RESUMO
Objective Dysphagia is a common and disabling symptom in patients with myasthenia gravis (MG). Moreover, it is caused by muscle weakness or fatigability in the pharynx, swallowing, and respiration discoordination. The current study aimed to establish a novel method for evaluating swallowing difficulty in patients with MG. Methods The ventilation patterns and submental surface electromyography (sEMG) activity of the swallowing reflex were simultaneously recorded for 10 min during the continuous infusion of distilled water (150 mL/h) into the pharynx in 10 patients with MG and 22 healthy controls. Moreover, we assessed excessive expiratory flows, clusters of excessive expiratory flows, high-inspiratory flows, and prolonged EMG patterns. Results Patients with MG who presented with dysphagia had abnormal excessive expiratory flows, clusters of excessive expiratory flows, high inspiratory flows, and prolonged EMG patterns compared to healthy controls (all p <0.05). Among these parameters, the incidence of an excessive expiratory flow, cluster of excessive expiratory flows, and prolonged EMG pattern significantly improved after treatment (p <0.05). Conclusion Based on this study, the respiratory patterns and submental sEMG are likely to reflect the severity of pharyngeal muscle weakness/fatigability and thus can be used as a quantitative parameter for dysphagia in patients with MG.
RESUMO
Endoscopic nasopharyngectomy represents a significant intervention for recurrent nasopharyngeal carcinoma (NPC). Various surgical techniques, including transnasal and transoral approaches, are employed. However, the impact of these procedures on nasal airflow dynamics is not well understood. This computational fluid dynamics (CFD) study aimed to investigate alterations in nasal airflow and air conditioning following endoscopic nasopharyngectomy. A 55-year-old male patient with recurrent NPC was selected, whose CT data were utilized for image reconstruction. A preoperative model and two postoperative models, including the transnasal and transoral approach models, were established. The airflow patterns and various CFD parameters were analyzed. In the postoperative models, the high-speed airflow went along the soft palate and into the nasopharyngeal outlet, and there was the low-speed turbulence in the expanded nasopharyngeal cavity. Compared to the preoperative model, the postoperative models exhibited reductions in surface-to-volume ratio, nasal resistance, airflow velocity and proportion of high wall shear stress regions in nasopharynx. The changing trends of nasopharyngeal air temperature and humidity in the preoperative and transoral models were consistent. The heating and humidification efficiency decreased in the transnasal model compared to the transoral model. The endoscopic nasopharyngectomy for recurrent NPC affects the nasal airflow and warming and humidification function. The transoral approach has less influence on aerodynamics of the upper airway compared to the transnasal approach. From a CFD perspective, the endoscopic nasopharyngectomy does not increase the risk of postoperative complications, including the empty nose syndrome and the carotid blowout syndrome.
RESUMO
RELEVANCE: Nasal congestion is one of the most common complaints in otolaryngology practice and can significantly impact the quality of life for patients. Objective and subjective assessments provide different information, but objective assessment of nasal obstruction is crucial for accurate diagnosis and appropriate treatment. This review demonstrates that peak nasal inspiratory flow (PNIF) is a reproducible and reliable measure of objective nasal patency. It is inexpensive, easy to use, suitable for serial measurements, and can be applied to patients of different age groups. PNIF is recommended for use in every outpatient clinic that treats patients with nasal congestion. OBJECTIVE: To summarize the data on the application of PNIF in diagnosing conditions of the nasal airways. MATERIAL AND METHODS: Publications (articles and relevant abstracts) available in the PubMed and eLibrary databases were analyzed. CONCLUSION: PNIF offers an objective and non-invasive assessment of nasal airflow, aiding in diagnosis, therapy monitoring, and preoperative planning. Further research, standardization, and establishment of normative data will enhance the informative value of peak nasal inspiratory flow in assessing nasal obstruction.
Assuntos
Obstrução Nasal , Humanos , Obstrução Nasal/fisiopatologia , Obstrução Nasal/diagnóstico , Reprodutibilidade dos TestesRESUMO
OBJECTIVES: The aim of this study was to evaluate the effect of maxillary movements in orthognathic surgery on nasal airway volume change and its correlation with airflow and resistance. MATERIALS AND METHODS: This study included 25 patients (8 male, 17 female) with Class II (6 patients) or Class III (19 patients) malocclusion. All patients underwent Le Fort I and bilateral sagittal split ramus osteotomy. Nasal airflow and resistance were measured by using rhinomanometry and acoustic rhinometry pre and six months post-operatively. Nasal volume was measured using computed tomography before surgery and six months after surgery. RESULTS: Nasal volume increased in 10 out of 11 patients with CCW (counterclockwise) rotation and decreased in 1 patient while, nasal volume increased in 5 patients with CW (clockwise) rotation and decreased in 9 patients. Superior nasal airway volume increased significantly, while the effects on nasal flow and resistance were not significant. Additionally, no significant correlation was found between airway volume changes and variations in airflow and resistance. CONCLUSION: CCW rotation in orthognathic surgery patients significantly increased superior nasal airway volume but did not improve nasal airway flow and resistance.
Assuntos
Procedimentos Cirúrgicos Ortognáticos , Osteotomia de Le Fort , Osteotomia Sagital do Ramo Mandibular , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Adulto , Osteotomia de Le Fort/métodos , Procedimentos Cirúrgicos Ortognáticos/métodos , Osteotomia Sagital do Ramo Mandibular/métodos , Adulto Jovem , Imageamento Tridimensional , Má Oclusão Classe III de Angle/cirurgia , Má Oclusão Classe III de Angle/patologia , Rinomanometria , Resistência das Vias Respiratórias/fisiologia , Rinometria Acústica , Nariz/cirurgia , Nariz/patologia , Nariz/diagnóstico por imagem , Má Oclusão Classe II de Angle/cirurgia , Má Oclusão Classe II de Angle/diagnóstico , Má Oclusão Classe II de Angle/patologia , Respiração , Adolescente , Maxila/cirurgia , Maxila/diagnóstico por imagem , Maxila/patologiaRESUMO
BACKGROUND: The olfactory cleft (OC) is the most important anatomical site for the maintenance of olfactory function. Obstruction of airflow in the OC by various conditions, such as inflammation, leads to poor olfactory function. Therefore, it is important to increase OC airflow while performing endoscopic sinus surgery (ESS). However, no technique to increase airflow has yet been established. METHODS: We designed a superior turbinate lateralization (STL) procedure that displaces the entire ST bone laterally by eliminating the connection between the posterior ST and the anterior wall of the sphenoid sinus. The effect of the STL procedure was investigated in terms of anatomy and olfactory function. RESULTS: ESS with the STL procedure was performed on seven patients with chronic rhinosinusitis and nasal polyps. The cross-sectional area of the OC at 3 months postoperatively was significantly larger than that before ESS. In addition, the Open Essence test and questionnaires revealed significantly improvements in sense of smell. Airflow in the OC was significantly higher in STL procedure group than in the non-STL procedure group. CONCLUSION: The STL procedure enlarges the bony framework of the OC, and by increasing OC airflow, facilitates the transport of odorants to the olfactory epithelium, thereby improving olfactory perception.
Assuntos
Endoscopia , Pólipos Nasais , Olfato , Conchas Nasais , Humanos , Conchas Nasais/cirurgia , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Endoscopia/métodos , Olfato/fisiologia , Pólipos Nasais/cirurgia , Pólipos Nasais/fisiopatologia , Pólipos Nasais/complicações , Sinusite/cirurgia , Sinusite/fisiopatologia , Rinite/cirurgia , Rinite/fisiopatologia , Transtornos do Olfato/etiologia , Transtornos do Olfato/fisiopatologia , Transtornos do Olfato/cirurgia , Doença Crônica , Resultado do TratamentoRESUMO
Rhinomanometry is a pivotal diagnostic technique in rhinology, providing a quantitative assessment of nasal airflow and resistance. This review comprehensively examines the historical development, principles and clinical applications of rhinomanometry, emphasising its role in diagnosing nasal obstructions, preoperative evaluations and monitoring therapeutic outcomes. Recent advancements, including the integration with imaging technologies and the application of artificial intelligence (AI), have significantly enhanced the accuracy and utility of rhinomanometry. Despite facing challenges such as technical limitations and the need for standardisation, rhinomanometry remains an invaluable tool in both clinical and research settings. The review also explores future directions, highlighting the potential for device miniaturisation, telemedicine integration, personalised protocols and collaborative research efforts. These advancements will likely expand the accessibility, accuracy and clinical relevance of rhinomanometry, solidifying its importance in the ongoing evolution of rhinology practice.
RESUMO
Nasal airflow obstruction correlates with several ailments, such as higher patency, increased friction at the mucosal wall or the so-called Little's area, improper air conditioning, and snoring. Nasal dilators are frequently employed, mainly due to their ease of access and use, combined with their non-permanent and non-surgical nature. Their overall efficacy, however, has not been clearly demonstrated so far, with some studies reporting conflicting outcomes, mainly because being based on subjective evaluations. This study employs Computational Fluid Dynamics simulations to analyze the flow inside a real nose, performs an objective assessment of a nasal dilator's effect in terms of airflow and air conditioning, reporting flow paths, friction levels, heat and water fluxes and detailed temperature and humidity distributions. Coincidentally, the studied nose presents a septal deviation, with one nostril being wider than the other. The tubes of the dilator used in both nostrils are identical, as with any standard commercial dilator. Consequently, the dilator widens one nostril, as intended, but results in an obstruction in the other. This allows simultaneously addressing two situations, the nominal function of the dilator, as well as an off-design case. Results indicate a 24 % increase in nasal patency in the design situation. The effect, however, is limited, as quantified by appropriate measures, such as the flow-generated friction at the nose surfaces and the temperature fluxes. Hence, the effect of such a dilator in nominal conditions is perhaps not as large as might be hoped. In the off-design situation, nasal resistance increases by 62 %, an undesirable effect, illustrating the consequences of using an inappropriate dilator.
Assuntos
Simulação por Computador , Humanos , Dilatação/instrumentação , Modelos Biológicos , Obstrução Nasal/fisiopatologia , Cavidade Nasal/fisiologia , Hidrodinâmica , Nariz/fisiologiaRESUMO
Face cups form a vital component of breathing, assisting with devices that aid in artificial breathing for neonates. This study aims to evaluate the flow parameters in the nasal cavity for two different types of face cups. The neonatal nasal cavity model was developed from CT scans using MIMICS 21.0. Two face cups, one hemispherical and the other anatomical shaped cups are developed around the nasal cavity and the airflow is simulated using ANSYS 2021 R2. Results are compared with a nasal-only model. At the nasal valve region, the highest velocity is seen for the nasal-only model which is 16.3% higher than that of the hemispherical face cup and 15.2% superior to the anatomical-shaped face cup. In addition, the decrease in pressure across the nasal-only model is 7.4 and 6.6% below that of the hemispherical cup and anatomical cup masks. The nasal resistance values across the nasal cavity are the lowest for the nasal-only model, 7.7 and 6.7% lower respectively than the hemispherical and anatomical-shaped cups. There were very minor changes in the flow parameters such as velocity, pressure and wall shear stress when comparing the hemispherical and anatomic-shaped masks for the airflow inside the nasal cavity.
RESUMO
This study aimed to explore the variability in nasal airflow patterns among different sexes and populations using computational fluid dynamics (CFD). We focused on evaluating the universality and applicability of dimensionless parameters R (bilateral nasal resistance) and Ï (nasal flow asymmetry), initially established in a Caucasian Spanish cohort, across a broader spectrum of human populations to assess normal breathing function in healthy airways. In this retrospective study, CT scans from Cambodia (20 males, 20 females), Russia (20 males, 18 females), and Spain (19 males, 19 females) were analyzed. A standardized CFD workflow was implemented to calculate R-Ï parameters from these scans. Statistical analyses were conducted to assess and compare these parameters across different sexes and populations, emphasizing their distribution and variances. Our results indicated no significant sex-based differences in the R parameter across the populations. However, moderate sexual dimorphism in the Ï parameter was observed in the Cambodian group. Notably, no geographical differences were found in either R or Ï parameters, suggesting consistent nasal airflow characteristics across the diverse human groups studied. The study also emphasized the importance of using dimensionless variables to effectively analyze the relationships between form and function in nasal airflow. The observed consistency of R-Ï parameters across various populations highlights their potential as reliable indicators in both medical practice and further CFD research, particularly in diverse human populations. Our findings suggest the potential applicability of dimensionless CFD parameters in analyzing nasal airflow, highlighting their utility across diverse demographic and geographic contexts. This research advances our understanding of nasal airflow dynamics and underscores the need for additional studies to validate these parameters in broader population cohorts. The approach of employing dimensionless parameters paves the way for future research that eliminates confounding size effects, enabling more accurate comparisons across different populations and sexes. The implications of this study are significant for the advancement of personalized medicine and the development of diagnostic tools that accommodate individual variations in nasal airflow.
Assuntos
Hidrodinâmica , Humanos , Masculino , Feminino , Adulto , Resistência das Vias Respiratórias/fisiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Pessoa de Meia-Idade , Cavidade Nasal/fisiologia , Cavidade Nasal/diagnóstico por imagem , Cavidade Nasal/anatomia & histologia , Simulação por Computador , Camboja , EspanhaRESUMO
OBJECTIVE: Mucosal decongestion with nasal sprays is a common treatment for nasal airway obstruction. However, the impact of mucosal decongestion on nasal aerodynamics and the physiological mechanism of nasal airflow sensation are incompletely understood. The objective of this study is to compare nasal airflow patterns in nasal airway obstruction (NAO) patients with and without mucosal decongestion and nondecongested healthy subjects. STUDY DESIGN: Cross-sectional study of a convenience sample. SETTING: Academic tertiary medical center. METHODS: Forty-five subjects were studied (15 nondecongested healthy subjects, 15 nondecongested NAO patients, and 15 decongested NAO patients). Three-dimensional models of the nasal anatomy were created from computed tomography scans. Steady-state simulations of airflow and heat transfer were conducted at 15 L/min inhalation rate using computational fluid dynamics. RESULTS: In the narrow side of the nose, unilateral nasal resistance was similar in decongested NAO patients and nondecongested healthy subjects, but substantially higher in nondecongested NAO patients. The vertical airflow distribution within the nasal cavity (inferior vs middle vs superior) was also similar in decongested NAO patients and nondecongested healthy subjects, but nondecongested NAO patients had substantially less middle airflow. Mucosal cooling, quantified by the surface area where heat flux exceeds 50 W/m2, was significantly higher in decongested NAO patients than in nondecongested NAO patients. CONCLUSION: This pilot study suggests that mucosal decongestion improves objective measures of nasal airflow, which is consistent with improved subjective sensation of nasal patency after decongestion.
Assuntos
Descongestionantes Nasais , Mucosa Nasal , Obstrução Nasal , Humanos , Projetos Piloto , Obstrução Nasal/fisiopatologia , Masculino , Feminino , Descongestionantes Nasais/administração & dosagem , Estudos Transversais , Adulto , Mucosa Nasal/fisiologia , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Sprays Nasais , Resistência das Vias Respiratórias/fisiologiaRESUMO
INTRODUCTION: Rhinofiller is an aesthetic medical technique that can significantly enhance facial aesthetics by employing hyaluronic acid infiltration. The aim of this study is to review the impact of aesthetic rhinofiller on nasal airflow. METHODS: This is a retrospective review of 63 consecutive patients. The evaluation of the change in nasal respiratory flow was performed subjectively using a Likert questionnaire and objectively using a rhinomanometer, which enabled active anterior rhinomanometry (AAR). Data were collected at pre-intervention, post-intervention, and at 6-month follow-up. RESULTS: Among the 63 patients, the questionnaire responses resulted statistically significant both after the treatment and at the 6-month follow-up (p=0.00001). A statistically significant improvement was also observed at the rhinomanometric evaluation between pre-intervention and post-intervention (p=0.006 at 74 Pa, p=0.002 at 100 Pa, and p=0.001 at 150 Pa) and at the 6-month follow-up (p=0.008 at 74 Pa, p=0.003 at 100 Pa, and p=0.002 at 150 Pa). Differences between results were established with a Student's t-test. All p-values were two-tailed, and a value < 0.05 was considered significant. CONCLUSIONS: Rhinofiller can be a valuable aid in enhancing both nasal airflow and facial aesthetics. Based on our experience, it resulted in an immediate post-operative improvement in nasal airflow that remains stable in the subsequent 6 months. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 . IV: Non-Surgical Procedures.
Assuntos
Estética , Ácido Hialurônico , Rinomanometria , Humanos , Estudos Retrospectivos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Ácido Hialurônico/administração & dosagem , Resultado do Tratamento , Inquéritos e Questionários , Satisfação do Paciente/estatística & dados numéricos , Estudos de Coortes , Adulto Jovem , Rinoplastia/métodos , SeguimentosRESUMO
Computational rhinology is a specialized branch of biomechanics leveraging engineering techniques for mathematical modelling and simulation to complement the medical field of rhinology. Computational rhinology has already contributed significantly to advancing our understanding of the nasal function, including airflow patterns, mucosal cooling, particle deposition, and drug delivery, and is foreseen as a crucial element in, e.g., the development of virtual surgery as a clinical, patient-specific decision support tool. The current paper delves into the field of computational rhinology from a nasal airflow perspective, highlighting the use of computational fluid dynamics to enhance diagnostics and treatment of breathing disorders. This paper consists of three distinct parts-an introduction to and review of the field of computational rhinology, a review of the published literature on in vitro and in silico studies of nasal airflow, and the presentation and analysis of previously unpublished high-fidelity CFD simulation data of in silico rhinomanometry. While the two first parts of this paper summarize the current status and challenges in the application of computational tools in rhinology, the last part addresses the gross disagreement commonly observed when comparing in silico and in vivo rhinomanometry results. It is concluded that this discrepancy cannot readily be explained by CFD model deficiencies caused by poor choice of turbulence model, insufficient spatial or temporal resolution, or neglecting transient effects. Hence, alternative explanations such as nasal cavity compliance or drag effects due to nasal hair should be investigated.
RESUMO
Objectives: This study aims to delineate the specific impact of using computational fluid dynamics (CFD) and 3D virtual surgery techniques in otolaryngology surgery, focusing on their roles in enhancing the precision of nasal surgery and optimizing future patient outcomes. The central objective was to assess whether these advanced technologies could reduce variability in surgical approaches and decision-making among specialists, thereby improving the consistency and efficacy of patient care in cases of nasal obstruction. Methods and results: Our methodology involved a detailed analysis of pre- and post-operative scenarios using CFD feedback. Six otolaryngologists participated, employing virtual surgery techniques on two patients with diagnosed nasal obstruction. The CFD analysis focused on quantifying key airflow parameters: right nasal flow rate (QR), left nasal flow rate (QL), flow symmetry (Ф), and bilateral nasal resistance (R). These parameters were meticulously compared before and after the application of CFD feedback to evaluate changes in surgical planning and outcomes. Quantitative analysis revealed a notable decrease in the standard deviation of the measured parameters among the specialists post-CFD feedback, indicating reduced variability in surgical approaches. Specifically, for Patient #1 the standard deviation for QR values dropped from 0.694 L/min to 0.602 L/min, and for QL values from 0.676 L/min to 0.584 L/min, and for Patient #2, the standard deviation for QR values decreased from 2.204 L/min to 0.958 L/min, and for QL values from 2.295 L/min to 1.014 L/min. Moreover, the variability range, represented by the differences between the maximum and minimum values for Ф and R, diminished significantly. Post-operative average values for all parameters showed a convergence towards ideal basal levels, suggesting a more uniform and effective surgical strategy across different surgeons. Conclusions: Both integration of CFD and 3D virtual surgery techniques in otolaryngology can substantially reduce variability in surgical planning and decision-making, ultimately leading to improved patient outcomes. These advanced tools have the potential to standardize the diagnosis and treatment of nasal pathologies, contributing to more effective and consistent care. Future research in this area should focus on larger patient cohorts and further exploration of the potential benefits and applications of CFD and virtual surgery in otolaryngology.
RESUMO
This study aims to evaluate the histological changes in the nasal mucosa post Tracheostomy. A prospective observational study was done on 30 patients undergoing Tracheostomy after obtaining written informed consent from patients/legally accepted representatives. Prior to Tracheostomy, anterior rhinoscopy was done, and findings were noted; nasal mucosal biopsy was obtained from the inferior turbinate. The patients enrolled were followed up for four weeks, and in the patients still having Tracheostomy, repeat inferior turbinate biopsies were taken and compared. Statistically significant atrophy of lining epithelium was seen in 80% of the subjects, i.e., pseudostratified lining epithelium at Baseline with multilayered appearance changed to a single layer of flattened cells at follow-up. There was also a marked reduction in the number of seromucinous glands in the stroma at follow-up in 80% of the subjects. Additionally, fibrosis in the stroma was noted in 43.3% of subjects at follow-up. The results from this study indicate that Tracheostomy, likely as a result of nasal airflow deprivation, brings about significant changes in the microanatomy of the nasal airway. The extent of this causation and its implication in nasal pathology must be studied in larger populations with extended follow-up periods.
RESUMO
Objective: Total laryngectomy (TL) patients are good models in which to evaluate the effects of nasal airflow cessation on the sinonasal tract. Here, we evaluated changes in sinonasal structures and association with sinus opacification in the computed tomography (CT) images 3 years post-TL. Methods: Patients who underwent TL from 2005 to 2017 in a teaching academic center were reviewed retrospectively. Patients with a final follow-up CT taken less than 3 years after TL, tracheoesophageal puncture, inadequate CT image, or history of sinonasal surgery were excluded. The control group included patients who underwent a partial laryngectomy or hypopharyngectomy without requiring a tracheotomy for more than a month. Altogether, 45 TL patients and 38 controls were selected. The volume of all four paranasal sinuses, inferior turbinate soft tissue volume (ITSTV), maxillary sinus natural ostium (MSNO) mucosal width, and Lund-Mackay scores (LMS) were measured on preoperative and postoperative CT scans. Results: The mean duration between surgery and the final CT scan was 6.3 ± 2.4 and 5.5 ± 2.3 years for the TL and control groups, respectively. Neither group showed significant changes in the four paranasal sinuses' volume or MSNO mucosa width. The ITSTV decreased significantly, from 4.6 ± 1.3 to 2.8 ± 1.1 mL (p < .001), in the TL group, regardless of the presence of nasal septal deviation, showing ITSTV reduction on both concave and convex sides. By contrast, the control group showed no significant changes in ITSTV. Postoperative LMS changes in both groups were insignificant. The number of patients with LMS aggravation or alleviation was the same in both groups, regardless of preoperative sinus opacification. Conclusions: Paranasal sinus structures and sinus opacification are not affected significantly by nasal airflow cessation; however, the inferior turbinate mucosa is affected by long-term discontinuation of nasal airflow. Level of Evidence: 4 (case-control study).
RESUMO
Nasal congestion is a common issue stemming from various factors such as allergies and anatomical variations. Allergic rhinitis frequently leads to nasal congestion. The pathophysiology involves inflammation, swelling, and mucus production in the nasal mucosa. Multiple treatments are available, including oral phenylephrine, an over-the-counter or prescription option. However, the effectiveness and safety of phenylephrine have been subjects of debate. This systematic review aims to provide an updated perspective on the efficacy of oral phenylephrine versus placebo in addressing nasal congestion in adults. We conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines, a systematic review involving searches on PubMed, Cochrane, and Scopus databases. Inclusion/exclusion criteria were defined to identify high-quality studies. The focus was on randomized controlled trials (RCTs) and case-control studies published in English between 1998 and 2023, involving adult populations. The interventions compared oral phenylephrine with placebo or standard care, with outcomes centering on changes in nasal congestion symptoms and nasal airway resistance. We identified four articles that met the criteria. These studies exhibited varied designs and populations. The findings consistently indicated that phenylephrine was not more effective than a placebo in relieving nasal congestion. This systematic review demonstrates that oral phenylephrine did not offer substantial relief from nasal congestion compared to a placebo in adults. The studies featured diverse designs, yet the prevailing conclusion was that phenylephrine's efficacy was limited. Safety assessments showed no life-threatening adverse events, with common side effects including headaches and mild discomfort. In summary, this systematic review indicates that oral phenylephrine is not significantly more effective than a placebo in alleviating nasal congestion in adults. Clinicians should explore alternative treatment options, considering the review's limitations. Additional research may be needed to clarify the role of oral phenylephrine in managing nasal congestion.
RESUMO
Neurologic outcome from out-of-hospital pediatric cardiac arrest remains poor. Although therapeutic hypothermia has been attempted in this patient population, a beneficial effect has yet to be demonstrated, possibly because of the delay in achieving target temperature. To minimize this delay, we developed a simple technique of transnasal cooling. Air at ambient temperature is passed through standard nasal cannula with an open mouth to produce evaporative cooling of the nasal passages. We evaluated efficacy of brain cooling with different airflows in different size piglets. Brain temperature decreased by 3°C within 25 minutes with nasal airflow rates of 16, 32, and 16 L/min in 1.8-, 4-, and 15-kg piglets, respectively, whereas rectal temperature lagged brain temperature. No substantial spatial temperature gradients were seen along the neuroaxis, suggesting that heat transfer is via blood convection. The evaporative cooling did not reduce nasal turbinate blood flow or sagittal sinus oxygenation. The rapid and selective brain cooling indicates a high humidifying capacity of the nasal turbinates is present early in life. Because of its simplicity, portability, and low cost, transnasal cooling potentially could be deployed in the field for early initiation of brain cooling prior to maintenance with standard surface cooling after pediatric cardiac arrest.
Assuntos
Reanimação Cardiopulmonar , Hipotermia Induzida , Parada Cardíaca Extra-Hospitalar , Humanos , Animais , Criança , Suínos , Hipotermia Induzida/métodos , Temperatura Baixa , Temperatura Corporal/fisiologia , Encéfalo , Reanimação Cardiopulmonar/métodosRESUMO
PURPOSE: To determine the relationship of chemosensory screening and nasal airflow tests among the same set of participants, and to determine other factors that are related to the outcomes of these tests. METHODS: Participants had no chemosensory complaints. Structured medical history was taken. Participants underwent 5 screening tests: q-sticks (orthonasal olfaction), q-powders (retronasal olfaction), trigeminal lateralization test, taste sprays, and peak nasal inspiratory flow (PNIF). Ratings of smell/taste ability and nasal airflow were obtained using visual analogue scales (VAS). Composite sinusitis symptoms and significance of olfaction questionnaire scores were also determined. RESULTS: Four hundred participants were included in the study, 156 men, 244 women; aged 18-82 years (mean: 46). The q-powders and taste spray scores were weakly positively correlated with all the other chemosensory tests and PNIF. However, chemosensory test scores were not correlated with VAS, composite sinusitis symptoms, and significance of olfaction questionnaire scores. Various tests showed significant decrease starting at specific ages (in years, PNIF and trigeminal lateralization: 40, q-powders: 60, and q-sticks: 70). CONCLUSION: Chemosensory screening tests and self-rated chemosensory function showed no correlation in participants without chemosensory complaints. In addition, gustatory function appeared to be correlated with olfactory and trigeminal function but also with nasal airflow, and nasal airflow was related not only to olfactory but also to trigeminal and taste function. Over all, the results suggest that chemosensory functions (orthonasal olfactory, trigeminal, retronasal olfactory, gustatory) and nasal airflow are correlated with each other, which we propose may be possibly mediated, at least in part, through central nervous system interactions.
Assuntos
Transtornos do Olfato , Sinusite , Masculino , Humanos , Feminino , Transtornos do Olfato/diagnóstico , Transtornos do Olfato/etiologia , Pós , Nariz , Olfato/fisiologiaRESUMO
OBJECTIVES: Recent evidence suggests that detection of nasal mucosal temperature, rather than direct airflow detection, is the primary determinant of subjective nasal patency. This study examines the role of nasal mucosal temperature in the perception of nasal patency using in vivo and computational fluid dynamics (CFD) measurements. METHODS: Healthy adult participants completed Nasal Obstruction Symptom Evaluation (NOSE) and Visual Analogue Scale (VAS) questionnaires. A temperature probe measured nasal mucosal temperature at the vestibule, inferior turbinate, middle turbinate, and nasopharynx bilaterally. Participants underwent a CT scan, used to create a 3D nasal anatomy model to perform CFD analysis of nasal mucosal and inspired air temperature and heat flux along with mucosal surface area where heat flux >50 W/m2 (SAHF50). RESULTS: Eleven participants with a median age of 27 (IQR 24; 48) were recruited. Probe-measured temperature values correlated strongly with CFD-derived values (r = 0.87, p < 0.05). Correlations were seen anteriorly in the vestibule and inferior turbinate regions between nasal mucosal temperature and unilateral VAS (r = 0.42-0.46; p < 0.05), between SAHF50 and unilateral VAS (r = -0.31 to -0.36; p < 0.05) and between nasal mucosal temperature and SAHF50 (r = -0.37 to -0.41; p < 0.05). Subjects with high patency (VAS ≤10) had increased heat flux anteriorly compared with lower patency subjects (VAS >10; p < 0.05). CONCLUSION: Lower nasal mucosal temperature and higher heat flux within the anterior nasal cavity correlates with a perception of improved unilateral nasal patency in healthy individuals. LEVEL OF EVIDENCE: 4 Laryngoscope, 133:1328-1335, 2023.