Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Total Environ ; 952: 175853, 2024 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-39222807

RESUMO

Sewer pipe materials exhibit diverse inner-surface features, which can affect the attachment of biofilm and influence microbial metabolic processes. To investigate the role of the type of pipe material on the composition and metabolic capabilities of the adhering microorganisms, three sets of urban sewers (High-Density Polyethylene Pipe (HDPE), Ductile Iron Pipe (DIP), and Concrete Pipe (CP)) were constructed. Measurements of biofilm thickness and environmental factors revealed that the thickest biofilm in CP pipes reached 2000 µm, with ORP values as low as -325 mV, indicating a more suitable anaerobic microbial habitat. High-throughput sequencing showed similar relative abundances of genera related to carbon and sulfur metabolism in the DIP and CP pipes, whereas HDPE exhibited only half the relative abundance compared to that found in the other pipes. To explore the impact of pipe materials on the mechanisms of microbial response, a metagenomic approach was used to investigate the biological transformation of carbon and sulfur in wastewater. The annotations of the crucial enzyme-encoding genes related to methyl coenzyme M and sulfite reductase in DIP and CP were 50 and 110, respectively, whereas HDPE exhibited lower counts (25 and 70, respectively). This resulted in significantly lower carbon and sulfur metabolism capabilities in the HDPE biofilm than in the other two pipes. The stability of wastewater quality during the transmission process in HDPE pipes reduces the metabolic generation of toxic and harmful gases within the pipes, favoring the preservation of carbon sources for sewer systems. This study reveals the variations in carbon and sulfur metabolism in wastewater pipe systems influenced by pipe materials and provides insights for designing future sewers.


Assuntos
Biofilmes , Esgotos/microbiologia , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias
2.
Arch Microbiol ; 206(7): 295, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38856934

RESUMO

Microbial community biofilm exists in the household drinking water system and would pose threat to water quality. This paper explored biofilm formation and chlorination resistance of ten dual-species biofilms in three typical household pipes (stainless steel (SS), polypropylene random (PPR), and copper), and investigated the role of interspecific interaction. Biofilm biomass was lowest in copper pipes and highest in PPR pipes. A synergistic or neutralistic relationship between bacteria was evident in most biofilms formed in SS pipes, whereas four groups displayed a competitive relationship in biofilms formed in copper pipe. Chlorine resistance of biofilms was better in SS pipes and worse in copper pipes. It may be helped by interspecific relationships, but was more dependent on bacteria and resistance mechanisms such as more stable extracellular polymeric substance. The corrosion sites may also protect bacteria from chlorination. The findings provide useful insights for microbial control strategies in household drinking water systems.


Assuntos
Bactérias , Biofilmes , Cloro , Água Potável , Biofilmes/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Cloro/farmacologia , Bactérias/efeitos dos fármacos , Bactérias/genética , Bactérias/isolamento & purificação , Bactérias/classificação , Água Potável/microbiologia , Cobre/farmacologia , Microbiologia da Água , Aço Inoxidável , Polipropilenos , Abastecimento de Água , Halogenação , Corrosão , Desinfetantes/farmacologia
3.
Environ Sci Technol ; 57(50): 21382-21394, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38071676

RESUMO

In-building disinfectants are commonly applied to control the growth of pathogens in plumbing, particularly in facilities such as hospitals that house vulnerable populations. However, their application has not been well optimized, especially with respect to interactive effects with pipe materials and potential unintended effects, such as enrichment of antibiotic resistance genes (ARGs) across the microbial community. Here, we used triplicate convectively mixed pipe reactors consisting of three pipe materials (PVC, copper, and iron) for replicated simulation of the distal reaches of premise plumbing and evaluated the effects of incrementally increased doses of chlorine, chloramine, chlorine dioxide, and copper-silver disinfectants. We used shotgun metagenomic sequencing to characterize the resulting succession of the corresponding microbiomes over the course of 37 weeks. We found that both disinfectants and pipe material affected ARG and microbial community taxonomic composition both independently and interactively. Water quality and total bacterial numbers were not found to be predictive of pathogenic species markers. One result of particular concern was the tendency of disinfectants, especially monochloramine, to enrich ARGs. Metagenome assembly indicated that many ARGs were enriched specifically among the pathogenic species. Functional gene analysis was indicative of a response of the microbes to oxidative stress, which is known to co/cross-select for antibiotic resistance. These findings emphasize the need for a holistic evaluation of pathogen control strategies for plumbing.


Assuntos
Desinfetantes , Água Potável , Engenharia Sanitária , Desinfetantes/farmacologia , Abastecimento de Água , Antibacterianos/farmacologia , Cobre , Proliferação de Células
4.
Environ Sci Pollut Res Int ; 30(56): 118065-118077, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37924396

RESUMO

The water quality implications of transferring stormwater through pipes composed of concrete (new and used), polyvinyl chloride (PVC), galvanized corrugated steel (GCS), high-density polyethylene (HDPE), and pipes subjected to cured in place pipe (CIPP) and spray in place pipe (SIPP) trenchless repair technologies on stormwater quality are reviewed. Studies involve either the use of flowing water or an immersion experimental design, with data showing contact with pipe materials can affect stormwater quality parameters including pH, electrical conductivity (EC), and concentrations of minerals, metals, and organic constituents, e.g. styrene. 'In-transport' changes in pH (1-3 units), EC (2-3-fold), bicarbonate (3-44-fold), and calcium (2-17-fold) in stormwaters were reported following exposure to concrete pipes. Differences between the use of synthetic and field-collected stormwater were identified, e.g. turbidity levels in field-collected stormwater reduced on passage through all pipe types, compared to synthetic water where levels of turbidity on exposure to concrete and cement-based SIPP increased slightly. Transfer through PVC and HDPE pipes had minimal effects on physicochemical parameters, whereas exposure to galvanized corrugated steel pipes led to increases in EC, Zn, and Pb. Though limited data was available, the use of CIPP repairs and associated waste condensate generated during thermal curing and/or incomplete curing of resins was identified to release organic contaminants of concerns (e.g. styrene, vinylic monomers, dibutyl phthalate (DBP), diethyl phthalate (DEP), and benzaldehyde). The implications of findings for both future research and stakeholders with responsibility for reducing diffuse pollution loads to receiving waters are considered.


Assuntos
Polietileno , Qualidade da Água , Estireno , Dibutilftalato , Aço
5.
Polymers (Basel) ; 14(23)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36501629

RESUMO

The high recycling targets set by the European Commission will create an increased availability of polypropylene (PP) post-consumer recyclates (PCRs). However, no regulations mandate the use of recycled PP (rPP), so the industry is challenged to explore possibilities to utilize such materials. One option, as suggested by the European Commission, is the introduction of rPP in pipe applications. According to existing standards, the use of recyclate is not allowed in pressurized gas and drinking water systems. However, many other pipe and underground applications, such as stormwater systems, open the increased use of PCRs. Additionally, even for less-demanding applications, such as non-pressure sewage systems, highly durable solutions are needed to cover the requested lifetime and request an ambitious property profile to fulfill the application needs that cannot be met by PP packaging materials and even less by PCRs thereof. Hence, this work explores the possible use of commercially available PCRs out of polypropylene from packaging applications in compounds together with virgin PP pipe grades to meet the demands for less-demanding applications. Two different commercially available rPPs and one commercially available recycled polyolefin (rPO) from mixed polyethylene and PP waste were acquired and, together with two predefined virgin PP pipe grades, were blended to compounds in the range of 10 m%, 20 m%, and 30 m% recyclate content. The compounds and three virgin PP pipe grades, acting as benchmarks, were tested in terms of short- and long-term mechanical performance as well as for many other physical properties. All of the compounds showed good results regarding fatigue crack (FCG) resistance with virgin polymer as the reference. The factors influencing FCG resistance, such as melt flow rate and polyolefin cross-contamination, were thoroughly investigated as the used virgin grades and recyclates cover a broad range of these properties.

6.
Sci Total Environ ; 851(Pt 2): 158263, 2022 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-36030876

RESUMO

Bio-clogging in pipes poses a significant threat to the operation of leachate collection systems. Bio-clogging formation is influenced by the pipe materials. However, the relationship between bio-clogging and the physicochemical properties of different pipe materials has not been clarified yet, especially from a thermodynamic aspect. In this study, the dynamic bio-clogging processes in pipes of different materials (high-density polyethylene (HDPE), polyvinyl chloride (PVC), polypropylene (PP), and polyethylene (PE)) were compared, and their correlation with the physicochemical properties was investigated. Results showed that the bio-clogging in HDPE and PVC pipes was more severe than that in PP and PE pipes. In bio-clogging development, the predominant factor changed from the surface roughness to the electron donator parameter (γ-). In the initial phase, the most severe bio-clogging was observed in the HDPE pipe, which exhibited the highest roughness (432 ± 76 nm). In the later phase, the highest γ- (2.2 mJ/m2) and protein content (2623.1 ± 33.2 µg/cm2) were observed in the PVC simultaneously. Moreover, the interaction energy indicated that the bacteria could irreversibly and reversibly adhere to the HDPE, whereas irreversible adhesion was observed in the PVC, PP, and PE cases. The findings clarify the thermodynamic mechanism underlying bio-clogging behaviors and provide novel insights into the bio-clogging behaviors in pipes of different materials, which can facilitate the development of effective bio-clogging control strategies.


Assuntos
Cloreto de Polivinila , Abastecimento de Água , Polietileno/química , Polipropilenos , Cloreto de Polivinila/química , Termodinâmica
7.
Polymers (Basel) ; 14(8)2022 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-35458330

RESUMO

The polymer industry is pushed to present solutions that lead to a circular plastics economy. High plastic packaging waste recycling targets will eventually lead to a high availability of packaging material recyclates. Although the use of polyethylene terephthalate (PET) recyclates is prescribed by regulations to be used in new PET bottles, no such regulation prescribes the use of polyethylene recyclate (rPE) in new products. One possibility of using rPE, which is considered by the European Union, is the use within pipe materials. Pipe applications demand a certain property profile, most prominently a high slow crack growth (SCG) resistance, which is not met by most packaging materials or recyclates made from it. Hence, this work investigates the use of commercially available post-consumer recyclates out of high-density polyethylene from packaging applications in compounds together with high SCG-resistant virgin PE pipe material with a PE100-RC specification. Two rPEs were acquired from German producers and blended to compounds consisting of 25 m%, 50 m% and 75 m% recyclate. These compounds, together with the pure recyclates and several virgin pipe materials acting as benchmarks were tested in terms of short- and long-term mechanical performance and with other basic characterization methods. Several compounds exceeded the performance of one tested virgin PE pipe material, an injection molding PE80 grade, in several categories. The content of recyclate needed to outperform this benchmark grade was mostly dependent on the resulting melt flow rate (MFR) of the compound and thus also of the MFR of the pure recyclate. Furthermore, different levels of polypropylene contaminations within the recyclates resulted in differently contaminated compounds. This is proved to influence the SCG resistance too, as compounds of similar MFRs but with different SCG resistances were found.

8.
Environ Pollut ; 296: 118758, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34968618

RESUMO

Microplastics (MPs) are detected in drinking water and plastic used during water treatment and distribution is one of the possible sources of MPs. This work aimed to investigate the MPs release behavior from ozone-exposed plastic pipe materials. The changes on physicochemical properties of the plastic materials were analyzed. The carbonyl groups introduction, the oxidation induction time variation, and the surface topography altering were detected after ozone exposure. The MPs release behavior varied between different plastic materials. As the ozone exposure duration of plastic materials prolonged, the released MPs abundance from the materials sharply increased, especially for LDPE, HDPE and PP. PVC was an exception where the released MPs abundance had little changes (p > 0.05). The total released MPs concentration from 20 h-aged samples could be ranked in order as follows: LDPE (656 ± 20 MP L-1) > PP (349 ± 20 MP L-1) > HDPE (337 ± 22 MP L-1) > PVC (63 ± 13 MP L-1). MPs release behavior was more likely to occur for LDPE, which was possibly related to the low oxidation resistance and weak stability of LDPE under ozone exposure. There was a more dominant contribution to MPs abundance increase caused by MPs release from aged plastic pipe materials than secondary MPs generation from original plastic particles. The generated MPs from 20 h-aged LDPE, HDPE, and PP accounted for 88.4%, 82.2%, and 88.3% of the total released MPs, respectively. For ozone-exposed plastic materials, the surface crack propagation and fragmentation posed an entry point for MPs generation. The proportion of generated MPs with polymer composition consistent with pipe materials (PE/PP) increased as the ozone exposure proceeded. Small-sized particles, especially 1-10 µm, were released more predominantly. This study provides an implication that possible MPs release from long-term aged plastic pipe materials under proper conditions could not be ignored.


Assuntos
Ozônio , Poluentes Químicos da Água , Microplásticos , Plásticos , Reprodução , Poluentes Químicos da Água/análise
9.
Sci Total Environ ; 774: 145113, 2021 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-33610999

RESUMO

Antibiotic resistance and biodiversity were investigated in microbial communities attached to inner surfaces of water supply fittings in a chlorinated drinking water distribution system (DWDS) supplied by two independent water treatment plants (WTPs) drawing the same source water. The investigation of the effect of the season, the applied water treatment technology, and type, material, and age of water supply fittings on both antibiotic resistance and biodiversity in biofilms involved collection of tubercles during summer and winter seasons throughout the DWDS. A total of 16 samples were collected (8 per season) from areas supplied by two independent WTPs. Culturable aerobic antibiotic resistant bacteria (ARB) proved more prevalent in summer. Various antibiotic resistance genes (ARGs) were detected, confirming the role of biofilms as ARGs reservoirs, but the abundances of quantified genes (sulI, ermB, qacEΔ1, intI1) were low (a range of

Assuntos
Água Potável , Microbiota , Antagonistas de Receptores de Angiotensina , Inibidores da Enzima Conversora de Angiotensina , Biodiversidade , Biofilmes , Água Potável/análise , Resistência Microbiana a Medicamentos/genética , Abastecimento de Água
10.
Water Res ; 194: 116922, 2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33640751

RESUMO

Biodegradable compounds can cause undesired microbial growth in drinking water systems and these compounds can originate from the water or pipe materials used in drinking water systems. The aim of our study was to determine the influence of different pipe materials on the microbial populations in water and biofilm under semi-stagnant conditions. The microbial communities in biofilm and water, which were in contact with seven different materials, were characterized by determining ATP concentrations, microbial composition gene copy numbers of some specific microbial groups. The ATP concentration in water and biofilm varied between the different materials with glass (negative control) < copper < PVCC < PE-Xc < PE-Xb < PE-100 < PVC-P. Gene copy numbers of Legionella spp., Mycobacterium spp., Pseudomonas spp., Aeromonas spp., fungi and Vermamoeba vermiformis were also higher for PVC-P and PE than for glass, copper and PVCC. The bacterial community composition in water and biofilm varied between materials as well. PERMANOVA and CAP analysis demonstrated that copper and PVC-P are different when compared to the other materials. Furthermore, bacterial community composition and ATP concentrations in water and biofilm were similar after eight and 16 weeks incubation, but differed from results obtained after one week. Finally, the ATP, the specific microbial groups and the bacterial community composition also differed between water and biofilm on each material. We conclude from our study that pipe material is an important factor that influences the biomass concentration, abundance of specific microorganisms and the bacterial community composition in distribution systems with unchlorinated drinking water.


Assuntos
Água Potável , Microbiota , Biofilmes , Microbiologia da Água , Abastecimento de Água
11.
Sci Total Environ ; 767: 144364, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33429277

RESUMO

This study aimed to explore the dynamics of microbial communities and antibiotic resistance genes (ARGs) during biofilm formation on polypropylene random (PPR), polyvinyl chloride and stainless steel pipes in domestic hot water system (DHWS), as well as their interactions. Full-scale classification was used to divide abundant and rare genera with 0.1% and 1% as the thresholds. The biofilm community structure presented a temporal pattern, which was mainly determined by conditionally rare or abundant taxa (CRAT) and conditionally rare taxa (CRT). The dynamics of microbial community during biofilm formation were observed, and the effect of pipe material on conditionally abundant taxa (CAT) and CRAT was greater than CRT and rare taxa (RT). CRAT showed the most complex internal associations and were identified as the core taxa. Notably, CRT and RT with low relative abundance, also played an important role in the network. For potential pathogens, 17 genera were identified in this study, and their total relative abundance was the highest (3.6-28.9%) in PPR samples. Enterococcus of CRAT was the dominant potential pathogen in young biofilms. There were 36 more co-exclusion patterns (140) observed between potential pathogens and nonpathogenic bacteria than co-occurrence (104). A total of 38 ARGs were predicted, and 109 negative and 165 positive correlations were detected between them. Some potential pathogens (Escherichia/Shigella and Burkholderia) and nonpathogenic bacteria (Meiothermus and Sphingopyxis) were identified as the possible hosts of ARGs. This study is helpful for a comprehensive understanding of the biofilm microbial community and ARGs, and provides a reference for the management and biosafety guarantee of newly-built DHWS.


Assuntos
Antibacterianos , Microbiota , Biofilmes , Resistência Microbiana a Medicamentos/genética , Genes Bacterianos , Água
12.
Environ Sci Pollut Res Int ; 28(1): 494-502, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32813133

RESUMO

Landfill leachate, due to its quantity and inherent risk, is generally collected and transported by piping system for advanced treatment. During the piping, the pipe materials may react with leachate, resulting in corrosion and scaling. In order to reduce possible failures and mitigate the associated consequences, this study provides an indicator system for material selection to aid the pipe system design. The material functional, economic, and environmental attributes are incorporated into the indicator system, to perform a precise selection of commercial drainage pipe materials, thus improving empirically oriented selection. Four common drainage pipe materials including high-density polyethylene (HDPE), polyvinyl chloride (PVC), galvanized steel, and seamless steel are taken as the material alternatives for the selection. Based upon their experimental data, a grey target decision-making framework is employed to perform the priority ranking of the materials. The results indicate that HDPE has the best performance, followed by PVC, galvanized steel, and seamless steel. This study discusses the validity of the selection results and the applicability of the proposed method, to provide insight into  leachate piping system design.


Assuntos
Eliminação de Resíduos , Poluentes Químicos da Água , Corrosão , Polietileno , Cloreto de Polivinila , Poluentes Químicos da Água/análise
13.
Water Environ Res ; 92(12): 2155-2167, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32621531

RESUMO

The aim of the study is to estimate the effectiveness of three antibiofilm agents against Escherichia coli biofilm that formed in six different types of pipelines. A laboratory-scale water system was built for this work to allow for the creation of biofilm in the pipelines studied. The level of the growth rate of E. coli biofilm cells was monitored over 90 days on those tested pipe materials. The results of bacterial cell densities displayed that the highest biofilm growth was observed in the biofilm formed on the iron (Fe) pipe. In contrast, the biofilm formation rate was significantly lower on copper (Cu) pipe compared to other materials. Three antibiofilm agents, including chlorine, silver ions (Ag+ ), and silver nanoparticles (AgNPs), were employed to eradicate the biofilm cells. E. coli counts indicated that AgNPs are more efficient in destructing any formed biofilm cells on all tested materials. At the same time, the chlorine was only useful in the case of biofilm developed on plastic and Cu. However, the antibiofilm efficiency of Ag+ performs similarly to chlorine against E. coli biofilm cells. Ultimately, AgNPs are considred the most powerful antibiofilm agent among the other agents toward the biofilm cells in their maturation stage, which offers an encouraging way for the long-term functioning of water systems. PRACTITIONER POINTS: The growth rate of E. coli biofilm cells was investigated on different materials. The count of biofilm cells developed on iron pipes was higher than other materials. The E. coli biofilm on iron pipe could resist chlorine and AgNPs to a large extent. The developed biofilm on copper pipe was more sensitive to chlorine, Ag+ . and AgNPs. The biofilm cells could be easily eradicated from plastic-based materials with all tested disinfectants.


Assuntos
Água Potável , Nanopartículas Metálicas , Biofilmes , Cloro/farmacologia , Escherichia coli , Prata/farmacologia , Abastecimento de Água
14.
Water Res ; 106: 593-603, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27776308

RESUMO

Interaction between old, corroded iron pipe surfaces and bulk water is crucial to the water quality protection in drinking water distribution systems (WDS). Iron released from corrosion products will deteriorate water quality and lead to red water. This study attempted to understand the effects of pipe materials on corrosion scale characteristics and water quality variations in WDS. A more than 20-year-old hybrid pipe section assembled of unlined cast iron pipe (UCIP) and galvanized iron pipe (GIP) was selected to investigate physico-chemical characteristics of corrosion scales and their effects on water quality variations. Scanning Electron Microscope (SEM), Energy Dispersive X-ray Spectroscopy (EDS), Inductively Coupled Plasma (ICP) and X-ray Diffraction (XRD) were used to analyze micromorphology and chemical composition of corrosion scales. In bench testing, water quality parameters, such as pH, dissolved oxygen (DO), oxidation reduction potential (ORP), alkalinity, conductivity, turbidity, color, Fe2+, Fe3+ and Zn2+, were determined. Scale analysis and bench-scale testing results demonstrated a significant effect of pipe materials on scale characteristics and thereby water quality variations in WDS. Characteristics of corrosion scales sampled from different pipe segments show obvious differences, both in physical and chemical aspects. Corrosion scales were found highly amorphous. Thanks to the protection of zinc coatings, GIP system was identified as the best water quality stability, in spite of high zinc release potential. It is deduced that the complicated composition of corrosion scales and structural break by the weld result in the diminished water quality stability in HP system. Measurement results showed that iron is released mainly in ferric particulate form.


Assuntos
Água Potável/química , Ferro/química , Corrosão , Qualidade da Água , Abastecimento de Água
15.
Appl Microbiol Biotechnol ; 99(24): 10713-24, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26311220

RESUMO

Biofilms in drinking water distribution systems (DWDSs) could cause several types of problems, such as the deterioration of water quality, corrosion of pipe walls, and potential proliferation of opportunistic pathogens. In this study, ten biofilm samples from different pipe materials, including ductile cast iron pipe (DCIP), gray cast iron pipe (GCIP), galvanized steel pipe (GSP), stainless steel clad pipe (SSCP), and polyvinyl chloride (PVC), were collected from an actual DWDS to investigate the effect of pipe material on bacterial community. Real-time quantitative polymerase chain reaction (qPCR) and culture-based method were used to quantify bacteria. 454 pyrosequencing was used for bacterial community analysis. The results showed that the numbers of total bacteria and culturable heterotrophic bacteria from iron pipes were higher than that in PVC, while the numbers of Shigella and vibrios were low in biofilms from iron pipes. Bacterial community analysis showed that Hyphomicrobium or Desulfovibrio were the predominant microorganism in iron pipes, whereas Sphingomonas or Pseudomonas were dominant in other types of pipe. This study revealed differences in bacterial communities in biofilms among different pipe materials, and the results were useful for pipeline material selection in DWDSs.


Assuntos
Bactérias/classificação , Biofilmes/crescimento & desenvolvimento , Biota , Água Potável , Microbiologia Ambiental , Bactérias/genética , China , Cidades , Reação em Cadeia da Polimerase em Tempo Real
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA