool for quality analysis in lettuce.


Assuntos
Cosméticos/análise , Contaminação de Alimentos/análise , Lactuca/química , Poluentes Químicos da Água/análise , Acrilatos/análise , Benzofenonas/análise , Benzopiranos/análise , Cânfora/análogos & derivados , Cânfora/análise , Cinamatos/análise , Cromatografia Gasosa-Espectrometria de Massas , Limite de Detecção , Espectrometria de Massas , Reprodutibilidade dos Testes , Solo/química , Microextração em Fase Sólida , Tetra-Hidronaftalenos/análise , Triclosan/análogos & derivados , Triclosan/análise , Ultrassom , para-Aminobenzoatos/análise
12.
Anal Chim Acta ; 804: 143-50, 2013 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-24267075

RESUMO

A rapid, green and effective miniaturized sample preparation and analytical technique, i.e. ionic liquids-assisted microwave distillation coupled with headspace single-drop microextraction (ILAMD-HS-SDME) followed by gas chromatography-mass spectrometry (GC-MS) was developed for the analysis of essential oil (EO) in Fructus forsythiae. In this work, ionic liquids (ILs) were not only used as the absorption medium of microwave irradiation but also as the destruction agent of plant cell walls. 1-Ethyl-3-methylimidazolium acetate ([C2mim]OAc) was chosen as the optimal ILs. Moreover, n-heptadecane (2.0 µL) was selected as the appropriate suspended solvent for the extraction and concentration of EO. Extraction conditions of the proposed method were optimized using the relative peak area of EO constituents as the index, and the optimal operational parameters were obtained as follows: irradiation power (300 W), sample mass (0.7 g), mass ratio of ILs to sample (2.4), temperature (78°C) and time (3.4 min). In comparison to previous reports, the proposed method was faster and required smaller sample amount but could equally monitor all EO constituents with no significant differences.


Assuntos
Medicamentos de Ervas Chinesas/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Micro-Ondas , Óleos Voláteis/análise , Microextração em Fase Líquida , Microscopia Eletrônica de Varredura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA