Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.909
Filtrar
Mais filtros








Intervalo de ano de publicação
2.
Artigo em Inglês | MEDLINE | ID: mdl-39357781

RESUMO

OBJECTIVE: Thoraco-abdominal normothermic regional perfusion (TA-NRP) has emerged as a strategy for evaluating and recovering the heart in controlled donation after the circulatory determination of death (cDCDD). However, its impact on lung grafts remains largely unknown. We aimed to assess the impact of TA-NRP on the outcomes of recipients of cDCDD lungs. METHODS: This is a retrospective, multicenter, nationwide study describing the outcomes of cDCDD lung transplants (LTs) performed in Spain from January 2021 to November 2023. Patients were divided in two groups based on the recovery technique: TA-NRP with the simultaneous recovery of the heart versus abdominal NRP (A-NRP) without simultaneous heart recovery. The primary endpoint was the incidence of Primary Graft Dysfunction (PGD) grade 3 at 72 hours. Secondary endpoints included the overall incidence of PGD, days on mechanical ventilation, ICU and hospital length of stay, early survival rates, and mid-term outcomes. RESULTS: 283 cDCDD LTs were performed during the study period, 28 (10%) using TA-NRP and 255 (90%) using A-NRP. No differences were observed in the incidence of PGD grade 3 at 72 hours between the TA-NRP and the A-NRP group (0% vs. 7.6%; p=0.231), though the overall incidence of PGD was significantly lower with TA-NRP (14.3%% vs. 41.5%; p=0.005). We found no significant differences between the groups regarding other post-transplant outcome variables. CONCLUSIONS: TA-NRP allows the simultaneous recovery of both the heart and the lungs in the cDCDD scenario with appropriate LT outcomes comparable to those observed with the A-NRP approach.

3.
J Nucl Med ; 2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39362762

RESUMO

The Registry of Fast Myocardial Perfusion Imaging with Next-Generation SPECT (REFINE SPECT) has been expanded to include more patients and CT attenuation correction imaging. We present the design and initial results from the updated registry. Methods: The updated REFINE SPECT is a multicenter, international registry with clinical data and image files. SPECT images were processed by quantitative software and CT images by deep learning software detecting coronary artery calcium (CAC). Patients were followed for major adverse cardiovascular events (MACEs) (death, myocardial infarction, unstable angina, late revascularization). Results: The registry included scans from 45,252 patients from 13 centers (55.9% male, 64.7 ± 11.8 y). Correlating invasive coronary angiography was available for 3,786 (8.4%) patients. CT attenuation correction imaging was available for 13,405 patients. MACEs occurred in 6,514 (14.4%) patients during a median follow-up of 3.6 y (interquartile range, 2.5-4.8 y). Patients with a stress total perfusion deficit of 5% to less than 10% (unadjusted hazard ratio [HR], 2.42; 95% CI, 2.23-2.62) and a stress total perfusion deficit of at least 10% (unadjusted HR, 3.85; 95% CI, 3.56-4.16) were more likely to experience MACEs. Patients with a deep learning CAC score of 101-400 (unadjusted HR, 3.09; 95% CI, 2.57-3.72) and a CAC of more than 400 (unadjusted HR, 5.17; 95% CI, 4.41-6.05) were at increased risk of MACEs. Conclusion: The REFINE SPECT registry contains a comprehensive set of imaging and clinical variables. It will aid in understanding the value of SPECT myocardial perfusion imaging, leverage hybrid imaging, and facilitate validation of new artificial intelligence tools for improving prediction of adverse outcomes incorporating multimodality imaging.

4.
J Artif Organs ; 2024 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-39363050

RESUMO

We established a compact machine perfusion system for whole blood perfusion of rat liver by making use of oxygenation filters as an artificial lung. Livers removed from rats were divided into Krebs-Henseleit (control), 50% blood (hemoglobin: 7 g/dL), and whole blood (hemoglobin: 14 g/dL) groups, then perfused (total perfusate volume: 25 ml) with a small oxygenation filter at 37 °C for 120 min. Blood or perfusate was collected over time, and blood gas and blood cell were measured. In addition, bile volume and portal venous pressure measurements were taken. In all groups, the partial pressure of oxygen was controlled to approximately 400 mmHg. Flow rates were maintained at approximately about 20-30 ml/min according to liver size. Portal venous pressure was normal in the 50% blood and whole blood groups, while lower than the reference value in the Krebs-Henseleit group. Twice as much bile was produced in the 50% blood and whole blood groups relative with the Krebs-Henseleit group. We observed no differences in hemoglobin and red blood cell levels. Lactate levels were normal in the 50% blood and whole blood groups, but were elevated in the Krebs-Henseleit group. Our compact perfusion system using oxygenation filters was able to maintain rat liver function by perfusing a small amount of extracorporeal blood. This system is simple and stable, and may contribute to the future development of machine perfusion systems.

5.
Digit Health ; 10: 20552076241284910, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39351311

RESUMO

Objective: This study aims to assess the accuracy and stability of smartwatches in predicting acute mountain sickness (AMS). Methods: In locations exceeding an altitude of 2500 m, a cohort of 42 subjects had their Lake Louise AMS self-assessment score, blood oxygen saturation (SpO2), heart rate, and perfusion index measured using smartwatches, with the data seamlessly conveyed to the Huawei Cloud. Results: A significant decrease in SpO2 was observed in individuals positive for AMS compared to those negative (p < 0.05), with the mild AMS group exhibiting significantly lower SpO2 levels than the non-AMS group (p < 0.05). Furthermore, SpO2 emerged as a significant, independent predictor of AMS [ß=-0.086, p < 0.01, OR (95% CI) = 0.92 (0.87-0.97)], indicating that each unit increase in SpO2 decreases the probability of AMS occurrence by 8.6%. Conclusion: The Huawei smartwatches have demonstrated efficacy in diagnosing and foretelling AMS at elevations exceeding 4000 m, showcasing significant reliability and high precision in SpO2 measurement.

7.
Front Nucl Med ; 4: 1232135, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39355219

RESUMO

Introduction: Single-photon emission computed tomography (SPECT) and positron emission tomography (PET) are non-invasive nuclear medicine techniques that can identify areas of abnormal myocardial perfusion. We assessed the prevalence of cardiovascular risk factors in patients with suspected coronary artery disease (CAD) undergoing SPECT or PET stress myocardial perfusion imaging (MPI). Based on significant risk factors associated with an abnormal MPI, we developed a nomogram for each cohort as a pretest that would be helpful in decision-making for clinicians. Methods: A total of 6,854 patients with suspected CAD who underwent stress myocardial perfusion imaging by SPECT or PET/CT was studied. As part of the baseline examination, clinical teams collected information on traditional cardiovascular risk factors: age, gender, body mass index, angina, dyspnea, diabetes, hypertension, hyperlipidemia, family history of CAD, and smoking. Results: The prevalence of cardiovascular risk factors was different in the two cohorts of patients undergoing SPECT (n = 4,397) or PET (n = 2,457) myocardial perfusion imaging. A statistical significance was observed in both cohorts for age, gender, and diabetes. At multivariable analysis, only age and male gender were significant covariates in both cohorts. The risk of abnormal myocardial perfusion imaging related to age was greater in patients undergoing PET (odds ratio 4% vs. 1% per year). In contrast, male gender odds ratio was slightly higher for SPECT compared to PET (2.52 vs. 2.06). In the SPECT cohort, smoking increased the risk of abnormal perfusion of 24%. Among patients undergoing PET, diabetes and hypertension increased the risk of abnormal perfusion by 63% and 37%, respectively. For each cohort, we obtained a nomogram by significant risk factors at multivariable logistic regression. The area under the receiver operating characteristic curve associated with the nomogram was 0.67 for SPECT and 0.73 for the PET model. Conclusions: Patients with suspected CAD belonging to two different cohorts undergoing SPECT or PET stress myocardial perfusion imaging can have different cardiovascular risk factors associated with a higher risk of an abnormal MPI study. As crude variables, age, gender, and diabetes were significant for both cohorts. Net of the effect of other covariates, age and gender were the only risk factors in common between the two cohorts. Furthermore, smoking and type of stress test were significant for the SPECT cohort, where as diabetes and hypertension were significant for the PET cohort. Nomograms obtained by significant risk factors for the two cohorts can be used by clinicians to evaluate the risk of an abnormal study.

8.
J Crit Care ; 85: 154928, 2024 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-39388973

RESUMO

PURPOSE: Transesophageal echocardiography (TEE) may cause an increase in intracerebral pressure (ICP). Data are currently lacking. METHODS: Monocentric observational study. Continuous monitoring of ICP, cerebral perfusion pressure (CPP) and mean arterial pressure (MAP) before, during, and after TEE. The first 10 patients were positioned in the left lateral position (left lateral tilt group = LLTG). Further patients were examined in the supine position (supine position group = SPG). RESULTS: A total of 20 patients with a median age of 59 ± 20.1 years were included in the study. The median baseline ICP was 9 ± 4.3 mmHg in LLTG and 4 ± 5.1 mmHg in SPG. Only LLTG showed a significant increase in ICP from baseline to TEE (p = 0.013). When comparing both groups, a significantly longer procedure duration was found in the positioning group (LLTG = 14.5 min versus SPG = 9.5 min; p = 0.002). CONCLUSION: This study is the first to investigate the effect of transesophageal echocardiography on ICP and CPP. Our data demonstrated a temporary increase in ICP during TEE probably caused by lateral positioning the patients. For patients at risk with critically elevated ICP values, TEE should only be performed in the supine position.

9.
Artigo em Inglês | MEDLINE | ID: mdl-39389331

RESUMO

BACKGROUND: Donation after circulatory death (DCD) and ex-vivo lung perfusion (EVLP) have been adopted to expand the donor pool in lung transplantation, but outcomes data have been conflicting. This study explores mid-term outcomes of DCD lung transplantation in the modern era, with a focus on EVLP and risk factors for graft failure. METHODS: The United Network for Organ Sharing (UNOS) database was queried for adult lung transplants from 1/1/2015 to 3/1/2023. Loss to follow-up, multiorgan and prior lung transplants were excluded. DCD vs DBD (donation after brain death) lung transplants were compared, with subgroup analysis +/- EVLP. Outcomes were survival and postoperative complications. Overall survival was analyzed separately for an early era (2015-2018) and modern era (2019-2023). RESULTS: The study included 1103 DCD (221 with EVLP, and 882 without) and 17973 donation after brain death (DBD) lung transplants (524 with EVLP, and 17449 without). Median follow-up was 3 years. DCD donors were less likely to be CDC high risk (19.3% vs 24.1%, p<0.001), have purulence on bronchoscopy (13.3% vs 18.3%, p<0.001) or infiltrates on chest x-ray (66.7% vs 67.8%, p=0.013). EVLP was more likely to be used for DCD transplants (20.0% vs 2.9%, p<0.001). After transplant, DCD recipients were more likely to be reintubated (24.3% vs 18.5%, p<0.001) and require ECMO within 72 hours (14.9% vs 7.8%, p<0.001), and DCD donation was an independent risk factor for these complications on multivariable logistic regression. Overall survival did not differ significantly between DCD and DBD transplants on adjusted survival analysis in the early or modern era (p=0.774 and p=0.468 respectively). On multivariable Cox regression, DCD and EVLP were not independent risk factors for mortality. On subgroup analysis, the DCD+EVLP cohort had significantly worse survival in the modern era, which remained significant after adjusting for donor and recipient factors (p=0.005). EVLP was an independent risk factor for graft failure in the DCD cohort (HR 1.33, 95% CI 1.00-1.77, p=0.047), but did not significantly affect DBD graft survival (p=0.870). Risk factors for graft failure and mortality in the DCD+EVLP cohort included pulmonary hypertension (HR 77.5, 95% CI 6.15-979, p<0.001), transfusion prior to transplant (HR 2.60, 95% CI 1.07-6.31, p=0.035), elevated creatinine (HR 2.82, 95% CI 1.34-5.90, p=0.006), and higher allocation score (HR 1.02, 95% CI 1.00-1.04, p=0.017) CONCLUSION: Study findings suggest increased risks of mortality and perioperative complications following transplantation with DCD lungs that have undergone EVLP. DCD lung transplantation without EVLP confers equivalent survival but with some increase in perioperative complications. Further investigation and careful recipient selection is warranted to optimize the use of these extended criteria donors in the modern era.

10.
Int J Mol Med ; 54(6)2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39370783

RESUMO

To meet the demand for kidney transplants (KTx), organs are frequently retrieved not only from standard criteria donors (SCD; a donor who is aged <50 years and suffered brain death from any number of causes, such as traumatic injuries or a stroke) but also from expanded criteria donors (any donor aged >60 years or donors aged >50 years with two of the following: A history of high blood pressure, a creatinine serum level ≥1.5 mg/dl or death resulting from a stroke). This comes at the cost of a higher risk of primary non­function (the permanent hyperkalemia, hyperuremia and fluid overload that result in the need for continuous dialysis after KTx), delayed graft function (the need for dialysis session at least once during the first week after KTx), earlier graft loss and urinary complications (vesico­ureteral reflux, obstruction of the vesico­ureteral anastomosis, urine leakage). At present, there are no commercially available diagnostic tools for assessing kidney quality prior to KTx. Currently available predictive models based on clinical data, such as the Kidney Donor Profile Index, are insufficient. One promising option is the application of perfusion solutions for protein biomarkers of kidney quality and predictors of short­ and long­term outcomes. However, to date, protein markers that can be detected with ELISA, western blotting and cytotoxic assays have not been identified to be a beneficial predictors of kidney quality. These include lactate dehydrogenases, glutathione S­transferases, fatty acid binding proteins, extracellular histones, IL­18, neutrophil gelatinase­associated lipocalin, MMPs and kidney injury molecule­1. However, novel methods, including liquid chromatography­mass spectrometry (LC­MS) and microarrays, allow the analysis of all renal proteins suspended/dissolved in the acellular preservation solution used for kidney storage before KTx (including hypothermic machine perfusion as one of kidney storage methods) e.g. Belzer University of Wisconsin. Recent proteomic studies utilizing LC­MS have identified complement pathway elements (C3, C1QB, C4BPA, C1S, C1R and C1RL), desmoplakin, blood coagulation pathway elements and immunoglobulin heavy variable 2­26 to be novel predictors of kidney quality before transplantation. This was because they were found to correlate with estimated glomerular filtration rate at 3 and 12 months after kidney transplantation. However, further proteomic studies focusing on distinct markers obtained from hypothermic and normothermic machine perfusion are needed to confirm their predictive value and to improve kidney storage methods. Therefore, the present literature review from PubMed, Scopus, Embase and Web of Science was performed with the aims of summarizing the current knowledge on the most frequently studied single protein biomarkers. In addition, novel analytical methods and insights into organ injury during preservation were documented, where future directions in assessing organ quality before kidney transplantation were also discussed.


Assuntos
Biomarcadores , Transplante de Rim , Rim , Humanos , Rim/metabolismo , Doadores de Tecidos
11.
Artigo em Inglês | MEDLINE | ID: mdl-39382154

RESUMO

AIMS: The diagnostic performance of quantitative perfusion cardiac magnetic resonance (QP-CMR) imaging has scarcely been evaluated in patients with a history of coronary artery disease (CAD) and new onset chest pain. The present study compared the diagnostic performance of automated QP-CMR for detection of fractional flow reserve (FFR) defined hemodynamically significant CAD with visual assessment of first-pass stress perfusion CMR (v-CMR) and quantitative [15O]H2O positron emission tomography (PET) imaging in a true head-to-head fashion in patients with prior CAD. METHODS AND RESULTS: This PACIFIC-2 substudy included 145 symptomatic chronic coronary symptom patients with prior myocardial infarction (MI) and/or percutaneous coronary intervention (PCI). All patients underwent dual-sequence, single bolus perfusion CMR and [15O]H2O PET perfusion imaging followed by invasive coronary angiography with three-vessel FFR. Hemodynamically significant CAD was defined as an FFR ≤0.80. QP-CMR, v-CMR and PET exhibited a sensitivity of 66%, 67%, and 80%, respectively, whereas specificity was 60%, 62%, and 63%. Sensitivity of QP-CMR was lower than PET (P=0.015), whereas specificity of QP-CMR and PET was comparable. Diagnostic accuracy and area under the curve (AUC) of QP-CMR (64% and 0.66) was comparable to both v-CMR (66% [P=NS] and 0.67 (P=NS]) and PET (74% [P=NS] and 0.78 [P=NS]). CONCLUSIONS: In patients with prior MI and/or PCI, the diagnostic performance of QP-CMR was comparable to visual assessment of first-pass stress perfusion CMR and quantitative [15O]H2O PET for the detection of hemodynamically significant CAD as defined by FFR.

12.
Acta Neurochir (Wien) ; 166(1): 400, 2024 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-39382579

RESUMO

BACKGROUND: Various methods for measuring intrathecal pressure (ITP) after spinal cord injury (SCI) to guide hemodynamic management have been investigated. To synthesize the current literature, this current study conducted a scoping review of the use of intrathecal devices to monitor ITP during acute management of SCI with the aim of understanding the association between ITP monitoring with physiological and clinical outcomes. METHODS: A systematic review of literature following the Cochrane Handbook for Systematic Reviews of Interventions and Preferred Reporting Items for Systematic Reviews and Meta-Analysis statement. All eligible studies were screened for inclusion and exclusion criteria. Data extracted included number of patients included, severity of injury, characteristics of the intervention-intrathecal device used to record the ITP, outcomes -hemodynamic parameters observed, changes in the American Spinal Injury Association (ASIA) Impairment Scale (AIS), total motor scores, association of ITP with other physiological variables. RESULTS: The search yielded a total of 1,698 articles, of which 30 observational studies and 2 randomized clinical trials were deemed eligible based on their use of an intrathecal invasive device to monitor spinal cord perfusion pressure (SCPP) in patients with SCI. Of these, 9 studies used a lumbar drain, 23 a Codman pressure probe and 1 study that used both. These studies underscore the crucial interplay between ITP, the SCPP and physiological variables, with neurological outcome. It is still unclear whether monitoring from a lumbar drain is accurate enough to highlight what is occurring at the site of SCI, which is the main advantage of Codman Probe, however, the latter requires specialized personnel that may not be available in most settings. Minor adverse effects were associated with lumbar drain catheters, while cerebrospinal fluid leak requiring repair (~ 7%) is the main concern with Codman Probes. CONCLUSION: Future investigation of SCPP protocols via lumbar drains and Codman probes ought to involve multi-centered randomized controlled trials and continued translational investigation with animal models.


Assuntos
Hemodinâmica , Traumatismos da Medula Espinal , Humanos , Traumatismos da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/terapia , Hemodinâmica/fisiologia , Pressão do Líquido Cefalorraquidiano/fisiologia , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Medula Espinal/fisiopatologia
13.
Curr Cardiol Rep ; 2024 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-39382782

RESUMO

PURPOSE OF REVIEW: To summarise current international clinical outcomes from donation after circulatory death heart transplantation (DCD-HT); discuss procurement strategies, their impact on outcomes and overall organ procurement; and identify novel approaches and future areas for research in DCD-HT. RECENT FINDINGS: Globally, DCD-HT survival outcomes (regardless of procurement strategy) are comparable to heart transplantation from brain dead donors (BDD). Experience with normothermic machine perfusion sees improvement in rates of primary graft dysfunction. Techniques have evolved to reduce cold ischaemic exposure to directly procured DCD hearts, though controlled periods of cold ischaemia can likely be tolerated. There is interest in hypothermic machine perfusion (HMP) for directly procured DCD hearts, with promising early results. Survival outcomes are firmly established to be equivalent between BDD and DCD-HT. Procurement strategy (direct procurement vs. regional perfusion) remains a source of debate. Methods to improve allograft warm ischaemic tolerance are of interest and will be key to the uptake of HMP for directly procured DCD hearts.

14.
Lab Anim ; : 236772241256023, 2024 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-39391969

RESUMO

Obtaining sufficient blood volume from mice significantly facilitates experimental research. This study explored the inferior vena cava puncture under continuous cardiac perfusion (IVCP-UCCP) technique and evaluated its efficiency in comparison with conventional cardiac puncture (CP). In an initial dose-finding study, 50 mice were randomly assigned to one of 10 groups with escalating perfusion volume from 0.5 to 4.5 ml in 0.5-ml increments. The minimum perfusion volume was determined to be 2 ml in collecting whole circulating blood. In the next comparison using the conventional method, 40 mice were randomly assigned to one of two groups denoting different blood collection methods: Group 1: CP, Group 2: IVCP-UCCP. The results showed 1) that the cells and undiluted blood volume collected via IVCP-UCCP was over twofold higher than that by CP (p < 0.001), confirmed by the cell counts and hematoxylin-eosin staining of different tissues slides (p < 0.001); 2) the new technique did not alter the cellular composition or viability, which was verified by routine blood tests and flow cytometry (p > 0.05); 3) the blood collected via the novel technique was diluted 2.1 times: the hemato-biochemical indicator results multiplied by 2.1 were identical with the test results of blood from CP (p > 0.05). Together, the refined blood collection method of IVCP-UCCP completely extracted the limited blood resources in mice, significantly enhanced the utilization of each mouse, and thus offered scientific and ethical benefits. This technique may be also applicable for other small animal models.

15.
Stroke ; 2024 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-39391984

RESUMO

BACKGROUND: In acute stroke, diffusion-weighted imaging (DWI) is used to assess the ischemic core. Dynamic-susceptibility contrast perfusion magnetic resonance imaging allows an estimation of the oxygen extraction fraction (OEF), but the outcome of DWI lesions with increased OEF postrecanalization is unclear. This study investigated the impact of OEF on the fate of DWI lesions in patients achieving recanalization after thrombectomy. METHODS: This was a retrospective analysis of the HIBISCUS-STROKE cohort (Cohort of Patients to Identify Biological and Imaging Markers of Cardiovascular Outcomes in Stroke; NCT: 03149705), a single-center observational study that prospectively enrolled patients who underwent magnetic resonance imaging triage for thrombectomy and a day-6 T2-fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging. Automated postprocessing of admission dynamic-susceptibility contrast perfusion magnetic resonance imaging generated OEF maps. At visual analysis, the OEF status within DWI lesions was assessed in comparison to the contralateral side and correlated with volume changes (difference of ischemic lesion between admission DWI and registered day-6 T2-FLAIR). At voxel-based analysis, recovered DWI regions (lesions present on the admission DWI but absent on the registered day-6 T2-FLAIR) and nonrecovered regions were segmented to extract semiquantitative OEF values. RESULTS: Of the participants enrolled from 2016 to 2022, 134 of 321 (41.7%) were included (median age, 71.0 years; 58.2% male; median baseline National Institutes of Health Scale score, 15.0). At visual analysis, 46 of 134 (34.3%) patients had increased OEF within DWI lesions. These patients were more likely to show a reduction in ischemic lesion volumes compared with those without increased OEF (median change, -4.0 versus 4.8 mL; P<0.0001). Multivariable analysis indicated that increased OEF within DWI lesions was associated with a reduction in ischemic lesion volumes from admission DWI to day-6 T2-FLAIR (odds ratio, 0.68 [95% CI, 0.49-0.87]; P=0.008). At voxel-based analysis, recovered DWI regions had increased OEF, while nonrecovered regions had decreased OEF (median, 126.9% versus -27.0%; P<0.0001). CONCLUSIONS: Increased OEF within hyperacute DWI lesions was associated with ischemic lesion recovery between admission DWI and day-6 T2-FLAIR in patients achieving recanalization after thrombectomy. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03149705.

16.
Arch Physiol Biochem ; : 1-10, 2024 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-39392336

RESUMO

CONTEXT: Energy homeostasis is a primary factor for the survival of mammals. Many tissues and organs, among which is the liver, keep this homeostasis in varied circumstances, including caloric restriction (CR) and physical activity. OBJECTIVE: This study investigated glucose metabolism using the following groups of eight-week-old male Swiss mice: CS, sedentary and fed freely; RS, sedentary and RT, trained, both under 30% CR (n = 20-23 per group). RESULTS: Organs and fat depots of groups RS and RT were similar to CS, although body weight was lower. CR did not impair training performance nor affected systemic or hepatic glucose metabolism. Training combined with CR (group RT) improved in vivo glucose tolerance and did not affect liver gluconeogenesis. CONCLUSIONS: The mice tolerated the prolonged moderate CR without impairment of their well-being, glucose homeostasis, and resistance training performance. But the higher liver gluconeogenic efficiency previously demonstrated using this training protocol in mice was not evidenced under CR.

17.
Artigo em Inglês | MEDLINE | ID: mdl-39392606

RESUMO

BACKGROUND: Perfusion index (PI) and CRIB (Clinical risk index of babies) Score II both are minimally invasive tools for prediction of mortality and morbidity in sick neonates. This study aims to know the predictive values of both PI and CRIB Score II in assessment of severity of illness in preterm neonates of 28 to 32 weeks and their correlation. METHODS: PI and CRIB II Score of 125 sick preterm neonates admitted in NICU were assessed within 12 hours of admission. Severity noted in form of outcome. Correlation between PI and CRIB Score II were observed. RESULTS: Receiver operating characteristic (ROC) curve were plotted for PI and CIRB Score II with outcome (discharged vs expired). Area under curve for perfusion index was 0.776 at 95% confidence interval. Optimum cutoff point based on ROC curve was 1.65 with sensitivity of 84%., specificity of 37.2% with positive predictive value of 70% and negative predictive value of 57%. Area under curve for CRIB Score II was 0.622 (p value < 0.028), optimum cut off point based on ROC curve for CRIB II score was 3.5 with sensitivity 79.10% of specificity of 40% positive predictive value is 43.03% and negative predictive value of 76.9%. Spearman's correlation coefficient between PI and CRIB II score was -0.272 and p value is 0.002. CONCLUSION: This study concluded that perfusion index (p < 0.001) is better for predicting the severity compared to CRIB II score (p < 0.028). A weak negative correlation exists between PI and CRIB II score (r = -0.272).

18.
Surg Case Rep ; 10(1): 235, 2024 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-39379753

RESUMO

BACKGROUND: Gastroschisis is a rare congenital anomaly in which abdominal organs herniate through a defect in the abdominal wall. Managing gastroschisis in extremely low birth weight (ELBW) infants presents significant challenges because of their immature physiologies and increased risk of complications. CASE PRESENTATION: This report discusses the case of a female ELBW infant born via an emergency cesarean section at 29 weeks of gestation, weighing 768 g, who had a prenatal diagnosis of gastroschisis. Postnatal management included immediate surgical intervention using a hand-made silo manufactured from expanded polytetrafluoroethylene (ePTFE) sheets that were sutured to the patient's abdominal wall to accommodate her small abdominal cavity and preserve mesenteric blood flow. Necrotizing enterocolitis with bowel perforation emerged as a complication, which led to the excision of a 10 cm segment of the ileum and the creation of an ileostomy. The infant experienced insufficient weight gain and liver dysfunction. However, she was eventually discharged on day 142 of life, weighing 2774 g, on oral feeding, without significant complications. CONCLUSIONS: This case emphasizes how prematurity significantly affected the patient's clinical outcomes, and highlights the importance of individualized management strategies. Our experience demonstrates that custom silo placement allows for the size to be adapted to the abdominal defect, and highlights the critical need to prioritize postnatal bowel perfusion in ELBW infants with gastroschisis.

19.
BMC Cardiovasc Disord ; 24(1): 543, 2024 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-39379835

RESUMO

BACKGROUND: Coronary artery disease (CAD) is associated with a large clinical and economic burden. However, consensus on the optimal approach to CAD diagnosis is lacking. This study sought to compare downstream healthcare resource utilisation following different cardiac imaging modalities, to inform test selection for CAD diagnosis. METHODS: Claims and electronic health records data from the Decision Resources Group Real-World Evidence US Data Repository were analysed for 2.5 million US patients who underwent single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI), positron emission tomography myocardial perfusion imaging (PET MPI), coronary computed tomography angiography (cCTA), or stress echocardiography between January 2016 and March 2018. Patients were stratified into nine cohorts based on suspected or existing CAD diagnosis, pre-test risk, and prior events or interventions. Downstream healthcare utilisation, including additional diagnostic imaging, coronary angiography, and cardiac-related health system encounters, was compared by cohort and index imaging modality. RESULTS: Among patients with suspected CAD diagnosed within 3 months of the index test, PET MPI was associated with lower downstream utilisation; 25-37% of patients who underwent PET MPI required additional downstream healthcare resources compared with 40-49% of patients who received SPECT MPI, 35-41% of patients who underwent cCTA, and 44-47% of patients who received stress echocardiography. Patients who underwent PET MPI experienced fewer acute cardiac events (5.3-9.4%) and generally had lower rates of healthcare encounters (0.8-4.1%) and invasive coronary angiography (ICA, 15.4-24.2%) than those who underwent other modalities. SPECT MPI was associated with more downstream ICA (31.3-38.2%) and a higher rate of cardiac events (9.5-13.2%) compared with PET MPI (5.3-9.4%) and cCTA (6.9-9.9%). Across all cohorts, additional diagnostic imaging was 1.6 to 4.7 times more frequent with cCTA compared with PET MPI. CONCLUSION: Choice of imaging modality for CAD diagnosis impacts downstream healthcare utilisation. PET MPI was associated with lower utilisation across multiple metrics compared with other imaging modalities studied.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Ecocardiografia sob Estresse , Imagem de Perfusão do Miocárdio , Valor Preditivo dos Testes , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Masculino , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Estados Unidos , Pessoa de Meia-Idade , Idoso , Bases de Dados Factuais , Tomografia por Emissão de Pósitrons , Fatores de Tempo , Demandas Administrativas em Assistência à Saúde , Registros Eletrônicos de Saúde
20.
EJNMMI Phys ; 11(1): 80, 2024 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-39356406

RESUMO

BACKGROUND: Deep learning (DL)-based denoising has been proven to improve image quality and quantitation accuracy of low dose (LD) SPECT. However, conventional DL-based methods used SPECT images with mixed frequency components. This work aims to develop an integrated multi-frequency denoising network to further enhance LD myocardial perfusion (MP) SPECT denoising. METHODS: Fifty anonymized patients who underwent routine 99mTc-sestamibi stress SPECT/CT scans were retrospectively recruited. Three LD datasets were obtained by reducing the 10 s acquisition time of full dose (FD) SPECT to be 5, 2 and 1 s per projection based on the list mode data for a total of 60 projections. FD and LD projections were Fourier transformed to magnitude and phase images, which were then separated into two or three frequency bands. Each frequency band was then inversed Fourier transformed back to the image domain. We proposed a 3D integrated attention-guided multi-frequency conditional generative adversarial network (AttMFGAN) and compared with AttGAN, and separate AttGAN for multi-frequency bands denoising (AttGAN-MF).The multi-frequency FD and LD projections of 35, 5 and 10 patients were paired for training, validation and testing. The LD projections to be tested were separated to multi-frequency components and input to corresponding networks to get the denoised components, which were summed to get the final denoised projections. Voxel-based error indices were measured on the cardiac region on the reconstructed images. The perfusion defect size (PDS) was also analyzed. RESULTS: AttGAN-MF and AttMFGAN have superior performance on all physical and clinical indices as compared to conventional AttGAN. The integrated AttMFGAN is better than AttGAN-MF. Multi-frequency denoising with two frequency bands have generally better results than corresponding three-frequency bands methods. CONCLUSIONS: AttGAN-MF and AttMFGAN are promising to further improve LD MP SPECT denoising.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA