Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 204: 111126, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38039828

RESUMO

The pulsed neutron source (PNS) technique was used to determine the prompt neutron decay constant for two different lattice pitches in the HWZPR heavy water zero power reactor. The results were compared to the variance-to-mean ratio (VTM) method. The neutron mean generation time was also calculated for both pitches, and the results were compared to previous Monte Carlo calculations. The findings of this research can be used as a benchmark nuclear codes to validate kinetic parameters.

2.
Artigo em Inglês | MEDLINE | ID: mdl-31092963

RESUMO

Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electronantineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for escaping back through the entrance after backscattering. The design, construction, calibration, and performance of the spectrometer are discussed.

3.
Nucl Instrum Methods Phys Res A ; 701(100): 254-261, 2013 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-23576831

RESUMO

We propose a new type of momentum spectrometer, which uses the R×B drift effect to disperse the charged particles in a uniformly curved magnetic field, and measures the particles with large phase space acceptance and high resolution. This kind of R×B spectrometer is designed for the momentum analyses of the decay electrons and protons in the PERC (Proton and Electron Radiation Channel) beam station, which provides a strong magnetic field to guide the charged particles in the instrument. Instead of eliminating the guiding field, the R×B spectrometer evolves the field gradually to the analysing field, and the charged particles can be adiabatically transported during the dispersion and detection. The drifts of the particles have similar properties as their dispersion in the normal magnetic spectrometer. Besides, the R×B spectrometer is especially ideal for the measurements of particles with low momenta and large incident angles. We present a design of the R×B spectrometer, which can be used in PERC. For the particles with solid angle smaller than 88 msr, the maximum aberration is below 10-4. The resolution of the momentum spectra can reach 14.4 keV/c, if the particle position measurements have a resolution of 1 mm.

4.
J Res Natl Inst Stand Technol ; 110(4): 395-400, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308156

RESUMO

The coefficient a 0 has been derived from a measurement of the integral spectrum of recoil protons stored in a quasi-Penning trap with inhomogeneous magnetic field and adiabatic focusing onto an electro-static mirror of potential variable in 10 V steps between 0 V and 850 V. Correction for incomplete transfer of energy from transverse to longitudinal degrees of freedom, and the violation of the adiabatic conditions on reflection at the mirror, is carried out by alternately measuring the spectrum at trapping times of 1 ms and 2 ms. The results a 0 = -0.1054 ± 0.0055 and |λ | = 1.271 ± 0.018 are comparable in precision with existing measurements of a 0.

5.
J Res Natl Inst Stand Technol ; 110(4): 401-5, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308157

RESUMO

Currently, the beta-neutrino asymmetry has the largest uncertainty (4 %) of the neutron decay angular correlations. Without requiring polarimetry this decay parameter can be used to measure λ (ga/gv ), test Cabibbo-Kobayashi-Maskawa (CKM) unitarity limit scalar and tensor currents, and search for Charged Vector Current (CVC) violation. We propose to measure the beta-neutrino asymmetry coeffcient, a, using time-of-flight for the recoil protons. We hope to achieve a systematic uncertainty of σa / a ≈ 1.0 %. After tests at Indiana University's Low Energy Neutron Source (LENS), the apparatus will be moved to the National Institute of Standards and Technology (NIST) where the measurement can achieve a statistical uncertainty of 1 % to 2 % in about 200 beam days.

6.
J Res Natl Inst Stand Technol ; 110(4): 421-5, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308161

RESUMO

Beta decay of the neutron into a proton, electron, and electron antineutrino is occasionally accompanied by the emission of a photon. Despite decades of detailed experimental studies of neutron beta-decay, this rare branch of a fundamental weak decay has never been observed. An experiment to study the radiative beta-decay of the neutron is currently being developed for the NG-6 fundamental physics endstation at the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR). The experiment will make use of the existing apparatus for the NIST proton-trap lifetime experiment, which can provide substantial background reduction by providing an electron-proton coincidence trigger. Tests and design of a detector for gamma-rays in the 10 keV to 200 keV range are under development. The need for a large solid-angle gamma-ray detector that can operate in a strong magnetic field and at low temperature has led us to consider scintillating crystals in conjunction with avalanche photodiodes. The motivation and experimental technique will be discussed.

7.
J Res Natl Inst Stand Technol ; 110(4): 431-6, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308163

RESUMO

A new method of measuring the electron-antineutrino angular correlation coefficient, little "a", from neutron decay-to be performed at the National Institute of Standards and Technology-will require an electron spectrometer that strongly suppresses backscattered electrons. A prototype consisting of six trapezoidal veto detectors arranged around a plastic scintillator has been tested with an electron beam produced by a Van de Graaff accelerator. The results of this test and its implications for the little "a" measurement are discussed.

8.
J Res Natl Inst Stand Technol ; 110(4): 415-20, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308160

RESUMO

Results of the first experiment to search for the radiative decay mode of the free neutron are reported. The γ-spectrum was studied in the energy region from 35 keV to 100 keV in six Cs(Tl) scintillators, each set at an angle of 35° to, and shielded from, a central plastic scintillator electron detector. Triple coincidences were recorded with recoil protons detected in a micro-channel plate. A limit for the branching ratio BR < 6.9 × 10(-3) (90 % confidence level) was obtained, which is greater that the theoretical prediction by not more than a few tenths of a percent.

9.
J Res Natl Inst Stand Technol ; 98(1): 135-144, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-28053463

RESUMO

The features of two fundamental neutron physics research stations at the NIST cold neutron research facility are described in some detail. A list of proposed initial experimental programs for these two stations is also given.